THE CRITICAL ROLE OF HIGH RESOLUTION X-RAY MICRO- COMPUTED TOMOGRAPHY FOR ULTRA-THIN WALL SPACE COMPONENT CHARACTERIZATION

Size: px
Start display at page:

Download "THE CRITICAL ROLE OF HIGH RESOLUTION X-RAY MICRO- COMPUTED TOMOGRAPHY FOR ULTRA-THIN WALL SPACE COMPONENT CHARACTERIZATION"

Transcription

1 THE CRITICAL ROLE OF HIGH RESOLUTION X-RAY MICRO- COMPUTED TOMOGRAPHY FOR ULTRA-THIN WALL SPACE COMPONENT CHARACTERIZATION D. J. Roth 1, R.W. Rauser 2, R. R. Bowman, 1 R.E. Martin 3, A. Koshti 4, David S. Morgan 1 1 NASA Glenn Research Center, Cleveland, OH University of Toledo, Toledo, OH Cleveland State University, Cleveland, OH NASA Johnson Space Center, Houston, TX ABSTRACT. A high resolution micro-computed tomography (μct) system complemented by specialized hardware and software tools were used to provide quantitative characterization for a tapered ultrathin wall space component at NASA. The CT data served two purposes: first to assess whether an acceptable flaw condition based on acceptable use requirements existed and second to provide comprehensive flaw measurements for life modeling. Regarding the latter, the measurements were used in a fracture-mechanicsbased model to determine whether the components would be expected to survive four service lifes. This article will describe component acceptance criteria; the CT system hardware and procedure; detectability and measurement error assessment of the CT system, specialized software needed to aid the characterization process; example CT results; correlation with optical/sem characterization; and an overview of the modeling technique utilizing the CT data. Keywords: Nondestructive Evaluation, NDE, computed tomography, Imaging, x-ray, metallic components, thin wall inspection INTRODUCTION Space missions of long duration with limited ability to use solar power often utilize radioisotopebased thermo-electric power systems [1,2]. The planetary science decadel survey committee determined that the completion and validation of the Advanced Stirling Radioisotope Generator (ASRG) is its highest priority for near term technology investment [1]. NASA, in partnership with the Department of Energy, Lockheed- Martin, and Sunpower Corp., is spearheading an effort to develop an ultra high efficiency, lower mass Stirling

2 convertor for use with a radioisotope, reactor, or solar concentrator heat source for power on beyond-earthorbit space missions. Although increasing both the temperature and pressure of the working fluid will place an increased burden on all components of the convertor, the thin wall complex-shaped heater head (essentially a pressure vessel containing the working gas helium) will be the most severely tested (see figure 1). Figure 1. Heater head component (within ellipsed area) in Advanced Stirling Converter. To withstand the temperatures and stresses imposed on this structure, the heater head for the ASRG unit is fabricated from a high-strength cast superalloy 247LC. The head has a very thin-walled section of proprietary dimension, and also contains a tapered region in which the wall gradually doubles in thickness. Being a cast alloy, it is likely that at least some regions of the starting material will contain defects such as porosity or deleterious phases. Many of these types of defects were found in design heads by destructive methods to be below the limit of detectability of conventional NDI (non destructive inspection) techniques that were previously available. To address this, NASA GRC assembled a state-of-the-art x-ray microcomputed tomography (μct) system for inspecting practically-sized components at very high resolution. The ability to detect these small defects is critical to the success of the program since all reliability and life predictions are based on the ability to reject parts with unacceptable levels of these features. This article focuses on the main aspects of μct interrogation of this component. ACCEPTANCE CRITERIA Based on initial modeling, flaw depth (regardless of flaw length) was the critical dimension determining the acceptability of the heater head for service within the ASRG. (As will be discussed in the section below entitled USE OF CT DATA FOR LIFE MODELING, acceptance criteria subsequently was modified to include life modeling using the CT data as inputs.) Based on the expected stresses and wall thickness in various portions of the heater head, and estimated error in the CT measurement of flaw dimensions, the critical flaw depth varies from 0.05 mm to mm for the wall region. (Wall thickness and taper profile are proprietary and will not be specifically defined in this article.) Smaller critical flaw depths are specified at the higher stress regions and larger critical flaw depths are specified at the lower stress

3 regions. Figure 2 shows a schematic of expected stresses without stress amplitudes or dimensions shown due to proprietary issues. Lower Stress Higher Stress Figure 2. Stress distribution schematic of tapered thin wall heater head component. Since it is somewhat impractical for the purposes of inspection analysis to partition the wall with regards to critical flaw depth exactly based on stress, the heater head critical flaw depth was based on linear regions as shown in table 1. Zone / (Range From Open End Name Critical Flaw Depth (mm) (mm)) A1 / (0 7.25) Weld Flange Section > 0.07 A2 / ( ) Thin Wall Section > 0.09 A3 ( ) Transition Section Between Thin > 0.05 Wall and Taper Wall Sections A4 ( ) Taper Wall Section > 0.09 B Weld Flange Parent Material > C Weld Flange Braze Joint AWS C3.6M / C3.6: 2008 Section Table 1. Division of heater head component wall into critical flaw depth zones. The American Welding Society Specification for Furnace Brazing, AWS C3.6M / C3.6: 2008 Section [3] is used for Zone C for the braze joint used to attach a weld ring to the head. This section states that radiographic record shall indicate that 1) the total measured void, or unbounded area, of the joint does not exceed 15% of the total joint area, 2) the width of the largest void or unbounded area as measured parallel to the joint width shall not exceed 60% of the total joint width and 3) any such void that is wider than 40% of the width of the joint shall extend no closer to either edge of the joint than 20% of the joint width. (A Helium leak test was also performed on the heater head as another test for acceptable use and will not be discussed in this article.) NASA GLENN RESEARCH CENTER CT SYSTEM The Microfocus X-ray Computed Tomography (μct) facility is a non-destructive imaging technique designed to inspect complex-shaped parts for micron scale flaws. Multiple x-ray projection images are acquired, followed by software reconstruction techniques using the projection images, to obtain crosssectional slices of the part. The cross-sectional images can be viewed individually or used to render a

