ANNEXURE-I SR. NO. TOPIC PAGE NO.
|
|
- Lydia Bryant
- 5 years ago
- Views:
Transcription
1 Tender no. MM/KAIGA1-4/CAPKGS1-4/ SR. NO. TOPIC PAGE NO. Scope Technical Specifications For Computing Hardware to 4.0 Pre-Dispatch Inspection Warranty Qualifying Criteria for Bidders Delivery and Installation Schedule Compliance 8 To 10 0
2 Scope The scope of work covered under this specification comprises of supply, delivery, inspection, installation, commissioning and On-Site Comprehensive Warranty of following hardware for Online Decision Support system at NPCIL KGS. Item Sr. No. Description Total Quantity 1. Workstation 1 Nos.. LED Backlit Monitor 1 Nos Port SMS Modem Nos. Safe Delivery of items to NPCIL Stores, KGS, Kaiga Installation & Commissioning shall be carried out as per the instructions of EIC, IT. Supply of power cables, plug and all necessary cables to interconnect various peripherals. Supply of software license for Windows 10 Professional 64 bit Operating System. Part replacement (including plastic parts or any other parts) and breakdown maintenance of the system during warranty period shall be carried out without any charges. 1
3 1.0 Technical Specifications for Hardware Item No. 1.0 Workstation for Online Decision Support System with following essential configuration: Qty: 1 Sets Workstation Specifications Processor Intel Xeon 4-Core Processor E3-100 v3 family (3.4GHz/8MB/HT) or Higher Chipset Intel C6 Chipset Form Factor Memory Tower 3GB DDR3-1600, minimum 4 DIMM slots Storage Drive x 3.5" HDD bays (internal), x 5.5" drive bays (external/internal) Bays SATA DISK x.0 TB Hot swappable SATA 700 rpm 6Gb/s 3.5" HDD in RAID 1 Optical Drives DVD+/- RW SuperMulti (SATA) Optical Drive Audio High Definition Realtek HD ALC6/Realtek HD ALC1/ Realtek ALC1150 audio with internal speaker or better Slots Minimum 1 PCI Express3.0 x16 slots Minimum 3 PCI Express.0 slots or more I/O Ports 4 USB 3.0, USB.0, Headphone, 1 Microphone, 1 Audio Line-In, 1 Audio Line-Out Input Devices USB optical scroll mouse Keyboard USB standard keyboard Graphics card NVIDIA Quadro K60 GB Graphics/ NVIDIA Quadro K000 GB Graphics or better Operating Genuine Windows 10 Professional 64-bit with recovery media System Compliance RoHS Certification FCC/CE, UL Listed / EN 60950/ BIS135/IEC Compliant Power Supply Minimum 400W power supply USB Hard 1TB Backup Plus Portable Hard Drive Super Speed USB 3.0. Drive Industry PCIe.0 and 3.0, UEFI or better, USB 3.0 and USB.0 Support Standard Support Warranty 3 years onsite comprehensive warranty Note: 1. Published Brochure/Catalogue of the model offered shall be submitted along with the offer.
4 Item No..0 LED backlit Monitor with following essential features : Qty: 1 Nos. Display Display Native Resolution Aspect Ratio 16:9 Viewing angle Brightness (typical Contrast Ratio (typical) Response Time (Typical) Certification Input Power Ports Internal Player (Embedded H/W) Accessories Warranty Minimum 55 IPS (in-plane switching) LED Backlit LCD Display 190 x1080 Up to178 horizontal/178 vertical 350 nits or better 1000:1 or better Upto 16ms UL / EN60950/ IEC 60950/BIS135, FCC Compliant, Energy Star 5.0 or better VAC, 50Hz Input/Output: HDMI, DVI-D, RJ45, USB, RS3C(In/Out), Buil-in Speaker (10W + 10W) Embedded media player through USB support playing 1080P video, JPEG, Supports USB.0 1. Video and audio cable length 15 meters to connect Workstation and Monitor.. Suitable Stand / Wall Mounting equipment for Monitor shall be provided at the time of installation of Monitor. 3 Years Comprehensive On-site warranty Note: 1. Published Brochure/Catalogue of the model offered shall be submitted along with the offer. 3
5 Item No Port intelligent SMS Modem for Online Decision Support System with One year on-site comprehensive warranty as per following specification : Qty: Nos. Item Hardware Interface Modem SIM Connector Antenna Connector Universal Input Power Supply Operating Environment Features Description Network: 10/100 BaseT Connector: RJ-45 Ethernet connection / DE9 Quad-band GSM 850/900/1800/1900 MHz Standard 3V SIM Receptacle RF Antenna: 50 ohm SMA (female) Input: V AC, a, 50/60 Hz Temperature range: +3 0 to 10 0 F (0 0 to C) Humidity range: 0-90% non-condensing Web-based configuration and management Certification CE Mark, R&TTE EMC: FCC Part 15,, 4; IC RSS 13, 133, 10; EN 550, EN 5504, EN , EN , EN , ACIF S04.1, ACIF S04.3 Safety: UL , cul , IEC , AU/NZS Network: PTCRB Warranty ONE Years Comprehensive On-site warranty Note: 1. Published Brochure/Catalogue of the model offered shall be submitted along with the offer. 4
6 .0 Pre-Dispatch Inspection Manufacturer shall have the following facilities: A. Licensed version of suitable diagnostic software to test hardware components such as motherboard and its components like chipset, DNA controller, memory controller, input/output controller and availability of bad sectors on hard disk drives. It should also be possible to check serial, parallel & USB ports using special loop back connectors. Suitable software should also be available for checking the keyboard and for bench marking other software components. B. Suitable pattern generator software to check the monitors of different characteristic. Following Quality tests (Tentative) shall be carried out at the supplier s premises on all Workstations and reports shall be submitted to NPCIL representative. NPCIL representative may carry out the tests on Workstation. Final Quality test shall be mutually agreed by NPCIL and supplier. 3.1 Visual inspection: Visual inspection shall be carried out to check that the make and model of the components and the subsystems are as per the P.O. or better. 3. Configuration Test: Suitable test programs shall be run on Workstation to check/ confirm that hardware configuration is as per the P.O. 3.3 Burn Test: Burn test shall be conducted on Workstation for at least 100 hrs. 3.4 Functional Tests for Workstation a. RAID Configuration Configure RAID-1 in the hard disks. Remove one hard disk while some action like copy is going on to demonstrate the functionality of RAID-1. The data shall not get corrupt or the service shall not be interrupted b. Hot Swap Remove any hard disk while server is running and replace. The same shall be reflected and the space shall be shown accordingly without a break in availability. c. DVD/CD-RW combo drive and USB drive Functioning of DVD/Combo drive and USB drive is to be demonstrated. 5
