Temperature Measurement SITRANS TS300

Size: px
Start display at page:

Download "Temperature Measurement SITRANS TS300"

Transcription

1 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø ( ) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø D3 Ø D Measuring insert length Ød Measuring insert outer diameter (6 (0.4)) Process connection outer diameter 3 Protective pipe inner diameter H Head height H 1 Type Axx = 41 (1.61) Type xx = 6 (1.0) N Nominal length U Insertion length X Extension length modular design, dimensions in mm (inch) /48 Siemens FI

2 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Selection and Ordering data Article No. Order code 7MC8005- for food, pharmaceuticals and biotechnology, modular design for installation in pipelines and vessels Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Head Stainless steel head, S0, screw cover 5 (Standard version) Aluminum head, A0, flange cover standard 1 Plastic cover, M0, srew cover Aluminum head, 0, hinged cover low 3 Aluminum head, C0, hinged cover high 4 9 H 1 Y Process connection, material or /316L Milk pipe union to DIN with slotted union nut and nominal diameter/pressure DN 5/PN 40 A A DN 3/PN 40 A DN 40/PN 40 A C DN 50/PN 5 A D Clamp connection: ISO 85 DIN 3676 Tri-Clamp Outer diameter D ½"/ ¾" 5.0 mm C A DN 5/ 33.7/38 DN 5/3/40 1", 1½" 50.5 mm C DN 40/51 DN 50 " 64.0 mm C C DN 63.5 ½" 77.5 mm C D DN 88.9 DN mm C E Varivent connection (Tuchenhagen) D 6 = 50 mm (1.97 inch), K U for Varivent housing DN 5 and DN 1" D 6 = 68 mm (.68 inch), K V for Varivent housing DN and 1½"... 6" NEUMO/ioControl Size 5 A Size 50 Size 65 C Ingold flange DN 5 with hexagon union nut G 1¼", J A mounting length 40 mm (1.57"), diameter 4.8 mm (0.98") incl. O-ring Welding piece L A (sphere diameter 30 x 40 mm (1. x 1.6 inch) long) Z A Type of screwed gland and nominal diameter Protective tube Measuring insert Ø D = 6 mm Ø 3/3. mm, 1 (0.4 inch) (0.1/0.13 inch) miner. insul. Ø D =9 mm Ø 6 mm (0.4 inch) (0.35 inch) Ø D =9 mm Ø 6 mm (0.4 inch) 3 (0.35 inch) miner. insul. Ø D =9 mm (0.35 inch) tapered tip D =5 Ø x 0 mm (0. x 0.79 inch) Ø 3/3. mm, (0.1/0.1 inch) miner. insul. 4 J 1 Y 9 L 1 Y Selection and Ordering data Article No. Order code 7MC8005- for food, pharmaceuticals and biotechnology, modular design for installation in pipelines and vessels Neck tube length X 65 mm (.56 inch) [M = 80 mm (3.15 inch)] mm (5.1 inch) [M = 145 mm (5.71 inch)] 9 N 1 Y Insertion length Enter customer specific length with Y44, see Order codes below 15 mm (0.59 inch) mm ( inch) C Initial: 35 mm (1.38 inch) mm ( inch) D Initial: 50 mm (1.97 inch) mm ( inch) E Initial: 100 mm (3.94 inch) mm ( inch) F Initial: 160 mm (6.30 inch) mm ( inch) G Initial: 50 mm (9.84 inch) mm ( inch) H Initial: 400 mm (15.75 inch) inch, Initial: 4 inch J inch, Initial: 6 inch K inch, Initial: 9 inch L Z P 1 Y Sensor Thin-film technology: measuring range C ( F) x Pt100, class A, three-wire G 1 x Pt100, class A, four-wire H Z Q 1 Y Further designs Order code Add "-Z" to Article No. and add Order code Process connection completely electropolished P01 Hygiene version H01 (R a < 0.8 m (3.1 x 10-5 inch)) Certificates Roughness depth measurement R a certified by factory certificate to EN C18 Material certificate to EN C1 TAG plate made of stainless steel Y15 specify TAG No. in plain text Test report (at 0, 50 and 100%) Y33 specify measuring range in plain text If optional head transmitters are integrated, please note that all calibration points are located in the set measuring range. If the points are located outside the standard measuring range, a Y01 addition is always required. Insertion length customer-specific Y44 Select range, enter desired length in plain text (No entry = standard length) Siemens FI /49