4 volume. The source is an X-ray WorX XWT-225-THE microfocus X-ray 225 kev transmission tube (< 5 μm spot size, 25W power) that produces a cone beam. Typical Microfocus sources have spot size > 5 μm. The detector is a Dexela 2923 ( mm pitch, 29 x 23 cm area, and 3888 x 3072 pixel elements). This detector has nearly half of the pixel pitch of the commercial grade prior state-of-the-art detectors utilized for microfocus digital x-ray (typically μm). The acquisition, reconstruction, and visualization software is from NSI, Inc and 3M/Hytek, Inc. 4-axis motion control allows automated positioning and scanning. The system, shown in figure 3, has resolution capability > 30 line pair/mm. Figure 3. NASA Glenn Research Center X-ray CT system. An additional improvement to the system included the development of a reasonable-cost high resolution display system to evaluate μct results. Because the detector has ~ 12M elements, resulting slice images can be on the order of 4000 x 3000 pixels. Unwrapped images (to be discussed below) can be on the order of x 3000 pixels. This presents a significant difficulty for viewing images on a single 30 LCD panel display that would normally be considered high resolution (2560 x 1600 pixels). The large images are effectively downsampled automatically in order to view on such monitors, resulting in potential lost data, which was undesirable for this project. Because of this, NASA assembled a 4 x 30 display panel setup with dual video cards in an HP z800 workstation with 192 gbyte RAM resulting in 5120 x 3200 display resolution. The display is shown in figure 4. Even this is not fully adequate to view full resolution unwrapped images, but it helps greatly in image evaluation, and a display of eight large-size monitors required for no downsampling is likely impractical for any inspector to use for analysis.

5 Figure 4. Four 30 monitor visualization setup showing one unwrapped CT reslices for the heater head spanning the four monitors. (Upper left hand corner shows thumbnail image of a CT cross-sectional slice which when unwrapped results in the CT reslices shown spanning the four monitors.) UNWRAPPER/RESLICER SOFTWARE CT data visualization in the heater head presents an immense challenge from the human factors standpoint. This is because ultra-thin-wall metallic cylinders are extremely difficult to analyze for flaws from top-view cross-sectional CT slices and volume renderings. Top view slice images for the heater head are extremely difficult to evaluate for flaw indications because the wall is so thin, and extensive zooming and panning is required when viewing each slice. Additionally, the inner wall is ill-defined at the low voltage settings utilized (the lowest voltage possible was utilized while still achieving acceptable photon count at the detector in order to obtain optimal contrast for flaw detection (see figure 5)). (Higher voltage and lower current settings with total power near the tube power rating of 25W allows resolution of the inner wall at the expense of flaw contrast.) With thousands of slices, analysis using top view slices is totally impractical. Volume rendering grayscale, texture and contrast expansion schemes that highlight the flaws of interest also tend to highlight graphic anomalies in the cartoon-like renderings. Thus, it is difficult to separate flaw from graphic anomalies in the volume renderings. Computerized automatic flaw recognition was developed but proved only mildly successful due to widely varying flaw indication gray scale and also very slow for the large data sets. In general for cylindrical CT data flaw detection, it can be advantageous to unwrap and reslice the 360 o data so as to view 2-d sheets from the exterior to interior of the cylinder separated by the voxel dimension. For this work, it became essential to perform this process because flaws were so difficult to detect from both top view slices and volume renderings. NASA GRC developed dedicated cylindrical CT data unwrapper/reslicer software (CT-CURS) [4] for just this purpose. Accurate lateral dimensional analysis of flaw dimensions is only possible on the unwrapped sheets. Additionally, unwrapping allows the viewing of a reasonable number of large CT slices from exterior to interior of a cylindrical object. Further, there is no data set size restriction when using this software which is critical for the up-to-40 gbyte data sets for the heater head. To effectively unwrap and reslice the CT data, the cross-sectional CT slices must be histogram-matched and precisely aligned. Software to perform sub-voxel resolution alignment is included as a pre-processing step in CT-CURS. Each unwrapped reslice is contrast expanded between its minimum and maximum value, and flaws tend to jump out at the inspector on the reslices. Additionally, many image processing and quantitative analysis tools are available in the software to enhance flaw detectability and make flaw measurements. Perhaps the most significant of these is the ability to point and click on flaws on the unwrapped reslices. This results in the automated recall of the proper top view slice, and draws a line from

6 the center of the top view slice to the exact angular/polar location of the flaw on the slice. This protocol not only results in the ability to find flaws that would not be found using the top-view slices and volume renderings alone, but it also makes the process of locating and characterizing flaws, at minimum, an order of magnitude easier and faster. Figure 4 shows an unwrapped reslices spanning four monitors during an actual analysis. CT-CURS is available for download by U.S. citizens at Based on the advantages given, it has significant reward over unwrapping functions that might be found in commercial software. Figure 5. Top view CT slice of heater head showing the thin, ill-defined inner wall, and exploded view of an actual flaw found. This image illustrates the difficulty of inspecting top view CT slices for flaws. CT PROCEDURE The goal of the procedure was to achieve maximum magnification (and therefore maximum resolution) and maximum contrast, high photon flux at the detector for near-maximum dynamic range, high contrast-to-noise ratio, high signal-to-noise ratio, and do this at reasonable tube power settings. Sufficient power would be required in order to allow x-ray penetration through the weld ring (1mm thick) in addition to the wall thickness. The optimal voltage would provide good contrast while minimizing scattering. The final experimental parameters for the heater head were source-to-object distance = 150 mm, source-to-detector distance = 800 mm (~ 5.3x geometric magnification), 1800 projection images/views (minimizing aliasing), voltage = 70 kv and current = 200 μa (14W power), mm Cu filter in front of tube, 4 frames / sec acquisition, 4 frame averages, detector and geometric calibration for every scan, optimal sharpening prior to reconstruction, and Fast Feldkamp (FDK) reconstruction [5]. The sample stage and detector were precisionleveled. The head positioning resulted in a 14 μm voxel dimension. It also resulted in very large data sets up to 40 gbyte in size. A hypodermic needle end was attached at the bottom of each head as a known measurement reference in order to verify the accuracy of flaw measurements made on the CT images. A formal procedure document was written detailing the exact steps of inspection and analysis so that all flight heater heads would be inspected in an identical fashion.