7 3.0 Warranty The system shall carry a comprehensive onsite maintenance warranty of three years for workstation, Monitor and one year for SMS Modem from the date of Final Acceptance. The scope of warranty shall include repair or replacement of all defective parts or failed components including plastic parts, break down maintenance, installing/re-installing of software and installation of operating systems patches without any charges. The software shall be bug free. If any bug is found in the software, the supplier shall ensure correction in a reasonable agreed time. During warranty period, if any hard disk of the Workstation is corrupted or is unrepairable at NPCIL premises, it is to be replaced with new hard disk by the vendor without any charges. In case the vendor requires the faulty hard disk back, the same will be returned after degaussing due to security/privacy regulations. Warranty period starts from the date of final acceptance. The vendor shall make their own arrangement for transport and labor for maintenance of the systems during Warranty period. During Warranty period without affecting Warranty conditions specified in, 1. NPCIL reserves the right to install any licensed software on the machines and the supplier shall install the same without any charges.. NPCIL reserves the right to install any standard hardware (including additional RAM, add on cards, HDD, DVD writer etc.) procured from any sources. The same shall be installed under the supervision of the supplier. 3. During warranty period, in case any user wants to install any other licensed operating software, it shall be installed. 4.1 Warranty Extension ( for Workstation & Monitor) During the Warranty period, break-down maintenance call should be attended within next working day of NPCIL. The total down time of any Workstation / Monitor shall not exceed 16 hours in a month. During the warranty period if any Workstation / Monitor is continuously down for more than 16 hours in a month, then following warranty extension shall apply for each such incidence: > 16 Hrs to 4 Hrs Extension by 4 days > 4 Hrs to 3 Hrs Extension by 6 days Beyond 3 Hrs. Extension by 15 days Note: i. All down time hours are counted between 9.30 AM and 5:30 PM on all working days of NPCIL. ii. Above warranty extension clause shall apply during each extended period also. 6
8 4.0 Qualifying Criteria for Bidders : AS PER NIT 5.0 Delivery and Installation Schedule: Supply: Items shall be delivered at NPCIL KGS Stores, KGS, Kaiga within 10 Weeks from the date of Purchase Order Installation & Commissioning: Items shall be installed and commissioned within 4 weeks from the date of intimation of site readiness. 7
9 6.0 Compliance Technical compliance list to be filled and submitted by the bidder along with the offer: Item No. 1.0 Workstation for Online Decision Support System with following essential configuration: Item Description Complied Yes/No Make & Model To be specified by the vendor Processor Chipset Form Factor Memory Intel Xeon 4-Core Processor E3-100 v3 family (3.4GHz/8MB/HT) or Higher Intel C6 Chipset Tower 3GB DDR3-1600, minimum 4 DIMM slots Storage Drive x 3.5" HDD bays (internal), x 5.5" drive bays Bays (external/internal) SATA DISK x.0 TB Hot swappable SATA 700 rpm 6Gb/s 3.5" HDD in RAID 1 Optical Drives DVD+/- RW SuperMulti (SATA) Optical Drive Audio High Definition Realtek HD ALC6/Realtek HD ALC1/ Realtek ALC1150 audio with internal speaker or better Slots Minimum 1 PCI Express3.0 x16 slots Minimum PCI Express.0 slots or more I/O Ports 4 USB 3.0, USB.0, Headphone, 1 Microphone, 1 Audio Line-In, 1 Audio Line-Out Input Devices USB optical scroll mouse Keyboard USB standard keyboard Graphics card NVIDIA Quadro K60 GB Graphics/ NVIDIA Quadro K000 GB Graphics or better Operating Genuine Windows 10 Professional 64-bit with recovery System media Compliance RoHS Certification FCC/CE, UL Listed / EN 60950/ BIS135/IEC Compliant Power Supply Minimum 400W power supply USB Hard 1TB Backup Plus Portable Hard Drive Super Speed USB 3.0. Drive Industry PCIe.0 and 3.0 Compliant, UEFI, USB 3.0 and USB.0 Standard Support Support Warranty 3 years onsite comprehensive warranty Published Brochure / Catalogue attached 8
10 Item No..0 IPS LED backlit Monitor with following essential features : Qty: Nos. Item Description Complied Yes/No Make & Model To be specified by the vendor Display Display Native Resolution Aspect Ratio 16:9 Viewing angle Brightness (typical Contrast Ratio (typical) Response Time (Typical) Certification Input Power Ports Internal Player (Embedded H/W) Accessories Warranty Minimum 55 IPS (in-plane switching) LED Backlit LCD Display 190 x1080 Up to178 horizontal/178 vertical 350 nits or better 1000:1 or better Upto 16ms UL60950 / EN60950 / IEC 60950/BIS135, FCC Compliant, Energy Star 5.0 or better VAC, 50Hz Input/Output: HDMI, DVI-D, RJ45, USB, RS3C(In/Out), Buil-in Speaker (10W + 10W) Embedded media player through USB support playing 1080P video, JPEG, Supports USB.0 1. Video and audio cable length 15 meters to connect Workstation and Monitor.. Suitable Stand / Wall Mounting equipment for Monitor shall be provided at the time of installation of Monitor. 3 Years Comprehensive On-site warranty Published Brochure / Catalogue attached 9
11 Item No Port intelligent SMS Modem for Online Decision Support System with One year on-site comprehensive warranty as per following specification : Qty: 4 Nos. Item Description Complied Yes/No Hardware Interface Network: 10/100 BaseT Connector: RJ-45 Ethernet connection / DE9 Modem Quad-band GSM 850/900/1800/1900 MHz SIM Connector Antenna Connector Universal Input Power Supply Operating Environment Features Standard 3V SIM Receptacle RF Antenna: 50 ohm SMA (female) Input: V AC, a, 50/60 Hz Temperature range: +3 0 to 10 0 F (0 0 to C) Humidity range: 0-90% non-condensing Web-based configuration and management Certification CE Mark, R&TTE EMC: FCC Part 15,, 4; IC RSS 13, 133, 10; EN 550, EN 5504, EN , EN , EN , ACIF S04.1, ACIF S04.3 Safety: UL , cul , IEC , AU/NZS Warranty Network: PTCRB ONE Year Comprehensive On-site warranty Published Brochure / Catalogue attached 10