3 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Conical connection with union nut according acc. to DIN Tri-Clampconnection Clamp- connection acc. to DIN 3676 or ISO 85 all weld sleeve all 30 x 40 (1.18 x 1.58) D6=30 (1.81) 6 6 G1A without dead space due to conical metal cone G1A Varivent connection 6 Øda NEUMO iocontrol 6 Ingold connection DN 5 with union nut SW 46 L=40 (1.58) Ø4.8 (0.98) O-ring EPDM Protective pipe design based on DIN 4377 U Form 3 (0.1) Similar to form 3 tapered tip U 0 (0.79) 3 (0.1) Process connections, dimensions in mm (inch) /50 Siemens FI

4 Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Selection and Ordering data Order code Further designs Add "-Z" to Article No. and specify Order code. uilt-in head transmitter Measuring range to be set must be specified with plain text data "Y11". SITRANS TH100, ma, Pt100 T10 SITRANS TH100 Ex i (ATEX), ma, Pt100 T11 SITRANS TH00, ma, universal T0 SITRANS TH00 Ex i(atex), ma, universal T1 SITRANS TH300, HART, universal T30 SITRANS TH300 Ex i (ATEX), HART, universal T31 SITRANS TH400 PA, universal T40 SITRANS TH400 PA Ex i, universal T41 SITRANS TH400 FF, universal T45 SITRANS TH400 FF Ex i, universal T46 Transmitter options Transmitter, enter complete setting in plain text Y11 (Y11:+/-NNNN... +/-NNNN C,F) Enter measuring point (max. 8 characters) in plain Y17 text Transmitter, enter measuring point description (max. Y3 16 characters) in plain text Transmitter, enter measuring point text Y4 (max. 3 characters) in plain text Transmitter, enter bus address in plain text Y5 Transmitter, fail-safe value 3.6 ma U36 (instead of.8 ma) Transmitter with a SIL conformity C0 Transmitter with a SIL /3 conformity C3 Transmitter test protocol (5 points) C11 Further options Connection form, flying leads (for the direct transmitter assembly, delivery without screws and springs) G01 M1 device plug (in combination with 1x Pt100 G1 and/or transmitter, Non-Ex) Option not found? Specify special version in plain text Y98 Process number for the special version Y99 Accessories, see page /38. Siemens FI /51

5 Siemens AG 018 For food, pharmaceuticals and biotechnology clamp-on design Dimensional drawings Vibration-locking-screw Mounting screws 3 Process pipeline 4 Temperature sensor 5 Thermal decoupling 6 Spring load 7 Electrical connection M1 8 Replaceable measuring insert 9 Heat insulated pipe collar 3 1 Resitance thermometer with protection pipe in Clamp-on design /5 Siemens FI

