Relay Panel. B l u e R i d g e T e c h n o l o g i e s

Size: px
Start display at page:

Download "Relay Panel. B l u e R i d g e T e c h n o l o g i e s"

Transcription

1 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Hardware Installation and Setup Instructions Install uide : Page

2 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Install uide : Page Table of Contents Overview Document Component Assembly Dimensions Preparation Door emoval elay Cover emoval Interior emoval Enclosure Mounting Terminations Line Voltage Low Voltage Setup Optional Equipment Visit for Terms and Conditions of Sale Attention This section serves as a notice of the immediate or potential dangers involved when working with the equipment described throughout this manual. Any person involved in installation, maintenance, or service of the equipment should first carefully examine the equipment and read the instructions contained in this manual to ensure that personal and/or equipment injury is avoided. The following safety messages appear throughout this manual to alert of immediate or potential danger to life as well as property. ote : Indicates an important note. Tip : Indicates a helpful tip or trick. Safety eminder : Applicable safety instructions will be included with this symbol. DAE : Indicates an immediately hazardous situation which,if not avoided, will result in serious injury or death. WAI : Indicates a potentially hazardous situation which,if not avoided, may result in serious injury or death. CAUTI : Indicates a potentially hazardous situation which,if not avoided, may result in minor or moderate injury. Disclaimer This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part of the FCC ules. These limits are designated to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Instructions contained in this user s guide should be performed only by qualified persons in accordance with local and national codes. Blue idge Technologies International, LLC and its affiliates assume no responsibility for any consequences related to the improper use of this manual.

3 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Install uide : Page Overview : Document This document provides mounting and connection instructions for the following Blue idge Technologies elay Panel (P) products : P,, 8, with Surface / Flush Mount Doors P enclosures are Type rated and must be mounted in a dry / indoor environment. Sections of this Install uide apply to optional equipment and may not be applicable. Siemens P and Automated Logic Corporation s BACnet ACnet protocols are only available to authorized integrators. For P integration with a Building Automation System (BAS) as well as software configuration refer to the Application uide. Overview : Component The P includes the following items : - P - BT8 BAS etwork Terminator (BT8 Terminator) Overview : Assembly. LEXP Digital Input Expansion Card (LEXP not applicable on P).. Lighting Tough elay (LT). Key Hole Mounting Hole (Top of Panel). Transformer. Earth round Lug. Panel Door 8. elay Covers. Panel Interior 0. Panel Enclosure 0 8 (Figure ) Disconnect line voltage power before performing P installation. All circuits must be tested for wiring errors and shorts prior to P installation. Before handling any P components, the technician should be grounded to prevent circuit board damage.

4 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Overview : Dimensions Install uide : Page P : Enclosure Dimensions Surface Mount Door Dimensions ecessed Mount Door Dimensions 8.00 (mm). (mm) 8.08 (mm).8 (mm).0 (mm). (8mm).0 (0mm) Front Side P : Enclosure Dimensions Surface Mount Door Dimensions ecessed Mount Door Dimensions 8.00 (mm). (mm) 8.08 (mm).8 (mm).00 (mm). (mm).0 (mm) Front Side P8 : Enclosure Dimensions Surface Mount Door Dimensions ecessed Mount Door Dimensions 8.00 (mm). (mm) 8.08 (mm).8 (mm).80 (8mm).0 (8mm).0 (8mm) Front Side (Figure )

5 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Overview : Dimensions Install uide : Page P : Enclosure Dimensions Surface Mount Door Dimensions ecessed Mount Door Dimensions 8.00 (mm). (mm) 8.08 (mm).8 (mm).0 (08mm).8 (088mm).0 (0mm) Front Side (Figure ) Preparation : Door emoval emove the Panel Door from the Panel Enclosure. (Figure ). Open Panel Door. emove fasteners from the door s hinge.. Separate Panel Door from Panel Enclosure. (Figure )

