Application. Meassuring. Processing. Store. DuoSens

Size: px
Start display at page:

Download "Application. Meassuring. Processing. Store. DuoSens"

Transcription

1 Application DuoSens Meassuring Processing Store

2 Application DuoSens Tranamission via SMS /GPRS Alarm via SMS Transmission via satellite

3 General Features DuoSens - RS232 - Relay - Voltage Switch Display Jog-shuttle Optical interface (IrDA) - Voltage input - Current input - RS232 (e.g. Nimbus) - RS485 (e,g Kalesto) - Pulse input (e.g. Rainguage) - SDI 12 (e.g. Hydrolab probes)

4

5 netdl500 / netdl 1000

6 Chapter 1: Introduction Chapter 2: Communication with DuoSens Chapter 3: Set up Time & Date, Password, Delete Memory Chapter 4: Program, Write, Export / Read, Load, Import Configuration Chapter 5: New Configurations Explanation of structure

7 Chapter 6: Communication interface Chapter 7: Alarm Management Chapter 8: GPRS Settings Chapter 9: Channel Configuration (Sensors!) Chapter 10: Print Configuration Chapter 11: New Program Code (Firmware) Chapter 12: Terminal Mode (for advanced users)

8 1 - Introduction Short description DuoSens: Highly configurable data logger SDI, Impulse and Analogue input channels, 1 output channel, 4 MB ring buffer, jog shuttle, Configuration Program: DuoSens, DuoSens 2, DuoSens Explanation of functionality Showing an example Exercise and solution Hints Practise

9 2 Communication with DuoSens Choose right COM Port, Speed: Auto For on site communication the IrDA with OTT DuoLink is recommended, sometimes RS232C is used. For remote communication choose AT-Modem/Adapter Press desired function (next chapter). For Modem/ISDN type in number (plus pre-dialling string) and e. g. for ELSA Microlink 56 k initialisation string.

10 2 Communication with DuoSens Check date and time of DuoSens via direct communication (IrDA) and via modem (GSM): 1. Choose IrDA OTT Duolink, choose COM Port 1, Speed: Auto, Choose DuoSens/ Date & Time After checking the date click on Cancel to exit the date & time area. Then click on Exit to stop communication (especially on remote parameterization via Modem or ISDN).. 2. Choose AT-Modem/Adapter, choose COM Port 1, Speed: Auto, Choose DuoSens/ Date & Time, type in telephone number, no pre-dialling string, check Hayes compatible

11 3 - Time & Date, Password, Delete Memory All Functions for DuoSens operations are listed under menu DuoSens Read configuration from DuoSens Program configuration to DuoSens Check and set date / time Delete data memory Enter Terminal mode for all functions (for advanced users) Enter password (access only to authorised persons) New firmware for DuoSens (new functions etc)

12 3 - Time & Date, Password, Delete Memory If password is set for DuoSens, type in the password! If not, redo this exercise after reading chapter 6. Set actual date & time via OTT DuoLink. Now delete memory. Normally setting the date & time means synchronizing PC time with DuoSens time (compare!), so check your PC time first. You can set the DuoSens to any date and time by changing the suggestion. Press Refresh to see the actual time of DuoSens. Best solution is to run DuoSens on local winter time (no change in summer)! Keep your password secure! Before deleting memory, load data from DuoSens! You have to delete memory after new installation, significant change in configuration or in case of fault.

13 4 - Program, Write, Export / Read, Load, Import 3 types of handling configurations: Read from and program to DuoSens. Remember menu DuoSens. Load from and save to internal database. See also menu Configurations. Import from and export to bin-file. Only menu File. Export to station details to Hydras3

14 4 - Program, Write, Export / Read, Load, Import Set up communication to DuoSens. Read configuration from DuoSens. Then program configuration back to DuoSens, write configuration in internal database and export configuration to external file (e. g. c:\programs\ott\logocnf\files\test.bin). Now load configuration from internal database and import configuration from external file (see above). Before programming a new configuration to DuoSens first read configuration and export it with name old.bin. Actual configuration should be stored in internal database. If someone needs your configuration, export it to filename act.bin and transfer your file to the network (or just save it to disk). Then the user can import it to use it e. g. for another DuoSens.

15 5 - New Configurations Explanation of structure Choose menu file / new configuration. Right beside the tree structure you see the general information of the DuoSens: number, name and time zone (all can be altered). Below date and time of last download of configuration and parameters are listed. The version number (of firmware) is shown only after new reading of configuration. With the tree structure any parameter of DuoSens can be accessed: communication interface, alarm management, channel definition.

16 5 - New Configurations Explanation of structure Read configuration from DuoSens. Check download time and version number. Save configuration to internal database. To ensure that you don t write the false configuration to the DuoSens, first read configuration and compare station number. Create new configuration, change number ( ), name ( first test ) and time zone ( -4h, important for satellite communication). Save configuration to internal database. Setting up a password (e. g. last four digits of telephone number) is another possibility to prevent overwriting with wrong configuration (see next page). Program this configuration to DuoSens. Read configuration from DuoSens. Check download time again.

17 6 - Communication interface RS232 interface can be used for modem/adapter, satellite communication (METEOSAT/GOES) and SDI communication (RS232 disabled). Submenus are General, Modem/ Adapter, METEOSAT/GOES, SDI-Slave, SMS-Data (only visible after choosing GSM-Modem with SMS). Baud rate has to be selected for modem/adapter only. Activation control via relay contact is only available for modem/adapter. Data bits, Parity and stop bits are fixed. Address number can be used as password to prevent unauthorized data transfer. Password (max. 8 char: 0-9, A-Z)

18 6 - Communication interface Setting up a modem/terminal adapter: Check Modem connected to RS232C. Type in initialization string (or choose one of presets). Now go back to menu general and choose baud rate (e. g ). To save energy (or for reinitialization purposes) Choose relay contact M 3-4. Set up activation time(s) and duration (for daily initialization use activation time 00:01 and duration of 1438 min.).

