LEITRONIC AG Swiss Security Systems. System GSM-Nano ( A) GSM-Nano
|
|
- Moses Mitchell Warner
- 6 years ago
- Views:
Transcription
1 491 GSM-Nano 1/16
2 Contents 1 Overview Specification Communication unit Nano Connectors EA-GSM-Interface Connectors Mounting Communication unit Nano GSM-Interface Wiring Start-up Accessories Indicators EA-GSM-Interface Communication unit Nano Programming over SMS Advanced settings Reply-SMS Automatic Status-SMS Troubleshooting Reception test Modem settings General settings Specific elevator controls Accessories Additional sub-communication unit in the cabin Retrofit material Short instruction for alarm point Answering calls Callback into cabin Maintenance protocol Values of the reception test ( 9) note within each maintenance /16
3 1 Overview The elevator alarm system GSM Nano is conform to EN81-28 and EN81-7. The connection between the communication unit Nano and the EA-GSM-Interface needs two wires only (existing wires of alarm-horn may be used). The emergency call over GSM is a cost effective alternative to landline installation. No costs for an analogue landline. You may change the provider at any time. The elevator can already be used during construction. Programming over SMS (Calling numbers, identification and parameters). Connectivity for emergency button, misuse-protection-signal and external emergency light. Interface to connect to the elevator control (e.g. Böhnke+Partner, Kollmorgen, KW, L+L, Newlift, Rekoba, RST, Strack etc.) use as GSM-Modem. Safety note The location of the GSM-antenna should be stationary (e.g. in the machine room) in order that a stable reception is guaranteed. In case of an emergency call retro-fit (SNEL, ESBA), where no empty wires in the hanging cable are available, the EA-GSM-Interface can be located on top of the cabin, providing that the GSM reception is guaranteed for the entire cabin travel (Simple GSM reception diagnosis by SMS). If the GSM reception is inadequate or fails completely, the elevator must automatically be set out of order: for example, command to the elevator control to move to the ground floor. Therefore the EA-GSM-Interface provides a relay contact (NO or NC). Beware of using prepaid cards: in case of an emergency there might be no credit left. Better use a subscription or prepaid with topping up via auto reload. To ensure that the correct number is dialled even with roaming, the calling numbers must be entered including the country code. 3/16
4 2 Specification 2.1 Communication unit Nano Article-No: Power supply: Dimension (L x W x D): Housing: Weight: 1.9 from EA-GSM-Interface 112 x 56 x 21 mm ABS transparent 1 g EXT SW E_LED LED indicator Green Yellow LINE EC MISUSE Flashes every 5 seconds (1x=NO, 2x=NC): Nano is ready Permanent on: during voice connection During Misuse-protection, time-out and dial-up Connectors EC Emergencycontact LINE Potential free emergency-contact Automatic detection of the contact type on power (e.g. voltage on LINE). NO = Normally open (1xPiep and every 5s a green flash) NC = Normally closed (2xPieps and every 5s a green double-flash) Connect communication unit over two wires with the EA-GSM-Interface. E_LED Emergencylight Notes: Check polarity same polarity as on EA-GSM-Interface If the polarity is wrong the emergency light is on continuously. For retro-fits you may use the existing two wires of the siren. The siren is then connected to the switched output (+12V-Siren and +12V-GND) of the EA-GSM-Interface. Misuse-protection door-signal-input: (active) = 1 to 5 V AC or DC If during this time-out (= max. travel time) the door-signal changes, the emergency call will be stopped. Emergency-light output for external LED: 6V DC / 2 ma The emergency-light is on in case of a mains loss on the EA-GSM-Interface and in case of any failure 7.3. EXT SW = Slide switch. Switches between internal LED and external emergency-light e.g. for connecting an additional sub-communication unit EA-LMC7 MISUSE Left detail EXT SW E_LED 4/16
5 2.2 EA-GSM-Interface Article-No: Power supply: 1.84A 23 VAC/5Hz/<15 W Standby: 5 W + 2 W during connection + load on 12V + 5 W during battery charge (max) Backup battery: 12 V / 1.2 Ah (1.88) Typical charging time: 8 h GSM: Dual-Band 9/18 MHz Dimension (L x W x H): 24 x 191 x 17 mm Housing: ABS, IP65 Weight: 11 g (without battery) Connectors ANT ALM BATT EXT F1 F2 LINE RJ12 LINE 23V GSM-Antenne SMA Alarm-input: Connector for 12 V / 1.2 Ah battery Data interface Mains fuse Battery fuse Connection to communication unit Nano Connection to communication unit Nano Mains plug READY Relay: Operation control: System ready SIM SW1 SIM-card holder Mode switch 12V Emergency power max. 25 ma GSM-Antenna 1,2: active if signal V AC or DC 1: +BATT (red) 3: -BATT(black) For modem use 63 ma slow 6.3 A slow 3: +LINE (Nano) 4: -LINE (Nano) 1: -LINE (Nano) 2: +LINE (Nano) 1: Neutral 2: Earth 3: Phase (F1) 1: Normally closed contact (NC) 2: C 3: Normally open contact (NO) Set SIM-PIN to OFF: GSM-Modem use only (transparent) PROG: Programming of EA-GSM-Interface ON: Emergency call and GSM-Modem use 1: +12V-Siren *) 2: GND 3: +12V-UPS (uninterrupted power supply) *) the output is active, - as along as the emergency button is active - if the communication unit Nano is not connected - in case of any problem (short tone every 1s, can be switched off 7.1) 5/16
