1 PharmaReady Version 6.0 Installation Qualification Client Workstation Document Number: PR-IQ-002 Doc Version 3.2, 24 th July 2017 Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing Signature / Date

2 TABLE OF CONTENTS 1. Objective Prerequisite Installation System Description Procedure Execution Protocol Completion Acceptance Criteria Document Control Revision History Pre-IQ Approval from Customer: IQ Roles and Responsibilities: Execution/Review Signature Verification PharmaReady Client Workstation Hardware Client Workstation Web Browser Settings Verification Supporting Softwares Installation Verification PharmaReady In-Place Editing Installation Verification POST-EXECUTION APPROVAL Protocol Deviation Report Page 2 of 17

3 1. OBJECTIVE This protocol outlines the requirements for the Installation Qualification (IQ) for software that needs to be installed on the PharmaReady client workstation(s) for the PharmaReady version 6.0. Successful completion of this protocol will provide assurance that the software is installed on the workstations in accordance with applicable manufacturer s recommendations. This protocol is a part of the overall validation effort for PharmaReady version 6.0 and will be used with the Operational Qualifications (OQ). IQ s and/or OQ s may be developed by the customer and in lieu of or in conjunction with the manufacturer s documents Prerequisite Installation This IQ presumes the Client workstation has been configured with a running version of Microsoft Windows (as specified below) and that the web browser to be used has been installed during the installation of Windows or by a later upgrade. 2. SYSTEM DESCRIPTION The PharmaReady software requires a client workstation which meets the following software and hardware prerequisites: Hardware: Software: Display: VGA, Super VGA, compatible with Windows Mouse: Microsoft Mouse or equivalent Other Devices: Fast Ethernet NIC Connection to the client s Intranet for internal access or secure method for accessing the PharmaReady server via the public Internet, VPN, or other access methodology. Microsoft Windows NT, 2000, Windows 7or XP Professional operating system. Internet Explorer version 8.0 and above Internet Explorer for Mac v5.2.3 (for client workstations using Apple hardware) Microsoft Office any version or other application tools that would be required to author and view documents stored in PharmaReady. Adobe Acrobat Standard / Professional any version (for ectd bookmarks and hyperlinks) (Applicable for ectd Module only) Adobe Reader any version that would be required to view the PDF documents published by PharmaReady. Page 3 of 17

4 3. PROCEDURE 3.1. Execution The customer will determine if the Installation Qualification is necessary. If necessary, NAVITAS LLP or the customer will execute the Installation Qualification at the customer location (onsite installs only). Print the Installation Qualification document. Follow the instructions for each table in this document. Document all results, reviews, verifications, and screen shots at the time they are. All screen prints must be created in a single MS Word document IQ Client Screen Capture Document. The IQ Client Screen Capture Document will be labeled with the following information: o Header contains: Project Name Version# Operational Qualification Script Name o Each Picture in Screen Capture Document OQ Script Step # above or below picture o Each Page of Screen Capture Document Validation Consultants Initials Executed Date Assemble IQ Client Screen Capture Document to the back of the applicable OQ Script Step. Validation Consultant The Validation Consultant writes their name in the Executed by field at the beginning of each section. The Validation Consultant enters Pass or Fail in the Observed Results As Expected column. If the expected results are not as expected write a deviation report. The Validation Consultant should write a deviation report when: o The protocol step is inaccurate. o The data is entered incorrectly. o A screen shot was not taken for a required step. The Validation Consultant enters their initials and the date in the Executed & Verified By/ Date column to indicate an acceptable result. The Validation Consultant will label each screen print with the section identified, corresponding to results. Verifier The Verifier verifies the execution of the IQ Client and ensures all screen captures reflect the correct data. The Verifier reviews the documentation to ensure all sections are completed. The Verifier writes their name in the verified by field at the beginning of each section. The verifier will sign in the Executed & Verified By Date column for each section. The verifier will be the witness while Validation Consultant executes the protocol.(verifier can be either from NAVITAS LLP end or customer end). Page 4 of 17

5 Reviewer The Customer QA/Regulatory will review the documentation to ensure all sections are completed and writes their name in the reviewed by field at the end of each section. The Reviewer reviews the documentation to ensure all sections are completed Protocol Completion After completing the execution of the IQ Client, NAVITAS LLP will retain a photocopy of the completed IQ document and all supporting documentation for support purposes. NAVITAS LLP will provide original IQ documents to the customer. After completing the execution of the IQ Client, submit the completed protocol with supporting data and all deviation reports to the Quality Assurance Director / Manager Acceptance Criteria Criteria for accepting the IQ Client phase as being complete are: o The IQ document has been and all screen captures are printed, labeled, initialed, and dated. o Any deviations encountered have a corresponding deviation report that is corrected or resolved. o The IQ document has been verified by a witness. o The IQ document has been reviewed by quality assurance or designee. o The IQ document has been approved by the customer. Approver The Customer QA/Regulatory/Project Manager will approve the documentation to ensure all sections are completed and write their name in the Post-Execution Approval table at the end of the protocol. Approval of the DMS Admin IQ indicates that the criteria outlined in this protocol have been met and indicates acceptance of the system. 4. DOCUMENT CONTROL Authored by: Reviewed by: Approved by: Janani S Validation Engineer Date 19-Jun Gopi T Validation Lead Date 23-Jun 2017 Vijay Srinivasan, Associate Program Manager- PharmaReady Date 24-Jul Page 5 of 17