19 6 - Communication interface Settings to send SMS (messages and data), fax and (only messages): Check GSM modem with SMS Type in GSM service center phone no. SMS data functionality Special program SMS Receiver needed! Check Transmission SMS Cycle standard: e. g. 6 h Cycle limit event: e. g. 1 h Number of SMS receiver (Base Station) No. of max. following SMS: 1 Check sensors for transmission

20 7 - Alarm Management Alarm will be send on special conditions to address group. Click New to enter new address. Alarm message to mobile phone via SMS: Type in mobile phone no. Choose modem/adapter Choose SMS Choose Text SMS prefix: prefix for SMS text Alarm message to fax and is similar!

21 7 - Alarm Management Alarm message to Hydras 3: Type in phone no. of Hydras 3 computer Choose modem/adapter Choose modem passive Choose OTT protocol standard Choose no. of dealings Choose reading pause (min.) Alarm message to terminal program Type in phone no. Choose modem/adapter Choose modem active Choose protocol type text

22 7 - Alarm Management Alarm with external device (e. g. Bell, Flashing Light): Choose relay switch output Choose M1-2 Choose OTT protocol standard Choose switch time (s), 0 means on/off will last till next variation.

23 7 - Alarm Management Other alarm possibilities: To activate cycle limit for SMS data transfer.

24 7 - Alarm Management Alarm can be sent only to address group: Click on Address groups / New Type in Name Drag & drop address from right to left window To delete address from group: mark address and press del

25 7 - Alarm Management Set up alarm-address with SMS message to your mobile phone. Set up alarm-address for Hydras 3 alert. You can set up different alarm levels (values run over/under specified limits). These can trigger different alarm addresses. So depending on the limit you should send s (uncritical) Set up alarm-address-group with all three addresses.

26 8 GPRS Settings

27 8 GPRS Settings

28 8 GPRS Settings Select your Service Provider ( SIM Card) Automatically assigns Operator fields Passive FTP is recommended (not possible with the edevice modem). If issues occur try active FTP Enter the server Info Server path might be left blank but if defined, it has to exist! Case Sensitive Operator Independant Attention: for server path use / to separate different levels and not the common one from Windows \. See example above!

29 9 - Channel Configuration Any channel with a sensor should consist of Information of channel (number, name, unit and no. of decimal places) Measuring cycle (sampling interval from 5 s to 24 h) Definition for input channel Scaling if desired Instantaneous value (DuoSens will show value in display) Store (value will be stored in memory)

30 Channel Configuration Menu structure for definition of channels: Drag & drop functions to tree structure (will appear below actual position) Create new channel Meas. cycle (interval) Input sensors: Analogue: U, I, Pt100, NTC, Conduc., U DuoSens Input sensors: Digital: Status, Pulse, Freq RainGauge Input sensors: Serial: Kalesto, SDI12, Smart S., HydroSens SPI Scaling, table, storage delta, mean (over time), limits for alarm, mean wind. Store, Instantane ous value, Relay switch output, HydroSens SPI Virtual sensors & terminals,

31 Channel Configuration DuoSens will work through configuration from top to down one channel after the other. Channel will be handled only if measurement cycle is triggered by internal time. Create new configuration. Click on channel. Drag & drop new channel before existing channel. (New channel is now the first one in workflow) Click on meas. cycle, drag & drop meas. cycle internal.

32 Channel Configuration Set number (0001), name ( Water Level 1 ) and unit ( m ) of sensor. Set meas. Cycle to 1 min. Complete new channel with SDI 12 (on terminal block A 3-4 ), scaling, instantaneous value and store. Create another sensor at the end of configuration: Number: 0002 Name: Temperature Unit: C Meas. Cycle: 15 min. Sensor: Virtual Sensor [ V01] Scaling, instantaneous value, store Order of channels can t be changed after definition. Do delete definition, mark row and press del. Channel can t be deleted before all adjacent channelconfigurations are deleted.

33 Channel Configuration Virtual sensor and virtual terminal (V1 to V64) Allows a very wide variety of functionality: Some sensors apply values to normal sensor and to virtual sensor Access to virtual sensors is very fast (normal sensors delay program: meas. time). Allow complex calculations. Duplicate Sensors for output in different units (m and feet). Complex limit definitions. First apply value (actual value in channel) to virtual terminal. Now value can be accessed with virtual sensor.

34 Channel Configuration Mean arithmetic (4x) Sum, difference and mean of up to 4 values You have to define virtual sensors for input first. Output is set to actual value in channel and can be applied to virtual terminal. Mode can be set to ( ) / n (n is number of valid virtual sensors)

35 Channel Configuration Mean (in time domain) Mean interval should be multiple of measuring interval (3 min. > 6, 9, 12,15 min.). Can be used for highly altering values and to save memory: Set meas. cycle to 1 min. Set mean to 15 min. (1 good value) Values will be stored with 15 min. interval.

36 Channel Configuration Limit / threshold is used to trigger alarm (message) and higher cycle for SMS data transmission. Value is compared with limit: If limit is reached, alarm will be triggerd. Hysteresis: change of value before new alarm is generated. Tolerance: How many times must value reach limit. Gradient; Value increases or decreases with specified gradient. After dead time new alarm is generated. Operating area: Gradient limit control will only be active when values are in operating area.

37 Channel Configuration Scaling Scaling y=ax+b: used to define offset and transformation between units. Also used if you want to set value manually. 2 point scaling: see above; especially used to transform electrical signal to meteorological/hydrological value. Linearization table: This can be used to correct nonlinear sensor or to define area as function of water level. Tables can be saved and loaded from disk.

38 Channel Configuration Storing and Output Storage delta (submenu processing): useful for precipitation; will filter data if there is no change in value, store is still needed. Store: Values are stored in memory. Relay function M 3-4: switch on or off for specified seconds. Former status will be lost, hard on/off..

39 Channel Configuration Now try to write your own configurations. Play around with functionality. Try different sensors. Set up alarms

40 9 - Print Configuration Menu for printing connection diagram and configuration is found under file / print Connection diagram makes it easier to connect sensors with correct wiring.

41 9 - Print Configuration Configuration in DuoSens operating program can t be seen with all details at once (you have to click on any row to see the details). But you can export configuration in file (which can be printed) in two formats (examples of the configuration on right is shown on next page).

