1 Nuclear Instruments and Methods in Physics Research A 621 (2010) Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: Preliminary experimental results of a quasi-monolithic detector with DOI capability for a small animal PET Yong Hyun Chung a,b,n, Cheol-Ha Baek a,b, Seung-Jae Lee a,b, Key Jo Hong c, Ji Hoon Kang d, Yong Choi c a Department of Radiological Science, College of Health Science, Yonsei University, 234 Meaji, Heungup, Wonju, Kangwon-Do , Republic of Korea b Institute of Health Science, Yonsei University, Wonju , Republic of Korea c Department of Electric Engineering, Sogang University, Seoul , Republic of Korea d Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul , Republic of Korea article info Article history: Received 16 January 2010 Received in revised form 5 April 2010 Accepted 12 April 2010 Available online 20 April 2010 Keywords: PET Maximum likelihood position estimation Monolithic crystal Depth of interaction abstract In our previous work, the new detector module with depth of interaction (DOI) based on a quasimonolithic crystal array and maximum-likelihood position-estimation (MLPE) algorithm was designed and the methodology for 3D event positioning in the detector was established by using Monte Carlo simulation. The aim of this study was to evaluate the performance of our detector module experimentally. The detector module consisted of a 1D array of eight LYSO crystals of 20.0(X) 2.0(Y) 10.0(Z) mm 3, optically coupled to a Hamamatsu H7546B position sensitive photomultiplier tube (PSPMT). The PSPMT was read out using a resistive charge divider, which multiplexes 64 anodes into 8(X)+8(Y) channels. Gaussian-based MLPE methods have been implemented using experimentally measured detector response functions (DRFs). The results demonstrated that the detector module could identify the position of the gamma ray interaction inside the crystal in all three directions. The new DOI detector for a small animal PET was developed and verified experimentally with a view towards achieving high sensitivity as well as high and uniform radial resolution. & 2010 Elsevier B.V. All rights reserved. 1. Introduction The demand for a high performance positron emission tomography (PET) is motivated by the need to perform molecular imaging of small animal models. However, thick scintillation crystals for high sensitivity in PET scanners cause radial elongation or parallax errors. To correct these problems and to improve the resolution uniformity across the field of view (FOV), there has been a growing interest in the design of small animal PET with the depth-of-interaction (DOI) determination capability. Most of developed DOI detector modules used matrices of small scintillating crystals, but the detection efficiency in such designs is reduced by the dead space between crystal elements [1 9]. As an alternative, monolithic crystal detectors with statistical positioning algorithms have been proposed. These detectors use several cubic centimeters of scintillating material coupled on one or more sides to photo sensor. These techniques require look-up tables (LUTs) containing information on the light distribution of scintillation events in the crystal as a function of source position, which are generated through computer simulation or machine training corresponding to a specific angle of incidence. Our group has introduced a new DOI detector concept based on an array of quasi-monolithic crystals and multi-channel photosensors used with a maximum-likelihood position-estimation (MLPE) algorithm [10 12]. The main advantage of the quasimonolithic detector is that the dependence of the light response on an event location can be measured experimentally, because the crystal elements are separated from each other in the axial direction and are monolithic in the trans-axial direction. In our previous work, we evaluated the performances through DETECT2000 simulation and the results showed that the detector could determine the position of the gamma events inside the crystal with a resolution of 2.0 mm in all three dimensions. The purpose of this study is to develop the proposed detector module and to evaluate the performances of it experimentally. 2. Materials and Methods 2.1. Quasi-monolithic detector n Corresponding author at: Department of Radiological Science, College of Health Science, Yonsei University, 234 Meaji, Heungup, Wonju, Kangwon-Do , Republic of Korea. Tel.: ; fax: address: ychung@yonsei.ac.kr (Y. Hyun Chung). Quasi-monolithic detector module employs a volumetric slab configuration, rather than a matrix of pixelated crystal elements. The module consists of a 1D array of eight LYSO crystals with /$ - see front matter & 2010 Elsevier B.V. All rights reserved. doi: /j.nima
2 Y. Hyun Chung et al. / Nuclear Instruments and Methods in Physics Research A 621 (2010) (X) 2.0(Y) 10.0(Z) mm 3 size. The crystal elements are discrete in the Y direction and are monolithic in the X direction, as shown in Fig. 1. The mm 2 bottom surface of the crystal is polished and directly coupled to a position-sensitive PMT (PSPMT) or an array of silicon multipliers (SiPMs). The large sides are wrapped with Teflon reflector so that the crystals are separated from each other in the Y direction. To reduce the degradation of the resolution near the edge of the crystal, the short sides are painted with absorbent material [10]. All 64 channels of the PMT are acquired for each event. To compute the event positions in the Y direction, eight outputs on the same row are summed, and the eight summed signals along the Y direction are compared to each other. After determining the Y position of the event, the MLPE algorithm is employed to extract the X and Z positions using eight output signals in the selected monolithic crystal MLPE algorithm The MLPE method uses the likelihood between the detector response function (DRF) of each PMT channel and the event position. Because of the stochastic nature of signal formation in a Fig. 1. (a) Schematic diagram of a quasi-monolithic crystal module and (b) the simulated apparatus for training. detector, the probability of measuring a given set of PMT output signals M¼M 1, M 2, y, M 8 for a given event position x in the crystal is described by the probability distribution as Pr(M9x). Assuming that the noise