PRICE LIST OF ACB SPARES

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "PRICE LIST OF ACB SPARES"

Transcription

1 s PRICE LIST OF ACB SPARES

2 SIEMENS INDUSTRY SECTOR TRAINING CENTER SITRAIN INDIA, KALWA. List of courses at SITRAIN-Kalwa & Authorized Training Centers (ATC) Sr. No. Title Days 1 PLC : SIMATIC S PLC : TIA Basic with SIMATIC S7-300 & Step7 8 3 PLC : TIA Advanced with SIMATIC S SIMATIC NET 5 5 SIMATIC WinCC 6 6 SIMATIC HMI Panels 3 7 DCS: SIMATIC PCS 7 Basic 8 8 DCS: SIMATIC PCS 7 Advanced 10 9 Basic course on AC/DC Drives 4 10 Basic AC-Drives with MM4 Maintenance 5 11 AC Drive: Masterdrives Vector Control 6 12 Masterdrives MC 6 13 SIMOTION D - System and Programming 8 14 SINAMICS S SINAMICS G130 / G Drives for Crane Control Application 5 17 DC Drive : SIMOREG DC Master 6RA LV Switchgear products & Maintenance 3 19 LV Power Distribution Systems 2 20 Electronic SOFT STARTER 2 21 Motor Management Systems (SIMOCODE) 2 22 PI - Basic Course 4 23 PI - Course (Pressure Instruments) 2 24 PI - Course (Flow Instruments) 2 25 PI - Course (Level Instruments) 2 26 PI - Course (Positioner Instruments) 2 27 Basic course on Industrial Electrical-Safety 3 28 Energy Management on Electrical Equipments 3 Note: (1) Courses 27/28 will be released after (2) All courses are available at Sitrain-Kalwa & ATCs also. (3) For MCMT-Courses details please contact Bangalore-Training center. Siemens Training Centres In India (Address & Contacts) All IA&DT Products Training Siemens-Sitrain Training Centre TSDC, Kalwa Works Thane Belapur Road, Thane Contact: Ms. Shweta Shah Tel.: / Sitrain-India, Kalwa All IA&DT Products Training Esskay Services Block No , B Wing Techno City Plot No. X-4/1 & X-4/2 TTC industrial Area, Mahape Navi Mumbai Contact: Ms. Sandhya Tel.: ATC-West Machine Tool Drives Trg, Bangalore Eklavya Learning Centre 2nd Floor, Du Parc Trinity (Nt to Big Kids Kemp) No. 17, M.G. Road, Bangalore Tel.: Contact: Ms. Vidya Jagdeesh MCMT-Training-South All IA&DT Products Training Karunya University Karunya Nagar Coimbatore Contact: Mr. Andre Aroume Tel.: ATC-South All IA&DT Products Training Industrial Automation Training Centre IATC, 178, Phase II Industrial Area, Panchkula Haryana (India) Tel.: Contact: Ms. Jyoti Bharti ATC-North Machine Tool Drives Training, Pune Esskay Training Centre Plot No. BG/SEI, 11-I Near Bhosari Telephone Echange MIDC, Bhosari, Pune Tel.: Contact: Surya Narayanrao, Ms Sandhya MCMT-Training-West All IA&DT Products Training Esskay Services G01, Matri Tower, Plot # 24, Block DN, Sector-5, Salt-Lake City, Kolkata Tel.: Contact: Soma Chakravorty ATC-East

3 s 3WL SPARES Note: 1. Prices mentioned in this folder is MRP (Maimum Retail Price, Prices are inclusive of all Taes) 2. The prices are subject to change without prior intimation 3. Ecise Gatepass will not be provided. w.e.f. 1 st December,2009. This Supercedes all previous Price Lists I IA BT LV CCR MRP- SGR/ 09-10

4 ET U 25 B NSE0_00983b Sr. No. Diagrams Description 1 Closing Solenoid/ Shunt Release 2 NSE01001 Under voltage release (Instantaneous) Price List for 3WL APPLICABLE FOR RATING Size I Size II Size III SPIRIDON MLFB V AC V DC NO. 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 4000A 5000A 6300A WL91110AD010AA WL91110AD020AA WL91110AD030AA WL91110AD040AA WL91110AD050AA WL91110AD060AA WL91110AE010AA WL91110AE020AA WL91110AE030AA WL91110AE040AA WL91110AE050AA WL91110AE060AA0 3 NSE01002 Under voltage release (Delayed) WL91110AE110AA WL91110AE120AA WL91110AE130AA WL91110AE140AA WL91110AF010AA0 4 Motorized operating mechanism WL91110AF020AA WL91110AF030AA WL91110AF040AA0 5 Door sealing frame \3WX36860JA00 6 Sealable cover & Locking device against reset trip indicator for ETU 15B ETU55B Sealable cover & Locking device against reset trip indicator for ETU 76B WL91110AT450AA WL91110AT460AA0 7 Castell lock mounting Kit (without lock) WL91110BA310AA0 For fied circuit breaker WL91110BB210AA0 Mutual mechanical interlocking with 2000mm Bowden wire For Guide frame WL91110BB220AA0 For withdrawable circuit breaker WL91110BB230AA0 8 NSE00989 Bowden wire For withdrawable circuit breaker with guide frame WL91110BB240AA0 2000mm (Version 2) WL91110BB450AA0 3000mm (Version 2) WL91110BB460AA0 4500mm (Version 2) WL91110BB470AA0 2000mm (Version 1) WL91110BB250AA0 3000mm (Version 1) WL91110BB260AA0 4500mm (Version 1) WL91110BB270AA0

5 Sr. No. Diagrams Description Price List for 3WL APPLICABLE FOR RATING Size I Size II Size III SPIRIDON MLFB V AC V DC NO. 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 4000A 5000A 6300A 9 Electrical ON Button (Push button+ wiring) WL91110AJ020AA0 10 Automatic reset of the re-closing lockout WL91110AK010AA0 11 Ready to Close signal switch WL91110AH010AA0 12 Signal Switch for 1st and 2nd auiliary release WL91110AH020AA0 13 N S E 0 _ b Tripped Signalling Switch for trip unit system carrier, Made of metal WL91110AH040AA0 14 Tripped Signalling Switch for trip unit system carrier, Made of plastic WL91110AH140AA0 15 Spring Charging Switch WL91110AH080AA0 16 Motor locking switch in operating panel WL91110AJ060AA0 17 Emergency OFF switch WL91110BA720AA0 NSE line display for ETU45B WL91110AT810AA0 N S E 0 _ Earth Fault Module (only for ETU45B) alarm & release WL91110AT530AA0 (only for ETU76B) alarm & release WL91110AT560AA0 NSE00978 Male Connectors for ACB WL91110AB010AA0 Sliding contact module for frame WL91110AB080AA0 20 Auiliary contacts Auiliary Supply connectors for ACB or Frame (Screw Connectin SIGUT) WL91110AB030AA0 NSE0_01586 Complete terminal assembly SIGUT Contact module + Plug) (Sliding WL91110AB180AA0