42 9 - Print Configuration Configuration can be printed as normal textfile (see right) or as XML-file (see below, tags shown with MS Internet Explorer). <STATION> <DEVICETYPE>OTT DUOSENS</DEVICETYPE> <STATIONID> </STATIONID> <STATIONNAME>OPW DuoSens Template Program</STATIONNAME> <STATIONUTC>+00:00</STATIONUTC> <STATIONPHONENO1> </STATIONPHONENO1> <SENSOR> <SENSORID>0001</SENSORID> <SENSORNAME>Waterlevel</SENSORNAME> <UNIT>m</UNIT> <RIGHTDIGITS>3</RIGHTDIGITS> <AXISLABEL>Waterlevel</AXISLABEL> <INTERVAL>9000</INTERVAL> </SENSOR> <SENSOR> <SENSORID>0002</SENSORID> <SENSORNAME>Watertemp.</SENSORNAME> <UNIT> C</UNIT> <RIGHTDIGITS>1</RIGHTDIGITS> <AXISLABEL>Watertemp.</AXISLABEL> <INTERVAL>36000</INTERVAL> </SENSOR> <SENSOR> <SENSORID>0003</SENSORID> <SENSORNAME>Voltage</SENSORNAME> <UNIT>Volt</UNIT> <RIGHTDIGITS>2</RIGHTDIGITS> <AXISLABEL>Voltage</AXISLABEL> <INTERVAL>36000</INTERVAL> </SENSOR> </STATION> DuoSens: Number: Name: OPW DuoSens Template Program Timezone: UTC/GMT +00:00 Activate DST for display and output: No Communication interface COM1: General: Baudrate: (8N1) Address no.: 1111 Password: - Activation control via switching output at terminal block: M 3-4 Activation times 1-4: 09:30 / 29:59 / 15:00 / 29:59 Duration ( 1..98, 99 = always on ): 60min Lag time [s]: 10 s Modem / Terminal adapter connected to RS232C: Yes Initializing: AT&FE0&D0S0=5+IFC=0,0 Dial no.: GSM modem: Yes GSM service center - phone no.: GSM service center - FAX no. prefix: PDU send string 1 (first 3 octets/smsc) [octets]: PDU send string 2 ( PDU-PID / -DCS / -VP ) [3 octets]: 00F6AA Self timed data transmission mode: 1 Cycle Standard: 24h Transmission start time offset: 07:15 Cycle Limit event: 2h Cycle Limit event: 2h Cycle Limit event: 2h Cycle Limit event: 2h Cycle Limit event: 2h Dial no.: Protocol type: OTT protocol binary Maximum number of additional SMS per transmission: 2 Channel(s) transmitted: 0001 Inmarsat-C transceiver connected to RS232: No ORBCOMM transmitter connected to RS232: No SDI-12 connected (RS232 disabled): No Alarm management: Address gro ups: Display / Observer: Observer Manual input: Yes Calculate manual input value with scaling: Yes Suppress display of instantaneous value before input: No Extended observer (store and transmit number): No Password for display ('Address No. / PIN' of COM1): Yes Date / time operation: Date and time Channel: Number: 0001 Name: Waterlevel Unit: m Decimal places: 3 Meas. cycle: Sample interval: 00:15:00 SDI-12 Master: Terminal block: A 3-4 Slave address: 0 Measurement mode: M! Value no.: 1 Value no. Virtual Terminal ID Etc etc

43 Now you are able to Export a configuration in a format, which Hydras 3 can import. Benefit: The names of station and sensors are taken over. Telephone number is insert on communication properties.

44 10 Hydras3 Settings Select Station Properties Make sure to enter 1111 as a password to access the data remotley if the password is set on the display of the DuoSens Select OK

45 10 - New Program Code (Firmware) DuoSens can be updated with new program code (Firmware) to implement new functions (e. g. update to V1.12 enables GPRS data transfer). Click DuoSens / new program code. Click Yes. If no connection is established, follow instructions. Normally memory has not to be deleted. Direct transfer is recommended (remote connections sometimes break down and DuoSens could freeze in). At least you should have the possibility to drive to the station in case of failure.

46 11 - Terminal Mode (for advanced users) In terminal mode all functions of menu DuoSens can be accessed with direct command and some more. Any command begins with CL/ Type CL/Help (and Enter) to list all commands with syntax and explanation. If problem occurs with DuoSens please try CL/Rebuild.

47 Connection and configuration of sensors

48 12 Things to remember RS485 (OTT SDI) is a bus system. The first and the last device of the bus should include a shunt resistor of 120 (CBS has dip switches to select RS485 with or without shunt). DuoSens has the shunt included (for the dedicated RS485 input), LogoSens not (because of universal inputs). SDI-12 input at LogoSens needs an additional connection of Gnd of the sensor (e. g. terminal block A3+A4) to Gnd of LogoSens (terminal block T3). You should also use a 4,7 k shunt resistor for the SDI-12 bus (till now skipped in OTT systems without problems). SE200 should be powered permanently (even during storage) to preserve internal battery 4-20 ma output of LogoSens as well as for all new OTT sensors is passive that means you need to set up a loop including power supply (check manual). First program configuration, then connect sensors.

49 12 Connections Check manuals of sensor (and datalogger) for physical connection! In general use RS485 connection (OTT SDI) if possible: longer distance because of high disturbance resistance (with twisted wires). Binary mode for firmware update (LogoSens, especially DuoSens)

50 12 OTTSDI // SDI-12 In channel 10 you define the virtual terminal V02 (e. g. PLS: first value is water level, second value is water temp.) In channel 130 no extra measurement is done (preferred! Saves time and all parameters belong to one time step). The value is given by virtual sensor V02 Changing the measurement mode to e. g. M1! gives access to different parameter set (depending on sensor).

51 12 Storage Delta Use storage delta module for precipitation measurement to save memory and transmission time! Can be used also for groundwater stations with slow/seldom changes of water level (e. g. change has to be 2 cm or greater).

52 12 Observer

53 Communication Physical connection and modem settings Protocols and data format: Software + Data transmission of DL (passive / active) Time sync:.

54 Baud Rate

55 MIS Format / OTT binary format

56 Error codes in Display - Sensor

57 Error codes in Display - Sensor

58 Error codes in Display - communication

59 Error codes in Display - communication

60 Testing

61 GPRS Modem Testing Useful Direct Modems Commands General Command AT Request Configuration Profile - AT&V Request Signal Quality AT+CSQ (8 less is poor; 0-31 Scale) Request SIM PIN - AT+CPIN? Verify the access point - AT+CGDCONT?

