7415 x. Made in Germany. fluid sensors and diagnostic systems. position sensors and object recognition bus, identification and control systems
|
|
- Randolph Richardson
- 5 years ago
- Views:
Transcription
1 7 x Made in Germany 00 fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems
2 Easy adjustment and parameter setting. Clear CD display with simple pushbutton setup. Primary voltage V dc or 0 / 0V ac. Switching and transistor outputs. Analogue also available. Standstill, overspeed, direction, slip and frequency conversion. Although PC applications in industrial automation are becoming more and more versatile there are still numerous processes in practice which require decentralised monitoring. For this ifm electronic offers a number of pulse evaluation systems in the product group ecomat 00. The application area s from simple standstill monitoring or blockage protection of a conveyor belt, maximum speed monitoring in wind power stations, slip monitoring of couplings through to direction monitoring, e.g. twin pumps with non-return valves. Different units for rail mounting and compact designs in M8 and M0 metal housings are available. They include microprocessor-controlled units for pane mounting to display ue signals, RPM, speeds, processing times, quantities and electronic preset counters for the detection of quantities or linear measurement as well as electronic timer. All units are distinguished by a high reliability and easy handling. Independent of the PC they indicate operating states or signal faults. This helps to reduce downtimes and production loss. Pulse evaluation systems are used for decentralised monitoring of drives. ifm electronic offers the following evaluation systems: Speed monitor Standstill monitor Slip- / synchronisation monitor Direction monitor Frequency-to-current converter Threshold relay Displays with frequency and ue input Counters Switching amplifiers Machine cycles must also be monitored in conveying.
3 Universal speed monitors s FR- dual-chamber terminals x. mm² plastics 0 AC / DC PNP / NPN / Namur DD00 FR- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DD AC/DC / 7 DC PNP / NPN / Namur DD00 FR-N dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC Namur 8. V DD0 Dual speed monitors s FR- dual-chamber terminals x. mm² plastics 0 AC / DC PNP / NPN / Namur DD00 FR- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DD AC/DC / 7 DC PNP / NPN / Namur DD006 FR-N dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC Namur 8. V DD0 Slip / synchronous monitors s FS- dual-chamber terminals x. mm² plastics 0 AC / DC PNP / NPN / Namur DS00 FS- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DS00
4 s FS-N dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC Namur 8. V DS0 FS- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DS00 FS-N dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC Namur 8. V DS0 FS- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DS006 Combined direction and speed monitors s FD- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DR00 FD- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC PNP / NPN / Namur DR00 Frequency-to-current converters s FA- dual-chamber terminals x. mm² ( x AWG ) plastics 7 DC PNP / NPN / Namur DW AC/DC / 7 DC PNP / NPN / Namur DW00 Standard speed monitors s D00 6 terminals... mm² plastics 0 AC / DC PNP DD000 / DC PNP DD AC / DC PNP DD00
5 s D00 6 terminals... mm² (AWG ) plastics AC/DC / 7 DC PNP DD AC/DC / 7 DC PNP DD0 Standstill monitors s A00 6 terminals... mm² plastics 0 AC / DC PNP... / DA000 A00 6 terminals... mm² (AWG ) plastics AC/DC / 7 DC PNP AC/DC / 7 DC PNP... / / DA06 DA0 Speed monitor with integrated sensor Sensing [mm] Electrical design Start-up delay [s] Terminal connection 0 f AC/DC AC/DC...00 DI000* 0 f AC/DC AC/DC DI000* 0 f AC/DC AC/DC...00 < 0. DI000* 0 f DC PNP DC...00 DI00 0 f DC PNP DC DI00 0 f DC PNP DC DI0 0 f DC PNP DC...00 DI00 0 f DC PNP DC...00 DI00 0 f DC PNP DC...00 DI007 0 f DC PNP DC DI009 nf DC PNP DC DI600 0 f AC/DC AC/DC...00 DI00A* 0 f AC/DC AC/DC DI00A* 0 f DC PNP DC...00 DI0A 0 f DC PNP DC DI0A 0 f DC PNP DC DI0A nf DC PNP DC DI60A f = flush / nf = non flush * Note for AC and AC/DC units Miniature fuse to IEC607- sheet, A (fast acting). Recommendation: check the unit for reliable after a short circuit.
