1 I n s t a l l a t i o n M a n u a l f o r T E D P r o ( T P C O n l y ) A B C

2 Page 2 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * I M P O R T A N T The successful installation of your TED Pro system requires that a very specific installation-sequence be followed. It is CRITICAL that these steps are completed in the following order: A. The 1st step in the sequence is the installation/setup of the MTU Pro (this document). B. The 2nd step - (only after the MTU Pro is installed/set up), the installation/setup of the Spyder(s). Link to the Spyder Installation Guide: C. The 3rd step - (only after the 1st and 2nd steps have been completed) - TED Commander activation/setup. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. TED Pro Quick Start Guide IMPORTANT: This Quick Start Guide is a summary of the main aspects of MTU installation, and is specific to Schlumberger installations. The complete Installation Instructions, can be found on the TED website at: Copyright Energy, Inc. All rights reserved

3 Page 3 CTs (Current Transformers): CTs clip around the conductor for each phase, with RED polarity dot facing source of power, i.e. the utility. Connectors: Insert the CT connectors with the tab facing UP to lock under the ridge of the MTU connector. STEP 1 MTU Power Cable Connection Select a 3-pole breaker (40A max) for power cable connection and turn breaker OFF. (Connection to a circuit breaker greater than 40A will require a 15A or 20A inline fuse). Connect MTU Power Cable wires as follows: Black to Phase A, Red to Phase B, Blue to Phase C, White to Neutral. Connect MTU power cable to MTU. Power ON breaker. Default Phase Configuration is 3-Phase, 4-wire Wye. NOTE: MTU must be installed on the outside of the panel. Red Polarity Dots facing Utility Main Circuit Breaker MAX 1200A CT s Incoming Power Lines MAX 600V MAX 1200A Phase A Phase C Ethernet cable to Router Phase B Neutral Ethernet Cable Ethernet Port Power Connector MTU (Measuring/Transmitting Unit) C B A CT Connectors Approved Cable Connector or Bushing A B C A B C A B A B C A B C A B Neutral Bus White (neutral) Blue (phase C) Black (phase A) Red (phase B) Figure 3(b) Installation of MTU (communication via Ethernet) 15, 20, or 30A Circuit Breaker

4 Page 4 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * STEP 2 Accessing the MTU UI page Connect Ethernet cable from MTU to router or network drop. Download and RUN the TED Installation Utility (shown below) from the following link: This utility will detect TED devices on your Network. Select MTU3000 when it appears in the window and click LAUNCH IN BROWSER. Copyright Energy, Inc. All rights reserved

5 Page 5 STEP 3 Once on the MTU UI page, select Stats to view the statistics page (cut-out shown below). To ensure the connections are correct, turn on some substantial loads and observe that the Active Power for each phase is positive. Also, the PF (Power Factor) would typically be >800 (80.0%) (in the example on the next page, the PF is 92.0%). If ANY of the phases do not show a positive Active Power and >80.0% PF, then there is a mismatch between the CT and Voltage Connections. Then, while the MTU is under power, remove all CT inputs and place the A wire into the A, B, and C ports to see where the Active Power is positive and has the highest PF. Repeat for B and C. Verify all 3 phases STEP 4 Accessing TED FOOTPRINTS Plug Ethernet cable from ECC to router or network drop. RUN the TED Installation Utility: This utility will detect TED devices on your Network. Select TED6000 (this is the ECC identifier) when it appears in the window and click LAUNCH IN BROWSER.

6 Page 6 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * STEP 5 This will launch TED Footprints. Once in TED Footprints, select SETTINGS tab and then System Settings... then select System Layout. (The User Manual is also available under the HELP tab in TED Footprints) Leave all MTUs set to NET Copyright Energy, Inc. All rights reserved

7 Page 7 STEP 6 Follow the instructions in the ECC User s Manual for entering settings in System Settings Wizard. Once on the Product Identification tab, CAREFULLY ENTER MTU IDs. For single MTU systems, enter MTU ID here (if you have multiple MTUs, see below) Example System Layout With Multiple MTUs For installations with multiple MTUs and ECCs, give each MTU and the ECC an abbreviated name in the Description field.

