LabEXCEL Clino. Manual. WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland. Tel (0) Fax (0)

Size: px
Start display at page:

Download "LabEXCEL Clino. Manual. WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland. Tel (0) Fax (0)"

Transcription

1 WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel (0) Fax (0) Homepage: Manual LabEXCEL Clino "LabEXCEL Clino" software display during measurement File: LabEXCEL Clino_en.doc

2 page 2 of 24

3 INDEX 1. INTRODUCTION GENERAL LABVIEW BY NATIONAL INSTRUMENTS SOFTWARE LICENCE AGREEMENT SOFTWARE INSTALLATION 6 2. CONFIGURATION OF THE SOFTWARE "LABEXCEL CLINO" STARTING THE PROGRAM "LABEXCEL CLINO" OVERVIEW OF THE MOST IMPORTANT FUNCTIONS SEARCHING THE SERIAL PORTS SETUP OF MEASUREMENT TASK / MEASUREMENT PARAMETERS SET-UP OF PROTOCOL STARTING A MEASUREMENT TERMINATION OF THE MEASUREMENT AND CLOSING THE SOFTWARE ANALYZING THE RESULTS REPEATING A MEASUREMENT / RESTART REPEATING A MEASUREMENT RESTART OF THE PROGRAM "ZERO-SETTING" / ABSOLUTE ZERO PROCEDURE TO DETERMINE THE ZERO-OFFSET: SUPPORT TECHNICAL SUPPORT 23 Modifications: Date Modified by Description of modifications MG Excel separated, Buffer Restart added MG Minor changes in the section close page 3 of 24

4 1. INTRODUCTION 1.1 GENERAL "LabEXCEL Clino" is a simple to use software to display values measured with the WYLER inclination measuring instruments CLINOTRONIC PLUS. The software is based on the LabVIEW platform by National Instruments. The heart is the WYLER software module WyBus developed for the communication between the instruments and the software LabVIEW. The measuring results can be transferred continuously to a.csv file for further treatment in EXCEL. Precondition for the software installation of LabEXCEL Clino is: Windows XP or higher Microsoft EXCEL, minimum version 2003.NET Framework 2.0 (Microsoft.NET Framework 2.0) Download via {Windows-Update} or from the enclosed CD_ROM / Directory { Microsoft.NET Framework 2.0 Installer}/dotnetfx.exe 20 MB free space on hard disk Up to 2 inclination measuring instruments CLINOTRONIC PLUS can be monitored simultaneously with LabEXCEL Clino. In addition it is possible to measure the difference between any two different inclination measuring instruments CLINOTRONIC PLUS. 1.2 LABVIEW BY NATIONAL INSTRUMENTS Testing and measurements technology by National Instruments. National Instruments is one of the world s leaders in virtual instrumentation - a revolutionary concept based on computer and computer related technology. In connection with specifically developed userfriendly hard- and software for test and measuring applications the National Instruments concept allows the user to increase the productivity and lower the respective costs. page 4 of 24

5 1.3 SOFTWARE LICENCE AGREEMENT PRODUCT LICENCE AGREEMENT WYLER AG CH-8405 WINTERTHUR / SWITZERLAND The following is our standard licence agreement. The licence issued with each product will have the product name (e.g. LabEXCEL, LabEXCEL WyBus or DYNAM) substituted for the words "the program" where they appear below. 1. WYLER AG licences you to use the program (including the installation program) provided that you comply with the following: a. You (or your duly authorised employees) will be the only person to use the program. Employees authorised by you are permitted to use the program for your purposes only. b. You only copy the program onto the hard disk of your computer. That where the software is installed on any multi-user or networked computer system, you will purchase a separate licence for each computer that will access to the program. c. That at any one time the program (or any part of it) does not exist in the memory (ROM or RAM, or any other type of memory) of more than one computer. d. That you do not alter, modify, reverse engineer, reverse assemble or reverse compile the program or the Install program. e. That you do not assign, sell or otherwise transfer the program to another person or allow another person to use it. f. That you use the program in accordance with the instructions provided 2. Subject to the existing laws, by the giving of the licence WYLER AG IS NOT: a. Giving you any title to or ownership in the program b. Accepting any responsibility for any damage caused by, or as a consequence of the operation of the program. 3. WYLER AG makes the program available in good faith and believes that it functions as described in the documentation. While we intend to continue developing the program, and would like to know of any problems that you experience with it, we are not undertaking in this licence to fix those problems. We reserve the right, in our absolute discretion, to fix any problems. 4. Should the distribution media supplied prove to be faulty then we will replace it provided it is returned within thirty days of us sending it to you. 5. This licence is and will be governed and interpreted according to the law of SWITZERLAND. IT IS A BREACH OF THE COPYRIGHT ACT TO COPY THE PROGRAM WITHOUT OUR PERMISSION. THE ACT PROVIDES FOR A FINE TO BE IMPOSED ON ANY PERSON WHO COPIES THE SOFTWARE WITHOUT PERMISSION. WE WOULD ALSO BE ENTITLED TO SEEK DAMAGES IN THOSE CIRCUMSTANCES. IF PEOPLE MAKE USE OF THE PROGRAM WITHOUT PAYING THE LICENCE FEE THEN WE WILL BE DEPRIVED OF INCOME AND THE PROGRAM MAY NOT BE DEVELOPED FURTHER. LEVELSOFT and DYNAM are trademarks of WYLER AG, CH-8405 WINTERTHUR / SWITZERLAND page 5 of 24

6 1.4 SOFTWARE INSTALLATION The file "Setup.exe" is located in the "Volume" of the CD "LabEXCEL Clino". With double click to this file the software "LabEXCEL Clino" will be installed on the computer. Just follow the instruction displayed on the monitor. When the installation is finished the following icon will be seen on the desktop. After connecting the instruments to the PC the software "LabEXCEL Clino" can be started. The possible configuration is described in the following chapters. Icon LabEXCEL Clino page 6 of 24