6 Multial displays for digital signals / frequency input s FX 60 0 screw terminals... mm² (DC and inputs) plastics AC/DC /0 PNP / NPN 8 DX00 /0 PNP / NPN 8 DX00 /0 PNP / NPN 8 DX00 Universal counters s 00 coded plug-in terminal strip; screw terminals up to. mm² metal 0 AC / DC PNP / NPN 9 DZ00 00 coded plug-in terminal strips; screw terminals up to. mm² metal 0 AC / DC PNP / NPN 0 DZ00 00 coded plug-in terminal strips; screw terminals up to. mm² metal 0 AC / DC PNP / NPN DZ00 x screw terminal plug 7 poles; reference grid:.08 mm /.8 mm (X up to. mm²; X up to. mm²) plastics AC PNP / NPN E8900 -channel threshold relay for ue standard signals s A- dual-chamber terminals x. mm² ( x AWG ) plastics AC/DC / 7 DC x 0/...0 ma D00 Multial displays for ue standard signals s AX 60 0 screw terminals... mm² (DC and inputs) plastics AC/DC /0 0/...0 ma / V 8 DX0 /0 0/...0 ma / V 8 DX0 terminals up to. mm² plastics...0 ma E890 6
7 Accessories Description Pulse divider Ratio input/output pulse 0: Housing for DIN rail mounting plastics E8000 Pulse divider Division... 6 E800 Pulse stretcher Pulse length IN (min): > 0. ms / OUT: ms Housing for DIN rail mounting plastics E800 Accessories Description Angle bracket for type M8 Housing materials: stainless steel E076 Angle bracket for type M0 Housing materials: stainless steel E077 Mounting clamp Ø 0 mm - Ø 8 mm with reducing bush for type M8 Housing materials: PBT E0076 Mounting clamp Ø mm - Ø 0 mm with reducing bush for type M0 Housing materials: PBT E0077 Target wheel Plastic disk with 8 screws as target Centered drill holes E8900 Target for pulse pickups Strap dimensions 7 x 0 mm E890 7
8 Wiring diagrams 6 BN BU N BN BK BU BN BK : pulse output (the pulse sequence corresponds to the damping frequency), : switching output (adjustable) BU Scale drawings 6 7A 8A pot , : mounting on DIN rail , : mounting on DIN rail , 9 M0x, ED pot M0x, ED 6 M 6 pot Mx M0x, ED M x M8 x : mounting on DIN rail : ED, : setting pushbutton 8
9 Scale drawings , , 7 77, : mounting on DIN rail Reset 96 9 P , 7 control panel cutout: 68 x mm (according to DIN) 8 Out Reset 96 9 P , Out Out Reset P S C ED 9
10
Amplifiers, Counters, Timers & Controls
Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter
More informationSafety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC
Non-contact safety system CES-FD- Evaluation of signals in the field Connection of CES read heads Connection to the ET200s and ET200pro Familiar EUCHNER AP interface Functional description Field evaluation
More informationAdd Smarts to Your Sensor. Phone: Fax: Web: -
Add Smarts to Your Sensor Phone: 800.89.0 - Fax: 888.7.77 - Web: www.clrwtr.com - Email: info@clrwtr.com Add Smarts to Your Sensor makes your sensor or switch Smart by adding functionality to your signal
More informationOperating instructions. Monitor FS-2 / FS-2N / / 2013
Operating instructions Monitor FS-2 / FS-2N UK 7390959 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationOperating instructions. Monitor FR-1 / FR-1N / / 2013
Operating instructions Monitor FR-1 / FR-1N UK 7390953 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target
More informationInductive and Capacitive Proximity Sensors Identification Codes. Product Type/Size Output Type of Sensing Options Group of Housing Output Distance
Proximity Sensors Inductive Sensors Inductive Proximity Sensors are used when the target or object to be sensed is metal. Inductive types are the most widely used proximity sensors for industrial applications.
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationInductive Analog-Sensors
SENSOREN FÜR AUTOMATION Inductive Analog-Sensors Item group 260 Non-contacting measurement of distance and position -Distance -Displacement -Position -Edge guiding -Concentricity -Centering -Sorting -Counting
More informationInnovations Octavis fluid sensors and diagnostic systems
Innovations Octavis www.ifm.com/za fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems product news Real-time maintenance* with efector
More informationOperating instructions. Monitor FS-1 / FS-1N / / 2013
Operating instructions Monitor FS-1 / FS-1N UK 7390958 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target
More informationOperating instructions. Monitor FD / / 2013
Operating instructions Monitor FD-1 UK 7390956 / 00 01 / 2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationC5 Series Stainless Steel Photoelectric
C5 Series Stainless Steel Photoelectric Part Number Sensing Range M5 (5 mm) stainless steel - DC 14 models available Diffuse and through-beam styles Long operating distances Compact stainless steel housing
More informationCylindrical designs Smooth barrel
No matter if you choose a compact Ø 3 mm or a rugged Ø 40 mm version: The smooth barrels from TURCK are available with different switching distances, many connection possibilities and high protection rating.