12 I SR. NO. TOPIC PAGE NO. 1.0 Scope 1.0 Contents : 3.0 Applicable compliance Standards 4.0 Technical requirement: Functional requirement: Submittals after placement of order for our review and approval Tests 5 Guaranty / Defect liability period Qualifying Criteria Data to be furnished by supplier TENTATIVE QUALITY ASSUTANCE PLAN (QAP) 7-9 0
13 I 1. Scope: This specification covers the design, material, construction features, manufacture, inspection and testing at the manufacturer s works, packing, transportation and delivery at the place of installation, erection and commissioning of UPS along with battery of required capacity complete with all accessories and features as per specification. Sl Item description Location of No Installation 1 1 phase 30V, 50 Hz Kaiga UPS for 1kVA Load Generating with backup time of Station 480 Minutes along with required capacity VRLA battery and other accessories. Quantity 1 Number UPS system shall comprise IGBT based rectifier & inverter, associated controls, external communication, indication, alarm, protection, battery bank etc. and with all accessories to meet the specific performance and operational requirement as stated in the specification. Manufacturer/ supplier shall indicate capacity of UPS. External/Additional charger for batteries is acceptable. It is not the intent to specify herein all detail of design and construction of UPS system, however system shall conform in all respect to high standard of engineering, design, workmanship and capable of performing as per intent of specification. Major component like battery, switches, devices etc shall be of reputed make and subject to NPCIL approval. 1
14 I. Contents :.1 Applicable Compliance Standards. Technical requirement..1 Input details.. UPS particulars to be met by manufacturer/ supplier...1 Rectifier... Battery...3 Inverter...4 General.3 Functional requirement:.4 Submittals after placement of order for our review and approval.5 Tests.5.1 Routine tests on UPS at the place of supplier s premises..5. Installation and commissioning tests at place of installation.6 Guaranty / Defect liability period.7 Qualifying Criteria.8 Data to be furnished by supplier 3. Applicable compliance Standards All components shall comply the relevant standards i.e. brochure must indicate these standard compliance to offered product. Some of the standards are listed below: Sl no Title Standard 3.1 Safety EN / IEC EMC Emission EN / IEC Information technology equipment - IEC / EN Safety - Part: General requirements 3.4 Compatibility level for low voltage conducted disturbance and signaling in public low voltage power supply system IEC /EN Other National or international standards are acceptable if they are established to equivalent or superior to the listed standards. 4. Technical requirement: 4.1 Input details: Input voltage 1 phase, wire, 30 V ± 10% 4.1. Input frequency 50 Hz with ± 5% variation Grounding Effectively grounded Ambient temperature 40 deg C Relative humidity 5 to 90% non-condensing
15 I 4. UPS particulars to be met by manufacturer/ supplier: 4..1 Rectifier Input voltage Shall be suitable for connecting to input supply described above DC output voltage Common DC voltage link shall be suitable for the inverter and VRLA type battery charging. Battery terminal float voltage shall not be more than.35v per cell. Manufacturer shall decide the voltage range for smooth operation of UPS under normal operation as well as under input power supply/ rectifier failure Total current harmonics injection to Less than 8% input on linear load (THDi) 4.. Battery Back-up 480 Minute on Full Load 4... Type of battery Sealed maintenance free valve regulated lead acid battery No of cells To be decided by UPS manufacturer Capacity To be decided by manufacturer based on duty cycle provided by purchaser Plates Pasted construction Separator The separator used shall be of glass mat having high acid absorption capacity, resistance to sulphuric acid and good insulating property Compliance to applicable standard IS Mounting Integral part of UPS or Separately rack mounted 4..3 Inverter DC input voltage Common DC link voltage shall be suitable for the inverter and VRLA type battery charging. Battery terminal float voltage shall not be more than.35v per cell. Manufacturer shall decide the voltage range for smooth operation of UPS under normal operation as well as under input power supply/ rectifier failure AC output voltage 1 phase, 30 V, 50 Hz Quality of output voltage Pure sinusoidal Frequency stability/ regulation ±3Hz of nominal line frequency Crest factor > 3: General Overall 100% load >= 90% (Online Mode) >= 80% (On Battery) Overload capacity 101% - 10% for 1 sec, 10% - 140% for sec, > 140% UPS Shuts Down 3
16 I Output voltage variation in steady <=% state condition for change in source voltage as well as battery voltage Load Power factor range Noise 1 Mt.distance <=6 db Short circuit capability Manufacturer shall indicate the short circuit capability. Protection coordination with outgoing feeder and device shall be done in order to avoid tripping of entire ups for fault in a particular outgoing feeder EMI requirement As per standard Protection Manufacturer shall indicate list of protection (IP0/EN6059) Alarm Audible/ beep sound and Visible Alarm for Faults/ any other event decided by manufacturer Metering Minimum- LCD display of Voltage / current and frequency Communication Interface port with RS3 and Ethernet SNMP card with auto shut down software for windows. The software loaded on the windows workstation should detect the UPS input power failure signal and should be able to trigger the shutdown of the workstation at a later time as per the configuration. In case the power is restored before the start of the shutdown process, the software on detecting the power restore signal should be able to stop the timer so that the server should not be shutdown. The UPS should have the network interface through which the power failure /power restore signal is transmitted to the Workstation. Note: UPS with External/additional charger for batteries is acceptable. 5. Functional requirement: UPS shall be dual conversion type. Input supply first shall be converted to DC by IGBT based rectifier and then DC output shall be converted to AC by IGBT based inverter. In the event of supply failure or rectifier failure, battery will act as input to inverter. Supplier shall indicate all protection, control and monitoring function of UPS. Provision shall be made for grounding connection of UPS. 6. Submittals after placement of order for our review and approval. 4
