INDOOR POINT ID INTRUSION SYSTEM P RODUCT CATALOGUE
|
|
- Adelia Blankenship
- 5 years ago
- Views:
Transcription
1 INDOOR POINT ID INTRUSION SYSTEM P RODUCT CATALOGUE
2 3 LINEA INDEX PREMISE...5 SENSORS XS-DOOR SN-XS-DR Piezodynamic sensor for doors and windows... 6 XS-GRID MD-XS-GR Detection module for the protection metal grates... 7 ELECTONIC BOARDS BR-XS-PU Interface peripheral board for SERIE A03 sensors... 8 BR-XS-CTRL32 Controller board for the management of 32 sensors... 9 BR-XS-CTRL64 Controller board for the management of 64 sensors BR-XS-CTRL128 Controller board for the management of 128 sensors BR-XS-RE16L 16-relay expansion board for BR-XS-CTRL32/ BR-XS-RE16 16-relay expansion board for BR-XS-CTRL ACCESSORIES AND SPARE PARTS SN-XS-GR Piezodynamic sensor for metal grates BR-XS-GR Analysis board SB-XS-DR Base for XS-DOOR sensors MB-XS-DR Spacer for XS-DOOR magnets CB-XS connection cable MS-XS Flexible metal conduit for connection cable protection APPLICATION EXAMPLE...17 PRICE LIST...20 INSTRUCTIONS...21 GENERAL SALES CONDITIONS...22
3 5 LINEA PREMISE is an intrusion detection system which has moved into the world of indoor security houses, offices, banks and businesses the same technologies developed by DEA Security for the outdoor perimeter protection of high risk compounds such as airports and power plants. Among those technologies we can mention the identification of each sensor under alarm (Point ID), the sensor self-test, the centralization of the alarm signals and the remote management of the system over IP. Currently product line is composed of two different families of piezoelectric sensors: XS-DOOR, for the protection of doors, windows and skylights, and XS-GRID, for the protection of metal grates. XS-DOOR sensors detect shocks, breakthrough and opening events, whilst XS-GRID sensors detect shocks, breakthrough and cut. The latter have been designed for outdoor use, therefore they are equipped with a heavy-duty housing and with cable protected with flexible metal conduit. sensors are all addressable, therefore they are unequivocally identified; they contain a piezoceramic transducer, which is a virtually inexhaustible device which combines superior detection capability and very high tolerance towards environmental disturbances. The detectors communicate with the XS-CTRL Controller boards: the most powerful of them can manage up to 128 sensors on two independent communication buses, 64 sensors per bus. These boards allow you to easily configure and monitor even the most complex systems: both from a locally connected PC (USB) and from remote station (Ethernet or Wi-Fi*) you can calibrate and program sensors, view their status and the alarm signals, monitor their operating parameters and the link quality. The sensors must be connected in series, but very soon a star connection will be possible using the XS-HUB device: this will simplify the cabling of systems distributed on different sections or floors of a building. can integrate other devices using XS-PU interface peripheral board: as a matter of fact the system can also employ SERIE A03 detectors and manage the alarm signals coming from third-party devices equipped with dry contacts. * An access point or a Wi-Fi router are needed.
4 SENSORS SENSORS XS-DOOR sensor for doors and windows Part number SN-XS-DR Point ID piezodynamic sensor for the protection of windows and doors against shocks, breakthrough and opening. The model providing the opening detection employs an electronic magnetic sensor with anti-masking function. The sensor can be provided with either a thicker or a thinner mounting base: the former is compatible with the use of flexible metal conduit wrapping the connection cable. Part number MD-XS-GR SENSORS XS-GRID module for grates Module for the protection of metal grates against cut (continuous vibrations), shock (weak impacts) and breakthrough (strong impacts). It is composed of SN-XS-GR piezoceramic sensor and BR-XS-GR addressable interface peripheral board. The sensor is equipped with 1,5 metres of cable wrapped with flexible metal conduit. SENSORS 6 Compliance: Security grading: designed in accordance to Grade 3 (CLC/TS ) Environmental classification: designed in accordance to Class II (CLC/TS ) SN-XS-DRL sensor dimensions: 85x28x29 mm (LxHxW) SN-XS-DRH sensor dimensions: 85x33x29 mm (LxHxW) Magnet dimensions (without spacer): 83x15x15 mm (LxHxW) Packaging dimensions: 110x35x110 mm (LxHxW) Gross weight: SN-XS-DRL: 96 g SN-XS-DRLM: 114 g SN-XS-DRH: 100 g SN-XS-DRHM: 116 g Case material: self-extinguishing ABS IP Rating: IP40 Colour: white or grey Power supply: 12Vdc powered by Bus Current: 4 ma (max) Removal tamper Sensor thermal tamper detection Electronic magnetic sensor with anti-masking function Self-test function RGB status LED Inputs: bus 2 triple-balanced lines No of devices managed: 2 third-party sensors with C/NC relay contact Configuration and programming through Controller board Detection capability for single sensor: structures up to 4 m² (2x2 m) (*) Operating air gap magnet/sensor: 6 12 mm (**) (*) It may vary according to the dimensions and the type of structure.. (**) For models SN-XS-DRLM and SN-XS-DRHM. SN-XS-DR sensors must be connected to BR-XS-CTRL32, BR-XS-CTRL64 or BR-XS-CTRL128 Controller boards through Bus. The connection is carried out by means of CB- XS cable. The maximum distance between the Controller board and the last sensor of a bus is 500 metres. The sensors provided with thinner base are available in white colour only, whilst the ones with thicker base are available in grey colour only. However, thinner bases in grey colour and thicker bases in white colour can be purchased as spare parts (please see section Accessories and spare parts) , Sensor with thinner base and