ATL20 ATL30 Automatic transfer switch controller

ATL20 ATL30 Automatic transfer switch controller I 194 GB 07 07 ATL20 ATL30 Automatic transfer switch controller REMOTE CONTROL SOFTWARE MANUAL Summary Introduction... 2 Minimum resources of the PC... 2 Installation... 2 Activation of the PC-ATL connection...

More information

Tech Tipp: Firmware-Update OTT netdl

Tech Tipp: Firmware-Update OTT netdl Tech Tipp: Firmware-Update OTT netdl Firmware-Update OTT netdl 6 options, to update the firmware of your OTT netdl : Please note: 1. On site with USB-stick 2. On site with laptop via USB cable 3. a) On

More information

Operating instructions Groundwater datalogger OTT CTD. English

Operating instructions Groundwater datalogger OTT CTD. English Operating instructions Groundwater datalogger OTT CTD English These operating instructions (version "01-1009") cover the OTT CTD software versions OTT CTD firmware from V 1.00.0 OTT CTD operating program

More information

HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction

HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction HD32MTLogger Software Manual for the instrument HD32MT.1 Introduction WARNING: The software must always be run as administrator! The HD32MTLogger program allows management of the HD32MT.1 datalogger from

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

DeltaLINK 3 Release Notes

DeltaLINK 3 Release Notes DeltaLINK 3 DeltaLINK 3.6 12 December 2016 Contents ABOUT DELTALINK 3...2 What s new in DeltaLINK 3.6... 2 Compatibility... 2 INSTALLATION...2 System Requirements... 2 To Install DeltaLINK... 3 To Start

More information

DATA LOGGER GEOLOGGER G8 PLUS

DATA LOGGER GEOLOGGER G8 PLUS A D V A C E D DATA LOGGER GEOLOGGER G8 PLUS I N S T CONFIGURATION & WIRING OF PERIPHERALS R U C T I O N M A N U A L 1 CONTENTS DESCRIPTION PAGE Main components 3 G8 Module Connections 4 G8 Module Connections

More information

Operating instructions Communication Software OTT Hydras 3 Rx. English

Operating instructions Communication Software OTT Hydras 3 Rx. English Operating instructions Communication Software OTT Hydras 3 Rx English We reserve the right to make technical changes and improvements without notice. 1 Table of contents 1 Table of contents... 3 2 Field

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere IMS II Automatic Weather Station Easy and reliable weather monitoring anywhere IMS Automatic Weather Station FEATURES: Synoptic Observation Climatological Observation Environmental Monitoring Radiation

More information

User Manual Revision 1.02

User Manual Revision 1.02 User Manual Revision 1.02 Manufactured by Contents 1. Introduction... 4 2. Disclaimer and Warranty... 4 3. Specifications... 5 4. Features... 5 5. Quick Start Guide... 6 5.1 Hardware... 6 5.2 Software...

More information

PADPULS2 M-BUS Pulse Input Modules

PADPULS2 M-BUS Pulse Input Modules Product sheet MT8.23 Meter Type PADPULS2 PADPULS2 M-BUS Pulse Input Modules The M-PADPULS series of devices connects meters with contact output to the M-Bus system. This is a simple and flexible solution

More information

SMS Transceiver V3 User manual

SMS Transceiver V3 User manual SMS Transceiver V3 User manual SMS Transceiver V3 - User manual ver. 1.8.3 - Fw: 3.0.7 - Sw: 1.6.2 Contents Page 1. Introduction 3 2. Connections 3 2.1 Inputs 3 2.2 Outputs 3 2.3 Power supply 3 2.4 Contacts

More information

X-Log Expert Data Logger

X-Log Expert Data Logger > data loggers X-Log Expert Data Logger Highlights Built-in internet stack with web server Setup and data display by any web browser Data-Push to up to three different FTP sites Internal FTP site for easy

More information

Communi-Cell Communicator Nokia Version

Communi-Cell Communicator Nokia Version Communi-Cell Communicator Nokia Version Jan 2007 Instruction Manual 1 ABOUT THE COMMUNI-CELL COMMUNICATOR SYSTEM The Communi-Cell Communicator system is based on GSM SMS technology. It uses a standard

More information

Tech Tipp: Datatransmission between two OTT netdl via IP (Ethernet)

Tech Tipp: Datatransmission between two OTT netdl via IP (Ethernet) Tech Tipp: Datatransmission between two OTT netdl via IP (Ethernet) Content Introduction of IP datatransmission between two OTT netdls a) Master/Slave-coupling b) Redundant system c) Coupling possibilities

More information

GSM communicator GD-06 Allegro Complete manual

GSM communicator GD-06 Allegro Complete manual GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or

More information

GPRS Pager 3 INSTALATION AND USER MANUAL

GPRS Pager 3 INSTALATION AND USER MANUAL GPRS Pager 3 INSTALATION AND USER MANUAL 1 Table of contents 1 Main functions of the GPRS Pager3...3 2 Operating mode, installation...3 2.1 Installation if no local network is available...3 2.2 Instalation

More information

: DOOR ENTRY UNIT. Programming Software USER MANUAL

: DOOR ENTRY UNIT. Programming Software USER MANUAL : DOOR ENTRY UNIT Programming Software MODELS: EIS-1, EIS-2 OR EIS-4 v.02 2018 Contents 1 FOR YOUR SAFETY...4 2 INTRODUCTION...5 3 EIS-1, EIS-2, EIS-4 FEATURES AND APPLICATIONS...6 4 START UP...7 5 LED

More information

Software Description Application Software OTT Hydras 3 net

Software Description Application Software OTT Hydras 3 net English Software Description Application Software OTT Hydras 3 net We reserve the right to make technical changes and improvements without notice! Table of contents 1 Overview of OTT Hydras 3 net 5 2 Data

More information

FService. Software for configuration and readout of Relay M-Bus centrals. User Manual

FService. Software for configuration and readout of Relay M-Bus centrals. User Manual Software for configuration and readout of Relay M-Bus centrals User Manual Content 1 Configuring M-Bus masters with FSERVICE... 3 1.0 What is FSERVICE?... 3 1.1 Installation... 3 1.2 Usage... 4 1.3 Basic

