LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE

Size: px
Start display at page:

Download "LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE"

Transcription

1 LANmark Snap-In Toolless connector screened, with rear cover CAT7 GG45 INSTALLATION GUIDE LANmark Snap-In Toolless Connector - Screened (with rear cover) CAT7 GG45

2 Document information Document reference Release September 2002 Published by Contact address BRO-009 LANmark Snap-in Rear cover Cat7 GG Nexans Cabling Solutions Alsembergsesteenweg 2, b Buizingen Belgium Phone Fax Website info.ncs@nexans.com Important Notice The information contained in this document has been carefully checked and is assumed to be entirely correct and reliable at the time of publishing. However, Nexans Cabling Solutions reserves the right to make such changes to its products or its documentation as it deems necessary, in order to make improvements. Nexans Cabling Solutions rejects all responsibility for the use made of its products or of its documentation. In this document, no mention is made of rights with respect to trademarks or tradenames which may attach to certain words or signs. The absence of such mention, however, in no way implies that there is no protection Nexans Cabling Solutions Printed in Belgium

3 INSTALLATION GUIDE FOR LANMARK SNAP-IN TOOLLESS CONNECTOR, SCREENED, WITH REAR COVER CAT7 GG45 TABLE OF CONTENTS Installation of the connector...2 Important Remark Installation is to be performed by qualified service personnel Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 1

4 LANmark Snap-In Toolless Connector - screened (STP) cable How to strip an STP cable Installation of Cat 7 products is much more critical than installing Cat 5. The high performances can only be guaranteed if the installation procedures are followed. Special attention must be given to keep the untwist lengths of the pairs as short as possible. STP ± 45 mm ± 60 mm (outlet) ± 120 mm (patch panel) STP cable : Cut off the outer jacket and braid for the shown length. Position the pairs of the cable as follows : Brown Blue Orange Green 13 mm 60 mm Important Remark : Altough marked on the cable holder, you should not use the A-colour coding as a valid option. Only use B-colour coding Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 2

5 Slide the wire organiser onto the 4 pairs at the same time. Respect the colour code on the wire organiser. Do not untwist the pairs. The distance to the inner foil must be as short as possible. The inner foil must go into the wire organiser and attention must be paid that : the foil of the pairs goes properly into the chambers, especially the crossed pair. make sure the foil is not inserted too deep, otherwise it could make contact with the IDC contacts when inserting the wire organiser in the jack. Pull the pairs over the pair splitter respecting the colour code. The brown conductor is at the outer side. The blue, orange and green conductors are all on the inner side. Use a pair of cutters to cut off the overlength of the pairs and bend the remaining wires into the wire organiser. Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 3

6 Use a screwdriver to separate the 4 pairs a little bit from each other to allow easy insertion of the metal cross of the connector between the pairs and to avoid that the foils are damaged during insertion of the connector. Position the wire organiser correctly oriented on the back of the connector. Push manually until you hear a click. Click Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 4

7 Next put the assembly in the new comfort tool (with the N marked) and close it. Let cm braid to give contact with the U-part. The braid must be positioned under the U-part but may not contact the wire organiser to avoid short circuits with the IDC contacts. Rear cover mounting : hinge the first side of the rear cover on the connector. Then, slide the U-part in place to make contact with the foil. Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 5

8 Next, put on the other side and hinge back sides to close the rear cover. Click on the other side to close the rear cover. Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector - Screened (with rear cover) - 6

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector UTP

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector UTP LANmark EVO Series Snap-in Connector UTP INSTALLATION GUIDE LANmark EVO Series Snap-in Connector UTP Document information Release August 2005 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg

More information

DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables. By Scott MacDonald, KD8BDX. Parts list:

DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables. By Scott MacDonald, KD8BDX. Parts list: DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables By Scott MacDonald, KD8BDX needing the flexibility of custom wiring length and being comfortable with terminating

More information

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly. Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

Factory Line Accessories FL PLUG RJ FL CRIMPTOOL

Factory Line Accessories FL PLUG RJ FL CRIMPTOOL Factory Line Accessories FL PLUG RJ... FL CRIMPTOOL. Description FL PLUG RJ connectors and the corresponding FL CRIMPTOOL crimping pliers are available for field terminations of RJ connectors. The shielded

More information

JUN 2016 Rev B

JUN 2016 Rev B Application Specification 4-907 0 JUN 06 Rev B Sigma-Link Quick-Fit Cable Assembly. INTRODUCTION This specification describes the assembly procedure for Sigma-Link Quick-Fit pre-terminated cable bundle.