6 N S E 0 _ a PRO FIBUS DP Device CubicleBus NSE Sr. No. Diagrams Description Price List for 3WL APPLICABLE FOR RATING Size I Size II Size III SPIRIDON MLFB V AC V DC NO. 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 4000A 5000A 6300A Breaker Data Adapter WL91110AT280AA0 21 BDA Plus WL91110AT330AA0 Digital output module with rotary switch, relay output WL91110AT260AA0 Digital output module configurable, relay outputs WL91110AT200AA0 Digital input module WL91110AT270AA N S E 0 _ a Analogue output module WL91110AT230AA0 Short time grading control ZSI module WL91110AT210AA0 Digital output module with rotary switch, upto coupler outputs WL91110AT250AA0 Digital output module configurable, optocoupler outputs WL91110AT300AA0 Cubical Bus (COM 15/16 to DO/DI Module) READY-MADE CABLING 0.2m WL91110BC040AA0 READY-MADE CABLING 1m WL91110BC020AA0 READY-MADE CABLING 2m WL91110BC030AA0 230 V/100 V Class WL91110BB700AA0 24 Voltage Transformer V / 100V Class WL91110BB680AA0 25 Communication Module (COM 15Module) For Profibus Communication WL91110AT150AA0 (COM 16Module) For MOD bus Communication WL91111AT150AA0 26 Breaker Status Sensor WL91110AT160AA0 27 EMC Filter For Release WL91110AK320AA0 For Release WL91110AK340AA0 2NO+ 2NC WL91110AG010AA0 28 Auiliary Switch Block 2NO WL91110AG020AA0 1NO+1NC WL91110AG030AA0 1st block 3 micro-switches WL91110AH110AA0 29 Position Signaling Switch on chasis N S E 0 _ a 2nd block 6 micro-switches WL91110AH120AA0

7 Sr. No. Diagrams Description Price List for 3WL APPLICABLE FOR RATING Size I Size II Size III SPIRIDON MLFB V AC V DC NO. 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 4000A 5000A 6300A 30 Locking Device against opening of the cubicle door in ON condition (door defeat) Fied Version WL91110BB120AA0 Withdrawable Version WL91110BB130AA0 31 ETU Release-2 32 Release-2 With Metering function PLUS ETU15B LI WL93115AA000AA2 ETU25B LSI WL93125AA000AA2 ETU27B LSING WL93127AA000AA2 ETU45B LSIN (G) WL93145AA000AA2 ETU76B LSIN (G) WL93176AA000AA2 ETU45B LSIN (G) WL93145AA200AA2 ETU76B LSIN (G) WL93176AA200AA2 33 Software Switch ES for Sentron 3WL ACB & 3VL MCCB ZS23110CC100YA0 34 Metering function PLUS - For Release - 2 (Without Voltage Transformer) WL91110AT040AA0 35 Wiring Harness WL91128AJ240AA0 36 Front Facia WL91110AT500AA0 37 Charging Handle with Gear assembly WL91120AF000AA0 38 Mounting Plate for u/v, shunt closing coil ( plastic part only) Mounting Plate for Size I WL91128AC300AA0 Mounting Plate for Size II and Size III WL91128AC280AA0 39 n = A N S E 0 _ b Rating Plug Size I 250A WL91110AA510AA0 Size I 315A WL91110AA520AA0 Size I 400A WL91110AA530AA0 Size I 500A WL91110AA540AA0 Size I 630A WL91110AA550AA0 Size I 800A WL91110AA560AA0 Size I 1000A WL91110AA570AA0 Size I 1250A WL91110AA580AA0 Size I 1600A WL91110AA610AA0 Size II 2000A WL91110AA620AA0 Size II 2500A WL91110AA630AA0 Size II 3200A WL91110AA640AA0 Size II, III 4000A WL91110AA650AA0 Size III 5000A WL91110AA660AA0 Size III 6300A WL91110AA670AA0

8 Sr. No. Diagrams Description Price List for 3WL APPLICABLE FOR RATING Size I Size II Size III SPIRIDON MLFB V AC V DC NO. 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 4000A 5000A 6300A 40 WIRES X24 OF ETU76B TO X8.9 TO 8.12 WITHOUT NEUTRAL X24 OF ETU76B TO X8.9 TO 8.12 WITH NEUTRAL Conversion Kit, Internal Cable For Connecting Eternal N- And G-Transformer To X8 (W/O Male Connector) For Etu Release WL91110AK310AA WL91110AK300AA WL91110AK330AA0 41 LOCKING SET WL91110BA210AA0 NSE Operating Cycle counter (Mechanical) WL91110AH070AA0 43 ETU HAND HELD TEST KIT WL91110AT320AA0 44 Front facia ETU black cover WL91128AD180AA0 45 Safety Shutter for 3 Pole ACB Safety Shutter for 4 Pole ACB Size I WL91110AP040AA0 Size II WL91110AP060AA0 Size III WL91110AP070AA0 Size I WL91110AP080AA0 Size II WL91110AP110AA0 Size III WL91110AP120AA0 Size I WL91110AA110AA0 46 Internal current transformer (CT) for N- pole for old breakers Size II WL91110AA120AA0 N S E 0 _ a Size III WL91110AA130AA0 Size I WL91110AA210AA0 Eternal current transformer (CT) for N- pole Size II WL91110AA220AA0 47 N S E 0 _ a Eternal transformer for N- pole with copper connectors Size III WL91110AA230AA0 Size I WL91110AA310AA0 Size II WL91110AA320AA0 Size III WL91110AA330AA0 48 Conversion Kit ( Draw out / Racking mechanism) 3 Pole Conversion Kit ( Draw out / Racking mechanism) 4 Pole Size I WL91110BC110AA0 Size II WL91110BC120AA0 Size III WL91110BC130AA0 Size I WL91110BC140AA0 Size II WL91110BC150AA0 Size III WL91110BC160AA0