17 I Battery sizing calculation, UPS device sizing calculation. Soft copy of operation and maintenance manual. 7. Tests Successful bidder has to provide their detailed Quality Assurance Plan (QAP).The QAP shall be prepared to ensure that the specifications mentioned here are to be tested for quality assurance. A typical Quality Assurance plan (QAP) is attached for your reference in Table-I. Required test procedure for test given in clause no 7.1 shall be submitted for purchaser approval within 0 days from the date of purchase order. 7.1 Following routine tests on UPS shall be conducted in presence of NPCIL representative at the place of supplier s premises. a) Visual inspection, workmanship, dimensional check. b) Steady state output voltage and frequency variation for 0 to 100% load variation and supply voltage variation. c) Interruption free operation of load after tripping of input supply. d) Measurement of efficiency at 100% load. e) Test for shutting down Desktop/ Server. f) Test for LCD display for all parameters g) Test on battery as per standard 7. Installation and commissioning tests at place of installation a) Check installation of UPS as per installation procedure. b) Functional tests c) Guarantee test for seven days continuous running with available loads. 8. Guaranty / Defect liability period UPS supplied as per specification shall be guaranteed as per General Condition of contract for supply of indigenous store. 9. Qualifying Criteria : AS PER NIT. 5
18 I 10. Data to be furnished by supplier Sl No Particulars 10.1 Make and type and rating of UPS 10. Input voltage variation 10.3 Input frequency variation 10.4 DC voltage variation 10.5 Any component derating is used 10.6 Efficiency at full load >= 90% (Online Mode) 10.7 Efficiency at full load >= 80% (On Battery) 10.8 List of all alarms 10.9 List of all metering Communication hardware (including RS3 and Ethernet SNMP card) and software for automatic shutdown of Windows PC/ Workstation List of all protections 10.1 Overload capacity of UPS 101% - 10% for 1 sec, 10% - 140% for sec, > 140% UPS Shuts Down Compliance to EMI/ EMC (EN / IEC 6040-), Brochure indicating these standard shall be submitted Type of battery (Sealed maintenance free valve regulated lead acid battery) Total harmonic distortion at input should be Less than 8% Quality of output voltage should be Pure sinusoidal Make of battery Design Factor Aging factor 10.0 End Cell Voltage (ECV) 10.1 Inverter Efficiency 10. Backup Time should be 480Minutes 10.3 Temperature correction Factor at 7 Degree 10.4 K factor for 480 Minutes 10.5 No of cell 10.6 Ah capacity 10.7 Degree of protection provided by enclosure 10.8 Inverter Efficiency Technical catalogue/ Brochure must be submitted 6
19 I Note:- AH capacity shall be calculate/ verified as per following :- Minimum Aging factor 1.5 will be taken for calculation, if value is provided less than 1.5. Minimum Design factor 1.1 will be taken for calculation, if value is provided less than 1.1. Power factor for above calculation 0.8 shall be considered for calculation. TABLE-1 Sl N o. 1 Specificatio n 1. Hardware physical check for damages etc. Performance requirement 3. Performance requirement TENTATIVE QUALITY ASSUTANCE PLAN (QAP) Characteri Type of Classification Acceptanc stics check e Norms Visual inspection, workmanship, dimensional check functional Steady state output voltage and frequency variation for 0 to 100% load variation functional and supply voltage variation Interruption free operation of load after tripping of input supply. As per Specification. Output Voltage will be Checked via Multimeter with Load variation from 0 to Full Load. Variation should be max of ±% of rated output voltage Put Some load (On Desktop/ Server) on the UPS systems, then switch off supply to UPS and observer the uninterrupted / continuous operation of Desktop and again switch on supply to the UPS and check the retransfer. 8 As per requireme nt specificati on As per requireme nt/manufa cturer s data sheets As per requireme nt/manufa cturer s data sheets Format of Records 9 3/ TC 3/ TC 3/ Agency P W V
20 4. Performance requirement 5. Performance Requirement functional functional I Measurement of efficiency at 100% load Test shutting down Desktop/ Server. for of Put 100% load on system, check the output & input power in kw or W. (Output kw/input kw)*100 will give the efficiency and should be 90% Installing the auto shutdown software /Application. Shutting down time shall be configured. Shutdown shall be demonstrated as per configured time. As per requireme nt/manufa cturer s data sheets As Per Requireme nt/ Manufactu rers data sheet TC 3/ TC 3/ Performance requirement functional Test for LCD display for all parameters All parameter like input, output, Battery can be viewed through LCD Display. Input Voltage, Input frequency, Input Current/ Power, Output Voltage, Output frequency, Output power/current, Battery voltage. As per requireme nt / manufactu rer s data sheets Test Reports 3/ 1 1 8
21 7. Performance requirement functional Test on battery as per standard I Will keep the required load as per calculation sheet and switch off the input power supply to UPS & Batteries should give the required backup as stated in the calculation sheet. In order to check the charging current, need to switch on the input of the UPS after discharging the batteries, the max charging current 10% of total battery AH. As per requireme nt/manufa cturer s data sheets TC 3/ 1 1 Note: C10 & High rate Discharge shall be conducted. LEGENDS: MA-MAJOR 1.NPCIL P-Performed by TC-TEST CERTIFICATES.Manufacturer W-Witnessed by 3.Third Party V-verified by 9
Product Specifications
Product Specifications Models: USC-10001, USC-10002 USC-20001, USC-20002 USC-30001, USC-30002 Guide Specification for UniStar C Series Rack/Universal 1, 2, 3Kva Single-Phase, On-Line Double Conversoin
More information1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA
The SR series on line double conversion UPS with full time Digital Signal Processor control technology is the perfect solution for mission critical users who demand high reliability, availability and performance
More informationREQUEST FOR PROPOSAL FOR SUPPLY & INSTALLATION OF DESKTOPS AND LAPTOPS. Supply & installation of DESKTOPS and LAPTOPS in the following location.