6 5. REVISION HISTORY Version Date Author Remarks April 2009 Edwin Rodriguez Initial finalized version for Oct 2009 Edwin Rodriguez Initial finalized version for Jan 2012 Baskar Initial finalized version for May2012 Baskar Jan 2013 Baskar Initial Version for 5.1 Removed Settings which are not applicable for MS Office Nov 2014 Ashok John Finalized the OQ as per the 6.0 release April 2015 Ashok John Updated the verifier role Jun-2017 Janani S Updated the script errors as per validation team review comments and added Evidence Ref.# column to map the Evidence report 6. PRE-IQ APPROVAL FROM CUSTOMER: The signatures below indicate approval of this IQ for execution by authorized customer staff. Name/Title Signature Date Page 6 of 17

7 7. IQ ROLES AND RESPONSIBILITIES: Indicate each person s responsibility in the installation qualification protocol process. Name Title Role (Validation Consultant, Verifier, Reviewer, Approver) 8. EXECUTION/REVIEW SIGNATURE VERIFICATION Instructions: All personnel assigned to execute or review this protocol, attached exceptions and/or supporting documentation must sign and initial in the space provided below. Printed Name Signature and Initials Affiliation Page 7 of 17

8 9. PHARMAREADY CLIENT WORKSTATION HARDWARE Instructions: Provide information for all the hardware associated with the PharmaReady Client Workstation(s). Include manufacturer, model numbers, capacity, and ratings. This form may be reproduced as necessary. Executed by: Date: Verified by: Date: 9.1 Client Workstation Feature Value Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/Date Manufacturer / Model No. Serial Number CPU Processor RAM Total Disk Space Client Machine Name Display Resolution Comments: Reviewed By: Date: Page 8 of 17

9 10. WEB BROWSER SETTINGS VERIFICATION Instructions: It is assumed the web browser software has been installed on the client workstation. Follow the instructions below to verify the proper installation and configuration and note any discrepancies in the Comments space provided. Executed by: Verified by: Date: Date: Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date On the client workstation, open the Internet Explorer web browser by clicking on the Desktop shortcut or through the Start menu option. Select Help About Internet Explorer from the main menu. Verify that the displayed browser Version and Update Versions are as required for PharmaReady (IE 8 and above). The browser Version and Update Versions are in the list of supported versions Open Internet Explorer Tools Internet Options Under General Tab, Click on Settings within Browsing History, Under Temporary Internet Files, Ensure the first option (Every time I visit the Webpage) is selected. (Applicable for ectd module Only) Security Settings are changed. Page 9 of 17

10 Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date Select Tools Options from the main menu. When the Internet Options window opens, select the Security tab. Add PharmaReady application web address into Trusted Sites Add file://pharmareadyservername into Trusted Sites PharmaReady application web address is added to Trusted Sites Select Tools Options from the main menu. When the Internet Options window opens, select the Privacy tab. Add PharmaReady application web address into Pop-Up Blocker allowed list. PharmaReady application web address is added to Popup blocker allowed list. Page 10 of 17

11 Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date Open Internet Explorer Tools Internet Options Click the Security tab Select Trusted Sites Click Custom Level Ensure the following are set to Enable o Allow previously unused ActiveX controls to run without prompt o Allow scriptlets o Automatic prompting for ActiveX controls o Binary and script behaviours o Active Scripting, o Automatic Prompting for File Download (Not Applicable for versions above IE 8) o File Download o Access data sources across domains (Applicable for ectd and SPL modules Only) Security Settings are changed Open Internet Explorer (Applicable for ectd and SPL modules only) Tools Internet Options Click the Security tab Select Internet Click Custom Level Ensure Access data sources across domain is set to Enable Security Settings are changed. Page 11 of 17

12 Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date From your Internet Explorer version 11 window, Go to Settings -> Compatible view settings. The compatible view settings window will get open. In "add this website" field, type the PharmaReady URL (for e.g. ) and click add. The PharmaReady URL will be added in the box "websites you've added to the compatibility view" successfully Ensure checkbox is ticked for below two options. Display all websites in compatibility view Display intranet sites in compatibility view Compatibility view settings are changed. Comments: Reviewed By: Date: Page 12 of 17

13 11. SUPPORTING SOFTWARES INSTALLATION VERIFICATION Instructions: It is assumed the Microsoft office, Adobe Reader and Adobe Acrobat has been installed on the client machine by the IT team at Customer location. Follow the instructions below to verify the proper installation and ask the IT team to install if not done already. Executed by: Verified by: Date: Date: Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date On the client workstation, install Microsoft office and ensure Word, Excel, PowerPoint features are enabled. Note: Excel and Power Point features is optional while executing in server. Result: Microsoft Office was installed in Client machine On the client workstation, install Adobe Reader. Result: Adobe Reader is installed in Client machine. Comments: Reviewed By: Date: Page 13 of 17

14 12. PHARMAREADY IN-PLACE EDITING INSTALLATION VERIFICATION Instructions: Only necessary for client workstations that will be using the DMS In-Place Editing options for editing Office documents within PharmaReady. Complete the steps to allow the DMS In-Place Editing functionality to work on the PharmaReady Client as instructed below and note any discrepancies in the Comments space provided. This is applicable only for PharmaReady DMS installations. Executed by: Verified by: Date: Date: Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date Obtain a copy of OfficeFrame.ocx (originally supplied in the OfficeFrame folder on the 6.0 Install Disk) Copy it to a folder on the client machine (recommended c:\windows\system32 for 32bit OS and c:\windows\ SysWoW64 for 64 bit OS). Open the command prompt and type Regsvr32 c:\windows\system32\officeframe.ocx A pop-up message will appear stating OfficeFrame.ocx file is registered on this machine. Page 14 of 17