9 Sr. No. Diagrams Description 49 NSE NSE Arc Chute Cover for 3 pole ACB Arc Chute Cover for 4 pole ACB Pole Set (Maincontact set = 1 fied + 1 moving) 51 Lamination block Price List for 3WL APPLICABLE FOR RATING Size I Size II Size III SPIRIDON MLFB V AC V DC NO. 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 4000A 5000A 6300A Size I WL91110AS320AA0 Size II WL91110AS360AA0 Size III WL91110AS380AA0 Size I WL91110AS420AA0 Size II WL91110AS440AA0 Size III WL91110AS460AA0 Size I 1000A / 65KA WL91110AM500AA0 1600A / 65KA WL91110AM510AA0 2000A / 80KA WL91110AM520AA0 2000A / 100KA WL91110AM530AA0 Size II 2500A / 80KA WL91110AM540AA0 2500A / 100KA WL91110AM550AA0 3200A/ 4000A/ 80KA WL91110AM560AA0 3200A/ 4000A/ 100KA WL91110AM570AA0 Size III 4000A/ 5000A/ 100KA WL91110AM580AA0 6300A/ 100KA WL91110AM600AA0 Size I 630A to 1000A WL91128AG200AA0 1250A to 1600A WL91128AG210AA0 2000A WL91128AG220AA0 Size II 2500A WL91128AG230AA0 3200A/4000A WL91128AG240AA0 Size III 4000A/ 5000A/ 6300A WL91128AG250AA0 Size I 630A to 1000 A WL91110AN320AA A WL91110AN330AA0 52 Connecting terminal on chasis Horizontal connection Size II 2000 A WL91110AN340AA A WL91110AN350AA A WL91110AN360AA0 NSE Size III 4000A/ 5000 A WL91110AN370AA0 53 Connecting terminal on chasis vertical connection NSE RUCKWANDS Size I Size II 630A to 1000 A WL91110AN150AA A WL91110AN160AA A WL91110AN170AA A WL91110AN180AA A WL91110AN210AA0 4000A (6 Piece) WL91128AJ800AA0 4000A (8 Piece) WL91128AJ810AA0 4000/5000 A WL91110AN220AA0 Size III 6300 A (3 Piece) WL91110AN230AA A (4 Piece) WL91110AN100AA0 Size I- 3 pole 630A to 1600 A WL91128AF120AA0 Size I- 4 pole 630A to 1600 A WL91128AF150AA0 Size II- 3 pole 2000A / 2500A/ 3200A/ 4000A WL91128AF130AA0 Size II- 4 pole 2000A / 2500A/ 3200A/ 4000A WL91128AF160AA0 Size III Left Size III Centre 4000 / 5000/ 6300A Size III Right SIZE I 690V WL91110AS010AA0 55 Arc Chute SIZE II 690V WL91110AS020AA0 SIZE III, 690V WL91110AS030AA0

10 3WL1 Breaker MLFB Structure W L 1 N NN - N AA N N - N A A N Fied IEC Breaker Size BG1 BG2 BG Rating 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A ka (Ics) N S H ETU No ETU 15B 25B 45B 45B(disp) 55B 76B 27B(G) 45B(G) 45B(G/disp) 55B(G) 76B(G) AA BB CB EB FB JB NB DG EG FG JG NG Pole 3Pole 4Pole 3 4 Terminal & type HH HH F VV F FRS F FRD F HH DO VV DO FL DO Drawout breaker without frame Operating Mechanism Manual/other CC (110V) CC (230V) Mot+CC (230V) Mot+CC (110V) Mot+CC (24Vdc) st au rel Shunt rel No rel 24Vdc 30Vdc 48Vdc 60Vdc 110V 230V A B C D E F G 2nd au rel No rel Shunt rel 24Vdc 30Vdc 48Vdc 60Vdc 110V 230V u/v rel inst 24Vdc 30Vdc 48Vdc 60Vdc 110V 230V 415Vac u/v rel delay 48Vdc 110V 230V 415Vac A B C D E F G J K L U M N P Q R S T Au switch 2NO+2NC 4NO+4NC 6NO+2NC 5NO+3NC

11 "Z" Options For 3WL Breakers Fied Draw Out Special versions A V Version Rating Plug B B B B B B B B B B B B B B B Indication / Signals / Controls C01 5-digit mechanical operating cycle counter C10 Electrical ON pushbutton (pushbutton + wiring) C11 Electrical ON pushbutton (pushbutton + wiring) with sealing cap C12 Electrical ON pushbutton (pushbutton + wiring) with lock CES C13 Electrical ON pushbutton (pushbutton + wiring) with lock BKS C14 Electrical ON pushbutton (pushbutton + wiring) with lock IKON C20 stored-energy status indicator (Spring charge signaling switch) C22 Ready-to -close signaling switch (S20) C26 auiliary switch for the first auiliary release C27 auiliary switch for the second auiliary release Further options: trip unit/communication/measuring function F01 Breaker status sensor (BSS) connection F02 communication con with BSS+communication modul COM15 F12 communication con with BSS+communication modul COM16 F04 measuring function with voltage transformer; measured variables: U, I, P, W, f, cos F05 measuring function PLUS like F04 + harmonic distortion + harmonics Internal current transformer F23 internal current transformer for 4 pole Circuit-Breaker Frame size I, II & III Motorized operating mechanism and closing solenoid M01 motorized operating mechanism V DC M03 motorized operating mechanism V DC M05 motorized operating mechanism V AC / V DC M06 motorized operating mechanism V AC / V DC M21 closing solenoid 24 VDC(100%ED suitable for continuous operation) M22 closing solenoid 30 VDC(100%ED suitable for continuous operation) M23 closing solenoid 48 VDC(100%ED suitable for continuous operation) M24 closing solenoid 60 VDC(100%ED suitable for continuous operation) M25 closing solenoid VAC/ VDC(100% ED suitable for continuous operation) M26 closing solenoid VAC/ VDC(100% ED suitable for continuous operation) M31 closing solenoid 24 V DC ( 5% ED not suitable for continuous operation) M33 closing solenoid 48 V DC ( 5% ED not suitable for continuous M25 closing solenoid V AC / V DC ( 5% ED not suitable for continuous operation)

12 "Z" Options For 3WL Breakers M26 closing solenoid V AC / V DC (5% ED not suitable for continuous operation) Reclosing lockout and remote-reset K01 without reclosing lockout (e.g. automatic reset) K07 Tripped signaling switch, 1change-over contact Remote release (of the elektrical signal and indication) K10 remote reset solenoid 24 V DC K11 remote reset solenoid 48 V DC K12 remote reset solenoid 120 V AC / 125 V DC K13 remote reset solenoid V AC / 250 V DC Connection technik - withdrawable Circuit-Breaker with guide frames and guide frames (IEC: 4.digit=4, 12.digit=6 ) top bottom P00 Front single-hole Front single-hole P01 Front double-hole Front double-hole P08 Vertical Front single-hole P16 Front single-hole Horizontal P18 Vertical Horizontal P21 Front single-hole Vertical P23 Horizontal Vertical Additional equipment for guide frames R55 mutual mechanical interlocking for withdrawable kit *) R21 Shutter (lockable with padlocks) padlocks must be ordered separately Position signaling switch R15 Opt.1: connected 1 change-over contact; Test 1 change-over contact; R16 Opt.2: connected 2 change-over contact; Test 3 change-over contact; Locking device / interlocking R30 locking device against opening of the cubicle door in connected Additional equipment / locking device for Circuit-Breakers S01 locking device against unauthorized closing in the operator control S05 locking device against unauthorized closing in the operator control panel mounting set CASTELL S55 mutual mechanical interlocking for fied-mounted Circuit-Breaker (interlocking module with Bowden wire 2m) T40 Door sealing frames F40 ETU cover