6 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Preparation : elay Cover emoval emove the elay Covers from the Panel Enclosure. (Figure ). Unlock / turn fasteners located near top and bottom of elay Cover.. emove elay Covers by rotating inside edge outward and pulling elay Covers free. Install uide : Page (Figure ) Preparation : Interior emoval emove the Panel Interior from the Panel Enclosure. It is beneficial to mark position of penetrations in the Panel Enclosure prior to removing the Panel Interior. (Figure ). Unfasten the nuts retaining the Panel Interior.. Pull the Panel Interior outward to free it from the Panel Enclosure.. Store the Panel Interior in a secure location free of dust and debris. (Figure ) Voltage Separation 8 Voltage Separation

7 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Install uide : Page Preparation : Enclosure Prior to mounting the Panel Enclosure make penetrations for all applicable bushings and/or conduit. Ensure sufficient clearance for Panel Interior. (Figure ). Ensure the Panel Enclosure is oriented correctly. Key holes should be located at the top of the panel.. Drill or punch the appropriate hole(s) in the Panel Enclosure for the application. Voltage Separation Line Low Front Line (Figure ) Mounting The Panel Enclosure may now be mounted.. Ensure the Panel Enclosure is oriented correctly. Key holes should be located at the top of the panel.. Mark the location of all Panel Enclosure mounting holes to the mounting surface. (Figure 8). Prepare the mounting surface with hardware appropriate to support the panel s weight. See Panel Weight Chart. Hang Panel Enclosure.. emove dust and debris from Panel Enclosure.. einstall Panel Interior. DO OT exceed 0 in-lbs when tightening Panel Interior retention nuts.. Install appropriate bushings, conduit, and wire. Panel Weight Chart elay Panel Capacity P P P8 P Approximate Weight at Full Capacity lbs (. kg). lbs (. kg). lbs (8.8 kg) 8. lbs (. kg)

8 B l u e i d g e Mounting elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Install uide : Page 8 P Mounting Hole Dimensions P Mounting Hole Dimensions.00 (.0mm).00 (.80mm).00 (.0mm).00 (.80mm). (.mm). (.mm).0 (.8mm) Ø 0. (.mm).0 (.0mm) Ø 0. (.mm) P8 Mounting Hole Dimensions P Mounting Hole Dimensions.00 (.0mm).00 (.80mm).00 (.0mm).00 (.80mm). (.mm). (.mm) 0.80 (.mm).0 (.8mm).0 (80.mm) Ø 0. (.mm).0 (0.mm) Ø 0. (.mm) (Figure 8)