process in the detector response follows a Gaussian distribution, the likelihood is given by Y N Pr M9x ¼! 1 pffiffiffiffiffiffi exp ðm i m i ðxþþ 2 s i ðxþ 2p 2s 2 i ðxþ where m i (x) is the mean and s i (x) is the standard deviation of the ith output of PMT as a function of event position. Performing the maximization with respect to log likelihood, the resulting approximation is X n lnpr M i 9x ¼ ðm i m i ðxþþ 2 2s 2 i ðxþ þ Xn lns i ðxþ The MLPE solution is achieved by minimizing the value between parenthesis in Eq. (2) Experimental setup for training DRFs of each crystal element were determined by experimental training. The single LYSO crystal of size 20.0(X) 2.0(Y) 10.0(Z) mm 3 was optically coupled to a Hamamatsu H7546B PSPMT. The PSPMT was read out using a resistive charge divider, which multiplexes 64 anodes into 8(X)+8(Y) channels. Fig. 2 is a diagram of the experimental apparatus employed. During the experimental training, only one crystal element was coupled to PSPMT to generate gamma events at any location. Fig. 3 shows the DRF training system consisting of a collimated source, motorized x z stage, LYSO crystal, PSPMT, signal processing electronics and data acquisition system. F-18 source was housed in a 5 cm thick lead block and collimated into a pencil beam 1 mm in diameter. To characterize DRFs, data were acquired on 4 5 evenly spaced points with 2.0 mm spacing in the X and Z directions using a computer controlled stepper motor stage and collimated F-18 source. Then DRFs were generated using Gaussian fitting and bicubic spline interpolation.! ð1þ ð2þ Fig. 2. Block diagram of the circuitry of a detector module. Fig. 3. Detector and training system consist of collimated source, motorized x z stage, LYSO crystal, PSPMT, signal processing electronics and data acquisition board.
3 592 Y. Hyun Chung et al. / Nuclear Instruments and Methods in Physics Research A 621 (2010) Fig. 4. The point source image and global energy spectrum for one training position. Fig. 5. Energy spectra of eight X signals were plotted and the mean and standard deviation were extracted to generate LUT by Gaussian fitting Performance measurements After generating DRFs for a crystal element, the point source imaging was performed. To measure the intrinsic spatial resolution of the detector in the X direction, the image of the collimated source was obtained and the full-width at half-maximum of the profile was calculated. The measured DOI (Z-axis) positions were compared to the true positions of the collimated source. The misclassification rates, defined as the number of mis-assigned events in Z direction divided by the total number of events, were calculated for each source position. 3. Results Fig. 4 illustrates the point source image and global energy spectrum for one training position. Energy spectra of eight X signals were plotted and the mean and standard deviation were extracted to generate LUT by Gaussian fitting as shown in Fig. 5.
4 Y. Hyun Chung et al. / Nuclear Instruments and Methods in Physics Research A 621 (2010) Fig.6. The measured images of point sources located at nine different positions with 2.0 mm spacing. The numbers represent the positioning accuracies. Fig.6 represents the images of true source positions and the acquired images by MLPE algorithm. The positioning accuracies in the X and Z directions were calculated. The positioning accuracies for each source position were 91.7%, 97.8%, 99.8%, 95.5%, 98.6%, 99.7%, 96.8%, 91.3% and 99.9%, respectively, and the average is 96.8% in the X direction. The average misclassification rates in the DOI direction was 45% in the depth direction. 4. Discussion and conclusions A new DOI detector based on quasi-monolithic LYSO crystal and an MLPE algorithm was developed and tested. The source positions were accurately identified with 2.0 mm resolution in the X and Y directions, but the positioning accuracy in the depth direction was about 55%. Since the quasi-monolithic crystal elements were continuous in the X direction and separated in the Y direction, the spatial resolution in the Y direction was geometrically limited to 2.0 mm in this detector module. However, the spatial resolution can be improved by increasing the number of LUT sampling points and by reducing the physical crystal size in Y direction. The main advantage of the proposed detector module is that the LUTs needed for position estimates can be generated experimentally. For a monolithic crystal, generating a gamma event at a specific position is impossible, and for a pixelated crystal, the light distributions from events at different depths are indistinguishable. Also, the correction method for the nonuniform signals from PSPMT is not needed in this design because MLPE involves the use of LUTs to map from measured PSPMT signals to position estimates. Other advantages of this design include simple fabrication, higher packing fraction and high sensitivity. The positioning accuracy is affected by the light distribution in the crystal, which is largely varied by the surface conditions, especially for the DOI direction. In our previous simulation [10], the top surface of crystal was designed as diffuse reflecting material with a reflection coefficient (RC) of 0.5 and the position misclassification rate was calculated as 8% for the DOI direction. However, in the experiment, it is very hard to accurately wrap the crystal with specific RC value. Also, the wrapping material such as Teflon tape may introduce irregular dead spaces between crystals. Therefore, the optimization of the surface treatment of quasimonolithic crystal, a reflector material and an accurate surface treatment technique are required for further study to improve depth resolution. In this paper, PSPMT was considered as a photo-sensor in PET detector, but it can be replaced by an array of avalanche photodiodes (APDs) and SiPMs [8 9] in the future development due to their high quantum efficiency and positioning accuracy. In conclusion, using the quasi-monolithic detector, a small animal PET system with high sensitivity and uniform radial resolution might be realized. Acknowledgments This work was supported by a Korea Science and Engineering Foundation (KOSEF) grant funded by the Korea Government Ministry of Education, Science and Technology (MEST) ( ).
