Magnescale Co., Ltd. Digital Gauge General Catalog

Size: px
Start display at page:

Download "Magnescale Co., Ltd. Digital Gauge General Catalog"

Transcription

1 Magnescale Co., Ltd. Digital Gauge General Catalog

2 Magnescale s advanced ball-spline construction allows for smoother measurements while also increasing side-load capacity, torsion resistance and performance up to 6 million strokes. This innovative new construction allows for high precision measurements even in the most severe environments. This is the new DK-S Series. 1ch MR element pattern Metal base (m+1/2)p MR element (n+1/2)p P P/ V Ch+ G Ch MR element Conceptual diagram Magnetic media P Base Magnetic media Scale Magnescale magnetic technology diagram 2 3

3 Features & Superiority DK8S Series Adapts bearings of new construction superior in sliding force and durability. It has slim shape whose main body size is φ8 mm and is high-precision digital gauge suitable for automatic measurements. Achieved number of strokes: 6 million Maximum resolution:.1 µm Easy integration into machines with compact square body. Compact size and high rigidity It is suitable for general purpose and automatic measurements. Compact LT Series counters of DIN size Current, maximum and minimum, and P-P value measuring function Comparator 2-axis ADD/SUB function BCD/ input/output Reference point function Multipoint measurement Intelligent Network Systems: MG4 series Equipped with Ethernet interface as standard and supporting CC-Link Unit: MG1/2/3 series Equipped with interface as standard Response Speed: m/min (at resolution of.5 µm) Adopt: IP67 rating with bellows Linear encoder technology allows high precision measuring over the entire range. DK Series High rigidity Φ2mm body is suitable for harsh environments. Also, it enables high response speed in automatic measurements. According to varied materials to be measured, measuring force can be selected. Available in lengths up to mm with.5µm resolution. Magnetic feeler tips equipped as standard make it easy to integrate into machines. (DK155/) Multifunctional counters Optional expansion boards available (LY71) BCD output(ly71) (at resolution of.5 µm) Comparator(Relay,open collector output) (LY71) RS232-C (LY72) Linear encoder technology allows high precision measuring over the entire range. 4 5

4 Lineup Measuring range 5 mm 1 mm mm mm 3 mm 32 mm 5 mm 1 mm 11 mm 155 mm mm.1 µm DK85SAR/SALR DK85SAFR/SAFLR DK85SBR/SBLR DK85SBFR/SBFLR DK8SAR/SALR DK8SAFR/SAFLR DK8SAVR DK8SBR/SBLR DK8SBFR/SBFLR DK8SBVR DK83SR/SLR/SVR P. P.13 P.14.5 µm DK85SAR5/SALR5 DK85SAFR5/SAFLR5 DK85SBR5/SBLR5 DK85SBFR5/SBFLR5 DK1NR5/PR5/PLR5 DK8SAR5/SALR5 DK8SAFR5/SAFLR5 DK8SAVR5 DK8SBR5/SBLR5 DK8SBFR5/SBFLR5 DK8SBVR5 DKNR5/PR5 /NLR5/PLR5 DK5NR5/PR5 P.16 DK1NR5/PR5 DK11NLR5 (Stand and balancer are optional.) P.18 DKPR5 P.16 DK155PR5 P.17 P. P.15 P.13 P.15 P.17 DT5N/P 1 µm P.2 DTN/P DT32N/NV/P/PV 5 µm P.2 P. 6 7

5 Application Assembled part measurement and shim selection Flatness measurement of compact motors Thickness and Flexure measurement measurement of compressor parts Magnetic technology ensures consistent measurements, even in harsh environments. Measurements can be taken immediately upon turning up. Cylinder block flatness measurement Bearing height measurement Toe and alignment test Crimp-on terminal caulking height Thread height Turbine blade shape measurement Camber measurement of diecast chassis parts, etc. Thickness and inner and outer diameter measurements Film thickness measurement Tapered roller bearing measurement Digital measurement system assures full-stroke accuracy and supports multiproduct lines. Magnetic technology ensures consistent measurements, even in harsh environments. The DK-S Series has been achieved 6 million strokes, Motor shaft run-out measurement The new construction of spindle bearings Others tight spaces at narrow measuring pitches. Cam shaft run-out and shape measurement Bearing inner diameter measurement Digital data output allows for real-time measurements. The DK-S Series has been achieved 6 million strokes, Measurements on a surface grinding machine Shim thickness measurement Gasket thickness measurement, etc. Others Crank shaft journal run-out measurement Drive shaft or propeller shaft run-out measurement Bearing part run-out measurement, etc. ensuring years of service. Displacement and stop position measurement Work alignment measurement Roller-to-roller gap measurement Magnetic technology assures protection against impact resistance. Others CVT belt thickness measurement Metal plate and resin plate thickness measurement Steel ball diameter measurement increases both side-load capacity and torque resistance. Disk run-out measurement Measurements can be taken immediately upon turning up. Real-time digital data output allows gauges to be used for position control applications in a full closed-loop system. Pressing machine s or injection molding machine s stop position measurement Others Top and bottom dead center control of piston parts Measurement of material strength (such as camber) press-fit amount measurement, etc. ensuring years of service. 8 9

6 System Gauges Interface units MG1 MG2 MG3 DT s LT1A DT32 Gauges DT5 LT11A MG41 MG42 MG43 DK-S DK LT3 Description of digital gauge model [] 5 : 5mm : mm 3 : 3mm [] No symbol :.1 µm 5 :.5 µm [With reference point] [Shape] No symbol : straight L : right angle V : pneumatic push [ shape] F : flange type [Minimum phase difference] A : 5ns B : 1ns [Ball spline model] [ diameter] DK85S DK8S 13 DK83S 14 Adapter or cable LY71 LY72 * For the DK11 Series, see the specifications sheet. [] 5 :.5 µm [With reference point] [Protection grade] N : IP5 P : IP64 [Measurement range] [Spindle drive system] [Protection grade] N : IP5 P : IP64 [Measurement range] : mm 32 : 32mm DK1/ 15 DK5/1 16 DK155/ 17 DK11 18 DT5/ 2 DT32 MT/13/14 22 U Series

7 DK DK85S DK DK8S.1µm.5µm 5mm A/B phase.1µm.5µm A/B phase Gauge Measuring range High-resolution models 5 mm General-purpose resolution models Maximum resolution.1 µm.5 µm 1 µm 1.5 µm Upward:.35±. N Maximum response speed m/min 1 m/min Reference point Reference-point response speed Spindle drive system Number of cycles tested *1 Position at spindle movement of 1mm Same as the noted maximum response speed 6 million Protection grade *2 *3 ) Vibration resistance 2 to 2 Hz 1 m/s 2 Impact resistance 1 m/s 2 11 ms Operating temperature to 5 C Storage temperature Power supply 5 VDC±5 % Mass cable length 1 W Approx. 3 g Carbide ball tip, Mounting screw M2.5 Steel ball tip, Mounting screw M2.5 Accessories Cable () () 4 M9 M Gauge Measuring range High-resolution models mm General-purpose resolution models Maximum resolution.1 µm.5 µm 1 µm 1.5 µm Horizontal:.5±.3 N.7±.5 N (Pneumatic push type) Maximum response speed m/min 1 m/min Reference point Reference-point response speed Spindle drive system Number of strokes *1 Position at spindle movement of 1mm Same as the noted maximum response speed 6 million Protection grade *2 *3 ) Vibration resistance 2 to 2 Hz 1 m/s 2 Impact resistance 1 m/s 2 11 ms Operating temperature to 5 C Storage temperature Power supply 5 VDC±5 % Mass cable length 1 W Approx. 3 g Carbide ball tip, Mounting screw M2.5 Steel ball tip, Mounting screw M2.5 Accessories () () Cable () () () () () () () () ø4.8 ø4.8 ø M M M9 M Thickness: Thickness: t = t 15.2 = 15.2 mm mm M9 Thickness: t = 15.2 mm M9 M9 Thickness: t = 15.2 mm Thickness: t = mm 11 Cable Cable length length.3.3 m m Cable length.3 m 11 Cable Cable length length 2m 2m Cable length 2m 11 Cable length.3 m Cable length.3 m Cable length 2m Cable length 2m (Pneumatic push model) ø4.8 ø M9 M9 M9 5.8 (28) (28) (28) (28) (28) ø4.8 ø4.8 ø4.8 ø4.8 ø4.8 13