magnet , Sensor with thicker base and magnet COLOUR SN-XS-DRL Piezodynamic sensor for doors and windows with thinner base WHITE SN-XS-DRLM Piezodynamic sensor for doors and windows with thinner base and magnet WHITE SN-XS-DRH Piezodynamic sensor for doors and windows with thicker base GREY SN-XS-DRHM Piezodynamic sensor for doors and windows with thicker base and magnet GREY Compliance: Security grading: designed in accordance to Grade 2 (CLC/TS ) Environmental Classification: SN-XS-GR: designed in accordance to Class III (CLC/TS ) BR-XS-GR: designed in accordance to Class II (CLC/TS ) Sensor dimensions: 33x17x75 mm (LxHxW) Sensor cable length: 1,5 m Analysis board dimensions (without base): 55x17x50 mm (LxHxW) Analysis board dimensions (with base): 61x32x56 mm (LxHxW) Packaging dimensions: 160x55x160 mm (LxHxW) Gross weight: 338 g Sensor case material: glass fibre reinforced nylon Analysis board case material: self-extinguishing ABS Colour: grey Power supply: 12 Vdc powered by Bus Current: 6 ma (max) Sensor IP Rating: IP64 Analysis board IP Rating: IP40 Opening tamper (analysis board case) Thermal tamper detection (sensor and analysis board) Thermal expansion digital filter Self-test function (sensor and analysis board) Inputs: bus SN-XS-GR sensor line 2 triple-balanced lines No of devices managed: 1 SN-XS-GR sensor 2 third-party sensors with C/NC relay contact Configuration and programming through Controller board Detection capability for single sensor: structures up to 4 m² (2x2 m) (*) (*) It may vary according to the dimensions, type and thickness of the protected structure. Even though SN-XS-GR sensor is designed for outdoor use, BR- XS-GR board must be installed indoors. BR-XS-GR must be connected to Bus using CB-XS cable. The distance between BR-XS-GR and SN-XS-GR must be no more than 3 metres Sensor SN-XS-GR ,5 Peripherical board BR-XS-GR COLOUR MD-XS-GR Detection module for the protection of metal grates GREY 32 7
5 Interface peripheral board Part number BR-XS-PU Interface peripheral board for the connection of SERIE A03 sensors or third-party devices to Bus. This board is equipped with a microprocessor analysis unit which processes the analog signals coming from the sensor and sends the alarm signals to the controller board. When used with SERIE A03 sensors, it replaces SE03N and SE04N processing boards. BR-XS-PU can discriminate shocks (weak impacts), breakthrough events (single strong impacts), and drilling (continuous vibrations); it is also equipped with opening tamper and thermal tamper electronic device. Compliance: Environmental Classification: designed in accordance to Class II (CLC/TS ) Analysis unit dimensions (without base): 55x17x50 mm (LxHxW) Analysis board dimensions (with base): 61x32x56 mm (LxHxW) Packaging dimensions: 110x35x110 mm (LxHxW) Gross weight: 104 g Analysis board case material: self-extinguishing ABS IP Rating: IP40 Colour: white Power supply: 12 Vdc powered by Bus Current: 6 ma (max) Opening Tamper (analysis board case) Thermal tamper detection (analysis board) Inputs: Bus SERIE A03 sensor-line 2 triple-balanced lines No of devices managed: 1 SERIE A03 sensor 2 third-party sensors with C/NC relay contact Configuration and programming through Controller board BR-XS-PU must be connected to Bus using CB-XS cable. The distance between BR-XS-PU and sensor must be no more than 3 metres. BR-XS-PU Interface peripheral board for SERIE A03 sensors 32 Controller board for the management of 32 sensors Part number BR-XS-CTRL32 Controller board which manages up to 32 sensors/peripheral devices. It has the function to supply power, check the operating status and receive signals from each device connected to the bus, store them in an internal memory making this information available through relay contacts, DEA NET proprietary network or IP network. The service software enables you to configure and remotely monitor all the sensors/peripheral devices and relay expansion boards (if any) connected to the Controller board. Compliance: Dimensions: 178x30x116 mm (LxHxW) Packaging dimensions: 235x70x170 mm (LxHxW) Gross weight: 296 g Case material: aluminium IP Rating: IP20 Power supply: 12 Vdc (+/-25%) Current: 0,5 A (max) Inputs: 4 digital opto-isolated NC state solid relay outputs: General intrusion alarm General tamper Power fail Sensor fail Bus link loss 8 programmable Auxiliary C/NC relay outputs: up to 64 on 4 BR-XS-RE16L expansion boards OC outputs: 2 programmable Communication ports: Ethernet (RJ45) USB DEA NET Bus BR-XS-RE16L Bus No of devices managed: up to 32 sensors/peripheral devices Calibrations and Configurations: using service software for MS Windows CPU processing capacity: 32 bits Digital memory: more than events Service software licence included BR-XS-CTRL32 must be installed inside a case protected against opening. BR-XS-PU and BR-XS-GR boards, when connected to BR-XS- CTRL32, are managed as sensors. BR-XS-CTRL32 can manage up to 2 BR-XS-RE16L expansion boards through dedicated communication interface. BR-XS-CTRL32 Controller board for the management of 32 sensors/peripheral devices 8 9
