WEA-Base Quick Guide
|
|
- Ross Osborne
- 5 years ago
- Views:
Transcription
1 WEA-Base Quick Guide Parameter set-up This quick guide deals only with the setting up of parameters of the WEA-Base weight transmitter. For more information refer to the weight transmitter user manual. Operation To navigate the parameters menu (see "Parameter menu: Calibration"), use push button S1 and joystick SW1. Push button S1: Back [Escape] Joystick SW1: SW1 is shown with the following symbols: [Up] [Down] [Right] [Left] [Enter] 1 2 To access the parameters menu, press [Enter]. To exit the menu, press [Escape], until the display flashes "SAVE". To save changes, press [Enter]. To exit without saving changes, press [Escape] twice. "SAVE" will not be displayed if the parameters are unchanged. NB.: Analogue and digital ouputs are inactive when parameters are being set up Calibration Theoretical calibration Enter load cell data from the data sheet. Calibration is calculated in the load cell amplifier, based on the data entered. Deadweight calibration The scale is loaded with a known weight. It is recommended, that the known weight is at least 70 % of the scale capacity. Once the deadweight calibration is complete, the theoretical values are updated in the load cell amplifier. The theoretical values can be used to transfer the calibration from one load cell amplifier to another. 1
2 Calibration parameters Total number of channels One channel twice for menu 1.1 Move SW1 to Select the desired number of channels. Example: Four channels 1,2,3 or 4 Load cell capacity 100 kg twice. Move SW1 to [Down], for menu 1.2. Example: 1000 kg Resolution 0.1 kg twice Example: , 0.002, 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 and 50 2
3 The scale's capacity kg 1.4. Filter Example: 5 1 = Min. filtering 10 = Max. filtering 3
4 Deadweight calibration Deadweight calibration can be done as a zero point calibration or/and as a point calibration. Zero point calibration 1.6. The display flashes, while the calibration is being executed. when the scale is empty. Continue to "1.6.2 Point calibration", or save the setting. Press S1 [Escape] to "SAVE". Point calibration Calibration with a known weight "Point calibration" 4
5 Place a known weight on the scale. NB: It is recommended, that the known weight is at least 70 % of the scale's capacity. Press S1 [Escape] to "SAVE". Example: 8110 kg Theoretical calibration Only active load cell channels can be selected. The values in "Theoretical calibration" are updated automatically after a "Deadweight calibration" and can be used as a backup or to transfer a calibration from one transmitter to another. Channel (theoretical zero point) 0mV/V 1.7. "Theoretical zero point". 1,2,3 or 4. Set the desired channel by moving SW1 to 5
6 Enter zero point mv/v. The zero-point is calculated on the basis of the load cell's capacity, described in the data sheet. Channel (Theoretical amplification) 2 mv/v Set the desired channel by moving SW1 to Enter load-cell amplification from data sheet. 6
7 Parameter menu: Calibration 1.1 Channels 1.2 Load cell Capacity 1.3 Resolution 1. Calibration 1.4 Weight Capacity 1.5 Filter 1.6 Dead. calibration Point Point Theo. calibration Zero Gain 7
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.4 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
More informationAnalogue Signal Transmitter AST 3 From prog.name A001A140. Operating instructions, Quick installation
GB Analogue Signal Transmitter AST 3 From prog.name A001A140 Operating instructions, Quick installation Operating instructions, Quick operation Contents Introduction... 1 Operating instruction General...