6 Siemens AG 018 For food, pharmaceuticals and biotechnology clamp-on design Selection and Ordering data Article No. Ord. code 7MC for food, pharmaceuticals and biotechnology Clamp-on design for the measuring of the pipe surface temperature Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Design Acc. to IEC 60751, class A 1 [ C ( F)] Type of connection Device plug M1 x 1 A connection head form, stainless steel ma compact transmitter C SITRANS TH100slim (standard measuring range C ( F)) Mounting with pipe collar Pipe outer-ø mm (inch) 4 (0.16) Collar size mm (inch) A1 6 (0.4) (0.5) C1 8 (0.31) D (0.37) E1 10 (0.39) F (0.40) 50 x 35 x 0 G1 (1.97x1.38x0.79) 10.3 (0.41) H1 1 (0.47) J (0.50) K1 13 (0.51) L (0.53) M (0.54) N1 14 (0.55) P (0.6) Q1 16 (0.63) R1 17. (0.68) S (0.71) A 19.0 (0.74) (0.75) C 0.0 (0.79) D 1.3 (0.84) E.0 (0.87) F 3.0 (0.90) G 4.0 (0.94) H 5.0 (0.98) J 5.4 (1.00) K 6.7 (1.05) L 6.9 (1.06) M 70 x 70 x (1.10) (.76x.76x0.79) N 9.0 (1.14) P 30.0 (1.18) Q 31.8 (1.5) R 3.0 (1.6) S 33.4 (1.31) T 33.7 (1.33) U 34.0 (1.34) V 35.0 (1.38) W 36.0 (1.4) X 38.0 (1.49) Y Selection and Ordering data Article No. Ord. code for food, pharmaceuticals and biotechnology Clamp-on design for the measuring of the pipe surface temperature 7MC (1.50) A (1.61) (1.67) C (1.75) D (1.90) 90 x 85 x 0 E (.00) (3.54 x 3.35 x 0.79) F (.09) G (.13) H (.4) J 3 Always indicate external tube diameter for 1) : Installation with tube collar and deviating external tube diameter (S11-S19) Securing with clamps (S1-S3) Clamping band installation (S31-S35) Z 0 K1 Y 1) Special sizes for pipe outer diameters: In order to process "Z0" special sizes, the following two additional items of information are essential: - the required diameter specified in plain text under "K1Y" - Selection of the corresponding pipe collar, clamping band or clamping bracket size (Order codes "S11" to "S35") Recommended for all versions: Heat-conductive-compound, siliconefree, syringe 3 g, Order code: L15 (see page /55) Siemens FI /53

7 Siemens AG 018 For food, pharmaceuticals and biotechnology clamp-on design Dimensional drawings Measuring transducer with device plug M1x1 Field housing, screw cap Material stainless steel IP 67 Ø60 (.36) 11.5 (0.45) Device plug M1x1 max. 9 (1.41) 94 (3.70) ~ 83.5 (3.70) 51 (.01) Electrical connection can be rotated by ± 170 Device plug M1x1 19 (0.75) Cable gland M1x1.5 for cable Ø ( ) Clamp-on, clamping block installation for pipelines Ø ( ) 0 (0.79) Clamp-on, clamping band installation with hose clamps for pipelines Ø10... ca. 300 ( ca.11.81) 36 (1.4) 37 (1.46) Cable gland M16x1.5 for cable Ø ( ) 3 (0.91) A C Example Ø1 (4.76) 19 (0.75) Clamp-on, latch fastener installation for pipelines Ø ( ) A Pipe radius 3 (0.1) C 6 (0.4) 0 (0.79) Pipe diameter C ( ) (1.18) (1.38) ( ) (1.57) (.36) ( ) (1.97) (3.15) Latch fastener version Pipe diameter A C H ( ) (0.79) (1.18) (1.38) (3.11) ( ) (1.18) (1.57) (.76) (3.90) ( ) (1.57) (1.97) (3.35) (4.68) Standard version Clamp-on design, device plug, field housing, cable gland, variants, dimensions in mm (inch) /54 Siemens FI