6 Controller board for the management of 64 sensors Part number BR-XS-CTRL64 Controller board which manages up to 64 sensors/peripheral devices. It has the function to supply power, check the operating status and receive signals from each device connected to the bus, store them in an internal memory making this information available through relay contacts, DEA NET proprietary network or IP network. The service software enables you to configure and remotely monitor all the sensors/peripheral devices and relay expansion boards (if any) connected to the Controller board. Compliance: Dimensions: 178x30x116 mm (LxHxW) Packaging dimensions: 235x70x170 mm (LxHxW) Gross weight: 296 g Case material: aluminium IP Rating: IP20 Power supply: 12 Vdc (+/-25%) Current: 0,5 A (max) Inputs: 4 digital opto-isolated NC state solid relay outputs: General intrusion alarm General tamper Power fail Sensor fail Bus link loss 8 programmable Auxiliary C/NC relay outputs: up to 96 on 6 BR-XS-RE16L expansion boards OC outputs: 2 programmable Communication ports: Ethernet (RJ45) USB DEA NET Bus BR-XS-RE16L Bus No of devices managed: up to 64 sensors/peripheral devices Calibrations and configurations: through service software for MS Windows CPU processing capacity: 32 bits Digital memory: more than events Service software licence included BR-XS-CTRL64 must be installed inside a case protected against opening. BR-XS-PU and BR-XS-GR boards, when connected to BR-XS- CTRL64, are managed as sensors. BR-XS-CTRL64 can manage up to 4 BR-XS-RE16L expansion boards through dedicated communication interface. BR-XS-CTRL64 Controller board for the management of 64 sensors/peripheral devices Controller board for the management of 128 sensors Part number BR-XS-CTRL128 Controller board which manages up to 128 sensors/peripheral devices. It has the function to supply power, check the operating status and receive signals from each device connected to the bus, store them in an internal memory making this information available through relay contacts, DEA NET proprietary network or IP network. The service software enables you to configure and remotely monitor all the sensors and relay expansion boards (if any) connected to the Controller board. Compliance: Dimensions: 205x41x160mm (LxHxW) Packaging dimensions: 235x70x170 mm (LxHxW) Gross weight: 715 g Case material: aluminium IP Rating: IP20 Power supply: 12 Vdc (+/-25%) Current: 1 A (max) Inputs: 8 digital opto-isolated NC state solid relay outputs: General intrusion alarm General tamper Power fail Sensor fail Bus link loss Auxiliary C/NC relay outputs: up to 128 on 8 BR-XS-RE16 expansion boards OC outputs: 3 programmable Communication ports: Ethernet (RJ45) USB DEA NET Bus BR-XS-RE16 Bus 1 Bus 2 Bus No of devices managed: up to 128 sensors/peripheral devices (64 each bus) Calibrations and Configurations: through service software for MS Windows CPU processing capacity: 32 bits Digital memory: more than events Service software licence included BR-XS-CTRL128 must be installed inside a case protected against opening. BR-XS-PU and BR-XS-GR boards, when connected to BR-XS- CTRL128, are managed as sensors. BR-XS-CTRL128 can manage up to 8 BR-XS-RE16 expansion boards through dedicated bus. BR-XS-CTRL128 Controller board for the management of 128 sensors/peripheral devices 10 11
7 12 16-relay expansion board for BR-XS-CTRL32/64 Part number BR-XS-RE16L 16-relay expansion board to make the alarm signals available through C/NC contacts. All the relay outputs can be programmed via software from BR-XS-CTRL32 or BR-XS-CTRL64 Controller boards. Compliance (if connected to BR-XS-CTRL32 or BR-XS-CTRL64): Power supply: from BR-XS-CTRL32/64 Current: 30 ma (max) Operating temperature: C Board dimensions: 110x61 mm (BxH) Mounting plate dimensions: 130x64 mm (BxH) Packaging dimensions: 145x67x70 mm (LxHxW) Gross weight: 78 g C/NC relay outputs: 16-relay outputs programmable from Controller board Connection to BR-XS-CTRL32 and BR-XS-CTRL64 by flat cable BR-XS-RE16L works with BR-XS-CTRL32 and BR-XS-CTRL64 Controller boards only. The board must be installed inside a case protected against opening. BR-XS-RE16L 16-relay expansion board for BR-XS-CTRL128 Part number BR-XS-RE16 16-relay expansion board to make the alarm signals available through C/NC contacts. All the relay outputs can be programmed via software from BR-XS-CTRL128. Compliance (if connected to BR-XS-CTRL128): Power supply: 12 Vdc (+/-25%) Current: 50 ma (standby) 220 ma (max) Operating temperature: C Board dimensions: 155x85 mm (BxH) Mounting plate dimensions: 175x89 mm (BxH) Packaging dimensions: 0x50x96 mm (LxHxW) Gross weight: 280 g C/NC/NO relay outputs: 16-relay outputs programmable from Controller board Connection to BR-XS-CTRL128 by dedicated bus Connection to DEA NET bus BR-XS-RE16 works with BR-XS-CTRL128 Controller board only. The board must be installed inside a case protected against opening. BR-XS-RE16 16-relay expansion board for BR-XS-CTRL32 and BR-XS-CTRL64 16-relay expansion board for BR-XS-CTRL128 ACCESSORIES and SPARE PARTS XS-GRID sensor Part number SN-XS-GR Piezoceramic passive sensor which protects metal grates against shock, cut and breakthrough. Designed for outdoor use, the sensor is protected by a reinforced polyammide housing and the connection cable is wrapped with flexible metal conduit. SN-XS-GR must be connected to BR-XS-GR analysis board, which processes the signals coming from the sensor and sends the alarm signals (if any) to the Controller board. Compliance (if connected to BR-XS-GR): Security grading (if connected to BR-XS-GR): designed in accordance to Grade 2 (CLC/TS ) Environmental class: designed in accordance to Class III (CLC/TS ) Sensor dimensions: 33x17x75 mm (LxHxW) Cable length (wrapped with flexible metal conduit): 1,5 m Gross weight: 210 g Case material: glass fibre reinforced nylon Colour: grey IP rating: IP64 Self-test function (if connected to BR-XS-GR) Connections: 3 wires Detection capability for each sensor: structures up to 4 m² (2x2 m) (*) (*) It may vary according to the dimensions, the type and the thickness of the protected structure. SN-XS-GR must be connected to BR-XS-GR analysis board. The distance between BR-XS-GR and SN-XS-GR must be no more than 3 metres COLOUR SN-XS-GR Piezoceramic sensor for metal grates GREY ACCESSORIES and SPARE PARTS 13