7 2. CONFIGURATION OF THE SOFTWARE "LABEXCEL CLINO" 2.1 STARTING THE PROGRAM "LABEXCEL CLINO" After connecting the instruments to the PC the software "LabEXCEL Clino" can be started by a doubleclick to the icon on the desktop or via "Programs / WYLER LabEXCEL Clino / LabEXCEL Clino". The instruments may be connected to the PC through a RS232 port or a USB port. Please be aware that most of the WYLER instruments and sensors use the RS485 protocol and therefore need a converter adapter. If clarification is required please do not hesitate to contact WYLER or the local representative. 2.2 OVERVIEW OF THE MOST IMPORTANT FUNCTIONS LabEXCEL Clino Monitor Instruments Evaluation with Excel using numerical measuring values graphical display (must be done manually) After starting the measurement the measured values will be displayed continuously on the monitor of LabEXCEL WyBus in graphical and numerical form. Depending on the users requirements the values may be transferred to a.csv file continuously or periodically and evaluated later on in Excel. page 7 of 24

8 2.3 SEARCHING THE SERIAL PORTS After starting the program the window "System configuration" is displayed and all the available ports on the PC are listed. With the first start of the program the list of available COM-ports must be up-dated using the [List COM Ports] button. Indicators Select now the COM-Port(s) to which the measuring instrument(s) are connected. It is possible to activate all available COM-Ports. In this case the search for measuring instruments and sensors will take correspondingly more time. After clicking on the button [List Devices] the selected COM Ports will be searched for measuring instruments connected (takes approx. 10 seconds for each COM-Port). While searching the COM-Ports the blue indicator below "COM Ports Connected" is flashing. Up to 2 measuring instruments CLINOTRONIC PLUS can be connected. page 8 of 24

9 The measuring instruments connected to the activated ports will be listed as "Available Devices". Pull now the measuring instrument(s) you intend to use for the next measurement to the respective square under "Select and connect devices" using Drag & Drop. Before the instruments are connected [Connect Devices] and the measurement is started the setup and the protocol header must be configured. Information regarding the index part of the serial number Instruments / Sensors Clinotronic PLUS H4001C page 9 of 24

10 2.4 SETUP OF MEASUREMENT TASK / MEASUREMENT PARAMETERS Change to the menu "Measure Settings". Status Indicators On the top edge of the program window the following functions are displayed (indicators) WyBus running shining blue COM Ports Connected shining blue Devices Connected still inactive Sampling still inactive The active functions are shining blue. Under "Measurement Parameter" the following settings can be made: Measurement parameters (Measuring mode) SINGLE: Individual measurement CONTINUOUS: Continuous measurement; measuring time (signal interval) depending on the setting under "Integral Time INTERVAL: Measurements in intervals; measuring time (integral time) and interval (interval time) TIME TRIGGERED: Measurement from until, measuring time (integral time) and interval (interval time). The start/stop procedure may be selected through a calendar function Units (measuring units) mrad µrad Deg Arcsec mm/m Attention: The measuring units can only be changed while the measuring instruments are logically separated (disconnected). page 10 of 24

11 Select Timing Settings Integral Time in [s]: During the entered time span the measuring values will be integrated Device Sampling Time in [s]: Sampling time, if the sampling time entered is shorter than the sampling time of the device connected, intermediate values will be interpolated. Interval Time: Measuring interval. Only active in the modes "Interval" and "Time triggered" Tolerance in [%]: Indication of the number of values, which may be missing within the integral time for the calculation of the average value Start Time: Entry of the start time for a long term measurement. Only active in the mode "Time triggered" Stop Time: Entry of the end time for a long term measurement. Only active in the mode "Time triggered" 2.5 SET-UP OF PROTOCOL Change now to the tab "CSV Protocol-Head. Entering the measurement data for the protocol: Path of CSV-File: List Separator Name of Operator: Name of Measured Object: Serial Number of Measurement Device Add Comment: System Time: Autosave Parameter: Buffer Restart The directory where the protocols shall be saved can freely be selected. A valid path is required in order to save data! Separator for the.csv file. Must correspond with the regional settings in order to display the measuring values correctly when reading them into Excel Name of the user / operator Name of the measured object Serial Number(s) of the measuring instrument(s) additional information Display of the actual system time When this function is activated the.csv file will be up-dated and saved according to the pre-set intervals When this function is activated a new.csv file will be created according to the pre-set intervals It is recommended to use a new file name for every new measurement (path of CSV file). page 11 of 24

12 As a next step change to the tab "System Configuration". Activate now the connection of the required respectively activated measuring instruments and sensors by clicking to the button [Connect Devices]. Attention: As soon as this function is activated no changes to the measuring parameters can be applied any more. 2.6 STARTING A MEASUREMENT Select again the tab [System Configuration]. There you will find the following display. All the steps up to the listing and selection of the instruments to be measured have been made earlier (Chapter 2.3 Searching the serial ports ). Push now the [Connect Devices] button. Thus the instruments selected will be connected to the software. The displayed information will fade and can no longer be changed. page 12 of 24

13 Select now the program tab "Measurement". In this program window you have now the option to display additionally the difference between two measuring instruments. The calculation pattern can be selected under "Select Subtraction". In the fields "Select Visible Plots" you activate the display of the plots you would like to have shown on the monitor. Activation of Plots Differential Measurement The measurement can now be started using the [Start] button and stopped using the [Stop] button. In case you have not activated the "Autosave" function (automatic up-dating of CSV-file) the report can be started respectively up-dated manually using the [Create] button. As soon as the parameters between the measurements have been changed and a CSV-report has been created or up-dated you will be asked to enter a new file name. You can overwrite an existing file. page 13 of 24

14 In case individual measurement values are "lost a marker is set below "Values missing at plot. The details can be viewed in the.csv file. Actual measuring value of the measuring instruments / sensors connected Continuous graphical display of the values measured Actual measured differential value Sensor [A] Sensor [B] Setting ot the differntial values of sensors The measurement can be started using the key [Start] or be stopped using [Stop] page 14 of 24

15 2.7 TERMINATION OF THE MEASUREMENT AND CLOSING THE SOFTWARE First use the button [Stop] for terminating the running measurement. Click on the button [Create] in order to save the measuring values. Change afterwards to the tab "System Configuration" and interrupt the link to the measuring instruments using the button [Disconnect Devices] and then terminate the measuring program using the button [Quit]. When closing the program using the button in the upper right corner of the window, the program closes without saving the data. When closing the program using [Quit] the following dialog box will appear With [Save] the last measuring values will be saved in the.csv file. When "Autosave" is active this will be done automatically. page 15 of 24