More informationCALIBRATION HI 2151/30 TRADITIONAL HARD CALIBRATION. Mode kg. Cal
CALIBRATION HI 2151/30 TRADITIONAL HARD CALIBRATION Motion Net ZERO Trk CTR Zero Gross lb Mode kg Tare Print ZERO Test/Clr 0.00 Enter Exit Cal The configuration menu information is entered two ways. o
More informationBHM Digital Indicator User s Manual
User s Manual Load Cell Central follows a policy of continuous improvement and reserves the right to change specifications without notice. 2015 Load Cell Central 28175 Route 220 Milan, PA 18831 Web: Email:
More information"Executive" PCU for Scanreco G4 systems SERVICE MANUAL
"Executive" PCU for Scanreco G4 systems SERVICE MANUAL SUMMARY 1. Characteristics... 2 1.1. Switching on the transmitter...2 2. Description of operation modes... 3 2.1. Operation mode (1)...3 2.2. Operation
More informationenod products range Digital process controllers
Titre enod products range Digital process controllers 1 Presentation What is enod? Products from enod range are measurement transmitters and powerful weighing process controllers enod transforms any strain
More informationSY061 Portable Load Meter with IEEE TEDS capability User Instructions
SY061 Portable Load Meter with IEEE1451.4 TEDS capability User Instructions Preliminary, relates to firmware version 1.2i Introduction The SY061 is a portable load meter, which can indicate the load present
More informationScout Pro FAQ. How to Turn On Units of Measure
Topic: This list compiles frequently asked questions about the Scout Pro: a) How do I turn on the units of measure b) How do I switch between units of measure c) How do I calibrate my unit How to Turn
More information6. VELOCITY/TEMPERATURE CALIBRATION
6. VELOCITY/TEMPERATURE CALIBRATION The EE75 can be calibrated / adjusted using either the buttons on the optional display module or the USB interface and configuration software provided. 6.1 Selecting
More informationPS-IN202 Weighing Indicator User Manual
PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO
More informationMODEL DAS 72.1 MANUAL
MODEL DAS 72.1 MANUAL DIGIAL LOAD CELL AMPLIFIER WIH ANALOGUE OUPU AND SEPOINS Digital Amplifier + Setpoint DAS 72.1 Made in EU by H&B Denmark Rel. 2 Rel. 1 Net SE UP 1.Zero 1.0/allow>0< 2.Calibrate 3.Set
More informationAdjustment instructions Pallet truck scales
KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen email: info@kern-sohn.com Phone: +49-[0]7433-9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com Adjustment instructions Pallet truck scales KERN VHT
More informationProgrammer User Manual CF800PROG
Programmer User Manual CF800PROG Cooper Safety Ltd Wheatley Hall Road Doncaster South Yorkshire DN2 4NB Tel: 01302 303 999 Fax:01302 303 333 South Yorkshire Web: www.cooperfire.com 1. General Description
More informationQuick Start Guide. System Release 1.0. Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link
Quick Start Guide System Release 1.0 Upgrade Notice Install Connectorized Radio Install Integrated Radio Power On Configure Units for Radio Link SPECIAL SOFTWARE UPGRADE NOTICE Important! All users of
More informationDCS Series. Digital Counting Scale. Setup Manual
DCS Series Digital Counting Scale Setup Manual Revision 1.1 February 12, 1997 1996-1997 Transcell Technology, Inc. Contents subject to change without notice. Transcell Technology, Inc. 975 Deerfield Parkway
More informationTransmitter WST 3 From prog. name W001A100. Technical Manual
GB Transmitter WST 3 From prog. name W001A100 Technical Manual Transmitter WST 3 Contents 1. Introduction Functions... 1-2 Technical data... 1-4 2. Installation General... 2-1 Electrical installation...