8 ACCESSORIES and SPARE PARTS ACCESSORIES and SPARE PARTS XS-GRID analysis board Part number BR-XS-GR Microprocessor analysis board for SN-XS-GR sensors. It processes the analog signals coming from SN-XS-GR sensor and sends the alarm signals (if any) to the Controller board through Bus. BR-XS-GR can discriminate between cut (continuous vibrations), shock (weak impacts) and breakthrough (strong impacts); it also allows filtering nuisance alarms due to thermal expansion of the metal structure. Compliance (if connected to SN-XS-GR): Security grading (if connected to SN-XS-GR): designed in accordance to Grade 2 (CLC/TS ) Environmental Class: designed in accordance to Class II (CLC/TS ) Analysis board dimensions (without base): 55x17x50 mm (LxHxW) Analysis board dimensions (with base): 61x32x56 mm (LxHxW) Packaging dimensions: 110x35x110 (LxHxW) Gross weight: 104 g (CONTROLLARE IL PESO) Analysis board case material: self-extinguishing ABS IP rating: IP40 Colour: grey Power supply: 12 Vdc through Bus Current: 6 ma (max) Opening tamper (analysis board case) Thermal tamper detection (analysis board and SN-XS-GR sensor) Thermal expansion digital filter Self-test function (analysis board and SN-XS-GR sensor) Inputs: Bus SN-XS-GR sensor line 2 triple-balanced lines No of devices managed: 1 SN-XS-GR sensor 2 third-party sensors with C/NC contacts Configuration and programming from Controller board ,5 32 ACCESSORIES and SPARE PARTS Base for XS-DOOR sensors Part number SB-XS-DR Thinner or thicker base to be used with XS-DOOR sensors. It is supplied in a pack containing 4 single colour pieces. SB-XS-DRL base dimensions: 85x8x29 mm (LxHxW) SB-XS-DRH base dimensions: 85x13x29 mm (LxHxW) SB-XS-DRL packaging gross weight: 8 g SB-XS-DRH packaging gross weight: 10 g Material: self-extinguishing ABS Colour: white or grey The thicker bases allow the use of MS-XS-25 flexible metal conduit to protect the connection cable. PACK COLOUR SB-XS-DRLG Thinner bases for XS-DOOR sensors 4 pieces GREY SB-XS-DRLW Thinner bases for XS-DOOR sensors 4 pieces WHITE SB-XS-DRHG Thicker bases for XS-DOOR sensors 4 pieces GREY SB-XS-DRHW Thicker bases for XS-DOOR sensors 4 pieces WHITE Spacer for XS-DOOR magnets Part number MB-XS-DR Spacer to be used with the magnets of SN-XS-DRLM and XS-DRHM sensors. It is supplied in a pack containing 4 single colour pieces. Dimensions: 83x5x15 mm (LxHxW) Packaging gross weight: 4,3 g Material: self-extinguishing ABS Colour: white or grey ACCESSORIES and SPARE PARTS BR-XS-GR must be connected to BR-XS-CTRL32, BR-XS-CTRL64 or BR-XS-CTRL128 Controller boards using Bus that provides both data and power connections in one cable. The distance between BR-XS-GR and SN-XS-GR must not be more than 3 metres. BR-XS-GR Analysis board for XS-GRID sensors It is possible to use one or more spacers to install the magnet at the same height as the sensor. PACK COLOUR MB-XS-DRG Spacers for XS-DOOR magnets 4 pieces GREY MB-XS-DRW Spacers for XS-DOOR magnets 4 pieces WHITE 14 15
9 ACCESSORIES and SPARE PARTS 16 ACCESSORIES and SPARE PARTS Connection cable for sensors Part number CB-XS 4-wire shielded cable for the connection of sensors/peripheral devices to BR-XS-CTRL32, BR-XS-CTRL64 and BR-XS-CTRL128 Controller boards. Compliance: CEI 20-11, CEI-UNEL 36762, EN 50363, CEI II, EN IEC , CEI 20-35, IEC , 2014/35/EU, RoHS 2011/65/EU, 2002/95/EC Gross weight: CB-XS-100: 4,5 kg CB-XS-200: 9 kg Diameter: 4,80 ± 0,2 mm Wires: two twisted bare copper pairs Cross sectional area: 0,50 mm² (power supply) 0,22 mm² (data) Operating temperature: C Short circuit temperature: max 150 C Insulation voltage: 0,6/1 kv Maximum working voltage: 50Vac; 120Vdc Wire insulation material: flame retardant PVC Outer jacket material: flame retardant PVC Bending radius: 15 times outer diameter Use: this cable can be installed in a group of cables with max operating voltage of Uo/U 0.6/1 kv Colour: white CB-XS connection cable is available in 100m and 200m hanks. Flexible metal sheath for SN-XS-DR sensors Part number MS-XS Flexible metal conduit for the protection of the connection cable of SN-XS-DR sensors equipped with thicker base. It is made of galvanized steel with single seam, PVC vacuum covered. Dimensions: 7 x 10 mm (Ø int. x Ø ext.), 1/4 Gross weight: 2,45 kg Bending radius: 25 mm Operating temperature: C Colour: grey The length of CB-XS cable connecting a sensor to the relevant Controller board cannot be more than 500 metres COLOUR CB-XS-100 connection cable 100 m hank WHITE CB-XS-200 connection cable 200 m hank WHITE MS-XS metal conduit must be used with SN-XS-DRH and SN- XS-DRHM sensors. If you have SN-XS-DRL or SN-XS-DRLM models (equipped with thinner base), the thicker base can be purchased as spare part (please see SB-XS-DR). The metal conduit is available in 25 m hanks. LENGTH (m) COLOUR MS-XS-25 Flexible metal sheath for CB-XS cable 25 GREY APPLICATION EXAMPLE APPLICATION EXAMPLE APPLICATION EXAMPLE 17
10 APPLICATION EXAMPLE APPLICATION EXAMPLE Typical configuration of the system MD-XS-GR SN-XS-DRLM SN-XS-DRL SN-XS-DRLM XS-DOOR sensor for DOORS and WINDOWS XS-GRID module for GRATES BR-XS-CTRL128 BR-XS-RE16 BR-XS-RE16 Alarm control panel bus 1 APPLICATION EXAMPLE Example of protection of a commercial building Protection of a single-storey commercial building. Below you can find a list of the structures to be protected and the intrusion sensors to be used. STRUCTURE TO BE PROTECTED SOLUTION 2 single front doors 1 XS-DOOR sensor with magnetic contact on each door 1 double emergency exit door 1 XS-DOOR sensor with magnetic contact 8 openable windows without grate 1 XS-DOOR sensor with magnetic contact on each window 5 non-openable windows without grate 1 XS-DOOR sensor on each window 2 windows equipped with grate 1 XS-GRID module on each grate 2 glass windows of 6 m² each 2 SERIE A03 glass-break sensors on each glass window 2 walls of approx. 