15 Operation Are Observed Results As Expected? (Note Any Discrepancies) Evidence Ref. # Executed & Verified By/ Date Open Internet Explorer Tools Internet Options Click the Security tab Select Trusted Sites Click Custom Level Ensure the following are set to Enable o Initialize and script ActiveX controls not marked as safe o Run ActiveX controls and plug-ins o Script ActiveX controls marked safe for scripting Ensure the following are set to Prompt o Download unsigned ActiveX controls If your system has this option, ensure it is set to Enable o Run components not signed with Authenticode Click OK A popup message appears asking are you sure you want to change the security settings for this zone? o Click Yes Security settings are changed. Comments: Reviewed By: Date: Page 15 of 17

16 13. POST-EXECUTION APPROVAL The signatures below indicate approval of this Executed protocol by Navitas LLP. Name Signature Company Date Page 16 of 17

17 14. PROTOCOL DEVIATION REPORT Print as many copies of this page as necessary. Describe each Deviation on a separate page. Number: Date: Protocol Section: Step #: Deviation: Initiator: Date: Corrective Action: Reviewed By: Date: Page 17 of 17

Company Name: Address: Project Name: Server Name: Server Location:

Company Name: Address: Project Name: Server Name: Server Location: PharmaReady Version 6.0 Installation Qualification Tenant Setup Document Number: IQ39 Doc Version 1.1, 15 th Jan 2018 Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By:

More information

Release Date: 6 th January Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing

Release Date: 6 th January Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing PharmaReady SPL Import Utility Version 1.1 Installation Qualification SPL Import Utility Release Date: 6 th January 2014 Document Number:SIQ01 Version 1.1, 12 th June 2014 Company Name: Address: Project

More information

Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing

Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing Signature / Date Document Release date 10 th June 2013 Page 1 of 18 Contents 1. Objective...

More information

Document Version th November Company Name: Address: Project Name: Server Name: Server Location:

Document Version th November Company Name: Address: Project Name: Server Name: Server Location: Company Name: Address: Project Name: Server Name: Server Location: IQ Prepared By: Name / Title / Representing Signature / Date Document Release date 18 th November 2013 Page 1 of 20 Contents 1. Objective...

More information

PharmaReady Version 5.1 SPL Workflow Operational Qualification Complete Installation Software Release Date 28 Jan 2013

PharmaReady Version 5.1 SPL Workflow Operational Qualification Complete Installation Software Release Date 28 Jan 2013 PharmaReady Version 5.1 SPL Workflow al Qualification Complete Installation Software Release Date 28 Jan 2013 Doc Version 1.0 Jan 28, 2013 Company Name: Address: Project Name: Server Name: Server Location:

More information

Item Version Remark pp.

Item Version Remark pp. 1. Recommended PC Settings 1/16 Item Version Remark pp. OS Windows7 (32/64bit) Windows10 (32/64bit) Display the IE (Windows10 user only) Set to IE a browser that usually use.(only if necessary) 1,2,3 4,5,6

More information

Training Quick Steps Internet Explorer (v7) Settings. Adding Your URL as a Trusted Site

Training Quick Steps Internet Explorer (v7) Settings. Adding Your URL as a Trusted Site Adding Your URL as a Trusted Site In order to access PrognoCIS, you must add your URL as a Trusted Site, which will enable the Security Certificate to allow you to access the secured web site. Refer to

More information

Ministry of Education EFIS User Set Up Guide Version 1.9

Ministry of Education EFIS User Set Up Guide Version 1.9 Ministry of Education EFIS 2.0 - User Set Up Guide Version 1.9 August 22, 2016 1 Table of Contents 1 Table of Contents... 2 2 Document History... 3 3 Description and System Requirements... 4 3.1 Description...

More information

QuestionPoint chat The Guide to IE browser setup Last updated: 2013 Nov 12

QuestionPoint chat The Guide to IE browser setup Last updated: 2013 Nov 12 QuestionPoint chat The Guide to IE browser setup Last updated: 2013 Nov 12 This guide provides a procedure for initially configuring your Internet Explorer (IE) browser to use Flash Chat. Please note that

More information

Onesource Dataflow. Data Provider Guide. Tax & Accounting. Last updated May 2012

Onesource Dataflow. Data Provider Guide. Tax & Accounting. Last updated May 2012 Onesource Dataflow Data Provider Guide Last updated May 2012 Tax & Accounting Copyright 2012 Thomson Reuters/ONESOURCE. All Rights Reserved. Proprietary Materials No use of these Proprietary materials

More information

ValuePRO Tutorial Internet Explorer 8 Configuration

ValuePRO Tutorial Internet Explorer 8 Configuration ValuePRO Tutorial Internet Explorer 8 Configuration Table of Contents Contents 1. Adding ValuePRO to Trusted Sites... 1 1. Overview... 1 2. Changes Required... 1 2. Enabling Cross Site Scripting... 3 1.

More information

PROCON CONTRACTOR USERS BROWSER SETUP

PROCON CONTRACTOR USERS BROWSER SETUP PROCON CONTRACTOR USERS BROWSER SETUP PP1019-09 / Jan. 2018 AVEVA Solutions Limited High Cross Madingley Road Cambridge CB3 0HB Tel +44 (0)1223 556655 Fax +44 (0)1223 556666 aveva.com PROCON CONTRACTOR

More information

QuestionPoint chat The Guide to IE browser setup Last updated: 2009 June 23

QuestionPoint chat The Guide to IE browser setup Last updated: 2009 June 23 QuestionPoint chat The Guide to IE browser setup Last updated: 2009 June 23 This guide provides a procedure for initially configuring your Internet Explorer (IE) browser to use Flash Chat. Note: If you

More information

PRE-REQUISITES. The following software are the pre-requisites for functioning of SRM.