8 Page 8 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * STEP 7 Once you have entered all the information, select the Write to ECC tab and select UPDATE. This will save all your entries to the TED system. You may make changes in System Settings at any time (changes are not retroactive and do not change historical data). Copyright Energy, Inc. All rights reserved

9 Page 9 Appendix A-1 NOTES: PLC TRANSMISSION ECC TO THE ECC IS ON PHASE A. CONNECT ECC TO PHASE ECC A CIRCUIT OR MOVE BLACK WIRE TO ECC PHASE THEN CONTINUE DOWN RED, BLUE. PLC TRANSMISSION WILL BE SEVERELY DEGRADED IF BLACK WIRE ON MTU ECC AND ECC ARE NOT ON THE SAME PHASE. SOME COUNTRIES MAY REQUIRE THAT DIFFERENT WIRE COL- ORS BE USED. USE PHASE-IDENTIFICATION TAPE OR OTHER MEANS AS REQUIRED BY YOUR LOCAL AUTHORITY. SET MTU INSTALLATION TYPE IN ECC MTU UI PAGE

10 Page 10 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Appendix A-2 Tie White Wire to Neutral Bus NOTES: PLC TRANSMISSION CANNOT BE USED ON DELTA CIR- CUIT BECAUSE THERE IS NO NEUTRAL.. CONNECT TO ECC VIA ETHERNET. SOME COUNTRIES MAY REQUIRE THAT DIFFERENT WIRE COLORS BE USED. USE PHASE IDENTIFICATION TAPE OR OTHER MEANS AS REQUIRED BY YOUR LOCAL AUTHORITY. INSTALLATION TYPE MUST BE SET AS 3W DELTA IN MTU ECC UI PAGE FOR PROPER OPERATION. Copyright Energy, Inc. All rights reserved

11 Page 11 Appendix A-3 NOTES: FOR CORRECT OPERATION, BLUE WIRE MUST BE CONNECTED TO THE HIGH LEG. PLC TRANSMISSION TO THE TO THE ECC ECC IS ON IS PHASE ON PHASE A. CONNECT A. ECC TO PHASE A CIRCUIT. ECC PLC TRANSMISSION WILL BE SEVERELY DEGRADED IF BLACK WIRE ON MTU AND ECC ARE NOT ON THE SAME PHASE. ECC SOME COUNTRIES MAY REQUIRE THAT DIFFERENT WIRE COL- ORS BE USED. USE PHASE-IDENTIFICATION TAPE OR OTHER MEANS AS REQUIRED BY YOUR LOCAL AUTHORITY. SET MTU INSTALLATION TYPE IN ECC MTU UI PAGE

12 Page 12 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Appendix A-4 NOTES: PLC TRANSMISSION TO THE ECC IS ON PHASE A. CONNECT ECC TO PHASE A CIRCUIT ECC OR MOVE BLACK WIRE TO ECC PHASE. PLC TRANSMISSION ECC WILL BE SEVERELY DEGRADED IF BLACK WIRE ON MTU AND ECC ARE NOT ON THE SAME PHASE. ECC SOME COUNTRIES MAY REQUIRE THAT DIFFERENT WIRE COL- ORS BE USED. USE PHASE-IDENTIFICATION TAPE OR OTHER MEANS AS REQUIRED BY YOUR LOCAL AUTHORITY. SET MTU INSTALLATION TYPE IN MTU UI PAGE ECC Copyright Energy, Inc. All rights reserved

13 Page 13 Appendix A-5 PLC Signal NOTES: PLC TRANSMISSION TO THE ECC ECC IS ON PHASE A. CONNECT ECC TO PHASE A ECC CIRCUIT OR REVERSE THE RED AND BLACK WIRES. PLC TRANSMISSION WILL BE SEVERELY DEGRADED IF BLACK WIRE ON MTU AND ECC ARE NOT ON THE SAME PHASE. ECC SOME COUNTRIES MAY REQUIRE THAT DIFFERENT WIRE COL- ORS BE USED. USE PHASE-IDENTIFICATION TAPE OR OTHER MEANS AS REQUIRED BY YOUR LOCAL AUTHORITY. SET MTU INSTALLATION TYPE IN MTU UI PAGE ECC

