Installation Instructions Model RNI
|
|
- Osborn Heath
- 5 years ago
- Views:
Transcription
1 Installation Instructions Model Remote Network Interface INTRODUCTION The IEMEN Model allows for the remote installation of the PMI-REM, D-C-REM (on HNET) and the LCM-/CM-/FCM-/IM-/OCM- (on CAN) modules. The HNET can be wired either tyle or tyle. The CAN network may only be wired tyle. The may be placed in the middle or at the end of either the HNET or CAN networks. A VDC input is also required. This can be obtained from the PC- power limited output (TB) or any UL/ULC regulated, power limited power supply listed for fire protective signaling use. The mounts in the rear of either the REMBOX or REMBOX enclosures. The provides terminal blocks for all field wiring connections. Internal connections are made to plug in connectors specifically provided for each of the installed modules. The HNET and the CAN networks can be used simultaneously. TB TB TB TB P OFF TB ON P P P P P X H V Figure Remote Network Interface JP P TB PRE-INTALLATION P enables or disables an audible device similar to the CB. This audible sounds whenever a switch is pressed on either the CM- or the FCM-. If this is not desired the audible can be silenced by changing the jumper installed on P to positions and. P is configured in the factory (positions and ) to have the audible active. is used to terminate the HNET. If the is installed at the end of an HNET network must be set to the ON position. If the is in the middle of the HNET set to the OFF position. P must be set to the HNET (H) position. P/N -- iemens Building Tec echnologies
2 INTALLATION Disconnect BATTERY and AC prior to working on equipment. The mounts on studs in the rear of either the REMBOX or the REMBOX. Four #/ nuts are provided with the. (Refer to the REMBOX/REMBOX Installation Instructions, P/N -.) Install the with the terminal blocks facing up to allow for easier connection of the field wiring. Connecting The PMI-REM A inch long wire cable, P/N - (shipped with the PMI-REM), connects the to the PMI-REM. Connect one end of the cable to JP on the and the other end of the cable to JP on the PMI-REM. Be sure that the PMI-REM address agrees with the ZEU configuration. Refer to the PMI-REM Installation Insturctions, P/N -.. AWG min.. A max. input current.. upervised. Refer to PC-/PX- Installation Instructions, P/N - for connection to TB. TO PC- TB OR ANY UL/ULC REGULATED, POWER LIMITED POWER UPPLY LITED FOR FIRE PROTECTIVE IGNALING UE Figure Connecting The VDC Input + TB + V B+ NIC-C B A+ A. No EOLR required.. AWG min., AWG max.. ohms max. per pair.. Use twisted pair or twisted. Power limited to NFPA per NEC.. Refer to NIC-C Installation Instructions, P/N - for connection of A and B pairs.. Omit B pair for tyle.. All wiring supervised. PRE DOWN Figure Connecting HNET At The End Of The Network (tyle and tyle ) A A+ ET TO ON B B+ TB iemens Building Technologies P/N --
3 NIC-C OR B+ B+ B B A+ A+ A A TO NEXT NIC-C OR. No EOLR required.. AWG min., AWG max.. ohms max. per pair.. Use twisted pair or twisted. Power limited to NFPA per NEC.. Refer to NIC-C Installation Instructions, P/N - for connection of A and B pairs.. Omit B pair for tyle.. All wiring supervised. PUH UP A Figure Connecting HNET In The Middle Of The Network (tyle and tyle ) A+ ET TO OFF B B+ TB PC- TB CAN CAN + DO NOT UE TB. AWG min., AWG max.. ohms max. for CAN network.. Use twisted pair or twisted. Power limited to NFPA per NEC.. Refer to NIC-C Installation Instructions, P/N - for connection of CAN, CAN+.. Only CM- shown. CM-, LCM-, FCM-, OCM-, IM- all allowed.. All field wiring supervised. DO NOT UE P P Figure Connecting CAN At The End Of The Network CCL (UPPLIED WITH THE ) MOUNT TO ID-MP ON INNER DOOR OF REMBOX/ LCM- OR CM- INTALL CAN TERMINATOR P/N - (HIPPED WITH NIC-C) iemens Building Technologies P/N --
