Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Size: px
Start display at page:

Download "Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation"

Transcription

1 Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field Kouichi Inagaki ICC / IHI Corporation 13 th WORLD CONFERENCE ON INVESTMENT CASTING Paper: T3 Copyright reserved: Neither the Japan Foundry Society, Inc. nor its officers accept legal responsibility for information, advice given or opinions expressed.

2 Application of Recent X-ray CT technology to Investment casting field K. Inagaki 1 Y. Saitou 2 H. Tohyama 3, H. Honda 3 1Materials Technology Department Aero-Engine & Space Operations IHI Corporation 2 Materials Department Corporate Research & Development IHI Corporation 3 Enginnering Department IHI castings Corporation Abstract X-ray computed tomography (CT) technology has been applied in medical field from early 1970s and in industrial field from 80s. Primary application in industrial field was for inspecting or observing the inner structure and defects. Recently, it has also been applied to acquire actual 3D CAD data and for dimensional measurement (1). This paper describes the utilization of actual 3D CAD data and the application of dimensional measurement for investment casting. 1. Introduction These days, X-ray CT has been applied for dimensional metrology. X-ray CT is the only method able to measure and acquire not only outer structure but also inner structure without need to destroy it. The dimensional metrology in investment casting field, especially for comparably absorbing materials of X-ray such as Ti and Ni alloy castings and for thicker casting parts, calls for higher penetrating power and higher resolution CT system. Recent development achieved to produce higher penetrating power and higher resolution X-ray CT system. This system will expand the utilization for investment casting field. For example, utilization for casting simulation, shape comparison (between CAD model and actual 3D volume data by X-ray CT), dimension measurement and so on are assumed. In this paper, utilization for casting simulation and dimension measurement are discussed. Casting simulation is widely used to establish a manufacturing process of casting. In the simulation,castingmoldis generalyuseduniformcadmodel.so,themodelcan t realize the actual casting mold (e.g. some voids and non-uniform thickness). The difference between uniform and actual (non-uniform) model would affect partially the accuracy of the simulation. To propose the improvement of casting simulation accuracy, actual CAD model is acquired by X-ray CT and applied for the simulation, since X-ray CT system can produce CAD model of actual casting mold which has outer structure, inner structure, inner voids and non-uniform thickness. In dimension measurement of wall thickness in investment casting, for example hollow turbine blade, UT is generally used. However, UT is affected by human factor and secondary crystallographic orientation. This paper proposes to use X-ray CT for wall thickness measurement. Since X-ray CT data can be acquired automatically and its data is digital, CT would be less affected by human factor than UT. And CT scan is generally not affected by secondary crystallographic orientation.

3 2. X-ray CT system The X-ray system used in this study consists of X-ray source, rotating table, X-ray detector, reconstruction unit and measurement unit. The X-ray source has higher power 450kV acceleration voltage. Two types of detectors are used. One is curved line detector array (CLDA) consisting of 1D array pixels. The other is flat panel detectors consisting of 2D array of pixels. The detector is selected according to the purpose of the study. Since the flat panel size is about 400mmx400mm area, large area can be detected at once. Since the object for the study of casting simulation is large, flat panel detector is used. CLDA is consisted with solid elements which can detect higher energy X-ray photons effectively and it realizes higher measurement accuracy in higher energy. For the study of dimensional measurement, higher energy X-ray is needed, therefore CLDA is used. However, CLDA is line array detector so inspection area is restricted compared with flat panel detector. In the scanning of this study, the X-ray source and the detector are fixed, while the object is put on the turntable and rotated 360deg between X-ray source and the detector or more X-ray perspective images of different angles are obtained by detector. Prior to scanning, inspection parameters such as acceleration voltage, current, projection number and so on, are fixed. After inspection, acquired perspective images are reconstructed into 2D cross-sectional image or 3D volume data. There are also parameters to be fixed in the reconstruction process such as resolution level and so on. After the reconstruction, the 2D cross-sectional image or 3D volume data is displayed on the PC monitor by the specific 3D software. To fix scanning and/or reconstruction parameters which affect dimension accuracy and spatial resolution, standard cylinder test piece for dimension accuracy and slit test piece for spatial resolution are scanned prior to part scanning. Fig.1 X-Ray CT data (left: Cylinder test piece, right: slit test piece) 3. As application for quantitative evaluation, improvement of Casting simulation accuracy by actual 3D volume image acquired by X-Ray CT In conventional casting simulation, 3D CAD model of uniform mold is used. However, actual casting mold is not uniform: some voids are included and shell thickness is not constant. If this difference can be compensated, casting simulation accuracy will be improved. In this paper, to compensate for this difference, the actual casting mold model

4 of 3D volume data by X-ray CT is applied for casting simulation. The evaluation object is the cast mold for simple test piece (for example, tensile or HCF test piece. Fig.2 left). After scanning and reconstruction of the test piece, 3D volume data which includes inner voids and presents non-uniform shell (figured in Fig.2 right) was acquired. Fig.2 Figure of casting mold (Left) and actual casting mold model acquired by CT (Right) 10M Acquired CT volume STL format 360MB 6M CAD B Mesh data Fig.3 Sample result of casting mold (2) Since the data includes inner voids and presents non-uniform shell, the data volume was 36GB. The data was too large to be imported to casting simulation software. The data needed to be reduced its data volume. And, since the data of the actual casting mold model of 3D volume data by X-ray CT was STL format, the data needed to be translated into mesh data.