12 m each 4 SERIE A03 sensors on each wall Bill of quantity for the execution of the system as in the example above: APPLICATION EXAMPLE bus 2 DEA NET Ethernet Q.TÀ 11 SN-XS-DRHM Piezodynamic sensors for doors and windows with thicker base and magnet 5 SN-XS-DRH Piezodynamic sensors for doors and windows with thicker base Supervision system 2 MD-XS-GR Detection module for the protection of grates 4 SERIE A03 for glasses SERIE A03 glass-break piezoceramic sensors 8 SERIE A03 for walls SERIE A03 piezodynamic sensors for walls 12 BR-XS-PU Interface peripheral boards 1 BR-XS-CTRL32 Controller boards for the management of 32 sensors BR-XS-PU BR-XS-PU BR-XS-PU BR-XS-PU BR-XS-PU 2 BR-XS-RE16L 16-relay expansion board for BR-XS-CTRL32 SERIE A03 for WINDOWS and DOORS SERIE A03 for WINDOWS and DOORS with MAGNET SERIE A03 for GLASSES SERIE A03 for GRATES SERIE A03 for WALLS 18
11 INSTRUCTIONS 20 INSTRUCTIONS for the use and installation of intrusion detection system perimeter intrusion detection system consists of a wide range of shock sensors for the protection of doors, windows, glass doors and windows, metal grates and walls. The sensors perceive the shocks (single or repeated) and the vibrations due to an attack to the physical barrier to which they are installed (for example a door or a window) following an intrusion attempt, either real or simulated. Thanks to sophisticated analysis algorithms, system offers a very high tolerance to environmental nuisances and superior detection capability. The operating parameters of each sensor can be set by the professional installer which can choose the desidered protection level. As a matter of fact, the installer can adjust the sensitivity of the sensor and its detection capability (security level) to obtain the best performance on the specific protected structure/surface. The detection capability of system, in its several applications, depends not only on the settings but also on the installation conditions. As a matter of fact the performance of the sensor varies according to the dimensions, the thickness and the material of the protected surface/ structure. For this reason you should always check the correct functioning of the system by simulating the impacts which are to be detected and by adjusting the sensitivity and the security level of each single sensor accordingly. The detection capability of system can be set by the professional installer up to very high levels in order to perceive and detect very sophisticated attack methods which are carried out with great care. To the maximum sensitivity the capability of system to discriminate environmental nuisances may however decrease and consequently improper alarms may be triggered following to impacts or vibrations not due to a real intrusion attempt and also occurred outside of the protected area DEA Security S.r.l. edition January v DEA Security S.r.l. reserve the right to vary at any moment and without notice the information and the technical features herein. All trademarks mentioned herein belong to their owners. Third-party brands, product names, trade names, corporate names and company names mentioned may be trademarks of their respective owners or registered trademarks of other companies and are used for purposes of explanation and to the owner's benefit, without implying a violation of copyright law. 21
12 DEA Security S.r.l. Via Bolano, snc Santo Stefano di Magra (SP) tel fax VAT NO.: IT dea@deasecurity.com
perimeter protection systems TORSUS Informative Note TORSUS system - edition March v
perimeter protection systems TORSUS perimeter intrusion detection system for rigid metal fences Informative Note TORSUS system - edition March 2012 - v. 1.0.1 Perimeter intrusion detection systems Perimeter
More informationSISMA CA. Intrusion detection system for concrete flooring. Informative Brochure
SISMA CA Intrusion detection system for concrete flooring Informative Brochure 2 Contents Perimeter intrusion detection systems... 5 1. SISMA CA system... 7 1.1 The components of the system... 8 1.1 1
More informationPRODUCT INFORMATION. UNITRONIC LiYY. Info The classic for multi-functional use Further dimensions/colours on request
Data transmission cable with colour code acc. to DIN 47100 : Low-frequency PVC data cable DIN47100 coded Flexible (0.34mm² multi-wire Maxi TERMI-POINT ) Flame retardant, Instrumentation Control Automation
More informationSR B series coded magnetic safety sensors
SR B series coded magnetic safety sensors Selection diagram CONTACTS 0 NC NC+NO NC+NO Contact states are displayed for closed guard SENSOR ACTUATOR OUTPUT TYPE SM B0F Actuation distance mm SM B0F Actuation
More informationÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V
PRODUCT INFORMATION Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: Article number choice
More informationSingle-Core PVC 6491X
Single-Core PVC X 0/0 V Application PVC insulated only cable for fixed wiring purposes. Used in trunking or conduit, or may be surface mounted when used for earthing. Specifications In accordance with
More informationSR A series coded magnetic safety sensor
SR A series coded magnetic safety sensor Selection diagram CONTACTS 0 +NO NC+NO Contact states are displayed for closed guard ACTUATOR SENSOR SM A0N Actuation distance 5 mm OUTPUT TYPE SR AD N PVC cable
More informationScreened highly flexible data transmission cable with PUR outer sheath and twisted pairs - UL/CSA-listed
Screened highly flexible data transmission cable with PUR outer sheath and twisted pairs - UL/CSA-listed : Low-frequency PUR data cable UL AWM CMX VW-1 Halogen-free, Highly flexible Drag chain, Screened
More informationRXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station
s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.
More informationTECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5
page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:
More informationCATALOGUE D45 High performance door entry system
CATALOGUE 2011 D45 High performance door entry system 2 INDEX General features 4 Devices 10 Software 18-19 Solution for multi-storey buildings 20 Solution for a building complex 21-22 Compatibility with
More informationD45. High performance door entry system CATALOGUE A Group Brand
D45 CATALOGUE 2011 High performance door entry system A Group Brand 2 INDEX General features 4 Devices 10 Software 18-19 Solution for multi-storey buildings 20 Solution for a building complex 21-22 Compatibility
More informationSensitive Earth-fault Relay SPAJ 111 C. Product Guide
Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent
More informationINTRUSION DETECTION SYSTEM FOR METAL FENCES I NFORMATIVE BROCHURE
SERIR P 2P INTRUSION DETECTION SYSTEM FOR METAL FENCES I NFORMATIVE BROCHURE 3 Contents PREMISE. Perimeter intrusion detection system...5 CHAPTER 1. system...7 1.1 The components of the system... 8 1.1
More informationresistance for high requirement
HEVY DUTY FLOOR OXES >>> NEW High resistance for high requirement For highly frequented areas, requiring important mechanical resistance and/or washing down. heavy duty in-screed floor box s 896 83 896
More informationCoded magnetic safety sensor SR B series
Coded magnetic safety sensor SR B series Selection diagram CONTACTS 0 NC NC+NO NC+NO Contacts imply closed protection ACTUATOR SENSOR OUTPUT TYPE SM B0F actuation distance mm SM B0F actuation distance
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationScreened highly flexible data transmission cable with PUR outer sheath and twisted pairs - UL/CSA-listed
Screened highly flexible data transmission cable with PUR outer sheath and twisted pairs - UL/CSA-listed : Low-frequency PUR data cable UL AWM CMX VW-1 Halogen-free, Highly flexible Drag chain, Screened
More informationVM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H
VM series Cylindrical M2 in AC inductive sensors warranty features warranty Output: cable and M2 plug cable exit Models with 2 wires IP67 protection degree Multivoltage 20...253 Vac web contents Application
More informationSafety coded magnetic sensor SR A series
Safety coded magnetic sensor SR A series Selection diagram CONTACTS 0 +NO NC+NO Contacts imply closed protection ACTUATOR SENSOR SM A0N actuation distance 5 mm OUTPUT TYPE SR AD N integrated PVC cable
More informationCombined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide
Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with
More informationSynchro-check relay. Application
Issued: April 1999 Status: Updated Version: B/08.11.2001 Data subject to change without notice Features Two identical operation stages allowing the closing conditions of two separate circuit breakers to
More informationPLPC905GL-3-KNX / PLPC905GL-3-HD-KNX / PLPC905GL-4-KNX / PLPC905GL-4-HD-KNX LightMaster Dimmer Actuator
Features Supply 100-240V 50/60Hz single phase at 16A. Switched Outputs 9 x Maintained NC switched output 9 x Switched outputs, total box load 16A Standard & Heavy Duty (HD) models Mains switched outputs,
More informationBS 6346/EEMUA Pub.N 133 Armoured (LC-SWA) Flame retardant
CABLE JOINTS, CABLE TERMINATIONS, CABLE GLANDS, CABLE CLEATS FEEDER PILLARS, FUSE LINKS, ARC FLASH, CABLE ROLLERS, CUT-OUTS Contact 11KV 33KV CABLE JOINTS & CABLE TERMINATIONS FURSE EARTHING Cables for
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More information3 analog linear/rotary transducers and 3 digital transducers inputs for travel/ speed analysis
The ultimate all-in-one circuit breaker analyzer: safer, faster and more accurate than ever. It allows any timing test, motion and speed analysis, multiple contemporary static and dynamic contact resistance
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationUsed for outdoor and indoor installations in damp and wet locations for supplying power to electrical units and equipments
Multi Core Cables Used for outdoor and indoor installations in damp and wet locations for supplying power to electrical units and equipments www.alfanar.com Solid Cables PVC Insulated and PVC Sheathed,
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationEthernet cabling. B Ethernet cabling. Ethernet cabling overview B 2. Cabling 4-poles IP 20 B.1 8 IP 65 / IP 67 B Cables B Tools B.