4 PC- TB CAN CAN + CAN + CAN TO NEXT TB. AWG min., AWG max.. ohms max. for CAN network.. Use twisted pair or twisted. Power limited to NFPA per NEC.. Refer to NIC-C Installation Instructions, P/N - for connection of CAN, CAN+.. Only CM- shown. CM-, LCM-, FCM-, OCM-, IM- all allowed.. All field wiring supervised. P P CCL* CCL* *ONLY CCL, P/N - I UPPLIED WITH THE LCM- OR CM- MOUNT TO ID-MP ON INNER DOOR OF REMBOX/ Figure Connecting CAN In The Middle Of The Network Connecting The Optional HTW- Tamper witch Connect the HTW- (required for UL) to P on the using the connector supplied with HTW-. Refer to the REMBOX Installation Instructions, P/N - and the HTW- Installation Instructions, P/N -. Connecting The LCM/CM/FCM Mount the LCM/CM/FCM to the ID-MP (Refer to the LCM/CM/FCM Installation Instructions, P/N -). Mount the ID-MP to the inner door of the REMBOX/. Connecting The D-C-REM Mount the D-C-REM to the inner door of the REMBOX/. Using the -wire cable supplied with the D-C-REM, connect the D-C-REM to P on the. iemens Building Technologies P/N --
5 POT-INTALLATION Before applying power to the check the following: Ensure that the VDC power input on TB is connected and that the polarity is correct. Check the setting of. If the is at the end of the HNET is must be set to on. If the is in the middle of the HNET it must be set to off. If the HNET is not used the position of does not matter. Check the position of P. It must be set to H. Check the CAN termination. If the is at the end of the CAN network, a CAN terminator (P/N-, supplied with the NIC-C) must be installed into the last CAN module in the REMBOX. If the is in the middle of the CAN network no CAN terminators can be installed. If CAN is not used then the terminator can be stored in P. It will be needed if CAN modules are added to the REMBOX at a later time. Refer to the NIC-C Installation Instructions P/N - for examples of CAN installation and termination. Check the setting of P. If the local sound is required, make sure P is set to ON. Otherwise, set it to OFF. COMPATIBILITY The is compatible with the FireFinder XL HNET and CAN networks only. The can not be used with the MXL MNET. ELECTRICAL RATING V Back Plane Current ma Max. * crew Terminal V Current.V Back Plane Current V tandby Current ma Max. * * current only. Be sure to include the VDC screw terminal current for all other HNET and CAN modules when performing power supply loading calculations or battery calculations. iemens Building Technologies P/N --
6 For CE applications in Cerberus E systems refer to Installation Instruction A-A-B (English) or A-A-A (German). iemens Building Technologies, Inc. Fernwood Road Florham Park, New Jersey iemens Building Technologies, Ltd. iemens Gebäudesicherheit Kenview Boulevard GmbH & Co. ohg Brampton, Ontario LT E CN D- München P/N --
Installation Instructions Models FCM-6 / LCM-8 / SCM-8 Model CSB
Installation Instructions Models FCM- / LCM- / SCM- Model CSB Control Module / LED Control Module / Switch Control Module CAN Sounder Board INTRODUCTION The Models FCM-, LCM- and SCM- from, are similar
More informationInstallation Instructions Model PSX-12
Installation Instructions Model PSX- Amp Power Supply Extender INTRODUCTI The SIEMENS Model PSX- is a high current power supply extender. The power supply extender works in conjunction with the PSC- power
More informationInstallation Instructions Models CC-5 / CC-2
Installation Instructions Models CC-5 / CC-2 System Cardcage CC-5 (500-633037 / S24235-B123-A1) System Cardcage CC-2 (500-633440 / S24235-B122-A1) INTRODUCTION The SIEMENS Model CC-5 Cardcage (see Figure
More informationInstallation Instructions Model FMT
Installation Instructions Model FMT Fireman s Master Telephone ITRODUCTI The Model FMT Fireman s Master Telephone from Siemens Industry, Inc. provides firefighters with an emergency telephone system for