5 Point 1 Point 1 Point 4 Point 2 Point 4 Point 2 Point 3 Point 3 Left: Simulation from CT volume. Right: Simulation from CAD data Fig. 4 Comparison with simulation from CT volume and CAD data These days, reverse engineering software has achieved remarkable development and some software are released. For this study, most appropriate reverse engineering software Simpleware was searched and selected. This software can translate 3D volume data by X-ray CT (e.g. STL format, polygon format and so on) into 3D mesh data and reduce data volume. Fig.3 shows the result of translations conducted by Japanese agent JSOL Corporation. The acquired STL data of cast mold was translated into PATRAN format mesh model by Simpleware.Andthen,themeshmodelwas importedtocastingsimulationsoftware. Fig.4 left shows the simulation result of casting mold model acquired by 3D volume data by X-ray CT. Fig.4 right shows the simulation result of uniform CAD model. Fig.4 shows that shrinkage positions anticipated by X-ray CT data and uniform CAD model is consistent each other, however, differences are obtained in shrinkage occurrence risk and cooling rate. This result indicates that using actual model improve the casting simulation accuracy, however actual verification is needed. 4. The utilization of X-Ray CT for the dimensional measurement using comparative evaluation method To apply CT for dimensional measurement, there are still some problems (e.g. accuracy, reliability) to be solved. One of problems is how to define the correct boundaries of a part

6 in 3D volume data acquired by CT. This paper proposes to use comparative evaluation method to solve the problem for the specific parts. 4.1 Test piece Five test pieces assumed Ni hollow turbine blade of single crystal were manufactured. Each test piece had eight different wall thickness areas to be measured. Since comparative evaluation was applied in this study, No1 (Fig.5) test piece was fixed as reference standard. No3, No4 and No5 test pieces had same shape as No1 but the wall thicknesses were different from each other. Detail thickness differences are listed on Table1. The differences are nominal value. Actual dimension and its difference were measured by CMM. No2 test piece had the same shape and wall thickness as No1 but its secondary crystallographic orientation was different direction from No1, No3, No4 and No5 had same secondary crystallographic orientation. Fig.5 Test piece simulated hollow turbine blade No.1 RV. No.2 Same as RV. Table1. Wall thicknesses Wall thickness No.3 Wall thickness for each area is RV mm. No.4 Wall thickness for each area is RV mm. No.5 Wall thickness for each area is RV mm. Recommend Secondary crystallographic orientation is different from others. RV: Reference value 4.2 CT data Fig.5 shows the 2D cross-sectional image of No1 standard test piece. The 2D image is the distribution of gray value which expresses the X-ray attenuation. Fig.7 shows the gray value profile on the a-b line written in Fig.6. As Fig. shows, the boundary between the air and the object changes with a gradient. In this study, the boundary was defined as center of the object and the air gray value (Iso-50%) in the histogram plotting the number of voxels versus the gray value (See Fig.8). 4.3 Measurement The measurement accuracy was calibrated by the standard cylinder test piece and the slit test piece. But non-symmetric shape of the object and some CT noise affected the measurement accuracy. So, the error was normalized by the No1 standard test piece.

7 Measurement positions of wall thickness are illustrated infig.6. Table2 shows the deviation of the wall thickness measured in CT data from CMM. In this study, dimensionalacuracyachieved±0.03mm or less. This result showed CT measurement accuracy is about same as that of ultrasonic inspection. Maximum deviation for No2 test piece which had different secondary crystallographic orientation from No1 was less than ±0.03mm. In the measurement of No2 test piece, crystal orientation correction was not applied. This result indicated that unlike ultrasonic inspection CT scanning was able to measure the dimension without being affected by crystal orientation. area-c area-d a area-b area-f area-a area-e b area-g area-h Measurement position Fig.6 CT result of the simulated hollow turbine blade test piece b a Fig. 7 Gray value profile of the line in Fig.4 Material Iso-50% Background Fig. 8 Histogram plotting the number of voxels versus the gray value (No.1 Sample)

8 Table2. Measurement result of deviation from CMM result Unit:mm area No.1 *1 No.2 *2 No.3 No.4 No.5 A B C D E F G H *1: No.1: RV *2: No.2: Secondary crystallographic orientation is different from others. 5. Summary (1) Simulation results from uniform CAD model and from 3D volume data by X-ray CT showed some differences. This result indicates that using actual model improve the casting simulation accuracy. (2) Dimensional measurement by CT indicated the enough accuracy to be replaced with ultrasonic measurement. References (1) J.P. Kruth et al, 2011, Computed tomography for dimensional metrology, Manufacturing Technology 60 p (2) InformationonSimpleware wi lbeadiversionarticlefromawebsiteofjapan agency corporation JSOL (