More informationIndustrial Weighing Systems
Industrial Weighing Systems 9 Richmond St. Picton, ON Canada K0K 2T0 Ph: 613-786-0016 Cell: 613-921-0397 Fax: 613-476-5293 E-mail info@iwsystems.ca Website: www.iwsystems.ca Industrial Weighing Sytems
More informationCut-True 29A & 29H Guillotine Cutters
Cut-True 29A & 29H Guillotine Cutters 11/2016 PROGRAMMING MANUAL First Edition Table of Contents TOPIC PAGE Calibration 1 Manual Mode 1 Absolute Mode 1 Incremental Mode 2 Manual Back Gauge Movement 2
More information5D Windows Configurator. Instruction Manual
5D Windows Configurator Instruction Manual 5D Windows Configurator Introduction The Windows configurator for 5D is a utility package that is sent out with every unit. It can also be downloaded from the
More informationFTK5 PROXIMITY KEYPAD
FTK5 PROXIMITY KEYPAD Before using the unit, please read the instructions and retain for future reference 1 There are 600 user codes (fobs or cards) and 1 programming code: Careful administration records
More informationDICKEY-JOHN GAC 2500-UGMA PRODUCT CALIBRATION DOWNLOAD
DICKEY-JOHN GAC 2500-UGMA PRODUCT CALIBRATION DOWNLOAD Product calibration files are located at the DICKEY-john website for loading to the GAC 2500-UGMA Grain Moisture Analyzer. If a USB memory device
More informationModel No Universal Input Indicator Start-up Guide
Model No. 1480 Universal Input Indicator Start-up Guide Contents 1. Setting up a unit straight out of the box... 3 1.1. Entry into Configuration mode... 3 1.2. Scrolling through Parameters and s... 3 1.3.
More informationWIZZO GLADIATOR JOYSTICK CONFIGURATION UTILITY QUICKSTART GUIDE V
WIZZO GLADIATOR JOYSTICK CONFIGURATION UTILITY QUICKSTART GUIDE V 1.0 07.09.2016 2016 VKB. All Rights Reserved. Written by Victorus / Edited by Jason Williams Table of Contents Introduction... 3 Configuration
More informationRGB LED FIXTURES WITH BUILT-IN INTELLIGENCE
RGB LED FIXTURES WITH BUILT-IN INTELLIGENCE USER S MANUAL TARGETTI SANKEY S.p.A Via Pratese, 164 50145 Firenze - Italia Tel. +39 055 3791.1 Tel. +39 055 3791.266 www.targetti.com Ref. 2S10CSD0 Summary
More informationSTEP 1: PREPARE FOR DATA MIGRATION 1. Right-click the desktop and choose New > Folder. a. Type For Transferring and press Enter to name the folder.
PC Support and Repair Chapter 5 Data Migration Lab 5144 When a new computer is purchased or a new operating system is installed, it is often desirable to migrate a user s data to the new computer or OS.
More informationSAFETY INSTALLATION OPERATION MAINTENANCE
SAFETY INSTALLATION OPERATION MAINTENANCE M A N U A L MASTERWEIGH INFINITY No. 556240 9575 N. 109 th Ave. Omaha, Nebraska 68142 (402) 330 1500 www.intersystems.net Intersystems MasterWeigh Infinity Configuration
More informationRDP CUSTOMER DOCUMENT
RDP CUSTOMER DOCUMENT Technical Manual for the E725 Microprocessor based Transducer Indicator/Controller DC Input Version Doc. Ref CD1421J Issue J This manual applies to units of mod status 6 ONWARDS BS
More informationOEM Digital NDIR CO sensor
OEM Digital NDIR CO sensor with flow-through gas cell Model 2015SPI-CO-20 The VALTRONICS Model 2015SPI-CO-20 is an OEM NDIR CO sensor with digital signal processing and temperature compensation. The firmware
More informationDCA - 10 / DCA TTS Systems
