LANmark Snap-In Toolless connector. screened, with rear cover CAT7 GG45 INSTALLATION GUIDE
|
|
- Doris Lloyd
- 5 years ago
- Views:
Transcription
1 LANmark Snap-In Toolless connector screened, with rear cover CAT7 GG45 INSTALLATION GUIDE LANmark Snap-In Toolless Connector - Screened (with rear cover) CAT7 GG45
2 Document information Document reference Release September 2002 Published by Contact address BRO-009 LANmark Snap-in Rear cover Cat7 GG Nexans Cabling Solutions Alsembergsesteenweg 2, b Buizingen Belgium Phone Fax Website info.ncs@nexans.com Important Notice The information contained in this document has been carefully checked and is assumed to be entirely correct and reliable at the time of publishing. However, Nexans Cabling Solutions reserves the right to make such changes to its products or its documentation as it deems necessary, in order to make improvements. Nexans Cabling Solutions rejects all responsibility for the use made of its products or of its documentation. In this document, no mention is made of rights with respect to trademarks or tradenames which may attach to certain words or signs. The absence of such mention, however, in no way implies that there is no protection Nexans Cabling Solutions Printed in Belgium
3 INSTALLATION GUIDE FOR LANMARK SNAP-IN TOOLLESS CONNECTOR, SCREENED, WITH REAR COVER CAT7 GG45 TABLE OF CONTENTS Installation of the connector...2 Important Remark Installation is to be performed by qualified service personnel Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 1
4 LANmark Snap-In Toolless Connector - screened (STP) cable How to strip an STP cable Installation of Cat 7 products is much more critical than installing Cat 5. The high performances can only be guaranteed if the installation procedures are followed. Special attention must be given to keep the untwist lengths of the pairs as short as possible. STP ± 45 mm ± 60 mm (outlet) ± 120 mm (patch panel) STP cable : Cut off the outer jacket and braid for the shown length. Position the pairs of the cable as follows : Brown Blue Orange Green 13 mm 60 mm Important Remark : Altough marked on the cable holder, you should not use the A-colour coding as a valid option. Only use B-colour coding Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 2
5 Slide the wire organiser onto the 4 pairs at the same time. Respect the colour code on the wire organiser. Do not untwist the pairs. The distance to the inner foil must be as short as possible. The inner foil must go into the wire organiser and attention must be paid that : the foil of the pairs goes properly into the chambers, especially the crossed pair. make sure the foil is not inserted too deep, otherwise it could make contact with the IDC contacts when inserting the wire organiser in the jack. Pull the pairs over the pair splitter respecting the colour code. The brown conductor is at the outer side. The blue, orange and green conductors are all on the inner side. Use a pair of cutters to cut off the overlength of the pairs and bend the remaining wires into the wire organiser. Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 3
6 Use a screwdriver to separate the 4 pairs a little bit from each other to allow easy insertion of the metal cross of the connector between the pairs and to avoid that the foils are damaged during insertion of the connector. Position the wire organiser correctly oriented on the back of the connector. Push manually until you hear a click. Click Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 4
7 Next put the assembly in the new comfort tool (with the N marked) and close it. Let cm braid to give contact with the U-part. The braid must be positioned under the U-part but may not contact the wire organiser to avoid short circuits with the IDC contacts. Rear cover mounting : hinge the first side of the rear cover on the connector. Then, slide the U-part in place to make contact with the foil. Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector- Cat7 - Screened (with rear cover) - 5
8 Next, put on the other side and hinge back sides to close the rear cover. Click on the other side to close the rear cover. Nexans Cabling Solutions Installation Guide LANmark Snap-In Toolless Connector - Screened (with rear cover) - 6
INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector UTP
LANmark EVO Series Snap-in Connector UTP INSTALLATION GUIDE LANmark EVO Series Snap-in Connector UTP Document information Release August 2005 Published by Contact address Nexans Cabling Solutions Alsembergsesteenweg
More informationDXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables. By Scott MacDonald, KD8BDX. Parts list:
DXE Technical Note: Importance of Correct Termination of Shielded Cat5 Networking Cables By Scott MacDonald, KD8BDX needing the flexibility of custom wiring length and being comfortable with terminating
More informationCONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.