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control Oliver BRUNKE 1,

More information

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control 6 th International Congress of Metrology, 06003 (203) DOI: 0.05/ metrology/20306003 C Owned by the authors, published by EDP Sciences, 203 A new Concept for High-Speed atline and inlinect for up to 00%

More information

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis Oliver Brunke 1, Ferdinand Hansen 2, Ingo Stuke 3, Friedrich

More information

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system ECNDT 2014 Prague October 6-10, 2014 Dr. Eberhard Neuser Dr. Alexander Suppes Imagination

More information

The new generation of industrial computed tomography. The Desktop CT exact S

The new generation of industrial computed tomography. The Desktop CT exact S The new generation of industrial computed tomography The Desktop CT S Volume scanning technology Innovation with a family tradition Founded in 1968, the family-owned, WEN- ZEL Metrology Group is one of

More information

New Approach in Non- Contact 3D Free Form Scanning

New Approach in Non- Contact 3D Free Form Scanning New Approach in Non- Contact 3D Free Form Scanning Contents Abstract Industry Trends The solution A smart laser scanning system Implementation of the laser scanning probe in parts inspection Conclusion

More information

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY David K. Lehmann 1, Kathleen Brockdorf 1 and Dirk Neuber 2 1 phoenix x-ray Systems + Services Inc. St. Petersburg, FL, USA 2 phoenix x-ray Systems + Services

More information

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications Frank Welkenhuyzen 1, Bart Boeckmans 1, Ye Tan 1,2, Kim Kiekens 1,2, Wim Dewulf 1,2,

More information

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY

INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY INDUSTRIAL SYSTEM DEVELOPMENT FOR VOLUMETRIC INTEGRITY VERIFICATION AND ANALYSIS M. L. Hsiao and J. W. Eberhard CR&D General Electric Company Schenectady, NY 12301 J. B. Ross Aircraft Engine - QTC General

More information

CT in Dimensional Metrology, Engineering and Manufacture

CT in Dimensional Metrology, Engineering and Manufacture CT in Production Quality Control - Leuven, June 4, 2013 CT in Dimensional Metrology, Engineering and Manufacture Prof. Dr. Ir. Jean-Pierre KRUTH Katholieke Universiteit Leuven (K.U.Leuven) Mechanical Engineering

More information

Optiv CT160 Accurate measurement for every detail. Computed Tomography System

Optiv CT160 Accurate measurement for every detail. Computed Tomography System Optiv CT160 Accurate measurement for every detail Computed Tomography System Computed Tomography CT Technology. New prospects for metrology. Computed tomography (CT), a technology with unique advantages,

More information

Recognition and Measurement of Small Defects in ICT Testing

Recognition and Measurement of Small Defects in ICT Testing 19 th World Conference on Non-Destructive Testing 2016 Recognition and Measurement of Small Defects in ICT Testing Guo ZHIMIN, Ni PEIJUN, Zhang WEIGUO, Qi ZICHENG Inner Mongolia Metallic Materials Research

More information

Efficient 3D Crease Point Extraction from 2D Crease Pixels of Sinogram

Efficient 3D Crease Point Extraction from 2D Crease Pixels of Sinogram Efficient 3D Crease Point Extraction from 2D Crease Pixels of Sinogram Ryo Jinnouchi 1, Yutaka Ohtake 1, Hiromasa Suzuki 1, Yukie Nagai 1 1 The University of Tokyo, Japan, e-mail: {jinnouchi, yu-ohtake,

More information

Industrial Computed Tomography

Industrial Computed Tomography Industrial Computed Tomography YXLON International YXLON. The reason why 1 CT - applications YXLON. The reason why 2 CT - principles Computed Tomography (Line Detector) YXLON. The reason why 3 CT - principles

More information

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT

Novel evaluation method of low contrast resolution performance of dimensional X-ray CT More Info at Open Access Database www.ndt.net/?id=18754 Novel evaluation method of low contrast resolution performance of dimensional X-ray CT Makoto Abe 1, Hiroyuki Fujimoto 1, Osamu Sato 1, Kazuya Matsuzaki

More information

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography International Symposium on Digital Industrial Radiology and Computed Tomography - Poster 12 Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography Kim KIEKENS *, Ye TAN *, Jean-Pierre

More information

Roger Wende Acknowledgements: Lu McCarty, Johannes Fieres, Christof Reinhart. Volume Graphics Inc. Charlotte, NC USA Volume Graphics

Roger Wende Acknowledgements: Lu McCarty, Johannes Fieres, Christof Reinhart. Volume Graphics Inc. Charlotte, NC USA Volume Graphics Roger Wende Acknowledgements: Lu McCarty, Johannes Fieres, Christof Reinhart Volume Graphics Inc. Charlotte, NC USA 2018 Volume Graphics VGSTUDIO MAX Modules Inline Fiber Orientation Analysis Nominal/Actual

More information

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications 4th International Symposium on NDT in Aerospace 2012 - Tu.3.A.1 Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications Malte KURFISS 1, Gerd STRECKENBACH 2 1 YXLON International