6 3 Mounting 3.1 Communication unit Nano ce mounted, the speaker and the microphone in particular should not be covered, otherwise the communication quality decreases (reduced volume, poor hands free quality). Make sure the microphone hole and the panel hole fit. The sub-communication unit must be mounted directly behind the panel without any gap, otherwise there will be an acoustic feedback. If necessary insulate speaker and microphone room acoustically using foam or rubber. Panel Nano Nano foam or aligned Nano For mounting accessories (panels, drilling templates, transparent frames, emergency lights, etc.) have a look at our special document GSM-Interface Find a suitable location for the EA-GSM-Interface according to the reception intensity indicator on the mobile phone. Recommendation: stationary location in the machine room or shaft assembly, not in the vicinity of radio transmitters and interference sources. If there are no free wires in the hanging cable, the EA-GSM-Interface can be mounted on top of the cabin. In any case, the GSM receive must be checked over the entire travel of the cabin 9. Check Reception! Note that the level-indicator may be delayed. 6/16
7 Adjust RDT 1 The device has been designed solely for operation on a 23 VAC / 5 Hz supply. Work on the 23 VAC power supply must be carried out by a qualified electrician. Doing so the applicable accident prevention regulations must be observed, to avoid electric shock, the mains has to be disconnected (trip the circuit breaker). 4 Wiring 7/16
8 5 Start-up Connect communication unit, alarm-horn and emergency button according to wiring plan. Insert SIM-card with PIN set to. To set PIN to use any mobile phone. **4* <old PIN>**# + Connect battery Turn on 23V mains. After two minutes the LEVEL indicators are showing the GSM reception. LED_COM flashes green every 3 seconds. Stick the antenna where the LEDs LEVEL show maximum reception. If you call NANO, the unit indicates sound while ringing and activating the green LED (speak). You may now record the individual announcement (identification) 12. The calling-numbers can be programmed via SMS, by sending an SMS towards NANO 7. A short pressing of the emergency button activates the alarm-horn. If you press longer than the programmed debounce time-out, you will hear a dial tone during the selected misuse time-out. If there is no change of the MISUSE signal the first calling-number will be dialled. 5.1 Accessoires Picture Supply Battery 12 V / 1.2 Ah 1.117, 1.8x and 1.81x Picture Picture Picture Antenna accessories for all GSM-modules 1.8x and 1.81x Art. No. External GSM-Antenna cable 5m Antenna-Extension-cable cable 1m Serial interface Art.No. Data-Module DB9 serial interface for elevator controls DB Data-Module USB interface for elevator controls MiniUSB Remote-communication unit to communicate with cabin GSM-MR (DIN-mounting, pluggable screw terminal and RJ12-jack) Machine room solution extension for DTMF capable telephone i.e Art. No. Wall mount telephone incl. cable 3m machine room solution Picture Art.No Other accessories EA-LMC7 (pluggable screw terminal and RJ45-jack) Supply voltage: 8-35 V DC i.e. +12V from EA-GSM-Interface or EA-GSM-DIN 2xEN81-7 indicator (yellow/green): internal with light pipes, external symbols 1xInput for emergency button: potential free Art.No LMC-EC (pluggable screw terminal and RJ45-jack) 1xEmergency-Button (Normally open: integrated or external) 1xMicrophone + 1xSpeaker EC-MIC (screw terminal and RJ45-jacks) 1xEmergency button 1xMicrophone V-SIR siren horn 1.2 8/16
9 6 Indicators 6.1 EA-GSM-Interface LED_COM Green Red Blue SIM-error: flashes every 1/2 second During network registration: flashes every second Flashes every 3 seconds if connected to the GSM network Communication unit Nano connected Elevator control in connection: over serial interfaces LEVEL 23V BATT Normally showing the GSM-reception level GSM Level poor GSM Level low GSM Level medium GSM GSM Level high REC GSM Level excellent LED In case of an error the LED shows error code 1_LEVEL is inactive Inactive LED2..5 showing errors *) Problem with supply voltage Problem with battery/charging Problem with GSM-Network or Roaming or Nano not connected to LINE Problem with GSM-reception (Level Alarm) *) Error analysis by Status-SMS: send SMS with content PIN: Reply-SMS 7.3 LED EL OK (READY) Indicator of the alarm-horn output Ready-indicator for GSM-Interface, if Battery and battery-charging ok SIM-card inserted with correct SIM-PIN GSM-reception sufficient Otherwise the elevator may not perform any further trips. Note: OK (READY) can be delayed up to two minutes (GSM-reception) 6.2 Communication unit Nano LED Green Yellow Flashes every 5 seconds (1x=NO, 2x=NC): Nano is ready Permanent on: In voice connection During Misuse-protection time-out and dial-up 9/16