7 PROBABILITY OF DETECTION A spare heater head of identical structure to actual heater heads had four artificial flaw patterns machined into its wall using a micro electrical discharge machining (micro-edm) procedure. Hole and slit patterns were machined into both the thin and taper wall regions using the micro-edm procedure with one hole pattern and one slit pattern in each region to create a calibration standard. The specification was for holes ranging in diameter from μm and ranging in depth from 60 μm to full wall penetration. The slits were to range in depth from μm, in width from μm, and in length from μm. Approximately 120 and 40 flaws were machined into the thin wall and taper wall (at location ~ 2.5x thickness of thin wall), respectively. The bottom of the flaws was reasonably flat. The machined flaws depths were measured using a combination of electrode encoder position as provided by the vendor and optical microscopy at NASA (and from CT measurements in a limited number of cases). The vendor specified a 1 2 μm depth accuracy while NASA expected a 5 10% depth measurement error in the optical measurement. Lateral dimensions were measured using scanning electron microscopy (SEM) with an estimate of 5 10% accuracy. CT depth measurement error was estimated overall between 10 30% (discussed below). A MIL-HDBK-1823 [6] probability of detection analysis of â versus flaw size a using POD 1823 software was performed to obtain a 90/95 (90 percent probability of detection at a 95 percent confidence level). â is defined as the measured response (signal contrast) of the NDE system to a flaw of flaw size a. For this analysis, flaws in the unwrapped reslices were analyzed for signal contrast and noise using a line profile technique. Figure 6 illustrates the definitions for signal contrast (S) and noise (N). Signal contrast was defined as the difference between the mean gray level in the line drawn through the center of the flaw (M) and the minimum gray level in the flaw area (maximum dip gray value) (d max ). Noise was defined as the difference between M and the minimum gray value on either side of the flaw. Lines were drawn that covered about 40 pixels. The reslice selected was the one where the operator saw maximum flaw contrast. Signal Contrast and Noise Definitions From Line Profile Left Background Region Right Background Region n max, left n max = Greater of n max, left and n max, right n max, right Mean Background Line (M) N = M n max S = M d max d max Signal contrast Quantities shown are Gray Values obtained from the Image Line Profile Figure 6. Definitions for signal contrast and noise used in POD analysis. All artificial flaws were detected. Figure 7 shows an enlarged view of micro-edm holes in the thin wall section.

8 1 mm Figure 7. Micro-EDM hole pattern (unwrapped-resliced CT view) in thin wall section near outer diameter surface. POD analysis required plotting signal contrast versus volume of the flaw since both depth and lateral dimensions will play a role in detectability. The micro-edm holes and slits were modeled as cylinders and rectangular boxes, respectively. For the POD analysis, a model is selected that provides the most linear relationship between signal contrast and volume. For this data, a linear (Y axis) log (X-axis) model provided the most linear relationship. Some data points were identified as outliers for the purpose of the analysis. Figure 8 shows signal contrast versus log (flaw volume) for the micro-edm holes in the thin wall region.

9 y = x R² = Contrast (gray value) C (gray value): Holes in Thin Wall Linear (C (gray value): Holes in Thin Wall) Log (Volume, um^3) Figure 8. Signal Contrast vs. Log (Flaw Volume) for the micro-edm holes in the thin wall region. The analysis also requires a decision threshold to be selected which is normally the lowest contrast value observed in the data set. The decision threshold is defined as the value of â above which the signal is interpreted as a hit, and below which the signal is interpreted as a miss. The decision threshold is the â value associated with 50% POD and is always greater than the inspection threshold (the lowest possible signal contrast that might be interpreted as a hit) [6]. Figure 9 shows Probability of Detection vs. Volume for the micro-edm holes in the thin wall region. The volumes for 50% POD, 90% POD, and 90% with 95% confidence bounds POD are shown.

10 Figure 9. Probability of Detection vs. Volume for the micro-edm holes in the thin wall region. Since signal contrast is plotted versus volume, it is required to back out POD flaw (lateral) sizes at individual depths. The depths selected are those in the range of the critical flaw depths of interest for the ASRG project. Table 2 shows the a 90/95 flaw sizes for the various flaw types and regions. For the holes, for a given depth, a diameter is derived. For the slits, for a given depth, different combinations of widths and lengths can be derived with several shown here. Since the tapered region is more than double the thickness of the thin wall region, it is not surprising that the a 90/95 flaw size is larger in this region for the holes and slits versus a 90/95 in the thin wall region as shown in the table. The a 90/95 flaw size values shown in the tables are consistent with what the inspector analyst considered very detectable flaws after training. Region Depth (μm) a 90/95 (μm) Diameter a 90/95 (μm) Width a 90/95 (μm) Length Holes in Thin Wall Region n/a n/a Holes in Tapered n/a n/a

11 Wall Region Slits in Thin Wall Region Slits in Thin Wall Region Slits in Thin Wall Region 60 n/a n/a n/a Slits in Tapered 80 n/a Wall Region Slits in Tapered 80 n/a Wall Region Slits in Tapered Wall Region 80 n/a Table 2. a 90/95 Flaw Sizes for micro-edm flaws. Noise is utilized in the analysis of false call rates. Table 3 shows very low false call rates for the four regions. Region False Call Rate (%) Holes in Thin Wall Region 3.1 Holes in Tapered Wall Region 0 Slits in Thin Wall Region 0.4 Slits in Tapered Wall Region 0.16 Table 3. False Call Rates for micro-edm flaws. A more detailed presentation of the POD analysis will be provided in a later publication. MEASUREMENT ACCURACY For nearly all of the flaws in the calibration standard, measurement of depth and lateral dimensions was performed using the top view CT slices (after point and click feature allowed automated recall of the proper top view slice) and unwrapped reslices, respectively. Measurement was made manually by drawing a line the dimension of the flaw to the best of the operator s ability. The manual method limits the measurement accuracy at best to the size of the voxel / pixel dimension. Automated edge detection methods to find flaw boundaries were considered that would provide sub-voxel / pixel resolution. Those methods rely heavily on proper contrast between flaw and background and were not practical for measurements on actual flaws, though possibly would have worked well on many of the micro-edm flaws. The true measurement value was considered to be from vendor-supplied depth profiling (depth) and scanning electron microscope dimensional analysis (lateral dimensions) (although it has been estimated that the SEM measurements have potentially 5 10% error as well). The error in the CT measurements was computed from: % 100 (1) Where is the CT measurement and are the measurements from vendor depth profiling (depth) and scanning electron microscope dimensional analysis (lateral dimensions). Table 4 shows the mean + standard deviation (SD) error in CT measurements of dimensions for the flaws in the different regions.

12 Region / Number of Measurements Holes in Thin Wall Region / 66 Holes in Tapered Wall Region / 21 Slits in Thin Wall Region / 62 Mean + SD Error in Depth Measurement (%) Mean + SD Error in Diameter Measurement (%) Mean + SD Error in Length Measurement (%) Mean + SD Error in Width Measurement (%) n/a n/a n/a n/a n/a Slits in Tapered Wall Region / n/a Table 4. Percent Mean + Standard Deviation (SD) Error in CT measurements of Dimensions Using Manual Measurement by CT Operator. Computations are rounded to nearest whole number. Note that the mean % error in depth (critical flaw) dimension was at or near 10% with ~ 10% standard deviation. Lateral measurement % error was between 10% and 35% with standard deviation % error ranging from 10% to 22%. These are large standard deviations that represent a significant spread in the CT measurement accuracy. The spread is illustrated in figure 10 which shows the % error in CT depth measurement vs. hole number for the holes in the thin wall region. The trend line in figure 10 hovers near the observed mean % error (10%). % Error CT Depth Error (%) vs. Hole Number Trend line Hole Number Figure 10. % Error in CT depth measurement vs. Hole number. RESULTS ON ACTUAL HEATER HEADS Figure 11 shows CT results from several of the flight heater heads. The flaws found in the heads were determined to be primarily oxide inclusions of various compositions (see section entitled CORRELATION OF CT RESULTS WITH OPTICAL AND SEM RESULTS ) as a result of the casting process. (By viewing these flaws it is apparent that a threshold-based automatic flaw recognition scheme would not be practical due to the differing gray scales of the flaws against an image that itself contains gray scale variation (noise).)