More informationInstallation Instructions Model SNC Serial Network Card for USB Application with Windows
Installation Instructions Model SNC Serial Network Card for USB Application with Windows OPERATION The Model SNC from Siemens Industry, Inc. (as shown in Figure 1) is a USB-compliant network card used
More informationInstallation Instructions Model NIC-C
nstallation nstructions Model Network nterface Card NTRODUCTON The Model from, is a card that provides HNET/XNET and CAN network communication within and between enclosures. The HNET/XNET network can be
More informationInstallation Instructions Model LPB
Installation Instructions Model LPB Local Page Board (500-035200 / S24235-B5-A2) INTRODUCTION The LPB (Local Page Board) is used to connect the alarm microphone, mounted in the LVM (Live Voice Microphone),
More informationCAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM, OD-LP, OD-BP, OD-GP, REMBOX2, REMBOX4, XLS-MLE6-ADPT,
Data Sheet Fire Safety & Security Products s FireFinder TM XLS Fire Alarm Enclosures & Equipment Models: CAB1, CAB-BATT, CAB-BATT-R, CAB2-BB, CAB2-BD, CAB3-BB, CAB3-BD, CAB-MP, ID-MP, ID-SP, ID-FP, BCM,
More informationFire Safety. Installation Instructions. Models PIM-2/PAL-1 Peripheral Interface Module 2/Parallel Printer OPERATION INSTALLATION
Fire Safety Installation Instructions Models PIM-2/PAL-1 Peripheral Interface Module 2/Parallel Printer OPERATI The SIEMES Model PIM-2 module is an interface that allows the connection of UL listed EDP
More informationInstallation Instructions
Installation Instructions Model PAL- Parallel Printer Operation The model PAL- from Siemens Industry, Inc. allows the connection of an ITE Centronics parallel printer to the Siemens FireFinder- XLS, MXL,
More informationInstallation Instructions Model PSC-17C
Installation Instructions Model PSC-17C 17 Amp Power Supply INTRODUCTION The Model PSC-17C from Siemens Industry, Inc. is a high current power supply that provides the Fire Alarm system (Sprachalarmsystem
More informationINSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches)
INSTALLATION INSTRUCTIONS Model VTO2001-U2/U3 Option Module (24 Switches) The Model VTO2001-U2/U3 Option Module (24 Switches) illustrated in Figure 1 is installed in the FV2025/2050 Fire Voice Control
More informationAPPENDIX FOR AccuLINK (CSG-M) Revision 17.01
Fire Safety APPENDIX FOR AccuLINK (CSG-M) Revision 17.01 Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 07932 Siemens Building Technologies, Ltd. 2 Kenview Boulevard Brampton,
More informationCerberus Division. Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL. (Remote Diagnostics Module)
Cerberus Division Installation Instructions CERBERUS PYROTRONICS TM Model RDM-MXL Remote Diagnostics Module INTRODUCTION The CERBERUS PYROTRONICS TM Model RDM-MXL module (RDM for connection to the MXL
More informationInstallation Instructions & Users Manual
TATU CENTRAL BATTERY YTEM AUTOMATIC DIAGNOTIC NORMAL FULL CHARGE NORMAL FAT RECHARGE FAILED BATTERY FAILED TRANFER FAILED CHARGER PAED ANNUAL TET LED DIPLAY ORANGE RED RED PAUE ORANGE FLAH RED FLAH RED/
More informationMXL/MXLV 19 Rack Mount Fire Alarm Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3
MXL/MXLV 19 Rack Mount Fire Alarm Equipment Models: MXL-RK1, ACM-RK, MKB-RK, MMB-RK, MOM-RK, MPS-RK, TSP-RK, VSM-RK, CABLES-RK, MKB-3 Standard 19 Rack Mounting for MXL and MXLV System Modules Rack Mount
More informationMXL / MXLV Enclosures & Equipment
s Data Sheet Fire Safety & Security Products MXL / MXLV Enclosures & Equipment Models: MME-3, MBR-MP,, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4u ARCHITECT AND ENGINEER SPECIFICATIONS MME-3
More informationInstallation Instructions Model ZAM-180
s Installation Instructions Model ZAM-80 Zone Amplifier Module 80W (500-035600 / S24235-B6-A5 (70V)) Installation Instructions for North America INTRODUCTION The Model ZAM-80 from Siemens Industry, Inc.