PRE-REQUISITES. The following software are the pre-requisites for functioning of SRM. PRE-REQUISITES A. SOFTWARE The following software are the pre-requisites for functioning of SRM. Recommended OS: Windows 7 SP1 and above. Note: (Windows XP is not recommended) Recommended Browser: Internet

More information

PROCON COMPANY USERS BROWSER SETUP

PROCON COMPANY USERS BROWSER SETUP PROCON COMPANY USERS BROWSER SETUP PP1018-08 / Nov. 2017 AVEVA Solutions Limited High Cross Madingley Road Cambridge CB3 0HB Tel +44 (0)1223 556655 Fax +44 (0)1223 556666 aveva.com PROCON COMPANY USERS

More information

Workstation Configuration Guide

Workstation Configuration Guide Workstation Configuration Guide August 13, 2018 Version 9.6.134.78 For the most recent version of this document, visit our documentation website. Table of Contents 1 Workstation configuration 4 1.1 Considerations

More information

Settings for UPlan PC Users

Settings for UPlan PC Users UPlan operates best with certain browser and screen resolution settings. This job aid will walk you through how to set these. I. UPlan IE 11 Settings (page 1) II. UPlan Firefox Settings (page 4) III. Firefox

More information

Workstation Configuration

Workstation Configuration Workstation Configuration December 15, 2017 - Version 9.3 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

Workstation Configuration

Workstation Configuration Workstation Configuration December 12, 2017 - Version 9.4 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

PLATO Learning Environment (v2.0) System and Configuration Requirements

PLATO Learning Environment (v2.0) System and Configuration Requirements PLATO Learning Environment (v2.0) System and Configuration Requirements For Workstations July 30, 2010 Windows XP Home and Professional (SP3) Windows Vista Home/Premium/Business/Ultimate Windows 7 Home/Premium/Business/Ultimate

More information

Work instructions for US-FDA ANDA Submissions Work Instructions for ectd US-FDA ANDA Submissions

Work instructions for US-FDA ANDA Submissions Work Instructions for ectd US-FDA ANDA Submissions Work Instructions for ectd US-FDA ANDA Submissions 1. Logon to the PharmaReady ectd System Work instructions for US-FDA ANDA Submissions PharmaReady is a Web-based application. The logon screen and all

More information

Hardware/Software Specifications for Self-Hosted Systems (Single Server)

Hardware/Software Specifications for Self-Hosted Systems (Single Server) Hardware/Software Specifications for Self-Hosted Systems (Single Server) EBIX, INC. 1 Ebix Way, Johns Creek, GA 30097 Rev. 08/2017 2016 Ebix, Inc. and its subsidiaries. All Rights Reserved. This software

More information

SAM Assessment, Training and Projects for Microsoft Office

SAM Assessment, Training and Projects for Microsoft Office SAM Assessment, Training and Projects for Microsoft Office December 2015 System Requirements Contents Overview 2 Introduction 2 System Requirements 3 Workstation Requirements 3 Setting Up SAM Workstations

More information

PROCON CONTRACTOR USERS BROWSER SETUP

PROCON CONTRACTOR USERS BROWSER SETUP PROCON CONTRACTOR USERS BROWSER SETUP PP1019-07 / Aug. 2017 AVEVA Solutions Limited High Cross Madingley Road Cambridge CB3 0HB Tel +44 (0)1223 556655 Fax +44 (0)1223 556666 aveva.com PROCON CONTRACTOR

More information

Workstation Configuration

Workstation Configuration Workstation Configuration September 22, 2015 - Version 9 & 9.1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

Go! Res & IE 7 Install FAQ & Support Document. Go! Res & IE 7 Install FAQ & Support Document Table of Contents

Go! Res & IE 7 Install FAQ & Support Document. Go! Res & IE 7 Install FAQ & Support Document Table of Contents Go! Res & IE 7 Install FAQ & Support Document Go! Res & IE 7 Install FAQ & Support Document Table of Contents I. Go! Res & Internet Explorer 7 Notes & Minimum Requirements 1 1. Internet Explorer 7 System

More information

Browser Configuration Reference

Browser Configuration Reference Sitecore CMS 7.0 or later Browser Configuration Reference Rev: 2013-09-30 Sitecore CMS 7.0 or later Browser Configuration Reference Optimizing Internet Explorer and other web browsers to work with Sitecore

More information

PLATO Learning Environment System and Configuration Requirements

PLATO Learning Environment System and Configuration Requirements PLATO Learning Environment System and Configuration Requirements For Workstations December 13, 2010 1 Content About This Document... 3 Document Change Log... 4 System & Configuration Requirements... 5

More information

1 Post-Installation Configuration Tasks

1 Post-Installation Configuration Tasks 1 Post-Installation Configuration Tasks 1.1 Overview The previous chapters provide instructions on how to set up Appeon system architecture, including installing Appeon for PowerBuilder components, as

More information

Recommended Browser Settings

Recommended Browser Settings Recommended Browser Settings August 2015 This document is intended for restricted use only. Infinite Campus asserts that this document contains proprietary information that would give our competitors undue

More information

IS-DM320, HB User Manual. Ver 1.0

IS-DM320, HB User Manual. Ver 1.0 IS-DM320, HB User Manual Ver 1.0 Sentry360 2014 Table of Contents 1. Overview... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Dimensions... 5 1.4 Connectors... 6 2. Camera Cabling... 7 2.1 Connect

More information

Obtaining a login and password to the Online Application

Obtaining a login and password to the Online Application Obtaining a login and password to the Online Application You should have received a password to the online application from Regional Credentialing. If you ve forgotten your password, please contact us.