5 594 Y. Hyun Chung et al. / Nuclear Instruments and Methods in Physics Research A 621 (2010) References [1] A. Braem, et al., Nucl. Instr. and Meth. A 571 (2007) 419. [2] Y. Choi, et al., Nucl. Instr. and Meth. A 571 (2007) 669. [3] T. Hasegawa, et al., Phys. Med. Biol. 52 (2007) 213. [4] Y.H. Chung, et al., Phys. Med. Biol. 49 (2004) [5] A. Braem, et al., Nucl. Instr. and Meth. A 580 (2007) [6] Y. Shao, et al., Nucl. Instr. and Meth. A 580 (2007) 944. [7] Y. Yang, et al., Phys. Med. Biol. 51 (2006) [8] D. McElroy, et al., Nucl. Instr. and Meth. A 571 (2007) 106. [9] D.J. Herbert, et al., Nucl. Instr. and Meth. A 573 (2007) 84. [10] Y.H. Chung, et al., Nucl. Instr. and Meth. A 593 (2008) 588. [11] Y.H. Chung, et al., JKPS 54 (2009) 244. [12] S.-J. Lee, et al., JKPS 54 (2009) 2429.
ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A
Nuclear Instruments and Methods in Physics Research A 602 (2009) 477 483 Contents lists available at ScienceDirect Nuclear Instruments and Methods in Physics Research A journal homepage: www.elsevier.com/locate/nima
More information218 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 44, NO. 2, APRIL 1997
218 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 44, NO. 2, APRIL 1997 Compton Scatter and X-ray Crosstalk and the Use of Very Thin Intercrystal Septa in High-Resolution PET Detectors Craig S. Levin, Member,
More informationAn educational tool for demonstrating the TOF-PET technique
Nuclear Instruments and Methods in Physics Research A 471 (2001) 200 204 An educational tool for demonstrating the TOF-PET technique T.Bȧack a, *, J. Cederkȧall a, B. Cederwall a, A. Johnson a, A. Kerek
More informationDetermination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 50, NO. 3, JUNE 2003 405 Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging Edward J. Soares, Kevin W. Germino,
More informationA region segmentation based algorithm for building crystal position lookup table in scintillation detector
A region segmentation based algorithm for building crystal position lookup table in scintillation detector WANG Hai-Peng ( 王海鹏 ) 1,2,3 YUN Ming-Kai ( 贠明凯 ) 1,2 LIU Shuang-Quan ( 刘双全 ) 1,2 FAN Xin ( 樊馨
More informationMedical Imaging BMEN Spring 2016
Name Medical Imaging BMEN 420-501 Spring 2016 Homework #4 and Nuclear Medicine Notes All questions are from the introductory Powerpoint (based on Chapter 7) and text Medical Imaging Signals and Systems,
More informationGeant4 Studies for the HPD-PET scintillators
F. Ciocia, a A. Braem, b E. Chesi, b, a1 C. Joram, b L. Lagamba, a E. Nappi, a J. Séguinot, b I. Vilardi a and P. Weilhammer b a Physics Dept. and INFN Section of Bari, Via Orabona 4, Bari, Italy b CERN
More informationConstructing System Matrices for SPECT Simulations and Reconstructions
Constructing System Matrices for SPECT Simulations and Reconstructions Nirantha Balagopal April 28th, 2017 M.S. Report The University of Arizona College of Optical Sciences 1 Acknowledgement I would like
More informationSNIC Symposium, Stanford, California April The Hybrid Parallel Plates Gas Counter for Medical Imaging
The Hybrid Parallel Plates Gas Counter for Medical Imaging F. Anulli, G. Bencivenni, C. D Ambrosio, D. Domenici, G. Felici, F. Murtas Laboratori Nazionali di Frascati - INFN, Via E. Fermi 40, I-00044 Frascati,
More informationIntroduction to Positron Emission Tomography
Planar and SPECT Cameras Summary Introduction to Positron Emission Tomography, Ph.D. Nuclear Medicine Basic Science Lectures srbowen@uw.edu System components: Collimator Detector Electronics Collimator
More informationGeant4 Studies of the scintillator crystals for the axial HPD-PET concept
> FOR CONFERENCE-RELATED PAPERS, REPLACE THIS LINE WITH YOUR SESSION NUMBER, E.G., AB- (DOUBLE-CLICK HERE) < Geant4 Studies of the scintillator crystals for the axial HPD-PET concept F. Ciocia a, A. Braem
More informationWorkshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET
Workshop on Quantitative SPECT and PET Brain Studies 14-16 January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET Físico João Alfredo Borges, Me. Corrections in SPECT and PET SPECT and
More informationArtifact Mitigation in High Energy CT via Monte Carlo Simulation
PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident
More informationarxiv:physics/ v2 [physics.med-ph] 23 Nov 2005
arxiv:physics/0511065v2 [physics.med-ph] 23 Nov 2005 Experimental study of a liquid Xenon PET prototype module M.-L. Gallin-Martel 1, P. Martin, F. Mayet, J. Ballon, G. Barbier, C. Barnoux, J. Berger,
More informationImplementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system
Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system 3 rd October 2008 11 th Topical Seminar on Innovative Particle and Radiation
More informationCHAPTER 11 NUCLEAR MEDICINE IMAGING DEVICES