More informationEA500. Installation Instructions Transponder
EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the
More informationMXL / MXLV Rack-Mount Fire-Alarm Equipment
s Data Sheet Fire Safety & Security Products MXL / MXLV Rack-Mount Fire-Alarm Equipment Models: ACM-RK, CABLES-RK, MKB-3, MKB-RK, MMB-RK, MOM-RK, MPS-RK, MXL-RK1, TSP-RK, and VSM-RK ARCHITECT AND ENGINEER
More informationINSTALLATION INSTRUCTIONS Model VCC2002-A1 Voice input/output Card
INSTALLATION INSTRUCTIONS Model VCC2002-A Voice input/output Card The Model VCC2002-A Voice I/O card is installed into the FV2025/2050 Fire Voice Control Panel of the FS20 system. Together with the VCC200-A
More informationThe Model Scalance X204-2 Multimode and X204--2LD Single
Installation Instructions Model Scalance X204-2 Multimode and X204-2LD Single Mode Ethernet Fiber Switch Fiber Switch Ethernet Connections TRODUCTION The Model Scalance X204-2 Multimode and X204--2LD Single
More information1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN
More informationNFS NFS-3030 NFS2-640 NFS-640 NFS-320 NCA NCA-2 DVC-EM ONYXWorks
12 Clintonville Road Northford, CT 06472-1610 USA 203-484-7161 FAX 203-484-7118 www.notifier.com High-Speed Network Communications Module Product Installation Document 1 Product Overview PN 54014:B 11/17/2009
More informationFireFinder. (NCCXP/W7-G/-GL and NCCXP/W7WAN Version 7.81) and Maintenanc. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ
FireFinder Net etwor ork Command Cent enter er Graphics (NCCXP/W7-G/-GL and NCCXP/W7WAN Version 7.81) Operat ation, Installat allation, and Maintenanc enance e Manual Siemens Industry, Inc. Building Technologies
More informationEP-ELVCTL Elevator Control (NION-16C48M)
EP-ELVCTL Elevator Control (NION-16C48M) Product Installation Document This document covers the procedures and specifications for installing the above listed unit and when appropriate, information regarding
More informationAirTest Model CN9000 Series Sensor Controller
AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay
More informationInstallation Instructions Model NCCXP-UK
Installation Instructions Model NCCXP-UK Upgrade Kit For The Network Command Center Using Windows XP Software Installation All SBT, Inc. computers are preloaded with the NCCG software. Follow the procedure
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationMAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS
MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.
More informationTB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.
NXT x.0 Wiring and Layout Diagrams. NXT-x I/O Module Shielded CAT- Cabling Shielded -Conductor Cabling total cable length 00 feet max (0 m) Brown/Green/Orange w/o Stripe Brown/Green/Orange with Stripe
More informationMS-7000: SuperStar Reader
The MS-7000 SuperStar Reader The MS-7000 SuperStar Reader is intended for installation in proximity applications where an extended read range is required. The reader provides an audio beeper and a multi
More informationThe Exp-007 unit connects directly to Remote Status Indicator units to provide 2 programmable 1-Amp rated, volt free, clean contact outputs.
Relay Outputs The Exp-007 and Exp-008 are internal peripherals for use with the Ex3000 gas extinguishing system. The units are used to expand the number of outputs available on the system either local
More informationMS-3000 MicroStar Reader
MicroStar Reader The MicroStar Reader The MicroStar Reader is intended for installation on a window mullion or a door frame, on or off metal, in proximity applications where an unobtrusive reader is required.