Revised Sept-28-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Instructions CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Kit
More informationOMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE
OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.
More informationFactory Line Accessories FL PLUG RJ FL CRIMPTOOL
Factory Line Accessories FL PLUG RJ... FL CRIMPTOOL. Description FL PLUG RJ connectors and the corresponding FL CRIMPTOOL crimping pliers are available for field terminations of RJ connectors. The shielded
More informationJUN 2016 Rev B
Application Specification 4-907 0 JUN 06 Rev B Sigma-Link Quick-Fit Cable Assembly. INTRODUCTION This specification describes the assembly procedure for Sigma-Link Quick-Fit pre-terminated cable bundle.
More informationLANmark-6 10G LANmark-6 A
Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction
More informationQualified Partner Programme QPP. Installation Practice Felice Guarna Wetzikon, July 2001
Qualified Partner Programme QPP Installation Practice Felice Guarna Wetzikon, Why installation quality Product performance must be preserved by an accurate installation Long term warranty requires design
More informationDescription and Assembly Instructions
Description and Assembly Instructions Modular Industrial Patch Panel Release 01 12/11 Technical Support HAC.Support@Belden.com The naming of copyrighted trademarks in this manual, even when not specially
More informationSYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions
860509967 Issue 6, May 2014 SYSTIMAX 360 1100GS3 and 1100GS6 Evolve Modular Panel Instructions General The SYSTIMAX 360 1100GS3 (Cat6) and 1100GS6 (Cat6A) Evolve modular panels exceed ISO and TIA Performance
More informationDesign Guidelines. LANmark-6A Cabling System. January 2015 Revision 2.0. Nexans LANmark-6A Design Guidelines Ver January Page 1
Design Guidelines LANmark-6A Cabling System January 2015 Revision 2.0 Nexans LANmark-6A Design Guidelines Ver 2.0 - January 2015 - Page 1 This document is intended to provide general guidance on LAN cabling
More informationField-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4
Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent
More informationExpressCard Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure. September 22, 2014
ExpressCard 2000 Instant Issuance Card Personalization System Ethernet Jack Replacement Procedure September 22, 2014 Manual Part Number: 99875721-1.01 REGISTERED TO ISO 9001:2008 MagTek I 1710 Apollo Court
More informationDistribution Module Cat 5E Panels
Issue 1, November 2016 Distribution Module Cat 5E Panels General The CommScope distribution module panels are available in a 24- or 48-port, straight or angled configuration. The panels exceed Category
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationField-testing procedure. LANmark-6
Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel
More informationRack Installation Guide
Rack Installation Guide This document provides important information about the Toolless Slide Rail and the Toolless Slide Rail Kit with 1U/2U MA. Each slide rail kit package contains the following items:
More informationPhase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:
Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss
More informationCNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network.
CNE301 Network I Lab 04 Building a cross-over cable and configuring back2back network. # Student ID Student Name Grade (10) 1-1 / 10 - Build a Crossover Cable Objective Build a Category 5 or Category 5e
More informationSYSTIMAX 360 PATCHMAX Modular Panel Instructions
Issue 1, February 2015 SYSTIMAX 360 PATCHMAX Modular Panel Instructions General The SYSTIMAX 360 PATCHMAX modular panel can be used for both EIA-T568A or EIA-T568B wiring applications and is an approved
More informationADSL Central Splitter Quick Setup Guide
ADSL Central Splitter Quick Setup Guide MFDSL004 ADSL Central Splitter Quick Set-up Guide Features High quality low pass filter with optimum performance Surge and overload current protection Wall mounting
More informationALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved
ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE Version 1.0 Date: September, 2013 Copyright 2007 Altai Technologies Limited ALL RIGHTS RESERVED. Altai Technologies Limited Unit 209, 2/F, East Wing, Building
More informationLANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S
LANmark-7A High-Speed COPPER Solution For 40 Gigabit Applications LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables 0 Cable Spools Unshielded
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationHP C8000 Workstation Disassembly Procedures
HP C8000 Workstation Disassembly Procedures 410892-001 November, 2005 Edition 1 PRODUCT END-OF-LIFE DISASSEMBLY INSTRUCTIONS... 2 1.1 Product Identification...2 1.2 Purpose...2 1.3 Removal Items...2 1.4
More information12382 South Gateway Park Place, 700 Draper, UT
I N S T A L L A T I O N G U I D E AN-300 Structured Wiring Distribution Panel 12382 South Gateway Park Place, 700 Draper, UT 84020 1.801.617.3100 www.futuresmart.com Description Features The AN-300 Structured
More informationUpgrade Instructions. P/N Revision A. October Printer Terminal Holder * *
Upgrade Instructions P/N 96-08-0 Revision A October 000 480 Printer Terminal Holder P/N 96-08-0 Revision A *96080* Instructions This terminal holder connects the INTERMEC R 600 Series and 700 Series Computers
More informationPreCONNECT COPPER are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations.