More information

3D Computed Tomography (CT) Its Application to Aerospace Industry

3D Computed Tomography (CT) Its Application to Aerospace Industry 3D Computed Tomography (CT) Its Application to Aerospace Industry C. Muralidhar, M. P. Subramanian, V. Ravi Shankar and G. Chandrasekhar Directorate of Non Destructive Evaluation, Defence Research & Development

More information

Advanced automated High Speed Computed Tomography for production process control. DGZfP 2011, Bremen

Advanced automated High Speed Computed Tomography for production process control. DGZfP 2011, Bremen DGZfP-Jahrestagung 2011 - Mo.3.B.3 Advanced automated High Speed Computed Tomography for production process control DGZfP 2011, Bremen Dr. Ingo Stuke* and Dr. Oliver Brunke** GE Sensing & Inspection Technologies

More information

US foundry Bradken implements optical measuring technology

US foundry Bradken implements optical measuring technology Application Note US foundry Bradken implements optical measuring technology Location / country: Tacoma / Washington, USA GOM systems: ATOS Triple Scan, TRITOP GOM software: ATOS Professional Sector: Power

More information

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography Marc Kachelrieß, a Katia Sourbelle, and Willi A. Kalender Institute of Medical Physics, University of

More information

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques

Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image Processing Techniques SINCE2013 Singapore International NDT Conference & Exhibition 2013, 19-20 July 2013 Non-Destructive Failure Analysis and Measurement for Molded Devices and Complex Assemblies with X-ray CT and 3D Image

More information

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

Combining Analytical and Monte Carlo Modelling for Industrial Radiology 19 th World Conference on Non-Destructive Testing 2016 Combining Analytical and Monte Carlo Modelling for Industrial Radiology Carsten BELLON, Gerd-Rüdiger JAENISCH, Andreas DERESCH BAM Bundesanstalt für

More information

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM M. Simon, C. Sauerwein, I. Tiseanu, S. Burdairon Hans Wälischmiller GmbH Klingleweg 8, D-88709 Meersburg, Germany e-mail: ms@hwm.com ABSTRACT A new flexible

More information

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components J. Luebbehuesen GE Sensing & Inspection Technologies GmbH, phoenix x-ray, Niels-Bohr-Str.

More information

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Developments in Dimensional Metrology in X-ray Computed Tomography at NPL Wenjuan Sun and Stephen Brown 10 th May 2016 1 Possible factors influencing XCT measurements Components Influencing variables Possible

More information

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling nd International Symposium on NDT in Aerospace - We..A. Comparison of Probing Error in Dimensional Measurement by Means of D Computed Tomography with Circular and Helical Sampling Jochen HILLER, Stefan

More information

Convergent Modeling and Reverse Engineering

Convergent Modeling and Reverse Engineering Convergent Modeling and Reverse Engineering 25 October 2017 Realize innovation. Tod Parrella NX Design Product Management Product Engineering Solutions tod.parrella@siemens.com Realize innovation. Siemens

More information

Coordinate Measuring Machines with Computed Tomography

Coordinate Measuring Machines with Computed Tomography Always a Step Ahead with Quality Coordinate Measuring Machines with Computed Tomography Multisensor Coordinate Measuring Machines with Computed Tomography Computed Tomography in Coordinate Measuring Machines

More information

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ; HOW INDUSTRIAL COMPUTER TOMOGRAPHY ACCELERATES PRODUCT DEVELOPMENT IN THE LIGHT METAL CASTING AND INJECTION MOULDING INDUSTRY. Christof REINHART 1, Christoph POLIWODA 1, Thomas GÜNTHER 1 1 Volume Graphics

More information

MODERN DIMENSIONAL MEASURING TECHNIQUES BASED ON OPTICAL PRINCIPLES

MODERN DIMENSIONAL MEASURING TECHNIQUES BASED ON OPTICAL PRINCIPLES MODERN DIMENSIONAL MEASURING TECHNIQUES BASED ON OPTICAL PRINCIPLES J. Reichweger 1, J. Enzendorfer 1 and E. Müller 2 1 Steyr Daimler Puch Engineering Center Steyr GmbH Schönauerstrasse 5, A-4400 Steyr,

More information

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape Tasuku Ito 1, Yutaka Ohtake 1, Yukie Nagai 2, Hiromasa Suzuki 1 More info about this article: http://www.ndt.net/?id=23662

More information

MCT225 HA Metrology CT

MCT225 HA Metrology CT MCT225 HA Metrology CT Absolute accuracy for inside metrology nikon metrology I vision beyond precision Today, manufacturers are seeking to reduce time-to-market, despite a greater variety of products

More information

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography Natalia Grozmani 1, Andrea Buratti 1, Robert H. Schmitt 1 More info about this article:

More information

Application of NDT & Metrological Methods for the Characterization of Starting Nozzle of an Aero Engine

Application of NDT & Metrological Methods for the Characterization of Starting Nozzle of an Aero Engine Application of NDT & Metrological Methods for the Characterization of Starting Nozzle of an Aero Engine Suneel Kumar 1, M.R.Vijaya Lakshmi, A.K. Mondal, B.V. Ravi Dutta, Sreelal Sreedhar Abstract Gas Turbine

More information

Notice that the height of each rectangle is and the width of each rectangle is.