13 . Unwrapped Reslice View (Length) Top View (Depth) z 5.0 mm Oxide r mm Oxide 0.54 mm Oxide mm Oxide 0.40 mm Oxide mm Oxide Figure 11. CT results showing lateral and depth views of three flaws in actual heater head sample. Lateral size and depth are provided from measurements in the unwrapped reslices and top views, respectively, where z is the axial direction upward and r is radial direction. CORRELATION OF CT RESULTS WITH OPTICAL AND SEM RESULTS For the flight heater heads that failed CT inspection and could be sectioned, excellent correlation between lateral flaw indications from the CT unwrap reslices and optical and scanning electron microscope (SEM) results was consistently observed (as seen in figure 12).

14 CT Unwrap View / Reslice Appearance of the Major Flaw Using Different Imaging Techniques Optical SEM Both the optical and SEM images suggest that the defect is not porosity but rather a solid phase of some type. Figure 12. Correlation between CT, Optical, and SEM results. 16 BRAZE JOINT EVALUATION The porosity fraction of the braze joint was evaluated per American Welding Society Specification for Furnace Brazing, AWS C3.6M / C3.6: 2008 Section [3] using the unwrapped reslice where the pores became most focused. The braze joint is about 0.2 mm thick and the CT does an excellent job of characterizing pore fraction, size, and location as shown in figure 9 for a development heater head. The CT- CURS software has a binary threshold image processing operation to binarize the images, followed by an automated areal fraction quantitative image analysis to calculate porosity fraction. In the example shown in figure 13, even though there is significant porosity in one area of the braze joint, the % porosity in the entire braze joint is only 2.2%. However, the near inter-connectedness of porosity of several regions would likely have resulted in failure to meet the AWS specification (the width of the largest void or unbounded area as measured parallel to the joint width shall not exceed 60% of the total joint width and / or any such void that is wider than 40% of the width of the joint shall extend no closer to either edge of the joint than 20% of the joint width).

15 Sample CT Results Unwrapped View One Reslice 2.2% Porosity Binary thresholding of entire braze joint area, coloring porosity red and all other material colored black Figure 13. CT volume rendering, unwrapped reslices view, and magnified view of braze joint porosity. Braze joint region of image is binarized using threshold method and areal fraction of porosity automatically calculated in CT-CURS. The % porosity in the entire braze joint is 2.2%. USE OF CT DATA FOR LIFE MODELING The ASRG program later required the inspection analyst to measure as accurately as possible flaw depth, flaw length, angle from vertical, X and Y location, and distance from open end. The CT results were used as inputs to analytical modeling which determines whether a flaw(s) in a heater head will create a leak path within four service lifes. If the model predicted such a leak path, the heater head could not be placed into flight service. The model was fracture mechanics-based and required calculation of a damage index that was dependent on the total number of expected loading events, the number of expected cycles for each event (such as from cyclical vibration loads during rocket launching), applied stress, flaw geometry, and component geometry). If the damage index > 1.0, leaking is expected with four service lifes. If the damage index << 1.0, leaking is not expected with four service lifes. This modeling effort requires accurate flaw morphology information which can only be obtained practically using high resolution Microfocus CT. CONCLUSIONS A high resolution micro-computed tomography (μct) system complemented by specialized hardware and software tools were used to provide quantitative characterization for a tapered ultra-thin wall space component at NASA. The CT data served two purposes: first to assess whether an acceptable flaw condition based on requirements existed and second to provide comprehensive flaw measurements for life modeling. No other characterization options are practical or possible for such a complex-shaped component requiring high fidelity measurements. POD characterization and measurement accuracy of the method were assessed. The CT method should be considered essential for characterization of high-performance reasonably-sized components in critical aerospace applications.

16 REFERENCES 1. NASA Space Technology Roadmaps and Priorities: Restoring NASA s Technological Edge and Paving the Way for a New Era in Space, National Research Council, National Academy Press, Washington, D.C., Elmo, T., Advanced Stirling Radioisotope Generator, Loc Publishing, Specification for Furnace Brazing, AWS specification C3.6M/C3.6:2008, Section 6.5.2, American Welding Society, Roth, D.J., Burke, E.R., Rauser, R.W., and Martin, R.E., A Novel Automated Method For Analyzing Cylindrical Computed Tomography Data, Extended Abstract Paper Proceedings at Fall 2011 ASNT conference. Palm Springs Convention Center, Palm Springs, California. October Pp Feldkamp, L.A., Davis, L.C., and Kress, J.W., Practical cone-beam algorithm, J. Opt. Soc. Amer. A6 (1984), MIL-HDBK-1823, DEPARTMENT OF DEFENSE HANDBOOK: NONDESTRUCTIVE EVALUATION (NDE) SYSTEM, RELIABILITY ASSESSMENT (30 APR 1999).

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling nd International Symposium on NDT in Aerospace - We..A. Comparison of Probing Error in Dimensional Measurement by Means of D Computed Tomography with Circular and Helical Sampling Jochen HILLER, Stefan

More information

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY David K. Lehmann 1, Kathleen Brockdorf 1 and Dirk Neuber 2 1 phoenix x-ray Systems + Services Inc. St. Petersburg, FL, USA 2 phoenix x-ray Systems + Services

More information

Recognition and Measurement of Small Defects in ICT Testing

Recognition and Measurement of Small Defects in ICT Testing 19 th World Conference on Non-Destructive Testing 2016 Recognition and Measurement of Small Defects in ICT Testing Guo ZHIMIN, Ni PEIJUN, Zhang WEIGUO, Qi ZICHENG Inner Mongolia Metallic Materials Research

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control Oliver BRUNKE 1,

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 6 th International Congress of Metrology, 06003 (203) DOI: 0.05/ metrology/20306003 C Owned by the authors, published by EDP Sciences, 203 A new Concept for High-Speed atline and inlinect for up to 00%

More information

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field Kouichi Inagaki ICC / IHI Corporation 13 th WORLD CONFERENCE ON INVESTMENT CASTING Paper: T3 Copyright

More information

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY VERIFICATION AND ANALYSIS M. L. Hsiao and J. W. Eberhard CR&D General Electric Company Schenectady, NY 12301 J. B. Ross Aircraft Engine - QTC General