10 7 Programming over SMS Programming is done by SMS. An SMS containing PIN: will be evaluated and answered 7.2 to the sender. All commands are written in CAPITAL LETTERS. SMS-Commands Reply-SMS Default-PIN: PIN: leitronic.ch Nano Note: PIN 4-digits V.F.x.y ready NEW:1234 CALLNx=<Calling-No.> CALLN1 to CALLN9 will be called until DTMF acknowledges call ALARM=<Alarm-number> ALARM=OFF RESET Change PIN to 1234 and activate SIM-card protection Note: PIN 4-digits Calling-numbers x=1..9 completed with a space (max. 24 digits) CALLN9 (Routine-No.) New Pin:1234 Status-SMS number with +country code e.g. +41 completed with a space (max. 24 digits) Disable Status-SMS Set to factory defaults Alarm:<Alarm-number> CallNx:<Calling-number> Alarm:OFF Reset 7.1 Advanced settings Advanced settings can be read-out or changed as following: EE_R:<adresse> EE_W:<adresse>=<value> <adresse> Read EEPROM <adresse> is 4-digits Write EEPROM <adresse> is 4-digits <value> is 3-digits (..255) Function Signal errors on alarm-horn Connection time-out Debounce time: Emergency button (Nano) Debounce time: Alarm-input ALM until StatusSMS Routine call interval (CALLN9) Misuse protection time=max. cabin travel time Announcement every x seconds adr:<adresse>:<read out value> adr:<adresse>:<written value> <value> disabled 1 enabled 3 to 255 s to 255 * 2ms to 255 * 2ms Default 1 to 255 h to 255 s off 1 to 255 s = 1s 5 = 1s Example: PIN=, Calling-No. 1: , Calling-No. 2: , Routine-No. 9: , Status-SMS: , max. cabin travel time= 2 s send SMS with content PIN: CALLN1= CALLN2= CALLN9= ALARM= EE_W:24=2 Reply-SMS leitronic.ch Nano V.F.x.y ready, CallN1: CallN2: , CallN9: , Alarm: , adr:24:2, Batt:96, Ri:18, Charge:255, Power:34, last Call:26, Rssi:12(9-15), Ber:(-2), Errors:----+,-----,--- (limited to 16 characters) 1/16
11 7.2 Reply-SMS Example of a Reply-SMS: leitronic.ch Nano V.F.x.y xx,(adr:<adresse>:<value>),(new Pin:<new PIN>), (Alarm:<alarm number>), Batt:xx, Ri:xx, Charge:xx, Power:xx, last Call:xx, Rssi:xx(xx-xx), Ber:xx(xx-xx), Errors:-----,-----,--Label Value xx Info Nano ready Status System ready to use V.F.x.y Software-Version not ready System not ready Batt: Battery voltage to 97 Calculate voltage:.145 * <value> e.g V or V Ri: Battery-resistance 1 to battery o.k. defect! Battery- or Fuse F2 Battery failure or blown fuse F2 6.3AT defect check and replace Charge: Battery charge value to 255 Charge: * 255s / Discharge: * 15s Power: Battery charging to Supply voltage missing voltage 28 Supply voltage too low to charge battery 34 Supply voltage sufficient last Hours since last call to 255 in hours Call: Roaming GSM-Roaming Not home GSM-network => higher costs Rssi: GSM-Level to 31 Calculate level: 2*<Value> - 113dB <mom> Momentary e.g. 1 2*1-113 = -93db (<min>- Min. since last call GSM poor 5 LED1 <max>) Max. since last call GSM low 1 LED2 GSM medium 15 LED3 GSM high 2 LED4 GSM excellent 25 LED5 Ber: BitErrorRate to 7 : minimum BitErrorRate <mom> Momentary 7: maximum BitErrorRate (<min>- Min. since last call <max>) Max. since last call Errors Error-No. to 12 -+*, -: inactive e.g ,---*-,--* *: active,: separator before error 5/1 +: delayed error not jet active Example: Change PIN from to 1234, set Alarm to , set EEPROM 18 to 1 send SMS with content PIN: NEW:1234 ALARM= EE_W:18=1 Reply-SMS leitronic.ch Nano V.F.x.y ready, New Pin:1234, Alarm: , adr:18:1, Batt:96, Ri:18, Charge:255, Power:34, last Call:26, Rssi:12(9-15), Ber:(-2), Errors:--*-+,-----,-- Error 2 active: GSM bad and Error 4: Supply voltage too low (in delay) If you do not get any Reply-SMS, please check the following points: a) b) c d) e) EA-GSM-Interface is not connected to the GSM-network + check LED_GSM PIN-Code is incorrect SIM number is incorrect No money left on SIM-card Mode switch SW1 not on ON 11/16
12 7.3 Automatic Status-SMS The Status-SMS will be sent to the defined alarm-number ALARM=, completed with a space. To disable the Status-SMS send SMS with content: PIN: ALARM=OFF Test interval Send Restore Restore-SMS content Example: Signal on input ALM SMS with content: leitronic.ch Nano V.F.x.y ready, Alarm X4, Batt:96, Ri:18, Charge:255, Power:34, last Call:26, Rssi:12(9-15), Ber:(-2) Errors:*----,-----,--- (5)* 2ms - No Alarm X4 - Power on - GSM ok - Home Power not poor - Routine call ok Emergency ended *) Emergency light Delayed Send Alarm SMS content 1 Alarm X4 / ALM Off Alarm X4 1 Supply voltage missing - Power off 2 GSM poor 15 s GSM poor 2s 3 GSM Roaming Roaming 2s 15 s Power poor Errors READY (OK) Error code LED < State / Error> Supply voltage too low to charge battery No call within routine interval Unacknowledged