Notice that the height of each rectangle is and the width of each rectangle is. Math 1410 Worksheet #40: Section 6.3 Name: In some cases, computing the volume of a solid of revolution with cross-sections can be difficult or even impossible. Is there another way to compute volumes

More information

DUE to beam polychromacity in CT and the energy dependence

DUE to beam polychromacity in CT and the energy dependence 1 Empirical Water Precorrection for Cone-Beam Computed Tomography Katia Sourbelle, Marc Kachelrieß, Member, IEEE, and Willi A. Kalender Abstract We propose an algorithm to correct for the cupping artifact

More information

Medical Image Processing: Image Reconstruction and 3D Renderings

Medical Image Processing: Image Reconstruction and 3D Renderings Medical Image Processing: Image Reconstruction and 3D Renderings 김보형 서울대학교컴퓨터공학부 Computer Graphics and Image Processing Lab. 2011. 3. 23 1 Computer Graphics & Image Processing Computer Graphics : Create,

More information

Development of Reverse Engineering System for Machine Engineering Using 3D Bit-map Data. Tatsuro Yashiki* and Tarou Takagi*

Development of Reverse Engineering System for Machine Engineering Using 3D Bit-map Data. Tatsuro Yashiki* and Tarou Takagi* Development of Reverse Engineering System for Machine Engineering Using 3D Bit-map Data Tatsuro Yashiki* and Tarou Takagi* *Power & Industrial Systems R&D Laboratory, Hitachi, Ltd. Abstract In this paper,

More information

See Beyond the Surface. CT Scanning Redefining Industrial Metrology

See Beyond the Surface. CT Scanning Redefining Industrial Metrology See Beyond the Surface CT Scanning Redefining Industrial Metrology Table of Contents Table of Contents 1. What is Computed Tomography (CT) Scanning? 2. How CT Scanning Works 3. Advantages of CT Scanning

More information

SANGAM PROJECT BROCHURE:

SANGAM PROJECT BROCHURE: SANGAM PROJECT BROCHURE: Real-Time 3D Object Reconstruction using Kinect By: Sudharshan Suresh Narendar Sriram Senthil Hariharan Anjana Gayathri Spider R & D Introduction In a year where astronauts in

More information

Limited view X-ray CT for dimensional analysis

Limited view X-ray CT for dimensional analysis Limited view X-ray CT for dimensional analysis G. A. JONES ( GLENN.JONES@IMPERIAL.AC.UK ) P. HUTHWAITE ( P.HUTHWAITE@IMPERIAL.AC.UK ) NON-DESTRUCTIVE EVALUATION GROUP 1 Outline of talk Industrial X-ray

More information

CRONOS 3D DIMENSIONAL CERTIFICATION

CRONOS 3D DIMENSIONAL CERTIFICATION CRONOS 3D DIMENSIONAL CERTIFICATION This dimensional certification is structured as follow: 1. 2. 3. 4. 5. Test description Dimensional report basic workflow Dimensional report, acquisition field 18mm

More information

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS

THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS THREE DIMENSIONAL INDUSTRIAL METROLOGY USING X-RAY COMPUTED TOMOGRAPHY ON COMPOSITE MATERIALS A. Campos a*, A. Zorrilla a, F. Lasagni a a Materials & Processes dept., Center for Advanced Aerospace Technologies

More information

Radiographic Simulator artist: Version 2

Radiographic Simulator artist: Version 2 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Radiographic Simulator artist: Version 2 Carsten Bellon 1, Andreas Deresch 1, Christian Gollwitzer 1, Gerd-Rüdiger

More information

Dedicated Software Algorithms for 3D Clouds of Points

Dedicated Software Algorithms for 3D Clouds of Points Dedicated Software Algorithms for 3D Clouds of Points Introduction AQSENSE develops and commercializes 3D image acquisition and processing technologies that allow high speed in-line 100% production inspection,

More information

Enhanced material contrast by dual-energy microct imaging

Enhanced material contrast by dual-energy microct imaging Enhanced material contrast by dual-energy microct imaging Method note Page 1 of 12 2 Method note: Dual-energy microct analysis 1. Introduction 1.1. The basis for dual energy imaging Micro-computed tomography

More information

Industrial Computed Tomography Innovations

Industrial Computed Tomography Innovations GE Inspection Technologies Industrial Computed Tomography Innovations Premium performance for premium quality and speed. gemeasurement.com/ct Premium CT technologies. Faster than ever before. Every industrial

More information

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING

TOLERANCE ANALYSIS OF THIN-WALL CFRP STRUCTURAL ELEMENTS USING TOMOGRAPHIC IMAGING Proceedings of the 6th International Conference on Mechanics and Materials in Design, Editors: J.F. Silva Gomes & S.A. Meguid, P.Delgada/Azores, 26-30 July 2015 PAPER REF: 5495 TOLERANCE ANALYSIS OF THIN-WALL