8 Siemens AG 018 For food, pharmaceuticals and biotechnology clamp-on design Selection and Ordering data Further designs Add "-Z" to Article No. and specify Order code. uilt in head transmitter Measuring range to be set must be specified with plain text data "Y11". SITRANS TH100, ma, Pt100 SITRANS TH100 Ex i (ATEX), ma, Pt100 SITRANS TH00, ma, universal SITRANS TH00 Ex i (ATEX), ma, universal SITRANS TH300, HART, universal SITRANS TH300 Ex i (ATEX), HART, universal SITRANS TH400 PA, universal SITRANS TH400 PA Ex i, universal SITRANS TH400 FF, universal SITRANS TH400 FF Ex i, universal Transmitter options Transmitter, enter complete setting in plain text (Y11:+/-NNNN... +/-NNNN C,F) Enter measuring point (max. 8 characters) in plain text Transmitter, enter measuring point description (max. 16 characters) in plain text Transmitter, enter measuring point text (max. 3 characters) in plain text Transmitter, enter bus address in plain text Transmitter, fail-safe value 3.6 ma (instead of.8 ma) Transmitter with a SIL conformity Transmitter with a SIL /3 conformity Transmitter test protocol (5 points) Other cable gland (only for connection head) Polyamide for cable diameter mm ( inch) Stainless steel for cable diameter 3 6,5 mm ( inch) Device plug M1 x 1 Order code T10 T11 T0 T1 T30 T31 T40 T41 T45 T46 Y11 Y17 Y3 Y4 Y5 U36 C0 C3 C11 K0 K03 K11 Deviating pipe; mm (inch) Collar size; mm (inch) ( ) 50 x 35 (1.97 x 1.38) S ( ) 70 x 70 (.76 x.76) S (1.5.4) 90 x 85 (3.54 x 3.35) S13 Larger nominal diameters on request S19 Space-saving mounting (latch fastening) Outer pipe; mm (inch): ( ) S ( ) S (Clamping band version recommended, see below) ( ) S3 (Clamping band version recommended, see below) Clamping band installation Outer pipe; mm (inch): ( ) S ( ) S3 Without clamping band S35 Selection and Ordering data Further Options Assignment marking, engraving instead of adhesive label (Serial number and pipe diameter on plug and plastic block) L11 mm drain hole L1 Sensor 4-wire connection L14 Heat-conductive-compound, silicone-free, syringe 3 g L15 Suffixes Add "-Z" to Article No. and specify Order code and plain text. TAG plate made of stainless steel (specify TAG No. in plain Y15 text) Test report at 0 %, 50 % and 100 % (specify the measuring Y33 range in plain text) If optional head transmitters are integrated, please note that all calibration points are located in the set measuring range. If the points are located outside the standard measuring range, a Y01 addition is always required. Special version, specify in plain text Y98 Process number for special version Y99 Order code Accessories, see page /38. Ordering examples: Deviating tube diameter 8.5 mm: 7MC8016-1AZ00-Z K1Y+S1 {K1Y: 8.5 mm} Space-saving mounting, tube diameter 38 mm: 7MC8016-1AZ00-Z K1Y + S3 {K1Y: 38 mm}; as of diameter 18 mm, we recommend using the clamping band installation. Clamping band installation, tube diameter 111 mm: 7MC8016-1AZ00-Z K1Y+S3 {K1Y: 111 mm} Siemens FI /55

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

CombiTemp Temperature Measuring System

CombiTemp Temperature Measuring System CombiTemp Temperature Measuring ystem Flexible building block concept All wetted parts in acid-proof, stainless steel Pt or Pt sensors, - or -wire DIN A or B (/, /, /) elements ensor tubes Cable sensors

More information

FlexBar HRT Pressure Transmitter

FlexBar HRT Pressure Transmitter FlexBar HRT Pressure Transmitter 4...0 ma, -wire transmitter, HART communication Some hygienic connections conform to -A standards, FDA demands and EHEDG guidelines Configurable span, unit and damping

More information

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

Adapter system for measuring instruments with G1 hygienic connection Model process adapter Accessories Adapter system for measuring instruments with G1 hygienic connection Model 910.61 process adapter WIKA data sheet AC 09.20 Applications Food, beverage and pharmaceutical industry Cosmetics

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

OPTISWITCH 6600 C Technical Datasheet

OPTISWITCH 6600 C Technical Datasheet Technical Datasheet Microwave Level Switch for standard hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE CONTENTS

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement from plant vibration

More information

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor.   Operating Instructions: EN. EN/2017-04-03 Design and specifications subject to change without notice English page 1 8 Field of application CombiTemp TFRx is a temperature sensor, based on RTD technology, which is designed and produced

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of

More information

Threaded resistance thermometer Miniature design Model TR10-D

Threaded resistance thermometer Miniature design Model TR10-D Temperature Threaded resistance thermometer Miniature design Model TR10-D WIKA data sheet TE 60.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion

More information

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Resistance thermometer With spring-loaded tip Model TR55

Resistance thermometer With spring-loaded tip Model TR55 Temperature Resistance thermometer With spring-loaded tip Model TR55 WIKA data sheet TE 60.55 for further approvals see page 2 Applications Bearing temperature measurement on: Pumps Gears Motors Special