calls Battery not charged within 24 h No or bad battery or fuse F2 defect or battery test circuit defect (Ri<1) 9 GSM bad 15 s 1 No GSM network or not registered or mode switch SW1 not on ON 11 Nano not connected 12 Battery end Off No routine call Emergency Call Charge problem off could be on on (74) h 24 h Battery failure 1h Battery ok GSM bad 2s GSM ok No GSM Line problem 1h Battery end 2s Charge ok GSM registered Line OK Charging *) Emergency ended: Door-state changes / Alarm acknowledged by DTMF / New connection 8 Troubleshooting Faults and errors are displayed by the various indicators (LED) 6 Detailed error information available through a status inquiry via SMS or automatically by StatusSMS in case of a new error (if <Send Alarm> is Table) send SMS with content PIN: Reply-SMS /16
13 9 Reception test 1. If the EA-GSM-Interface is mounted on the cabin roof, send the cabin to the location with the worst GSM reception (check reception with LED1..5). Attention: The level-indicator may be delayed. 2. Start test call and check if the connection is established terminate test call. 3. Re-start test call + Connection must be established + Stay in connection and move the cabin over the complete shaft Check if connection remains stable + Terminate test call + Send SMS to verify GSM-levels: Rssi:<mom>(<min>-<max>) The minimum value <min> must be higher than 5! Report Rssi-Value with date (see last page)! 4. If a problem occurred during test, change or optimize the placement of the EA-GSM-Interface. 5. If you cannot find an improved placement use an external antenna e.g. Article-no and / or extension cord Modem settings 1.1 General settings <adresse> function Auto-Answer ATS=<n> Select Baud rate for transparent mode 126 Quiet-Mode (Modem does not answer or indicate RING) 128 Result-Code <value> <n> =96 1=192 =disabled (ATQ) 1=enabled ATQ1) Default 1 =Text (ATV1) 1=Numerical (ATV) If modem should work in transparent-mode, you have to configure by SMS as following: Example: PIN is. Modem with 192 Baud, Auto-Answer after four cycles, Quiet-Mode enabled send SMS with content PIN: EE_W:4=4 EE_W:125=1 EE_W:126=1 Reply-SMS leitronic.ch Nano V.F.x.y ready, adr:4:4, adr:125:1, adr:126:, Batt:96, Ri:18, Charge:255, Power:34, last Call:26, Rssi:12(9-15), Ber:(-2), Errors:----+,-----, Specific elevator controls refer to special document: 13/16
14 11 Accessories 11.1 Additional sub-communication unit in the cabin The two emergency call buttons EC inputs are connected in parallel, e.g. attach either two normally open contacts (NO) to both EC-inputs or two normally closed contacts (NC) in series to one EC-input Retrofit material See individual document 14/16
15 12 Short instruction for alarm point 12.1 Answering calls Accept call Indication on communication unit The called party can initiate the following remote-commands: DTMF key or 3 **# Terminate call Renew connection for another 12 seconds Play individual announcement (Identification) In case of an alarm call: Terminate connection and call next alarm-number In case of callback into cabin: Terminate connection and call number 8 Record individual announcement (12 seconds). After recording the new text will be announced. Each call must be terminated by key. Otherwise GSM-Nano calls the next alarm-number. If the alarm remains unacknowledged, a Status-SMS will be sent with contents: leitronic.ch Nano V.F.x.y ready, Emergency Call, Batt:96, Ri:18, Charge:255, Power:34, last Call:26, Rssi:12(9-15), Ber:(-2) Errors:-----,*----,--If there is a change of the door-state a Restore-SMS will be sent: leitronic.ch Nano V.F.x.y ready, Emergency ended, Batt:96, Ri:18, Charge:255, Power:34, last Call:26, Rssi:12(9-15), Ber:(-2) Errors:-----,*----, Callback into cabin Call telephone number of the GSM-Nano. Ten seconds later you are connected with the cabin Indicated in the cabin by 15/16
16 13 Maintenance protocol Location of the installation : System GSM-Nano installed by: Company:. Mechanic:. Date:. Calling number of SIM-card:. PIN-Code of SIM-card: Values of the reception test ( 9) note within each maintenance Status query by SMS send SMS with content PIN: Reply-SMS.. Rssi:<mom>(<min>-<max>).. Write down the three Rssi-values of the Reply-SMS into the table below: e.g. Rssi:12(9-18) momentary=12, minimal=9, maximal=18 The minimum value must be higher than 5! Date Tested by <mom> Mister Sample 15 Rssi: <min> >5! 9 <max> 18 16/16
EA-GSM-Interface-GB.odt
EA-GSM-Interface (1.8/1.82) 4/7/213 EA-GSM-Interface GSM-Gateway +41 ()56 648 4 4 / www.leitronic.ch 1/12 EA-GSM-Interface (1.8/1.82) 4/7/213 Contents 1 Overview... 3 2 Specification... 4 2.1 Connectors...
More informationLEITRONIC AG Swiss Security Systems EA-GSM-DIN. GSM-Gateway
EA-GSM-DIN (1.812) 13/8/213 EA-GSM-DIN 4813 GSM-Gateway +41 ()56 648 4 4 / www.leitronic.ch 1/12 EA-GSM-DIN (1.812) 13/8/213 Contents 1 Overview... 3 2 Specification... 4 2.1 Connectors... 4 3 Mounting...