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More information900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note
*44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs
More informationPagePac PAGEPAC PLUS ZONE EXPANSION UNIT V
PagePac Issue 3 by PAGEPAC PLUS ZONE EXPANSION UNIT V-5335100 INTRODUCTION The Zone Expansion Unit (ZEU) provides up to 16 zones of audio output (including talkback), contact closure outputs or inputs.
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationBeacon Power Management System Installation Manual
Beacon Power Management System Installation Manual Model Numbers: BN4-000-PD8F-UL 10003 BN4-000-PD8-UL 10002 BN4-002-PD8F-UL 10006 BN4-002-PD8-UL 10005 BN6-000-PD8F-UL 10015 BN6-000-PD8-UL 10014 BN6-002-PD8F-UL
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationFire Safety. Installation Instructions Model ACM-1 Audio Control Module INTRODUCTION OPERATIONS
Fire Safety Installation Instructions Model ACM-1 Audio Control Module INTRODUCTION The SIEMENS Model ACM-1 Audio Control module is the master control module for the MXLV audio system. The module controls
More informationMODEL FPI-32 PROGRAMMER/TESTER Operations Manual
MODEL FPI-32 PROGRAMMER/TESTER Operations Manual Siemens Industry, Inc. Building Technologies Division Florham Park, NJ P/N 315-090077-10 Siemens Building Technologies, Ltd. Fire Safety & Security Products
More informationNFS NFS-3030 NFS2-640 NFS-640 NFS-320 NCA NCA-2 DVC-EM ONYXWorks
12 Clintonville Road Northford, CT 06472-1610 USA 203-484-7161 FAX 203-484-7118 www.notifier.com High-Speed Network Communications Module Product Installation Document 1 Product Overview PN 54014:B2 04/25/2014
More informationMS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications
The MiniStar Reader The MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also be mounted directly
More informationThermometer / Barometer System
TBX USER S MANUAL Thermometer / Barometer System 616TA Pg.2of12 TABLE OF CONTENTS QUICK START GUIDE... 3 INTRODUCTION... 6 SPECIFICATIONS... 6 TERMINAL COMPARTMENT LAYOUT... 7 FEATURES... 8 OPERATION...
More informationand Network Interface Modules Installation Instructions
4010-9817 and 4010-9821 Network Interface Modules Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationSIGA-CC1/CC2 Signal Modules SIGA-MCC1/MCC2 Signal Modules
SIGA-CC/CC Signal Modules SIGA-MCC/MCC Signal Modules FEATURES SPECIFICATION DATA Single and Dual Signal Switching. Ring-Tone Generator. Non-volatile Memory. Integral Microprocessor. High Ambient Temperature
More informationAllen-Bradley 1397 AC Tachometer Interface Card
Instructions Allen-Bradley 1397 AC Tachometer Interface Card Cat. No. 1397-AC Contents Topic Page What This Option Provides 1 Where This Option Is Used 1 What These Instructions Contain 1 Specifications
More informationAllen-Bradley 1397 L11 I/O Expansion Card
Installation Instructions IN Allen-Bradley 1397 L11 Expansion Card Cat. No. 1397-L11 What This Option Provides The Expansion Card is a drive mounted board that provides these additional signals. (5) Digital
More informationBeacon Power Supply Operating and Installation Instruction Manual
Beacon Power Supply Operating and Installation Instruction Manual Model: BNx000 Page 1 of 27 I. Warnings and Notices I. WARNING - To reduce the risk of fire or electric shock, do not expose this product
More informationTruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationMS-4000: ShootingStar Reader
: ShootingStar Reader The ShootingStar Reader The ShootingStar Reader is intended for installation on a solid metal surface, in proximity applications where a vandal-proof reader is required. The reader
More informationTraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE
TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions
More informationOPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES
PRICE: $25.00 LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES www.unipowertelecom.com Manual No. LVD-201-2 8/29/01/L46Man 2001 UNIPOWER Corp. All Rights Reserved UNIPOWER Telecom, Division of UNIPOWER
More informationINSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage
INSTALLATION INSTRUCTIONS Model VCA2002-A1 Card Cage The Model VCA2002-A1 Card Cage assembly is installed in the FV2025/2050, FV922/FV924 Fire Voice Control Panel of the FS20 system to house and interconnect
More informationQuick Start Guide. SEB-710 I/O Expansion board. Introduction
SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More information4100/4120-Series Class A / Class B Zone Modules Installation Instructions
4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box
More informationCisco ONS CL Shelf Assembly Hardware
CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.