More information

LS 5000 series Vibration Level Switch for liquids

LS 5000 series Vibration Level Switch for liquids Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview for flexible and cost-effective temperature measurements Supports the standard (HART V 7.1) Very high security level for wireless data transmission Built-in local user interface (LUI) with -button

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS THERMOWELL & REPLACEABLE GENERAL PURPOSE PT100CB/TP C20 C21 C24 C26-1 1 C26-2 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded

More information

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS Pressure transmitter/pressure switch PASCAL CS for food/pharmaceutical/biotechnology,type series CS2110 Features Multifunctional pressure transmitter/pressure switch Hygienic case with no notches or indentations

More information

Gas-actuated thermometer Stainless steel version Model 73

Gas-actuated thermometer Stainless steel version Model 73 Temperature Gas-actuated thermometer Stainless steel version Model 73 WIKA data sheet TM 73.01 for further approvals see page 15 Applications General process instrumentation in the chemical and petrochemical

More information

Temperature Measurement Product overview

Temperature Measurement Product overview Siemens AG 017 Product overview Overview Type Description Page Software for parameterization Temperature sensors TS100 Cable connection Universal use For unfavorable space conditions /40 - Mineral-insulated

More information

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/ 468 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 Temperature probe a Temperature probes TP series TP series Highest possible flexibility A temperature probe has to be flexible and

More information

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2-16; P=87 PSI Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,

More information

Pressure transmitter PASCAL CV,

Pressure transmitter PASCAL CV, Pressure transmitter PASCAL CV, for food/pharmaceutical/biotechnology, Type series CV311.-..-K Features Modular pressure transmitter Output signal: - 4 20 ma - HART protocol (rev. 6), option - PROFIBUS

More information

Model VDL 115 Vacuum drying chambers for flammable solvents

Model VDL 115 Vacuum drying chambers for flammable solvents Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Flowmeter SITRANS FC40 Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement

More information

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H Level measurement Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H KSR data sheet FFG-P, FFG-T, FFG-TP, FLM-H Applications High-accuracy level measurement

More information

Rosemount 0085 Pipe Clamp Sensor

Rosemount 0085 Pipe Clamp Sensor Product Data Sheet Rosemount Pipe Clamp Sensor Rosemount 0085 Pipe Clamp Sensor Non-intrusive design for fast and easy temperature measurement in piping applications Platinum RTD Temperature Sensors with

More information

Pressure transmitter/pressure switch PASCAL CS

Pressure transmitter/pressure switch PASCAL CS Pressure transmitter/pressure switch PASCAL CS for food/pharmaceutical/biotechnology, Type series CS2110 Features Multifunctional pressure transmitter/pressure switch Hygienic case with no notches or indentations

More information

Thermowell for Screwing

Thermowell for Screwing Accessories - KC0126-2013/09 Thermowell for Screwing Nominal pressure PN160. Inner bore diameter 9 mm. WT70 C 01 Temperature cylindrical thermowell for screwing, PN160 V900 9 Z01 M20x1. 5 P02 M27x2 Code

More information

Thermal Mass Flowmeter Sensyflow FMT200-D

Thermal Mass Flowmeter Sensyflow FMT200-D Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring

More information

Resistance thermometer For additional thermowell Model TR10-B

Resistance thermometer For additional thermowell Model TR10-B Temperature Resistance thermometer For additional thermowell Model TR10-B WIKA data sheet TE 60.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

Precision temperature control/sensing

Precision temperature control/sensing PROBE TEMPERATURE SENSORS TE200 Series Precision temperature control/sensing FEATURES: Thermistor or Precision RTD Various configurations available Selection of enclosures Custom laser etching available

More information

Prosonic T FMU30. Technical Information

Prosonic T FMU30. Technical Information Technical Information Prosonic T FMU30 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids, pastes and coarse bulk materials Application Continuous, non-contact

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.