CHAPTER 11 M.A. LODGE, E.C. FREY Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University, Baltimore, Maryland, United States of America 11.1. INTRODUCTION Imaging
More informationDeliverable D10.2. WP10 JRA04 INDESYS Innovative solutions for nuclear physics detectors
MS116 Characterization of light production, propagation and collection for both organic and inorganic scintillators D10.2 R&D on new and existing scintillation materials: Report on the light production,
More informationCherenkov Radiation. Doctoral Thesis. Rok Dolenec. Supervisor: Prof. Dr. Samo Korpar
Doctoral Thesis Time-of-Flight Time-of-Flight Positron Positron Emission Emission Tomography Tomography Using Using Cherenkov Cherenkov Radiation Radiation Rok Dolenec Supervisor: Prof. Dr. Samo Korpar
More informationEffects of system geometry and other physical factors on photon sensitivity of high-resolution
Home Search Collections Journals About Contact us My IOPscience Effects of system geometry and other physical factors on photon sensitivity of high-resolution positron emission tomography This article
More informationWe are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,500 108,000 1.7 M Open access books available International authors and editors Downloads Our
More informationDevelopment of a high resolution animal PET with continuous crystals and SiPMs
Development of a high resolution animal PET with continuous crystals and SiPMs 1, John Barrio1, Jorge Cabello1,2, Ane Etxebeste1, Carlos Lacasta1, Josep F. Oliver1, Magdalena Rafecas1, Carles Solaz1, Vera
More information8/2/2017. Disclosure. Philips Healthcare (Cleveland, OH) provided the precommercial
8//0 AAPM0 Scientific Symposium: Emerging and New Generation PET: Instrumentation, Technology, Characteristics and Clinical Practice Aug Wednesday 0:4am :pm Solid State Digital Photon Counting PET/CT Instrumentation
More information8/1/2017. Current Technology: Energy Integrating Detectors. Principles, Pitfalls and Progress in Photon-Counting-Detector Technology.
Photon Counting Detectors and Their Applications in Medical Imaging Principles, Pitfalls and Progress in Photon-Counting-Detector Technology Taly Gilat Schmidt, PhD Associate Professor Department of Biomedical
More informationValidation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition
Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Bernd Schweizer, Andreas Goedicke Philips Technology Research Laboratories, Aachen, Germany bernd.schweizer@philips.com Abstract.
More informationSUBMITTED 15/08/2018 TO: IEEE TRPMS - SPEICIAL ISSUE PSMR2018-7TH CONFERENCE ON PET/MR AND SPECT/MR 1
SUBMITTED 15/08/2018 TO: IEEE TRPMS - SPEICIAL ISSUE PSMR2018-7TH CONFERENCE ON PET/MR AND SPECT/MR 1 A novel DOI Positioning Algorithm for Monolithic Scintillator Crystals in PET based on Gradient Tree
More informationIn-vivo dose verification for particle therapy
In-vivo dose verification for particle therapy D.R. Schaart, NCS Lustrum, 5-Oct-2012 HollandPTC 1 Protons vs. photons Photons Protons Dennis R. Schaart Delft University of Technology 2 Protons: the promise
More information18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa
18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa TOWARDS ESTABLISHMENT OF STANDARDIZED PRACTICE FOR ASSESSMENT OF SPATIAL RESOLUTION AND CONTRAST OF INTERNATIONAL
More informationMonte-Carlo simulation for scatter correction compensation studies in SPECT imaging using GATE software package
Nuclear Instruments and Methods in Physics Research A 569 (2006) 404 408 www.elsevier.com/locate/nima Monte-Carlo simulation for scatter correction compensation studies in SPECT imaging using GATE software
More informationOptical Modeling of Scintillation Detectors Using GATE
GATE Simulations of Preclinical and Clinical Scans in Emission Tomography, Transmission Tomography and Radiation Therapy Optical Modeling of Scintillation Detectors Using GATE Emilie Roncali Department
More informationModeling and Incorporation of System Response Functions in 3D Whole Body PET
Modeling and Incorporation of System Response Functions in 3D Whole Body PET Adam M. Alessio, Member IEEE, Paul E. Kinahan, Senior Member IEEE, and Thomas K. Lewellen, Senior Member IEEE University of
More informationFOOT de/dx detector: simulation report
FOOT de/dx detector: simulation report Matteo Bertazzoni, Maria Giuseppina Bisogni, Esther Ciarrocchi e Matteo Morrocchi February 16, 2017 1 Introduction The goals of the de/dx detector group are to determine
More informationA new PET prototype for proton therapy: comparison of data and Monte Carlo simulations
A new PET prototype for proton therapy: comparison of data and Monte Carlo simulations V. Rosso, G.Battistoni, N. Belcari, N. Camarlinghi, A. Ferrari, S. Ferretti, A. Kraan, A. Mairani, N. Marino, J. E.