More information

Document Management System. for QC Postfunding Review

Document Management System. for QC Postfunding Review Document Management System for QC Postfunding Review Contents Quick Overview: How to Submit Documents to FM Processing... iii How to Log in to the Document Management System (DMS)... iv How to Search for

More information

etrac Guide System Requirements Global DMS, 1555 Bustard Road, Suite 300, Lansdale, PA , All Rights Reserved.

etrac Guide System Requirements Global DMS, 1555 Bustard Road, Suite 300, Lansdale, PA , All Rights Reserved. etrac Guide to System Requirements Version: 2.5 Published: 05/18/2015 Global DMS, 1555 Bustard Road, Suite 300, Lansdale, PA 19446 2015, All Rights Reserved. Table of Contents Minimum System Requirements...

More information

Purchasing Portal Supplier s technical requirements FULLSTEP PORTAL VS

Purchasing Portal Supplier s technical requirements FULLSTEP PORTAL VS Purchasing Portal Supplier s technical requirements FULLSTEP PORTAL VS. 31600 FULLSTEP NETWORKS 2008 Document services cap/ 26/02/2008 Table of Contents 1 Introduction 3 2 Requirements 3 2.1 Internet connection

More information

Hardware/Software Specifications for Ebix-Hosted Systems

Hardware/Software Specifications for Ebix-Hosted Systems Hardware/Software Specifications for Ebix-Hosted Systems EBIX, INC. 1 Ebix Way, Johns Creek, GA 30097 Rev. 06/2016 2016 Ebix, Inc. and its subsidiaries. All Rights Reserved. This software and documentation

More information

Data Warehouse: User Computer Configuration Guide

Data Warehouse: User Computer Configuration Guide University of Texas at San Antonio Data Warehouse: User Computer Configuration Guide Sponsored by the Vice Provost of Institutional Effectiveness DOCUMENT HISTORY This is an on-line document. Paper copies

More information

MLabs Connect: System Requirements

MLabs Connect: System Requirements Purpose MLabs Connect requires specific versions of Microsoft Windows and Internet Explorer in order to function properly. This document describes the required workstation configuration settings to be

More information

Amadeus Selling Platform Connect

Amadeus Selling Platform Connect Amadeus Selling Platform Connect Technical Requirements Index Page 2 of 13 _ Amadeus Selling Platform Connect Technical Requirements... 4 Internet Browser... 4 Transport Layer Security 1.2 (TLS)... 4 Browser

More information

Hardware/Software Specifications for Self-Hosted Systems (Multi-Server)

Hardware/Software Specifications for Self-Hosted Systems (Multi-Server) Hardware/Software Specifications for Self-Hosted Systems (Multi-Server) EBIX, INC. 1 Ebix Way, Johns Creek, GA 30097 Rev. 01/2016 2016 Ebix, Inc. and its subsidiaries. All Rights Reserved. This software

More information

CUTEPDF WRITER. Department of Information Technology User Support. Date October 2004

CUTEPDF WRITER. Department of Information Technology User Support. Date October 2004 CUTEPDF WRITER Department of Information Technology User Support Reference TRN1126 (OPL042) Revision 1.00 Date October 2004 This publication and any accompanying course materials are distributed for use

More information

IHS Enerdeq Browser Getting Started

IHS Enerdeq Browser Getting Started IHS > Critical Information Product IHS Enerdeq Browser Getting Started April 2013 2013 IHS, All Rights Reserved. All trademarks belong to IHS or it s affiliated and subsidiary companies, all rights reserved.

More information

Recommended Browser Settings

Recommended Browser Settings Recommended Browser Settings Internet Explorer Settings (PC) Mozilla Firefox Settings (PC) Mozilla Firefox Settings (Mac) Safari Settings (Mac) Chrome Settings (PC) Infinite Campus recommends modifying

More information

Policy Settings for Windows Server 2003 (including SP1) and Windows XP (including SP2)

Policy Settings for Windows Server 2003 (including SP1) and Windows XP (including SP2) Web 2 Policy Settings for (including SP1) and XP (including SP2) This document was written by Conan Kezema. and XP together introduce more than 270 new administrative template policy settings for you to

More information

CPD Online System Requirements and Browser Settings

CPD Online System Requirements and Browser Settings CPD Online System Requirements and Browser Settings Browser & Operating System Compatibility Matrix IE 11.0 1 Edge 1 Firefox 51 Chrome 56 Safari 8.0.7 Safari 9.1.2 Safari 10.0 Supported Operating Systems

More information

Web CCaR Login Troubleshooting Guide

Web CCaR Login Troubleshooting Guide Web CCaR Login Troubleshooting Guide Web CCaR Login Troubleshooting Guide ALTESS Implementation Copyright 2015 by Integrated Data Services, Inc. All rights reserved. No part of this copyrighted work may

More information

GESTAMP AUTOMOCION Purchasing Portal Supplier s technical requirements FULLSTEP PORTAL VS. 3.0.