More information

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transducers Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam

More information

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 ) The flow meter is based on the thermal mass flow measurement and is ideal for measuring the flow of compressed air and gases in pipes from DN50 (2 ) to DN700 (28 ). With the, the consumption of compressed

More information

Threaded resistance thermometer With protection tube Model TR10-C

Threaded resistance thermometer With protection tube Model TR10-C Temperature Threaded resistance thermometer With protection tube Model TR10-C WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information

Model VD 23 Vacuum drying chambers for non-flammable solvents

Model VD 23 Vacuum drying chambers for non-flammable solvents Model VD 23 Vacuum drying chambers for non-flammable solvents A BINDER vacuum drying oven VD series gently dries materials with homogeneous temperature distribution. The patented expansion shelf technology

More information

Ideal protection for your electrics: häwa cable ducts

Ideal protection for your electrics: häwa cable ducts Ideal protection for your electrics: häwa cable ducts Well Conceived The häwa group has established itself as an innovative and highly competent supplier to machinery and facility equipment companies in

More information

LS 6600 Technical Datasheet

LS 6600 Technical Datasheet Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301

More information

KF ADAPTORS AND BELLOWS

KF ADAPTORS AND BELLOWS GENERAL INFORMATION Various adaptors and bellows are used for glass pipelines to form joints with other pipelines or with tubes. Especially for forming joints with fixed pipelines or in certain cases between

More information

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter Main features Range from 500 µs/cm to 1000 ms/cm ll hygienic design Built in graphical display CombiView DFON Very fast temperature compensation Easy and full programmable with FlexProgrammer 9701 FI5

More information

Standard Temperature Sensors for Industrial Use

Standard Temperature Sensors for Industrial Use Standard Temperature Sensors for Industrial Use Description of Temperature Sensors Design and fabrication of our industrial sensors correspond with the technical standard of DI 4770. Our sensors can be

More information

Temperature sensors and accessories for heat and cooling measurement points

Temperature sensors and accessories for heat and cooling measurement points Temperature sensors and accessories for heat and cooling measurement points Applications Temperature sensors are metrological components for heat or cold measuring points. They are used in pairs and measure

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Made to measure. Since PASCAL Ci4. The intuitive pressure and differential pressure transmitter meeting highest standards.

Made to measure. Since PASCAL Ci4. The intuitive pressure and differential pressure transmitter meeting highest standards. Made to measure. Since 1968. PASCAL Ci4 The intuitive pressure and differential pressure transmitter meeting highest standards Process industry PASCAL Ci4 - High-resolution graphic display - Intuitive

More information

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and

More information

Threaded resistance thermometer Model TR10-C, with protection tube

Threaded resistance thermometer Model TR10-C, with protection tube Electrical temperature measurement Threaded resistance thermometer Model TR10-C, with protection tube WIKA data sheet TE 60.03 for further approvals see page 2 Applications Machine building, plant and

More information

Thermocouples Model TC200, for Additional Thermowell

Thermocouples Model TC200, for Additional Thermowell Electrical Temperature Measurement Thermocouples Model TC200, for Additional Thermowell WIKA Data Sheet TE 65.10 Applications T Machinery, plant and tank construction T Energy and power plant technology

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage. Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text

More information

selection of special materials is available to handle almost any fluid.

selection of special materials is available to handle almost any fluid. For Pressure Transmitters and Bourdon Tube Pressure Gauges Types 839 X Chemical Seals for Various Applications Advantages / Benefits Separation of medium and measuring device in difficult applications

More information

FlexBar 3501 Pressure Transmitter

FlexBar 3501 Pressure Transmitter FlexBar 350 Pressure Transmitter 4...0 ma, -wire transmitter, HART communication (Optional) Stainless steel heavy duty housing with LC-Display (Optional) Configurable span, unit, damping and linearisation

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

Magnetic float switch For vertical installation Model FLS

Magnetic float switch For vertical installation Model FLS Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Temperature sensors from ifm. Selection guide

Temperature sensors from ifm. Selection guide Temperature sensors from ifm. Selection guide Temperature sensors www.ifm.com/us WARRANTY years on ifm products Systems for temperature monitoring The optimum solution for every requirement Compact temperature

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

Technical Information itherm TM411

Technical Information itherm TM411 TI01038T/09/EN/05.15 71306162 Products Solutions Services Technical Information itherm TM411 Trend-setting, modular resistance thermometer for hygienic and aseptic applications Easy-to-use metric version