DCA - 10 / DCA - 20 Two Channell Load Cell Amplifie er Refere ence Manua al TTS Systems 14 Highpoint Business Village, Henwood,, Ashford, Kent,, TN24 8DH Telephone +44 (0)1233 624422 Telefax 0870 705 9678
More informationenod4 Weighing controller for automated systems
Titre enod4 Weighing controller for automated systems 1 Presentation What is enod4? enod4 is a weighing module especially designed for integration into an automated system It transforms any strain gauge
More informationINSTALLATION AND USER GUIDE
INSTALLATION AND USER GUIDE idialog - Translated from FRA original version (351910C-FR) - DOC REF : 351910C - EN TABLE OF CONTENTS 1 GENERAL SAFETY RULES... 3 2 OVERVIEW... 3 3 CONTENT OF USB CARD... 3
More informationModel ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide
Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR Thank you Thank you for purchasing a Mesa Labs Model ST-FT1 digital force / torque indicator, designed for use with a remote torque sensor. With proper usage,
More informationPA5000 SERIES USER MANUAL
PA5000 SERIES 4G CELL PHONE ENTRY SYSTEM USER MANUAL Rev. C Platinum Access Systems Inc. PRODUCT LINE PA5020 --- Cell Phone Entry System PA5022 --- Cell Phone Entry System (Flush Mount) SPECIFICATIONS
More informationACTION ELECTRONICS. P110 Operating Instructions
ACTION ELECTRONICS P110 Operating Instructions 1. Quick Start Guide Your P110 comes fully programmed & ready to go, there is no setup required although for more detailed setup refer to section 2. Installation
More informationStock Weigh 300. Operators Manual HELLO. Ft. Atkinson, Wisconsin USA. Panningen, The Netherlands
Stock Weigh 300 Operators Manual HELLO Ft. Atkinson, Wisconsin USA Panningen, The Netherlands www.digi-star.com D3734-US REV E October 31 st, 2012 SW300 User s Manual D3734-US REV E TABLE OF CONTENTS Table
More informationSLIM LINE Timer PREMIUM CONTROLS POWERED BY SW SUN CONTROL 5 YEAR MOTOR WARRANTY SLIM LINE TIMER TECHNICAL DATA SELECTING TIME & DATE.
SLIM LINE Timer 90 Channel TECHNICAL DATA Dimensions (inches).8 x 4.92 x.0 Weight (lbs).2 Power Supply V Lithium Battery Battery Life 2 Year Frequency 44. MHz Remote Range (feet) 6 SELECTING TIME & DATE
More information350 SMART MANOMETER OPERATING INSTRUCTIONS
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 350 SMART MANOMETER OPERATING INSTRUCTIONS Meriam Instrument s 350 Smart Manometer
More informationNorthQ Power Reader (NQ-9021) Technical Integration. Z-Wave Commands
NorthQ Power Reader (NQ-9021) Technical Integration Z-Wave Commands Table of Contents Power Reader NQ-9021 Power Reader...1 Overall device information...2 General description...2 Command classes supported...2
More informationAnalog Amplifier FAA-27. Technical Manual. Flintec GmbH Bemannsbruch Meckesheim GERMANY.
Analog Amplifier FAA-27 Technical Manual Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www.flintec.com Table of Contents 1. Safety Instructions... 2 2. Declaration Of Conformity... 3 3. Front View,
More informationIPM650 Intelligent Panel-Mount Display
Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationInstallation and Operation Manual HouseLINK HL-10P & HL-10P(LV)
Installation and Operation Manual HouseLINK HL-10P & HL-10P(LV) HouseLink HL-10P/HL-10P(LV) 9/4/2018 Table of Contents Table of Contents... 2 DESCRIPTION... 3 INSTALLATION... 3 ZERO Calibration Feature...