REQUEST FOR PROPOSAL FOR SUPPLY & INSTALLATION OF DESKTOPS AND LAPTOPS General Scope of Work: Supply & installation of DESKTOPS and LAPTOPS in the following location. Location of Installation: ISI Kolkata,
More informationNATIONAL INSTITUTE OF TECHNOLOGY, TIRUCHIRAPPALLI INVITATION FOR QUOTATION. TEQIP-III/2017/NITT/Shopping/44
Under Technical Education Quality Improvement Programme Phase-III of Government of India Phone 9444170638 Fax 91-(0)431-2500133 Internet www.nitt.edu NATIONAL INSTITUTE OF TECHNOLOGY, TIRUCHIRAPPALLI-620
More informationCORRIGENDUM IN TENDER NO. HWT
BLOCK NO.-, 8 TH FLOOR, UDYOG BHAVAN, SECTOR-, GANDHINAGAR CORRIGENDUM IN TENDER NO. HWT02036353 Form no. T2 (TECHNICAL MINIMUM SPECIFICATIONS) SECTION ( PCs & other items) Sr. No. Item ) PC ( Intel Core
More informationSd/- REGISTRAR RGUHS TENDER NOTIFICATION
Rajiv Gandhi University Of Health Sciences, Karnataka 4 th T Block, Jayanagar, Bangalore 560 04 ------------------------------------------------------------------------------------------------------------------------------------
More informationPOWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA)
POWERVAR SECURITY PLUS SERIES DETAILED UPS SPECIFICATION (8kVA 10kVA) A55-00017 SEC PLUS 8-10 KVA MAREKTING SPECS REV. A 9/10 8kVA, 10kVA POWERVAR Isolated On-Line UPS Specifications Index 1.0 General
More informationQualifying Minimum Requirements
REQUEST FOR PROPOSAL FOR SUPPLY & INSTALLATION OF DESKTOP General Scope of Work: Supply & installation of DESKTOP in the following location. Locations of Installation: ISI kolkata, 203 B.T. Road, Kolkata
More informationTHOR Modular. Modular UPS system. Online double-conversion Scalable Decentralized Parallel. Modular. 10, 20, 30, 40kVA modules kVA systems
Power Supplies Modular THOR Modular Modular UPS system Online double-conversion Scalable Decentralized Parallel Modular 10, 20, 30, 40kVA modules 10-520kVA systems Power factor 1.0 at 10/20kVA/kW modules
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30
INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/30 29-Aug-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationLiebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection
Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection Liebert GXT4 UPS, 5kVA-10kVA Systems: Best Protection for Critical Network Applications Today s converged networks require increased availability
More informationMP7. Uninterruptible Power Supply
Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationThe quality management system is. Mitsubishi Electric Corporation Kobe Works has been approved to ISO9001:2000.
7011A_JAN_2011_REVISED_88776_A_7011A 2/1/11 12:57 PM Page 1 7011A Series (6kVA to ) Advantages UNINTERRUPTIBLE POWER SUPPLIES Advanced IGBT technology in both the rectifier and inverter True double conversion
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R MP7
Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationINVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/30
INVITATION FOR QUOTATION TEQIP-III/2018/uceo/Shopping/30 27-Dec-2018 To, Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationNEW AMENDMENTS (2) TO ICT TENDER DOCUMENT
NEW AMENDMENTS (2) TO ICT TENDER DOCUMENT AMENDMENT TO SECTION VII Amended Technical Specifications of Computers and UPS for ICT in Schools. Servers : Server Configuration ( Intel Based) CPU: Processor
More informationSmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out
SmartOnline 200-240V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA)
More informationProduct Snapshot. The Powerware Uninterruptible Power System. Product Focus
Powerware 9120 Uninterruptible Power System Product Focus Product Snapshot Power Rating: 700-3000VA Voltage: 120 and 230 Vac Frequency: 50/60 Hz (auto-sensing) Configuration: tower Features True double-conversion
More informationIDBI Bank Limited Corrigendum to the RFP For Procurement of Treasury PCs RFP ref. no: IDBI/PCELL/RFP/ /017 dated : 30-Oct-2015
RFP Page Section / Clause/Para 1 6 Document Control Sheet 2 6 Document Control Sheet Existing clause Schedule for Receipt of Bids: Date 23/11/2015 Time 16:00 hours Schedule for Opening of Technical Bids
More informationStandard Specifications provided by the Director, ICSU for purchasing of general purpose of Computers, Photocopy Machines and Printers
Standard Specifications provided by the Director, ICSU for purchasing of general purpose of Computers, Photocopy Machines and Printers Branded Desktop Computers ( 01) -Requirement (Yes / No) Country of
More informationNational Electric Power Regulatory Authority NEPRA. Purchase of 01 UPS for Datacenter Servers and 19 UPSs for Individual s Desktop Computers
National Electric Power Regulatory Authority NEPRA Purchase of 01 UPS for Datacenter Servers and 19 UPSs for Individual s Desktop Computers NEPRA Bid No. 03/2015 Bid Serial No. Dated: Name of the firm
More informationSMARTONLINE E3 UPS SYSTEMS
SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,
More informationLiebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity
Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications AC Power For Business-Critical Continuity Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today
More informationSmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output
SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output MODEL NUMBER: SU10KRT3/1X Highlights 10,000VA (10kVA) SmartOnline 6U rack/tower UPS 3 phase, 4-Wire + Ground,
More informationIntelligent On-Line UPS
Intelligent On-Line UPS Intelligent On-Line UPS Unity Input Power Factor Single-Chip Microprocessor Control Wide Input Voltage Range Pure Sinewave Output Smart RS-232 Communication Interface External Battery
More information(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)
Section 16306 50/60-HERTZ (HZ) SOLID STATE FREQUENCY CONVERTER Index PART 1 GENERAL PART 2 PRODUCTS 1.1 References 2.1 Frequency Converters 1.2 Factory Tests 2.2 Conduit and Fittings 1.3 Submittals 2.3
More informationGAUHATI UNIVERSITY INSTITUTE OF SCIENCE AND TECHNOLOGY GopinathBordoloi Nagar, Guwahati Telephone No.:
GAUHATI UNIVERSITY INSTITUTE OF SCIENCE AND TECHNOLOGY GopinathBordoloi Nagar, Guwahati-781014 Telephone No.: 9954028440 www.gauhati.ac.in NO.: GUIST/2017-18/04 Date: September 23, 2017 Notice Inviting
More informationARP992/ ARP992-B User Reference Manual
ARP992/ ARP992-B User Reference Manual Specifications Model No ARP992 ARP992-B CPU Intel Core i5-7440eq, 2.90GHz Processors Option: Intel Core i7-7820eq, 3.0 GHz Chipset Intel 7th Gen. Core i5 /i7 processors