9 8 8 8 Signal (+) (reen) (White) CTS-DD Unsheilded VDC (ed) Signal (+) (reen) Digital Input: Two Button Low Voltage Switch (Dry Contact) CTS-DD (White) elay Panel B l u e i d g e round (Black) Switch T e c h ndigital o linput: o g Two i e Button s Low Voltage Switch (Externally Powered) Analog Input: VDC Light Sensor CLP / AW / Conductor CTS Leads : Blue Unsheilded idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Switch Switch V Power Install uide Power : Page Terminations : Line Voltage A Transformer Terminations Signal Signal Switch Complete line voltage terminations. (Figure and 0) Switch. Confirm power is disconnected from the panel. VAC Brown Light Sensor. oute leads as appropriate. Digital Input: -Wire VDC Occupancy Sensor 0VAC (Dry BlackContact). Cut to length and strip as appropriate. V Switch ontact). Complete Transformer Digital Input: and VDC Two LT Button Supply terminations. Low Voltage Switch (Externally Powered) Analog Input: VDC Light Sensor eutral White Earth round. Cap unused primary lead from Transformer. /O (Figure ). Torque each LT screw terminal to in-lbs. itch Switch V Power Power mmon Transformer Specifications Type: 0VA Inherently Limited A Power Signal Signal itch Primary: Dual Tap 0 or VAC +/-0%, 0VA, 0-0 Switch Hz round Secondary: VAC +/-0% Inherently Limited Light Sensor Wire equirement: 8AW Minimum (Solid or Stranded) Switch V Switch V COM /O /C VDC Supply LT Specifications LT Terminations Transformer V Terminations Occupancy Type: VDC Supply Sensor Transformer Terminations UL Listed Phillips / Slot / Square Head Screw Terminals Contact) COM /O /C SPST latching with manual override lever Mounting Hole VAC Brown Electrically operated mechanically held, pulse driven BAS etwork (Input and Output) 0VAC Black BAS etwork (End-of-line VAC Device) Brown Short Circuit Current ating (SCC) VAC eutral White Line In eutral Black atings: Tungsten 0VAC / Ballast VAC / Ballast Signal (+) Earth round A+ Earth round VAC / esistive VAC / esistive VAC elay Output Signal (+ BAS etwork Load (End-of-line Terminal: Device) Universal screw terminal, box type clamp Terminal Capacity (per side): () -0AW or () 8AW (Solid or Signal (- Manual Override LT * Lever Terminations Wire Strip Length S Indicator Stranded copper wire) BT8 (Figure 0) Signal (+) *Do not terminate shield on BAS output. A+ Phillips / Slot / Square Head Screw Terminals D V COM /O /C Mounting Hole Terminations : Low Voltage ccupancy Load S Terminations Sensor All low voltage leads are terminated on the and LEXP. These Line In LEXP Termination screw terminals accept a 0. x.mm slot head screw driver. For reference, Baud ate / Protocol etwork Address otary Switch 0 s BT8 Terminator some terminal blocks may be removed to reveal terminal labels. (Figure ) Dip Switch etwork elay Address Output BAS(+) In. BAS Confirm etwork power (End-of-line is disconnected Device) from the P. otary Switch s BAS(-) In LT. oute leads. Manual Override Lever SW Wire Strip Length Indicator SW SW BT8 BT8 S A+ AUTO OVE A+. Cut to length and strip as appropriate. BT8 Contactor. Insert stripped lead Signal into screw (+) terminal and tighten screw. Terminator Plug A+ (if applicable). epeat for each lead. Contactor Coil Terminations Override Controls S Line In Specifications Load S VDC PW Power LED ntroller Power In: VAC +/-0%, 0VA, 0-0 Hz DD etwork(-) U VDC DD/CA Power Supply Terminations un LED Auxiliary Out: VAC Full Wave ectified BT8 Terminator ork Address otary Switch 0 s etwork Address otary Switch s 0 SW OVE AYS - round (Black) Override Controls Power LED un LED elays - elays -0 LEXP Terminations Port Address Jumper DI DI 0 DI DI DI DI DI DI TO J OF J8 J B D A C ADDESS H L J J DI DI DI 0 DI DI 8 DI DI DI DI DI DI DI DI DI DI DI 8 J J IPUTS - POWE IPUTS - DI 0 DI DI 8 DI DI DI DI DI -8* -* Power LED -* -0* * Position (Dry Contact) / (Externally Powered) DD etwork(+) DD etwork Terminator Jumper VDC AI AI AI AI AI AI -* -8* -* Line J In L(+) + V A A eutral A A A A - -8 DI DI 8 DI DI 0 DI DI DI DI Contactor (-) eutral LEXP VDC Power Supply Line In AI (Analog Input) / DI (Digital Input) / (round) * Position (Dry Contact) / (Externally Powered) J - 0 ELAYS - ELAYS -0 IPUT POWE VAC 0 elays - VDC Out LEXP Port VDC Power Supply Terminations VAC(+) Power In VAC(-) Power In Line In L(+) AUX VAC + VAC(+) Auxiliary Out VAC(-) Auxiliary Out VDC Out eutral (-) - DI DI DI DI DI DI DI DI 8 VDC Power Supply elays -0 DI DI 0 DI DI DI DI DI DI H H LT Port Address Jumper (Figure ) Digital Input: Tw DI DI DI DI DI ADDESS TO J OF B D A C J8 J DI 0 DI DI 8 DI DI DI * Posit YS -0 LEXP Port etwork Address Baud ate / Protocol Dip Switch: BACnet MS/TP T E C VAC(+) Power In VAC(-) Power In etwork Address s etwork Address 0 s Programming 00 Protocol Dip VAC(+) Switch: Auxiliary BACnet Out MS/TP VAC VAC(-) Auxiliary Out g SW SW