More information

3D Computed Tomography (CT) Its Application to Aerospace Industry

3D Computed Tomography (CT) Its Application to Aerospace Industry 3D Computed Tomography (CT) Its Application to Aerospace Industry C. Muralidhar, M. P. Subramanian, V. Ravi Shankar and G. Chandrasekhar Directorate of Non Destructive Evaluation, Defence Research & Development

More information

Simulation of Radiographic Testing for POD Assessment

Simulation of Radiographic Testing for POD Assessment 4th European-American Workshop on Reliability of NDE - Th.5.B.2 Simulation of Radiographic Testing for POD Assessment Gerd-Rüdiger JAENISCH, Carsten BELLON, Uwe EWERT, BAM, Berlin, Germany Abstract. Efficient

More information

Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures

Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures 4th International Symposium on NDT in Aerospace 2012 - Th.1.A.1 Simulation Supported POD Methodology and Validation for Automated Eddy Current Procedures Anders ROSELL, Gert PERSSON Volvo Aero Corporation,

More information

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies ECNDT 2006 - Th.3.4.2 Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies M. SIMON, I. TISEANU, C. SAUERWEIN Hans WÄLISCHMILLER, Meersburg, Germany M. SINDEL, M. BRODMANN,

More information

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image

More information

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM M. Simon, C. Sauerwein, I. Tiseanu, S. Burdairon Hans Wälischmiller GmbH Klingleweg 8, D-88709 Meersburg, Germany e-mail: ms@hwm.com ABSTRACT A new flexible

More information

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis Oliver Brunke 1, Ferdinand Hansen 2, Ingo Stuke 3, Friedrich

More information

Digital Volume Correlation for Materials Characterization

Digital Volume Correlation for Materials Characterization 19 th World Conference on Non-Destructive Testing 2016 Digital Volume Correlation for Materials Characterization Enrico QUINTANA, Phillip REU, Edward JIMENEZ, Kyle THOMPSON, Sharlotte KRAMER Sandia National

More information

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald

More information

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.1 Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications Malte KURFISS 1, Gerd STRECKENBACH 2 1 YXLON International

More information

MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM

MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM BILLETS UTILIZING CT X-RAY AND ULTRASONIC IMAGING Mano Bashyam and Vi Sub GE Aircraft Engines, Mail Drop Q45 1, Neumann Way Cincinnati, OH 45215

More information

Ch 22 Inspection Technologies

Ch 22 Inspection Technologies Ch 22 Inspection Technologies Sections: 1. Inspection Metrology 2. Contact vs. Noncontact Inspection Techniques 3. Conventional Measuring and Gaging Techniques 4. Coordinate Measuring Machines 5. Surface

More information

CIVA Computed Tomography Modeling

CIVA Computed Tomography Modeling CIVA Computed Tomography Modeling R. FERNANDEZ, EXTENDE, France S. LEGOUPIL, M. COSTIN, D. TISSEUR, A. LEVEQUE, CEA-LIST, France page 1 Summary Context From CIVA RT to CIVA CT Reconstruction Methods Applications

More information

Implementation of Automated 3D Defect Detection for Low Signal-to Noise Features in NDE Data

Implementation of Automated 3D Defect Detection for Low Signal-to Noise Features in NDE Data Implementation of Automated 3D Defect Detection for Low Signal-to Noise Features in NDE Data R. Grandin and J. Gray Center for NDE, Iowa State University, 1915 Scholl Road, Ames, IA 50011 USA Abstract.

More information

Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts

Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts ASTM Workshop on Mechanical Behavior of Additive Manufactured Components May 4,

More information

John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc., New Richmond, WI

John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc., New Richmond, WI Enhanced Defect Detection on Aircraft Structures Automatic Flaw Classification Software (AFCS) John R. Mandeville Senior Consultant NDICS, Norwich, CT Jesse A. Skramstad President - NDT Solutions Inc.,

More information

12X Zoom. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts.

12X Zoom. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts. Incredible 12X (0.58-7X) magnification for inspection of a wider range of parts. Telecentric attachment gives you the world s first parfocal telecentric zoom lens with field coverage up to 50 mm. Increased

More information

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers By Jeffrey L. Guttman, Ph.D., Director of Engineering, Ophir-Spiricon Abstract: The Mode-Field Diameter (MFD) and spot

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array

Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array Sizing and evaluation of planar defects based on Surface Diffracted Signal Loss technique by ultrasonic phased array A. Golshani ekhlas¹, E. Ginzel², M. Sorouri³ ¹Pars Leading Inspection Co, Tehran, Iran,

More information

Simulation Based POD Estimation for Radiographic Testing of Turbine Blades

Simulation Based POD Estimation for Radiographic Testing of Turbine Blades 5 th European-American Workshop on Reliability of NDE Lecture 12 Simulation Based POD Estimation for Radiographic Testing of Turbine Blades Hans-Uwe BARON *, Benjamin HENKEL *, Carsten BELLON **, Andreas

More information

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE

NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE NDT OF SPECIMEN OF COMPLEX GEOMETRY USING ULTRASONIC ADAPTIVE TECHNIQUES - THE F.A.U.S.T. SYSTEM INTRODUCTION O. Roy, S. Mahaut, M. Serre Commissariat a I'Energie Atomique CEAlCEREM, CE Saclay France Phased

More information

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection Mariusz Jedrychowski EN/MME-MM Introduction of new technique at CERN 12/12/2017

More information

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components J. Luebbehuesen GE Sensing & Inspection Technologies GmbH, phoenix x-ray, Niels-Bohr-Str.

More information

Global to Local Model Interface for Deepwater Top Tension Risers

Global to Local Model Interface for Deepwater Top Tension Risers Global to Local Model Interface for Deepwater Top Tension Risers Mateusz Podskarbi Karan Kakar 2H Offshore Inc, Houston, TX Abstract The water depths from which oil and gas are being produced are reaching

More information

2. Equipment, specimens and inspection procedures

2. Equipment, specimens and inspection procedures 4th International CANDU In-service Inspection Workshop and NDT in Canada 2012 Conference, 2012 June 18-21, Toronto, Ontario Improved Flaw Characterization and Sizing in Pressure Tubes Alex KARPELSON Kinectrics

More information

Industrial Computed Tomography Innovations

Industrial Computed Tomography Innovations GE Inspection Technologies Industrial Computed Tomography Innovations Premium performance for premium quality and speed. gemeasurement.com/ct Premium CT technologies. Faster than ever before. Every industrial

More information

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS A. Campos a*, A. Zorrilla a, F. Lasagni a a Materials & Processes dept., Center for Advanced Aerospace Technologies

More information

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct J. DHAENE* 1, E. PAUWELS 1, T. DE SCHRYVER 1, A. DE MUYNCK 1, M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics

More information

Impact of 3D Laser Data Resolution and Accuracy on Pipeline Dents Strain Analysis

Impact of 3D Laser Data Resolution and Accuracy on Pipeline Dents Strain Analysis More Info at Open Access Database www.ndt.net/?id=15137 Impact of 3D Laser Data Resolution and Accuracy on Pipeline Dents Strain Analysis Jean-Simon Fraser, Pierre-Hugues Allard Creaform, 5825 rue St-Georges,

More information

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS P. Helberg 1,

More information

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects Tong LIU 1, Brian Stephan WONG 2, Tai

More information

Phased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability

Phased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability 19 th World Conference on Non-Destructive Testing 2016 Phased Array Assisted Manual Nozzle Inspection Solution with Data Archiving Capability Jason HABERMEHL 1, Nicolas BADEAU 1, Martin ST-LAURENT 1, Guy

More information

Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage

Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage Downloaded from orbit.dtu.dk on: Apr 10, 2018 Micro-CT in situ study of carbonate rock microstructural evolution for geologic CO2 storage Zheng, Yi; Yang, Yan; Rogowska, M.; Gundlach, Carsten Published

More information

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 Revised 10/10 COURSE SYLLABUS TM 220 COMPUTED TOMOGRAPHY PHYSICS CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0 CATALOG COURSE DESCRIPTION: This course is one of a three course set in whole body Computed

More information

GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES

GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES GENERAL AUTOMATED FLAW DETECTION SCHEME FOR NDE X-RAY IMAGES Karl W. Ulmer and John P. Basart Center for Nondestructive Evaluation Department of Electrical and Computer Engineering Iowa State University

More information

MANUFACTURING OPTIMIZING COMPONENT DESIGN

MANUFACTURING OPTIMIZING COMPONENT DESIGN 82 39 OPTIMIZING COMPONENT DESIGN MANUFACTURING SIMULATION OF LASER WELDING SHORTENS DESIGN CYCLE AND OPTIMIZES COMPONENT DESIGN AT OWENS CORNING JOHN KIRKLEY interviews BYRON BEMIS of Owens Corning It

More information

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

The new generation of industrial computed tomography. The Desktop CT exact S

The new generation of industrial computed tomography. The Desktop CT exact S The new generation of industrial computed tomography The Desktop CT S Volume scanning technology Innovation with a family tradition Founded in 1968, the family-owned, WEN- ZEL Metrology Group is one of

More information

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Tasuku Ito 1, Yutaka Ohtake 1, Yukie Nagai 2, Hiromasa Suzuki 1 More info about this article: http://www.ndt.net/?id=23662

More information

Probability of Detection Simulations for Ultrasonic Pulse-echo Testing

Probability of Detection Simulations for Ultrasonic Pulse-echo Testing 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Probability of Detection Simulations for Ultrasonic Pulse-echo Testing Jonne HAAPALAINEN, Esa LESKELÄ VTT Technical

More information

How does the ROI affect the thresholding?

How does the ROI affect the thresholding? How does the ROI affect the thresholding? Micro-computed tomography can be applied for the visualization of the inner structure of a material or biological tissue in a non-destructive manner. Besides visualization,

More information

Developing an Ultrasonic NDE System for a Research Reactor Tank

Developing an Ultrasonic NDE System for a Research Reactor Tank Developing an Ultrasonic NDE System for a Research Reactor Tank Y. Perets, E. Brosh, M. Ghelman, N. Moran, Y. Drymer, Y. Kadmon, S. Dahan Nuclear Research Center - Negev (NRCN), Beer-Sheva, Israel Abstract.

More information

How to Use the Luminit LSD Scatter Model

How to Use the Luminit LSD Scatter Model How to Use the Luminit LSD Scatter Model Summary: This article describes the characteristics and use of Luminit s LSD scatter model in OpticStudio. The scatter model presented here is the idealized scatter

More information

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh et al. : Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh V Acharya, Umesh Kumar, Gursharan

More information

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa TOWARDS ESTABLISHMENT OF STANDARDIZED PRACTICE FOR ASSESSMENT OF SPATIAL RESOLUTION AND CONTRAST OF INTERNATIONAL

More information

Identification of Shielding Material Configurations Using NMIS Imaging

Identification of Shielding Material Configurations Using NMIS Imaging Identification of Shielding Material Configurations Using NMIS Imaging B. R. Grogan, J. T. Mihalczo, S. M. McConchie, and J. A. Mullens Oak Ridge National Laboratory, P.O. Box 2008, MS-6010, Oak Ridge,

More information

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection Coherent Gradient Sensing Microscopy: Microinterferometric Technique for Quantitative Cell Detection Proceedings of the SEM Annual Conference June 7-10, 010 Indianapolis, Indiana USA 010 Society for Experimental

More information

Supplementary Materials for

Supplementary Materials for www.advances.sciencemag.org/cgi/content/full/1/3/e1400199/dc1 Supplementary Materials for Life and death of a single catalytic cracking particle Florian Meirer, Sam Kalirai, Darius Morris, Santosh Soparawalla,

More information

THE EVOLUTION AND APPLICATION OF ASYMMETRICAL IMAGE FILTERS FOR QUANTITATIVE XCT ANALYSIS

THE EVOLUTION AND APPLICATION OF ASYMMETRICAL IMAGE FILTERS FOR QUANTITATIVE XCT ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 THE EVOLUTION AND APPLICATION OF ASYMMETRICAL IMAGE FILTERS FOR QUANTITATIVE XCT ANALYSIS N. L. Rupert 1, J. M. Wells 2, W.

More information

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY BACKSCATTER DATA Young S. Ham and C.F. Poranski Materials Chemistry Branch Naval Research Laboratory Washington DC 20375 E.C. Greenawald Geo-Centers,

More information

VALIDATION OF THE SIMULATION SOFTWARE CIVA UT IN SEPARATED TRANSMIT/RECEIVE CONFIGURATIONS

VALIDATION OF THE SIMULATION SOFTWARE CIVA UT IN SEPARATED TRANSMIT/RECEIVE CONFIGURATIONS VALIDATION OF THE SIMULATION SOFTWARE CIVA UT IN SEPARATED TRANSMIT/RECEIVE CONFIGURATIONS Fabrice FOUCHER 1, Sébastien LONNE 1, Gwénaël TOULLELAN 2, Steve MAHAUT 2, Sylvain CHATILLON 2, Erica SCHUMACHER

More information

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Caroline Vienne 1, Marius Costin 1 More info about this article: http://www.ndt.net/?id=21917 1 CEA, LIST, Département

More information

Automation of Static and Dynamic FEA Analysis of Bottomhole Assemblies

Automation of Static and Dynamic FEA Analysis of Bottomhole Assemblies Automation of Static and Dynamic FEA Analysis of Bottomhole Assemblies Nader E. Abedrabbo, Lev Ring & Raju Gandikota 1 Weatherford International 11909 Spencer Road, Houston, TX nader.abedrabbo@weatherford.com

More information

The Electrochemical Innovation Lab X-ray Suite: from macro- to nano-ct

The Electrochemical Innovation Lab X-ray Suite: from macro- to nano-ct The Electrochemical Innovation Lab X-ray Suite: from macro- to nano-ct Dr. Francesco Iacoviello, Toby Neville & the Electrochemical Innovation Lab f.iacoviello@ucl.ac.uk MANIFEST - 2017 November 10 th,

More information

ASME Verification and Validation Symposium May 13-15, 2015 Las Vegas, Nevada. Phillip E. Prueter, P.E.