14 Page 14 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Appendix A-6 APPENDIX A-6 WIRING DIAGRAM 1-PH-2-W SINGLE PHASE MTU3000 / MTU Pro Copyright Energy, Inc. All rights reserved

15 Page 15 Appendix B ROGOWSKI COIL OPTION: Rogowski coils are flexible CT ropes that allow for connecting around multiple conductors or even around bus bars. 1. The Rogowski MTU option available from TED has specially modified inputs to accommodate the output from the Rogowski Coils. Care should be taken that standard CTs are not connected to Rogowski MTUs, this could cause irreversible damage to the MTU. 2. The MTUs are calibrated to the coils with which they are shipped. Each coil is marked by phase and must be connected in the proper CT input. (A Black, B RED, C BLUE). 3. Position arrow so it correctly shows flow of current. 4. Verify that the Rogowski check-box on the MTU UI has been selected for proper readings. Coil Spec: 2000A coil is 24 inches. 5000A coil is 36 inches. Arrow indicating flow of current Panel Meter Current Flow

16 Page 16 Please see the following link for TED Terms and Glossary: N O T E S

17 Page Marina Drive Charleston, South Carolina (843) (800) * ** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * Copyright Energy, Inc. All rights reserved

I n s t a l l a t i o n M a n u a l. T E D P r o A B C. Rev 4.2

I n s t a l l a t i o n M a n u a l. T E D P r o A B C. Rev 4.2 I n s t a l l a t i o n M a n u a l f o r T E D P r o A B C Rev 4.2 Page 2 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * IMPORTANT: The installation of your TED Pro system

More information

I n s t a l l a t i o n M a n u a l. T E D P r o A B C. Rev 3.3

I n s t a l l a t i o n M a n u a l. T E D P r o A B C.   Rev 3.3 I n s t a l l a t i o n M a n u a l f o r T E D P r o A B C Rev 3.3 Page 2 * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * IMPORTANT: The installation of your TED Pro system

More information

Remote Access to Energy Data

Remote Access to Energy Data Remote Access to Energy Data Page 1 There are several ways in which you can access your TED-data remotely. TED Commander 3rd Party Posting Port Forward Internet Access Options Definitions: TED Commander

More information

TED Pro User Manual TABLE OF CONTENTS 1. Accessing Footprints Page 2 2. Live Dashboard Page 3 3. Setup Page System Settings Wizard

TED Pro User Manual TABLE OF CONTENTS 1. Accessing Footprints Page 2 2. Live Dashboard Page 3 3. Setup Page System Settings Wizard TED Pro User Manual TABLE OF CONTENTS 1. Accessing Footprints Page 2 2. Live Dashboard Page 3 3. Setup Page 3 3.1 System Settings Wizard Page 4 3.2 Spyder Setup and Operation Page 6 3.3 Spyder Calibration

More information

Page 1 TED Commander User Manual The following instructions are the recommended method for TED Pro customers using Footprints software to Activate the ECC to post to TED Commander. Before activating the

More information

Installation manual for for Schleifenbauer DPM3

Installation manual for for Schleifenbauer DPM3 Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation

More information

EnerSure Installation Guide

EnerSure Installation Guide EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded

More information

BLUE 3 INSTALLATION GUIDE

BLUE 3 INSTALLATION GUIDE BLUE 3 INSTALLATION GUIDE CATCH Power BLUE 3 Installation manual - Page 1 IMPORTANT This product must be installed by a licensed electrician. This product must be installed according to the AS3000 Australian

More information

RIK-5A Flexible Current Tranformer User's Manual

RIK-5A Flexible Current Tranformer User's Manual RIK-5A Flexible Current Tranformer User's Manual Copyright 2017 V1.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written consent of Accuenergy.