16 2.8 ANALYZING THE RESULTS IN EXCEL With a double click on the.csv file the data will automatically be loaded into Microsoft EXCEL. Note: If no value has been entered into the EXCEL-sheet, this means that the corresponding sensor or instrument was in over range at that time page 16 of 24

17 3. REPEATING A MEASUREMENT / RESTART 3.1 REPEATING A MEASUREMENT After terminating a measurement and during the shut down of the system the last measurement configuration will be saved. When starting the program "LabEXCEL Clino" again the last configuration will be started. The following window appears. During the start-up of the program the blue light below "COM Ports Connected" is blinking. Provided that the same instruments are connected to the same ports, the measurement setup is started automatically. page 17 of 24

18 The measurement can be started by using the key [Start]. If since the last measurement the configuration or other instruments are connected the submenu "System Configuration" is displayed after a few seconds. Using [Connect COM Ports] and [List Devices] the new instruments/sensors may be listed. For further procedure please see chapter 2.1 Starting the program "LabEXCEL Clino" page 18 of 24

19 3.2 RESTART OF THE PROGRAM The current measuring configuration is saved automatically after each change. When the system starts up again, the last memorised measuring configuration will automatically be restarted. The measurement can be started by using the key [Start]. page 19 of 24

20 4. "ZERO-SETTING" / ABSOLUTE ZERO Absolute ZERO means that the measuring instruments and/or sensors show the measuring value "0" when the measuring face of the instrument/sensor is aligned exactly according to gravity. The absolute zero will be determined from a reversal measurement and used as the basis for absolute inclinations measurements. To assure the best possible precision make sure that the measuring object (support) and the measuring instruments connected have the same temperature and that the instruments are switched on for a few minutes. Mark the precise spot and particularly the direction of the measuring instruments and/or sensors connected in order to be able to turn them by 180 degrees and to set them precisely to the same spot in the opposite direction. Example using a BlueLEVEL: Reversal measurement for determining I. Zero point deviation of the instrument N m II. Inclination of the measured surface N p Zero point deviation of the instrument N m : Inclination of the measured surface N p : The value of the "Zero-offset" determined by a reversal measurement corresponds to the deviation of the Zero point of the measuring instrument compared to the absolute Zero (gravity). The displayed value is subsequently calculated as follows: VALUE displayed = Value of the measuring instrument minus "Zero offset" The reversal measurement described above should be repeated periodically in order to achieve a high measuring precision, particularly when the instruments have not been in use for a longer period. page 20 of 24

21 4.1 PROCEDURE TO DETERMINE THE ZERO-OFFSET: After having initialised the measurement as described in chapter 2.6 "Starting a measurement", the tab [Zero offset] will get active. Select the instruments, for which you want to set the Zero offset, from the list of instruments. You select by activating the tick behind the serial number of the sensor. Click on the button [Start], in order to start measuring the first values. The measured values will be displayed in the column "Zero Values List". As soon as the fonts on the button [Set Values (List A)] change from red to green, the values for measurement A, respectively X, can be memorised by a click on the button [Set Values (List A)]. page 21 of 24

22 Turn now the instruments by 180 and putt hem on the very same spot in opposite direction. As soon as the fonts on the button [Set Values (List B)] change from red to green, the values for measurement B, respectively X', can be memorised by a click on the button [Set Values (List B)]. As soon as both values A and B, respectively X and X' are available, the new Zero offset will be calculated. With a click on the button [Write Back] the new Zero offset value will be stored into the instruments. As soon as this is completed the measurement will be stopped and the list will be cleared. Advice: If you do not turn the instruments by 180 you can also use the Zero offset as a "relative Zero", this means that the instruments will afterwards show an inclination of 0 for the present position. page 22 of 24

23 5. SUPPORT 5.1 TECHNICAL SUPPORT In case of any problems with the installation or the operation of the software "LabEXCEL WyBus", please contact your local WYLER distribution partner or WYLER SWITZERLAND directly. page 23 of 24

24 WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel (0) Fax (0) Homepage: page 24 of 24

LabEXCEL WyBus. Manual. WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland. Tel (0) Fax (0)

LabEXCEL WyBus. Manual. WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland. Tel (0) Fax (0) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Manual LabEXCEL WyBus "LabEXCEL WyBus

More information

Instruction Upgrade of firmware

Instruction Upgrade of firmware WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Instruction Upgrade of firmware Mai

More information

DATA LOGGER (Version V1.3)

DATA LOGGER (Version V1.3) WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com Operating instructions DATA LOGGER (Version

More information

JANOME ELECTRO PRESS. Operation Manual. <PC Operation>

JANOME ELECTRO PRESS. Operation Manual. <PC Operation> JANOME ELECTRO PRESS JP-104 JP-204 JP-504 JP-1004 JP-1504 JP-3004 JP-5004 JPH-104 JPH-204 JPH-504 JPH-1004 JPH-1504 JPH-3004 JPH-5004 JPU-104 JPU-204 JPU-504 JPU-1004 JPU-1504 JPU-3004 JPU-5004 JPU-8004

More information

Smart Monitor ZG2 User s Manual

Smart Monitor ZG2 User s Manual Smart Monitor ZG2 User s Manual Smart Sensors ZG2 Series 2D Profile Measuring Sensors CONTENTS SMART MONITOR ZG2 USER S MANUAL...1 SECTION 1 PREPARATIONS...2 Installing the Smart Monitor ZG2 on a Computer...