13 3WL1 Guide Frame MLFB Structure W L N N A A N N - N A A 1 Fied Size Rating Pole Terminal Au. Plugs Type of connection BG1 BG2 BG A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A 3Pole 4Pole FRS FRD HH VV FL Without Without SIGUT Spring A B A B C D E Posn. Signaling Without switch 1, 1, 1 3, 2, Shutter Fied Without With A B (any frame size)

14 MLFB's of RETROFIT KIT Sr. No. SAP No. MLFB No. Product Rating Remark WL CA16 0AA0 3WE52 CDO to 3WL up to 1600 A With 1 hole cont WL CA17 0AA0 3WE4/5 SPDO to 3WL up to 1600 A With 2 hole cont WL CA17 0AA0 Z2 3WE4/5 SPDO to 3WL JOKA up to 1600 A WT CA18 0AA0 3WE4/5 SPDO to 3WT up to 1600 A With 2 hole cont WT CA18 0AA0 Z2 3WE4/5 SPDO to 3WT JOKA up to 1600 A WL CA19 0AA0 3WE68 SPDO to 3WL 2000 A WL CA20 0AA0 3WE72 SPDO to 3WL 3200 A WT CA21 0AA0 3WE58 SPDO to 3WL up to 1600 A 4 Pole Breaker WT CA22 0AA0 3WE68 SPDO to 3WT 2000 A WT CA23 0AA0 3WE72 SPDO to 3WT 3200 A WT91110CA240AA0 3WE4/5 CDO to 3WT up to 1600 A With 1 hole cont WL91110CA250AA0 CNCS to 3WL upto 1600A upto 1600A WL91110CA260AA0 CNCS to 3WL upto 3200A upto 3200A WT91110CA270AA0 CNCS to 3WT upto 1600A upto 1600A WT91110CA280AA0 CNCS to 3WT upto 3200A upto 3200A * Site needs to be visited before quoting for retrofit kits

15 s 3WT SPARES Note: 1. Prices mentioned in this folder is MRP (Maimum Retail Price, Prices are inclusive of all Taes) 2. The prices are subject to change without prior intimation 3. Ecise Gatepass will not be provided. w.e.f. 1 st December,2009. This Supercedes all previous Price Lists I IA BT LV CCR MRP- SGR/ 09-10

16 Price List For 3WT Sr. no. Diagram Description APPLICABLE FOR RATING SPIRIDON MLFB SIZE I SIZE II NO. V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A WT98511JB00 1 Shunt Release / Closing Coil WT98511JH00 2 Under Voltage release (Instantaneous) WT98511JK WT98531JB WT98531JH WT98531JK WT98531JM00 3 Under Voltage release (Delayed) WT98541JH WT98541JK WT98541JM WT98321JB00 4 Spring charging Motor WT98321JH WT98321JK00 5 Motorised operatiing mechanism consists of motor & closing solenoid Y1 110V WT98311JH00 220V WT98311JK00 6 NSE0_01586 Auiliary Connector Fied CB's WT98251JC00 Drawout CB'S WT98271JA00 7 Door Interlock Fied CB's WT98672JA00 Drawout CB'S* WT98671JC00

17 Price List For 3WT Sr. no. Diagram Description APPLICABLE FOR RATING SPIRIDON MLFB SIZE I SIZE II NO. V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 8 Auilliary switches 2CO WT98161CE00 9 Door Sealing frame Upto 3200A \3WX36860JA00 Mounting kit (without lock) WT98663JE00 Castell Lock key Type A \3WX3663-6JELA Castell Lock key Type B \3WX3663-6JELB 10 CASTELL LOCK Castell Lock key Type C \3WX3663-6JELC Castell Lock key Type D \3WX3663-6JELD Castell Lock key Type AB \3WX3663-6JEAB Castell Lock key Type AC \3WX3663-6JEAC 11 Mechanical Interlock kit for interlocking 2 breakers (1 Interlocking module + 2m Bowden wire) Fied breaker WT98663JA00 Drawout CB's WT98664JA00 12 For interlocking 3 ACB's additional bowden wire required for each ACB. 2meter wire WT98668JA00 3 meter wire WT98668JA01 4 meter wire WT98668JA Digit operating COUNTER upto 3200A WT98640CA00 14 Crank Handle Drawout CBs WT98840JA00

18 Sr. no. Diagram Description APPLICABLE FOR RATING SPIRIDON MLFB SIZE I SIZE II NO. V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 15 Locking device against unauthorised closing with safety lock (CES make) (instead of OFF push button) WT98631JA00 ETU 2WT WT98410JB00 16 ETU ETU 5WT WT98411JD00 NSE0_01610b ETU 8WT WT98410JC00 ETU35WT WT98414AA00 17 New version ETU ETU37WT WT98415AB00 ETU45WT WT98416AC00 ETU47WT WT98417AD00 18 FRONT FACIA SHUTTER FOR D/O BREAKER AUXILLIARY WIRES FOR FIXING AUX CONTACTS with Gold plated terminals PUSH BUTTON COVER ( TRANSPERENT) WT98631JK00 21 PUSH BUTTON ON PUSH BUTTON OFF FRONT FACIA Draw-out ACB's WT98770BA00 Fied ACB's WT98770CA00

19 Sr. no. Diagram Description APPLICABLE FOR RATING SPIRIDON MLFB SIZE I SIZE II NO. V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 24 POSITION SIGNALING SWITCH 6NO+6NC WT98841JC10 25 Mounting plate (Release housing) Plastic part for coil mounting Guide Frame Aluminium Rails 1 set (Left & Right) Uponinquiry 27 OLD 3WT / 3WN Hand Held Test Kit WT98475JA01 28 NEW 3WT Hand Held Test Kit WL91110AT320AA0

20 Sr. no. 29 Diagram Description SAFETY SHUTTERS FOR GUIDE FRAMES/ CHASIS APPLICABLE FOR RATING SPIRIDON MLFB SIZE I SIZE II NO. V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 630A/800A/1000A/1250A 1600A 3 pole size I WT98843CA A/2500A/3200A 3 pole size II WT98843DA00 630A/800A/1000A/1250A 1600A 4 pole size I WT98843CB A/2500A/3200A 4 pole size II WT98843DB00 630A/800A/1000A/1250A 1 piece size WT98233AA A 1 piece size upon inquiry 3WT98233BA00 30 Rear Vertical connection for guide frame/ chasis 2000/2500A 3Pole 3 Pieces upon inquiry 3WT98234AB /2500A 4Pole 4 Pieces upon inquiry 3WT98234AC A 3Pole 3 Pieces upon inquiry 3WT98234BB A 4Pole 4 Pieces upon inquiry 3WT98234BC00 630A/800A/1000A/ 1250A size I WT98210AA10 31 Main pole contact set for 3 pole & 4 pole (1FIXED+ 1MOVING) 1600A size I WT98210BA /2500A size II WT98210DA00 NSE A size II WT98210FA00 630A WT98422CD00 32 Internal Current transformers for main pole 3 pole & 4 pole breaker 800A WT98422CE A WT98422CF A WT98422CG A WT98422CH A WT98422FJ A WT98422FK A WT98422FM00 Upto 1600A size I WT98431RE00 33 Internal Current transformers for main pole & N pole FOR NEW VERSION 3WT ACB Upto 3200A size II WT98432RE00 N S E 0 _ a