More informationODISHA GRAMYA BANK Information Technology Department Head Office, Gandamunda, P.O.-Khandagiri, Bhubaneswar
ODISHA GRAMYA BANK Information Technology Department Head Office, Gandamunda, P.O.-Khandagiri, Bhubaneswar RFP Ref. No. OGB/RFP/ITD/HARDWARE/002/2018-19, Amendment_1 Date: 04-05-2018 AMENDMENT_1: REQUEST
More informationPremium Online Series
Premium Online Series UPS backup power systems backup protection with double conversion that isolates and conditions output power for clean, consistent, reliable power features: Permanent connection to
More informationSmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System
SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System MODEL NUMBER: SVX120KL Highlights 120kVA / 120kW modular, scalable, 3-phase, Large-Frame tower
More informationshould be able to scale to additional pair controllers with 128 GB Cache across Controllers." replacement. With memory of >= 64 GB
Existing Storage Technical Specification for 100TB To Be Read AS Item Specification Comments Controllers Dual Active-Active controllers. The system Please read the Specifications as " Dual Active-Active
More informationSmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch
SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch MODEL NUMBER: SU8000RT4U Description Tripp Lite 8kVA SmartOnline
More informationNLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX
/TENDER ENQUIRY NO :ENQ/17-18/002964/MM25(01) 1 /DATE :17/11/2017 /Page - 1 Details UOM Number Quantity 11.0000 63 071 0016 : Server with Intel Xeon E5 Two Processors. 16GB DDR4 RAM Expandable to 768GB
More informationARL992/ ARL992-B User Reference Manual
ARL992/ ARL992-B User Reference Manual Specifications Model No ARL992 ARL992-B CPU Intel Core i5-7440eq, 2.90GHz Processors Option: Intel Core i7-7820eq, 3.0 GHz Chipset Intel 7th Gen. Core i5 /i7 processors
More informationTENDER NOTIFICATION SUPPLY, INSTALLATION AND COMMISSIONING OF DESKTOP COMPUTERS
TENDER NOTIFICATION SUPPLY, INSTALLATION AND COMMISSIONING OF DESKTOP COMPUTERS Income-tax Department, Bangalore invites tenders from eligible vendors dealing in Desktop computers to supply, install and
More informationSmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules
SmartOnline SVX Series 90kVA 400/230V 50/60Hz Modular Scalable 3-Phase On-Line Double- Conversion Medium-Frame UPS System, 5 Battery Modules MODEL NUMBER: SVX90KM3P5B Highlights 90kVA/90kW Modular, Scalable,
More informationINVITATION FOR QUOTATION. TEQIP-II/2017/CH2G01/Shopping/126
INVITATION FOR QUOTATION TEQIP-II/2017/CH2G01/Shopping/126 03-Mar-2017 Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive quotation for the
More informationOFFICE OF THE PRINCIPAL COLLEGE OF ARTS & CRAFTS PATNA UNIVERSITY, PATNA
NIQ No.: 03/2016-17 OFFICE OF THE PRINCIPAL COLLEGE OF ARTS & CRAFTS PATNA UNIVERSITY, PATNA NOTICE INVITING QUOTATION Date:08/02/2017 Designation of officer inviting quotation Place, Time & Date of receiving
More informationALL PSU Ltd ROTATION+ 6kVA - 10kVA PARALLEL ON LINE DOUBLE CONVERSION
ALL PSU Ltd Unit D6 Laser Quay, Culpeper Close Medway City Estate, Rochester, Kent, ME2 4HU Phone: 01634-725527 Fax: 01634-739111 E-mail: sales@allpsu.co.uk Web: www.allpsu.co.uk ROTATION+ 6kVA - 10kVA
More informationA. Server : Mid-range servers : TWO
INDIAN INSTITUTE OF ENGINEERING SCIENCE & TECHNOLOGY (Formerly Bengal Engineering and Science University, Howrah) P.O. Botanic Garden, Howrah 711 103, INDIA. (Tel: 91-33-2668 4561 Extn. 600) TENDER NOTICE
More informationSmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America
SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Description Tripp Lite's SU40K (40kVA) SmartOnline Modular 3-Phase Intelligent, True On-Line
More informationTechnical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva
GE Critical Power Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS 3 5 6 8 10 kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91
More informationSmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America
SmartOnline 277/480V 3-Phase Wye 80kVA Modular 3-Phase UPS System, On-line Double- Conversion UPS for North America MODEL NUMBER: SU80KTV Highlights 80,000 VA (80kVA) tower UPS with 4 hot-swappable power
More informationUNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata
UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata- 700106 NOTICE INVITING QUOTATION Sealed Quotations are invited from reputed suppliers
More informationSmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial
SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU16000RT4U Description Tripp Lite 16kVA SmartOnline
More informationUPS Emergency Bed Power Unit
UPS Emergency Bed Power Unit Ergonomic Design with extending Carry Handle Wide Input Voltage Range Compatible with Generators Optional LED Light Audible Alarm Functions Full-time Surge Protection Protection
More informationMAJOR VA Power Inverter
MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in
More informationUPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications
INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,
More informationENGINEERING SPECIFICATION SHEET SPEC. Revision History
SPEC. Revision History Revision Change Information Date No. Description Current version 2010/08/01 1 New revision Initial 2011-1-25 2 Fuse is changed T4.0A 2.0 2011-4-1 3 Add AC adapter external dimension
More informationTECHNICAL SPECIFICATIONS DESKTOP COMPUTER FOR DAS
GUJARAT ENERGY TRANSMISSION CORPORATION LTD. SARADAR PATEL VIDYUT BHAVAN, RACE COURSE, BARODA 390 007. TECHNICAL SPECIFICATIONS FOR DESKTOP COMPUTER FOR DAS GETCO/E/TS-DAS COMP.- 04701/R5, Dt: 13.06.2012
More informationSmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU6000RT3UHV 6000VA online 6U rack / tower UPS (3U Power Module + 3U Battery
More informationSmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch
SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch MODEL NUMBER: SU6000RT4UHVG Highlights 6kVA / 6000VA / 5400W on-line
More informationSmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America
SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America MODEL NUMBER: SU40K Highlights 40,000 VA (40kVA) tower UPS with 2 hot-swappable power modules N+1 redundant
More informationSubject: Supply and Installation of Workstation for high performance computing.