More information

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45

More information

TMT470L Temperature Transmitter

TMT470L Temperature Transmitter Technical information TMT470L Temperature Transmitter OEM components for compact thermometer/cable transmitter. 2/3 or 4-wire Pt100 can be connected. 4 to 20 ma transmitter, programmable via PC. Application

More information

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing Vane wheel probe BFA25 for flow measurement of gases and liquids with egrated, configurable transducer UFA in Ex-d housing Drawing 5 Vane wheel flow probe BFA25 (Dimensions see Page 3) Measurable variables

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R 13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal

More information

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A

HYGROPHIL-F, Moisture Analyzer, Type , -11, -12, -13 series A HYGROPHIL-F, Moisture Analyzer, Type 5673-10, -11, -12, -13 series A Moisture Measurement in gases and liquids Combined moisture and temperature sensor Multiple channel analyzer, max. 3 sensors can be

More information

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215 HERZ STRÖMAX 7GM/GML/GR HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0 H Rp L SW L L Dimensions in mm

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

Linear Luminaire with LED Series 6412/5

Linear Luminaire with LED Series 6412/5 > For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

KF ADAPTORS AND BELLOWS

KF ADAPTORS AND BELLOWS GENERAL INFORMATION Various adaptors and bellows are used for glass pipelines to form joints with other pipelines or with tubes. Bellows are even provided for forming joints with main pipelines or sometimes

More information

CABLE ENTRY SYSTEM KDSClick

CABLE ENTRY SYSTEM KDSClick CABLE ENTRY SYSTEM KDSClick PRODUCT INFORMATION Cable entry system KDSClick CONTA-CONNECT TURNING CABLES INSIDE OUT! a revolutionary cable entry system! Fast. Safe. Very simple. Our KDSClick cable entry

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

Product information Ultrasonic

Product information Ultrasonic Product information Ultrasonic Level measurement in liquids and bulk solids VEGASON 6 VEGASON 6 VEGASON 6 Document ID: 90 Contents Contents Measuring principle... Type overview... 4 Instrument selection...

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,

More information

E Q U I C I E N H Y G E U R O P E A N

E Q U I C I E N H Y G E U R O P E A N PRESSURE AND LEVEL TRANSMITTERS ALL STAINLESS SERIES 8000-SAN OUTPUT 4-20 ma / 2-WIRE ZERO AND SPAN ADJUSTABLE ALL FORMS OF HYGIENIC/ SANITARY CONNECTIONS AVAILABLE VERY STRONG FLUSH MOUNTING DIAPHRAGM

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start

SITRANS F Coriolis Flowmeters SITRANS FCT030 transmitter Quick Start SITRANS F Coriolis Flowmeters Quick Start Before installing, including in hazardous areas, refer to the Operating Instructions on the internet or on the SITRANS F literature CD-ROM. They contain detailed

More information

LS series. Electrical Position Indicators for Quarter Turn Actuators

LS series. Electrical Position Indicators for Quarter Turn Actuators 0 Electrical Position ndicators for Quarter Turn Actuators Construction The GEMÜ electrical position indicators are used to indicate and monitor the position of quarter turn valves. Depending on the version,

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

Level sensor for monitoring the level of liquid media

Level sensor for monitoring the level of liquid media Level sensor MG Level sensor for monitoring the level of liquid media Characteristics Level sensor output 4 20mA or Resistance output in three-wire potentiometer circuit Temperature range: -30 C to 150

More information

Inductive Conductivity Meter ILM

Inductive Conductivity Meter ILM SENSORS FOR FOOD AND BIOPHARMA. Product Information ILM-4 FOOD Inductive Conductivity Meter ILM Application/Specified Usage Inductive measurement of the specific conductivity of liquid media in the range

More information

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75 Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded

More information

Specification Sheet (Ref XXXXXX)

Specification Sheet (Ref XXXXXX) Retractex B M Specification Sheet (Ref 243275-XXXXXX) The retractable armature Retractex B M was designed for sanitary applications in biotechnology, food, beverage and pharmaceutical industry. The compact

More information

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC

More information

Level limit switch Series RF 3000 Selection list. Overview 2

Level limit switch Series RF 3000 Selection list. Overview 2 Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------

More information