More informationEffects of the difference in tube voltage of the CT scanner on. dose calculation
Effects of the difference in tube voltage of the CT scanner on dose calculation Dong Joo Rhee, Sung-woo Kim, Dong Hyeok Jeong Medical and Radiological Physics Laboratory, Dongnam Institute of Radiological
More informationProton dose calculation algorithms and configuration data
Proton dose calculation algorithms and configuration data Barbara Schaffner PTCOG 46 Educational workshop in Wanjie, 20. May 2007 VARIAN Medical Systems Agenda Broad beam algorithms Concept of pencil beam
More informationTHE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY
PAPER THE EFFECT OF SURFACE ROUGHNESS OF CSI(TL) MICRO-COLUMNS ON THE RESOLUTION OF THE X-RAY IMAGE; OPTICAL SIMULATION STUDY HYUNKI KIM, JUN HYUNG BAE, BO KYUNG CHA, HOSANG JEON, JONG YUL KIM, CHAN KYU
More informationMEDICAL IMAGING 2nd Part Computed Tomography
MEDICAL IMAGING 2nd Part Computed Tomography Introduction 2 In the last 30 years X-ray Computed Tomography development produced a great change in the role of diagnostic imaging in medicine. In convetional
More informationMonte-Carlo Modeling of Scintillator Crystal Performance for Stratified PET Detectors with DETECT2000
Monte-Carlo Modeling of Scintillator Crystal Performance for Stratified PET Detectors with DETECT2 Francois Cayouette, Member, IEEE, Christian Moisan, Nan Zhang, Member, IEEE and Christopher J. Thompson,
More informationContinuation Format Page
C.1 PET with submillimeter spatial resolution Figure 2 shows two views of the high resolution PET experimental setup used to acquire preliminary data [92]. The mechanics of the proposed system are similar
More informationLarge Plastic Scintillation Detectors for the Nuclear Materials Identification System
Large Plastic Scintillation Detectors for the Nuclear Materials Identification System J.S. Neal, J.T. Mihalczo, M. T. Hiatt, J. D. Edwards Oak Ridge National Laboratory P. O. Box 2008, Oak Ridge, Tennessee
More informationFast Timing and TOF in PET Medical Imaging
Fast Timing and TOF in PET Medical Imaging William W. Moses Lawrence Berkeley National Laboratory October 15, 2008 Outline: Time-of-Flight PET History Present Status Future This work was supported in part
More informationReview of PET Physics. Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA
Review of PET Physics Timothy Turkington, Ph.D. Radiology and Medical Physics Duke University Durham, North Carolina, USA Chart of Nuclides Z (protons) N (number of neutrons) Nuclear Data Evaluation Lab.