More informationMeasure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.
Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,
More informationSecured Series: Hub Plus Kit Single Door Controller Package Installation Manual
Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into
More informationSPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS
SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors
More informationCardkey S300 Enclosures
Cardkey S300 Enclosures Product Bulletin Code No. LIT-12011184 Issued March 13, 2007 Supersedes April 10, 2006 Introduction Johnson Controls S300 enclosures provide a secure tamper-resistant housing for
More informationBA/BS4S Temperature Sensor Installation & Operating Instructions
Product Overview and Identification The BAPI-Stat 4 room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication jack.
More informationSpecifications, Installation, and Operating Instructions
Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.
More informationCU-8R Installation Instructions
CU-8R Installation Instructions I. Components Model CU-8R is shipped with the following components: QTY Item 1 Stainless Steel Enclosure 2 Lexan Panels 18 Nuts 1 Wall Mount Style Phone with RJ-11 Cable
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More informationDESIGN GUIDE FOR INFINITY SYSTEMS
Doc. 6001564 Rev B DESIGN GUIDE FOR INFINITY SYSTEMS WITH STAND ALONE OR MULTI-LINK LINK FIRMWARE TABLE OF CONTENTS 1. CABINET DIMENSIONS...3 2. WIRE CHART...3 A. CABLING TO THE MAIN PROCESSOR BOARD...
More informationICP-SDI Installation Instructions. SDI Splitter
ICP-SDI-9114 EN Installation Instructions SDI Splitter ICP-SDI-9114 Installation Instructions Listings and Approvals Listings and Approvals UL UL 65 Police Station Burglar Alarm Units and Systems UL 609
More informationIntroduction. General Ratings
Introduction Storage temperature Operating temperature Humidity Weight Dimensions Screw terminal wire gauge Supply voltage Supply currents Maximum baud rate Unit Mounting Housing o -20 to +70 C o Allows
More informationCTR21, CTR22, CTR23, and CTR24 Wall Modules
CTR21, CTR22, CTR23, and CTR24 Wall Modules FEATURES SPECIFICATION DATA The CTR21, CTR22, CTR23, and CTR24 family of wall modules include: Models with setpoint adjustment. Models with occupied/unoccupied
More informationMLA-1 / MLA-10 Installation/Operations Manual
Table of Contents Introduction 1 MLA-1 vs. MLA-10 Comparison 3 MLA-10 Details 4 MLA-1 Details 6 Special Interest Notes 8 1 INTRODUCTION This is the preliminary manual covering the installation and operation
More informationADDENDUM FOR 20, 27, & 28 OPTIONS
ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and
More informationMODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT
MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state
More informationMR52 READER INTERFACE
IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This
More informationrdczbk User Manual ZigBee to RS-232 / RS-485 Converter
1. Product Overview rdczbk User Manual ZigBee to RS-232 / RS-485 Converter Robust DataComm Pte Ltd The rdczbk is basically a XBee / XBee Pro carrier board that provides either RS-485 or RS-232 connectivity
More informationInstallation Instructions
Installation Instructions Doorphone Card Model KX-TD161 Please read this manual before installing the card. Thank you for purchasing the Card. Doorphone Card Supports 4 doorphones and 4 door openers. The
More informationAudio Input Card Installation Instructions
Installation Instructions Introduction This publication describes the installation procedure for the 4100-1240. This card is compatible with 4100U and 4100ES Fire Alarm Control Panels. In this Publication
More informationAVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL
AVC 2 AUTOMATIC VOLUME CONTROL USERS MANUAL GENERAL DETAIL The AVC2 will control a stereo channel to a preset maximum output level allowing the maximum sound level of a system to be controlled. The AVC2
More informationTAC I/NETTM 1284, 1280, Security Control Unit
TAC I/NETTM The SCU () family of modular, stand-alone controllers are basic building blocks of the I/NET Seven Security Management System, and provide a flexible mix of door control and alarm monitoring
More informationMXLV Multiplex Emergency Voice Alarm / Communication System
s Data Sheet Fire Safety & Security Products MXLV Multiplex Emergency Voice Alarm / Communication System Switched multiplex audio and firefighters telephones Modular design 25 or 70.7 VRMS audio signals
More informationB100 Installation Manual
Installation Manual Description The provides an additional voltage in a FlexPower system. This voltage can either be accessed directly via the 's terminals or through other FlexPower Accessory Boards.