Ethernet cabling Contents Page B Ethernet cabling Ethernet cabling overview B 2 Cabling 4-poles B.1 8 B.1 22 Cables B.1 96 Tools B.1 104 Cabling 8-poles B.2 8 B.2 20 Cables B.2 90 Tools B.2 98 B 1 Profile
More informationConnect Electricians' tools, consumables and enclosures
Connect Electricians' tools, consumables and enclosures 220 Tooling and consumables including electricians' hand tools, electrical insulation tapes, cable pulling socks, morse hole saws & accessories
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationOperating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...
Safety sensor BNS 0 Disassembly and disposal. Disassembly..... Disposal... 7 EU Declaration of conformity Operating instructions.............pages to Original x.000 / 09.08 / v.a. - 08- / Q / 08-09- /
More informationLighting control for commercial buildings
[ INTELLIGENT SOLUTIONS ] Products and systems Lighting control for commercial buildings For management of different functions in a simultaneous and integrated way, via a BUS line Cost saving thanks to
More informationRXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13
s 3 875 RXB Room controller Communicating room controller for fan-coil applications FC-13 RXB39.1 The RXB39.1 room controller is used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationSafety. Detection. Control. MAGNUS RFID ENG - REV
03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide
More informationConnecting a Cisco Output Module
CHAPTER 5 Overview The optional Cisco Output Module (Figure 5-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to 8 outputs, each of which
More information1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output
More informationSPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING USB 2.0 / 3.0 CABLES. Kuka
SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING USB 2.0 / 3.0 CABLES Kuka CONTENT OVERVIEW Who we are................................................................................................................
More informationDGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field
DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description
More informationInstaller manual. Eikon Arké Plana BUS EnOcean interface - 2 modules
Installer manual Eikon 20508 Arké 19508 Plana 14508 BUS EnOcean interface - 2 modules Instructions This manual is necessary in order to configure the radio-frequency devices when used with the By-me automation
More informationInstaller manual. Eikon Arké Plana BUS EnOcean interface - 2 modules
Installer manual Eikon 20508 Arké 19508 Plana 14508 BUS EnOcean interface - 2 modules Instructions This manual is necessary in order to configure the radio-frequency devices when used with the By-me automation
More informationInsulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting
Insulated Enclosure KU 4090 to DIN 43 880 for installation in distribution cabinets or surface mounting Width 105 mm Uo to 48 plus-minus-terminal screws with self raising terminal washers. Part insertion
More informationRoom Temperature Controller
3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:
More informationCombined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide
Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationH Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION
H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the
More informationEarth-fault Relay SPAJ 110 C. Product Guide
Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral
More informationLevel Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75
Level Transmitter Construction The GEMÜ level transmitter has an immersion tube with reed contacts and a chain of resistors which are triggered by a float with an integrated permanent magnet. A threaded
More informationPU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance
PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without
More informationFeeder protection relay SPAA 341 C. Product Guide
Issued: April 1999 Status: Updated Version: D/07.03.2006 Data subject to change without notice Features Comprehensive numerical feeder protection relay consisting of two multi-function protection relay
More informationMMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A
AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,
More information5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line
Product Overview 5 / 8 Port Gigabit Ethernet Industrial Switches Entry Line Description The new Gigabit Ethernet industrial switch offers the full Gigabit performance on all ports. This offers, beside
More informationSignum Complete Scale Advanced SIWABBP SIWADCP SIWAEDG
Signum Complete Scale Advanced SIWABBP SIWADCP SIWAEDG Mechatronic weighing system SIWABBP: Resolutions of up to 150,000 d Signum Complete Scales SIWADCP EDG: Resolutions of up to 80,000 d Includes multiple
More informationMultifunction Transducer MT440
Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up
More informationSALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT
SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationOperating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...
6 Disassembly and disposal 6.1 Disassembly....6 6.2 Disposal...6 7 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 09.2017 / v.a. - 101178533- / I / 2017-08-31
More informationInstallation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster
Installation / control / monitoring technique CANopen PLC IL, IN minimaster 6 Circuit diagram CAN H Rab C CAN L C IL IN C CAN H Rab CAN L C According to IEC/EN 6 -, EN 78 Operation as master - Operation
More informationConnect. Electricians' tools, consumables and enclosures x 210.0mm x 210.0mm. 26.0mm. 6.0mm. 6.0mm. 6.0mm. 12.0mm.
Connect Electricians' tools, consumables and enclosures Tooling and consumables which includes hand tools, crimping tools and solar tools for MC3 & MC4 connectors, electrical insulation tapes, cable pulling
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More informationThermal-Magnetic Circuit Breaker 4220-T...