10 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Terminations : Low Voltage Digital Input Specifications : two-wire inputs LEXP: two-wire inputs Software Configuration: Maintained, state change, momentary on/off, momentary on, or momentary off Jumper Configuration: 8 input segments, dry contact () or VDC externally powered () Wire equirement / Maximum Length: 8AW (Solid or Stranded) / Dry Contact 00 (m) or externally powered,000 (0m) Install uide : Page 0 Digital Input: Two Button Low Voltage Switch (Dry Contact) Digital Input: Two Button Low Voltage Switch (Externally Powered) Switch Switch Switch Switch Switch V VDC Supply Switch -DD w/vdc External Power Supply VDC Supply V Digital Input: -Wire VDC Occupancy Sensor (Dry Contact) /O VDC (ed) Signal (+) (reen) (White) Power CTS-DD round round (Black) V COM /O /C AW / Conductor Unsheilded CTS Leads V VDC Supply Occupancy Sensor (Figure ) Analog Input Specifications Analog Input: three-wire 0-VDC inputs Wire equirement / Maximum Length: 8AW (Solid or Stranded) / 0 (m) Voltage Switch (Externally Powered) Analog Input: VDC Light Sensor Switch V Power Power A Signal Signal D V DC Supply Switch Switch Light Sensor (Figure )

11 B l u e i d g e elay Panel : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Terminations : Low Voltage BAS etwork Specifications Topology: S-8, conductor (+, -, and shield), daisy chain wiring (no stars or t-taps) Wire equirement / Maximum Length: / 000 (m) BACnet MS/TP Baud ate: DIP switch selectable.k,.k, 8.K, or.8k Device Profile: BACnet Advance Application (AAC) Address ange: selectable with rotary dials Unit Load: Full unit load, devices per MS/TP segment Points: See Application uide and PIC Statement Baud ate: DIP switch selectable.k Address ange: selectable with rotary dials and DIP switch P Baud ate: DIP switch selectable.8k,.k,.k, or 8.K Address ange: selectable with rotary dials See Automated Logic Corporation s AC Wiring Technical Instructions for the latest BACnet ACnet specifications. Install uide : Page Install BT8 Terminator if P is operated as end of line device(first or last device on network). BT8 Terminator requires no specific orientation in relation to the terminal. See Setup for Address and Protocol settings. BAS etwork (Input and Output) BAS etwork (End-of-line Device) Signal (+) A+ Signal (+) A+ BT8 * S *Do not terminate shield on BAS output. S BT8 Terminator (Figure ) DD etwork Specifications Protocol: Digital Device etwork (DD) Address ange: -0, DIP switch selectable Topology: Daisy Chain Wiring (no stars or t-taps) Wire equirement: CLP, AW, conductor, Unsheilded Maximum Stations (w/o external power): 0 CTS-DD Maximum Length (w/o external power): 00 (m) Maximum Stations (w/ external power): 0 one-button, 0 two-button, or a combination for 0 buttons total Maximum Length (w/ external power):,000 (0m) Power / Draw: VDC / ma per CTS-DD DD etwork: CTS-DD DD etwork: CTS-DD w/vdc External Power Supply H L VDC (ed) Signal (+) (reen) (White) CTS-DD VDC Supply V VDC (ed) CLP / AW / Conductor Unsheilded CTS Leads round (Black) H L Signal (+) (reen) (White) round (Black) CTS-DD CLP / AW / Conductor Unsheilded CTS Leads (Figure )