GESTAMP AUTOMOCION Purchasing Portal Supplier s technical requirements FULLSTEP PORTAL VS. 3.0. GESTAMP AUTOMOCION Purchasing Portal Supplier s technical requirements FULLSTEP PORTAL VS. 3.0. FULLSTEP NETWORKS 2007 Document services cap/ 29/06/2007 Table of Contents 1 Introduction 3 2 Requirements

More information

KNOXPLANS for New Users

KNOXPLANS for New Users KNOXPLANS for New Users Welcome to KnoxPlans The City of Knoxville recommends that KnoxPlans (aka ProjectDox ) run on PC operating systems up to and including Windows 7 32-bit (Windows XP, Windows Vista,

More information

Lab - Configure Browser Settings in Windows 8

Lab - Configure Browser Settings in Windows 8 Introduction In this lab, you will configure browser settings in Microsoft Internet Explorer. Recommended Equipment A computer with Windows 8 An Internet connection Step 1: Set Internet Explorer as the

More information

OASIS Mobile Installation Guide

OASIS Mobile Installation Guide OASIS Mobile Installation Guide Table of Contents I. Preparation... 1 A. Verify System Requirements... 1 B. Uninstall Java... 3 C. Configure Internet Explorer... 3 II. Install OASIS Mobile... 5 III. Install

More information

AccuRoute Web Client v2.0 installation and configuration guide

AccuRoute Web Client v2.0 installation and configuration guide AccuRoute Web Client v2.0 installation and configuration guide July 22, 2009 Omtool, Ltd. 6 Riverside Drive Andover, MA 01810 Phone: +1/1 978 327 5700 Toll-free in the US: +1/1 800 886 7845 Fax: +1/1 978

More information

Insbridge Enterprise Rating RateManager Client Setup Document

Insbridge Enterprise Rating RateManager Client Setup Document Oracle Insurance Insbridge Enterprise Rating RateManager Client Setup Document Release 5.2.x July 2016 INTRODUCTION RateManager is a component within the Oracle Insurance Insbridge Enterprise Rating (Insbridge)

More information

Taking SAP Contact Center End-User Applications into Use

Taking SAP Contact Center End-User Applications into Use Last updated on: 18.05.2018 Responsible IPK Taking SAP Contact Center End-User Applications into Use Contents 1. Introduction... 3 1.1. Communication Desktop (CDT)... 3 Prerequisites... 3... 4 Limitations

More information

IS-BX-12 User Manual

IS-BX-12 User Manual IS-BX-12 User Manual Ver 1.0 Sentry360 2014 Table of Contents 1. Overview...3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Dimensions... 4 1.4 Connectors... 5 1.5 Light Sensor... 6 2. Camera Cabling...6

More information

System Requirements July 2017

System Requirements July 2017 System Requirements July 2017 Contents Overview to the SAM System Requirements Guide 3 Setting Up Your Computer 4 Workstation Requirements 4 Necessary Software 5 Disk Protection Software 5 Monitor Resolution

More information

Configure Internet Explorer for MyEvolv Overview

Configure Internet Explorer for MyEvolv Overview Configure Internet Explorer for MyEvolv Overview MyEvolv requires a specific browser setting configuration to ensure optimal performance. Incorrect browser settings will result in page loading issues and

More information

Optimal Global Procurement System. (KG-Pro) Login Manual

Optimal Global Procurement System. (KG-Pro) Login Manual Optimal Global Procurement System (KG-Pro) Login Manual Ver.1.1 Contents 1 Foreword... 2 2 Preparation for using KG-Pro... 2 2.1 Hardware... 2 2.2 Software... 2 2.3 User ID... 3 2.4 Required items for

More information

INTRODUCTION / COMPUTER & BROWSER SETTINGS / AGcat CLIENT

INTRODUCTION / COMPUTER & BROWSER SETTINGS / AGcat CLIENT INTRODUCTION / COMPUTER & BROWSER SETTINGS / AGcat CLIENT Each member of Library Management Network, Inc. (LMN) is responsible for cataloging their titles and adding items. The LMN Cataloging Procedural

More information

Using VPN. Provider Staff

Using VPN. Provider Staff Using VPN Provider Staff 1 Internet Explorer (32-bit) Enter https://vpn.djj.state.fl.us in the address bar You will need to use IE-32bit. 64-bit machines have the IE 64-bit option as well. To check this

More information

Workstation Configuration

Workstation Configuration Workstation Configuration Version 8.2 May 2, 2014 For the most recent version of this document, visit our documentation website. Table of Contents 1 Workstation configuration 3 1.1 Custom level Internet

More information

Symantec ediscovery Platform

Symantec ediscovery Platform Symantec ediscovery Platform Native Viewer (ActiveX) Installation Guide 7.1.5 Symantec ediscovery Platform : Native Viewer (ActiveX) Installation Guide The software described in this book is furnished

More information

Learning Center Computer and Security Settings

Learning Center Computer and Security Settings Learning Center Computer and Security Settings Learning Center Computer Settings Please Note: To allow your computer to communicate most effectively with the Learning Center, and update your training record

More information

Web Browser Settings Guide

Web Browser Settings Guide Web Browser Settings Guide Table of Contents Operating Systems and Browser Versions...2 Mozilla Firefox...2 Using Adobe Reader Instead of the FireFox PDF Viewer...4 Google Chrome...8 Google Chrome PDF

More information

MyNursingLab Installation Checklist and Troubleshooting Guide

MyNursingLab Installation Checklist and Troubleshooting Guide MyNursingLab Installation Checklist and Troubleshooting Guide Audience Overview This document is intended for users, computer lab administrators, field support personnel, and others responsible for installing

More information

PC Configuration v 6.6 (01 May 2009)

PC Configuration v 6.6 (01 May 2009) A I R M E D I N T E R N A T I O N A L I N T R A N E T D O C U M E N T A T I O N PC Configuration v 6.6 (01 May 2009) There are a variety of requirements and settings that should be made in order for the

More information

Client Installation Guide

Client Installation Guide Client Installation Guide Version 2.3 April 2014 Purpose of this document This document is designed to assist you in installing the RMS client onto your workstations. The RMS client needs to be installed

More information

POWER EGG2.0 Ver.2.5 Initial Manual (English version)