8 .1µm.5µm 1µm 5µm DK DK83S.1µm A/B phase.3.5 DK DK1/.5µm µm.5µm 1µm 5mm 5µm 5mm 1mm.3 A/B phase 1mm 6mm Cable 5mm length 2.5m.5 5mm * DK5NR5/PR5 Gauge Measuring range Maximum resolution Cable Cable length Cable length Cable length Straight model Right angle model Pneumatic push type 3 mm.3 Cable length 2.5m.5 5mm 1mm DK1NR5/PR5 6mm A/B phase.3 DK1/ Gauge BCD Cable 6mm Communication Communication A/B phase Ethernet CC-Link.3 Communication Communication Ethernet CC-Link BCD DKNR5/PR5 Go/no-go.3 judgment.3.3 Communication 5mm Ethernet Go/no-go judgment Communication CC-Link Cable length 2.5m BCD.5 Cable length 2.5m Go/no-go judgment DK1PLR Standard model Protected type model Standard model Protected type model Standard model Protected type model DK1NR5 DK1PR5 DK1PLR5 DKNR5 DKPR5 DKNLR5 DKPLR5 Measuring range 1 mm mm Maximum resolution.5 µm Cable length 2.5m.5 DKNLR5/PLR Cable length 2.5m Cable length Cable 2.5mlength 2.5m Cable length 2.5m Cable length 2.5m µm 1.7 µm Maximum response speed Upward:.5±.35 N Horizontal:.6±.35 N Downward:.7±.35 N Upward:.5±.35 N Horizontal:.6±.35 N Downward:.7±.35 N 2 µm Maximum response speed Upward:.3±. N Horizontal:.6±.3 N Horizontal:.7±.35 N m/min Horizontal:.7±.35 N Reference point Position at spindle movement of 1mm Reference point Position at spindle movement of 1 mm Reference-point response speed Same as the noted maximum response speed Reference-point response speed Same as the noted maximum response speed Spindle drive system Spring push Pneumatic push Spindle drive system Spring push Achieved number of strokes *1 6 million 3 million Protection grade *1 IP5 IP5 IP5 Protection grade *2 IP53 IP53/IP67 *3 Vibration resistance 1 to 2 Hz 15 m/s 2 Vibration resistance 2 to 2 Hz 1 m/s 2 Impact resistance 15 m/s 2 11 ms Impact resistance 1 m/s 2 11 ms Operating temperature to 5 C Operating temperature C to 5 C Storage temperature Storage temperature Power supply 5 VDC±5 % Power supply 5 VDC±5 % 1 W 1 W Mass *2 Approx. 23 g Approx. 3 g Mass Approx. 7 g cable length cable length Carbide ball tip, Mounting screw M2.5 Carbide ball tip, Mounting screw M2.5 Accessories Accessories *1 Excluding the interpolation box and connector *2 Excluding cable section and interpolation box 14 15

9 DK DK5/1 DK DK155/.5µm 5mm A/B phase.5µm A/B phase DK5/1 Gauge Standard model Protected type model Standard model Protected type model DK5NR5 DK5PR5 DK1NR5 DK1PR5 Measuring range 5 mm 1 mm Maximum resolution.5 µm 2 µm Maximum response speed Reference point DK5NR5/PR5 Cable () (51) Reference-point response speed * DK5NR5/PR5 * DK155PR5 DK155PR5 Downward: 1.3±.5 N (.5) 6.2 N or less DK1NR5/PR5 () () 41 m/min 444 Position at spindle movement of 1 mm Downward: 2.7±.55 N Same as the noted maximum response speed (.5) DK155/ Gauge DK155PR5 DKPR5 Measuring range 155 mm mm Maximum resolution.5 µm 5 µm 6 µm Maximum response speed Reference point Reference-point response speed Spindle drive system Protection grade *1 Cable 9.7 DKPR5 9.7 () () to m/min Position at spindle movement of 5 mm Same as the noted maximum response speed None (.5) (.5) Spindle drive system Spring push Protection grade *1 IP5 IP5 Vibration resistance 1 to 2 Hz 15 m/s 2 Impact resistance 15 m/s 2 11 ms Operating temperature to 5 C Storage temperature Power supply 5 VDC±5 % Mass *2 Approx. 36 g Approx. 63 g cable length Carbide ball tip, Mounting screw M2.5 1 W Vibration resistance 1 to 2 Hz 15 m/s 2 Impact resistance 15 m/s 2 11 ms Operating temperature to 5 C Storage temperature Power supply 5 VDC±5 % Mass *2 Approx. 11 g Approx. 13 g cable length Surface to be measured Magnetically attachable feeler Spindle *3 Accessories 1 W Soft magnetic material Accessories *1 Excluding the interpolation box and connector *2 Excluding cable section and interpolation box *1 Excluding the interpolation box and connector *2 Excluding cable section and interpolation box 16 17

10 DK DK11.5µm A/B phase A B Reference-point output DK8SA output signal at maximum response speed (at approx. 8 m/min) 2 ns (5 MHz) DK8SB output signal at maximum response speed (at approx. 42 m/min) 4 ns (2.5 MHz) DK1//1/155//11 output signal at maximum response speed (at approx. m/min) 2 ns (5 MHz) A A A DK11 Gauge Measuring range Cable DK Series measuring unit output signals The reference point is synchronized with A and B phases at high impedance. (Note: this may not be worded correctly) DK11NLR5 11 mm Maximum resolution.5 µm B 5 ns The A/B quadrature output signal by measuring unit is 5 MHz maximum Phase A/B Minimum phase difference 5ns 1ns 3ns 5ns Phase A single cycle 2ns 4ns B s permissible frequency 5MHz 2.5MHz 8kHz 5kHz 1 ns with a minimum phase difference of 5 ns for DK8SA and is 2.5 MHz maximum with a minimum phase difference of 1 ns for DK8SB. The counter or control devise capable of processing these signals should be used. Moving length of the measuring unit is detected every 5 ns for the DK8SA/DK and every 1 ns for the DK8SB, and the phase difference proportional to the amount traveled is output. The amount of phase difference changes in integer multiples of 5 ns or 1 ns. Also, the minimum phase difference for the phase A and B is 5 ns for the DK8SA/DK and 1 ns for the DK8SB. If the response speed is exceeded, the phase A/B output from this measuring unit changes to high impedance state A B 8m/min 42m/min 14m/min 8.4m/min Integral multiple of 5 ns or 1 ns Maximum response speed Line driver : A/B/reference point B m/min 1m/min m/min 2m/min 5 ns For DK the A/B quadrature output signal by measuring unit is 5 MHz maximum with a minimum phase difference of 5 ns. The counter or control devise capable of processing these signals should be used. Signal Alarm Signal Phase Difference Receiver 19.5 m or less (excluding 2.5 m standard cable) Remarks DK8SA standard product DK8SB standard product Special specifications Special specifications Receiver Line receiver AM26C32 or equivalent Maximum response speed m/min Reference point Reference-point response speed Spindle drive system Position at spindle movement of 5 mm Same as the noted maximum response speed Spring push Alarm section Phase A/B is in high impedance state. * If extending the cable (Magnescale-specific cable), the supply voltage should be +5 V ±5% at the extension destination. *For an extension cable with spread-out end, use the CE22 Series. Protection grade *1 Vibration resistance 1 to 2 Hz 15 m/s 2 Impact resistance 15 m/s 2 11 ms IP5 DK Series operating cautions Operating temperature to 5 C Storage temperature Power supply 5 VDC±5 % 1 W on the usage condition. A precision pressure regulator (e.g., SMC IR or equivalent) should be used. Mass *2 cable length *1 Excluding the interpolation box and connector *2 Excluding cable section and interpolation box Carbide ball tip, Mounting screw M2.5 Accessories Fig. 1 Pneumatic circuit (pneumatic push) AIR Mist separator Pressure P R A source Air filter Regulator Solenoid valve Precision regulator Speed controller Fig. 2 Pneumatic circuit (vacuum suction) EXE Speed controller AIR Mist separator P V Pressure P R A source Air filter Regulator Solenoid valve Vacuum ejector 18 19

11 DT DT5/ DT DT32 1µm 5µm 5µm DT5N/N DT5P/P 6 (27) 1 Gauge Interpolator Adapter DT Gauge Interpolator Adapter 6 (27) 1 * DT5P * DTP DT32N (35) 15 (81) 95 DT32P (35) (81) (35) 5 1 ø DT32PV (35) DT2 Gauge 5 1 ø8 Interpolator Adapter DT32NV 35 5 ø Cable length 2m Cable length 2m Measuring range *2 Excluding the connector *3 Excluding cable section Standard model Protected type model Standard model Protected type model DT5N DT5P DTN DTP Maximum resolution 1 µm 5 µm 6 µm 1 µm Maximum response speed Reference point Spindle drive system Achieved number of strokes *1 Upward:.7±.5 N 1.7 N or less in all directions mm Depending on unit to be connected None Spring push-out 5 million Upward:.7±.5 N 1.7 N or less in all directions Protection grade *2 Operating temperature to 5 C Storage temperature Mass *3 Approx. 75 g Approx. 75 g cable length Steel ball tip, Mounting screw M2.5 Accessories 2 m Instruction Manual Measuring range Standard model Protected type model DT32N DT32NV DT32P DT32PV 32 mm Maximum resolution 5 µm 1 µm Maximum response speed Reference point Depending on unit to be connected None Spindle drive system Spring push-out Pneumatic push Spring push-out Pneumatic push Achieved number of strokes *3 Protection grade 5 million Operating temperature to 5 C Storage temperature Mass *5 Approx. g Approx. g cable length Provided with a steel ball tip, Mounting screw M2.5 Accessories *1 *2 2 m Instruction Manual 2