12 0 V VDC Supply 0 0 VDC Supply 0 8 Sensor 8 BAS etwork (Input and Output) BAS etwork (End-of-line Device) B l u e i d g e Signal (+) elay S Panel : Blue idge Technologies 0 Blue idge Technologies *Do not terminate International, shield LLC on BAS All ights output. eserved. P--I-V.00 * A+ Signal (+ Signal (- Install uide : Page Setup configuration and P testing are the final steps of installation. (Figure ) Setup. Confirm power is disconnected from the and the Power / un LED s are not illuminated.. Set the DD etwork Terminator Jumper if utilizing DD etwork. Two devices on the DD etwork should be set for network termination. If the is the end-of-line, terminate the and the device at the opposite end of the network. If the is positioned at a mid-point on the network, terminate devices at the opposite ends of the network either side of the.. Set the Digital Input (DI) Jumpers. ( and LEXP). Set the Baud ate / Protocol Dip Switch for protocol and baud rate.. Set the etwork Address. Testing. Connect power to the. Wait 0 seconds for power up.. Confirm normal LED operation. Power LED: Solid illumination un LED: Continuous blinking. Press and release the Over Button. Confirm the elays turn off.. Press and release the Over Button again. Confirm the elays turn on.. Press and release the Auto Button to exit override mode.. Test procedure complete. Terminations BAS(+) In BAS(-) In BT8 Terminator Plug (if applicable) VDC DD etwork(-) DD etwork(+) DD etwork Terminator Jumper VDC AI AI AI AI AI AI -* -8* -* PW U DD/CA J V A A A A A A - -8 Baud ate / Protocol Dip Switch BT8 S A SW SW AUTO J LEXP IPUT POWE VAC AUX VAC 0 etwork Address otary Switch 0 s etwork Address otary Switch s 0 0 SW OVE ELAYS - ELAYS -0 Override Controls Power LED un LED elays - elays -0 LEXP Port VAC(+) Power In VAC(-) Power In VAC(+) Auxiliary Out VAC(-) Auxiliary Out LEXP Termination Port Address Jumper DI DI DI DI DI TO J OF VDC Po Line In J8 J B D A C ADDESS eutral DI 0 DI DI 8 DI DI DI * Posit DI DI 8 DI DI 0 DI DI DI DI DI DI DI DI DI DI DI DI 8 DI DI 0 DI DI DI DI DI DI AI (Analog Input) / DI (Digital Input) / (round) * Position (Dry Contact) / (Externally Powered) etwork Address etwork Address s etwork Address 0 s 8 SW 8 SW See right for addresses 00- Digital Input (DI) Jumper Dry Contact Externally Powered Baud ate / Protocol Dip Switch: BACnet MS/TP etwork Address s Programming etwork Address 0 s Programming SW SW SW Baud ate / Protocol Dip Switch: etwork Addresses 00- See right for addresses 00- Programming / 00 etwork Address +00 etwork Address +00 Dry Contact 8 Externally Powered SW SW SW etwork Address Baud ate / Protocol Dip Switch: BACnet MS/TP 8 SW Digital Input (DI) Jumper 8 SW SW SW SW 00 SW Baud ate / Protocol Dip Switch: etwork Programming / 00 etwork Ad SW SW Baud ate / Protocol Dip Switch: P Baud ate / Protocol Dip Switch: P Programming 800 Programming DD etwork Terminator Jumper Un-terminated Terminated SW SW DD etwork Terminator Jumper Un-terminated SW Terminated SW SW SW SW J J Baud ate / Protocol Dip Switch: BACnet ACnet ACnet J J Baud ate / Protocol Dip Switch: BACnet ACnet ACnet SW SW (Figure )

13 elay Panel B l u e i d g e Line Low Line : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Front Install uide : Page Optional Equipment P may be equipped with the following optional equipment. (Figure ). Multi-pole Electrically Held Lighting Contactor. Line Voltage Bay. UL Emergency Bypass. Auxiliary Transformer w/earth round Lug. Low Voltage Bay. BACnet IP outer. VDC Power Supply Complete optional equipment termination and configuration.. Confirm power is disconnected from the P.. If applicable remove Dead Front Cover to reveal the Line/Low Voltage Bay a. Unlock / turn fasteners located on inside edge of the cover. b. emove cover by rotating inside edge outward and pulling cover free.. Complete required termination and configuration. See Page for specifications.. If applicable replace Dead Front Cover. a. Align cover tabs with matching slots in Panel Enclosure and rotate the covers inside edge inward. b. Lock / turn fasteners located on inside edge of the cover. (Figure ) WAI : Live Parts Disconnect before servicing. Disconnect provided by installer, located remotely. Panel protected by circuit breaker or equivalent current limiting device. Transformer Input Voltage ating : 0 or VAC +/- 0%, 0 VA, 0 / 0 Hz Transformer Output Voltage ating : VAC +/- 0% elay Short Circuit Current ating (SCC) 0,000 VAC Use only copper conductors rated 0 degree celsius minimum.