More information

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA User's Manual Copyright 2017 V1.00 This manual may not be altered or reproduced in whole or in part by any means without the expressed written

More information

Application Techniques CENTERLINE 2100 Motor Control Centers

Application Techniques CENTERLINE 2100 Motor Control Centers POWER SYSTEM CONSIDERATIONS FOR PRODUCT SELECTION Application Techniques CENTERLINE 2100 Motor Control Centers Power System Considerations for Product Selection i Power System Considerations for Product

More information

*****CAUTION/ATTENTION***** Before You Start...

*****CAUTION/ATTENTION***** Before You Start... Quickstart Guide 1. Introduction 2. Understanding Phases 4. Voltage Connection 5. Current Sensors 3. Network Connection 6. Commissioning 7. FAQs + Configuration *****CAUTION/ATTENTION***** Before You Start...

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

AcquiSuite Ally 48 Advanced Branch Circuit Monitor AcquiSuite Ally 48 Advanced Branch Circuit Monitor AMC48-MD AMC48-ED Split Core CT Split Core CT Ally Rogowski Rope CT DESCRIPTION The AcquiSuite Ally 48 is the perfect companion to the data acquisition

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

Energy Meter and. Current Transducer. Assembly Manual

Energy Meter and. Current Transducer. Assembly Manual Energy Meter and Current Transducer Assembly Manual 2017 1 The energy meter assembly is made of two separate boxes and associated accessories, as follows: Energy Meter (EM) Box, with two cables feeding

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

ST: TP14D/2 TEST SHEET COMBINED LV CT & METER CABINET INSTALLATIONS OFF-LOAD TESTING

ST: TP14D/2 TEST SHEET COMBINED LV CT & METER CABINET INSTALLATIONS OFF-LOAD TESTING COMBINED LV CT & METER CABINET INSTALLATIONS Summary This Test Sheet shall be employed during the off-load testing of Combined LV CT & Meter Cabinet Installations in accordance with Standard Technique

More information

4. Enter LOCATION CODE 4.1 From LOCATION CODE screen press CHANGE button. Arrow points to first digit

4. Enter LOCATION CODE 4.1 From LOCATION CODE screen press CHANGE button. Arrow points to first digit 5000 BIRD DOG PLUS STANDARD TEST PROCEDURE FOR SINGLE ELEMENT METER CIRCUIT TESTING ONLY (Save ONLY the GLOB SAVE Screen Forms 3, 4, 5, 6, 8, 9 Meter Circuits) 1. Hookup Probes to Phase A (or B or C as

More information

1-Line Load Calculation Software. User s Manual APPROVED. Copyright 2013 Durand & Associates. Page 1

1-Line Load Calculation Software. User s Manual APPROVED. Copyright 2013 Durand & Associates. Page 1 1-Line 2014 Load Calculation Software User s Manual APPROVED Copyright 2013 Durand & Associates Page 1 1-LINE 2014 COPYRIGHT 2013 - DURAND & ASSOCIATES This software and manual are protected by Federal

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

UNIT 2 Three-Phase Transformer

UNIT 2 Three-Phase Transformer UNIT 2 Three-Phase Transformer 2-1 Three-Phase Connections EXERCISE 2-1 OBJECTIVE After completing this exercise, you should be able to connect three-phase transformers in various configurations and measure

More information

Control Box Setup - PRSalpha

Control Box Setup - PRSalpha 888-680-4466 ShopBotTools.com Control Box Setup - PRSalpha Copyright 2016 ShopBot Tools, Inc. page 1 Copyright 2016 ShopBot Tools, Inc. page 2 Parts List: Hooking Up a PRSalpha Gantry Tool Powering the

More information

M215 Microinverter Installation Planning

M215 Microinverter Installation Planning TECHNICAL BRIEF M215 Microinverter Installation Planning The M215 Microinverter The M215 Microinverter is a powerful and efficient grid-tied microinverter. It is compatible with most 60- cell PV modules