21 Sr. no. Diagram Description APPLICABLE FOR RATING SPIRIDON MLFB SIZE I SIZE II NO. V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 630A WT98431CD00 800A WT98431CE00 34 Eternal Current Transformer for N - conductor for 3Pole & 4 Pole circuit breakers 1000A WT98431CF A WT98431CG A WT98431CH A WT98431FJ A WT98431FK A WT98431FM00 35 Eternal Current Transformer for N - conductor FOR NEW VERSION 3WT ACB Upto 1600A size I WL91110AA210AA0 Upto 3200A size II WL91110AA220AA0 N S E 0 _ a 36 Eternal Current Transformer for N - conductor with copper connectors FOR NEW VERSION 3WT ACB Upto 1600A size I WL91110AA310AA0 Upto 3200A size II WL91110AA320AA0 N S E 0 _ a 37 Conversion Kit ( Draw out / Racking mechanism) 38 Lamination Block/ Jaw Contact Size I WT98880GA00 For 3 Pole Size II WT98880KA00 Size I WT98880HA00 For 4 Pole Size II WT98880LA00 up to 1250A Size I A Size I A A Size II A Size II Arc Chute A Size I WT98110CA A Size II WT98110FA00

22 3WT MLFB SPLIT RATING FRAMESIZE ETU CC,MOTOR 9th Digit SHUNT,UVR 10th F1/F3/F8 SHUNT F2 11th Digit 04:400A 0:Ⅰ/3P ECO 4: No ETU A: Manual A: w/o 1st au rel 0: w/o 2nd au rel 06:630A 1:Ⅰ/3P 5:ETU 35WT B: Y1-DC24V B: F1-DC24V 1: F2-DC24V 08:800A 2:Ⅱ/3P 6:ETU 37WT E: Y1-DC110V/AC110V F: F1-DC/AC110V 2: F2-DC/AC110V 10:1000A 4:Ⅰ/4P ECO 7:ETU45WT F: Y1-DC220V/AC220V G: F1-DC/AC220V 3: F2-DC/AC220V 12:1250A 5:Ⅰ/4P 8:ETU 47WT G: Y1-DC24V+M24V H: F3-DC24V 4: w/o 2nd au rel+2co 16:1600A 6:Ⅱ/4P H: Y1-DC48V+M48V M: F3-DC/AC110V 5: F2-DC24V+2CO 20:2000A K: Y1-DC/AC110V+M110V N: F3-DC/AC220V 6: F2-DC/AC110V+2CO 25:2500A 32:3200A 40:4000A U: Y1-DC/AC220V+M220V P: F3-DC/AC380V U: F8-DC/AC110V V: F8-DC/AC220V W: F8-DC/AC380V 7: F2-DC/AC220V+2CO Note : For 12th digit =6 Rating 40: 3800A 3WT8081-0AA00-0AA2 1:CHINESE MAIN TERMINALS 2:English 0:Fied incl. Door sealing 2: Fied VV 0AA:No Accessories 5AA;No Accessories 3:DO w/o GF 0AB: CES lock 5AB: shutter+sealing cap 4:DO HH 0AC: mut mech int lock+sealing cap 5AC: mut mech int lock+sealing cap 8:DO HV 0AD: CES lock+mut mech int lock 5AD: shutter+mut mech int lock+sealing cap 6:DO VV 0AE: mut mech int lock+sealing cap+door int lock 5AE: CES lock 7:DO VH 0AF: CES lock+mut mech int lock+door int lock 5AF: CES lock+shutter 0AG: CASTELL lock+sealing cap 5AG: CES lock+mut mech int lock+door int lock X X AH: mut mech lock+sealing cap+door lock+castel+counter 5AH: S01+R20+S53+door int lock Y1 (CC) F2 (SHUNT) F1-F3-F8 0AJ: mut mech lock+sealing cap+counter 5AJ: CASTELL lock+sealing cap (SHUNT, 0AK: mut mech lock+sealing cap++door int lock+counter 5AK: shutter+castell lock+sealing cap UVR) 0AL: CASTELL lock+sealing cap+counter 5AL: mut mech lock+castell+sealing cap+door lock F1 X AM: mut mech lock+ces lock+door lock+castel+counter 5AM:Shutter+mut lock+castell+sealing cop+door lock F3 X AN:counter 5AP:shutter+sealing cap+counter F8 X2 1-2 delay (short X1-1 & X2-3) 0AP:door intlck 5AQ:mut int lock+sealing cap+door lock+counter 5AR:Shuter+mut intlock+seling cop+dor lock+counter Motor X AY:shuter+sealing cap+dor intlck+castel+pos sig sw 5AS:castell lock+sealing cop+counter 5BA:shuter+sealing cap+dor intlck+counter+pos sig sw 5AT:Shutter+castell lock+sealing cop+counter 5BB:shuter+sealing cap+dor intlck+counter+castel+pos sig sw 5AU:mut intlock+castell+seling cop+dor lock+counter 5BC:Shuter+sealing cap+door intlck+pos sig sw 5AV:Shuter+mut intlock+castel+seling cop+dor intlck+counter

23 3WT Guide Frame MLFB

24

25

26 s 3WN6 SPARES Note: 1. Prices mentioned in this folder is MRP (Maimum Retail Price, Prices are inclusive of all Taes) 2. The prices are subject to change without prior intimation 3. Ecise Gatepass will not be provided. w.e.f. 1 st December,2009. This Supercedes all previous Price Lists I IA BT LV CCR MRP- SGR/ 09-10

27 Sr. no. Diagram Description 1 Shunt Release / Closing Coil 2 UV Coil 3 Spring charging Motor Prices of 3WN6 Spares APPLICABLE FOR RATING SIZE I SIZE II SPIRIDON NO. MLFB MRP V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A WX36511JB00 Upon Inquiry WX36511JE00 Upon Inquiry WX36511JF00 Upon Inquiry WX36511JG00 Upon Inquiry WX36511JH00 Upon Inquiry WX36511JK00 Upon Inquiry WX36531JB00 Upon Inquiry WX36531JE00 Upon Inquiry WX36531JF00 Upon Inquiry WX36531JG00 Upon Inquiry WX36531JH00 Upon Inquiry WX36531JK00 Upon Inquiry WX36531JM00 Upon Inquiry WX36321JB00 Upon Inquiry WX36321JF00 Upon Inquiry WX36321JG00 Upon Inquiry WX36321JH00 Upon Inquiry WX36321JK00 Upon Inquiry 4 NSE0_01586 Auiliary connector Fied CB WX36251JC00 Upon Inquiry Drawout CB WX36271JA00 Upon Inquiry 5 CASTELL LOCK Mounting kit (without lock) WX36636JE00 Upon Inquiry Castell Lock key Type A \3WX3663-6JELA Upon Inquiry Castell Lock key Type B \3WX3663-6JELB Upon Inquiry Castell Lock key Type C \3WX3663-6JELC Upon Inquiry Castell Lock key Type D \3WX3663-6JELD Upon Inquiry Castell Lock key Type AB \3WX3663-6JEAB Upon Inquiry Castell Lock key Type AC \3WX3663-6JEAC Upon Inquiry 6 Crank Handle WX36840JA00 Upon Inquiry Upon Inquiry 7 Auiliary Contacts 2CO ( Change Over ) WX36161CE00 Upon Inquiry 2 X 2NO WX36161CA00 Upon Inquiry Guide Frame Aluminium Rails 8 Left & right side 1 set Uponinquiry Upon Inquiry