12 5mm 1mm 5mm MT MT/13/14 U U Series A/B phase Communication Communication Ethernet CC-Link 5mm 6mm A/B phase 1µm 6mm BCD Go/no-go judgment MT /13 Measuring unit connector Cable Display unit connector A/B phase Cable length: 3 connector 32 Cable * The air release and the gauging stand are optional accessories. 98 Cable length: 3 UB U3B U6B * Connection of the DT Series enables A/B phase output. Gauge Interpolator Interpolator Interpolator Cable color MT signal: Phase A/B Alarm output format: NPN open collector output (max. rated voltage: 31 V, max. rated current: 5 ma) Pin no. Description Cable color 1 +5 V Red 2 3 V Black A Yellow 5 B Blue 6 7 ALARM Gray V Purple 1 V Orange Case Shield connected to cables with colors not found in this table. To various control device Cable color MT13 signal: Phase A/B (The output becomes High impedance during an alarm.) format: Voltage-differential line driver output (compliant with EIA-422) Pin no. Description Cable color 1 +5 V Purple 2 V Black 3 A Blue A Yellow 5 B Orange 6 B Gray 7 Case Shield connected to cables with colors not found in this table. Phase difference for phase A/B output MT -1 MT -5 MT -1 phase difference (µs) Velocity: v (m/min) * An alarm is output at a traveling velocity of 1 to 115 m/min. The sampling frequency of the output signal is µs. MT MT13 A, B, ALARM A, B Cable color MT14 signal: A/B phase, alarm (The output does not become High impedance during an alarm.) format: Voltage-differential line driver output (compliant with EIA-422) Description Cable color +5 V Red V White V Brown V Black A A B B ALARM ALARM A, B, ALARM A, B A, B, ALARM Yellow Blue Gray Orange Purple Green Shield M 1 () UB U3B U6B Measuring range mm 3 mm 6 mm Maximum resolution 1 µm M 1 () M 1 () MT-5 MT-1 MT13-1 MT13-5 MT µm 3 µm 1.3 N or less 1.5 N or less 2.2 N or less Travel length of the release 32 mm Compatible measuring units DT5, DT/DT32 Display LCD display element (6 digits, minus display) Maximum response speed 1 m/min Maximum response speed 5 µm 1 µm 1 µm 5 µm 1 µm 1 µm 5 µm 1 µm Operating temperature Power voltage 5 VDC±5 % Storage temperature Power supply format Open collector A/B Voltage-differential line driver Operating temperature and humidity range Storage temperature and humidity range to 5 C (No condensation) Mass Approx. 23 g Approx. 3 g Carbide ball tip, Mounting screw M2.5 1 W Mass Accessories Instruction Manual, AC adapter available (We DO NOT provide an AC adaptor with these.), lift lever, and dedicated spanner 22 23

13 Installation DK5/1 installation cautions Mounting holder dimensions and tolerance Mounting holder configuration dimensions (for reference) M M Feeler Spindle Dedicated spanner Tightening torque:.6 Nm Material: In case of SUS Fixing position 16 Tightening torque: 4 Nm Hex. socket head bolt M4 is used Lock pin Measuring unit The recommended value of measuring unit mounting The mounting thickness is as follows: DK155/DK installation cautions Mounting plate Mounting parallelism affects measurement accuracy. Mounting holder configuration dimensions (for reference) Feeler Spindle Dedicated spanner Wave washer Tightening nut Clamp spanner Adjust the squareness to the surface to be measured or or less. 1 M Mounting holder dimensions and tolerance Sleeve +. M Feeler Spindle Tightening torque: 6 Nm Hex. socket head bolt M5 is used. Dedicated spanner Tightening torque:.6 Nm Material: In case of SUS DK1/ installation cautions DT/5/32 installation cautions Mounting method using mounting hole Mounting method using holder Mounting holder dimensions and tolerance Mounting holder configuration dimensions (for reference) 2-M4 screw + washer 2-M4 tapping Mounting holder M M Tightening torque:.18 to.23 Nm +.2 ø8 +.1 Fixing position Material: In case of S45C Tightening torque: 4 Nm Hex. socket head bolt M4 is used

14 Interface unit MG4 Series 28 MG1/2/

15 A/B phase A/B出力 MT接続時 A/B phase Series Ethernet I/O出力 Display unit judgment Multi Interface Unit Counter Module MG2-DK Serial No Multi Interface Unit BCD Module MG30 B1 Serial No I/O DC-IN LINK-OUT SIG BCD I/O FG Remarks 1 to 1 units (Connection of 11th unit and later disabled) RESET ADDRESS RES DIR LINK-IN DC12 24V Serial No 4-M3 Depth 8 or less Multi Interface Unit Main Module MG10 P1 13 MG1-P1 Power supply Inrush current (1 ms) Power supply protection MG1-P2 2. W + total power consumption for connected modules*1 1 A or less (when maximum number of modules are connected) Communication Settable output data resolution and display resolution.5 µm 1 µm 5 µm 1 µm.5 µm 1 µm 5 µm 1 µm Maximum 1, data/sec (when 1 axes are connected) Calculation of maximum, minimum, and peak-to-peak values for each axis (including pause, latch, and start functions) Peak value is not updated during pause. No output and display data updated during latching (but internal data is updated) Recalculation of peak value is started by start function. Current, maximum, minimum, and peak-to-peak values for each axis.1 µm Data for one axis is counted as one data. Linkage function Input format I/O Cautions for connecting conditions When master calibration function is not used Measuring unit input Maximum response speed Maximum response acceleration Reference point Others Alarm DT Series 1/5/1/.5/.1 µm 5 µm(dt/32) 1 µm(dt5) Set with DIP switch 1m/s 2 reference point is detected. Set or preset value on the counter when the reference point is detected. S-ALM LED activates by excess speed/acceleration of measuring unit. C-ALM LED activates by excess speed of the internal circuit of counter. The Alarm display is cancelled by reset command from MG1 or with the reset button of main unit. MG3-B1 MG3-B2 1W Input format I/O Hub units supported by the main unit Measuring units supported by the main unit and hub units Measured data monitoring, system monitoring, setting monitoring DK Series (Voltage differential A/B quadrature input) *2: Set the resolution value of the connected gauge. * If DK8S connected to MG4 is connected to LT3 or MG1/2, the reference point cannot be recognized. For more information, contact our Sales Dept. in charge. * Connection of MG41 to MG43 using Ethernet connection requires an additional Ethernet hub. Network interface Power supply Operating temperature & humidity range Storage temperature & humidity range Mass MG2-DT 1 W + power consumption for connected gauge Allowable resolution setting*2 to +5 C (no condensation) Item *1 MG2-DK Corresponding gauge If system power consumption exceeds the maximum current, supplying power to a succeeding MG42 hub unit enables the main unit to be connected to the succeeding MG42 hub unit. Description Reset, pause, start, latching, and data out trigger to whole channels Integrated alarm MG2-DK, MG2-DG, and MG-2DT (available for mixed use, up to 16 modules)*1 When master calibration function is not used Addition and subtraction axes are unavailable. Used by adding power at a current of 4A or more on a six MG42 hub units basis. (Recommended: +24 V) Operating temperature and humidity range Storage temperature and humidity range Mass Input signal signal modules Interface modules LY LY Terminal board Connectable modules Source type (+COM) format LT LT Supply voltage 1 m Source input (+COM) MG MG Command input, data output, and parameter setting enabled. The Current value for each axis is reset (with command). The Value is preset to the current value of each axis (with command). The Datum point of each axis is settable (with command). The datum point of each axis can be reproduced using the reference point (with command). Master calibration of each axis can be reproduced using the reference point (with command). The product information of the connected measuring unit can be acquired (with command). Product code, serial no., production date Ethernet CC-Link Reset function Preset function Datum-point setting function Reference point function Master calibration function Command Comparator value setting Comparator group number setting Start Pause Latch Current value/peak value (All axes) Current value/peak value (each unit) Comparator judgment result Data output Alarm (Communication/Measuring unit) Software version Measuring unit product information Input resolution Display and output resolution Settings Axis addition Command/setting enabled or disabled for each communication line 1 / 2 bit (set with DIP switch) None / ODD / EVEN (set with DIP switch) Single-axis calculation of addition and subtraction axes is disabled. Current, maximum, minimum, and peak-to-peak values of addition and subtraction axes of two axes Data of each axis (single axis, addition/subtraction axis) is compared and measured to output the comparator results (Comparator is also latched during latch) 2 values 16 values 16 groups 2 groups Reset function Preset function Datum-point setting function Reference point function Master calibration function Measuring unit product information Baud rate setting Data length Stop bit Parity Delimiter Maximum number of linkages Maximum length of linking cable U U At addition and subtraction Comparator function Comparator setting values No. of setting value sets Ethernet DT(MT) DT(MT).1 µm.5 µm 1 Mbps data transfer Single axis Compatible main units Compatible hub units Compatible measuring units Main functions Communication protocol Screen display (EIA-232C or equivalent) Peak-hold function Item Connection cable length -enable data MG3-B1/B C-SET +1 Connectable measuring units Measuring unit resolution (Input resolution) Measuring unit data fetching capacity MG2-DK/DT.1 Power source Entire system Go/no-go judgment MG1-P1/P M2 Depth 8 or less 67.4 Communication method No. of connectable measuring units BCD Unit No. Description Conditions, etc Depth 8less or less less 4-M34-M3 4-M3 Depth Depth 8 or 8 or 2-M2 2-M22-M2 88 or DepthDepth Depth 8 or less or less less M2 Depth 8 or less Item CC-Link DK DK 43 2-M22-M2 2-M2 Depth or less less DepthDepth 8 or less 88 or A/B出力 MT接続時 DKS DKS (for Ethernet) Hub unit (for CC-Link, Ethernet) 3 3 Main unit Go/no-go BCD Communication Communication CC-Link Main unit I/O出力 6mm Communication Communication Ethernet MG MG1/2/3 6mm 5mm mm MG MG4 5mm 1mm 5mm 1mm format Input signal signal Description Source type (+COM) part output circuit: current sink input ( COM) Current sink input (+COM) part output circuit: source type (+COM) Current sink input ( COM) part output circuit: source type (+COM) Source type (+COM) part output circuit (+COM): source type ( COM) DRQ / channel address / measuring mode shifting / comparator shifting / reset / start / posing / reference-point loaded BCD data (6 digits) / READY / code / Go/No-go output / alarm / reference-point setting Approx. 5 g All models Operating temperature Storage temperature to +5 C(No condensation) 29