More informationDMC-688. When Accuracy Counts
DMC-688 Money Counti ng Scal e When Accuracy Counts Operation Manual 73360 DMC- 688 SERIES OPERATING MANUAL SECTION INDEX PAGE NUMBER 1.0. GENERAL 1.1. Unlocking Procedure 1.2. Setting Up 2 3 2.0. SPECIFICATIONS
More informationBlueDAQ QUICK START GUIDE Software for use with models BSC4D, BSC8D, BX8 and 9330
BlueDAQ QUICK START GUIDE Software for use with models BSC4D, BSC8D, BX8 and 9330 BlueDAQ Software Issue: 15-258 Revision A Quick Start Guide www.interfaceforce.com Interface Force Measurements Ltd, Unit
More informationTrend-1 Vibration Data Logger. User Manual
Trend-1 Vibration Data Logger User Manual Copyright College of Engineering-University of Basrah 2013 1 1. General Specifications 1.1 Features Thank you for being interested in purchasing Trend-1 Vibration
More informationIndustrial Weighing Systems
Industrial Weighing Systems 9 Richmond St. Picton, ON Canada K0K 2T0 Ph: 613-786-0016 Cell: 613-921-0397 Fax: 613-476-5293 E-mail info@iwsystems.ca Website: www.iwsystems.ca Industrial Weighing Sytems
More informationOperation Manual. Breeder Control Operation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending
Breeder Control Operation Manual Patented U.S. Patent No. 7,980,129 and Patents Pending 12/1/2012 Table of Contents Overview... 3 Components... 3 Bintrac Breeder Control... 3 Load Cell Bracket... 3 Smart
More informationMultiHandy Operating Instructions. Version 1.0 EN Firmware-Version 1.0 TKZ L EN
EN MultiHandy 2025 Operating Instructions Version 1.0 EN Firmware-Version 1.0 TKZ L3160-00-78.10EN OPERATING INSTRUCTIONS 1 Basics.............................. 1 1.1 Proper use...........................
More informationEconomy Charging Scale
Economy Charging Scale Capacity 100 kilograms (220 Pounds) Accuracy 0.5% of Reading +/- 1 Least Significant Digit Resolution 2g, 0.005 lbs., 0.1 oz. Power 4 x 1.5V AAA Alkaline Batteries (6 VDC) Battery
More information5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.
5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)
More informationOpenBSI Version 5.8 Product Enhancements
OpenBSI Version 5.8 has expanded upon and enhanced the following components, capabilities, and features: OpenBSI Version 5.8 ControlWave Designer Flash Configuration Online Editing Data Array Utility TechView
More informationGas Pedal Tester. APPLICATION GUIDE: Gas Pedal Tester OVERVIEW APPLICATION GUIDE T116. Installing the template. Requirements FUNCTIONAL TESTING
APPLICATION GUIDE FUNCTIOL TESTING APPLICATION GUIDE: Gas Pedal Tester Gas Pedal Tester T6 OVERVIEW This sigpod Gas Pedal application was designed to verify the operation of automotive pedal assemblies.
More informationEsys Braille Series. Tutorial 5 Tools ESYS FEATURES INTRODUCTION
Esys Braille Series Tutorial 5 Tools ESYS FEATURES INTRODUCTION Pressing centrally on the Left Joystick (LJ) will display the application menu. Pressing centrally a second time will display the main menu
More informationTALS 2. Torque Activated Logging System. Operating Instructions
TALS 2 Torque Activated Logging System Operating Instructions Contents Page 1. The TALS-2 Primary system 3 Items comprising TALS Core System 2. System Setup 4 3. Connecting The Power 5 4. To learn a new
More informationTCE Label Assistant Software User Manual
TCE Label Assistant Software User Manual Index 1. Overview and Features 1 Page 2. Software Guide 2 3. Printer Calibration 4 4. Example Use 5 1. Overview and Features Add text and number sequences Paste
More informationDEKKER KNOWLEDGE DATABASE KNOWLEDGE IS POWER
DEKKER KNOWLEDGE DATABASE For Use with DEKKER Vacuum Systems Equipped with the DEKKER Controller Each Vmax system is tested and checked at the factory prior to shipment to ensure trouble-free operation.