More information

DUAL energy X-ray radiography [1] can be used to separate

DUAL energy X-ray radiography [1] can be used to separate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy

More information

Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts

Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts Fracture Mechanics and Nondestructive Evaluation Modeling to Support Rapid Qualification of Additively Manufactured Parts ASTM Workshop on Mechanical Behavior of Additive Manufactured Components May 4,

More information

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection Mariusz Jedrychowski EN/MME-MM Introduction of new technique at CERN 12/12/2017

More information

Extracting Woven Yarns of Ceramic Matrix Composite Parts With X-ray CT Scanning

Extracting Woven Yarns of Ceramic Matrix Composite Parts With X-ray CT Scanning Extracting Woven Yarns of Ceramic Matrix Composite Parts With X-ray CT Scanning Yuta Yamauchi, Hiromasa Suzuki, Takashi Michikawa, Yutaka Ohtake, Kouichi Inagaki, Hiroyuki Hishida, Takeshi Nakamura The

More information

MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM

MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM MULTI-MODALITY 3D VISUALIZATION OF HARD-ALPHA IN TITANIUM BILLETS UTILIZING CT X-RAY AND ULTRASONIC IMAGING Mano Bashyam and Vi Sub GE Aircraft Engines, Mail Drop Q45 1, Neumann Way Cincinnati, OH 45215

More information

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL

AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL AUTOMATED HIGH SPEED VOLUME COMPUTED TOMOGRAPHY FOR INLINE QUALITY CONTROL R. Hanke 1, A. Kugel 2, and P. Troup 2 1 Fraunhofer-Entwicklungszentrum für Röntgentechnik, Fürth, Germany; 2 Austria Aluguss

More information

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE

A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE A THREE-DIMENSIONAL PHASED ARRAY ULTRASONIC TESTING TECHNIQUE So KITAZAWA, Naoyuki KONO, Atsushi BABA and Yuji ADACHI HITACHI, Ltd., Japan Mitsuru ODAKURA HITACHI-GE Nuclear Energy, Ltd., Japan Introduction

More information

How does the ROI affect the thresholding?

How does the ROI affect the thresholding? How does the ROI affect the thresholding? Micro-computed tomography can be applied for the visualization of the inner structure of a material or biological tissue in a non-destructive manner. Besides visualization,

More information

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction In this lab exercise, you will investigate the linearity of the DeskCAT scanner by making measurements

More information

COMPUTED TOMOGRAPHY ON ELECTRONIC COMPONENTS BETTER WAYS TO DO FAILURE ANALYSIS PLUS 4D CT THE NEW FRONTIER

COMPUTED TOMOGRAPHY ON ELECTRONIC COMPONENTS BETTER WAYS TO DO FAILURE ANALYSIS PLUS 4D CT THE NEW FRONTIER COMPUTED TOMOGRAPHY ON ELECTRONIC COMPONENTS BETTER WAYS TO DO FAILURE ANALYSIS PLUS 4D CT THE NEW FRONTIER Wesley F. Wren North Star Imaging Rogers, MN, USA wwren@4nsi.com or wrenwesley@hotmail.com ABSTRACT

More information

On the impact of probing form error on form measurement in Computed Tomography

On the impact of probing form error on form measurement in Computed Tomography On the impact of probing form error on form measurement in Computed Tomography Jan Lasson Andreasen 1, Filippo Montanari 2, Leonardo De Chiffre 2 More info about this article: http://www.ndt.net/?id=23729

More information

New Method for Master Pattern Tool Correction Based on Computed Tomography Data and Intelligent Reverse Engineering

New Method for Master Pattern Tool Correction Based on Computed Tomography Data and Intelligent Reverse Engineering New Method for Master Pattern Tool Correction Based on Computed Tomography Data and Intelligent Reverse Engineering Dominik Schmid 1, Jochen Merz 1, Jochen Hiller 2 1 Carl Zeiss Holometric Technologies

More information

Frequency-based method to optimize the number of projections for industrial computed tomography

Frequency-based method to optimize the number of projections for industrial computed tomography More Info at Open Access Database www.ndt.net/?id=18739 Frequency-based method to optimize the number of projections for industrial computed tomography Andrea Buratti 1, Soufian Ben Achour 1, Christopher

More information

CT Systems and their standards

CT Systems and their standards CT Systems and their standards Stephen Brown Engineering Measurement 11 th April 2012 Industrial X-ray computed tomography: The future of co-ordinate metrology? Burleigh Court, Loughborough University

More information

CIVA Computed Tomography Modeling

CIVA Computed Tomography Modeling CIVA Computed Tomography Modeling R. FERNANDEZ, EXTENDE, France S. LEGOUPIL, M. COSTIN, D. TISSEUR, A. LEVEQUE, CEA-LIST, France page 1 Summary Context From CIVA RT to CIVA CT Reconstruction Methods Applications