14 y COM /O Switch /C elay Panel tact) B l u e i d g e VAC Brown elay Output BAS etwork (End-of-line Device) 0VAC Black : Blue idge Technologies 0 Blue idge Technologies International, LLC All ights eserved. P--I-V.00 Manual Override Lever eutral Wire White Strip Length Indicator BT8 Earth round Install uide : Page Signal (+) A+ Optional Equipment Contactor Coil Terminations Specifications for the optional equipment are listed below. When applicable, LT Terminations Load additional third party documentation is S included for detailed specifications and instructions. Phillips / Slot / Square Head Screw Terminals V BT8 Terminator COM /O /C Low Voltage Bay Mounting Hole ancy Dimensions LT sor Bay Interior:.00 (mm)h x.88 (mm)w x.00 (mm)d Line In P Overall: Add approximately.00 (mm) to overall P height Contactor elay Output Location: Bottom of P eutral BAS etwork (End-of-line Device) Custom Option: Dead Front Cover (reduces bay depth to.0 (0mm)) P equipped with Low Voltage Bay UL Listed, BT8UL08A, US/Canada Line Manual In Override Lever Wire Strip Length Indicator (Figure 8) Line Voltage Bay Signal (+) A+ VDC Power Supply Terminations Dimensions Contactor Coil Terminations Bay Interior:.00 (mm)h x.88 (mm)w x.0 (0mm)D Line In L(+) + P Overall: Add approximately.00 (mm) to overall P height Transformer Load S Terminations ler VDC Out Location: Top of P (maintains left and right wire chases from top of P) eutral (-) - Accessories: Dead Front Cover (separates line and BT8 low Terminator voltage compartments) VDC Power Supply VAC Brown P equipped with Line Voltage Bay UL Listed, UL08A, US/Canada LEXP Terminations LT ress otary Switch 0 s etwork Address otary Switch s Multi-pole Electrically Held Lighting Contactors* (Figure 8) Coil: 0 / VAC Contactors: Pole 0A /O (field convertible to /C) Wire: -0AW or 8-AW with ring terminals (Solid or Stranded) Quantity:,, or Contactors for control of up DI to Jumper circuits VAC Transformer (eplaces Standard Transformer) -* (Figure ) Type: UL Listed Single Tap Power LED Primary: VAC, 0VA, 0 Hz -* Secondary: VAC +/-0% Inherently Limited Wire equirement: 8AW Minimum (Solid or Stranded) Auxiliary Transformer Matched to primary transformer specification 0/ or VAC VDC Power Supply* * (Figure Position (Dry 0) Contact) / (Externally Powered) elays -0 Primary: 00-0VAC (0-0HZ) / Protocol Dip Switch: Secondary: BACnet MS/TP.A VDC +/- % (Adjustable from.-.vdc) LEXP Port Wire: -AW (Solid or Stranded) ing VAC(+) Power In VAC(-) Power BACnet In IP outer* VAC(+) Auxiliary outing Out between BACnet MS/TP and BACnet Ethernet / IP VAC(-) 8Auxiliary Factory Out wired for power 8 and BACnet MS/TP 8 00 (00, 800, 8 and 800 SWavailable at reduced SW network capacity). Ethernet Connection etwork Type: BACnet Ethernet / IP / Protocol Dip Switch: etwork Addresses 00- Data ate: 0/00 Mbps SW SW ramming / 00 Wire equirement etwork Address / Maximum +00 Length: etwork CAT Address / (00m) UL Emergency Bypass UL provides energy management control of emergency lighting ate / Protocol Dip circuits Switch: during BACnet SW MS/TP normal operation while SWmaintaining emergency function during power loss. See the UL Install uide for specific instructions. ramming / Protocol Dip Switch: P ing Override Controls Power LED un LED elays - DI DI DI DI DI WAI SW : Live Parts SW SW Disconnect before servicing. Disconnect provided by installer, located remotely. Panel protected by circuit breaker or equivalent current limiting device. 8 Transformer Input 8Voltage ating : 0 or VAC 8 +/- 0%, 0 VA, 0 / 0 Hz 8 ate / Protocol Dip Switch: Transformer SW Output etwork Voltage Addresses ating : SW 00- VAC +/- 0% elay Short Circuit Current ating (SCC) 0,000 Amps VAC Use only copper conductors rated 0 degree celsius minimum. Programming / 00 etwork Address +00 etwork Address +00 / Protocol Dip Switch: BACnet ACnet * Included third party documentation applies to this equipment. 8 ACnet SW Port Address Jumper DI DI 0 DI DI DI DI DI DI Switch ADDESS TO J OF B D A C J8 J J J DI DI DI 0 DI DI 8 DI DI DI SW DI DI DI DI DI DI DI DI 8 J J IPUTS - POWE IPUTS - DI 0 DI DI 8 DI DI DI DI DI V VDC Supply SW -8* -0* Switch SW SW Phillips / Slot / Square Head Screw Terminals Mounting Hole Transformer Terminations eutral Line In Contactor H H Line In eutral Black Earth round VDC Power Supply Terminations Line In L(+) + eutral (-) VDC Power Supply - Transformer Terminations VDC Out H H Light Sensor VAC Brown eutral Black Earth round (Figure ) (Figure 0)