More information

LANmark-6 10G LANmark-6 A

LANmark-6 10G LANmark-6 A Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction

More information

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001

Qualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001 Qualified Partner Programme QPP Installation Practice Felice Guarna Wetzikon, Why installation quality Product performance must be preserved by an accurate installation Long term warranty requires design

More information

Description and Assembly Instructions

Description and Assembly Instructions Description and Assembly Instructions Modular Industrial Patch Panel Release 01 12/11 Technical Support HAC.Support@Belden.com The naming of copyrighted trademarks in this manual, even when not specially

More information

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions 860509967 Issue 6, May 2014 SYSTIMAX 360 1100GS3 and 1100GS6 Evolve Modular Panel Instructions General The SYSTIMAX 360 1100GS3 (Cat6) and 1100GS6 (Cat6A) Evolve modular panels exceed ISO and TIA Performance

More information

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1

Design Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1 Design Guidelines LANmark-6A Cabling System January 2015 Revision 2.0 Nexans LANmark-6A Design Guidelines Ver 2.0 - January 2015 - Page 1 This document is intended to provide general guidance on LAN cabling

More information

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4

Field-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4 Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent

More information

ExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014

ExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014 ExpressCard 2000 Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure September 22, 2014 Manual Part Number: 99875721-1.01 REGISTERED TO ISO 9001:2008 MagTek I 1710 Apollo Court

More information

Distribution Module Cat 5E Panels

Distribution Module Cat 5E Panels Issue 1, November 2016 Distribution Module Cat 5E Panels General The CommScope distribution module panels are available in a 24- or 48-port, straight or angled configuration. The panels exceed Category

More information

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red. FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color

More information

Field-testing procedure. LANmark-6

Field-testing procedure. LANmark-6 Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel

More information

Rack Installation Guide

Rack Installation Guide Rack Installation Guide This document provides important information about the Toolless Slide Rail and the Toolless Slide Rail Kit with 1U/2U MA. Each slide rail kit package contains the following items:

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network.

CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network. CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network. # Student ID Student Name Grade (10) 1-1 / 10 - Build a Crossover Cable Objective Build a Category 5 or Category 5e

More information

SYSTIMAX 360 PATCHMAX Modular Panel Instructions

SYSTIMAX 360 PATCHMAX Modular Panel Instructions Issue 1, February 2015 SYSTIMAX 360 PATCHMAX Modular Panel Instructions General The SYSTIMAX 360 PATCHMAX modular panel can be used for both EIA-T568A or EIA-T568B wiring applications and is an approved

More information

ADSL Central Splitter Quick Setup Guide

ADSL Central Splitter Quick Setup Guide ADSL Central Splitter Quick Setup Guide MFDSL004 ADSL Central Splitter Quick Set-up Guide Features High quality low pass filter with optimum performance Surge and overload current protection Wall mounting

More information

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE Version 1.0 Date: September, 2013 Copyright 2007 Altai Technologies Limited ALL RIGHTS RESERVED. Altai Technologies Limited Unit 209, 2/F, East Wing, Building

More information

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S LANmark-7A High-Speed COPPER Solution For 40 Gigabit Applications LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster

More information

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10 Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

HP C8000 Workstation Disassembly Procedures

HP C8000 Workstation Disassembly Procedures HP C8000 Workstation Disassembly Procedures 410892-001 November, 2005 Edition 1 PRODUCT END-OF-LIFE DISASSEMBLY INSTRUCTIONS... 2 1.1 Product Identification...2 1.2 Purpose...2 1.3 Removal Items...2 1.4

More information

12382 South Gateway Park Place, 700 Draper, UT

12382 South Gateway Park Place, 700 Draper, UT I N S T A L L A T I O N G U I D E AN-300 Structured Wiring Distribution Panel 12382 South Gateway Park Place, 700 Draper, UT 84020 1.801.617.3100 www.futuresmart.com Description Features The AN-300 Structured

More information

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * *

Upgrade Instructions. P/N Revision A. October Printer Terminal Holder * * Upgrade Instructions P/N 96-08-0 Revision A October 000 480 Printer Terminal Holder P/N 96-08-0 Revision A *96080* Instructions This terminal holder connects the INTERMEC R 600 Series and 700 Series Computers

More information

PreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations.

PreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. Trunk 6 channels/stranded screened single cables S-STP Cat.7, AWG 23 installation cable diameter 22,3 mm

More information

Cat.6/5e UTP Patch Panels with 45 Jack

Cat.6/5e UTP Patch Panels with 45 Jack Cat.6/5e UTP Patch Panels with 45 Jack Index TOOL KITS TOOL WIRING CONNECTORS LAN/DATACOMM INSTRUMENT MISCELLANEOUS POWER TOOLS FIBER OPTICS MAGNIFICATION & Our Cat.6/5e patch panels are used for high

More information

1530R & 1540 All-in-One Pro Data/Phone Tools

1530R & 1540 All-in-One Pro Data/Phone Tools 1530R & 1540 All-in-One Pro Data/Phone Tools Safety release To cut & strip telephone cable: 1. To cut & strip 4- & 6-conductor flat cable, insert the cable into the slot labeled 6 mm. Squeeze the handles

More information

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High

Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical

More information

Nintendo DSi Wi-Fi Antenna Board

Nintendo DSi Wi-Fi Antenna Board Nintendo DSi Wi-Fi Antenna Board Replacement Replace your Nintendo DSi's Wi-Fi antenna. Written By: Andrew Bookholt ifixit CC BY-NC-SA www.ifixit.com Page 1 of 16 INTRODUCTION Use this guide to replace

More information

Model 1100B CHG Terminator. Operating Instructions

Model 1100B CHG Terminator. Operating Instructions Model 1100B CHG Terminator Operating Instructions 1 Contents: 1.0 Safety Information... 3 2.0 General Introduction... 3 3.0 Operation... 4 2.8 2.1 2.7 V 2.2 2.9 2.2 2.10 2.11 2.11 2.3 2.4 2.5 2.5 2.6 2

More information

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2

Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2 1 Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2 Tsubis Part Number: LCD12-0046 Power Down 1. Power down the controller. 2. Power down the complete machine by turning off the rear

More information

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2

More information

With a surface greater than 10 square cm All types including standard alkaline & lithium coin/button style

With a surface greater than 10 square cm All types including standard alkaline & lithium coin/button style Appendix 3 Product End-of-Life Disassembly instructions Product Identification: Marketing Name / Model Description HP Compaq Business Desktop dc5100 Series, HP business desktop PC Small Form Factor version

More information

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second

More information

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)

3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) 3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) Instructions August 2011 3 78-8130-2330-1-C 1.0 General 1.1 The 3M Add-On Terminals 4220P-100, 4220P-200, 4220P-300 and 4220P-400 are designed to expand

More information

SUBCON 15 HD (High-density) D-Subminiature Connectors

SUBCON 15 HD (High-density) D-Subminiature Connectors SUBCON 15 HD (High-density) D-Subminiature Connectors Installation Instructions 1896_en_D SUBCON SUBCON 15 15 HD HD 1 5 6 10 11 15 15-position High-density D-subminiature Plug 5604602 SUBCON SUBCON 15

More information

Single cable kit for the FCB1010

Single cable kit for the FCB1010 Single cable kit for the FCB1010 1. What is it? With this kit, you can turn your FCB1010 into a phantom powered floorboard, which can do 2-way MIDI communication over one single cable. After installing

More information

Category 5e Solutions

Category 5e Solutions Introduction... 5.2 Cable... 5.3 Patch Panels... 5.4 Modules... 5.5 Patch Cords... 5.8 Mutos and Consolidation Points... 5.13 Outlets... 5.14 www.adckrone.com AUS 1800 801 298 NZ 0800 657 663 5.1 Introduction

More information

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12 Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted

More information

Installing a Power over Ethernet injector

Installing a Power over Ethernet injector Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart

More information

LENS REPLACEMENT PROCEDURE

LENS REPLACEMENT PROCEDURE LCD PROJECTOR LENS MODEL LNS-T31A/W31A LENS REPLACEMENT PROCEDURE NOTE; Lens installation is different in cabinet design (Type A and B). Before installation the lens, check cabinet design and proper installation

More information

edrive RAM Battery Alternate Replacement Procedure

edrive RAM Battery Alternate Replacement Procedure edrive RAM Battery Summary This technical note describes the process for replacing the TINI RAM battery with a higher capacity battery. With the edrive turned on, the external battery can be changed without

More information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B. Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable

More information

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole

More information

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement

MacBook Pro 15 Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement MacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 15 INTRODUCTION You can again use ExpressCard accessories

More information

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number:

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number: Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE 53 00 Rev..0 Part Number: 3000939 Modbus Plus devices must be installed as specified in a network layout

More information

Written By: Charlie Mohr

Written By: Charlie Mohr NEC LCD1770NX Capacitor Replacement Replacement of a capacitor on the power supply circuit board. Written By: Charlie Mohr ifixit CC BY-NC-SA www.ifixit.com Page 1 of 14 INTRODUCTION There are many capacitors

More information

Ethernet Test Access Panel (ETAP) User Manual

Ethernet Test Access Panel (ETAP) User Manual Ethernet Test Access Panel (ETAP) User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the

More information

RH-8 Headphone Station. Installation Guide

RH-8 Headphone Station. Installation Guide RH-8 Headphone Station Installation Guide 2 RH-8 Installation Guide Contents Safety Information...4 Introduction...4 What s in the Box... 5 Top view... 6 Base view... 7 Installation...8 Connections...

More information

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications From the beginning on, 10G Ethernet was intended to retain backwards

More information

The EMITEX PRODUCT GUIDE 2018/19

The EMITEX PRODUCT GUIDE 2018/19 The EMITEX PRODUCT GUIDE 2018/19 ABOUT US QUALITY GUARANTEED Emitex was established in 2002, and since then has gone from strength to strength, becoming one of the most recognisable brands in the voice

More information

Toshiba Satellite L305-S5946 Power Jack Replacement

Toshiba Satellite L305-S5946 Power Jack Replacement Toshiba Satellite L305-S5946 Power Jack Replacement Replace the power jack in your Toshiba Satellite L305-S5946. Written By: Michael Erberich ifixit CC BY-NC-SA www.ifixit.com Page 1 of 16 INTRODUCTION

More information

Distribution Module Panel (DM)

Distribution Module Panel (DM) 860584457 Rev F, APR 2018 www.commscope.com Distribution Module Panel (DM) General The CommScope distribution panels (DM) are available in a 24- or 48-port, straight, angled or recessed angled configuration.

More information

ANIxx. Installation Manual.

ANIxx. Installation Manual. ANIxx Installation Manual www.audac.eu Introduction WaveDynamics Dante audio network interface The ANIxx are Dante audio network interfaces for use with WaveDynamics supporting amplifiers, supporting two

More information

Print Mechanism Maintenance Kit

Print Mechanism Maintenance Kit Print Mechanism Maintenance Kit Installation Instructions This kit includes the parts and documentation necessary to install the print mechanism maintenance kit in the following printers: ZT0 ZT0 ZT0 Read

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

PC9/P9 CPU Card Replacement

PC9/P9 CPU Card Replacement Introduction These instructions explain how to replace the CPU card in the PC9 Industrial PC or the P9 PowerStation. They include steps for disassembling the unit, removing the old CPU card, installing

More information

2 PIECE BOARD-TO-BOARD

2 PIECE BOARD-TO-BOARD 2 PIECE BOARD-TO-BOARD 201-01-123 1. SPECIFICATION DISTRIBUTION No restrictions for issue 2. SCOPE This specification contains the application notes for the 9159 two part connectors. 3. PRODUCTS 10-9159

More information

IBDN 110 Cross-Connect System

IBDN 110 Cross-Connect System IBDN 110 Cross-Connect System Connecting & Wiring Blocks Cross-Connect Kits Wall Mount Frame Kits Patch Cords Labels & Management Accessories For For A Complete End-to-End 110 Solution what s coming next.