More informationINSTALLATION AND USER GUIDE
INSTALLATION AND USER GUIDE idialog - Translated from FRA original version (351910B-FR) - DOC REF : 351910B - EN TABLE OF CONTENTS 1 GENERAL SAFETY RULES... 3 2 OVERVIEW... 3 3 CONTENT OF USB CARD... 3
More informationModel 500 Digital Weight Indicator
Rev. 1.10 Serial Number: Model 500 Digital Weight Indicator USER MANUAL 1992-2000, Reliable Scale Corporation Reliable Scale Corporation 520 Moraine Road NE Calgary, Alberta, Canada Tel:1-800-419-1189
More informationCharacteristics and functioning
Characteristics and functioning 1/27 enod4-c Characteristics and functioning NU-eNod4C-ETH-E-1014_216706-A 1 ENOD4 PRODUCT RANGE... 4 1.1 General presentation... 4 1.2 Versions and options... 4 1.2.1 Versions...
More informationPresented By. NicolScales.com Contact Us
Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of
More informationM2500 Engine Controller Configuration Manual
M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2
More informationICA S & H Strain Gauge or Load Cell Embedded Analogue Amplifier. User Benefits. Ideal Applications
ICA S & H Strain Gauge or Load Cell Embedded Analogue Amplifier User Benefits A range of high performance robust signal conditioners in a miniature OEM format and designed specifically for fitting inside
More informationMicrosoft Office PowerPoint 2007: Basic Course 01 - Getting Started
Microsoft Office PowerPoint 2007: Basic Course 01 - Getting Started Slide 1 Getting started Course ILT Course objectives Explore the PowerPoint environment Get help by using PowerPoint s Help options Slide
More informationCharacteristics and functioning
Characteristics and functioning 1/1 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 2/2 enod4-t Characteristics and functioning 216702-C_NU-eNod4T-ETH-E-0314 1 ENOD4 PRODUCT RANGE...
More informationmedemagroup Joystick DX2 User guide P Q ver October 2011
medemagroup P9-0290-Q ver. 1.0.2 - October 2011 GB User guide Joystick DX2 Quick guide P9-0290-Q 2 of 16 Version 1.0.2/2011 Contents Introduction...4 Joystick parts...5 Operating...5 Clock on/off...6 Set
More informationUSER MANUAL Z-SG / Z-SG-L
USER MANUAL Z-SG / Z-SG-L Strain gauge converter with ModbusRTU protocol MI002633 Page 1 Non è stata trovata alcuna voce d'indice. Seneca Z-PC Line modules: Z-SG / Z-SG-L The Z-SG / Z-SG-L modules allows
More informationTHETA DIGITAL. master quickstart guide
THETA DIGITAL master quickstart guide Page 2 Step by Step Guide to Naming Inputs The Casablanca III HD can show up to four letters for input names on the front panel VFD (Vacuum Fluorescent Display). 2.
More informationVMB4PD Push Button and Timer Module for Velbus System
VMB4PD Push Button and Timer Module for Velbus System VMB4PD 1 Push Button and Timer Module for Velbus System VMB4PD Introduction This unique panel will let you control all of the output modules on the
More informationioselect Z-NET Z-SG Bridge Input Isolating I/O Module
-wire Bridge Connection Excitation for to 30 Ω Load Cells 00 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS8 Modbus RTU Superior Flexible Power:
More informationKEYFOB PROGRAMMING FOR ANNO PANEL
KEYFOB PROGRAMMING FOR ANNO PANEL 3. Press the NO button on the keypad and the screen will display: 4. Press the NO button on the keypad and the screen will display: OMIT INPUTS? Add New User? 6. Press
More informationModel 5030/5035 System Control Module Data Pack
Model 5030/5035 System Control Module Data Pack E NSEMBLE D E S I G N S Revision 3.1 SW 1.5.0 This data pack provides detailed installation, configuration and operation information for the 5030/5035 System
More informationG4 Multi Channel Weighing Instrument