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationAPS4 Inductive Proximity Sensors
APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,
More information02/11/2015
DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact
More information02/11/2015
24 x 48 Hour CTR24 non-backlit model Part number 87622162 Display : 8-digit LCD, height 8 mm Built-in module for voltage inputs 10 260 VAC/DC () 4 timing ranges : 99,999.99 hrs - 99,999.59 hrs - 999,999.9
More informationOperating instructions Control monitor for temperature sensors TR /00 04/2011
Operating instructions Control monitor for temperature sensors TR7432 704773/00 04/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 4 Function 4 4. Communication,
More informationFE Series Photoelectric Sensors
FE Series Photoelectric Mini-rectangular plastic - DC 2 models available Diffuse, polarized reflective, and through-beam models Plastic housing Axial cable or M8 quick-disconnect models NPN or PNP, Light-on/Dark-on
More informationCounting On Your Process Preset Counters
Preset Counters Preset Counters Counting On Your Process Preset Counters A broad mechanical, electromechanical and electronic product line for every application requirement 118 Product Overview Preset
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationInductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing
More informationPower Transducers. Measuring most electrical parameters
Measuring most electrical parameters Wide range of power measuring transducers including AC volts, AC current, power factor, watts, vars and phase angles measurements. Multi power monitor has output options
More informationLS series. Electrical Position Indicators for Quarter Turn Actuators
0 Electrical Position ndicators for Quarter Turn Actuators Construction The GEMÜ electrical position indicators are used to indicate and monitor the position of quarter turn valves. Depending on the version,
More informationSM9000. Magnetic-inductive flow meter. Made in Germany
Made in Germany Application Application totaliser function; empty pipe detection; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous
More informationE3Z. The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly
Compact Photoelectric Sensor with Built-in Amplifier EZ The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly Long sensing distance
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationTime Counters mini "h", DC Version
Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable
More informationSeries 100. Mechanical Switches Contents. Series 100 Multiple Position Switches
Contents Series 00 Multiple Position Switches Full size housing Full size switch elements DIN 43697 Up to 2 positions IO-Link Quick change plunger block Inductive Inductive with extended range 2 or 6 mm
More informationM30 Ultrasonic Sensor UT and UTR
M30 ultrasonic sensor with standard housing and large front sensing surface High performances and long sensing distances Adjustable hysteresis function Models with two digital programmable outputs Models
More informationVariable Area Flowmeters Installation Instructions G Series and M Series
Variable Area Flowmeters Installation Instructions G Series and M Series Safety Definitions Potential danger to life or of serious injuries. Potential for personal injury from electrical shock. Safety
More information3RG7 Opto-BERO Photoelectric Proximity Switches
K 80 Sensing range 2 m (energetic sensor) Diffuse sensors Modulated infrared light DC or AC/DC M 12 plug or moulded plastic joint IP 67 ON-delay, OFF-delay, pulse shaping Timer 0.01 s to 10 s Enabling
More informationInductive sensor NI3-EG08K-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)
More informationstandard, short, preferential, top
ipf electronic gmbh Kalver Straße 27 standard design short design preferential series top series standard, short, preferential, top norm sensing ranges, increased sensing ranges 1100 1 2 1100 norm sensing
More informationNEW. TURCK Inductive Sensors - Specialty DS20
TURCK Inductive Sensors - Specialty DS0 Sensor Selection Part Number Material Housing: Sensing Face: Connector: Chrome Plated Brass Field Wireable Connector(S578/S579): PBT Conduit Adapter (S578/S579):
More informationInductive sensor BI1.5-EG08-Y1-H1341
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationSpecial-Purpose Proximity Sensor E2C
Special-Purpose Proximity Sensor E2C Cylindrical Inductive Sensors with Separate Amplifiers Provide Variable Detecting Capabilities Separate amplifier allows sensor to fit in space-confined sites, providing
More informationTECHNICAL DATASHEET Absolute Encoder AC 58 - SUCOnet
Compact design SUCOnet or Hengstler-G1-Protocol Parameterizable: preset, direction, scaling factor, resolution PC communication via RS 485 with Hengstler-G1-Protocol Clamping flange TECHNICAL DATA mechanical
More informationThe third dimension at a glance. Visual assessment of distance, level or volume. The new 3D vision sensor.