More informationREMOVAL OF THE EFFECT OF COMPTON SCATTERING IN 3-D WHOLE BODY POSITRON EMISSION TOMOGRAPHY BY MONTE CARLO
REMOVAL OF THE EFFECT OF COMPTON SCATTERING IN 3-D WHOLE BODY POSITRON EMISSION TOMOGRAPHY BY MONTE CARLO Abstract C.S. Levin, Y-C Tai, E.J. Hoffman, M. Dahlbom, T.H. Farquhar UCLA School of Medicine Division
More informationLimitations in the PHOTON Monte Carlo gamma transport code
Nuclear Instruments and Methods in Physics Research A 480 (2002) 729 733 Limitations in the PHOTON Monte Carlo gamma transport code I. Orion a, L. Wielopolski b, * a St. Luke s/roosevelt Hospital, Columbia
More informationSINGLE-PHOTON emission computed tomography
1458 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 59, NO. 4, AUGUST 2012 SPECT Imaging With Resolution Recovery Andrei V. Bronnikov Abstract Single-photon emission computed tomography (SPECT) is a method
More informationDesign and simulation of continuous scintillator with pixellated photodetector
University of Wollongong Research Online Faculty of Engineering - Papers (Archive) Faculty of Engineering and Information Sciences 2001 Design and simulation of continuous scintillator with pixellated
More informationTemperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System
Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Temperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System Shinji Ohyama, Masato Mukouyama Graduate School
More informationarxiv:physics/ v1 [physics.ins-det] 18 Dec 1998
Studies of 1 µm-thick silicon strip detector with analog VLSI readout arxiv:physics/981234v1 [physics.ins-det] 18 Dec 1998 T. Hotta a,1, M. Fujiwara a, T. Kinashi b, Y. Kuno c, M. Kuss a,2, T. Matsumura
More informationDETECT2000: An Improved Monte-Carlo Simulator for the Computer Aided Design of Photon Sensing Devices
DETECT2000: An Improved Monte-Carlo Simulator for the Computer Aided Design of Photon Sensing Devices François Cayouette 1,2, Denis Laurendeau 3 and Christian Moisan 3 1 Montreal Neurological Institute,
More informationApplication of MCNP Code in Shielding Design for Radioactive Sources
Application of MCNP Code in Shielding Design for Radioactive Sources Ibrahim A. Alrammah Abstract This paper presents three tasks: Task 1 explores: the detected number of as a function of polythene moderator
More informationIterative SPECT reconstruction with 3D detector response
Iterative SPECT reconstruction with 3D detector response Jeffrey A. Fessler and Anastasia Yendiki COMMUNICATIONS & SIGNAL PROCESSING LABORATORY Department of Electrical Engineering and Computer Science
More informationInterpolating Silicon Photomultipliers
Interpolating Silicon Photomultipliers Peter Fischer, Heidelberg University, Germany (Presenter) Claudio Piemonte, FBK, Italy We present the novel Interpolating Silicon PhotoMultiplier (ISiPM) topology
More informationA PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY
A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY BACKSCATTER DATA Young S. Ham and C.F. Poranski Materials Chemistry Branch Naval Research Laboratory Washington DC 20375 E.C. Greenawald Geo-Centers,
More informationForward Time-of-Flight Geometry for CLAS12
Forward Time-of-Flight Geometry for CLAS12 D.S. Carman, Jefferson Laboratory ftof geom.tex April 13, 2016 Abstract This document details the nominal geometry for the CLAS12 Forward Time-of- Flight System
More informationCorso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET
Corso di laurea in Fisica A.A. 2007-2008 Fisica Medica 5 SPECT, PET Step 1: Inject Patient with Radioactive Drug Drug is labeled with positron (β + ) emitting radionuclide. Drug localizes
More informationSPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.
SPECT QA and QC Bruce McBride St. Vincent s Hospital Sydney. SPECT QA and QC What is needed? Why? How often? Who says? QA and QC in Nuclear Medicine QA - collective term for all the efforts made to produce
More informationSupplementary Information
Supplementary Information Interferometric scattering microscopy with polarization-selective dual detection scheme: Capturing the orientational information of anisotropic nanometric objects Il-Buem Lee
More informationMedical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.
DXRaySMCS First User Friendly Interface Developed for Prediction of Diagnostic Radiology X-Ray Spectra Produced by Monte Carlo (MCNP-4C) Simulation in Iran M.T. Bahreyni Toosi a*, H. Moradi b, H. Zare
More informationA New Model for Optical Crosstalk in SinglePhoton Avalanche Diodes Arrays
A New Model for Optical Crosstalk in SinglePhoton Avalanche Diodes Arrays I. Rech, A. Ingargiola, R. Spinelli, S. Marangoni, I. Labanca, M. Ghioni, S. Cova Dipartimento di Elettronica ed Informazione Politecnico
More informationCBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona
CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona Introduction CBCT has become a routine procedure for
More informationCharacterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide
2005 IEEE Nuclear Science Symposium Conference Record M04-8 Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide J. S. Karp, Senior Member, IEEE, A. Kuhn, Member, IEEE, A. E. Perkins,
More informationImproved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images'
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 48, NO. 1, FEBRUARY 2001 111 Improved Modeling of System Response in List Mode EM Reconstruction of Compton Scatter Camera Images' S.J. Wilderman2, J.A. Fe~sle?t~>~,
More informationCrystal Identification in Dual-Layer-Offset DOI-PET Detectors Using Stratified Peak Tracking Based on SVD and Mean-Shift Algorithm