are factory assembled copper data cable Trunks and Multijumper for Plug-and-Play installations. Trunk 6 channels/stranded screened single cables S-STP Cat.7, AWG 23 installation cable diameter 22,3 mm
More informationCat.6/5e UTP Patch Panels with 45 Jack
Cat.6/5e UTP Patch Panels with 45 Jack Index TOOL KITS TOOL WIRING CONNECTORS LAN/DATACOMM INSTRUMENT MISCELLANEOUS POWER TOOLS FIBER OPTICS MAGNIFICATION & Our Cat.6/5e patch panels are used for high
More information1530R & 1540 All-in-One Pro Data/Phone Tools
1530R & 1540 All-in-One Pro Data/Phone Tools Safety release To cut & strip telephone cable: 1. To cut & strip 4- & 6-conductor flat cable, insert the cable into the slot labeled 6 mm. Squeeze the handles
More informationOperating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and gold plated contacts available High
Operating voltages up to 40 kvdc Operating current up to 30 Amps Advanced contact technology Silver plated and contacts available High performance insulation material General characteristics and technical
More informationNintendo DSi Wi-Fi Antenna Board
Nintendo DSi Wi-Fi Antenna Board Replacement Replace your Nintendo DSi's Wi-Fi antenna. Written By: Andrew Bookholt ifixit CC BY-NC-SA www.ifixit.com Page 1 of 16 INTRODUCTION Use this guide to replace
More informationModel 1100B CHG Terminator. Operating Instructions
Model 1100B CHG Terminator Operating Instructions 1 Contents: 1.0 Safety Information... 3 2.0 General Introduction... 3 3.0 Operation... 4 2.8 2.1 2.7 V 2.2 2.9 2.2 2.10 2.11 2.11 2.3 2.4 2.5 2.5 2.6 2
More informationInstallation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2
1 Installation Guide for Mazak Mazatrol M - Plus, M-2, M32, T-Plus, T2 Tsubis Part Number: LCD12-0046 Power Down 1. Power down the controller. 2. Power down the complete machine by turning off the rear
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationWith a surface greater than 10 square cm All types including standard alkaline & lithium coin/button style
Appendix 3 Product End-of-Life Disassembly instructions Product Identification: Marketing Name / Model Description HP Compaq Business Desktop dc5100 Series, HP business desktop PC Small Form Factor version
More informationLANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S
LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second
More information3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)
3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) Instructions August 2011 3 78-8130-2330-1-C 1.0 General 1.1 The 3M Add-On Terminals 4220P-100, 4220P-200, 4220P-300 and 4220P-400 are designed to expand
More informationSUBCON 15 HD (High-density) D-Subminiature Connectors
SUBCON 15 HD (High-density) D-Subminiature Connectors Installation Instructions 1896_en_D SUBCON SUBCON 15 15 HD HD 1 5 6 10 11 15 15-position High-density D-subminiature Plug 5604602 SUBCON SUBCON 15
More informationSingle cable kit for the FCB1010
Single cable kit for the FCB1010 1. What is it? With this kit, you can turn your FCB1010 into a phantom powered floorboard, which can do 2-way MIDI communication over one single cable. After installing
More informationCategory 5e Solutions
Introduction... 5.2 Cable... 5.3 Patch Panels... 5.4 Modules... 5.5 Patch Cords... 5.8 Mutos and Consolidation Points... 5.13 Outlets... 5.14 www.adckrone.com AUS 1800 801 298 NZ 0800 657 663 5.1 Introduction
More informationEthernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 12
Technical Data Ethernet Media Bulletin Numbers 585, 585A, 585BP, 585BT, 585BX, 585BZ, 585D, 585J Topic Page Cable Spools Cordsets & Patchcords 5 Patchcords & Field Attachables Cable Spools Unshielded Twisted
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationLENS REPLACEMENT PROCEDURE
LCD PROJECTOR LENS MODEL LNS-T31A/W31A LENS REPLACEMENT PROCEDURE NOTE; Lens installation is different in cabinet design (Type A and B). Before installation the lens, check cabinet design and proper installation