NOTICE INVITING TENDER Subject: Supply and Installation of Workstation for high performance computing. Indian Institute of Technology (Indian School of Mines), Dhanbad invites quotations for the following
More informationUninterruptible Power Supplies
Xi Series 1-6kVA True On-Line UPS Features Rack-Mount/Standalone Format Universal Battery Design (Optional 10 year batteries) Dual Mains Input Dual Position Backlit LCD LCD Load Segment Control 2.5kVA
More informationthe Centric 300 An advanced modular UPS up to 1800kVA/kW
the Centric 300 An advanced modular UPS up to 1800kVA/kW 1 Gamatronic, Israel s Leading Power Electronics Company True to the exceptional reputation earned by Israeli technology companies, Gamatronic has
More informationQuickSpecs. HP Tower UPS T750 G2, T1000 G3, T1500 G3 Overview
Overview HP Tower Uninterruptible Power Systems (UPS) provide advanced power protection and secure your computer equipment and your critical data against damage due to inconsistent and fluctuating power.
More informationSmartOnline V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire
SmartOnline 200-240V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire MODEL NUMBER: SU12KRT4UHW Highlights 12kVA / 12,000VA / 10,800 watt on-line
More informationSocomec Netys PR RT U P S TOWER / RACK MOUNT
Socomec Netys PR RT Ideal solution for protecting small servers, networking devices and peripherals. Assures service continuity to critical applications. Designed for professional applications: the sinevawe
More informationINSTRUCTIONS TO BIDDERS
INSTRUCTIONS TO BIDDERS 1. This document set contains the following: a) Terms and conditions of the Tender - Pages 2 & 3 b) Details of the Firm offering this Quote - Page 4 c) Technical Compliance & Quotation
More informationAIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 10kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 8000 Watts / 10 kva,input 400V 3PH / Output 400V 3PH, Interface Port DB-9 RS-232, Smart-Slot,
More informationHigher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile
More informationBID SPECIFICATIONS COMPUTER HARDWARE FOR CHARLESTON R-1 BOARD OF EDUCATION CHARLESTON, MO
BID SPECIFICATIONS ON COMPUTER HARDWARE FOR CHARLESTON R-1 BOARD OF EDUCATION CHARLESTON, MO VENDOR REQUIREMENTS/TERMS OF CONTRACT: 1). TECHNICAL SUPPORT Vendor must provide a toll-free line for technical
More informationEaton 5PX VA Rack-Tower Guide Specification
Eaton 5PX 1000-3000VA Rack-Tower Guide Specification 1.1 Summary This specification shall define the electrical and mechanical characteristics and requirements for a line-interactive, single phase, uninterruptible
More informationARL 945/ ARL945-B User Reference Manual
ARL 945/ ARL945-B User Reference Manual Specifications Model No ARL945 ARL945-B CPU Intel Core 2 Duo T7500, 2.2GHz Processors (Option: Intel Core 2 Duo T9400, 2.53 GHz) Chipset Intel Gm45 Chipset + ICH9M
More informationSmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial
SmartOnline 208 & 120V 5kVA 4.5kW Double- Conversion UPS, 6U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial MODEL NUMBER: SU5000RT4UTF Highlights 5kVA / 5000VA / 4500 watt online double-conversion
More informationModels HP Z VR Backpack G1 Dock
Overview the HP Z VR Backpack G1 Workstation Models HP Z VR Backpack G1 Dock 2LM71AA Compatibility Docking Station HP Z VR Backpack G1 Dock Mobile Workstation HP Z VR Backpack G1 Workstation NOTE 1: The
More informationLiebert. GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications
Liebert GXT3 5kVA-10kVA Compact UPS Systems For High Power Network Rack Applications LIEBERT GXT3 Liebert GXT3, 5kVA-10kVA UPS Systems: Big Protection, Small Package Today s converged networks require
More informationPower Meter PowerMonitor 500
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific
More informationSpecification for temperature sensor calibration setup
1. Item description Automated Temperature calibration setup made of: A. High accuracy temperature bath with internal and external reference probe, multiple sensors insert kits, carry case and other accessories.
More informationENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5
Table of Contents 1 SCOPE...5 2 ELECTRICAL SPECIFICATION...5 2.1 INPUT REQUIREMENT... 5 2.1.1 Input voltage range... 5 2.1.2 Input frequency range... 5 2.1.3 AC inrush current... 5 2.1.4 Input current...
More informationCELSIUS R670 The new uncompromising high-end workstation
Data Sheet The new uncompromising high-end workstation Issue: April 2009 The CELSIUS R series is the dual-processor platform for the mid-range and high-end segment with a great selection of graphics subsystems.