2502 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 63, NO. 5, OCTOBER 2016 Crystal Identification in Dual-Layer-Offset DOI-PET Detectors Using Stratified Peak Tracking Based on SVD and Mean-Shift Algorithm
More informationInvestigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers
Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Krista Chytyk MSc student Supervisor: Dr. Boyd McCurdy Introduction The objective of cancer radiotherapy
More informationAX-PET : A novel PET concept with G-APD readout
AX-PET : A novel PET concept with G-APD readout Matthieu Heller CERN - PH/DT Marie Curie network MC-PAD Matthieu.heller@cern.ch On behalf of the AX-PET collaboration https://twiki.cern.ch/twiki/bin/view/axialpet
More informationDUAL energy X-ray radiography [1] can be used to separate
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy
More informationA Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images
A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images Transfer Function Independent Registration Boris Peter Selby 1, Georgios Sakas 2, Stefan Walter 1,
More informationPerformance Evaluation of 3-Axis Scanner Automated For Industrial Gamma- Ray Computed Tomography
National Seminar & Exhibition on Non-Destructive Evaluation, NDE 2014, Pune, December 4-6, 2014 (NDE-India 2014) Vol.20 No.6 (June 2015) - The e-journal of Nondestructive Testing - ISSN 1435-4934 www.ndt.net/?id=17822
More informationProject GAMMA: Adaptive Methods for Medical Applications
Project GAMMA: Adaptive Methods for Medical Applications V. Solovov, A. Morozov, V. Chepel, V. Domingos, R.Martins, L. Pereira, F. Neves, A. Lindote, F. Fraga, I.Lopes, F. Alves LIP-Coimbra and Coimbra
More informationEstimating 3D Respiratory Motion from Orbiting Views
Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct. 2005 Funding provided by NIH Grant P01 CA59827 Motivation Free-breathing
More informationReconstruction from Projections
Reconstruction from Projections M.C. Villa Uriol Computational Imaging Lab email: cruz.villa@upf.edu web: http://www.cilab.upf.edu Based on SPECT reconstruction Martin Šámal Charles University Prague,
More informationDepartment of Game Mobile Contents, Keimyung University, Daemyung3-Dong Nam-Gu, Daegu , Korea
Image quality enhancement of computational integral imaging reconstruction for partially occluded objects using binary weighting mask on occlusion areas Joon-Jae Lee, 1 Byung-Gook Lee, 2 and Hoon Yoo 3,
More informationImpact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation
26 IEEE Nuclear Science Symposium Conference Record M6-349 Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation Habib Zaidi, Senior Member, IEEE and Mohammad
More informationRectification of distorted elemental image array using four markers in three-dimensional integral imaging
Rectification of distorted elemental image array using four markers in three-dimensional integral imaging Hyeonah Jeong 1 and Hoon Yoo 2 * 1 Department of Computer Science, SangMyung University, Korea.
More informationSPECT reconstruction
Regional Training Workshop Advanced Image Processing of SPECT Studies Tygerberg Hospital, 19-23 April 2004 SPECT reconstruction Martin Šámal Charles University Prague, Czech Republic samal@cesnet.cz Tomography
More informationThe optimum design of a moving PM-type linear motor for resonance operating refrigerant compressor
International Journal of Applied Electromagnetics and Mechanics 33 (2010) 673 680 673 DOI 10.3233/JAE-2010-1172 IOS Press The optimum design of a moving PM-type linear motor for resonance operating refrigerant
More informationSpectral analysis of non-stationary CT noise
Spectral analysis of non-stationary CT noise Kenneth M. Hanson Los Alamos Scientific Laboratory Int. Symposium and Course on Computed Tomography, Las Vegas, April 7-11, 1980 This presentation available
More informationTechnical Basis for optical experimentation Part #4
AerE 545 class notes #11 Technical Basis for optical experimentation Part #4 Hui Hu Department of Aerospace Engineering, Iowa State University Ames, Iowa 50011, U.S.A Light sensing and recording Lenses
More informationMinimizing Thin Glass Deflection in Flexible Display Manufacturing via Pin Map Optimization
Minimizing Thin Glass Deflection in Flexible Display Manufacturing via Pin Map Optimization Nam Hoon Jo BS. Scholar, Department of Mechanical Engineering, Graduate School Kongju National University (KNU),
More informationPerformance Evaluation of the Philips Gemini PET/CT System
Performance Evaluation of the Philips Gemini PET/CT System Rebecca Gregory, Mike Partridge, Maggie A. Flower Joint Department of Physics, Institute of Cancer Research, Royal Marsden HS Foundation Trust,
More informationFAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION
2009 IEEE Nuclear Science Symposium Conference Record M03-7 FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION Wonseok Huh, Jeffrey A. Fessler, Adam M. Alessio, and Paul E. Kinahan Department
More information(RMSE). Reconstructions showed that modeling the incremental blur improved the resolution of the attenuation map and quantitative accuracy.
Modeling the Distance-Dependent Blurring in Transmission Imaging in the Ordered-Subset Transmission (OSTR) Algorithm by Using an Unmatched Projector/Backprojector Pair B. Feng, Member, IEEE, M. A. King,
More informationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 5, OCTOBER
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 5, OCTOBER 2006 2549 Positioning Annihilation Photon Interactions in a Thin LSO Crystal Sheet With a Position-Sensitive Avalanche Photodiode Angela M.