More information

Docking Station DS-U4WEB with web server version 1 Instruction Manual

Docking Station DS-U4WEB with web server version 1 Instruction Manual Page 1 of 15 Docking Station DS-U4WEB with web server version 1 Page 2 of 15 Table of contents 1 Overview... 3 2 Description... 3 2.1 Connector identification... 3 2.2 Probe inputs... 4 2.3 Logical inputs

More information

Power Vision 1.7 (Cod )

Power Vision 1.7 (Cod ) ELECTRICAL NETWORK ANALYSIS SOFTWARE Power Vision 1.7 (Cod. 775 353) USER S MANUAL (Cod. M 981 358 / 05B) 2005 - CIRCUTOR, S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION...4 2.- INTRODUCTION TO POWER

More information

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

GPRS-T1. Monitoring Converter. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Monitoring Converter GPRS-T1 Program version 1.01 gprs-t1_en 04/09 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl WARNINGS The module should only

More information

POWER VISION INSTRUCTION MANUAL

POWER VISION INSTRUCTION MANUAL NETWORK ANALYSIS SOFTWARE POWER VISION INSTRUCTION MANUAL (M98135801-03-11B) CIRCUTOR S.A. INDEX 1.- POWER VISION SOFTWARE INSTALLATION... 4 2.- INTRODUCTION TO POWER VISION... 12 3.- COMMUNICATIONS...

More information

GCR-16 with internal modem GXR user manual appendix J

GCR-16 with internal modem GXR user manual appendix J GCR-16 with internal modem GXR user manual appendix J GeoSIG Ltd, Ahornweg 5a, 5504 Othmarsingen, Switzerland Phone: + 41 44 810 2150, Fax: + 41 44 810 2350 info@geosig.com, www.geosig.com ii GXR manual

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

MultiLog LX logger. MultiLog LX USER MANUAL

MultiLog LX logger. MultiLog LX USER MANUAL Page 1 MultiLog LX USER MANUAL 34, route de Saint Romain - 69450 St Cyr au Mont Or - France Tél. +33 (0)4 72 53 11 53 - Fax +33 (0)4 78 83 44 37 - e-mail : hydreka@hydreka.fr Version Janvierr 2009 Page

More information

Version 1.0c May 6, 2010 ATK3

Version 1.0c May 6, 2010 ATK3 Version 1.0c May 6, 2010 ATK3 Contents 1 Hardware 2 1.1 Inputs............................... 2 1.2 Outputs.............................. 3 1.3 RS485............................... 3 1.4 Ethernet..............................

More information

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software : DOOR ENTRY UNIT EIS-LCD Programming Software v.2.0 2018 Page 1 Contents 1 FOR YOUR SAFETY...5 2 INTRODUCTION...6 3 EIS-LCD, EIS-40 FEATURES AND APPLICATIONS...7 4 START UP...8 5 LED INDICATION...9 6

More information

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide

RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software. Getting Started Guide 1 RTU8 Compact Telemetry Outstation IOTOOL32 PRO Software Getting Started Guide V. 1.00 / Feb 2006 / Doc 40031 2 1. Introduction The RTU8 range of Compact Telemetry Outstations provide an efficient and

More information

AANDERAA. DATALOGGERS 3634 and 3660

AANDERAA. DATALOGGERS 3634 and 3660 DATALOGGERS 4 and 0 A rugged unit for reading standard Aanderaa sensors and for displaying, storing and transmitting the data in engineering units. Datalogger 4, channels Datalogger 0, 18 channels DATA

More information

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND OleumTechTM TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND MUST BE FAMILIAR WITH LEVEL 1 TRAINING MATERIALS BEFORE MOVING FORWARD Doc ID# 80-6010-001b TABLE OF CONTENTS 1. WHAT IS NEW WRITE IMPORT

More information

Poseidon 4002 MANUAL

Poseidon 4002 MANUAL Poseidon 4002 MANUAL Poseidon 4002 MANUAL POWER input 12VDC supply (jack or terminals) INPUTS Binary inputs 1 6 (for contacts) OUTPUTS Two 50V rated switchover relay contacts ETHERNET 10 or 100/10 Mbps

More information

M2500 Engine Controller Configuration Manual

M2500 Engine Controller Configuration Manual M2500 Engine Controller Configuration Manual Revision: 08-04-2011 Page 1 Contents 1 Preface... 4 2 Configuration from front panel... 5 2.1 Engine Controller Configuration... 6 2.1.1 RPM settings... 6 2.1.2

More information

Manual for firmware 1.15 and subsequent

Manual for firmware 1.15 and subsequent GSM Controller v3.0 Manual for firmware 1.15 and subsequent GSM Controller GSM v3 controller allow monitor by gsm network different phisical parameters and control remotely on/off 5 outputs. Control is

More information

Tu Sitio de Automatización!

Tu Sitio de Automatización! 1. Overview a. Introduction Tu Sitio de Automatización! LBSMS Basic-Q421 is integrated with a 16 bit MCU and reliable Siemens MC39i GSM module. b. Application Industrial equipment monitoring Data capturing

More information

TFS 2100 Traveling Wave Fault Location System

TFS 2100 Traveling Wave Fault Location System Traveling Wave Fault Location System The most accurate overhead transmission and distribution line fault locator Accuracy: ±150m typical regardless the line length Unaffected by fault resistance Suitable

More information

GS828-H. GPRS Data Logger

GS828-H. GPRS Data Logger GPRS Data Logger GS828-H Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors via

More information

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed.

This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed. This document is in addition to the product manual and provides extra information. The OCIO Instruction manual must also be reviewed. The OCIO GSM system Transmit tank levels, via SMS and e-mail, on request.

More information

List of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU...

List of Contents 1. INTRODUCTION DEFINITIONS AND ABBREVIATIONS REFERENCES TECHNICAL DATA GENERAL MODBUS RTU... MAGX2 RTU User Guide -0- V1.5 23-01-2018 List of Contents 1. INTRODUCTION... 2 1.1 DEFINITIONS AND ABBREVIATIONS... 2 1.2 REFERENCES... 2 2. TECHNICAL DATA... 3 2.1 GENERAL MODBUS RTU... 4 3. COMMISSIONING...