More information

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography Characterization of microshells experimented on Laser Megajoule using X-Ray tomography More info about this article: http://www.ndt.net/?id=20881 Alexandre Choux, Lise Barnouin, Ludovic Reverdy, Marc Theobald

More information

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and

More information

Pipe Inspection with Digital Radiography

Pipe Inspection with Digital Radiography NDT INNOVATIVE COMPACT RUGGED Portable Digital Radiography Systems Pipe Inspection with Digital Radiography Railways www. NOVO-DR.com Pipe Inspection with Digital Radiography Digital Radiography or DR

More information

MEDICAL IMAGING 2nd Part Computed Tomography

MEDICAL IMAGING 2nd Part Computed Tomography MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional

More information

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS 23 RD INTERNATIONAL SYMPOSIUM ON BALLISTICS TARRAGONA, SPAIN 16-20 APRIL 2007 HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS P. Helberg 1,

More information

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Artifact Mitigation in High Energy CT via Monte Carlo Simulation PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident

More information

Comparision of contact and contactless measuring methods for form evaluation

Comparision of contact and contactless measuring methods for form evaluation Available online at www.sciencedirect.com Procedia Engineering 48 (2012 ) 273 279 MMaMS 2012 Comparision of contact and contactless measuring methods for form evaluation Peter Ka uch a, Miroslav Dovica

More information

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners

Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners Application of 450 kv Computed Tomography to Engine Blocks with Steel Liners Charles R. Smith, Kevin Holt BIR, Inc. Uwe Bischoff, Bernd Georgi, Ferdinand Hansen, Frank Jeltsch Volkswagen Commercial Vehicles

More information

The new generation of industrial computed tomography. The CT workstation exact M

The new generation of industrial computed tomography. The CT workstation exact M The new generation of industrial computed tomography The CT workstation M Volume scanning technology Innovation with a family tradition Founded in 1968, the family-owned, WEN- ZEL Metrology Group is one

More information

AM INSPECTION / NDT: IS XCT THE SOLUTION?

AM INSPECTION / NDT: IS XCT THE SOLUTION? AM INSPECTION / NDT: IS XCT THE SOLUTION? Dr. Nick Brierley Principal Research Engineer Metrology & NDT Group nick.brierley@the-mtc.org April 2018 OUTLINE Challenges of AM post-build inspection XCT for

More information

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Bernd Schweizer, Andreas Goedicke Philips Technology Research Laboratories, Aachen, Germany bernd.schweizer@philips.com Abstract.

More information

CT INSPECTION OF CASTINGS WITH IMPROVED CALIBRATION

CT INSPECTION OF CASTINGS WITH IMPROVED CALIBRATION Copyright 2004 SAE International O5M-498 CT INSPECTION OF CASTINGS WITH IMPROVED CALIBRATION Charles R. Smith, Kyung S. Han BIR Inc Uwe Bischoff, Bernd Georgi, Ferdinand Hansen, Frank Jeltsch Volkswagen

More information

High Resolution Phased Array Imaging using the Total Focusing Method

High Resolution Phased Array Imaging using the Total Focusing Method High Resolution Phased Array Imaging using the Total Focusing Method S. Kierspel, Wolfram A. Karl Deutsch, Helge Rast, Philippe Benoist 1, Venkat A 2 KARL DEUTSCH Pruef- und Messgeraetebau GmbH + Co KG

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Advanced Image Reconstruction Methods for Photoacoustic Tomography Advanced Image Reconstruction Methods for Photoacoustic Tomography Mark A. Anastasio, Kun Wang, and Robert Schoonover Department of Biomedical Engineering Washington University in St. Louis 1 Outline Photoacoustic/thermoacoustic

More information

Example of 3D Injection Molding CAE Directly Connected with 3D CAD

Example of 3D Injection Molding CAE Directly Connected with 3D CAD 3D TIMON Example of 3D Injection Molding CAE Directly Connected with 3D CAD 1 Background Problem of Data Translation from 3D CAD to CAE 3D TIMON Difficulty to Generate mesh Automatically Topologically

More information

Implementation of Automated 3D Defect Detection for Low Signal-to Noise Features in NDE Data

Implementation of Automated 3D Defect Detection for Low Signal-to Noise Features in NDE Data Implementation of Automated 3D Defect Detection for Low Signal-to Noise Features in NDE Data R. Grandin and J. Gray Center for NDE, Iowa State University, 1915 Scholl Road, Ames, IA 50011 USA Abstract.