ASME Verification and Validation Symposium May 13-15, 2015 Las Vegas, Nevada. Phillip E. Prueter, P.E. VVS2015-8015: Comparing Closed-Form Solutions to Computational Methods for Predicting and Validating Stresses at Nozzle-to-Shell Junctions on Pressure Vessels Subjected to Piping Loads ASME Verification

More information

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Wenjuan Sun and Stephen Brown 10 th May 2016 1 Possible factors influencing XCT measurements Components Influencing variables Possible

More information

ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY

ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY William P. Winfree a,noreen A. Cmar-Mascis b, F. Raymond Parker a a NASA Langley Research Center, MS 231, Hampton VA 23681-2199

More information

High Resolution Phased Array Imaging using the Total Focusing Method

High Resolution Phased Array Imaging using the Total Focusing Method High Resolution Phased Array Imaging using the Total Focusing Method S. Kierspel, Wolfram A. Karl Deutsch, Helge Rast, Philippe Benoist 1, Venkat A 2 KARL DEUTSCH Pruef- und Messgeraetebau GmbH + Co KG

More information

CARBON NANOTUBE FLAT PLATE BLACKBODY CALIBRATOR. John C. Fleming

CARBON NANOTUBE FLAT PLATE BLACKBODY CALIBRATOR. John C. Fleming CARBON NANOTUBE FLAT PLATE BLACKBODY CALIBRATOR John C. Fleming Ball Aerospace, jfleming@ball.com Sandra Collins, Beth Kelsic, Nathan Schwartz, David Osterman, Bevan Staple Ball Aerospace, scollins@ball.com

More information

P recise Eye. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection.

P recise Eye. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection. High resolution, diffraction-limited f/4.5 optical quality for high precision measurement and inspection. Long working distance makes lighting and handling easier. Compact size. Coaxial lighting available

More information

Ultrasonic Multi-Skip Tomography for Pipe Inspection

Ultrasonic Multi-Skip Tomography for Pipe Inspection 18 th World Conference on Non destructive Testing, 16-2 April 212, Durban, South Africa Ultrasonic Multi-Skip Tomography for Pipe Inspection Arno VOLKER 1, Rik VOS 1 Alan HUNTER 1 1 TNO, Stieltjesweg 1,

More information

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Combining Analytical and Monte Carlo Modelling for Industrial Radiology 19 th World Conference on Non-Destructive Testing 2016 Combining Analytical and Monte Carlo Modelling for Industrial Radiology Carsten BELLON, Gerd-Rüdiger JAENISCH, Andreas DERESCH BAM Bundesanstalt für

More information

Using Edge Detection in Machine Vision Gauging Applications

Using Edge Detection in Machine Vision Gauging Applications Application Note 125 Using Edge Detection in Machine Vision Gauging Applications John Hanks Introduction This application note introduces common edge-detection software strategies for applications such

More information

VIBROACOUSTIC MODEL VALIDATION FOR A CURVED HONEYCOMB COMPOSITE PANEL

VIBROACOUSTIC MODEL VALIDATION FOR A CURVED HONEYCOMB COMPOSITE PANEL VIBROACOUSTIC MODEL VALIDATION FOR A CURVED HONEYCOMB COMPOSITE PANEL AIAA-2001-1587 Ralph D. Buehrle and Jay H. Robinson ÿ NASA Langley Research Center, Hampton, Virginia and Ferdinand W. Grosveld Lockheed

More information

Phased-array applications for aircraft maintenance: fastener-hole inspection

Phased-array applications for aircraft maintenance: fastener-hole inspection Phased-array applications for aircraft maintenance: fastener-hole inspection Guillaume Neau 1, Emmanuel Guillorit 2, Luc Boyer 2 and Herve Tretout 2 1 BERCLI Phased Array Solutions, Berkeley, CA94703,

More information

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

Using X-Ray Micro Tomography to assess the quality of Packaging Foil Using X-Ray Micro Tomography to assess the quality of Packaging Foil Martin Koster 1, Gerard van Dalen 2, Robert Hoeve 3 1 Unilever Research 2 Unilever Research 3 Unilever Research, Olivier van Noortlaaan

More information

Digital Image Processing

Digital Image Processing Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture

More information

3D X-ray Microscopy Characterization. Metal Additively Manufactured Parts. Application Note

3D X-ray Microscopy Characterization. Metal Additively Manufactured Parts. Application Note 3D X-ray Microscopy Characterization Metal Additively Manufactured Parts Application Note 3D X-ray Microscopy Characterization Metal Additively Manufactured Parts Author: Luke Hunter ZEISS X-ray Microscopy

More information

Comparison of Experimental and Model Based POD in a Simplified Eddy Current Procedure

Comparison of Experimental and Model Based POD in a Simplified Eddy Current Procedure 18th World Conference on Nondestructive Testing, 16-2 April 212, Durban, South Africa Comparison of Experimental and Model Based POD in a Simplified Eddy Current Procedure Anders ROSELL 1, Gert PERSSON

More information

Chapter 3. Experimental Procedure

Chapter 3. Experimental Procedure Chapter 3 Experimental Procedure 33 3.1 Burner Systems Startup 3.1.1 Instrumentation power up The instrumentation of the burner including the PC need to be turned on, in order to provide safe ignition

More information

Micro-CT in geosciences: Getting the inside story. Wesley De Boever

Micro-CT in geosciences: Getting the inside story. Wesley De Boever Micro-CT in geosciences: Getting the inside story Wesley De Boever November 24, 2016 Bruker microct Micro-CT scanner manufacturer Life science and material science Hardware and software Headquarters in

More information

2018 Technical Review Waruna Seneviratne, John Tomblin, and Supun Kariyawasam

2018 Technical Review Waruna Seneviratne, John Tomblin, and Supun Kariyawasam Analytical Fatigue Life Determination based on Residual Strength Degradation of Composites Damage Tolerance Testing and Analysis Protocols for Full-Scale Composite Airframe Structures under Repeated Loading