More informationOptimization of scanner parameters for dual energy micro-ct
Optimization of scanner parameters for dual energy micro-ct E. PAUWELS* 1, J. DHAENE 1, A. DE MUYNCK 1 E., M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics and Astronomy, Ghent University, Proeftuinstraat
More information664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005
664 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 52, NO. 3, JUNE 2005 Attenuation Correction for the NIH ATLAS Small Animal PET Scanner Rutao Yao, Member, IEEE, Jürgen Seidel, Jeih-San Liow, Member, IEEE,
More informationLuminous. Optoelectronic Device Simulator 4/15/05
Optoelectronic Device Simulator 4/15/05 Contents Overview Key Benefits Applications Charge Coupled Devices (CCDs) Separate Absorption Multiplication (SAM) reach through avalanche photo detectors High speed
More informationUNIVERSITY OF SOUTHAMPTON
UNIVERSITY OF SOUTHAMPTON PHYS2007W1 SEMESTER 2 EXAMINATION 2014-2015 MEDICAL PHYSICS Duration: 120 MINS (2 hours) This paper contains 10 questions. Answer all questions in Section A and only two questions
More informationIntroduction to Emission Tomography
Introduction to Emission Tomography Gamma Camera Planar Imaging Robert Miyaoka, PhD University of Washington Department of Radiology rmiyaoka@u.washington.edu Gamma Camera: - collimator - detector (crystal
More informationGamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector
Gamma spectroscopic measurements using the PID350 pixelated CdTe radiation detector K. Karafasoulis, K. Zachariadou, S. Seferlis, I. Papadakis, D. Loukas, C. Lambropoulos, C. Potiriadis Abstract Spectroscopic
More informationISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry
ISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry Sasha A. Philips, Frazier Bronson, Ram Venkataraman, Brian M. Young Abstract--Activity measurements require knowledge of the
More informationSingle Polarizer Liquid Crystal Display Mode with Fast Response
Mol. Cryst. Liq. Cryst., Vol. 543: pp. 101=[867] 106=[872], 2011 Copyright # Taylor & Francis Group, LLC ISSN: 1542-1406 print=1563-5287 online DOI: 10.1080/15421406.2011.568342 Single Polarizer Liquid
More informationValidation of the Small Animal Biospace Gamma Imager Model Using GATE Monte Carlo Simulations on the Grid
Validation of the Small Animal Biospace Gamma Imager Model Using GATE Monte Carlo Simulations on the Grid Joe Aoun, Vincent Breton, L. Desbat, B. Bzeznik, M. Leabadand, J. Dimastromatteo To cite this version:
More information486 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 3, JUNE 2007
486 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 54, NO. 3, JUNE 2007 Count-Rate Dependent Component-Based Normalization for the HRRT Mario Rodriguez, Jeih-San Liow, Member, IEEE, Shanthalaxmi Thada, Merence
More informationBME I5000: Biomedical Imaging
1 Lucas Parra, CCNY BME I5000: Biomedical Imaging Lecture 4 Computed Tomography Lucas C. Parra, parra@ccny.cuny.edu some slides inspired by lecture notes of Andreas H. Hilscher at Columbia University.
More informationCOUNT RATE AND SPATIAL RESOLUTION PERFORMANCE OF A 3-DIMENSIONAL DEDICATED POSITRON EMISSION TOMOGRAPHY (PET) SCANNER
COUNT RATE AND SPATIAL RESOLUTION PERFORMANCE OF A 3-DIMENSIONAL DEDICATED POSITRON EMISSION TOMOGRAPHY (PET) SCANNER By RAMI RIMON ABU-AITA A THESIS PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY
More informationGPU implementation for rapid iterative image reconstruction algorithm
GPU implementation for rapid iterative image reconstruction algorithm and its applications in nuclear medicine Jakub Pietrzak Krzysztof Kacperski Department of Medical Physics, Maria Skłodowska-Curie Memorial
More informationEvaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT
Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT Qiao Yang 1,4, Meng Wu 2, Andreas Maier 1,3,4, Joachim Hornegger 1,3,4, Rebecca Fahrig
More information3D-OSEM Transition Matrix for High Resolution PET Imaging with Modeling of the Gamma-Event Detection
3D-OSEM Transition Matrix for High Resolution PET Imaging with Modeling of the Gamma-Event Detection Juan E. Ortuño, George Kontaxakis, Member, IEEE, Pedro Guerra, Student Member, IEEE, and Andrés Santos,
More informationin PET Medical Imaging
Fast Timing and TOF in PET Medical Imaging William W. Moses Lawrence Berkeley National Laboratory October 15, 2008 Outline: Time-of-Flight PET History Present Status Future This work was supported in part
More informationConflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program
James R Halama, PhD Loyola University Medical Center Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program Learning Objectives 1. Be familiar with recommendations
More informationNew Edge-Enhanced Error Diffusion Algorithm Based on the Error Sum Criterion
New Edge-Enhanced Error Diffusion Algorithm Based on the Error Sum Criterion Jae Ho Kim* Tae Il Chung Hyung Soon Kim* Kyung Sik Son* Pusan National University Image and Communication Laboratory San 3,
More information