More information

NEW ERA METER. Installation & Operation Guide NE METER

NEW ERA METER. Installation & Operation Guide NE METER NEW ERA METER Installation & Operation Guide NE METER Autoranging Power Supply Installation Diagnostics Per Phase Voltage & Current kwh, Demand and TOU 0.2% Accuracy -40 C to +85 C Watertight Enclosure

More information

Installation Instructions & User Manual

Installation Instructions & User Manual Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062

More information

ECS LUCY GEMINI 3 CONFIGURATION PROCEDURE

ECS LUCY GEMINI 3 CONFIGURATION PROCEDURE Document Number: ECS 05-9541 Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 05-9541 LUCY GEMINI 3 CONFIGURATION PROCEDURE EPN, LPN, SPN This document details the configuration procedure for

More information

IIM Warwick Court. Williamsburg VA REV 5

IIM Warwick Court. Williamsburg VA REV 5 1 1-757-258-3939 100 Warwick Court Williamsburg VA 23185 REV 5 2 Technical Specification >Accuracy Better than + 1% over a range of 1.5 to 200 amperes with power factor ranging from 1 to 0.5 Approved by

More information

LED. Sign Module. Assembly Manual

LED. Sign Module. Assembly Manual LED Sign Module Assembly Manual 6/14/2002 3:10 PM 6 2 3 3 E. S a w g ra s s R d S a ra s o ta, F L. 3 4 2 4 0 (9 4 1 )3 7 7-5 7 7 5 F A X(9 4 1 )3 7 8-4 2 2 6 www.acscontrol.com Table of Contents Table

More information

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Mini Clamps: Part Number 111.7015 PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Description 10 ma-to-20 A or 100 ma-to-200 A. Switchable range mini clamp. 40 Hz 20 khz 4 x mini

More information

Integrated Metering Systems, Inc.

Integrated Metering Systems, Inc. Integrated Metering Systems, Inc. Models beginning with S3 Single Meter in Enclosure Product Features Installationn Instructions User s Manual PN: 114-0005 Revision 0.12 Table of Contents List of Figures...

More information

Commission Testing Methods for Protection Systems

Commission Testing Methods for Protection Systems Commission Testing Methods for Protection Systems Tom Ernst GE Grid Solutions Ken Sletten Minnesota Power Abstract Commission testing should be designed to assure that the protection system is set and

More information

Page 1 TED Commander User Manual The following instructions are the recommended method for TED Pro customers using Footprints software to Activate the ECC to post to TED Commander. Before activating the

More information

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation. Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

How to Install a Verdigris System (V1.9)

How to Install a Verdigris System (V1.9) How to Install a Verdigris System (V1.9) Welcome! This manual will guide you on how to install your new system. If you need direct assistance, call our support line at 1-844-837-3447 or email support@verdigris.co.

More information

DPM Active Harmonic Filter Quick Start Instructions

DPM Active Harmonic Filter Quick Start Instructions DPM Active Harmonic Filter Quick Start Instructions These instructions will guide you through installing, testing your installation, and starting up your DPM. For additional information please refer to

More information

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB APPENDIXB This appendix lists the cable specifications for supported modules on the Cisco 7600 series router. The following signal summaries are contained in this appendix: Interface Specifications, page

More information

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS

mv/v Output MELT PRESSURE TRANSMITTERS I3 SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS I3 SERIES mv/v Output D The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions 299-600-96 Rev. F MCG Surge Protection Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions Important Warranty Information: MCG surge protectors are designed to work at specific voltages

More information

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers DECK All-In-One Enclosure Quick Installation Guide for Field Installers 1 Contents Legal Statement... 2 Preliminary Considerations... 2 Required Installation Tools and Materials... 2 Networking Information...

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices.