GB G4 Multi Channel Weighing Instrument Program versions 1.7.0.0 to 1.10.0.0 Operating instructions, Quick installation RM type G4 Multi Channel Weighing Instrument Contents Introduction General... 1
More informationUSER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX
USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX DOCUMENT NO: TDC 0550 MANUAL - 2 1.0) INTRODUCTION. PAGE 2 1.1) ABOUT THIS MANUAL. PAGE 2 1.2) INTRODUCTION. PAGE
More informationUser s Guide. Series 2 DIGITAL FORCE GAUGES
Series 2 DIGITAL FORCE GAUGES Thank you Thank you for purchasing a Mark-10 Series 2 digital force gauge, designed for tension and compression force testing applications from 2 to 500 lbf (10 to 2,500 N)
More informationOptima OP-900-LD Score Board Indicator (with Remote Control) User Manual
Score Board Indicator (with Remote Control) User Manual Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance
More informationAE-2. Telephone Entry Control Console. Facility Manager s Programming Guide
AE-2 Telephone Entry Control Console Facility Manager s Programming Guide (760) 438-7000 FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com
More information& StartTime V ELECTRONIC START SYSTEM
USER S MANUAL & StartTime V ELECTRONIC START SYSTEM 3481.560.02 l Version 1.0 l July 2015 Swiss Timing LTD Phone +41 32 488 36 11 P.O. Box 138, Rue de l Envers 1 info@swisstiming.com CH-2606 Corgémont
More informationNOTE: It is easier to program the keypad prior to attaching it to the vehicle.
INSTALLATION All 2005 to Present Model Year Ford/Mercury/Lincoln Vehicles (Except 2013 Fusion) - With Keyless Remote Entry System - Key Start Removal - RF Keypad 1. Please read ALL of these instructions
More informationUniPak UP448 Bridge Input Isolating Signal Conditioner
6-wire Bridge Connection Excitation for to 350 Ω Load Cells 500 Volt (3-way) Isolation Excellent Accuracy (0.0%) DIP Switch Configuration Digital Input Tare Calibration RS85 Modbus RTU Superior Flexible
More informationNavigating Viewpoint V6 Function Keys
Navigating Viewpoint V6 Function Keys Table of Contents About this Course 3 F1 Online Help 4 F2 Rename Folder & Edit Cell 4 F3 Field Properties 4 F4 Lookup 6 F5 Setup 8 F6 Calculator 9 F7 Calendar 10 F8
More informationDATA SHEET Selectable AC transducer, TAS-321 DG
DATA SHEET Selectable AC transducer, TAS-321 DG Bi-directional current measurement on AC networks Power measurement using 2 phases on 3-phase networks Class 0.5 (IEC688) measurement Easy configuration
More informationDATA SHEET Selectable AC transducer, TAS-331DG
DATA SHEET Selectable AC transducer, TAS-331DG Measures power or reactive power on 3-phase AC networks Class 0.5 (IEC-688) measurement Supply and measuring voltage up to 690 V Easy configuration via PC
More informationModel 3000 Fieldbus Transmitter
Model 3000 Fieldbus Transmitter (for load cell based weighing systems) Installation & Operating Manual (Software Code PDT409 / Release 0.0) Modbus RTU / Profibus DP / DeviceNet Versions P.O. Box 775 -
More informationMODEL DAS 72.1 MKIII MANUAL
MODEL DAS 7. MKIII MANUAL DIGIAL LOAD CELL AMPLIFIER WIH ANALOGUE OUPU AND SEPOINS his Manual refers to software version. Ideas in Measuring.. Ideen & Meßtechnik ECHNIQUES LIMIED www.soemer.de www.sensortechniques.com
More informationMAN-652-OM1. 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. Rev. Date DESCRIPTION Prepared Approved
MAN-652-OM1 3 Oct 07 Revision G.R. G.A. 2 Jun 06 Revision A.G. G.A. 1 Feb 06 Revision A.G. G.A. 0 Sept 2005 First Issue A.G. G.A. Rev. Date DESCRIPTION Prepared Approved Note: Biffi Italia has taken every
More informationOEM Digital NDIR CO 2