28 Sr. no. Diagram Description Prices of 3WN6 Spares APPLICABLE FOR RATING SIZE I SIZE II SPIRIDON NO. MLFB MRP V AC V DC 630A 800A 1000A 1250A 1600A 2000A 2500A 3200A 9 Mounting plate (Release housing) Upon Inquiry Upon Inquiry 10 SAFETY SHUTTERS FOR GUIDE FRAMES/ CHASIS 630A/800A/1000A/125 0A 1600A 3 pole size I WX36843CA00 Upon Inquiry 2000A/2500A/3200A 3 pole size II WX36843DA00 Upon Inquiry 630A/800A/1000A/125 0A 1600A 4 pole size I WX36843CB00 Upon Inquiry 2000A/2500A/3200A 4 pole size II WX36843DB00 Upon Inquiry 11 Conversion Kit ( Draw out / Racking mechanism) For 3 Pole For 4 Pole Size I WX36880GA00 Upon Inquiry Size II WX36880KA00 Upon Inquiry Size I WX36880HA00 Upon Inquiry Size II WX36880LA00 Upon Inquiry 630A/800A/ 1000A size I WY36210AA10 Upon Inquiry 12 Main contact set ( 1 Moving + 1 Fied ) 1250A/1600A size I WY36210BA00 Upon Inquiry 2000A Size II WY36210DA00 Upon Inquiry 2500A Size II WY36210EA00 Upon Inquiry NSE A Size II WY36210FA00 Upon Inquiry 13 Internal Current transformers for main pole 3 pole & 4 pole breaker 315A size I WX36422CA00 Upon Inquiry 400A size I WX36422CB00 Upon Inquiry 500A size I WX36422CC00 Upon Inquiry 630A size I WX36422CD00 Upon Inquiry 800A size I WX36422CE00 Upon Inquiry 1000A size I WX36422CF00 Upon Inquiry 1250A size I WX36422CG00 Upon Inquiry 1600A size I WX36422CH00 Upon Inquiry 2000A Size II WX36422FJ00 Upon Inquiry 2500A Size II WX36422FK00 Upon Inquiry 3200A Size II WX36422FM00 Upon Inquiry 14 SWITCH SHAFT (MAIN SHAFT) upto 1600A NA Upon Inquiry

29

30

Air Circuit Breakers. 1/2 Introduction

Air Circuit Breakers. 1/2 Introduction /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers /5 Introduction Up to 6300 A (AC), IEC /6 Introduction /9 General data /6 3-pole, fixed-mounted versions /23 3-pole, withdrawable

More information

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

Siemens AG Air Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens. Siemens AG Air Circuit Breakers Totally Integrated Power SENTRON Configuration Manual Edition / siemens.com/lowvoltage Siemens AG Siemens AG WL Air Circuit Breakers Introduction WL air circuit breakers/

More information

NW08 to NW63 fixed circuit breakers Circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b

More information

The Intelligent Simplicity. Sentron 3WL Air Circuit Breaker. Answers for industry.

The Intelligent Simplicity. Sentron 3WL Air Circuit Breaker. Answers for industry. The Intelligent Simplicity Sentron 3WL Air Circuit Breaker Answers for industry. SENTRON - Intelligent Simplicity In essence, modularity means: User-friendly ease of planning, multiple use of standard

More information

Description. Installation. Power supply

Description. Installation. Power supply Air circuit breakers Special versions Series MEGT07 0V/500V/DC 50 up to 5000 A The air circuit breakers MEGT07 are suitable for use as disconnecting switch in DC distributions up to a rated voltage of

More information

The Intelligent simplicity. sentron WL

The Intelligent simplicity. sentron WL Datasheet The Intelligent simplicity sentron WL s Unlimited Possibilities Tangram Tangram is an ancient Chinese game based on seven basic shapes. Tangram, an ancient game: The shapes are always the samethe

More information

Power Management System. Measuring Devices for Power Distribution

Power Management System. Measuring Devices for Power Distribution Power Management System Measuring Devices for Power Distribution Power Management System System overview /2 - Overview /2 - More information SENTRON Power Monitoring Devices General data /3 - Overview

More information

SENTRON 3VL Molded Case Circuit Breakers

SENTRON 3VL Molded Case Circuit Breakers Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload

More information

sirius Switching. Protecting. Starting. SIRIUS Product Overview

sirius Switching. Protecting. Starting. SIRIUS Product Overview sirius Switching. Protecting. Starting. SIRIUS Product Overview S00 Design Direct-on-line starting Reversing duty Assembly kit for busbar mounting 0 mm: RA9 -C 0 mm: RA9 -D Consisting of: wiring kit busbar

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Power Management System. Multifunction Measuring Instruments

Power Management System. Multifunction Measuring Instruments Power Management System Multifunction Measuring Instruments Power Management System /2 - System overview /2 - More information PAC3200 Multifunction Measuring Instruments /3 - Overview /4 - Benefits /5

More information

System-based switching, protecting, starting. SIRIUS Modular System. sirius

System-based switching, protecting, starting. SIRIUS Modular System. sirius System-based switching, protecting, starting. Modular System. sirius Everything for the electrical cabinet: Modular System. Contents S00 structure S00 selection and ordering data: Circuit breakers, contactors,

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

IZMX Series Air Circuit Breakers. Small, flexible, efficient

IZMX Series Air Circuit Breakers. Small, flexible, efficient IZMX Series Air Circuit Breakers Small, flexible, efficient Versatile circuit breakers up to 4000 A for cost-effective, optimized solutions. The IZMX16 of the NRX series is the smallest air circuitbreaker

More information

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection

More information

SIRIUS Motor Management and Control Devices

SIRIUS Motor Management and Control Devices Overview is a flexible, modular motor management system for motors with constant speeds in the low-voltage performance range. It optimizes the connection between the control system and motor starter, increases

More information

SIMATIC S plus TIA Portal

SIMATIC S plus TIA Portal Product range overview SIMATIC S7-1500 plus TIA Portal Power + Efficiency The ultimate plus in automation Intuitive, efficient, proven TIA Portal redefines engineering Answers for industry. Your plus of

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

QUICK REFERENCE PRICE GUIDE JUNE 2016

QUICK REFERENCE PRICE GUIDE JUNE 2016 QUICK REFERENCE PRICE GUIDE JUNE 2016 OUR CUSTOMER CARE COMMITMENTS Quality is Guaranteed All products supplied from this Quick Price Guide carry a guarantee against defects in materials and workmanship

More information

Fast Bus Fast Bus Busbar System

Fast Bus Fast Bus Busbar System Fast Bus Busbar System Contents Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V/AC24..230V (6ES7138-4CB11-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 04/2007

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. 3WL/3VL circuit breakers with communication capability - SENTRON Protection devices 3WL/3VL circuit breakers with communication capability - PROFIBUS System Manual PROFIBUS Introduction and overview 1

More information

OCR alarm (AL) (standard) When it happen to trip by over current, ground fault ( GFR ) and Earth leakage ( ER ), it issue a warning alarm.