POWER EGG2.0 Ver.2.5 Initial Manual (English version) POWER EGG2.0 Ver.2.5 Initial Manual (English version) Copyright 2013 D-CIRCLE,INC. All Rights Reserved 2013.01 Introduction This document explains about the browser setup and login that are used in POWER

More information

Using VPN. DJJ Staff

Using VPN. DJJ Staff Using VPN DJJ Staff 1 Internet Explorer (32-bit) Enter https://vpn.djj.state.fl.us in the address bar You will need to use IE-32bit. 64-bit machines have the IE 64-bit option as well. To check this setting

More information

Configure Internet Explorer Version 10 Settings for CGM webpractice

Configure Internet Explorer Version 10 Settings for CGM webpractice Configure Internet Explorer Version 10 Settings for CGM webpractice 2 CompuGroup Medical US Configure IE v10 Settings for CGM webpractice Revised: 1.19.2017 Table of Contents About this Document... 3 Configuring

More information

usign 300 Color LCD Signature Capture Pad Plug In User Manual Rev A

usign 300 Color LCD Signature Capture Pad Plug In User Manual Rev A usign 300 Color LCD Signature Capture Pad Plug In User Manual 80109508-001 Rev A 1 Revision History Revision Date Description of Changes By 50 01/07/2014 Draft Eric Yang 51 06/11/2014 Add support for Word

More information

Configure Internet Explorer Version 11 Settings for CGM webpractice

Configure Internet Explorer Version 11 Settings for CGM webpractice Configure Internet Explorer Version 11 Settings for CGM webpractice 2 CompuGroup Medical US Configure IE v11 Settings for CGM webpractice Revised: 2.21.2018 Table of Contents About this Document... 3 Configuring

More information

IS-DM240, V User Manual. Ver 1.0

IS-DM240, V User Manual. Ver 1.0 IS-DM240, V User Manual Ver 1.0 Sentry360 2014 Table of Contents 1. Overview... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Dimensions... 6 1.4 Switch / Connector Definition... 7 2. Camera Cabling...

More information

CFS Browser Compatibility

CFS Browser Compatibility CFS Browser Compatibility This document outlines the requirements for browsers certified by Oracle, for use with our current version of CFS. The information contained here has been consolidated from documents

More information

OPERA V5 11G Workstation setup guide L A S T U P D A T E S E P T E M B E R

OPERA V5 11G Workstation setup guide L A S T U P D A T E S E P T E M B E R OPERA V5 11G Workstation setup guide L A S T U P D A T E S E P T E M B E R 2 0 1 7 Table of Contents Revision History 1 Workstation Operating System Requirement 2 On Each Workstations 2 Internet Explorer

More information

WorldNow Producer. Requirements Set-up

WorldNow Producer. Requirements Set-up WorldNow Producer Requirements Set-up Table of Contents Introduction... 3 1. System Requirements... 3 2. Set-up Producer URL as a 'Trusted Site' (Internet Explorer only)... 4 3. Enable JavaScript in your

More information

TxEIS System Requirements

TxEIS System Requirements The System Requirements document includes settings that are recommended in order to utilize the TxEIS system at its fullest potential on any personal computer, including screen resolution and Internet

More information

Client Installation Guide

Client Installation Guide GENView Provisioning and Portals Portal Server Client Installation Guide Release: 9.4 Document revision: 03.01 Describes the steps for installing the GVPP-PS client application. www.genband.com 630-01903-01

More information

TxEIS on Internet Explorer 8

TxEIS on Internet Explorer 8 TxEIS on Internet Explorer 8 General Set Up Recommendations: Several modifications will need to be made to the computer settings in Internet Explorer to ensure TxEIS runs smoothly, reports pop up as desired,

More information

Internet Explorer 11 Settings

Internet Explorer 11 Settings Internet Explorer 11 Settings *Settings (steps 1-11) reference Windows 7. For Windows 8.1/10 settings, refer to page 7 Step 1: Click on Tools. (1a) Hover over SmartScreen Filter. (1b) Select Turn off SmartScreen

More information

Report Exec Enterprise Browser Settings. Choose Settings Topic

Report Exec Enterprise Browser Settings. Choose Settings Topic Report Exec Enterprise Browser Settings Choose Settings Topic Overview... 2 Technical Support... 2 Windows OS... 2 Microsoft Internet Explorer... 2... 2 Trusted Sites... 3 Browsing History... 3 Temporary

More information

Infinite Campus portal setup and trouble shooting guide for parents using IE7 Step 1

Infinite Campus portal setup and trouble shooting guide for parents using IE7 Step 1 Infinite Campus portal setup and trouble shooting guide for parents using IE7 Step 1 Your school office staff will provide you with a Personnel Summary Report that shows your Person GUID. Important: Verify

More information

Adobe Reader (AR) and Internet Explorer (IE) Browser Settings. Adobe Reader and Internet Explorer Browser settings

Adobe Reader (AR) and Internet Explorer (IE) Browser Settings. Adobe Reader and Internet Explorer Browser settings Adobe Reader and Internet Explorer Browser settings Table of Contents 1. INTERNET EXPLORER (IE) BROWSER SETTINGS... 2 1.1 Locating the menu bar... 2 1.2 Clearing cache... 2 1.3 Allow pop-ups from *.cap.org...

More information

University of Massachusetts

University of Massachusetts You should verify the following minimum desktop requirements before logging on to the HR Direct Application. It is recommended that you have the minimum requirements listed below to ensure the HR application

More information

Revised: March 8 th, 2017 for Firefox 52.0

Revised: March 8 th, 2017 for Firefox 52.0 Configuring Mozilla Firefox for Spectrum v14 Spectrum v14 runs in a browser window. As a result, there are a number of browser settings that impact how Spectrum will function. This document covers the

More information

KNOXPLANS for New Users

KNOXPLANS for New Users KNOXPLANS for New Users Version 9.1, October 2018 Contents KNOXPLANS for New Users... 1 Welcome to KnoxPlans, Version 9.1... 2 Recommended Client Hardware and O/S Specifications... 2 Browser Requirements...