More informationedrive RAM Battery Alternate Replacement Procedure
edrive RAM Battery Summary This technical note describes the process for replacing the TINI RAM battery with a higher capacity battery. With the edrive turned on, the external battery can be changed without
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More informationNavigator II INstallatIoN MaNUal For static and PaN/tIlt configurations
Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole
More informationMacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement
MacBook Pro 15" Core 2 Duo Models A1226 and A1260 ExpressCard Cage Replacement Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 15 INTRODUCTION You can again use ExpressCard accessories
More informationSchneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE Rev. 1.0 Part Number:
Schneider Automation Modbus Plus Network Installing Clustered Node Devices Publication: 890 USE 53 00 Rev..0 Part Number: 3000939 Modbus Plus devices must be installed as specified in a network layout
More informationWritten By: Charlie Mohr
NEC LCD1770NX Capacitor Replacement Replacement of a capacitor on the power supply circuit board. Written By: Charlie Mohr ifixit CC BY-NC-SA www.ifixit.com Page 1 of 14 INTRODUCTION There are many capacitors
More informationEthernet Test Access Panel (ETAP) User Manual
Ethernet Test Access Panel (ETAP) User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the
More informationRH-8 Headphone Station. Installation Guide
RH-8 Headphone Station Installation Guide 2 RH-8 Installation Guide Contents Safety Information...4 Introduction...4 What s in the Box... 5 Top view... 6 Base view... 7 Installation...8 Connections...
More informationLANmark-6A. High-speed Copper Solution For 10 Gigabit Applications
LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications From the beginning on, 10G Ethernet was intended to retain backwards
More informationThe EMITEX PRODUCT GUIDE 2018/19
The EMITEX PRODUCT GUIDE 2018/19 ABOUT US QUALITY GUARANTEED Emitex was established in 2002, and since then has gone from strength to strength, becoming one of the most recognisable brands in the voice
More informationToshiba Satellite L305-S5946 Power Jack Replacement
Toshiba Satellite L305-S5946 Power Jack Replacement Replace the power jack in your Toshiba Satellite L305-S5946. Written By: Michael Erberich ifixit CC BY-NC-SA www.ifixit.com Page 1 of 16 INTRODUCTION
More informationDistribution Module Panel (DM)
860584457 Rev F, APR 2018 www.commscope.com Distribution Module Panel (DM) General The CommScope distribution panels (DM) are available in a 24- or 48-port, straight, angled or recessed angled configuration.
More informationANIxx. Installation Manual.
ANIxx Installation Manual www.audac.eu Introduction WaveDynamics Dante audio network interface The ANIxx are Dante audio network interfaces for use with WaveDynamics supporting amplifiers, supporting two
More informationPrint Mechanism Maintenance Kit
Print Mechanism Maintenance Kit Installation Instructions This kit includes the parts and documentation necessary to install the print mechanism maintenance kit in the following printers: ZT0 ZT0 ZT0 Read
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationPC9/P9 CPU Card Replacement
Introduction These instructions explain how to replace the CPU card in the PC9 Industrial PC or the P9 PowerStation. They include steps for disassembling the unit, removing the old CPU card, installing
More information2 PIECE BOARD-TO-BOARD
2 PIECE BOARD-TO-BOARD 201-01-123 1. SPECIFICATION DISTRIBUTION No restrictions for issue 2. SCOPE This specification contains the application notes for the 9159 two part connectors. 3. PRODUCTS 10-9159
More informationIBDN 110 Cross-Connect System
IBDN 110 Cross-Connect System Connecting & Wiring Blocks Cross-Connect Kits Wall Mount Frame Kits Patch Cords Labels & Management Accessories For For A Complete End-to-End 110 Solution what s coming next.