OCR alarm (AL) (standard) When it happen to trip by over current, ground fault ( GFR ) and Earth leakage ( ER ), it issue a warning alarm. A Power supply module This module provides control source for DISPLAY module,trip indicator and several indicators (LEDs). (Even when the control power source is off, the function of over current protection

More information

VIP 40/45 VIP 400/410

VIP 40/45 VIP 400/410 40/45 400/410 Selection guide 01 PM100573 40/45 PM100576 400/410 self-powered integrated protection relay Optimised performance for transformer, incomer, feeder and bus riser protection Complete engineered

More information

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB Universal Motor Controller UMC-FBP Excellent motor protection and control ATEX ABB FieldBusPlug: the concept ABB s communicative product family comprises a wide range of switching, controlling and automation

More information

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3 Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State

More information

7KT/7KM PAC Measuring Devices

7KT/7KM PAC Measuring Devices s SENTRON 7KT/ A device to suit every requirement Fully informed at all times thanks to intelligent measuring technology The 7KT/7KM PAC measuring devices ensure precise and reliable measurement of power

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;

More information

The art of simplicity. sentron

The art of simplicity. sentron The art of simplicity Data Sheet sentron 3WT s Sentron 3WT The Art of Simplicity. During the last decade, with the introduction of 3WN and 3WL Circuit Breakers, Siemens introduced a new perspective in

More information

SIMATIC S Central processing units

SIMATIC S Central processing units SIMATIC S7-1500 Siemens AG 2013 Overview CPU 1511-1 PN PROFINET IO Controller for operating distributed I/O on PROFINET PROFINET I-Device for connecting the CPU as an intelligent PROFINET device under

More information

SIRIUS modular system

SIRIUS modular system SIRIUS modular system Switching, protecting, starting and monitoring with the highly flexible modular system siemens.com/sirius Everything for the control cabinet: the SIRIUS modular system. Press shop

More information

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles

Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting capability in cubicles Page Revision: - Issued: December 00 Data subject to change without notice )HDWXUHV 0RXQWLQJNLWV 0RXQWLQJNLWV Mounting kits for space-saving mounting in racks and cubicles and on walls IP54 protected mounting

More information

EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability.

EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability. GE Energy Management EntelliGuard* G Circuit Breakers Don t compromise arc flash protection for system reliability. The next chapter in the history of low-voltage circuit breakers EntelliGuard* G circuit

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Securing your power supply

Securing your power supply Securing your power supply Change-over Enclosed automatic and transfer switches for for critical Critical power Power applications applications Power and productivity for a better world TM Enclosed automatic

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

Pushbutton Units and Indicator Lights

Pushbutton Units and Indicator Lights SIGNUM 3S3 Introduction Overview SIGNUM is a range of plastic and metal control devices for frontplate mounting and rear wire connection. SIGNUM is of modern industrial design with a very construction

More information

Busbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A

Busbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A Siemens AG 20 Busbar Systems /2 Introduction /3 General data 40 mm Busbar Systems /6 Introduction /7 Base assemblies up to 400 A mm Busbar Systems /8 Introduction /9 Base assemblies up to 630 A /13 Base

More information

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry. For Efficiency and Reliability in the Control Cabinet The SIRIUS 3RA6 Compact Starter SIRIUS Answers for industry. Highlights Space savings in the control cabinet, thanks to compact design Minimized engineering,

More information

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK

SDR recloser. A PH Fault B PH Fault C PH Fault. Ground Fault. SGF Lockout Aux Power OK. Recloser OK SDR recloser A PH Fault B PH Fault C PH Fault Ground Fault SGF Lockout Aux Power OK Recloser OK Open Close Reclose ON Hot Line Tag ON All Protn OFF Inst Protn OFF Ground Fault Protn OFF SGF Protn OFF Trip

More information

Distributor, universal

Distributor, universal Distributor, universal Distributor, universal Product range overview Function Version Version Type Connection technology Protection class T-distributor Round plug M12 3-pin NEDU-L2R1-V8-M12G5-M12G5 1x

More information

SENTRON communication manual. sentron. User manual for communication capable SENTRON WL and VL circuit breaker '5$)7

SENTRON communication manual. sentron. User manual for communication capable SENTRON WL and VL circuit breaker '5$)7 SENTRON communication manual sentron Draft 10/29/02 User manual for communication capable SENTRON WL and VL circuit breaker s Introduction and Overview 1 SENTRON WL 2 SENTRON VL 3 PROFIBUS Profile SENTRON

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

WMS SUPPLEMENTARY PROTECTORS

WMS SUPPLEMENTARY PROTECTORS WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077

More information

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties. Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 06/2010

More information

Limit Switches and Safety

Limit Switches and Safety Limit Switches and Safety Introduction Contents Pages 3SE International (IEC) Limit Switches 3SE5 General data Overview......................................... 13/4-13/9 3SE5 plastic enclosures 3SE5,

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Support Packages for TIA Portal V14 February 2018 https://support.industry.siemens.com/cs/ww/en/view/72341852 Siemens Industry Online Support This entry is from the Siemens Industry Online Support. The

More information

Air Circuit Breaker (ACB)

Air Circuit Breaker (ACB) MPACT Air Circuit Breaker (ACB) Rated from 0 to 000A the MPACT circuit breaker has been designed to meet the most stringent demands in fault detection and safe interruption thereof. Available in frame

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: This is to certify that representative samples of SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY MOTOR CONTROLLERS, MANUAL (See following page for additional information.)

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

Components for Distribution Systems

Components for Distribution Systems Components for Distribution Systems /2 Introduction Busbar adapter systems /4 General data /7 40 mm system / 60 mm system /12 Accessories /14 Project planning aids Door-coupling rotary mechanisms /23 General

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN

SPAREPARTSCATALOG: CONNECTORS SPARE CONNECTORS KTM ART.-NR.: 3CM EN SPAREPARTSCATALOG: CONNECTORS ART.-NR.: 3CM3208201EN CONTENT SPARE CONNECTORS AA-AN SPARE CONNECTORS AO-BC SPARE CONNECTORS BD-BQ SPARE CONNECTORS BR-CD 3 4 5 6 SPARE CONNECTORS CE-CR SPARE CONNECTORS

More information

Siemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities.

Siemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities. Busbar Systems SENTRON Configuration Manual Edition 2014 Answers for infrastructure and cities. Busbar Systems 2 Introduction 3 General data 8US 40 mm busbar systems 7 Introduction 8 Basic assemblies

More information

Universal Motor Controller UMC22-FBP. High-grade Motor Protection and Control

Universal Motor Controller UMC22-FBP. High-grade Motor Protection and Control Universal otor Controller UC-FBP High-grade otor Protection and Control The FieldBusPlug concept This new ABB product family is a communication device range with switching and automation components which

More information

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs .3 Features and Benefits Saves installation time and cost One part number to order; no need to worry that any part has been left out Pick the meter or meters you need as it is designed to fit various Eaton

More information

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls SIRIUS Modular System. The perfect combination Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls Everything for the control cabinet: the SIRIUS

More information

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards) ////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 04/2007 A5E01119980-01

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

CDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA

CDW7. Standard: IEC Application. Standard and certification. International standard: IEC Approved certification: CB, CE, KEMA Application Applied to power distribution of AC Hz/60Hz, rated operational voltage 400/ 690V, rated current 200A~6300A and lower For power distribution and protecting circuit and power supply equipment

More information

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module INTEGRUS en Installation and User Instructions Integrus Language Distribution System LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker LBB 3422/20 Integrus Audio Input and Interpreters Module INTEGRUS

More information

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied. AG090115 How to configure SIMATIC STEP7 V5.5 to read cyclic data from Objective: To use Siemens SIMATC S7300 PLC to read data from MultiRanger/HydroRanger 200 HMI through SmartLinx PROFIBUS communication

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

4/0 EASY control relay

4/0 EASY control relay 4/0 DEL ALT ESC OK Contents 4/1 Page System overview 4/2 4/4 EASY800 networking 4/4 4/5 Basic units 4/5 Expansion units 4/9 Multi-function display 4/8 Display/operator unit 4/8 Power supply/cpu modules

More information

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay

Siemens AG UG46 PLC. 1 Analog. 2 signal. 3UG48 monitoring relay Introduction Siemens AG 014 System components Overload and s By combining overload/ s with it is now possible to send data that has already been recorded and evaluated in the s directly to the controller.

More information

Innovation on Medium Voltage Switchgear

Innovation on Medium Voltage Switchgear Bruno Rivas, Guarulhos - Brazil, April 2015 Jornadas Técnicas de ABB en Chile Innovation on Medium Voltage Switchgear May 13, 2015 Slide 1 Application 13. Mai 2015 Slide 2 PPMV Brazil Factory Unigear Insourcing

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

Dorman Smith Loadbank 125 MCCB Panel Boards

Dorman Smith Loadbank 125 MCCB Panel Boards Dorman Smith Loadbank 125 MCCB Panel Boards Section 3 MCCB Panel Boards Loadbank 125 Range (250A and 400A Ratings) Overview Key Features ASTA certified busbars with a short circuit rating of 25kA for 1

More information

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection... .3 Product Description Drawout molded case circuit breaker switchboard Front accessible Front connected Through-the-door design drawout mechanism through 600A Insulated case UL 89 breakers up to 200A Visual

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 57 Individual mounting Series inline 35 To accumulator Sealed solenoid enclosure 100 200 Ext. pilot port Pilot valve Function plate From accumulator

More information

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS Overload Relays www.siemens.com/sirius SIRIUS 3RB24

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview Flow Measurement Siemens AG 2012 Overview Design The transmitter is designed as either IP67 NEMA 4X/6 enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack

More information

Safe, seamless, smart

Safe, seamless, smart Series NRX NF and RF Frame low-voltage circuit breakers with Power Xpert Release Technical product guide Safe, seamless, smart Series NRX with Power Xpert Release trip units low-voltage power circuit breakers

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Best practices for making switchgear safer.

Best practices for making switchgear safer. Best practices for making switchgear safer. www.sea.siemens.com www.usa.siemens.com/switchgear Prepared by: Ken Newsome - Consulting Business Developer Kevin Mullins - Consulting Business Developer Joe

More information

What is Zip? Zip Modules... 6 Zip Network... 6 Zip Master Quick Start... 7

What is Zip? Zip Modules... 6 Zip Network... 6 Zip Master Quick Start... 7 Zip Manual Control systems need connections to the real world -- inputs to measure the environment and outputs to control equipment. Zip is North s measurement and control system. This document relates

More information

Low-Voltage Controls and Distribution

Low-Voltage Controls and Distribution SIRIUS SENTRON SIVACON Catalog LV 1 M2D Supplement 21 Low-Voltage Controls and Distribution Answers for industry. Overview For Operation in the Field, High Degree of Protection The intelligent, highly

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

AS-Interface Kompaktstarter Compact Starter

AS-Interface Kompaktstarter Compact Starter AS-Interface Kompaktstarter Compact Starter Handbuch Manual Bestell-Nr./Order No.: 3RK1702-2GB10-2AA0 Important Information, Contents System Description 1 AS-Interface Compact Starter Manual Installation

More information

sentron Technological leader amongst the circuit-breakers: SENTRON Communication

sentron Technological leader amongst the circuit-breakers: SENTRON Communication Seite 2 The information provided in [this brochure/product catalog, etc.] containsmerely general descriptions or characteristics of performance which in case of actual use do not always apply as described

More information

Power-Style QED-2, Series 2 Low Voltage Switchboards

Power-Style QED-2, Series 2 Low Voltage Switchboards Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................

More information

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. www.siemens.com/protection SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities. designed for feeder automation applications This solution allows very fast fault detection

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.4 Contents Description Page Product Description............................. 677 Standards and Certifications...................... 677 Product Selection..............................

More information

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications siemens.com/sirius Answers for industry. SIRIUS 3RB24

More information

SECTION SWITCHGEAR

SECTION SWITCHGEAR SECTION 26 23 13 SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic

More information

BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT

BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/ Giá chưa bao gồm thuế VAT BẢNG GIÁ PLC SIEMENS S7-300 Áp dụng từ 01/01/2011 - Giá chưa bao gồm thuế VAT NO I SIMATIC S7-300 Central Processing Unit 1 6ES7312-1AE13-0AB0 SIMATIC S7-300, CPU 312 CPU WITH MPI INTERFACE, INTEGRATED

More information

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG www.oem.co.uk Contents Shunts Page 3-4 Digital Meters with Bargraph Page 5-6 Large Displays Page 6-7 Power Analyzers, Synchronizing Units Page 8 Recorders Page

More information

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases

Discover TeSys U motor starters open version Starter-controller Non-reversing power bases Discover TeSys U motor starters open version Starter-controller Non-reversing power bases DB0 DB0 LUB, LUB LUB 0, LUB 0 Two types of bases are available, each in two versions: b LUB, LUB Standard power

More information