OEM Digital NDIR CO 2 sensor with flow-through gas cell Model 2015SPI-3 The VALTRONICS Model 2015SPI-3 is an OEM NDIR CO 2 sensor with digital signal processing and temperature compensation. The firmware
More informationLab - Configure Data Backup and Recovery in Windows 7 and Vista
Lab - Configure Data Backup and Recovery in Windows 7 and Vista Introduction In this lab, you will back up data. You will also perform a recovery of the data. Recommended Equipment A computer with Windows
More information353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS
353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS The Model 353 provides Altitude, Rate of Climb (R of C), and Leak testing at the stroke of a key. It is microprocessor based and its accuracy is ±
More informationHandheld force display AE 703
Handheld force display AE 703 Original of Manual Marschnerstraße 26 01307 Dresden, Germany Phone +49 3 51 44 55 30 Fax +49 3 51 44 55 555 www.ast.de vertrieb.dd@ast.de 1 Contents 1. Scope of use... 1
More informationBATTERY MAINTENACE ERROR MESSAGE SPECIFICATIONS... 22
2 CONTENTS PRECAUTIONS... 4 PREFACE... 6 NAMES AND FUNCTIONS... 6 OPERATIONS... 9 1. Simple Weighing Mode... 9 2. Weighing with Tare... 9 3. Changing Unit of Weight... 10 4. Hold Function (SW-1S, SW-1W
More informationproduct manual HS-4157 Point Load Tester
06.18 product manual HS-4157 Point Load Tester INTRODUCTION The HS-4157 Point Load Tester is a high-resolution digital pressure gauge that measures with high accuracy. Easy to install and critical pressure
More informationPROXIMITY SENSORS SEZ/SEM SERIES
PROXIMITY SNSORS SZ/SM SRIS Description SM/SZ series touchless sensors are designed to detect objects through most materials. They operate from low voltage power source and provide simple digital or analog
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationInformation Sheet IS13004A
Information Sheet IS13004A NV and NX Series - Burning Compact Flash Card Issue 1.3... 20 November 2015 Nautel Limited 10089 Peggy's Cove Road, Hackett's Cove, NS, Canada B3Z 3J4 T.877 6 nautel (628835)
More information39E Electronic Combination Lock SETUP INSTRUCTIONS
The ComboGard Pro Lock has three states of operation: Factory Default, Manual Setup, and Active. ComboGard Pro locks are shipped from LA GARD in Factory Default state without Users or features enabled.
More informationRTC 300/RTC 600 Installation instructions scan
RTC 300/RTC 600 Installation instructions DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4189350071A SW version: 1. 1.1. Introduction...3
More informationAL101A1A Joystick Controller for Operating a Snow Plow
AL101A1A Joystick Controller for Operating a Snow Plow page Modes of operation, Deadman, Float 2 Program mode, unlock 3 Program address list, settings, ranges, presets 4 Wiring connections, joystick 5
More informationCOMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.
COMPLETE MANUAL WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. TI-1200-S without rechargeable battery and with a smaller cabinet. Note: When TI-1200 is shipped as a part of
More informationPmodJSTK2 Reference Manual. Overview. 1 Functional Descriptions. Revised July 19, 2016 This manual applies to the PmodJSTK2 rev. C
1300 Henley Court Pullman, WA 99163 509.334.6306 www.digilentinc.com PmodJSTK2 Reference Manual Revised July 19, 2016 This manual applies to the PmodJSTK2 rev. C Overview The Digilent PmodJSTK2 (Revision
More informationPKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06
PKP Prozessmesstechnik GmbH Borsigstrasse 24 D-65205 Wiesbaden-Nordenstadt Tel: 06122 / 7055-0 Fax: 06122 / 7055 50 Operating manual PSA06 Electronical pressure switch Content Page 19-34 1. Foreword 19
More information