16 Installation The multi-interface unit is composed of various modules. MG1/2/3 connection unit with the upper side of DIN rail. module (MG2) Main module (MG1) Note: Check that the entire unit is mounted to the DIN rail. Mounting to DIN rail 1. Match the upper side of groove on the back of the unit with the upper side of DIN rail. 2. Push and install the unit until a click is heard so that the lower Panel cutout diagram M M3 6 (washers, spring washers) Reference: If a mounting screw hole cannot be drilled in the on the back of the main unit

17 LT3 Series 34 LT11A Series 35 LT1A Series 36 LY71 37 LY

18 LT LT3 Series (for DK, DK-S) LT LT11A Series (for DT5) BCD Go/no-go judgment BCD Go/no-go judgment LT3-2GB (71.8) LT3-1G LT3-1GB (BCD output model) LT3-1GC ( input/output model) LT3-2G LT3-2GB (BCD output model) LT3-2GC ( input/output model) LT11A-11 LT11A-11B (BCD output model) LT11A-11C ( input/output model) LT11A- LT11A-B (BCD output model) LT11A-C ( input/output model) Number of input axes DK Series gauges can be connected. 1 axis 2 axes Number of input axes DT5 Series gauge can be connected. 1 axis 2 axes Input resolution.1/.5/1/5/1 µm (parameter setting for each axis) Number of display axes 1 axis 2 axes Display data Display resolution Direction Alarm display Current, max., min., and peak-to-peak values (= max. value min. value) Current, max., min., and peak-to-peak values (= max. value min value) of each axis or A-axis display: current, max., min., and peak-to-peak values (= max. value min value) of 2-axis addition and subtraction B-axis display: single axis (1st or 2nd axis) (Caution for 2-axis addition or subtraction display setting: single-axis display can be only provided on monitor and cannot be operated.) (Selected by parameter setting) Same resolution as input resolution or resolution rougher than that can be selected for each axis (parameter setting). Parameter-based polarity setting for each axis Addition and subtraction function A+B, A B, B A can be set with the direction setting. Peak hold function Peak calculation (max., min., and peak-to-peak values) is possible. Peak calculation of each axis or addition/subtraction value is possible. (However, during 2-axis addition or subtraction, only 1st or 2nd axis display is possible in B-axis display.) Restart Starts peak hold calculation of each axis. Operation is made by external input. Starts peak hold calculation of each axis. Operation is made by external input (for each axis). Hold function (latch and pause) Latch = display and output holding Pause = peak calculation holding Comparator function Input signal A set of upper and lower limits is settable. lower limits are settable. Switching of a set is made through BCD connector. A set of upper and lower limits is settable. Provided A set of upper and lower limits is settable for each axis. However, single-axis setting cannot be made during addition or substation. Reset, start/latching, and pause of each axis RS-TRg input ( data output command) Four sets of upper and lower limits are settable for each axis. However, single-axis setting cannot be made during addition or substation. Switching of a set is made through BCD connector. A set of upper and lower limits is settable for each axis. However, single-axis setting cannot be made during addition or substation. RS-TRg input ( data output command) Input resolution 1/5/1 µm (parameter setting for each axis) Number of display axes 1 axis 2 axes Display data Display resolution Direction Alarm display Current, max., min., and peak-to-peak values (= max. value min. value) Same resolution as input resolution for each axis Parameter-based polarity setting for each axis Current, max., min., and peak-to-peak values (= max. value min value) of each axis or A-axis display: current, max., min., and peak-to-peak values (= max. value min value) of 2-axis addition and subtraction B-axis display: single axis (1st or 2nd axis) (Caution for 2-axis addition or subtraction display setting: single-axis display can be only provided on monitor and cannot be operated.) (Selected by parameter setting) Addition and subtraction function A+B, A B, B A can be set with the direction setting. Peak hold function Peak calculation (max., min., and peak-to-peak values) is possible. Peak calculation of each axis or addition/subtraction value is possible. (However, during 2-axis addition or subtraction, only 1st or 2nd axis display is possible in B-axis display.) Restart Starts peak hold calculation. Operation is made by external input. Starts peak hold calculation of each axis. Operation is made by external input (for each axis). Hold function (latch and pause) Latch = display and output holding Pause = peak calculation holding Comparator function Input signal A set of upper and lower limits is settable. lower limits are settable. Switching of a set is made through BCD terminal. A set of upper and lower limits is settable. Provided A set of upper and lower limits is settable for each axis. However, single-axis setting cannot be made during addition or substation. Reset, start/latching, and pause of each axis RS-TRg input ( data output command) Four sets of upper and lower limits are settable for each axis. However, single-axis setting cannot be made during addition or substation. Switching of a set is made through BCD connector. A set of upper and lower limits is settable for each axis. However, single-axis setting cannot be made during addition or substation. RS-TRg input ( data output command) signal Comparator judgment output of each axis signal Comparator judgment output of each axis Comparator judgment output BCD output Current value and peak value (max., min., and peak-to-peak values) can be output. NPN open collector output Current value and peak value (max., min., and peak-to-peak values) can be output. Comparator judgment output BCD output Current value and peak value (max., min., and peak-to-peak values) can be output. NPN open collector output Current value and peak value (max., min., and peak-to-peak values) can be output. input/output Each function can be activated using command instead of key operation. Current, max., min., and peakto-peak values can be output using data output command. Each function can be activated using command instead of key operation. Current, max., min., and peakto-peak values can be output using data output command. input/output Each function can be activated using command instead of key operation. Current, max., min., and peakto-peak values can be output using data output command. Each function can be activated using command instead of key operation. Current, max., min., and peakto-peak values can be output using data output command. Reset Preset Key operation Reset can be made by key operation or external reset input. Key operation or command via Key operation Key operation or command via Reset Preset Key operation Reset can be made by key operation or external reset input. Key operation or command via Key operation Key operation or command via Master calibration function Master calibration function Reference point function Reference point function Key lock function Key lock function Power supply Power supply 5 W 5.5 W 5 W 2. W 2.3 W 2.5 W Operating temperature range Operating temperature range Storage temperature range Storage temperature range Mass Approx. 2 g Approx. 23 g Approx. 22 g Approx. g Approx. 27 g Approx. 23 g Mass Approx. 2 g Approx. 23 g Approx. 22 g Approx. g Approx. 27 g Approx. 23 g 34 35