Thermal-Magnetic Circuit Breaker 40-T... Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 (5 ka), EN/IEC 60934 (6kA) and UL 077 (5 ka). With
More informationSmartLogger1000 Quick Guide. Issue: 10 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SmartLogger1000 Quick Guide Issue: 10 Part Number: 31505707 Date: 2017-06-13 HUAWEI TECHNOLOGIES CO., LTD. 1. The information in this document is subject to change without notice. Every effort has been
More informationRТTH DUAL ROOM SWITCH
DUAL ROOM SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA
More informationPSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU. Requirements of. Grade 1 Grade 2 Grade 3
KOD: TYP: PSBEN 2012B/LCD v.1.0 PSBEN 13,8V/2A/7Ah/EN/LCD buffer, switched mode PSU EN BLACK POWER This product is suitable for the systems designed in compliance with the PN-EN 50131-6 grade 1, 2 or 3
More informationSWISS MADE. Series 320 XT PREMIUM. Analytical. Precision
SWISS MADE PREMIUM Series Analytical Precision PREMIUM Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated
More informationInstallation / Control / Monitoring Technique
Installation / Control / Monitoring Technique MINIMASTER CANopen PLC IL, IN 6 Your Advantages Compact CAN-operation Graphical programming Qquick and easy installation Various input- / output module digital
More informationInReg Volume flow controller Pa
InReg Volume flow controller 0...300 Pa Electrical volume flow controller (CAV / VAV) for use in safe areas 24 VAC / DC supply, adaptive PID controller, alarm contact InReg - V... InReg - V... - A InReg
More informationInBin-P Pressure switches from 5 Pa Pa
InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationDevices raised mounting
Devices raised mounting Illuminated actuator pushbutton Front protection Switching system Ø 29 mm Contacts Typ-Nr. e Illuminated actuator pushbutton IP 67 LL 1 NC - MA UT 14-476.36 1 4 17 12.15 M UT 14-436.36
More informationKey Switch. Document version: 1.5 (Updated 02 May 2017)
Key Switch Document version: 1.5 (Updated 02 May 2017) Contents ii Contents 1 Key Switch R10S.3... 4 2 Quick Guides...4 2.1 Controlling an Electric Lock...5 2.2 Controlling an Alarm System... 5 2.3 Controlling
More informationMPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationInstallation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster
Installation / control / monitoring technique CANopen PLC IL, IN minimaster 6 Circuit diagram CAN H Rab CAN H CAN CAN L GND C C CAN L C C Rab M88_a IL IN CAN H CAN H Rab CAN CAN L GND C C Rab CAN L C C
More informationVoltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice
Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationNEW 74 PS RANGE. Push-buttons, selectors and indicators ø 22mm
NEW 74 PS RANGE Push-buttons, selectors and indicators ø 22mm 74 PS RANGE Push-buttons, selectors and indicators ø 22mm The 74 PS range: a system of push-buttons, selectors and indicators with a 22mm diameter
More information_ Access control SISTEMAS DE SEGURIDAD
_ Access control SISTEMAS DE SEGURIDAD SECURITY SYSTEMS Access control 01 Concept 02 Product 03 Characteristics 04 Compatibility 05 New functions 06 New software 07 References, accessories and diagrams
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationSee instructions to download and install the latest version of LinkBoxLON and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationOccupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE
Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE 2 Part Number: WIR-3110 WARNING! SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES
More informationFeeder protection relay
Page 1 Issued: April 1999 Status: New Data subject to change without notice Features Comprehensive numerical feeder protection relay consisting of two multi-function protection relay modules and a flexible
More informationCALEC energy master The benchmark in energy measurement
CALEC energy master The benchmark in energy measurement District heating and cooling: New tariff structures for optimum plant management Secure investment with long-term stability Type approval to EU/2004/22
More informationPriva Blue ID C-Line system overview
Priva Blue ID C-Line system overview Simple wiring Peripheral hardware wiring can be connected very easily. Wiring can be inserted into the default terminal block or screwed into the optional screw connectors.
More informationDORMA. Access Control
DORMA Access Control CODIC MasterCard Access Control CODIC MasterCard the proximity access control system The innovative CODIC MasterCard access control system from DORMA operates on the basis of proximity
More informationCABINETS & ENCLOSURES FOR PREPAYMENT METERS
CABINETS & ENCLOSURES FOR PREPAYMENT METERS Solutions designed according to customer need, conceived for every type of prepayment meter: > Meters with keypad data entry terminal > Split meters with remote
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationBT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013
Technical Specification Sheet Document No. 149-711 March 4, 2013 BT300 HVAC Drives Designed for HVAC Figure 1. BT300 HVAC Drive without and with Integral Disconnect. Description Siemens Industry's BT300
More informationInductive sensor with analog output BI15-M30-LI-EXI
ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection
More informationDiagnostics (Logical) Diagnostics (Physical)
Enclosure Mounted Input/Output Stations In-Cabinet I/O IP 20 Protection Ideal for Retrofits Automatic Baud Rate Sensing FDN20-4S-4XSG FDN20-4S-4XSG-E* FDN20-4S-4XSG-DIN* * Not UL Electrical Operating Current:
More informationInductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More information1/5 SING.-FMLY KIT W/VANDALCOM & PC INTERCOM VIP SYST. KIT H.264 OVERVIEW 8504H
1/5 OVERVIEW The kit consists of 1 colour audio/video unit art. 4682HKC, 1 module with 1 button art. 3268I/1, 1 flush-mounted box art. 3160/1, 1 frame complete with finishing frame art. 3161/1, 1 power
More informationMID approval no. DE-08-MI004-PTB004 Date of release
1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application
More informationSWA Cable BS5467 Steel Wire Armoured PVC
SWA Cable BS5467 Steel Wire Armoured PVC Application SWA cable power and auxiliary control cables for use in power networks, underground, outdoor and indoor applications and for use in cable ducting Standards
More informationPOE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from
POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible
More informationSafety coded magnetic sensor SR B series
Safety coded magnetic sensor SR B series Selection diagram 0 NC NC+NO NC+NO Contacts have to be intended with closed protection. CONTACTS ACTUATOR SENSOR SM B0F actuation distance mm SM B0F actuation distance
More information