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

Power distribution systems - accessories

Power distribution systems - accessories Connections and terminals Line terminal X 221 3 01 Power-D-Box with sockets pre-wired Line terminal (max. 63 A) X 221 3 01 14.551 max. tightening torque 3.0 Nm 15.591 busbar X1, X2 blade terminals 6.3

More information

Saturn Mini CT (SS9000/SS9007) Product and Driver Installation Guide. Revision: 3.0 Date: Monday, July 10, 2017 Authors: Gareth Sanders, Alan Chow

Saturn Mini CT (SS9000/SS9007) Product and Driver Installation Guide. Revision: 3.0 Date: Monday, July 10, 2017 Authors: Gareth Sanders, Alan Chow Saturn Mini CT (SS9000/SS9007) Product and Driver Installation Guide Revision: 3.0 Date: Monday, July 10, 2017 Authors: Gareth Sanders, Alan Chow Contents Overview... 3 Section 1: Device Installation...

More information

SECTION ( ) LIGHTING CONTROL PANELBOARD

SECTION ( ) LIGHTING CONTROL PANELBOARD (26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting

More information

Troubleshooting guide for the S100 Energy meter and EPS

Troubleshooting guide for the S100 Energy meter and EPS Troubleshooting guide for the S100 Energy meter and EPS The S100 Energy Meter is the brains of the Sungrow hybrid system. It tells the inverter when to charge or discharge the battery, when to go into

More information

Written By: Charlie Mohr

Written By: Charlie Mohr NEC LCD1770NX Capacitor Replacement Replacement of a capacitor on the power supply circuit board. Written By: Charlie Mohr ifixit CC BY-NC-SA www.ifixit.com Page 1 of 14 INTRODUCTION There are many capacitors

More information

Stepper. Manuals about stepper drives. Stepper Drive Wiring Diagram - Apollo Stepper Drive Setup Guide

Stepper. Manuals about stepper drives. Stepper Drive Wiring Diagram - Apollo Stepper Drive Setup Guide Stepper Manuals about stepper drives Stepper Drive Wiring Diagram - Apollo Stepper Drive Setup Guide Stepper Drive Wiring Diagram - Apollo Cont rol Connect or Signal PUL+ PUL DIR+ DIR EN+ EN Color Brown/White

More information

SEM3 - Embedded Micro Metering Module

SEM3 - Embedded Micro Metering Module SEM - Embedded Micro Metering Module Quick Reference Guide and Installation Instructions Scan QR Code for more information usa.siemens.com/sem Installation! DANGER Hazardous Voltage. Will cause death or

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA

Model Number Electrical Compatibility Module Connector Type M LL-S22 M LL-S22-NA M LL-S23 M LL-S23-NA M215 Microinverter Installation Planning The Enphase M215 Microinverter The M215 Microinverter is Enphase s most powerful and efficient model yet. This grid-tied microinverter is compatible with most 60-cell

More information

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN. The 12.5kW power shelf accepts 3-phase input power and provides stable DC output power (1000A at 12.5VDC). The OCP 21-inch power shelf includes a total of 5+5 high-power, hot-swappable PSUs in redundant

More information

ABB Digital medium-voltage switchgear

ABB Digital medium-voltage switchgear NAMIBIA AMEU/AEDU MARCH 2018 ABB Digital medium-voltage switchgear Barry Addinall UniGear Digital Contents 1. Digital switchgear 2. Complexity of Distribution networks 3. New technologies using digital

More information

i-3 Control Technology

i-3 Control Technology i-3 Control Technology Submittal Guide www.usa.siemens.com/i-3 Contents P1 Series Lighting Panel 4-6 i-3 Controller 7 SIPOD specifications 7-8 Inputs and Communications 9 Protocol Connections System Connections

More information

ADDENDUM FOR 20, 27, & 28 OPTIONS

ADDENDUM FOR 20, 27, & 28 OPTIONS ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and

More information

BLU- CIF Interface Board

BLU- CIF Interface Board BLU- CIF Interface Board The BLU-CIF Interface Board simplifies the wiring of all of the BLU products to the BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination, as

More information

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010 NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 SUPPLEMENTARY EXAMINATION 2010 (12041032) 4 March (X-Paper) 09:00 12:00 This question paper consists of 6 pages. (12041032)

More information

This user manual is designed to help the operators and owners of Soft-LED products use, troubleshoot, and utilize all of the product s potential.