More informationMS-5000: MiniStar Reader
The MS-5000 MiniStar Reader The MS-5000 MiniStar Reader is intended for installation in a single gang electrical "J-Box," in proximity applications where an unobtrusive reader is required. It can also
More informationInstallation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2
Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3
More informationZero Volt Monitor Installation, Operation and Maintenance
TECHNICAL BULLETIN TB-6515 Zero Volt Monitor Installation, Operation and Maintenance Made in the United States of America strap properly, the monitor measures the loop resistance consisting of one wire
More informationVG-305A AC Traffic Light Controller Kit
Galak Electronics Electronic kits and components Website: GalakElectronics.com Email: sales@galakelectronics.com Phone: (302) 832-1978 VG-305A AC Traffic Light Controller Kit Thank you for your purchase
More informationAlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)
AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s) APPLICATION The AlphaStatus system allows one or more RSS402, RSS403,
More informationVS-616PC5/P5 Option Instruction Manual
VS-66PC5/P5 Option Instruction Manual Isolated 4-20mA Output Monitor Card PRECAUTIONS! DANGER. Read this instruction manual in its entirety before installing the Isolated Monitor Card or operating the
More informationistar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More informationInfinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output
GE Critical Power Quick Start Guide Infinity 1U 19 Converter Shelf Models: J5964803 L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output Edge Controller This shelf
More informationELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085
ELECTRONIC CONTROLS & SENSORS AK-SC255 Fact Sheet Version R Software Software version 02_085 What s in the Box? 1x AK-SC255 (either Box or DIN rail screen-less version) What are the different part numbers?
More informationAdvanced Visual Solutions Ltd
Advanced Visual Solutions Ltd Unit 2, Eastman Way Hemel Hempstead, Hertfordshire HP2 7DU Telephone : ( 01442 ) 252280 Fax : ( 01442 ) 244578 Email : visionservices@btclick.com : Website : www.avsl.com
More informationGE Contactless Reader Models 240/245/250 Installation Guide
GE Contactless Reader Models 240/245/250 Installation Guide GE Security, Inc. 791 Park of Commerce Boulevard Suite 100 Boca Raton, Florida 33487 (561) 998-6100 Part Number: 460563001C February, 2004 This
More informationGLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF
Power Supplies GL Series: Single & Multi Output Switchers The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500 watts for use in various
More informationHD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL
DVS772HD HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL IB6445-01 DESCRIPTION The DVS772HD high definition DIGITAL VIDEO SWITCH is a high isolation high frequency relay used to switch digital signals
More informationPower Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF
3 Power Supplies GL Series: Single & Multi Output Switchers The new GL series provides a broad range of AC/DC power supply solutions that covers power ratings from 25 watts to 500 watts for use in various
More information4100/4120-Series and 4010ES Relay Modules Installation Instructions
4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description
More informationControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet
General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.
More informationHOUSING DEVICES, INC. HDI ADA - ARCU. Installation & Operations Manual. Made in the USA
HOUSING DEVICES, INC. ADA - ARCU Installation & Operations Manual Made in the USA ADA - ARCU 5 & 10 Pre-Installation Requirements: For each ADA-1000 in the elevator you must run a twisted, shielded, 22