More informationProduct Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)
Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:
More informationContents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06
Contents Cat6 Structured Cabling Solutions U/UTP Cabling Solutions Structured Cabling Solutions LAN Cables... 03 Patch Cords... 04 Connectors... 05 Patch Panels... 06 U/FTP Cabling Solutions LAN Cables...
More informationA-100G6 - Basic frame assembly diagram
doepfer System A - 100 Rack system A-100 G A-100G6 - Basic frame assembly diagram Parts: 1 Rail with lip, and with tapped hole strip inserted (with M3 threads). 2 Rail with lip, with three M3 hexagon nuts
More informationClarity 6 and 5e. Clarity 6 and Clarity 5E Modular to 110 Patch Panels. Clarity 6 and Clarity 5E Modular to 110 Mini Patch Panels
clarity patch panels Clarity 6 and 5e Clarity patch panels combine the Ortronics commitment to ease and reliability with the ETL verified TIA-568C.2 Category 6 or Category 5e performance of center tuned
More informationA0319. Bluetooth Wall-Dock for Distributed Audio. Intelligent Entertainment Infrastructure Security Solutions
A0319 Bluetooth Wall-Dock for Distributed Audio Intelligent Entertainment Infrastructure Security Solutions The A0319 is an on-wall bluetooth docking station that will charge an ipod, iphone or itouch
More informationUSB Controlled DMX interface
USB Controlled DMX interface Control DMX fixtures using a PC and USB interface. Stand-alone test function that outputs all 512 channels at a time, with adjustable levels. Total solder points: 117 Difficulty
More informationInstalling PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017
Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017 Please read these instructions before purchasing the MIDI interface, to make sure you are comfortable performing the necessary steps.
More informationBuffaloLabs WiFi Lantern Assembly guide version 1
BuffaloLabs WiFi Lantern Assembly guide version 1 Needed equipment: Solder iron Solder wire Cutter Wire stripper (optional) Hot glue gun Overview of the components (not including USB cable and box panels)
More informationBENSON VARIANTE² TUBULAR HEATER NEW FAN CONTROL/LIMIT STAT RETROFIT NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)
Technical Bulletin BENSON VARIANTE² TUBULAR HEATER NEW FAN CONTROL/LIMIT STAT RETROFIT NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P) WARNINGS Benson equipment must be installed and maintained in accordance
More informationM12 connector D-coding M12 connector X-coding RJ45 IP20 connector PushPull RJ45 IP65 / IP67 connector
M12 connectors Directory Chapter Page General information....02 M12 connector D-coding....06 M12 connector X-coding....20 RJ45 IP20 connector....27 PushPull RJ45 IP65 / IP67 connector....46 Han 3 A RJ45
More informationTermination for 568A and 568B pin configurations.
1 Termination for 568A and 568B pin configurations. The four twisted pairs in Unshielded Twisted Pair (UTP) cabling terminate in eight-pin modular jacks. There are two different pin configurations permitted
More informationMacBook Pro 15" Core Duo Model A1150 ExpressCard Cage Replacement
MacBook Pro 15" Core Duo Model A1150 ExpressCard Cage Replacement Written By: irobot ifixit CC BY-NC-SA www.ifixit.com Page 1 of 17 INTRODUCTION You can again use ExpressCard accessories by replacing a
More informationSMA Series - Crimp Plug and Jack
Plug Features: SMA connectors are semi-precision, subminiature devices that provide repeatable electrical performance. These devices offer broadband performance with low reflection. These properties, along
More informationBetter all-round. DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications. PoE+ 10 GBE. coded.