Object recognition www.ifm.com/gb/pmd3d The third dimension at a glance. Visual assessment of distance, level or volume. The new 3D vision sensor. For industrial applications A quantum leap in optoelectronics.
More informationInductive sensor BI5-EM18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPanel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.
The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered
More information1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz
Description Operation mode and max sensing range: Diffuse proximity: 0-5 m Background suppression: 0- m Compact rectangular housing (x mm) Cable or rotatable plug connection via potentiometer Switch selectable
More informationInnovation on the right wavelength. Level measurement in compact tanks using microwave technology.
Level sensors www.ifm.com/gwr Innovation on the right wavelength. Level measurement in compact tanks using microwave technology. The innovative measuring principle for high ease of use and low cost. evaluation
More informationTemperature Switches
ETS 00 Series Temperature Switch for Inline and Tank Mounting Applications Description The ETS 00 is a compact electronic temperature switch with 4-digit digital display. Pressure resistant to 8700 psi,
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationML20 Series Long-Range Miniature Sensors
Diffuse Mode See pages 486-487 Features: Cross-talk immune for 2 units Divergent beam versions available Sensing Ranges: mm, 1 m Output: NPN, PNP Thru-Beam Mode See page 489 Features: Alignment in lens
More informationPile Driver Weld Immune Sensors
DC... 190 8, 12, 18, and 30 mm Diameter... 190 3- and 4-Wire DC... 192 8, 12, 18, and 30 mm Diameter... 192 AC/DC... 194 12, 18, and 30 mm Diameter... 194 Pile Driver Sensors P+F s weld immune Pile Driver
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationTemperature measurement TER8 Front-flush and low-invasive resistance thermometers
Product highlights 3-A fulfillment without elastomers Front-flush or immersed types Accurate reading independent on ambient temperature Fast response time Hermetically sealed towards process Capable of
More informationOperating instructions Monitor FD-2 DR2005 DR / / 2007
Operating instructions Monitor FD-2 DR2005 DR2006 UK 1 2 3 4 5 6 7 8 9 10 11 12 7390342 / 01 07 / 2007 CH1CH2 CH3CH4RUNPRGTST KEY 13 14 15 16 17 18 19 20 21 22 23 24 Content 1 Safety instructions...4 2
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationE-STOP relay, safety gate monitor
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 semiconductor output Connection options
More informationPhotoelectric Sensors E3F2
Photoelectric Sensors E3F2 Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Switch M18 DIN-sized cylindrical housing Housing materials: plastic, nickel
More informationAccessories. Accessories. Contents
Contents Accessories.2 DC connectors M connection (S26).3 M8 connection (S49, S7) DC connection cable with M8 connector (S49, S7).10 DC connection cables DC connectors MQ12 connection (S4) M12 connection
More informationAssembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II
Switch Amplifier, Timer Relay Features 1-channel signal conditioner Universal usage at different power supplies 3-wire PNP/NPN sensor or push-pull input 2 relay contact outputs Adjustable energized/de-energized
More informationSpecial-Purpose Photoelectric Sensors
Special-Purpose Photoelectric Sensors Miniature Sensors with Separate Amplifiers Fit Tight Spaces Fast, 1 ms response time Light incident indicator on sensor Dust-resistant flat lens surface New, thin
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationProduct description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors
-2 Laser Small photoelectric sensors High-performance photoelectric sensor family with laser optics Product description At a glance performance in a metal housing coating available Precise autocollimation
More informationLAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 Arithmetic functions A+B, A-B, AxB, A/B, A/B-1 applied to rate or total for channels
More informationPhone: Fax: Web: -
Housing Description Material For Sensor Types SG40/2 M6900369 Temperature resistant protective housing for CP40 Ultem Rectangular CK40 JS 025/037 M69429 Mounting rail for housingck40 Stainless steel Rectangular
More informationSensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52.
Retroreflectors Sensor Accessory AC Sensor Tester/Demonstrator Pilot Device E65 Control Unit.1 Retroreflectors and Retroreflective Tape Product............................................. 414 Application..........................................