More informationEasyAlarm GSM-Nano Mini
Retrofit-Material for EasyAlarm GSM-Nano Mini Contents 1 Panels for communication units... 2 1.1 Retrofit panel with / without emergency button (Inox/Polycarbonate)...2 1.2 Emergency-button adapter EA-NT-IN...
More informationRUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming
RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK-1201 Assembled by : Engineer: Installation date : Phone number elevator : PIN : PUK: Battery changed on date : Name : Keep this manual on a save place,
More informationLEITRONIC AG Swiss Security Systems
Table of contents 4224 Fire brigade solution according to EN8-72... 2.Overview... 2.2Required components... 3.2.In the cabin... 3.2.2On the fire brigade location and in the machine room...3.3installation:
More informationA1000 GSM ALARM DEVICE
A1000 GSM ALARM DEVICE USER MANUAL A1000-REV2.1-1604 FW-A1000v2.93 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for installation,
More informationThe Packs Infotel. GSM Converter V2. Installation Manual V7
The Packs Infotel GSM Converter V2 Installation Manual V7 1 Index Connecting the M60 to the GSM Converter 3 1. GSM Converter description 4 2. Equipment installation 4 3. Led functions. 5 4. GSM Converter
More informationInstallation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation
-V/AB & ABK V.5 (2 ) Important Notes: ) Before you install this equipment, please read this full manual. Installation Manual Wiring 8) Carefully follow the wiring instructions. 2) Before fully installing
More informationUP100-GSM. GSM based intercom and access control. Installation and user manual
UP100-GSM GSM based intercom and access control Installation and user manual UP100-GSM REV.1.4 20/01/2014 Table of contents 1 Functions...3 2 Features...3 3 Application area...3 4 Operation...3 4.1 Visitor
More informationInstallation Manual & User Instructions
Installation Manual & User Instructions For BFT Americas. Inc. 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 Toll Free: 877-995-8155 Office: 561-995-8155 Fax: 561-995-8160 1 P a g e M u
More informationLEITRONIC AG Swiss Security Systems
Table of contents 4224 Fire brigade solution according to EN8-72... 2. Overview... 2.2 Required components... 3.2. In the cabin... 3.2.2 On the fire brigade location and in the machine room...3.3 Installation:
More informationInstallation Manual & User Instructions. MultiCom 100 / 500
Installation Manual & User Instructions For MultiCom 100 / 500 Multi apartment GSM Intercom System 1 P a g e M u l t i c o m 1 0 0 i n s t a l l i n s t r u c t i o n s v 1 Contents Section Description
More informationAristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01
Aristel Networks Pty Ltd All Round Cabling Solutions NEOS3003-3G01 Operating Manual * NEOS 3003-3G01 Supports 3G/UMTS 800/850/900/1900/2100 MHz bands Telstra-Vodafone-Optus supported in all areas. * Model:
More informationBlue Gate A Brave Installation guide V 2.4
G S M G A T E Blue Gate A Brave Installation guide V 2.4 Basic features: Blue Gate A Brave is dual band GSM Gate based on Telit GL865 equipped by a lot of adjustable features increased comfort of service.
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More informationInstallation Manual & User Instructions. MultiCom 500
Installation Manual & User Instructions For MultiCom 500 Multi resident GSM Intercom System Contents Section Description Page 1 Introduction 3 2 Getting started 3 3 SIM card 3 4 Wiring 4 5 Keypad / onscreen
More informationLink GSM idp Manual v1.0
Link GSM idp Manual v1.0 Please find the latest version of the manual and firmware at www.linkcom.fr Table of Contents 1. Basic features:... 3 1.1 Function:... 3 2. Installation... 4 2.1. Assembly of front
More informationA1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1
A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for
More informationSMS Transceiver V3 User manual
SMS Transceiver V3 User manual SMS Transceiver V3 - User manual ver. 1.8.3 - Fw: 3.0.7 - Sw: 1.6.2 Contents Page 1. Introduction 3 2. Connections 3 2.1 Inputs 3 2.2 Outputs 3 2.3 Power supply 3 2.4 Contacts
More informationGSM SECURITY AND CONTROL SYSTEM ESIM021
GSM SECURITY AND CONTROL SYSTEM ESIM021 Manual v1.1 Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around: Alarm and control system
More informationSTD Simple Telemetry Application. Owner s Manual
STD47 1.0 Simple Telemetry Application Owner s Manual Table of Content 1. Safety Information... 4 2. Main Functions:... 5 2.1. Start-Up alarm message... 5 2.2. Digital Output control:... 5 2.3. Digital
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC
More information8848 GSM FWT (GATEWAY) USER S MANUAL
8848 GSM FWT (GATEWAY) USER S MANUAL 1 1, General Description: ET-8848 is a GSM to Analog Converter (single port, insert 1 SIM card only), the device can produce a FXS line to allow a regular phone to
More informationUSER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n
USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H SW version 3.n CONTENT 1. General description 1 2. Getting started 2 2.1 Insert a SIM card 2 2.2 Insert the batteries 2 2.3 Enter the
More informationUser Manual. GSM Fixed Wireless Phone (Model: GSM-938) Introduction
User Manual Introduction The latest style desktop wireless telecommunication products. It can send wireless SMS and voice at anytime, anywhere, suitable remote countries or mountains. Please take care
More informationVOICE and/or DATA CELLULAR SYSTEM
... VOICE and/or DATA CELLULAR SYSTEM The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE network where available. The system provides voice
More informationPowerware 3105 UPS User s manual
Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care
More informationVOICE and/or DATA CELLULAR SYSTEM
... VOICE and/or DATA CELLULAR SYSTEM This cellular device cannot be used for 9 calls. The Voice/Data or Data Only Cellular System operates on DoorKing s cellular network that is hosted on the AT&T G LTE
More informationProLine GSM. Installation manual
Installation manual ContentS Description of device functions... page 3. Line simulkator function... page 3. Description of the terminal block... page 4. Installation instructions... page 4. LED signals...
More informationProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4
informacije in naročila: info@gsm-komunikatorji.com.gsm-komunikatorji.com ProCon GSM INSTALLATION AND APPLICATION MANUAL for module version 1.4 1 Index I. Basic descriptions... 3 II. Steps of installation...
More informationGSM GATE VT 10. version 5.4 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC, Issued on May 16, 2007
Gate VT 10 GSM GATE VT 10 version 5.4 and higher Installation manual VARIANT plus, spol. s.r.o., U Oburky 5, 674 01 TREBIC, technik@variant.cz www.variant.cz Issued on May 16, 2007 VARIANT plus s.r.o.
More informationNxtG-V Install Manual
NxtG-V Install Manual 1. Product Overview 1.1. Check Parts List Before starting, check whether all the following items have been included with your NxtG-V. If anything is missing, please contact your supplier.
More informationPowerware 3105 UPS User s manual
Powerware 3105 UPS 2005 Eaton Corporation All Rights Reserved The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) unless permission granted. Every care
More informationEAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06
Instruction Manual EAS DIGITAL/ANALOG OVERRIDE INTERFACE Model 988 PC Software version 1.06 Emergency Alert Systems CATV Switching and Control 585-765-2254 fax 585-765-9330 100 Housel Ave. Lyndonville
More informationEmergency Dialer DIAL-ALERT MODEL: AD-433S.
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: AD-433S 101A118 FEB, 2000 SKYLINK TECHNOLOGIES INC., 2213 Dunwin Drive, Mississauga, Ontario L5L 1X1 CANADA Tel : (905) 608-9223 (800) 304-1187
More informationTroubleshooting Guide for Firecom Intercoms
A) I have a problem with Interior Communications - Headset to Headset I cannot communicate between headsets and I cannot hear myself in my own headset. I cannot communicate between headsets but I do hear
More informationMobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs
MobilTherm 2ad GSM temperature alarm module with auxiliay inputs and relay outputs The MobilTherm-2ad is a GSM temperature and remote signaling module, designed for GSM based remote control, remote signal.
More informationMobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output
Mobil Switch-Nano Industrial grade GSM signalling and remote control module with common input and relay output The MobilSwitch-Nano module is a general, industrial-grade GSM module, developed for remote
More informationGSM AD05 Slave GSM Auto Dialer- Instruction Manual
GSM AD05 Slave GSM Auto Dialer- Instruction Manual Please read these instructions before you start the installation Features LCD display Programmable 9 x 32 digit phone numbers for each trigger. 10 second
More informationContent of delivery - GSM Gateway, art no Antenna SMA, magnet foot, art no GSM Gateway Manual (this document), art no.
Content of delivery - GSM Gateway, art no. 202236 - Antenna SMA, magnet foot, art no. 112322 - GSM Gateway Manual (this document), art no. 162236M - Power adapter 230VAC/12 VDC, art no. 132010 - Modular
More informationGC 055. GSM Remote Monitoring. Operating and installation instructions
GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas
More informationjcmtechnologies GSM-CARD/VGSM-CARD user s manual communications card
jcmtechnologies user s manual GSM-CARD/VGSM-CARD communications card EN Contents Safety instructions 3 Introduction 4 General description 4 Introduction 6 Assembly 6 Configuration 7 Verification 8 LED
More informationSMS TEXT DIALLER INSTALLATION AND OPERATION MANUAL
SMS TEXT DIALLER INSTALLATION AND OPERATION MANUAL Flashing Light (Text Message Received) Permanent Light (In Alarm) Optional Battery Backup SIM Card Carrier (see how to insert SMS card later in this manual)
More informationGSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,
Pager VT 21 manual II GSM PAGER VT 21 Installation manual VARIANT plus, spol. s.r.o., U Oburky 5, 674 01 TREBIC, www.variant.cz technik@variant.cz Date of create 16. 5. 2007 VARIANT plus s.r.o. VARIANT
More informationOT EASY 60 II. LED control unit Operating instructions
II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions
More informationGSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION
GSM Communicator GJD710 PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE YOU START THE INSTALLATION THIS EQUIPMENT WILL NOT WORK ON THE FEATURES NETWORK LCD display showing text in any of 8 different languages
More informationSuperBus 2000 Phone Interface/Voice Module Installation Instructions
SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module
More informationShort guide. Trackunit 401 SmartID. Version 1.4, June 2014
Short guide Trackunit 401 SmartID Version 1.4, June 2014 Mounting instructions Placement of the unit on the machine Do NOT mount the unit horizontally. Make sure that water can run off the unit. Do NOT
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More informationAristel Networks Pty Ltd NEOS Port GSM / 3G* Fixed Wireless Terminal
NEOS 4000 For models: 4 Port GSM / 3G* Fixed Wireless Terminal NEOS 4000-01 (GSM900/1800) NEOS 4000-02 (GSM 850/900/1800/1900) *NEOS 4000-3G (Next G & 3G) Operating Manual NEOS4000 SERIES Operating MANUAL
More informationGSM Interfacing Board
Campus Component Pvt. Ltd. DISCLAIMER Information furnished is believed to be accurate and reliable at the time of publication. However, Campus Component Pvt. Ltd. assumes no responsibility arising from
More informationMobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs
MobilSwitch-5c Multi channel GSM signaling and remote control unit with analog, digital, counter inputs The MobilSwitch-5c GSM device is developed for industrial signaling and remote controlling purposes.
More informationMobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs
MobilSwitch - Micro General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs The MobilSwitch-Micro module is a general, industrial-grade GSM module, developed for
More informationUSER MANUAL Mobeye CM-Guard CM2000
USER MANUAL Mobeye CM-Guard CM2000 SW version 3.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.
More informationGSM communicator GD-06 Allegro Complete manual
GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or
More informationInstalation manual to GSM dialer with mobile phone FVK 41 EZS
Instalation manual to GSM dialer with mobile phone FVK 41 EZS 1 Contents: 1. Basic information...3 1.1 Description of device...3 1.2 Posibilities of use...3 1.3 Specifications...3 1.4 Package content...3
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately
More informationMANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments. For your protection, read these instructions completely
MANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments For your protection, read these instructions completely And keep them for future reference. TABLE OF CONTENTS IMPORTANT
More informationLX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011
LX8 emfone Installation and Configuration TVL No. 336 Issue No. 1 03/10/2011 Thames Valley Controls Unit 15 Manor Farm Industrial Estate Flint Flintshire CH6 5UY T: +44 (0) 1352 793222 F: +44 (0) 1352
More informationMultiModem rcell. Intelligent Wireless Router. Quick Start Guide
MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2 82100400L, Revision A Copyright 2009 by Multi-Tech Systems,
More informationConversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages
GSM ProCom Description GSM and PSTN communication Management of 2 independent SIM cards Reception of incoming calls, possibility for restriction Installable behind PBX Management of different prefix numbers
More informationUser Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA
User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage.
More informationZartek. CDP-808 Two Button Wireless Intercom Installers Manual
Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with
More informationNanoServ. Setup Guide. Thin System/Ultra-Thin System. 1.0 What s included with the NanoServ. 2.0 Steps for setting up the NanoServ
NanoServ Thin System/Ultra-Thin System Setup Guide 1.0 What s included with the NanoServ The following items are included with the NanoServ : 1. NanoServ 2. AC Power Adaptor 3. CD-ROM with User s Manual
More informationUniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany
LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More informationSMS Commander Manual
SMS Commander Manual For the GB0101S V1.2 Before Attempting to connect or operate this product, please read these instructions in its entirety, especially the guarantee conditions. TABLE OF CONTENTS Introduction...3
More informationAV-4000 GSM AV-4000 DVR
E a s y L o a d e r AV-4000 GSM AV-4000 DVR (for LED keypads) Integrated Alarm Control panel & Communicator Series 4000 Appendix for GSM Alarm Panels Version 1.05 Edition I This product is subject to continuous
More informationSC-688 GSM FWT USER S MANUAL
SC-688 GSM FWT USER S MANUAL 1,General Description: SC-688 is a GSM to Analog Converter(single port,insert 1 sim card only), the device can produce a FXS line to allow a regular phone to be connected and
More informationGPS Vehicle and personal location tracker
Version Number Modified by Change Content Type Date V1.0 Amy create 2014.06.23 GPS Vehicle and personal location tracker User Manual GPS Vehicle and personal location tracker User Manual 1 Contents 1.
More informationDialler HA2000 RTC. Installation & Operating Manual
Dialler HA2000 RTC Installation & Operating Manual The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a tabletop before
More informationDE EN. TeLephOne ReMOTe COnTROL FOR Eberspächer parking heaters A WORLD OF COMFORT
Vehicle heaters Technical Documentation DE EN Installation instructions Calltronic TeLephOne ReMOTe COnTROL FOR Eberspächer parking heaters A WORLD OF COMFORT 2 Vehicle Heaters Technical Documentation
More informationEATON 5S 850/1200/1600
www.eaton.com EATON 5S 850/1200/1600 Installation and user manual Packaging EATON 5S 1 2 3 5 Caution! l Before installing the Eaton 5S, read the booklet 3 containing the safety instructions to be respected.
More informationGPRS Pager 3 INSTALATION AND USER MANUAL
GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation
More informationINTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual
INTERQUARTZ Doorphone ID 201 Doorphone ID 202 Doorphone ID 204 User manual Contents 1 BASIC DESCRIPTION... 3 1.1 FEATURES... 3 1.2 SLIMDOORPHONE MODELS... 4 2 INSTALLATION... 4 2.1 OPENING, WIRING, WALL
More informationEmergency Dialer DIAL-ALERT MODEL: ED
www.skylinkhome.com Emergency Dialer TM DIAL-ALERT MODEL: ED-100 101A083-002 FEB, 2006. CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (905) 456-8883 Fax : (905) 456-7819 Email
More informationGPS Vehicle and personal location tracker. User manual
GPS Vehicle and personal location tracker User manual 1 Contents 1. Product overview... 2 2. Safety instruction... 3 3. Specification and parameters... 3 4. Getting started... 4 4.1 Hardware and accessories...
More informationMobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers
MobilGate - 128d Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers MobilGate-128d is an industrial GSM module developed for remotely controlling doors, garage doors
More informationSafeLine GL5. Installation manual. A GSM alternative for all of our lift telephones with built-in power supply and battery backup.
SafeLine GL5 Installation manual A GSM alternative for all of our lift telephones with built-in power supply and battery backup. SafeLine GL5 Installation manual TECHNICAL DATA Communication: Antenna connector
More informationUniversal communications device Metcom T A..
Universal communications device Metcom T A.. Manual Order-No. E 858-102 1 2 3 4 5 6 7 8 1 RUN-LED for power on 2 RI-LED: Ring Indication 3 DCD-LED: Data Carrier Detect 4 RxD-LED: Receive Data 5 TxD-LED:
More informationSAT SELECT ENTRY SYSTEMS. User / Installer Guide. Dec 08 SAT3 SAT3/D
SAT3 USER / INSTALLER GUIDE SAT 3 SELECT ENTRY SYSTEMS User / Installer Guide Dec 08 SAT3 SAT3/D SAT3 USER / INSTALLER GUIDE V1.X S elf Identifying A utomatic T elephone 3 & 3/D Select Engineered Systems,
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314
Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More informationColor profile: Disabled Composite Default screen Front Cover I:...JRT2001 Map OM.vp Mon Jun 28 16:22:
Front Cover Contents Introduction...2 Features...2 Included with Your JRT 2001 Phone...3 Controls and Functions....4 Installation...5 Charging the Battery Pack...5 Charging the Handset...5 Low Battery
More informationsmartentry Wireless Video Doorphone User Manual
smartentry Wireless Video Doorphone User Manual Designed & Engineered Version 1.2 in the United Kingdom Contents Precautions... 3 1. Product Overview... 4 1.1. Product Features... 4 1.2. Contents... 4
More informationUP200-GSM Intercom and access control unit operating on mobile GSM network
UP200-GSM Intercom and access control unit operating on mobile GSM network INTRODUCTION The UP200-GSM is an intercom unit which as a cell phone can call the owner s mobile or landline phone. By pressing
More informationInstallation Instructions Model PSC-17C
Installation Instructions Model PSC-17C 17 Amp Power Supply INTRODUCTION The Model PSC-17C from Siemens Industry, Inc. is a high current power supply that provides the Fire Alarm system (Sprachalarmsystem
More informationDocking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.
Docking station Order no. 2883.. Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by qualified electricians. Always follow the relevant
More informationFixed Wireless Phone. User Manual
Fixed Wireless Phone User Manual V1.0 Content 1. Introduction... 1 2. Important Information... 2 3. Dos & Don ts... 2 4. Views... 4 5 Key board Introduction... 4 6. Installation... 5 6.1 SIM card installation...
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationVoice Fax. User Manual
Copyright 2007 UAB Teltonika. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission of UAB
More informationANT CNTR DC ALRM LNB RX DC ALRM +18V OFF
Instruction Manual Model 2082-1972 Power Supply July 2012, Rev. B MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V
More informationEntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation
The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because
More information2 in 1 LAN Tester and Multimeter Model:
2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured
More informationSERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE. EQUIPPED WITH SPK1.
WPP-531-X-ADA-STROBE(LP3P)-SPK1.07UNVLr3-ISSUE4.0 SERVICE MANUAL FOR MODEL WPP-531-X-ADA-STROBE WEATHERPROOF TELEPHONE WITH OPTIONAL STROBE FEATURE EQUIPPED WITH SPK1.07UNVLr3 FIRMWARE Serving the Telephone
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationAlcatel DECT 209 Wireless PBX System
Alcatel DECT 209 Wireless PBX System USER GUIDE 1 User Guide Index Contents 4 Installation 5 The Base 5 The Handset 6 Charger 6 Battery Cover 7 Handset Keys 7 LCD Icons 8 Standby Mode 8 Receiving a Call
More informationPro-Star AVW200 Installation and Operation Manual Protel, Inc. ALL RIGHTS RESERVED AVW200HM01.1
Pro-Star AVW200 Installation and Operation Manual 2005 Protel, Inc. ALL RIGHTS RESERVED AVW200 Installation and Operation Manual Revision History Revision Date Description of Changes AVW200HM01.0 12/05
More informationInstallation & User Manual For Cell Box Switch. GSM Cellular Gate opener and GSM alarm signalling device.
Installation & User Manual For Cell Box Switch GSM Cellular Gate opener and GSM alarm signalling device. P a g e 1 Contents Overview of system.pg 3 Site Survey.Pg 3 SIM card.pg 3 Power.Pg 3 Inserting the
More informationInnoMedia ipbx-400. Quick Install Guide.
InnoMedia ipbx-400 Quick Install Guide www.innomedia.com Table of Contents Introduction 2 Package Contents 2 Installation 3 Wall-Mounting Instructions 5 Troubleshooting 6 Appendix A. LED Status Summary
More information