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06 Contents Cat6 Structured Cabling Solutions U/UTP Cabling Solutions Structured Cabling Solutions LAN Cables... 03 Patch Cords... 04 Connectors... 05 Patch Panels... 06 U/FTP Cabling Solutions LAN Cables...

More information

A-100G6 - Basic frame assembly diagram

A-100G6 - Basic frame assembly diagram doepfer System A - 100 Rack system A-100 G A-100G6 - Basic frame assembly diagram Parts: 1 Rail with lip, and with tapped hole strip inserted (with M3 threads). 2 Rail with lip, with three M3 hexagon nuts

More information

Clarity 6 and 5e. Clarity 6 and Clarity 5E Modular to 110 Patch Panels. Clarity 6 and Clarity 5E Modular to 110 Mini Patch Panels

Clarity 6 and 5e. Clarity 6 and Clarity 5E Modular to 110 Patch Panels. Clarity 6 and Clarity 5E Modular to 110 Mini Patch Panels clarity patch panels Clarity 6 and 5e Clarity patch panels combine the Ortronics commitment to ease and reliability with the ETL verified TIA-568C.2 Category 6 or Category 5e performance of center tuned

More information

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions

A0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions A0319 Bluetooth Wall-Dock for Distributed Audio Intelligent Entertainment Infrastructure Security Solutions The A0319 is an on-wall bluetooth docking station that will charge an ipod, iphone or itouch

More information

USB Controlled DMX interface

USB Controlled DMX interface USB Controlled DMX interface Control DMX fixtures using a PC and USB interface. Stand-alone test function that outputs all 512 channels at a time, with adjustable levels. Total solder points: 117 Difficulty

More information

Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017

Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017 Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017 Please read these instructions before purchasing the MIDI interface, to make sure you are comfortable performing the necessary steps.

More information

BuffaloLabs WiFi Lantern Assembly guide version 1

BuffaloLabs WiFi Lantern Assembly guide version 1 BuffaloLabs WiFi Lantern Assembly guide version 1 Needed equipment: Solder iron Solder wire Cutter Wire stripper (optional) Hot glue gun Overview of the components (not including USB cable and box panels)

More information

BENSON VARIANTE² TUBULAR HEATER NEW FAN CONTROL/LIMIT STAT RETROFIT NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

BENSON VARIANTE² TUBULAR HEATER NEW FAN CONTROL/LIMIT STAT RETROFIT NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) Technical Bulletin BENSON VARIANTE² TUBULAR HEATER NEW FAN CONTROL/LIMIT STAT RETROFIT NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) WARNINGS Benson equipment must be installed and maintained in accordance

More information

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector

M12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45

More information

Termination for 568A and 568B pin configurations.

Termination for 568A and 568B pin configurations. 1 Termination for 568A and 568B pin configurations. The four twisted pairs in Unshielded Twisted Pair (UTP) cabling terminate in eight-pin modular jacks. There are two different pin configurations permitted

More information

MacBook Pro 15" Core Duo Model A1150 ExpressCard Cage Replacement

MacBook Pro 15 Core Duo Model A1150 ExpressCard Cage Replacement MacBook Pro 15" Core Duo Model A1150 ExpressCard Cage Replacement Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 17 INTRODUCTION You can again use ExpressCard accessories by replacing a

More information

SMA Series - Crimp Plug and Jack

SMA Series - Crimp Plug and Jack Plug Features: SMA connectors are semi-precision, subminiature devices that provide repeatable electrical performance. These devices offer broadband performance with low reflection. These properties, along

More information

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.