More information

ADVANCED OPERATOR PANEL (AOP)

ADVANCED OPERATOR PANEL (AOP) ADVANCED OPERATOR PANEL (AOP) Operating Instructions Issue 04/02 English Contents 1 Warnings and Notes 3 1.1 Special Key Functions 4 2 Applications Examples 4 2.1 Single drive control using the AOP 4 2.2

More information

GS828. GPRS Data Logger

GS828. GPRS Data Logger Sirius Corp GPRS Data Logger Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors

More information

RTS ISDN 2002 System. Operator Manual Software Description

RTS ISDN 2002 System. Operator Manual Software Description RTS ISDN 2002 System Operator Manual Software Description PAGE 1-2 RTS ISDN 2002 System A Publication of EVI Audio GmbH Hirschberger Ring 45 D-94315 Straubing Telephone + 49 9421 706-0 Fax + 49 9421 706-422

More information

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display

Datalogger Gealog SG. Datalogger Gealog SG. Gealog SG with graphic display Gealog SG with graphic display Page 1 of 13 Innovation leader in environmental monitoring stations The Gealog SG datalogger was especially designed for application in hydrometeorological measuring stations.

More information

Comgraph32. Data Retrieval and Analysis for COMBILOG. Version Page 1. Comgraph32. data retrieval and analysis for Combilog version 3

Comgraph32. Data Retrieval and Analysis for COMBILOG. Version Page 1. Comgraph32. data retrieval and analysis for Combilog version 3 data retrieval and analysis for Combilog version 3 Page 1 3 09.00 2 04.00 Ra 1 01.99 Ra Issue Date Name Feingerätebau K.Fischer GmbH Venusberger Straße 24 D-09430 Drebach Germany Phone +49 (0) 37341 /

More information

KTA-250 Anemometer Alarm Card

KTA-250 Anemometer Alarm Card Connects to Davis Instruments DS7911 Anemometer Monitor both the wind speed and direction Interface to PLCs using the Modbus protocol Communicate via RS232 or 2-wire RS485 Interface to PLCs/Instruments

More information

SOFTWARE VERSION 3.10

SOFTWARE VERSION 3.10 728PEP-03 SOFTWARE VERSION 3.10 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

Expansion modules M-CVM-AB-8I-8OTR. Description Expansion module with 8 digital inputs and 8 transistor outputs. Maximum power consumed

Expansion modules M-CVM-AB-8I-8OTR. Description Expansion module with 8 digital inputs and 8 transistor outputs. Maximum power consumed -8I-8OTR Expansion module with 8 digital inputs and 8 transistor outputs. Digital inputs Reports via communications: Logic states of non-unit external systems Metering of the impulses generated by other

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M

IMS4 AMS 111 II M. Automatic Mobile Weather Station for military usage AMS 111 II M IMS4 Automatic Mobile Weather Station for military usage FEATURES: Military class equipment Military design optional Aviation weather observation Climatological observation Synoptic observation Radiation

More information

The CONFIGURATOR. User Guide. Web-site: Tel: Fax:

The CONFIGURATOR. User Guide. Web-site:   Tel: Fax: Web-site: www.remmon.com Tel: 972-4-6065815 Email: remmon@remmon.com Fax: 972-4-6065819 The CONFIGURATOR User Guide 2005 Remmon Ltd. All rights reserved Version 1.0 i Web-site: www.remmon.com Tel: 972-4-6065815

More information

Stevens SatComm. Product GUI Quick Start Guide

Stevens SatComm. Product GUI Quick Start Guide Stevens SatComm Product GUI Quick Start Guide Stevens Part #93876 June 2013 Contents 1. Product Overview... 3 2. Opening SatCommSet... 4 3. SatComm Setup Tabs... 6 3.1 SatComm Setup Tab... 6 3.2 Self Timed

More information

1 Introduction Required components Datalogger TrueLog Baseboard... 1

1 Introduction Required components Datalogger TrueLog Baseboard... 1 - 1 Contents 1 Introduction... 1 2 Required components... 1 2.1 Datalogger TrueLog100... 1 2.1.1 Baseboard... 1 2.1.2 Battery holder with 2 pole power plug... 1 2.2 USB cable for logger configuration...

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor

INDEX. Network Power Monitor NPM-R10-SNMP. Innovative Electronics for a Changing World. NPM-R10-SNMP Remote Network Power Monitor Innovative Electronics for a Changing World NPM-R10-SNMP Remote Network Power Monitor Optional relay board and GSM module INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM BATTERY CONNECTIONS 3. SERIES CONNECTED BATTERIES

More information

SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT USER MANUAL

SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT USER MANUAL SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT Contents 1 FOR YOUR SAFETY... 4 2 INTRODUCTION... 5 3 SOLO-KP AND SOLO-KP LCD FEATURES AND APPLICATIONS... 6 4 START UP... 7 5 LED INDICATION...

More information

CONFIGURATION HANDBOOK

CONFIGURATION HANDBOOK CONVERTER FOR ABSOLUTE SSI ENCODER CONFIGURATION HANDBOOK CNL35 SSI LOREME 12, rue des Potiers d'etain Actipole BORNY - B.P. 35014-57071 METZ CEDEX 3 Phone 03.87.76.32.51 - Telefax 03.87.76.32.52 Contact

More information

GEN II Wireless GSM/GPRS Data Acquisition System

GEN II Wireless GSM/GPRS Data Acquisition System Real time and historic data is sent via GPRS to the main server where it is written to a MySQL database Server MySQL Database SMS alarm messages sent to mobile phones Email alerts and reports sent to specified

More information

D2 RMSM/ T1K RSSS Remote I/O System

D2 RMSM/ T1K RSSS Remote I/O System D2 RMSM/ 2 2 D2 RMSM/ Remote Master (D2-RMSM) Features RUN--Turns N when the module is operating correctly. Remote Master DIAG--Turns N when there is a hardware failure. I/--Turns N when the setup program

More information

SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS

SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS Contents 1 FOR YOUR SAFETY... 3 2 INTRODUCTION... 4 3 SOLO-NX FEATURES AND APPLICATIONS... 5 4 START UP... 6 5 LED INDICATION... 7 6

More information

RITZ / Turbine controls DISPLAY

RITZ / Turbine controls DISPLAY RITZ / Turbine controls DISPLAY CANCEL EXIT OK MENU F1 F2 F3 F4 The control/display unit has a CPU, an LCD display and 8 keys. 2 LEDs also display particular operational conditions (e.g. plant ON, faults,

More information

InTimeGo-623 Pets GPS Tracker User Manual

InTimeGo-623 Pets GPS Tracker User Manual InTimeGo-623 Pets GPS Tracker User Manual Product & Lock Unlock: CCTR-623 tracker 1 set, 1 locking dock, 1 collar, 1 screwdriver, 1 USB Charging Wire, Manual (CD or Print), AC Charger (Optional). Collar

More information

Contents LOCAL MANAGEMENT LOGIN INTERFACE RECORD SEARCH: LOG SEARCH SYSTEM STATUS BASIC SETUP.