19 LT LT1A Series (for DT/32) LY LY71 BCD Go/no-go judgment BCD Go/no-go judgment M5 Max. depth: (71.8) 245 (1.5) 44 (3) (3.7) M4 Max. depth: (31.5) Number of input axes LT1A-15 LT1A-15B (BCD output model) LT1A-15C ( input/output model) LT1A- DT/32 Series gauges can be connected. LT1A-B (BCD output model) 1 axes 2 axes LT1A-C ( input/output model) (9.5) Input resolution 5/1 µm (parameter setting for each axis) Number of display axes 1 axes 2 axes Display data Display resolution Direction Alarm display Current, max., min., and peak-to-peak values (= max. value min. value) (selected by parameter setting) Same resolution as input resolution for each axis Parameter-based polarity setting for each axis Current, max., min., and peak-to-peak values (= max. value min value) of each axis or A-axis display: current, max., min., and peak-to-peak values (= max. value min value) of 2-axis addition and subtraction B-axis display: single axis (1st or 2nd axis) (Caution for 2-axis addition or subtraction display setting: single-axis display can be only provided on monitor and cannot be operated.) (Selected by parameter setting) Addition and subtraction function A+B, A B, B A can be set with the direction setting. Peak hold function Peak calculation (max., min., and peak-to-peak values) is possible. Peak calculation of each axis or addition/subtraction value is possible. (However, during 2-axis addition or subtraction, only 1st or 2nd axis display is possible in B-axis display.) Restart Starts peak hold calculation. Operation is made by external input. Starts peak hold calculation of each axis. Operation is made by external input (for each axis). Hold function (latch and pause) Latch = display and output holding Pause = peak calculation holding Comparator function Input signal signal Comparator judgment output A set of upper and lower limits is settable. BCD output lower limits are settable. Switching of a set is made through BCD connector. Current value and peak value (max., min., and peak-to-peak values) can be output. input/output Reset Preset Master calibration function Key operation A set of upper and lower limits is settable. Provided A set of upper and lower limits is settable for each axis. However, single-axis setting cannot be made during addition or substation. Reset, start/latching, and pause of each axis RS-TRg input ( data output command) Comparator judgment output of each axis Four sets of upper and lower limits are settable for each axis. However, single-axis setting cannot be made during addition or substation. Switching of a set is made through BCD connector. NPN open collector output Each function can be activated using command instead of key operation. Current, max., min., and peakto-peak values can be output using data output command. Current value and peak value (max., min., and peak-to-peak values) can be output. Reset can be made by key operation or external reset input. Key operation or command via Reference point function Key lock function Power supply Key operation A set of upper and lower limits is settable for each axis. However, single-axis setting cannot be made during addition or substation. RS-TRg input ( data output command) Each function can be activated using command instead of key operation. Current, max., min., and peakto-peak values can be output using data output command. Key operation or command via 2. W 2.3 W 2.5 W Operating temperature range Storage temperature range Mass Approx. 2 g Approx. 23 g Approx. 22 g Approx. g Approx. 27 g Approx. 23 g Compatible measuring units Number of input axes Input resolution Number of display axes Display data Display resolution Direction Alarm display Addition and subtraction function Peak hold function Restart Hold function (latch and pause) Latch = display and output holding Pause = peak calculation holding Comparator function Positioning function Input signal signal Comparator judgment output BCD output LY71 1 axis or 2 axes (by parameter setting) Linear standard:.1 /.5 / 1/ 5 / 1 µm (expanded linear:.5 / 2 / 2 / / 5 / 1 µm), Angle: 1 s / 1 s / 1 min / 1 min, (Expanded angle: 1 degree) Current, max., min., and peak-to-peak values (= max. value min value) of each axis or current, max., min., and peak-to-peak values (= max. value min value) of 2-axis addition and subtraction Setting of axis to be displayed can be set by parameter. Data (current value, max. value, etc.) to be displayed can be switched by key operation. Measuring unit input resolution or more. It is possible to provide simple angle display by adhering Digiruler in arc. (There are limitations on displayable resolution depending on radius size.) Parameter-based polarity setting for each axis 2-axis addition and subtraction is possible, but axis-based calculation is impossible during addition or subtraction (addition and subtraction display is impossible during use of two LZ71-Bs). Peak calculation of each axis or addition or subtraction value can be made (calculation of each axis (single axis) cannot be made during addition or subtraction). Starts peak hold calculation of each axis/all axes. Operation is made by key operation or general external input. Latch function or pause function (selected by parameter setting) Operation: key operation or general external input Unavailable if comparator function is selected. (Comparator/positioning function is selected by parameter setting.) For general input, 3 items are selected from hold, restart, display switching (switching between current and peak values), and reference point loaded (datum value reproduction start). General output (2 items are selected from alarm, display data (current or peak value), reference-point passing, reference-point alarm, and zero-point passing.) Available only when LZ71-KR is used. Open collector (isolated from photocoupler and -24 V internal circuit) and relay (24 V DC/1 V AC at.3 A, ON time: approx. 2 ms, OFF time: approx. 1 ms) input/output A/B phase output Expansion unit Reset Preset Master calibration function Datum point/reference point function Key lock function Data storage Scaling function Liner compensation Power supply Operating temperature range Storage temperature range Mass Reset can be made by key operation or external reset input. A value can be set by key operation and a value set by external preset recall can be recalled. Provided Provided Provided (presence/absence of setting is set by parameter) Storage/no-storage can be set. Provided (±6 µm/m) Optional PSC-/22/23 adapter is used. 32 VA max. (when optional AC adapter is used) Approx. 1.5 kg 36 37

20 LY LY72 Technical information LT Series Usage Notes Compatible measuring units Number of input axes Input resolution LY72 1 axis, 2 axes, or 3 axes (by parameter setting) Linear standard:.1 /.5 / 1 / 5 / 1 µm (expanded linear:.5 / 2 / 2 / / 5 / 1 µm), Angle: 1 s / 1 s / 1 min / 1 min, (Expanded angle: 1 degree) Number of display axes 3 axes (A-, B-, and C-axis display) Display data Display resolution Direction Alarm display When axis label A, B, and C are selected Current, max., min., and peak-to-peak values (= max. value min value) of each axis Current value of each axis Measuring unit input resolution or more. It is possible to provide simple angle display by adhering Digiruler in arc. (There are limitations on displayable resolution depending on radius size.) Parameter-based polarity setting for each axis Addition and subtraction function Peak hold function Restart Hold function (latch and pause) Latch = display and output holding Pause = peak calculation holding Comparator function Positioning function Input signal signal Peak calculation of each axis is possible. Starts peak hold calculation of each axis/all axes. Operation is made by key operation or general external input. Operable using command in addition to those at the left None None None Only latch function is possible. Operation is made by key operation or general external input only (no command). External reset of each axis and general input (One of latch, reference point loaded, display switching, and preset recall is selected) External reset of each axis and general input (One of latch, reference-point load, and pre-set recall is selected) 1 for each axis (3 in total) General output (One of alarm, display data, reference-point passing, and reference-point alarm is selected.) Comparator judgment output BCD output input/output Each function can be activated using command instead of key operation. Current, max., min., and peak-to-peak values of each axis can be output using data output commands. A/B phase output Expansion unit Reset Preset Reset can be made by key operation or external reset input. General output (One of alarm, reference-point passing, and reference-point alarm is selected.) Current value of each axis can be output using data output command. Value is settable by key operation or using command. A value set by external preset recall can be recalled. Master calibration function Provided None Datum point/reference point function Key lock function Data storage Scaling function Linear correction Power supply Operating temperature range Storage temperature range Mass M4 Max. depth: (3.7) (1.5) 8 (9.5) Provided Provided (presence/absence of setting is set by parameter) Storage/no-storage can be set. Provided (±6 µm/m) Optional PSC-/22/23 adapter is used. 32 VA max. (when optional AC adapter is used) Approx. 1.5 kg M5 Max. depth: (31.5) 3 When mounting in a panel 2. Insert the display unit into the cut-out opening in the panel from the front. 3. Attach the supplied installation brackets (upper/lower) from the rear. Panel cutout diagram I/O connector The I/O connector on the rear panel of the counter unit has functions for Go/No-go output based on the comparator function, start input, pause input, trigger input, and reset input. < Connector pin assignment > I/O connector A Power input connector FG V V DC IN A Rear of counter unit Use a shielded cable for connection to the FG pin on the rear of the counter unit. (Prepare a shield cable by yourself.) Cross section of the cable B I/O connector B Common I/O connector Outer cover Knitted shield Connector used: MC1.5/7-ST-3.5 (provided) made by Phoenix Contact I/O connector (common) Pin No Signal name GND START(A) PAUSE (A) START(B) PAUSE (B) RS-TRG GND IN/OUT *1 Connection is prohibited for 1-channel model. *2 Connection is prohibited for models other than model. - IN IN IN IN IN - Description Start/latch input (A) Pause input (A) Start/latch input (B) *1 data output and trigger input *2 I/O connector description I/O connector A Pin No. Installing the LT1A/11A/3 counter unit Fig.1 Panel box Fig.2 Fig.3 LY71/72 panel mounting 4-R3 or less 262 ± Mount counter unit with screws from the back Pin No Signal name Installation brackets (supplied) GND NC RESET (A) LO (A) GO (A) HI (A) GND Signal name GND NC RESET (B) LO (B) GO (B) HI (B) GND IN/OUT IN OUT OUT OUT I/O connector B (not provided for 1-channel models) - IN/OUT - - IN OUT OUT OUT < Go/no-go judgment output > High: Display value > upper limit L (ON) Low: Lower limit > display value L (ON) Note: All go/no-go judgment outputs become H (OFF) if alarm occurs. - display unit Description Connection prohibited Reset input (A CH) Go/No-go output Low (A CH) Go/No-go output Go (A CH) Go/No-go output High (A CH) Description Connection prohibited Reset input (B CH) Go/No-go output Low (B CH) Go/No-go output Go (B CH) Go/No-go output High (B CH) <Start/latch input> If judgment output is L (ON), the max. and min. values are set to the current value (and peak-to-peak value is ), and new holding starts (start function). When initial settings are set to shipment settings, if the measuring mode is in current value mode, go/no-go judgment output (I/O connector) and display are held at L (ON) (latch function). Note: While judgment output is L (ON), reset/present value recall by reset key or using an external reset/preset value recall input signal becomes invalid. <Reset input> Measured value is set to if judgment output is L (ON). If a preset is made, a preset value is recalled. Note: Even if L (ON) is left as is, go/no-go judgment output (I/O connector) and display are not held. (3) ± Panel thickness: max. 3 Installation brackets (supplied) /inch 38 39

21 Carbide flat feeler Off-center feeler 13 1 : Width 1 or less 11 Coupling DZ-191 Mounting Magnetic feeler DZ-181 ( 9 22 Roller thickness