More informationMiniature Inductive Prox TL-W
Miniature Inductive Prox Subminiature, Flat-Pack DC Sensor Fits Tight Spaces Watertight construction conforms to IP67 Space-saving mounting area, as small as 10 x 27 mm ( 0.39 x 1.06 in), is ideal for
More informationZelio Control - modular measurement and control relays 1 Speed control relays RM35 S
Presentation, description 1 Speed control relays M35 S 105687 Presentation Speed control relay M35 S0MW monitors: 2 Underspeed: without memory, with memory, 5 with inhibition by external contact. 2 Overspeed:
More informationCYLINDRICAL Inductive Proximity Sensors
Table of Contents OVERVIEW Inductive Proximity Sensors Introduction...4 Operation...5 CYLINDRICAL Inductive Proximity Sensors Introduction/Operation...8 Selection Guide, DC styles...12 Selection Guide,
More informationRotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track
Electronic multiturn gear with intelligent sensing technology (IST) Integrative Technology Max. 4 programmable outputs* for the SSI version Programmable parameters include*: code type, resolution per revolution,
More informationLS 5000 series Vibration Level Switch for liquids
Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,
More informationFeatures IP66. Installation Counting range Operation light Rated voltage Model No.
1421 Meter TH8 DC Meter * Refer to our website for details of product. RoH compliance Related Information General terms and conditions... F-3 election guide... P.1411~ PHOTO PHOTO AFETY LIGHT CURTAIN /
More informationSeries P49 - Housing M18 M30 Q50. PIL Sensoren GmbH March 2013 V1.0
- Housing M18 M30 Q50 4 Cost effectiv series for basic applications with high quantities cylindrical housing M18 M30 / cubical housing 80x80 mm for various installation and application requirements large
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationDigital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.
Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate
More informationPhotoelectric sensors infrared / redlight
infrared / redlight Selection chart Page Cylindrical housing OG (M8) Basicine DC 7 Cylindrical housing OG (M8) Performanceine DC 7-7 Cylindrical housing OG (M8) Basicine with lateral sensing face 7 Cylindrical
More informationRoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e
The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via
More informationILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector
Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationDESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications
3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for
More informationE3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.
Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection
More informationUniversal counter UZ 9648 Counting - length measurement - metering - positioning
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm
More informationSolid State Remote Power Controller E /627
Solid State Remote Power Controller E--623/62 Description The E-T-A Solid State Remote Power Controllers E--623/62 are electronic control modules suitable for inductive loads such as electromagnetic valves
More informationMain sectors of activity subject to a higher risk of explosion or fire
Main sectors of activity subject to a higher risk of explosion or fire Flour mills Wood and aluminium workshops Bagging Grain silos Grain drying areas Bulk conveying 68 SEN TRONIC AG Explosive atmospheres
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationOperating instructions Pressure sensor. PN78xx / / 2010
Operating instructions Pressure sensor PN78xx UK 704788 / 00 05 / 2010 Contents 1 Preliminary note3 1.1 Symbols used 3 2 Safety instructions 3 3 Functions and features 4 4 Function 5 4.1 Processing of
More informationY800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels
Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable
More informationSafety switches with manual mechanical delay and separate actuator
D Safety switches with manual mechanical delay and separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF VF KEYF VF KEYF7 VF KEYF ACTUATORS MECHANICAL DELAY C L L0 Short knob 0 sec. Short knob sec.
More informationMagnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More informationPERFECT HANDLING. PCB Front Panels & Injector/Extractor Handles... Package Your Electronics With Ripac.
Front Panels & Injector/Extractor Handles... PERFECT HANDLING. Package Your Electronics With Ripac. When it comes to electronics, no one handles today s demanding applications better than Rittal Ripac
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationHR1S-AC Safety Relay Modules
HRS-AC Relay Modules Transistor output provided. Removable terminal block (HRS-AC52P) allows for easy module replacement. Fault diagnosis function with dual safety circuits. Internal relay operations can
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-D Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Programming...5 Control s...6 Order Code & Accessories...7
More information7511 / / / 711 / / 731 / Preset 27
22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer
More informationDigital electropneumatic positioner
Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)
More informationDisplays Transducers. Displays and transducers
JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow
More informationBOS 73K... BOS 74K...
BFB/BOS When there s no space for a photoelectric sensor, there is only one solution: user fiber optics! If there are no particular demands for toughness an ambient temperature or chemical resistance,
More information93 SERIES. Timed socket for 34 series 93.68/93.69
93 93 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch for selection of 4 time scales and 8 functions
More informationPNP - two digital outputs with standard window and adjustable hysteresis functions
UK and UKRseries M8 cylindrical direct diffuse & retroreflective Ultrasonic Sensor UK with warranty features warranty Models with digital prograable output Models with current or voltage analogue outputs
More information3.3. Control Relays and Timers
. Contents Description easy500/700/800..... easy802/806 with SmartWire-DT.................... easyrelay and MFD Expansion Modules..... MFD-Titan Multi-Function s......... easyrelay Communication Modules........
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More information