Contents LOCAL MANAGEMENT LOGIN INTERFACE RECORD SEARCH: LOG SEARCH SYSTEM STATUS BASIC SETUP. User Manual For MD AHD MDVR Copyright 2013-2016, Howen Technology Co., Ltd All Rights Reserved 1-59 Contents 1. 2. LOCAL MANAGEMENT... 3 2.1. LOGIN INTERFACE... 3 2.2. RECORD SEARCH:...6 2.3. LOG SEARCH...

More information

PowerVision Plus 1.3

PowerVision Plus 1.3 SOFTWARE FOR ELECTRICAL NETWORK ANALYSIS 1.3 USER MANUAL (M98232901-03-12B) 2012 - CIRCUTOR, S.A. 2 1. Installation of software... 7 2. Introduction to... 11 2.1. Brief description of the application....

More information

SOFTWARE VERSION 3.20

SOFTWARE VERSION 3.20 48EPEP-00 SOFTWARE VERSION 3.20 HEXA PROGRAMMING: Addresses 000 to 043 and 300 to 527 are programmed using the Hexa Programming method. In this mode, you can enter any hexa-digit from 0-F where keys [1]

More information

NX21 USER MANUAL. Telemetry Unit. Version 1.5

NX21 USER MANUAL. Telemetry Unit. Version 1.5 USER MANUAL Version 1.5 Nortech Management Ltd, United Kingdom NOV 2016 www.nortechonline.co.uk Doc Ref D_000344 Publication Notice Copyright Nortech Management Limited (NML). All rights reserved. No part

More information

Use this manual with the following Analogue Fire control panels: FC200/S - 2 Loop Master panel with 2.5 A Switching power supply

Use this manual with the following Analogue Fire control panels: FC200/S - 2 Loop Master panel with 2.5 A Switching power supply SOFTWARE MANUAL Use this manual with the following Analogue Fire control panels: FC200-2 Loop Master panel with 4 A Linear power supply FC200/S - 2 Loop Master panel with 2.5 A Switching power supply FC200/SL

More information

DATA ACQUISITION Hints and Tips

DATA ACQUISITION Hints and Tips How to use the SquirrelView software with the SQ2010/SQ2020/SQ2040 Data Loggers. SquirrelView Help Page 2 Connecting Your Squirrel Data Logger Page 2 Logger Set-up Page 3 Download Data Page 8 Export Data

More information

HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS

HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS HWg-Tg11 Manual HWg-Tg11 First steps for remote monitoring & logging via GSM/GPRS Device description Power supply connector - RJ12 connector Device status indicators Red, Green, Yellow indicators Antenna

More information

GSM AUTO DIALER WITH IR BEAM DETECTOR

GSM AUTO DIALER WITH IR BEAM DETECTOR GSM AUTO DIALER WITH IR BEAM DETECTOR Remote Monitoring & Control using your mobile phone. www.gsm-activate.co.uk MODEL NUMBER IRV2 Page 1 Product Information Our GSM Auto-Dialer is a versatile unit which

More information

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50 MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287 Installation and Operations Manual 00-02-0651 09-01-09 Section 50 In order to consistently bring you the highest quality, full featured products,

More information

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016 Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation

More information

USER MANUAL FOR GS100/GS1003G

USER MANUAL FOR GS100/GS1003G USER MANUAL FOR GS100/GS1003G 1 Table of Contents 1. INTRODUCTION... 3 2. FEATURES... 3 3. OPERATION... 3 4.CONNECTION DETAILS... 4 5.CONFIGURATION... 5 5.1 Hyper Terminal Setting... 5 5.2 GS100 Configuration...

More information

NMCnet User Manual. Table of Contents

NMCnet User Manual. Table of Contents NMCnet Table of Contents NMCnet Basic Requirements... 3 nstallation NMC Net Communication Program... 4 Network Setup... 5 Local Network... 5 Modem Network... 7 Modem Communication Setting... 7 Demo Network...

More information

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902

3690 N.W. 53rd Street Fort Lauderdale, FL SC-2124 SC-2124M. 24 Channel Universal Scanner. Installation and Operation Manual P/N 145F-11902 3690 N.W. 53rd Street Fort Lauderdale, FL 33309 SC-2124 SC-2124M 24 Channel Universal Scanner Installation and Operation Manual P/N 145F-11902 Rev. 3.30 (c) Copyright 2000, Dynalco Controls All Rights

More information

IPassan Installation guide

IPassan Installation guide IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...

More information

InTimeGo-630 GPS Watch Tracker User Manual

InTimeGo-630 GPS Watch Tracker User Manual InTimeGo-630 GPS Watch Tracker User Manual Product: CCTR-630 Watch 1 set, Mini USB Charging Wire, Manual (CD or Print), AC Charger (Optional), Water-proof Bag for Pets Belt(Optional). Charging ON/OFF SOS

More information

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL

AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL AM3 Humidity. Temperature. Dew Point Indicator INSTRUCTION MANUAL CONTENTS 1. Battery Operation... 3 2. Operation with a Rechargeable Battery... 3 3. Humidity and Temperature Probe (Probe Input 1)... 3

More information

CCTR-820 Mini Water-proof GPS Tracker Using Guide

CCTR-820 Mini Water-proof GPS Tracker Using Guide CCTR-820 Mini Water-proof GPS Tracker Using Guide Welcome to use this Real Time mini water-proof GPS tracker CCTR-820, This product is with GPS module and GSM module, It is specially design for motor,

More information

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs MobilTherm 2ad GSM temperature alarm module with auxiliay inputs and relay outputs The MobilTherm-2ad is a GSM temperature and remote signaling module, designed for GSM based remote control, remote signal.