More informationPowerware 9120 UPS. Product Snapshot. Features
Powerware 9120 UPS Features True double conversion online technology give you protection from all nine power problems Simple installation and operation Intuitive LCD screen provides realtime updates of
More informationSymmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output
Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,
More informationPart Number Class Category Title UPC Code Image Download Country of Origin Cost MSRP. Short Description. Long Description. Main Specifications
Part Number Class Category Title UPC Code Image Download Country of Origin Cost MSRP Short Description Long Description Main Specifications Brand Form Factor Unit Dimension (DxWxH) Shipping Dimension (DxWxH)
More informationDistributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
Distributed by Keor T UPS THREE-PHASE UPS from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES T THREE-PHASE UPS T has been designed with advanced technologies and the
More informationSmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)
SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Highlights 80,000 VA (80kVA) 3-phase tower UPS N+1 redundant modular
More informationMekong River Commission
Mekong River Commission P.O. Box 6101, 184 Fa Ngoum Road, Unit 18, Ban Sithane Neua, Sikhottabong District, Vientiane 01000, Lao PDR Telephone: (856-21) 263 263. Facsimile: (856-21) 263 264 No. RFQ17-141
More informationQualifying requirement (QR):
WBSEDCL WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer : Procurement & Contracts Department Vidyut Bhavan (4 th Floor) : Bidhannagar
More informationVCL-TP, Teleprotection Equipment With Trip Counter Display Panel
VCL-TP, Teleprotection Equipment With Trip Counter Display Panel Data Sheet Copyright: Valiant Communications Limited. 2008-2014 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable
More informationGrowel InfoTech Tech. Specification Growel Model No. InfoTech Canon MF /-
Growel InfoTech Tech. Specification Growel Model InfoTech Canon MF3010 9400/- 5 MFP Laser Printer HP LaserJet 22647/- M1536nf MFP/ Canon MF4750 15300/- 6 Laser Printer Canon 2900B 6480/- Canon LBP6018B
More informationSmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch
SmartOnline 208/240 & 120V 20kVA 18kW, Double-Conversion UPS, N+1, 14U, Network Card Slot, USB, DB9, Bypass Switch MODEL NUMBER: SU20KRT-1TF Highlights 20kVA / 20,000VA / 18,000W on-line double-conversion
More informationARL 970/ ARL970-B User Reference Manual
ARL 970/ ARL970-B User Reference Manual Specifications Model No ARL970 ARL970-B CPU Intel Core i5-2510e, 3M Cache, 2.50GHz Processors (Option: Intel Core i7-2710qe, 6M Cache, 2.10 GHz) Chipset Intel QM77
More informationUPS Series. features: uninterruptible power supply. what great systems are built on.
uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation
More informationSmartOnline 208/230V 2.2kVA 1.98kW Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9, ENERGY STAR
SmartOnline 208/230V 2.2kVA 1.98kW Double- Conversion UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9, ENERGY STAR MODEL NUMBER: SUINT2200LCD2U Highlights Zero transfer time suitable for advanced
More informationFeatures. Intel 45nm Atom Processor N270: 1.6 GHz
POC-C197 NEW Features 19" Slim Point-of-Care Terminal with Intel Atom Processor 19" LCD display with 16.7 M colors Intel Atom (ultra low-power) processor Fanless design with low audible noise Isolated
More information1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.
SECTION 26 04 75 - SURGE PROTECTION DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Applicable provisions of the General Conditions, Supplementary General Conditions and Special Conditions shall govern work performed
More informationSmartOnline V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 3kVA 2.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SUINT3000RTXL2U Description 3000VA / 3kVA / 2500 watt on-line, double-conversion
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR VME BUS COMPUTER (FIELD TERMINAL VME BUS PROCESSOR ASSEMBLY) N.J. Specification No. Effective Date:
More informationMASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase
MASTERELITE MULTITEC MRM/MRT MRM 10-20kVA single/single phase or three/single phase MRT 10-30kVA three/three phase The MasterElite MultiTec range uses advanced digital online (VFI) technology to support
More informationSmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial
SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial MODEL NUMBER: SU3000RTXL3UHV Highlights 3000VA / 3kVA / 2400 watt on-line double-conversion
More informationARP 945 User Reference Manual
ARP 945 User Reference Manual Specifications Model No ARP945 ARP945-B CPU Intel Core 2 Duo T7500 (2.2GHz) Processors (Option: T9400, 2.53GHz) Slots Intel Gm45 Chipset + ICH9M Slot 3x PCI-E (x8) full-size
More informationSmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1500XLRT2U Highlights 1.5kVA / 1500VA / 1350W line interactive 2U
More informationNOTICE INVITING TENDER (NIT) SEALED QUOTATIONS FOR SUPPLY, INSTALLATION AND MAINTENANCE OF THREE (3) LAPTOPS at Head Office, Kolkata
Ref: HO/DIT/Laptop-Proc-NIT/111 Date: 08.08.2018 NOTICE INVITING TENDER (NIT) SEALED QUOTATIONS FOR SUPPLY, INSTALLATION AND MAINTENANCE OF THREE (3) LAPTOPS at Head Office, Kolkata Allahabad Bank intends
More informationSmartOnline V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartOnline 100-120V 1kVA 800W On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU1000RTXL2UA Highlights 1000VA / 1kVA / 800 watt on-line double-conversion
More informationHMIBMUSI29D2801 Modular Box PC HMIBM Universal SSD DC Windows 10 2 slots
Characteristics Modular Box PC HMIBM Universal SSD DC Windows 10 2 slots Main Range of product Product or component type Device short name Processor name Chipset type Free slots Video controller type Operating
More informationSmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA)
SmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS (not expandable to 120kVA) MODEL NUMBER: SU80KX Description Tripp Lite's SU80KX (80kVA) SmartOnline Modular 3-Phase
More informationSymmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output
Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output APC Symmetra LX, 6400 Watts / 8000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232,
More information(A premier Public Sector Bank) Information Technology Division Head Office-Mangalore. Corrigendum 1 dated
(A premier Public Sector Bank) Information Technology Division Head Office-Mangalore. Corrigendum 1 dated 14.09.2017 No. 05/2017-18 dated 24.08.2017 for Empanelment, Supply & Installation of All-In-One
More information