More information

SoftTools Suite 7.0. Flowserve Corporation

SoftTools Suite 7.0. Flowserve Corporation SoftTools Suite 7.0 Quick Start Guide for SoftTools 7.0 with support for the HART Communications Protocol on the Logix 1200/1200e, 3200IQ, and 500/500si Series Positioners Flowserve Corporation Flow Control

More information

RunningBall Trader Client

RunningBall Trader Client RunningBall Trader Client Date: > 22/12/2016 Revision: > 1.6.0 Disclaimer Copyright 2016 RunningBall AG. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored

More information

Quick Start Guide Date: > 05/11/2015 Revision: > 1.0.0

Quick Start Guide Date: > 05/11/2015 Revision: > 1.0.0 RunningBall Trader Client Quick Start Guide Date: > 05/11/2015 Revision: > 1.0.0 Disclaimer Copyright 2015 RunningBall AG. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

UNIVERSAL SOFTWARE. Universal Software. Data Sheet Universal Software Data Sheet System Requirements: The minimum requirements for using the Software are: 1). Windows XP/Vista/7 2). A minimum of 512 MB RAM 3). 1 GB of hard disk space 4). Microsoft Office

More information

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies

RWD32S Software Tool. Operating Instructions. CE1U3344en Building Technologies RWD32S Software Tool Operating Instructions CE1U3344en 25.06.2009 Building Technologies Siemens Switzerland Ltd Industry Sector Building Technologies Division International Headquarters HVAC Products Gubelstrasse

More information

N2KExtractor. NMEA 2000 Data Extractor Software. User s Manual

N2KExtractor. NMEA 2000 Data Extractor Software. User s Manual N2KExtractor NMEA 2000 Data Extractor Software User s Manual Revision 1.0.0 Copyright 2012 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

GV 2 Devicemanagement 2

GV 2 Devicemanagement 2 GV 2 Devicemanagement 2 getting started & usage 1/13 Index 1 General Remarks...3 2 Software...3 2.1 System Requirements...3 2.2 Installation...4 2.3 Un-Installation...5 3 User Interface...5 3.1 Menu Bar...6

More information

INSTRUCTION MANUAL. IBREXDLL Software for MS Excel. M e t r o l o g y. Messtechnik GmbH & Co. KG

INSTRUCTION MANUAL. IBREXDLL Software for MS Excel. M e t r o l o g y. Messtechnik GmbH & Co. KG M e t r o l o g y INSTRUCTION MANUAL Software for MS Excel Document No. : D2MF710 001 Edition : April 2009 Copyright : IBR Messtechnik GmbH & Co. KG Contents 1. Introduction... : 3 2. Features... : 3 3.

More information

7. copy or distribute the Software, or any part thereof, or any accompanying documentation or part thereof, other than in accordance with 3.

7. copy or distribute the Software, or any part thereof, or any accompanying documentation or part thereof, other than in accordance with 3. 1 Before You Begin AUSTRALIAN ACCESS SOFTWARE LICENCE AGREEMENT IMPORTANT - READ CAREFULLY 30 DAYS EVALUATION AND FULL LICENSED VERSIONS: A. By agreeing to this licence agreement and/or by installing,

More information

Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices

Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices Notes on installing and using the OM-USB-5201 and OM-USB-5203 data logging devices Thank you for purchasing the OM-USB-5201 or OM-USB-5203 device from Omega Engineering! Please read this sheet to help

More information

M-bus configuration and readout software ACT531 User s guide

M-bus configuration and readout software ACT531 User s guide s M-bus configuration and readout software ACT531 User s guide 012_A6V10844345_en_c 2018-09-13 Building Technologies Published by: Siemens Switzerland Ltd. Building Technologies Division International

More information

Roland Software Package (RSP-009) SOFTWARE GUIDE

Roland Software Package (RSP-009) SOFTWARE GUIDE Roland Software Package (RSP-009) SOFTWARE GUIDE Thank you very much for purchasing this product. To ensure correct and safe usage with a full understanding of this product's performance, please be sure

More information

testo Comfort Software CFR 4 Instruction manual

testo Comfort Software CFR 4 Instruction manual testo Comfort Software CFR 4 Instruction manual 2 1 Contents 1 Contents 1 Contents... 3 2 Specifications... 4 2.1. Intended purpose... 4 2.2. 21 CFR Part 11 and terminology used... 5 3 First steps... 9

More information

eturboware 4.x For Windows 2000/XP User s Guide Part No: M , Ver:1.0

eturboware 4.x For Windows 2000/XP User s Guide Part No: M , Ver:1.0 eturboware 4.x For Windows 2000/XP User s Guide Part No: M3-000016, Ver:1.0 The information in this document is subject to change without notice. No part of this document may be reproduced or transmitted

More information

Thank you for choosing Loadstar Sensors. Need additional help? Call us at or us at

Thank you for choosing Loadstar Sensors. Need additional help? Call us at or  us at LoadVUE User Guide LoadVUE LoadVUE Lite Thank you for choosing Loadstar Sensors. Need additional help? Call us at 510-623-9600 or email us at support@loadstarsensors.com LoadVUE is compatible with Windows

More information

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13

-Table of Contents- 1. Overview Installation and removal Operation Main menu Trend graph... 13 Thank you for buying Data Analysis Software. In order to use this software correctly and safely and to prevent trouble, please read this manual carefully. Notice 1. No part of this manual can be reproduced

More information

Quantum Blue Reader QB Soft

Quantum Blue Reader QB Soft Quantum Blue Reader QB Soft User Manual V02; 08/2013 BÜHLMANN LABORATORIES AG Baselstrasse 55 CH - 4124 Schönenbuch, Switzerland Tel.: +41 61 487 1212 Fax: +41 61 487 1234 info@buhlmannlabs.ch Contents

More information

Data setting software MEXE02

Data setting software MEXE02 HM-40143 Data setting software MEXE02 OPERATING MANUAL Before Use Thank you for purchasing an Oriental Motor product. This operating manual describes product handling procedures and safety precautions.