This user manual is designed to help the operators and owners of Soft-LED products use, troubleshoot, and utilize all of the product s potential. This user manual is designed to help the operators and owners of Soft-LED products use, troubleshoot, and utilize all of the product s potential. Customers seeking additional help not mentioned in this

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

ECM-1220 User s Manual

ECM-1220 User s Manual 1 ECM-1220 User s Manual Table of Contents ECM-1220 User s Manual...1 Table of Contents...1 Introduction / How It Works...2 Safety...4 Quick Start...5 Verifying / Changing Settings...6 Installation...8

More information

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc.

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. MOTOR SYMBOLS. 2010, The McGraw-Hill Companies, Inc. Chapter 2 MOTOR SYMBOLS 1 Symbols are used to represent the different components of a motor control system. Symbols sometimes look nothing like the real thing, so we have to learn what the symbols mean.

More information

Series 3000 User Manual and Product Features

Series 3000 User Manual and Product Features Series 3000 User Manual and Product Features PN: OXA3501-890000 Revision 1.0 Technical Specifications 1.1 Model Number Description 1. Meter Series S3 Series 3000 meter Figure 1: Series 3000 model number

More information

BLU- CIF2 Interface Board

BLU- CIF2 Interface Board BLU- CIF2 Interface Board The BLU-CIF2 Interface Board simplifies the wiring of all of the BLU products to two BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination,

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Integrated Metering Systems, Inc.

Integrated Metering Systems, Inc. Integrated Metering Systems, Inc. Models beginning with MS120F and MD240F Mini Meter in Flush Mount Enclosure Product Description Technical Specifications Installation Instructions PN: 114-0003 Revision

More information

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage

More information

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual Surge Protective Devices STV100K Series Instruction Manual Contents 1.0 Installation... 4 1.1 Environment... 4 1.2 Mounting... 4 1.3 Proper Connection of SPDs... 4 1.4 Mechanical Dimensions... 5 1.5 Voltage

More information

Installation & Quick Start Guide WL510 Wireless Adaptor/Antenna

Installation & Quick Start Guide WL510 Wireless Adaptor/Antenna Installation & Quick Start Guide WL510 Wireless Adaptor/Antenna IMPORTANT INFORMATION ABOUT YOUR WL510 IP Address = 192.168.10.20 Password = wl510 QUICK START WL510-01- VR2.00 1. Introduction Congratulations

More information

Common Departures Interconnecting Facilities Requirements

Common Departures Interconnecting Facilities Requirements Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Ordering Information CIBANO 500

Ordering Information CIBANO 500 Ordering Information CIBANO 500 CIBANO 500 Packages CIBANO 500 Package including cables and accessories Description Package for standard tests on MV and HV CBs. No additional measuring accessories. Rewiring

More information

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs) Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2

More information

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Voltage Output MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS MELT PRESSURE TRANSMITTERS IN SERIES Voltage Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium pressure

More information

4. Enter LOCATION CODE 4.1 From LOCATION CODE screen press CHANGE button. Arrow points to first digit

4. Enter LOCATION CODE 4.1 From LOCATION CODE screen press CHANGE button. Arrow points to first digit 6000 BIRD DOG PLUS STANDARD TEST PROCEDURE FOR SINGLE ELEMENT METER CIRCUIT TESTING ONLY (Save ONLY the GLOB SAVE Screen Forms 3, 4, 5, 6, 8, 9 Meter Circuits) 1. Hookup Probes to Phase A (or B or C as

More information

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS

Voltage Output IMPACT MELT PRESSURE TRANSMITTERS IN SERIES TECHNICAL SPECIFICATIONS IMPACT MELT PRESSURE TRANSMITTERS IN SERIES Voltage Output The IMPACT series of Gefran, are pressure transmitters, without transmission fluid, for using in High temperature environment (350 C). Medium