Better all-round. X coded D coded 10 GBE PoE+ DataVoice Circular connectors STX M12x1 IP67 Connector series for industrial applications STX M12x1 IP67 connector series With the STX M12x1 IP67 connector
More informationREMOTE HEAD ADAPTER INSTALLATION GUIDE
REMOTE HEAD ADAPTER INSTALLATION GUIDE The Remote Head adapter is a valuable accessory for the Uniden BC-780, 785 and 796 scanners. It allows the scanner's control panel to be removed from the radio and
More informationLANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS
LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster
More informationT0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE
T0046 PROFESSIONAL LAN CABLE TESTER USER GUIDE INDEX 1. Interfaces and Controls...1 2. Power On...2 3. Setup...2 3.1 To set the UNIT...3 3.2 To set the LAN Length Adjustment...3 3.3 To set the COAX Length
More informationMacBook Core 2 Duo Clutch Cover
MacBook Core 2 Duo Clutch Cover Replacement Replace the clutch cover on your MacBook Core 2 Duo. Written By: Ben Eisenman ifixit CC BY-NC-SA www.ifixit.com Page 1 of 29 INTRODUCTION Replace the curved
More informationPower Supply and Fan Module Installation
3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page
More informationReplacement Keyswitch Assembly
Installation Instructions Replacement Keyswitch Assembly (Catalog No. 2711E-NKSW1) Applicable Terminals Use this replacement keyswitch with PanelView Terminals 2711-KA1, -KC1, -TA1, -TC1, -TA4, -TC4 and
More informationMCH WIRE HARNESS WITH QUICK DISCONNECT REPLACEMENT Initial Release 1/31/2013
1. Table of Contents 1. Table of Contents Page 1 2. Remove Failed MCH-103.2 Page 1 3. Install MCH-103.2 to MCH-102NW Page 2 4. Install NC3FX-HD to MCH-103.2 Page 3 5. Install MCH-103.2 Battery Terminal
More informationCMA Installation Guide
MA Installation Guide This document provides installation instructions for the following cable management arm (MA) kits: 1U/2U MA Upgrade Kit for Toolless Slide Rail One MA (form factor: 1U or 2U) One
More informationModular plugs, accessories and tooling
Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for
More informationUSBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version
USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311
More informationPATCH PANEL Easy Patch INSTRUCTION MANUAL
Page 1 BDA90-1 PATCH PANEL Easy Patch 96 Bantam (TT) Jacks EDAC 56-pin termination NPPA-TT-E56 INSTUCTION MANUAL Easy Patch NPPA-TT-E56 INSTUCTION MANUAL Page 2 BDA90-1 Index 1. Electrical configuration...
More informationLANmark-6A. High-speed Copper Solution For 10 Gigabit Applications
LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second is the newest, fastest-growing data rate
More informationEngraved Labelling Service
Engraved Labelling Service Laser precision Wide range of pre-designed templates Choice of adhesive, non-adhesive or magnetic backing Choice of 15 label colours Design your own label Description Size Label
More informationPanduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA
Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationINFORMATION AND COMMUNICATION TECHNOLOGY
Draft KEMENTERIAN PELAJARAN MALAYSIA INFORMATION AND COMMUNICATION TECHNOLOGY LEARNING MODULE COMPUTER NETWORKS AND COMMUNICATIONS SETTING NETWORK FACILITIES MODULE Pusat Perkembangan Kurikulum Kementerian
More informationMacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation
MacBook Pro 15" Core 2 Duo Models A1226 and A1260 SSD Installation Written By: Dozuki System 2017 guides.crucial.com Page 1 of 10 INTRODUCTION You can install hard drives up to 9.5mm thick. Some drive
More information2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017
2,5 and 5GBASE-T A Study of Development and Deployment White Paper January 2017 For more than fifteen years, Category 5e cabling has provided a robust channel for 100BASE-TX and 1000BASE-T to operate.
More informationMacBook Core 2 Duo Optical Drive
MacBook Core 2 Duo Optical Drive Replacement Written By: Dozuki System 2017 guides.crucial.com Page 1 of 17 INTRODUCTION Upgrade or replace the combo or SuperDrive (requires a slim drive). TOOLS: Coin
More informationimac Intel 27" EMC 2639 Hard Drive
imac Intel 27" EMC 2639 Hard Drive Replacement Replace the Hard Drive in your imac Intel 27" EMC 2639. Written By: Walter Galan ifixit CC BY-NC-SA www.ifixit.com Page 1 of 26 INTRODUCTION Replacing the
More informationParts and Accessories Installation Instructions
Parts and Accessories Installation Instructions TV function retrofit kit BMW 7 Series (E 65 and E 66) These installation instructions are only valid for cars with SA 69 (navigation system) Important information
More informationPowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board
Installation Instructions PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board!!! ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should
More information