More information

PocketWeave User s Manual

PocketWeave User s Manual PocketWeave User s Manual Version 1.1 Written by Kriston M. Bruland AVL Looms 3851 Morrow Lane, Suite #9 Chico, CA 95928-8305 U.S.A. 530 893-4915 530 893-1372 (fax #) info@avlusa.com (e-mail) www.avlusa.com

More information

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel v3.1.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER...2 1.1 CONTROLLER...2 1.2 SPECIFICATIONS AND FEATURES...3 CHAPTER

More information

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4

TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel User manual for WindowsNT4 Version: 3.1.4 TouchKit Touch Panel v3.1.4 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES... 3 CHAPTER

More information

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0

TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0 TouchKit TouchScreen Controller User Manual for Windows NT4 Version: 3.4.0 1 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER 2 1.1 Controller 2 1.2 Specifications and Features 3 CHAPTER 2. INSTALLING TOUCHKIT

More information

OPERATOR S MANUAL. The intelligent universal inclinometer

OPERATOR S MANUAL. The intelligent universal inclinometer WYLER AG Im Hölderli CH-8405 WINTERTHUR Switzerland Tel. 0041 (0) 52 233 66 66 Fax. 0041 (0) 52 233 20 53 Homepage: http://www.wylerag.com E-Mail: wyler@wylerag.com OPERATOR S MANUAL The intelligent universal

More information

InkZone2Optim. Page 1/11

InkZone2Optim. Page 1/11 InkZone2Optim Page 1/11 Content 1.1 System requirements 3 1.2 Software installation 3 1.3 Dongle installation 6 2.1 How it works 6 2.2 Overview 7 3.1 Start the software 7 3.2 Tab Convert Press 8 3.3 Tab

More information

Manual Software Firmware Loader V1.1

Manual Software Firmware Loader V1.1 Manual Software Firmware Loader V1.1 (PC software for Microsoft Windows XP, VISTA, 7, 10) This manual describes the installation of the Firmware Loader PC software and as a support for starting up the

More information

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1

TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1 TouchKit TouchScreen Controller User Guide for Windows NT4 Version: 3.2.1 TouchKit Guide for WinNT4 v3.2.1 0 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 2 1.1 CONTROLLER... 2 1.2 SPECIFICATIONS AND FEATURES...

More information

Instruction Manual XLComm Data Acquisition Software For XL Series Meters

Instruction Manual XLComm Data Acquisition Software For XL Series Meters Data Acquisition Software For XL Series Meters (XL 15, 20, 25, 30, 40, 50 and 60 meters) 68X090832 Rev. 0 JAN 07 Preface This manual serves to explain the use of the Acquisition Software. The manual functions

More information

Quick Start Guide Date: > Revision: > 1.1.3

Quick Start Guide Date: > Revision: > 1.1.3 RunningBall Trader Client Quick Start Guide Date: > 23.06.2014 Revision: > 1.1.3 Disclaimer Copyright 2014 RunningBall AG. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide This manual is the operation guide for Medal Editor. Please refer to this manual to install the software or create medal data used on the processing machine. Items That May

More information

DS2400 Series ToolBox Software Manual Ver 1.0

DS2400 Series ToolBox Software Manual Ver 1.0 DS2400 Series ToolBox Software Manual Ver 1.0 Tianjin Deviser Electronics Instrument Co., Ltd. Deviser Part No.: 2400 DL All rights reserved. Printed in CHINA. Apr. 2012. Index Chapter 1 Brief introduction...2

More information

MANUAL LSM UPDATE BASIC. Stand: May 2011

MANUAL LSM UPDATE BASIC. Stand: May 2011 Stand: May 2011 Table of Contents 1.0 Introduction... 4 1.1. Important note...4 2.0 Understanding this manual... 5 2.0 PRINCIPLES OF LSM... 6 2.1. System requirements: LSM 3.1 or higher (Subject to change)...6

More information

SONOFLOW Monitor Short Instructions. For SONOFLOW Sensors of the Series CO.55 V2.0

SONOFLOW Monitor Short Instructions. For SONOFLOW Sensors of the Series CO.55 V2.0 SONOFLOW Monitor Short Instructions For SONOFLOW Sensors of the Series CO.55 V2.0 Manufacturer: SONOTEC Ultraschallsensorik Halle GmbH Monitor model: SONOFLOW Monitor V02.xx For sensor types: Flow Sensors

More information

& Technical Specifications

& Technical Specifications User Manual & Technical Specifications User manual Contents Pidion BM-170 Technical specifications... 2 Micro Rolltalk basic package... 3 Micro Rolltalk functions and buttons... 3 Preparing Micro Rolltalk...

More information

One Click Technologies Limited. Customisation Cable & Software Manual. Part Number AVCP01

One Click Technologies Limited. Customisation Cable & Software Manual. Part Number AVCP01 One Click Technologies Limited Customisation Cable & Software Manual Part Number AVCP01 1 Installation One Click Customisation Cable & Software Manual IMPORTANT Use the AVCP01 customisation cable only

More information

GpsSimul User Guide 1. GpsSimul User Guide. User guide. (c) 2012 Sailsoft

GpsSimul User Guide 1. GpsSimul User Guide. User guide. (c) 2012 Sailsoft GpsSimul User Guide 1 GpsSimul User Guide User guide GpsSimul User Guide 2 Table of Contents GpsSimul User Guide... 3 Welcome to GpsSimul... 4 Licensing GpsSimul... 5 GpsSimul License... 5 Introduction...

More information

CX Recorder. User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0

CX Recorder. User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0 CX Recorder User Guide Version 1.0 February 8, 2010 Copyright 2010 SENSR LLC. All Rights Reserved. R001-418-V1.0 TABLE OF CONTENTS 1 PREAMBLE 3 1.1 Software License Agreement 3 2 INSTALLING CXRECORDER

More information

Instruction Manual. AP-SoftPrint. Multiwave 3000/ Multiwave ECO and Synthos 3000 Software v2.5

Instruction Manual. AP-SoftPrint. Multiwave 3000/ Multiwave ECO and Synthos 3000 Software v2.5 Instruction Manual AP-SoftPrint Multiwave 3000/ Multiwave ECO and Synthos 3000 Software v2.5 Instruction Manual AP-SoftPrint Multiwave 3000/ Multiwave ECO and Synthos 3000 Software v2.5 Anton Paar GmbH

More information

FlukeView. Users Manual. Software for ScopeMeter Test Tools

FlukeView. Users Manual. Software for ScopeMeter Test Tools FlukeView Software for ScopeMeter Test Tools Users Manual January 2016 2016 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. License Agreement 2006-2016

More information

LabVIEW Pump Control Program Using RS232 and USB

LabVIEW Pump Control Program Using RS232 and USB LabVIEW Pump Control Program Using RS232 and USB Syringe Pump Technical Bulletin TB39 Overview The current Teledyne ISCO D-Series USB pump controllers (identification number 62-1240-114 and higher) can

More information

Instruction Manual. HH610-SW Application Software for Portable & Bench Meters

Instruction Manual. HH610-SW Application Software for Portable & Bench Meters Instruction Manual HH610-SW Application Software for Portable & Bench Meters Dear Customer, Thank you for choosing an Omega product. Please read this instruction manual carefully before using the software.