22 Compatibility Digital gauge Adapter/conversion cable Note 1: MT/13 is interpolator. s Interface unit Old counters External device Extension cables DK8A/B Series DK8S Series DK1//5/1/11/155/ Series CE29 Series Cable length:.3/1/3/5/1 m (Cable with bare wires) Unnecessary LT3 Series LH7/71/71A/72 LY71/72 MG2-DK MG41-NE/NC MG42 : connectable A/B reference point (Differential line receiver input) CE8-1(1 m) -3(5 m) -5(5 m) -1(1 m) -15(15 m) * Total cable length is 2 m or less. CK-T(1 m) -T13(3 m) -T14(5 m) -T15(1 m) -T16(15 m) CE27-1(1 m) -3(3 m) -5(5 m) -1(1 m) CE22-1(1 m) -3(3 m) -5(5 m) -1(1 m) CE26-1(1 m) -3(3 m) -5(5 m) -1(1 m) CE27-1(1 m) -3(3 m) -5(5 m) -1(1 m)(extension cable for CE26) SZ5-T1 LH7/71/71A/72 LY71/72 DG Series (with HA13) * with no B assigned LY51/52 Without extension cable Unnecessary LY1/11 LH2, etc. Unnecessary LT1A Series MG2-DT LT1 Series DT/32 Series MT-5/1 Note 1 LT2A Series LT2 Series MT13-5/1 Note 1 LT3 Series Unnecessary LT11A Series MG2-DT LT11 Series CE8-1(1 m) -3( m) -5(5 m) -1(1 m) -15(15 m) * Total cable length is 2 m or less. CK-T(1 m) -T13(3 m) -T14(5 m) -T15(1 m) -T16(15 m) DT5 Series MT13-1 Note 1 LT3 Series DK8 Series * s with no A/B assigned to model CE29 Series Cable length:.3/1/3/5/1 m (Cable with bare wires) Unnecessary LT3 Series MG2-DK LH7/71/71A/72 LY71/72 : connectable A/B reference point (Differential line receiver input) CE27-1(1 m) -3(3 m) -5(5 m) -1(1 m) * When CE8-1(1 m) -3(3 m) or CK-T(1 m) -T13(3 m) is used, the total cable length is 5 m or less. CE22-1(1m) -3(3 m) CE26-1(1 m) -3(3 m) CE27-1(1 m) -3(3 m) -5(5 m)(extension cable for CE26) DZ51 + SZ7-1 LH7/71/71A/72 LY71/72 DG-B Series Unnecessary LT2A Series MG2-DG LT2 Series Without extension cable DZ51 LY51/52 SZ7-2 LT3 Series DEBR/DE3BR SZ7-1 LH7/71/71A/72 LY71/72 Without extension cable Unnecessary LY51/52 DL31B/DLB/DL1BR/DL3BR/DL6BR Unnecessary LT2A Series MG2-DG LT2 Series DZ51 LH7/71/71A/72 LY71/72 LY51/52 Without extension cable (DL31B, B) Total cable length: 1 m or less 42 43

23 Technical Information Useful functions of counter units LT1A/LT11A/LT3 The combination of a high-accuracy digital gauge and an LT-series multifunction counter allows the following measurements to be made. The internal counter always holds current value, maximum value, minimum value, and peak-to-peak value irrespective of the measuring mode (current, maximum, minimum, and peak-to-peak values). Latch function The latch function holds output data and go/no-go judgment output with respect to its value in the current value mode. Datum [Latch conditions] Start input signal is set as latch input in parameter setting. Current value mode Note: This function does not work if the measuring mode is in peak-value mode. When to are traced in the current-value measuring mode, current value is displayed at position. Here (at position ), if the measuring mode is changed to the maximum value, indication becomes as in. In the same way, if the measuring mode is changed to minimum value, indication becomes as in and when it is set to peak-to-peak value, indication becomes as in -. In this way, the measuring mode is Latch ON Latch OFF Current value switched through the BCD terminal for models with BCD output or switched externally using command to display and output data. Datum-point reproduction function using a DK Series digital gauge and LT3 Series counter Up to now, even when master (datum point) calibration is made, the current position is reset if power supply is turned OFF. Thus, master (datum point) calibration needs to be made again using the master (datum point) at power ON. The DK Series Digital Gauges incorporate the reference point; once master (datum point) calibration is made, the counter can store data and reproduce the datum point without master (datum point) calibration in the reference-point referring function. First, a difference value between a digital gauge s built-in reference point and master (datum point) is measured to preset the master (datum point). If the master (datum point) is (zero), a difference value is preset to (zero). * The reference point is at the position where the spindle is pushed by 1 mm or more. When the counter s power supply is turned ON again, the counter starts up in the reference-point referring mode and display blinks in, causing the counter to enter reference-point detection waiting status. When the spindle is pushed and passes through the reference point, counting is made by the current value display from the master (datum point) position. (The counter stores internally a difference value between the master (datum point) and reference point in memory.) BCD output connector Using an LT Series as a multistage comparator For the LT Series counters, comparator settings are lower and upper limit settings as standard; no setting range can be increased. The LT Series BCD output specifications allow up to four sets of combinations of setting values (upper and lower limits) of the comparator to be registered. This allows an LT Series counter as a multistage comparator. Combining ON/OFF of pins 35 and 36 of the BCD output connector allows four ways (4 sets) of switching to be made. (Four sets of comparators can be set from 1st set (smallest range) to 4th set (largest range).) No. 35 pin No. 36 pin Upper and lower limits of comparator values H H Upper and lower limits of 1st set L H Upper and lower limits of 2nd set H L Upper and lower limits of 3rd set L L LED display Conditions High Go Low Measured data > upper limit Lower limit > measured data display display Count display blinking in After referencepoint detection (zero) setting by master calibration Higher than mater by 2 mm Count display blinking in (zero) setting by master calibration Higher than mater by 2 mm Combination (lower limit 1, upper limit 2) Combination (lower limit 1, upper limit 2) Combination (lower limit 2, upper limit 3) Combination (lower limit 2, upper limit 3) Combination (lower limit 3, upper limit 4) Combination (lower limit 3, upper limit 4) 2 Reference point Master (datum point) Workpiece 2 Reference point Workpiece Combination (lower limit 4, upper limit 5) Combination (lower limit 4, upper limit 5) Example 1: Case where the counter is used as a 6-stage comparator Example 2: Case where the counter is used as a 9-stage comparator In measurements where judgment output GO (OK) signal and In measurements where judgment output LO, GO, and HI signals and comparator combinations comparator combinations (4 sets) are observed in PLC I/O, four sets (4 sets) are observed in PLC I/O, if four sets of comparators are switched from the 1st set to the of comparators are switched from the 1st set to the 4th in turn and a 4th in turn and judgment output becomes high limit (HI), which judgment output (LO, GO, or HI) comparator for which judgment output becomes GO has an OK region. is produced in next combination is seen to determine which region applies. (If judgment output becomes GO in the 3rd set, the comparator (If judgment output becomes HI in the 2nd set and judgment output is LO in the 3rd set, an area concerned has the region of 3 mm or more to 4 mm inclusive.) of over 4 mm to 5 mm not inclusive applies.) 44 45

24 Safety No compromise for high-accuracy products M E M O QC1J39 Magnescale Co., Ltd. is registered to ISO 91 (Quality) Our products comply with CE Marking requirements, have acquired UL certifications and meet other regulations, ensuring safe use the world over. We have met: EMC Directives(CE) EMI: EN 5511 Group 1 Class A / 91 FCC Part 15 Subpart B Class A EMS: EN for Products with built-in AC power supply: for Products with Laser: Traceability Traceability Flow Chart (Length) International Committee for Weights National Primary Standards National Institute of Advanced Industrial Science and Technology (AIST) National standards Optical comb and Measures (CIPM) International Bureau of Weights and Measures (BIPM) Magnescale Corporation National Secondary Standards Iodine saturation absorption stabilized He-Ne laser at 6nm Manufacturing Reference Standard Stabilized He-Ne Laser (6nm) Products 46 47

Magnescale Co., Ltd. Digital Gauge General Catalog. Magnescale Co., Ltd.

Magnescale Co., Ltd. Digital Gauge General Catalog. Magnescale Co., Ltd. Digital Gauge General Catalog Magnescale Co., Ltd. Shinagawa Intercity Front 6F, 2-14-14, Konan, Minato-ku, Tokyo 18-7, Japan Headquarters International Sales Department Magnescale Americas Inc. Magnescale

More information

Magnescale Co., Ltd. Digital Gauge General Catalog. Magnescale Co., Ltd.

Magnescale Co., Ltd. Digital Gauge General Catalog. Magnescale Co., Ltd. Digital Gauge General Catalog Magnescale Co., Ltd. Headquarters International Sales Department Magnescale Americas Inc. Magnescale Europe GmbH Service & Parts http://www.magnescale.com : 4 Suzukawa, Isehara-shi,

More information

Digital Gauges and Interfaces for Data Collection and Analysis

Digital Gauges and Interfaces for Data Collection and Analysis Digital Gauges and Interfaces for Data Collection and Analysis Digital Gauges and Interfaces for data collection within multiple measuring fixtures The development of production measurement technology

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series 3 (For )/ 3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display Can be integrated with a vacuum unit, Series ZX Built-in

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings for Display of High-speed Addition and Subtraction Maximum operating speed 2kHz Used in industrial machinery, end-measuring devices, and the like, this electronic counter is exclusively for display. It

More information

RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP)

RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP) RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP) Main characteristics Absolute transducer Strokes from 50 to 4000 (RK-_- -N/S) Digital output RS422 Start/Stop (RK-_-

More information

Absolute Rotary Encoder E6C-N. Ordering Information. Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders

Absolute Rotary Encoder E6C-N. Ordering Information. Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders Absolute Rotary Encoder Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders No need to reset origin point at power-up IP50 certification Ideal for packaging, plastics,

More information

Multi-Axis Step Motor Controller

Multi-Axis Step Motor Controller INFORMATION Multi-Axis Step Motor Controller RoHS VSpeed tuning control *1 (3 Axes: 4 Axes: ) V Linear/circular interpolation Axis 2 Linear interpolation 50 40 30 20 10 Origin 0 Current position Target

More information

Mu-checker To support building the system with automatic measuring unit or dedicated gages

Mu-checker To support building the system with automatic measuring unit or dedicated gages 7 24 7 3.5 16 Mu-checker To support building the system with automatic measuring unit or dedicated gages SERIES 519 Mu-checker (Electronic micrometer) Probes (Lever head / Cartridge head) Lever heads Order

More information

Incremental Encoder with Hollow Shaft

Incremental Encoder with Hollow Shaft Incremental Encoder Type RI 36-H n miniature industry encoder for high number of pulses n short mounting length n easy mounting procedure n Application e.g.: - Motors - Machine tools - Packaging Machines

More information

2. Actuator B: Ball type P: Pin type F: Flat type

2. Actuator B: Ball type P: Pin type F: Flat type Contact Displacement Sensor Built-in Amplifier Ensures Ease of Use and Saves Wiring Effort. Sensor Operates with a Low Force in a Wide Range of Applications. H Works with a low operating force (30 gf)

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

Compact High Accuracy Magnescales SR27A-***AAZY. (SIEMENS DRIVE CLiQ Model) Exclusive Cables CH22 Series. Specifications. Magnescale Co., Ltd.