More information

THE WORLD OF WEATHER DATA

THE WORLD OF WEATHER DATA THIES Clima Meteorology and Environmental measurements. Datalogger DL16 PRO 2009 Adolf Thies GmbH & Co. KG 1 Content 1. Highlights 2. Introduction 3. Connectivity 4. Configuration 5. Miscellaneous Configuration

More information

OCIO GSM. M0148ITEN rev. 1 ENGLISH

OCIO GSM. M0148ITEN rev. 1 ENGLISH OCIO GSM M0148ITEN rev. 1 ENGLISH 1 2 1. INTRODUCTION 2. INSTALLATION 2.1 Ocio Installation 2.2 SIM Card Installation 2.3 Installing the system with 1 Ocio 2.4 Installation of one expansion 2.5 Installation

More information

Technical Documentation

Technical Documentation BLR-CM - MODBUS Technical Documentation BLR-CM MODBUS Beluk GmbH Tel.: +49/(0)8861/2332-0 Fax: +49/(0)8861/2332-22 e-mail: blr@beluk.de http://www.beluk.de BLR-CM - MODBUS Page 2 of 20 Document history

More information

DNP 3.0 Communication User s Manual

DNP 3.0 Communication User s Manual MV Network management MV/LV substations remote monitoring Merlin Gerin Easergy Range Easergy FLAIR 200C DNP 3.0 Communication User s Manual Summary SUMMARY...3 SOFTWARE CONFIGURATION...4 DEVICE PROFILE

More information

Pen Drive USB Datalogger!

Pen Drive USB Datalogger! SINGLE PHASE POWER METER Isolated V/I converter -RS485 Modbus - Datalogger Single-phase power meter RMS, and Voltage/Current Isolated. Signal Converter 1000 VDC / 600 VAC, 10 A AC/DC, Variable frequency

More information

ProLine GSM. Installation manual

ProLine GSM. Installation manual Installation manual ContentS Description of device functions... page 3. Line simulkator function... page 3. Description of the terminal block... page 4. Installation instructions... page 4. LED signals...

More information

ZLJ\YP[`7YVIL, :[HUKHYK

ZLJ\YP[`7YVIL, :[HUKHYK :LUZVY *VU[YVS :LUZVY *VU[YVS (JJLZZ *VU[YVS (JJLZZ *VU[YVS ZLJ\YP[`7YVIL, :[HUKHYK ZLJ\YP[`7YVIL, :[HUKHYK Monitor the physical environment and receive alerts of any disturbances, such as unauthorized

More information

Win Com 5 USER S MANUAL

Win Com 5 USER S MANUAL Win Com 5 USER S MANUAL 11/2003 Table of contents 1. Installation...1 2. Overview...1 3. Quick start...2 4. File menu...3 4.1 View connection log... 3 4.2 View alarms... 4 4.3 View vmachs data... 5 4.4

More information

INDEX. Network Power Monitor R10 SNMP

INDEX. Network Power Monitor R10 SNMP Innovative Electronics for a Changing World NPM-R10 Remote Network Power Monitor With optional relay board and GSM module INDEX Amended 21 March 2017: Add user defined Password see page 13 Add wire Connection

More information

ALERT CONFIGURATION GUIDE SIA DRIVER

ALERT CONFIGURATION GUIDE SIA DRIVER ALERT CONFIGURATION GUIDE SIA DRIVER 1) Installation A) SIA modem installation The SIA modem must be connected to a serial port on the PC (COM1, ) and plugged in an analog phone line. The modem being completely

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

Bus & Signal Processing

Bus & Signal Processing Prototyping Electronic Devices Class 12 Bus & Signal Processing Deqing Sun, Peiqi Su ITP, Fall, 2018 What is bus 2 Differences between Bus and Cab? 3 Differences between Bus and Cab Bus is capable to carry

More information

7SG18 Solkor N Numeric Differential Protection

7SG18 Solkor N Numeric Differential Protection 7SG18 Solkor N Numeric Differential Protection Document Release History This document is issue 2010/02. The list of revisions up to and including this issue is: Pre release 2010/02 Document reformat due

More information

180 Series Keypad. Handbook. Revision 2.1

180 Series Keypad. Handbook. Revision 2.1 180 Series Keypad Handbook Revision 2.1 Revision History Revision 1.0 Initial release Revision 2.0 Major update with addition of 180-40 Added 180-40 to document and various headings Note regarding unique

More information

GSM Unit PU from software version Connecting cable RJ 12/ RJ 12, enclosed

GSM Unit PU from software version Connecting cable RJ 12/ RJ 12, enclosed Document number A 30594 00 IT 74 1 CMC-TC GSM Unit DK 7320.820 Important note: For reasons of clarity, these user instructions contain only the most significant details and information and similarly cannot

More information

Parallel SelfSensing Modulating Pump Controller

Parallel SelfSensing Modulating Pump Controller Parallel SelfSensing Modulating Pump Controller Installation, Operation, and Maintenance Manual 302-380 SUPERSEDES: New EFFECTIVE: November 15, 2016 Plant ID: 001-0000 Table of Contents Connecting Controler...

More information

FSERVICE Software setup toolkit for M-Bus masters and dataloggers

FSERVICE Software setup toolkit for M-Bus masters and dataloggers FSERVICE Software setup toolkit for M-Bus masters and dataloggers Version 1.9 Inhaltsverzeichnis 1 Configuring M-Bus masters with FSERVICE...2 1.0 What is FSERVICE?...2 1.1 Installation...2 1.2 Usage...2

More information

Innovative Electronics for a Changing World INDEX

Innovative Electronics for a Changing World INDEX Innovative Electronics for a Changing World INDEX 1. SYSTEM DESCRIPTION 2. BOARD CONNECTIONS terminals and indicators 3. CONNECTION DIAGRAM 4. START UP GUIDE and passwords 5. HOME PAGE 6. STATUS PAGE 7.

More information

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06

DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06 DS-4483 Standard Logger Program Quick Reference For Software Version: 4.06 Requires Firmware Version: VL/2.17+ Revision History: Version 1.00 02 February 2004 Preliminary release version Version 4.01 21

More information