More information

QL-500 QL-560 QL-570 QL-650TD QL-1050

QL-500 QL-560 QL-570 QL-650TD QL-1050 QL-500 QL-560 QL-570 QL-650TD QL-1050 Software installation guide English LB9153001 A Introduction Features P-touch Editor Printer Driver P-touch Address Book (Windows Only) Makes it easy for anyone to

More information

Operating manual. GTL - Configuration tool. Please keep the manual for future use.

Operating manual. GTL - Configuration tool. Please keep the manual for future use. Operating manual GTL - Configuration tool Please keep the manual for future use. V1.00-01 GREISINGER Electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0 Fax +49(0)9402-9383-33

More information

User Manual Software for DSL Digital Speed Switch

User Manual Software for DSL Digital Speed Switch User Manual Software for DSL Digital Speed Switch Software version from 0.9.9 Max-Dohrn-Str. 2+4 D-10589 Berlin Phone +49 (0)30 690 03-0 Fax +49 (0)30 690 03-104 info@baumerhuebner.com www.baumer.com Contents

More information

Instruction manual. testo easyemission Software

Instruction manual. testo easyemission Software Instruction manual testo easyemission Software en 2 General Information General Information This documentation includes important information about the features and application of the product. Please read

More information

Multichannel Data logging

Multichannel Data logging Multichannel Data logging As of version V1.1 Operating manual Bedienungsanleitung EBS 20M / EBS 60M SYSTEM REQUIREMENTS... 3 SCOPE OF SUPPLY... 3 INSTALLATION AND COMMISSIONING... 3 DESIGNATED USE... 3

More information

Device Programming using TRWinProg

Device Programming using TRWinProg Device Programming using TRWinProg Software No.: _490-00416 _490-00416_WIN7 _Program Summary _Safety instructions _System requirements _Program installation _Connecting devices to the PC _Program start

More information

INST.NO. INE-919. DI5000 Setting Software

INST.NO. INE-919. DI5000 Setting Software INST.NO. INE919 DI5000 Setting Software Table of contents 1. Introduction... 1 2. System Requirement... 3 21 Operation Condition of the Software... 3 3 How to Setup... 4 31. Installation... 4 311. New

More information

N2KExtractor. Maretron Data Extraction Software User s Manual

N2KExtractor. Maretron Data Extraction Software User s Manual N2KExtractor Maretron Data Extraction Software User s Manual Revision 3.1.6 Copyright 2017 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com

More information

> EME GUARD. Installation Guide. Date : Our reference :

> EME GUARD. Installation Guide. Date : Our reference : > EME GUARD Installation Guide Date : Our reference : INSTALLATION GUIDE SATIMO Bretagne Zone du Vernis 225 rue Rivoalon 29200 Brest, FRANCE Tél. : +33 (0) 2.98.05.13.34 Fax. : +33 (0) 2.98.05.53.87 Reference:

More information

Installing TAM Air Assistant Software TM

Installing TAM Air Assistant Software TM Installing TAM Air Assistant Software TM Installation Instructions This document describes how to make a new installation of TAM Air Assistant. TAM Air Assistant is intended to be installed on a PC running

More information

Installation Instructions New and Upgrade

Installation Instructions New and Upgrade Wolters Kluwer Financial Services Medici Commercial Lending Documentation System Version 2015.2 Installation Instructions New and Upgrade November 2015 Copyright 2015 Wolters Kluwer Financial Services,

More information

Informatic, Smart Link. Version 3.x POCKET CONTEXT PRO. Multilingual Dictionary for Pocket PC and Pocket PC User's Guide

Informatic, Smart Link. Version 3.x POCKET CONTEXT PRO. Multilingual Dictionary for Pocket PC and Pocket PC User's Guide Informatic, Smart Link Version 3.x POCKET CONTEXT PRO Multilingual Dictionary for Pocket PC and Pocket PC 2002 2002 User's Guide Copyright Notice Copyright 1997-2002 Informatic, Russia and Smart Link Corp.

More information

Operating Instructions / User manual. IRSoft. Version 2.0. Documentation software for ERSA Rework Systems. ERSA GmbH

Operating Instructions / User manual. IRSoft. Version 2.0. Documentation software for ERSA Rework Systems. ERSA GmbH Operating Instructions / User manual IRSoft Version 2.0 Documentation software for ERSA Rework Systems ERSA GmbH Wertheim / Main July 2002 ERSA has taken great care in the preparation of this Users Guide,

More information

Manual Software GLOSS-MONITORING V1.0

Manual Software GLOSS-MONITORING V1.0 Manual Software GLOSS-MONITORING V1.0 for gloss sensors of the GLOSS series This manual describes the installation and operation of the GLOSS-MONITORING PC software version V1.0. The software was developed

More information

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide MULTIFUNCTIONAL DIGITAL SYSTEMS Software Installation Guide 2013 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written

More information

EPLAN License Manager Installation Guide Version Status: 06/2017

EPLAN License Manager Installation Guide Version Status: 06/2017 EPLAN Software & Service GmbH & Co. KG Technical Information Copyright 2017 EPLAN Software & Service GmbH & Co. KG EPLAN Software & Service GmbH & Co. KG assumes no liability for either technical or printing

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick TOOLSTICK C8051F330 DAUGHTER CARD USER S GUIDE 1. Handling Recommendations To enable development, the ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent

More information

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

USB Instruments EasyLogger for PS40M10 Swordfish Help USB Instruments EasyLogger for PS40M10 "Swordfish" Help I EasyLogger for PS40M10 Help Table of Contents Part I Introduction 3 1 Welcome to... EasyLogger for PS40M10 3 2 EasyLogger... Features 4 Part II

More information

Quick Start Guide: RL78G14 Motor Control Starter Kit

Quick Start Guide: RL78G14 Motor Control Starter Kit Document Contents 1.0 Introduction 1 2.0 Board Layout 1 3.0 Stand Alone Demonstration Mode 2 4.0 Installation 3 5.0 Using the GUI 4 6.0 RL78/G14 Programming 6 7.0 RL78/G14 Debugging 7 8.0 Next Steps 8

More information

DriveWizard Plus Instruction Manual

DriveWizard Plus Instruction Manual DriveWizard Plus Instruction Manual To properly use the product, read this manual thoroughly. MANUAL NO. TOEP C730600 20C Table of Contents Safety Symbols and Markings...4 Manual Overview...5 Related Manuals...5

More information

SensView User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0

SensView User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0 SensView User Guide Version 1.0 February 8, 2010 Copyright 2010 SENSR LLC. All Rights Reserved. R001-419-V1.0 TABLE OF CONTENTS 1 PREAMBLE 3 1.1 Software License Agreement 3 2 INSTALLING SENSVIEW 5 2.1

More information

FUTEK USB Software Version User s Manual

FUTEK USB Software Version User s Manual FUTEK USB Software Version 2.0.0.0 User s Manual 10 Thomas, Irvine, CA 92618, USA Toll Free: (800) 23-FUTEK Telephone: (949) 465-0900 Fax: (949) 465-0905 futek@futek.com www.futek.com 2 Table of Contents

More information

WinView. Getting Started Guide

WinView. Getting Started Guide WinView Getting Started Guide Version 4.3.12 June 2006 Copyright 2006 Mincom Limited All rights reserved. No part of this document may be reproduced, transferred, sold or otherwise disposed of without

More information

SUPERSCAN II. Always a step ahead.

SUPERSCAN II. Always a step ahead. SUPERSCAN II Always a step ahead. Operations Manual DEC Automotive Pedro Lozano 4453 Capital Federal C 1417 EEY Argentina Telephone +54 11 4567 1188 / 3994 Fax +54 11 4639 8643 http://www.decautomotive.net/

More information

Testo USB driver Windows 7, Windows 8.1, Windows 10. Application information

Testo USB driver Windows 7, Windows 8.1, Windows 10. Application information Testo USB driver Windows 7, Windows 8.1, Windows 10 Application information 2 General information General information Please take the time to read the Installation Instructions through carefully and make

More information

PHARO User Configuration Software UCS USER MANUAL Rev.0-15/07/ pharo.reer.it

PHARO User Configuration Software UCS USER MANUAL Rev.0-15/07/ pharo.reer.it PHARO User Configuration Software UCS USER MANUAL 8540588 - Rev.0-15/07/2004 www.reer.it pharo.reer.it This document is protected by the law of copyright, whereby all rights established therein remain

More information

EasySense Mac OSX Quick Start Guide

EasySense Mac OSX Quick Start Guide EasySense Mac OSX Quick Start Guide Contents Compatibility... 1 To begin... 2 Recording data... 2 A New recording... 2 Displaying data... 4 Data Value boxes... 4 Show or Hide Channels... 4 Y-Axis display...

More information

RTSoft Ultima. User Manual

RTSoft Ultima. User Manual RTSoft Ultima User Manual RTSoft Ultima User Manual NOVACOR SAS 4 passage Saint-Antoine 92508 Rueil-Malmaison Cedex - France RTSoft Ultima Manual NOVACOR SAS. - All rights reserved User Manual - RTSoft

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

USB-500 Series Getting Started Contents

USB-500 Series Getting Started Contents USB-500 Series Getting Started Contents System requirements and recommendations... 2 USB-501-PRO Safety Agreement... 2 Installing the software... 3 Installing USB-500 Series Data Loggers... 4 Running the

More information

TouchScreen for Display & Panel-PC

TouchScreen for Display & Panel-PC TouchScreen for Display & PanelPC User Manual for Windows 2000 / XP Version: 4.0.2 TouchKit Manual for Win2000/XP v4.0.2 Page 1 CONTENT CHAPTER 1. TOUCH PANEL CONTROLLER... 3 1.1 CONTROLLER... 3 1.2 SPECIFICATIONS

More information

QTrail, 6 Glamis Close Hemel Hempstead, Hertfordshire HP2 7QB Tel: 00 (44) Fax: 00 (44)

QTrail, 6 Glamis Close Hemel Hempstead, Hertfordshire HP2 7QB Tel: 00 (44) Fax: 00 (44) GPRS QTRAIL Vehicle Tracking System User Manual QTrail, 6 Glamis Close Hemel Hempstead, Hertfordshire HP2 7QB Tel: 00 (44) 1442 232434 Fax: 00 (44) 1442 232366 Email: enquiries@qtrail.com QTrail 2005 Every

More information

Touchscreen Driver Release Note

Touchscreen Driver Release Note Touchscreen Driver Release Note Touchbase UPDD If you have purchased a CTC PowerStation or Industrial PC that has a touchscreen and that runs under a Windows operating system, your touchscreen driver is

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick TOOLSTICK C8051F560 DAUGHTER CARD USER S GUIDE 1. Handling Recommendations To enable development, the ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent

More information

FM300 Front Panel. User s Manual. March 2005

FM300 Front Panel. User s Manual. March 2005 FM300 Front Panel User s Manual March 2005 Macintyre Electronic Design Associates, Inc. 43676 Trade Center Place, Suite 145 Dulles, VA 20166 Disclaimer of Warranty FM300 Front Panel NO WARRANTIES OR CONDITIONS:

More information

testo Comfort Software Professional 4 Instruction manual

testo Comfort Software Professional 4 Instruction manual testo Comfort Software Professional 4 Instruction manual 2 1 Contents 1 Contents 1 Contents...3 2 About this document...5 3 Specifications...6 3.1. Use...6 3.2. System requirements...6 4 First steps...7