Compact High Accuracy Magnescales SR27A-***AAZY. (SIEMENS DRIVE CLiQ Model) Exclusive Cables CH22 Series. Specifications. Magnescale Co., Ltd. Compact High Accuracy Magnescales SR27A-***SAZY SR27A-***AAZY (SIEMENS DRIVE CLiQ Model) Exclusive Cables CH22 Series Specifications Magnescale Co., Ltd. - 1 - Content Page 1. Product overview... 3 1-1.

More information

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications 10/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 1105 High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1493 Sensor selection guide... P.1055~ General precautions...

More information

Linear Gages Pages 414, 415, 420 to 42. Counters and Displays Pages 416 to 419, 426 to 428, 430. Laser Hologage Pages 431, 432

Linear Gages Pages 414, 415, 420 to 42. Counters and Displays Pages 416 to 419, 426 to 428, 430. Laser Hologage Pages 431, 432 Linear Gages Sensorpak Page 412 Linear Gages Pages 414, 415, 420 to 42 Counters and Displays Pages 416 to 419, 426 to 428, 430 Laser Hologage Pages 431, 432 LITEMATIC Motorized low force high precision

More information

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution GI55, GI56 Features Encoder with solid shaft ø mm or ø6 mm Max. 6000 pulses per revolution Optical sensing method Clamping or synchro flange Industrial standard High rotation speed up to 000 rpm Optional

More information

Data Sheet MEM 22. Absolute Encoder Multiturn

Data Sheet MEM 22. Absolute Encoder Multiturn Absolute Encoder Multiturn Features Resolution: Singleturn: up to 16,384 (14 Bit) steps per revolution Multiturn: up to 16,777,216 (24 Bit) revolutions Interface: SSI (synchron serial interface) or BiSS

More information

MDrive Linear Actuator

MDrive Linear Actuator MDrive Linear Actuator Compact, integrated all-in-one linear motion systems MDrive 23 Plus Linear Actuator, Description MDrive Plus Linear Actuator Presentation The MDrive Plus Linear Actuator is an integrated

More information

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD To power supply Stepper Motor Driver LCD Electric Actuator Series LCC Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable T E M P O S O N I C S I I I INSTALLATION C A N B U S O U T P U T 550573 B W I R I N G - C A N b u s O U T P U T S CONNECTORS RG Connector Pin No. Wire Color Function 1 Gray CAN-L 2 Pink CAN-H 3 Yellow

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 1023 PHOTO PHOTO High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... F- Glossary of terms... P.1397 Sensor selection guide... P.967~ General

More information

GB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series

GB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series GB MIX COMUNICAZIONE MI Digital Electropneumatic Regulator Series N E W w w w. c a m o z z i. c o m Digital Electropneumatic Regulator Series Port G/ SPECIFICATIONS XXX SPECIFICATIONS XXX ITEM // X P X

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Programless Controller (With Stroke Study) How to Order

Programless Controller (With Stroke Study) How to Order Specialized for Series LEM Programless Controller (With Stroke Study) Series LECP RoHS P LE C P N Controller Compatible motor Step motor (Servo/ VDC) Number of step data (Points) stroke end points/ intermediate

More information

High Performance 2D Measurement System

High Performance 2D Measurement System Small Tool Instruments and Data Management High Performance 2D Measurement System Catalog No.E12012 World's best-in-class accuracy 2D measurement system A sophisticated height gage offering exceptional

More information

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing. 1105 PHOTO PHOTO High Speed High Accuracy Eddy Current Type Digital Sensor SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1493 Sensor selection guide... P.1055~ General

More information

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e The Sendix multiturn encoders 5862 and 5882, with SSI or RS485 interface and combined optical and magnetic sensor technology, offer a maximum resolution of 25 bits. These encoders are programmable via

More information

Absolute Encoder Multiturn

Absolute Encoder Multiturn Absolute Encoder Multiturn Features Resolution: Singleturn: up to 16,384 (14 Bit) steps per revolution Multiturn: up to 16,777,216 (24 Bit) revolutions Interface: SSI (synchron serial interface) or BiSS

More information

Terminal block 2 A 5 X 3. Specification

Terminal block 2 A 5 X 3. Specification D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables

More information

Electrostatic Potential Sensor

Electrostatic Potential Sensor Catalog No. BK-P044 Electrostatic Potential Sensor RoHS compliant product Introducing small sensors perfect for monitoring static electricity in-line! These sensors can constantly monitor and measure the

More information

MDrive Linear Actuator

MDrive Linear Actuator MDrive Linear Actuator Compact, integrated all-in-one linear motion systems MDrive 14 Plus Linear Actuator, Description MDrive Plus Linear Actuator Presentation The MDrive Plus Linear Actuator is an integrated

More information

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications 2/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with

More information

T E M P O S O N I C S I I I INSTALLATION

T E M P O S O N I C S I I I INSTALLATION T E M P O S O N I C S I I I INSTALLATION A N A L O G O U T P U T W I R I N G - A N A L O G O U T P U T S 550572 B CONNECTORS RG Connector: Pin No. Wire Color Function 1 Gray Output #1 (Displacement) *

More information

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-2- -N/E/S) Digital output

More information

Manual Clamps for Automotive Prototype Production

Manual Clamps for Automotive Prototype Production Manual Clamp interchangeable with 82M-6 This newest version provides more clamp arm variations and in addition two hold open devices. Opening angle can be reduced now. Page 15.2 New products 15.0 Notes

More information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information RM Series Modbus Digital Remote I/O Modbus Connector Type Digital Remote I/O Features Modbus RTU standard protocol Connects with sensor connector, e-con: saves wiring work (sensor connector, CNE Series,

More information

HG series Hand grip Hall effect joysticks

HG series Hand grip Hall effect joysticks Distinctive features and specifications Rugged, hand operation Hall effect sensing Sealed up to IP68 1 million life cycles Redundant outputs available Analog, USB and custom outputs CANbus J1939 and CANopen

More information

Piston rod cylinder Guide cylinders Series MSN. Brochure

Piston rod cylinder Guide cylinders Series MSN. Brochure Brochure 2 ini slide, narrow version Ø 6-6 mm double-acting with magnetic piston cushioning: elastic with integrated ball rail guide 3 overview overview 9 Sensors and sensor mountings, accessories Sensor,

More information

Effective range ABS AT505A ABS AT524 AT527

Effective range ABS AT505A ABS AT524 AT527 AT5XX-X Assembly Type ABS AT Series (Slim Spar Type) (Resolution 0.001µm/0.005µm/0.01µm) Features ABS AT500-S Series ABS AT5 5 - - Resolution 7: 0.001μm *only for AT52 5: 0.005μm (20μm/096) : 0.01μm *only

More information

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

Sensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52.

Sensor Accessories Retroreflectors and Retroreflective Tape Sensor Mounting Brackets Sensor Accessories. 52. Retroreflectors Sensor Accessory AC Sensor Tester/Demonstrator Pilot Device E65 Control Unit.1 Retroreflectors and Retroreflective Tape Product............................................. 414 Application..........................................