More information

Robot-based real-time ultrasonic tomography for industrial NDT applications

Robot-based real-time ultrasonic tomography for industrial NDT applications 1 Robot-based real-time ultrasonic tomography for industrial NDT applications Dr. Andrey Bulavinov I-Deal Technologies GmbH 2 Content I. Introduction of I-Deal Technologies GmbH I-Deal Spin-Off of Fraunhofer-IZFP

More information

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners Charles R. Smith, Kevin Holt BIR, Inc. Uwe Bischoff, Bernd Georgi, Ferdinand Hansen, Frank Jeltsch Volkswagen Commercial Vehicles

More information

SIZING THE HEIGHT OF DISCONTINUITIES, THEIR CHARACTERISATION IN PLANAR / VOLUMETRIC BY PHASED ARRAY TECHNIQUE BASED ON DIFFRACTED ECHOES

SIZING THE HEIGHT OF DISCONTINUITIES, THEIR CHARACTERISATION IN PLANAR / VOLUMETRIC BY PHASED ARRAY TECHNIQUE BASED ON DIFFRACTED ECHOES 1 1 SIZING THE HEIGHT OF DISCONTINUITIES, THEIR CHARACTERISATION IN PLANAR / VOLUMETRIC BY PHASED ARRAY TECHNIQUE BASED ON DIFFRACTED ECHOES G. Nardoni, M. Certo, P. Nardoni, M. Feroldi, D. Nardoni I&T

More information

Comparison of fiber orientation analysis methods in Avizo

Comparison of fiber orientation analysis methods in Avizo Comparison of fiber orientation analysis methods in Avizo More info about this article: http://www.ndt.net/?id=20865 Abstract Rémi Blanc 1, Peter Westenberger 2 1 FEI, 3 Impasse Rudolf Diesel, Bât A, 33708

More information

Product Information Version 1.1. ZEISS Xradia 510 Versa Submicron X-ray Imaging: Maintain High Resolution Even at Large Working Distances

Product Information Version 1.1. ZEISS Xradia 510 Versa Submicron X-ray Imaging: Maintain High Resolution Even at Large Working Distances Product Information Version 1.1 ZEISS Xradia 510 Versa Submicron X-ray Imaging: Maintain High Resolution Even at Large Working Distances Breakthrough Flexibility for 3D Submicron Imaging Achieve new levels

More information

A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES

A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES A RADIAL WHITE LIGHT INTERFEROMETER FOR MEASUREMENT OF CYLINDRICAL GEOMETRIES Andre R. Sousa 1 ; Armando Albertazzi 2 ; Alex Dal Pont 3 CEFET/SC Federal Center for Technological Education of Sta. Catarina

More information

Advanced materials research using the Real-Time 3D Analytical FIB-SEM 'NX9000'

Advanced materials research using the Real-Time 3D Analytical FIB-SEM 'NX9000' SCIENTIFIC INSTRUMENT NEWS 2017 Vol. 9 SEPTEMBER Technical magazine of Electron Microscope and Analytical Instruments. Technical Explanation Advanced materials research using the Real-Time 3D Analytical

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique Phase gradient microscopy in thick tissue with oblique back-illumination Tim N Ford, Kengyeh K Chu & Jerome Mertz Supplementary Figure 1: Comparison of added versus subtracted raw OBM images 45 µm polystyrene

More information

Medical Image Processing: Image Reconstruction and 3D Renderings

Medical Image Processing: Image Reconstruction and 3D Renderings Medical Image Processing: Image Reconstruction and 3D Renderings 김보형 서울대학교컴퓨터공학부 Computer Graphics and Image Processing Lab. 2011. 3. 23 1 Computer Graphics & Image Processing Computer Graphics : Create,

More information

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada

ULTRASONIC TESTING AND FLAW CHARACTERIZATION. Alex KARPELSON Kinectrics Inc., Toronto, Canada ULTRASONIC TESTING AND FLAW CHARACTERIZATION Alex KARPELSON Kinectrics Inc., Toronto, Canada 1. Introduction Ultrasonic Testing (UT) is a commonly used inspection method. Various techniques are employed

More information

STATUS 5. A Reliability Assessment Tool For NDT Inspection Systems

STATUS 5. A Reliability Assessment Tool For NDT Inspection Systems STATUS 5 A Reliability Assessment Tool For NDT Inspection Systems STATUS 5 Overview Introduction Advantages Introduction STATUS 5 is a convenient NDT tool for assessing the efficiency and reliability of

More information

Translational Computed Tomography: A New Data Acquisition Scheme

Translational Computed Tomography: A New Data Acquisition Scheme 2nd International Symposium on NDT in Aerospace 2010 - We.1.A.3 Translational Computed Tomography: A New Data Acquisition Scheme Theobald FUCHS 1, Tobias SCHÖN 2, Randolf HANKE 3 1 Fraunhofer Development

More information

Development of an automated bond verification system for advanced electronic packages

Development of an automated bond verification system for advanced electronic packages Development of an automated bond verification system for advanced electronic packages Michel Darboux, Jean-Marc Dinten LETI (CEA - Technologies AvancSes) - DSYS/SCSI CENG, 17 rue des Martyrs F38054 Grenoble

More information

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems. Slide 1 Technical Aspects of Quality Control in Magnetic Resonance Imaging Slide 2 Compliance Testing of MRI Systems, Ph.D. Department of Radiology Henry Ford Hospital, Detroit, MI Slide 3 Compliance Testing

More information

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL R. Hanke 1, A. Kugel 2, and P. Troup 2 1 Fraunhofer-Entwicklungszentrum für Röntgentechnik, Fürth, Germany; 2 Austria Aluguss

More information

OptiCon X-Line 3D. Combined 3D X-ray and Optical Inspection at Production Line Pace

OptiCon X-Line 3D. Combined 3D X-ray and Optical Inspection at Production Line Pace OptiCon X-Line 3D Combined 3D X-ray and Optical Inspection at Production Line Pace 1470 mm Automated X-Ray Inspection (AXOI) OptiCon X-Line 3D: AXI and AOI teamed up High-Speed X-Ray System for Maximum

More information

MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY

MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY MONITORING THE REPEATABILITY AND REPRODUCIBILTY OF A NATURAL GAS CALIBRATION FACILITY T.M. Kegel and W.R. Johansen Colorado Engineering Experiment Station, Inc. (CEESI) 54043 WCR 37, Nunn, CO, 80648 USA

More information

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography International Symposium on Digital Industrial Radiology and Computed Tomography - Poster 12 Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography Kim KIEKENS *, Ye TAN *, Jean-Pierre

More information