More information

Panoramic Power. Deployment Tool User Guide. v 4.99

Panoramic Power. Deployment Tool User Guide. v 4.99 Panoramic Power v 4.99 Copyright Notice Copyright 2015 Panoramic Power Ltd. All rights reserved. 2 Contents Overview... 4 Installing the Deployment Tool... 4 Launching the Deployment Tool... 4 Mapping

More information

Advisor Advanced Pedestrian System (AAPS) Installation Guide

Advisor Advanced Pedestrian System (AAPS) Installation Guide 1 Advisor Advanced Pedestrian System (AAPS) Installation Guide 906-0004 Revision B November 1, 2012 This Installation Guide provides guidance to those involved in the installation of the application. This

More information

Optimierung Schmiersysteme_V

Optimierung Schmiersysteme_V GÜDEL AG Industrie Nord CH-900 Langenthal Tel +1 (0) 91 91 91 Fax +1 (0) 91 91 0 Email info@ch.gudel.com Customer address Industrie Nord 900 Langenthal Schweiz Project Projectnumber Project description

More information

PDU Branch Current Monitoring Board Installation and Configuration

PDU Branch Current Monitoring Board Installation and Configuration PDU Branch Current Monitoring Board Installation and Configuration Inventory (1) (1) (3) (3) Note The branch current monitoring board can be installed only in a PDU with a serial number of XF0314 or higher.

More information

Integrated Metering Systems, Inc.

Integrated Metering Systems, Inc. Integrated Metering Systems, Inc. Models beginning with BL, S1, or S2 Individual Meters Product Guide Technical Specifications Installationn Instructions PN: 114-0004 Revision 1.0 List of Figures... 2

More information

BLU- CIF2 Interface Board

BLU- CIF2 Interface Board BLU- CIF2 Interface Board The BLU-CIF2 Interface Board simplifies the wiring of all of the BLU products to two BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination,

More information

Wa r n i n g-wa r n i n g-wa r n i n g

Wa r n i n g-wa r n i n g-wa r n i n g Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA SURGE PROTECTION DESIGN. Parallel Versus Series Protection. Surge protectors within the scope of this UFC should normally be of the parallel

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual APC 2X Series Hardwire Products PMP2X-A PMF2X-A PMG2X-A PMH2X-A APC hardwired products are designed to provide specification-grade performance at the service entrance,

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements installing the module connecting the wiring using the indicators for

More information

BLU- CIF Interface Board

BLU- CIF Interface Board BLU- CIF Interface Board The BLU-CIF Interface Board simplifies the wiring of all of the BLU products to the BSS Audio London Series Digital Signal Processors. It allows for Cat5e wiring termination, as

More information

Installing the Enphase IQ Commercial Envoy

Installing the Enphase IQ Commercial Envoy QUICK INSTALL GUIDE (Model ENV-IQ-AM3-3P) Installing the Enphase IQ Commercial Envoy To install the Enphase IQ Commercial Envoy, read and follow all warnings and instructions in this Guide and in the Enphase

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling installing the module short circuit protection using

More information

ReCon T Energy Logger. Installation and connection manual

ReCon T Energy Logger. Installation and connection manual ReCon T Energy Logger Installation and connection manual Content Index Important safety information... 4 Voltage and current inputs...5 Electric topologies...5 Installing your ReCon T Energy Logger...

More information

Series 3300 Multi-Function Meter with RS485 Communications

Series 3300 Multi-Function Meter with RS485 Communications Series 3300 Multi-Function Meter with RS485 Communications Series 3500 Multi-Function Meter with Ethernet Communications Installation and User s Manual Revision E 0XA6609-890000 Dated March 4, 2014 Table

More information

Installing the Cisco ATA

Installing the Cisco ATA CHAPTER 2 This section provides instructions for installing the Cisco ATA 186 and Cisco ATA 188. Before you perform the installation, be sure you have met the following prerequisites: Planned the network

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information