More information

UNIT 10: Basic Geometric Shapes

UNIT 10: Basic Geometric Shapes UNIT 10: Basic Geometric Shapes SOLIDCast allows you to create basic geometric shapes that can be part of a casting model. Some simple castings may be created entirely with this type of shape. In other

More information

High Resolution Phased Array Imaging using the Total Focusing Method

High Resolution Phased Array Imaging using the Total Focusing Method 19 th World Conference on Non-Destructive Testing 2016 High Resolution Phased Array Imaging using the Total Focusing Method Wolfram A. Karl DEUTSCH 1, Werner ROYE 1, Helge RAST 1, Philippe BENOIST 2 1

More information

XT H 225 Industrial X-ray and Computed Tomography

XT H 225 Industrial X-ray and Computed Tomography XT H 225 Industrial X-ray and Computed Tomography nikon metrology I vision beyond precision Get the inside picture of complex industrial parts, by literally looking into the internal structure. Then use

More information

Separation of CT Nominal-Actual Comparisons for Compensation of Plastic Injection Molds

Separation of CT Nominal-Actual Comparisons for Compensation of Plastic Injection Molds Separation of CT Nominal-Actual Comparisons for Compensation of Plastic Injection Molds Robert Schmitt 1, Christopher Isenberg 1 1 WZL of RWTH Aachen University, Steinbachstr. 19, 52074 Aachen, Germany,

More information

FURNACE COILS INSPECTION SMART PIG TO INSPECT COILS ON PROCESS FURNACE

FURNACE COILS INSPECTION SMART PIG TO INSPECT COILS ON PROCESS FURNACE SMART PIG TO INSPECT COILS ON PROCESS FURNACE INTELLIGENT PIG TECHNOLOGY UNLIKE THE TO GUIDED WAVES NOT ONLY ALLOWS INSPECT PIPE STRAIGHT BUT ALSO ELBOWS UP 1D AND CHANGES 180, WHICH IS VERY COMMON IN

More information

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

More information

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Multi-spectral (W, Mo, Cu, and Ag) XCT measurements Marko Katić 1, Damir Markučič 1, Gorana Baršić 1 Faculty of mechanical engineering and naval architecture, Ivana Lucica 5, Zagreb, Croatia, marko.katic@fsb.hr

More information

Digital Volume Correlation for Materials Characterization

Digital Volume Correlation for Materials Characterization 19 th World Conference on Non-Destructive Testing 2016 Digital Volume Correlation for Materials Characterization Enrico QUINTANA, Phillip REU, Edward JIMENEZ, Kyle THOMPSON, Sharlotte KRAMER Sandia National

More information

L1 - Introduction. Contents. Introduction of CAD/CAM system Components of CAD/CAM systems Basic concepts of graphics programming

L1 - Introduction. Contents. Introduction of CAD/CAM system Components of CAD/CAM systems Basic concepts of graphics programming L1 - Introduction Contents Introduction of CAD/CAM system Components of CAD/CAM systems Basic concepts of graphics programming 1 Definitions Computer-Aided Design (CAD) The technology concerned with the

More information

Development of an automated bond verification system for advanced electronic packages

Development of an automated bond verification system for advanced electronic packages Development of an automated bond verification system for advanced electronic packages Michel Darboux, Jean-Marc Dinten LETI (CEA - Technologies AvancSes) - DSYS/SCSI CENG, 17 rue des Martyrs F38054 Grenoble

More information

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY 79 LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY Alexander Sasov, SkyScan, Vluchtenburgstraat 3, Aartselaar B2630, Belgium, www.skyscan.be. ABSTRACT Using advanced X-ray technologies and X-ray scattering

More information

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Beam Attenuation Grid Based Scatter Correction Algorithm for More Info at Open Access Database

More information

Dr. Javier Santillan, San Carlos, CA

Dr. Javier Santillan, San Carlos, CA X-ray diffraction as a tool for automated residual st ress analysis & a non-synchrotron based nanofocus x-ray computed tomography technique for materials characterization and metrology Dr. Javier Santillan,

More information

NMR IMAGING OF SNOW. KEYWORD: NMR, three-dimensional imaging, snow structure, ice sphere, dodecane 1. INTRODUCTUION

NMR IMAGING OF SNOW. KEYWORD: NMR, three-dimensional imaging, snow structure, ice sphere, dodecane 1. INTRODUCTUION NMR IMAGING OF SNOW Toshihiro Ozeki* Ship Research Institute, Mitaka, Japan Akihiro Hachikubo Kitami Institute of Technology, Kitami, Japan Katsumi Kose Institute of Applied Physics, University of Tsukuba,

More information

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems More Info at Open Access Database www.ndt.net/?id=16704 Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems Michael BÖHNEL 1, Andreas GRUBER 2, Nils REIMS 1,

More information

Introduction. File preparation

Introduction. File preparation White Paper Design and printing guidelines Introduction A print job can be created in either of the following ways: NOTE: HP SmartStream 3D Build Manager supports STL and 3MF files. By using the HP SmartStream

More information

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT Multisensor Coordinate Measuring Machines ZEISS O-INSPECT Having all the necessary options for reliable measurements. ZEISS O-INSPECT // RELIABILITY MADE BY ZEISS 2 The O-INSPECT multisensor measuring

More information

Robot-based real-time ultrasonic tomography for industrial NDT applications

Robot-based real-time ultrasonic tomography for industrial NDT applications 1 Robot-based real-time ultrasonic tomography for industrial NDT applications Dr. Andrey Bulavinov I-Deal Technologies GmbH 2 Content I. Introduction of I-Deal Technologies GmbH I-Deal Spin-Off of Fraunhofer-IZFP

More information