More information

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4 DTY-EPU....... DTY-EPS. q DTY-EPU.... DTY-EPS DTY-EPP-- PSU-BR q w ew r DTY-EPP-CC-L D ZDZD TrTr q r w e t y q w e r t y.. w e r 0-00 -- - -- 00--00 t URL http://www.koganei.co.jp y DTY-EPU Thank you very

More information

E3Z. The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly

E3Z. The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly Compact Photoelectric Sensor with Built-in Amplifier EZ The New Standard for Compact, Long-range Photoelectric Sensors Conserves Energy and Natural Resources, One Million Sold Yearly Long sensing distance

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

IK4A (with ONDA technology)

IK4A (with ONDA technology) IK4A (with ONDA technology) CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT) Main characteristics ONDA technology Optimized mechanical structure Strokes from 50 to 4000 Wide range

More information

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets 1135 Detector SERIES Related Information General terms and conditions... F-3 General precautions...p.1595 PHOTO PHOTO MEASURE From ultra-thin lead frames to iron sheets... Double feed detection of various

More information

ECI 1319 EQI 1331 EBI 1335 Absolute Rotary Encoders without Integral Bearing. Product Information

ECI 1319 EQI 1331 EBI 1335 Absolute Rotary Encoders without Integral Bearing. Product Information Product Information ECI 1319 EQI 1331 EBI 1335 Absolute Rotary Encoders without Integral Bearing Suited for safety-related applications up to SIL 3 when coupled with additional measures 09/2018 ECI 1319,

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH REMOTE ELECTRONICS (ANALOG OUTPUT) Main characteristics Absolute transducer with remote electronics structure Sensor available in three

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Safety-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Optical sensor

More information

Product Information ECI 1118 EQI 1130 ECI 1119 EQI Absolute Rotary Encoders without Integral Bearing

Product Information ECI 1118 EQI 1130 ECI 1119 EQI Absolute Rotary Encoders without Integral Bearing Product Information ECI EQI 0 ECI 9 EQI Absolute Rotary Encoders without Integral Bearing 0 ECIEQI 00 Absolute rotary encoders Synchro flange 0F) for axial mounting Blind hollow shaft A) Without integral

More information

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide Product Information LS 1679 Incremental Linear Encoder with Integrated Roller Guide April 2016 LS 1679 Incremental linear encoder for measuring steps to 5 µm or 1 µm Integrated wear-free roller guide with

More information

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

TOUCH SCREEN CONTROLLER for Air Conditioning Control System INSTALLATION MANUAL TOUCH SCREEN CONTROLLER for Air Conditioning Control System Model: BMS-TP064ACE BMS-TP064PWE BMS-TP52ACE BMS-TP52PWE Thank you very much for purchasing the TOSHIBA Touch Screen Controller.

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

HG series Hand grip Hall effect joysticks

HG series Hand grip Hall effect joysticks Distinctive features and specifications Rugged, hand operation Hall effect sensing Sealed up to IP68 1 million life cycles Redundant outputs available Analog, USB and custom outputs CANbus J1939 and CANopen

More information

RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD

RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD (ANALOG OR START/STOP OUTPUT) Main characteristics Absolute transducer Strokes from 50 to 4000mm (RK-4- -N/E/S) Digital output

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets

From ultra-thin lead frames to iron sheets... Double feed detection of various metal sheets 1147 Detector SERIES Related Information General terms and conditions... F-7 General precautions...p.151 PHOTO PHOTO MEASURE ITY From ultra-thin lead frames to iron sheets... Double feed detection of various

More information

ECI 4010 EBI 4010 Absolute Rotary Encoders with 90 mm Hollow shaft. Product Information

ECI 4010 EBI 4010 Absolute Rotary Encoders with 90 mm Hollow shaft. Product Information Product Information ECI 4010 EBI 4010 Absolute Rotary Encoders with 90 mm Hollow shaft Suited for Safety-Related Applications up to SIL 3 When Coupled with Additional Measures March 2017 ECI 4010, EBI

More information

MDrive Linear Actuator

MDrive Linear Actuator MDrive Linear Actuator Compact, integrated all-in-one linear motion systems Hybrid Linear Actuator, Description MDrive Hybrid Linear Actuator MDrive Hybrid Linear Actuator,, non-captive and external shaft

More information

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety Compact for High-Density Mounting with Easy Snap-In Connector H Connector features a built-in safety lock for shock and vibration resistance H replacement made simple without rewiring H Cables can be bent

More information

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR Built-in Power Supply Photoelectric Sensor CSM DS_E_12_3 Model Contribute to Overall Cost Reduction erminal Block Models Easy to wire and adjust. For the most recent information on models that have been

More information

EtherCAT Remote I/O Terminal GX series

EtherCAT Remote I/O Terminal GX series EtherCAT Remote I/O Terminal GX series Digital I/O Terminal 2-tier Terminal Block Type Digital I/O Terminal 3-tier Terminal Block Type Digital I/O Terminal e-con Connector Type Analog I/O Terminal 2-tier

More information

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend Solid State Relays with Failure Detection Function G3PC Refer to Warranty and Application Considerations (page 1), Safety Precautions (page 4), and Technical and Safety Information (page 6). Detects failures

More information

Inductive Cylinder Position Sensors

Inductive Cylinder Position Sensors Inductive Cylinder Position Sensors 4-Wire DC (NPN and PNP) 2-Wire AC/DC Weld immune 250, 000, and 3000 psi designs C-Series F-Series Rating (psi) Probe Diameter Inductive Cylinder Position Sensors Pepperl+Fuchs

More information

V-Anvil Micrometers SERIES 314, Flutes and 5 Flutes

V-Anvil Micrometers SERIES 314, Flutes and 5 Flutes V-Anvil Micrometers SERIES 314, 114 3 Flutes and 5 Flutes Measures the outside diameter of cutting tools (such as taps, reamers, end mills) which have three or five flutes. With Ratchet Stop for constant

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

H3CA-8H-AC/100/110/120

H3CA-8H-AC/100/110/120 Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat

More information

SENC 150 REFERENCE MANUAL

SENC 150 REFERENCE MANUAL SENC 50 REFERENCE MANUAL SENC 50 Table of Contents / Warnings Page Introduction / Supplied items... 4 2 Preparing the mounting / Mounting information... 5 3 Encoder dimensions... 8 4 Backup spar dimensions...

More information

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1. Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and

More information

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP Safety-Lock TM High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit proof Reverse polarity protection Reliable Increased ability

More information

RT300 Series Crane & Hoist Joystick. RunnTech. Potentiometer: ±32, Hall sensor: ±20

RT300 Series Crane & Hoist Joystick. RunnTech. Potentiometer: ±32, Hall sensor: ±20 Electronics (Changzhou) Corp. RT00 Series Crane & Hoist Joystick RT00 Series Crane & Hoist Joystick Product Features Single axis or dual axis control; Pure silver contacts to ensure durable; Spring return

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

HT series Ruggedized Hall effect joysticks

HT series Ruggedized Hall effect joysticks Distinctive features and specifications Rugged finger positioning control Available with CANbus J1939 Available with USB 1.1 HID compliant interface 1, 2 and 3 axis configurations 1 million life cycles

More information

Absolute encoders - SSI

Absolute encoders - SSI Features Encoder multiturn / SSI Optical sensing Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics Counting direction input Available

More information

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability 82 PHOTO PHOTO Compact Inductive Proximity Sensor -separated GA- SERIES General terms and conditions... F-7 Related Information Glossary of terms... P.86~ Sensor selection guide... P.757~ General precautions...

More information

The Original Green LED Incorporated Digital Micrometer

The Original Green LED Incorporated Digital Micrometer The Original Green LED Incorporated Digital Micrometer [New Larger Diameter Head LS-7070(M)] [New Advance Controller LS-7601] [New PC Based Software LS-H1W] High-speed, High-accuracy Digital Micrometer

More information

Rotary Position Technology Incremental Encoders

Rotary Position Technology Incremental Encoders -40 to 85 C IP Bearing-Lock High rotational speed Temperature High IP High shaft load capacity Shock/vibration resistant Magnetic field proof Short-circuit protected Reverse polarity protection Optical

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

YOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND

YOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND - YOUR STABLE PARTNER FOR MANUFACTURING. MARSTAND MarStand Indicator Stands, Comparator Stands and Run out Testing Instruments offer high stablity which ensures precise measurements; regardless of whether

More information

GV-EL124S Electric Strike

GV-EL124S Electric Strike GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either

More information

Incremental encoders Solid shaft with EURO flange B pulses per revolution

Incremental encoders Solid shaft with EURO flange B pulses per revolution Solid shaft with EURO flange B 0 5000 pulses per revolution EIL580 - EURO flange B - OptoPulse Features Size ø58 mm Precise optical sensing Output signal level TTL or HTL EURO flange B Connection axial,

More information

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER MAIN FEATURES Industry standard multiturn absolute encoder for factory automation applications. Optical sensor technology

More information

PRELIMINARY EAMH 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER ORDERING CODE BIT PARALLEL

PRELIMINARY EAMH 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER ORDERING CODE BIT PARALLEL EAMH 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER MAIN FEATURES Industry standard multiturn absolute encoder for factory automation applications. Optical sensor technology

More information

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30 Sensing distance Supply voltage Output 4 mm 8 mm 12 to 24 VDC 100 to 220 VAC 200 ma max. 100 ma max. Proximity Sensor Detects Objects without Being Influenced by Aluminum and Cast Iron Cut Chips Sense

More information

Performance and Value Optical Encoder System. Specifications. Benefits

Performance and Value Optical Encoder System. Specifications. Benefits Specifications Resolution Linearity Accuracy Cyclical Error Outputs Linear: 1µm, 0.5µm, 0.1µm, or 50nm Rotary: 163k to 3.27M CPR Tape Scale: ±5µm over 1m Linear Glass Scale: ±3µm over 1m Rotary Glass Scale:

More information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

Industrial Control Relays Relays and terminal module RS type

Industrial Control Relays Relays and terminal module RS type Relaysandterminal module Relays-and-terminal module RS, N A very compact, space-saving terminal module containing four or six relays with one NO contact. Features The RS series relays-and-terminal module

More information

FORMTRACER SV-C3100/4100 Series

FORMTRACER SV-C3100/4100 Series Form Measurement Surface Roughness/Contour Measuring System FORMTRACER SV-C3100/4100 Series Catalog No. E4304-525 Dual-purpose measurement and powerful analysis of surface roughness and contours combined

More information