Better all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded. Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector

More information

REMOTE HEAD ADAPTER INSTALLATION GUIDE

REMOTE HEAD ADAPTER INSTALLATION GUIDE REMOTE HEAD ADAPTER INSTALLATION GUIDE The Remote Head adapter is a valuable accessory for the Uniden BC-780, 785 and 796 scanners. It allows the scanner's control panel to be removed from the radio and

More information

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster

More information

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE

T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE INDEX 1. Interfaces and Controls...1 2. Power On...2 3. Setup...2 3.1 To set the UNIT...3 3.2 To set the LAN Length Adjustment...3 3.3 To set the COAX Length

More information

MacBook Core 2 Duo Clutch Cover

MacBook Core 2 Duo Clutch Cover MacBook Core 2 Duo Clutch Cover Replacement Replace the clutch cover on your MacBook Core 2 Duo. Written By: Ben Eisenman ifixit CC BY-NC-SA www.ifixit.com Page 1 of 29 INTRODUCTION Replace the curved

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

Replacement Keyswitch Assembly

Replacement Keyswitch Assembly Installation Instructions Replacement Keyswitch Assembly (Catalog No. 2711E-NKSW1) Applicable Terminals Use this replacement keyswitch with PanelView Terminals 2711-KA1, -KC1, -TA1, -TC1, -TA4, -TC4 and

More information

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013

MCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013 1. Table of Contents 1. Table of Contents Page 1 2. Remove Failed MCH-103.2 Page 1 3. Install MCH-103.2 to MCH-102NW Page 2 4. Install NC3FX-HD to MCH-103.2 Page 3 5. Install MCH-103.2 Battery Terminal

More information

CMA Installation Guide

CMA Installation Guide MA Installation Guide This document provides installation instructions for the following cable management arm (MA) kits: 1U/2U MA Upgrade Kit for Toolless Slide Rail One MA (form factor: 1U or 2U) One

More information

Modular plugs, accessories and tooling

Modular plugs, accessories and tooling Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for

More information

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311

More information

PATCH PANEL Easy Patch INSTRUCTION MANUAL

PATCH PANEL Easy Patch INSTRUCTION MANUAL Page 1 BDA90-1 PATCH PANEL Easy Patch 96 Bantam (TT) Jacks EDAC 56-pin termination NPPA-TT-E56 INSTUCTION MANUAL Easy Patch NPPA-TT-E56 INSTUCTION MANUAL Page 2 BDA90-1 Index 1. Electrical configuration...

More information

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second is the newest, fastest-growing data rate

More information

Engraved Labelling Service

Engraved Labelling Service Engraved Labelling Service Laser precision Wide range of pre-designed templates Choice of adhesive, non-adhesive or magnetic backing Choice of 15 label colours Design your own label Description Size Label

More information

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

INFORMATION AND COMMUNICATION TECHNOLOGY

INFORMATION AND COMMUNICATION TECHNOLOGY Draft KEMENTERIAN PELAJARAN MALAYSIA INFORMATION AND COMMUNICATION TECHNOLOGY LEARNING MODULE COMPUTER NETWORKS AND COMMUNICATIONS SETTING NETWORK FACILITIES MODULE Pusat Perkembangan Kurikulum Kementerian

More information

MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation

MacBook Pro 15 Core 2 Duo Models A1226 and A1260 SSD Installation MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation Written By: Dozuki System 2017 guides.crucial.com Page 1 of 10 INTRODUCTION You can install hard drives up to 9.5mm thick. Some drive

More information

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017 2,5 and 5GBASE-T A Study of Development and Deployment White Paper January 2017 For more than fifteen years, Category 5e cabling has provided a robust channel for 100BASE-TX and 1000BASE-T to operate.

More information

MacBook Core 2 Duo Optical Drive

MacBook Core 2 Duo Optical Drive MacBook Core 2 Duo Optical Drive Replacement Written By: Dozuki System 2017 guides.crucial.com Page 1 of 17 INTRODUCTION Upgrade or replace the combo or SuperDrive (requires a slim drive). TOOLS: Coin

More information

imac Intel 27" EMC 2639 Hard Drive

imac Intel 27 EMC 2639 Hard Drive imac Intel 27" EMC 2639 Hard Drive Replacement Replace the Hard Drive in your imac Intel 27" EMC 2639. Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 26 INTRODUCTION Replacing the

More information

Parts and Accessories Installation Instructions

Parts and Accessories Installation Instructions Parts and Accessories Installation Instructions TV function retrofit kit BMW 7 Series (E 65 and E 66) These installation instructions are only valid for cars with SA 69 (navigation system) Important information

More information

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board Installation Instructions PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should

More information