More information

Learning Center Computer and Security Settings

Learning Center Computer and Security Settings Learning Center Computer and Security Settings Learning Center Computer Settings Please Note: To allow your computer to communicate most effectively with the Learning Center, and update your training record

More information

STEP 1 STEP 2 STEP 3 STEP 4 You may see the following. Then click OK. information on your screen: Click on the more apps to expand the list.

STEP 1 STEP 2 STEP 3 STEP 4 You may see the following. Then click OK. information on your screen: Click on the more apps to expand the list. Using Adobe Flash Software The S.T.A.B.L.E. Program Learner Course PowerPoint slides are packaged with Adobe Flash and will play using a Flash Player. This means you do not have to have PowerPoint installed

More information

ATS Questionnaire Management Interface (QMI) School Administrator Manual

ATS Questionnaire Management Interface (QMI) School Administrator Manual 2014 ATS Questionnaire Management Interface (QMI) School Administrator Manual 1 Table of Contents QMI: BATCH PAGE...3 LOGGING IN TO THE QUESTIONNAIRE MANAGEMENT INTERFACE...4 SEARCHING FOR EXISTING BATCHES...5

More information

Browser Client 4.0 Admin Guide

Browser Client 4.0 Admin Guide Browser Client is a web-based application that allows users to point their browser at a URL and view live video from a set of Intellex units. Browser Client 4.0 is compatible with Intellex 3.2 and 4.0

More information

Harmony. Computer Configuration Requirements. Version 2.1 December 2017

Harmony. Computer Configuration Requirements. Version 2.1 December 2017 Harmony Computer Configuration Requirements Version 2.1 December 2017 11711 W. 79th Street, Lenexa, KS 66214 Phone: (913) 307-1000 Toll Free: (888) 633-4927 www.mediware.com Workstation Configuration Requirements

More information

Configure Internet Explorer. Version 9 Settings for. CGM webpractice

Configure Internet Explorer. Version 9 Settings for. CGM webpractice Configure Internet Explorer Version 9 Settings for CGM webpractice 2 CompuGroup Medical Configure IE v9 Settings for CGM webpractice Revised: 3.23.2015 Table of Contents About this Document... 3 Configuring

More information

Full HD WDR Mini Dome IP Camera

Full HD WDR Mini Dome IP Camera Full HD WDR Mini Dome IP Camera User s Manual DN-16086 Ver. 1.0 Table of Contents 1. Overview... 2 1.1 Features... 2 1.2 Package Contents... 3 1.3 Dimensions... 4 1.4 Installation... 5 1.5 Connectors...

More information

If you would like to allow others to view your 1098T, you will need to provide them access through the Authorized Users menu.

If you would like to allow others to view your 1098T, you will need to provide them access through the Authorized Users menu. Current and former students, who are eligible to receive a 2016 1098T form, may view their form online through WebAdvisor. By clicking on Student Statement & Payment link under the Student Accounts heading,

More information

Make Your Computer Get Along With the MLS - 7 Easy Steps - (with pictures!)

Make Your Computer Get Along With the MLS - 7 Easy Steps - (with pictures!) Make Your Computer Get Along With the MLS - 7 Easy Steps - (with pictures!) You click a Search button in the MLS and you get a message that the page cannot be displayed. Or you click the Reports button

More information

FS-IP3000-M User Manual. Ver 1.0

FS-IP3000-M User Manual. Ver 1.0 FS-IP3000-M User Manual Ver 1.0 Sentry360 2014 Table of Contents 1. Overview... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Dimensions... 5 1.4 Installation... 6 1.5 Connectors... 7 2. Connect Ethernet

More information

Configure Internet Explorer. Version 9 Settings for. CGM webpractice

Configure Internet Explorer. Version 9 Settings for. CGM webpractice Configure Internet Explorer Version 9 Settings for CGM webpractice 2 CompuGroup Medical Configure IE v9 Settings for CGM webpractice Revised: 1.24.2014 Table of Contents About this Document... 3 Configuring

More information

Configure Internet Explorer Version 9 Settings for CGM webpractice

Configure Internet Explorer Version 9 Settings for CGM webpractice Configure Internet Explorer Version 9 Settings for CGM webpractice 2 CompuGroup Medical US Table of Contents About this Document... 3 Configuring IE Automatically Using CGM webpractice... 3 Configuring

More information

IHS Enerdeq Browser Release Notes Version 2.4.3

IHS Enerdeq Browser Release Notes Version 2.4.3 IHS > Decision Support Tool IHS Enerdeq Browser Release Notes Version 2.4.3 August 14 th, 2014 2014 IHS. All Rights Reserved. All trademarks belong to IHS or it s affiliated and subsidiary companies, all

More information

User Computer Requirements and Installation Guide

User Computer Requirements and Installation Guide User Computer Requirements and Installation Guide Updated: August 2014 1 CONTENT Introduction... 3 Client Configuration... 3 Supported Software... 4 Internet Explorer Settings... 5 Microsoft Office...

More information

IS-BL800 User's Manual

IS-BL800 User's Manual IS-BL800 User's Manual Ver 1.0 Sentry360 2015 Table of Contents 1. Overview... 3 1.1 Features... 3 1.2 Package Contents... 4 1.3 Dimensions... 5 1.4 Connectors... 6 1.5 microsd Card Slot / Default Button...

More information