More information

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009 AWLaunch Software Manual Version 1.2 Last Revised April 27, 2009 All contents in this manual are copyrighted by ArWest Communications. All rights reserved.the information contained herein may not be used,

More information

Quick Start Guide GV-VMS

Quick Start Guide GV-VMS Quick Start Guide GV-VMS Thank you for purchasing GV-VMS. This guide is designed to assist the new user in getting immediate results from the GV-VMS. For advanced information on how to use the GV-VMS,

More information

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide MULTIFUNCTIONAL DIGITAL SYSTEMS Software Installation Guide 2013 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written

More information

StrikeRisk v5.0 Getting started

StrikeRisk v5.0 Getting started StrikeRisk v5.0 Getting started Contents 1 Introduction 1 2 Installing StrikeRisk 2 7 2.1 System Requirements 2 2.2 Installing StrikeRisk 2 5 2.3 Installation troubleshooting 6 2.4 Uninstalling StrikeRisk

More information

Digivu Quick Start Guide. Digivu User Instructions

Digivu Quick Start Guide. Digivu User Instructions Digivu Quick Start Guide Digivu User Instructions Page - 2 Digivu User Instructions Page - 3 Table of contents Quick Start Guide 2 Digivu Functions 6 Connecting to a Vehicle Unit 6 Digivu Internal Memory

More information

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON

TROVIS-VIEW 4 Software TROVIS Operating Instructions EB 6661 EN. Electronics from SAMSON TROVIS-VIEW 4 Software TROVIS 6661 Operating Instructions Electronics from SAMSON EB 6661 EN Edition January 2015 Definition of signal words DANGER! Hazardous situations which, if not avoided, will result

More information

MYOB EXO EMPLOYER SERVICES

MYOB EXO EMPLOYER SERVICES MYOB EXO EMPLOYER SERVICES NZ Edition 2012.02 Release Notes EXO EMPLOYER SERVICES MYOB ENTERPRISE SOLUTIONS Important Notices This material is copyright. It is intended only for MYOB Enterprise Solutions

More information

JDS7. Label design software USER MANUAL

JDS7. Label design software USER MANUAL Label design software USER MANUAL IMPORTANT NOTES Important Notes Copyright The present document and the described software therein belong to the company Allen Coding. All rights remain reserved. Reproduction

More information

4TimeWeb Short Manual NEXT! s.c. S.Piela, B.Dryja

4TimeWeb Short Manual NEXT! s.c. S.Piela, B.Dryja 4TimeWeb Short Manual 2013 NEXT! s.c. S.Piela, B.Dryja 4TimeWeb Short Manual 2013 NEXT! s.c. S.Piela, B.Dryja All rights reserved. No parts of this work may be reproduced in any form or by any means -

More information

Digi-Pas Innovation & Technology Driven

Digi-Pas Innovation & Technology Driven Digi-Pas Innovation & Technology Driven PC SYNC PROFESSIONAL SOFTWARE USER MANUAL Model: DWL2000XY REVISION 2.00 www.digipas.com Note: Contents in this instruction manual is continuously updated, please

More information

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str.

FLOWgate500. Software Manual. Software Manual FLOWgate500 Release 2.2. Revision number: V2.2. Manufacturer: SICK AG. Erwin-Sick-Str. FLOWgate500 Software Manual Software Manual FLOWgate500 Release 2.2 Revision number: V2.2 Manufacturer: SICK AG Erwin-Sick-Str.1 D-79183 Waldkirch Germany Place of manufacture: SICK Engineering GmbH Bergener

More information

This course will introduce the user the Windows 7 Operating System by covering the desktop, start button, task bar and the Computer section

This course will introduce the user the Windows 7 Operating System by covering the desktop, start button, task bar and the Computer section This course will introduce the user the Windows 7 Operating System by covering the desktop, start button, task bar and the Computer section previously known as My Computer. The user will be introduced

More information

1 Minimum system requirements

1 Minimum system requirements Metrohm AG CH-9100 Herisau Switzerland Phone +41 71 353 85 85 Fax +41 71 353 89 01 info@metrohm.com www.metrohm.com Installation tiamo 2.x 1 Minimum system requirements Operating system RAM Memory Serial

More information

Quick Start Guide Vodafone Mobile Connect USB Stick

Quick Start Guide Vodafone Mobile Connect USB Stick Quick Start Guide Vodafone Mobile Connect USB Stick Welcome 2 What can I do with it? 3 Set up your USB Stick 4 Run the software 5 Configuration 6 Make a connection 7 USB Stick status 7 Other settings 8

More information

RSC2 Manual. Road Sensor Control Software for Retrometer LTL-X

RSC2 Manual. Road Sensor Control Software for Retrometer LTL-X Manual Road Sensor Control Software for Retrometer LTL-X Venlighedsvej 4 2970 Hørsholm Denmark Tel. (+45) 72 19 40 00 Fax (+45) 72 19 40 01 DISCLAIMER The information contained in this document is subject

More information

Manual SmartGraph for Humlog 10

Manual SmartGraph for Humlog 10 Manual SmartGraph for Humlog 10 State: 10.12.2001 Version: V1.0 1 1 INTRODUCTION TO SMARTGRAPH... 4 1.1 Manage, Configure... 4 1.2 The Programme Interface... 4 1.2.1 Graphs... 5 1.2.2 Table... 6 1.2.3

More information

SFRA 5.2 Marketing Release Note

SFRA 5.2 Marketing Release Note SFRA 5.2 Marketing Release Note Doble Engineering Company 85 Walnut Street Watertown, Massachusetts 02472-4037 (USA) www.doble.com 72A-2604-01 Rev. D 07/2011 Limitation in Liability The limitations on

More information

PC Software R&S FS300-K1

PC Software R&S FS300-K1 Copyright 0 Copyright Copyright Licence Agreement Rohde & Schwarz grants you the right to install the R&S FS300-K1 software package on one or more PCs of your choice. The licence included in the software

More information

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151 USER S MANUAL Contents 1. Main Features... 4 A Variety of Display Formats...4 Simple and Easy to Use...5 Thumbnail Waveform Display...5 Export to Direct Excel File Function...6 CSV File Batch Conversion...6

More information