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration

MAXIOM. Data Sheet. Lighting Relay Panel. Overview Leverage the Power of BAS Integration Data Sheet Lighting Relay Panel Overview Leverage the Power of BAS Integration Exterior with Surface Mount Trim The Series UL Listed, Lighting Control Panel provides the capability to control high voltage

More information

APK INSTALLATION GUIDE

APK INSTALLATION GUIDE Rev 1.3 Dated 9/17/2008 APK INSTALLATION GUIDE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designated

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS LRC0 8X0A Relay Control Panel BACnet MS/TP Enabled INSTALLATI INSTRUCTIS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS!

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions Hardware and Software Instructions Page 1 Attention Page 2 This section serves as a notice of the immediate or potential dangers involved when working with the equipment described throughout this manual.

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN 1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,

More information

Quick Start Guide TS A

Quick Start Guide TS A Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

ACCESS 9340/9360 Meter Input/Output Module

ACCESS 9340/9360 Meter Input/Output Module Installation Manual PMIM-IOMOD-0208 ACCESS 9340/9360 Meter Input/Output Module 9340-60-I/O2222 and 9340-60-I/O26 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

Model# CKM18 Model# CKM36 Model# CKM48 WARNING Installation Instructions Model# CKM18 Model# CKM36 Model# CKM48 WARNING HAZARDOUS VOLTAGES. DISCONNECT FROM SUPPLY BEFORE REMOVING COVERS. NO USER SERVICEABLE PARTS INSIDE. SERVICE BY QUALIFIED PERSONNEL

More information

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION: USE COPPER CONDUCTOR ONLY CAUTION: RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker before installing

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index

More information

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)

More information

Replacing the Power Supply

Replacing the Power Supply APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools

More information

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management

Preparing for a Docking Drawer Slim Installation To prepare for a successful Docking Drawer Slim installation please ensure that the cable management Docking Drawer Install Manual Docking Drawer Slim Series Applicable Models: 0290 00031(W) / 24 0290-00030(W) / 21 0290-00047(W) / 18 0230-00004. r6 1/19/2016 CAUTION READ CAREFULLY Failure to follow these

More information

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel. LX Breaker Control Panels Installation and Setup Procedure Hubbell Building Automation, Inc. 9601 Dessau Road Building One Suite 100 Austin, Texas 78754 512-450-1100 512-450-1215 Fax www.hubbell-automation.com

More information

SEM3 - Embedded Micro Metering Module

SEM3 - Embedded Micro Metering Module SEM - Embedded Micro Metering Module Quick Reference Guide and Installation Instructions Scan QR Code for more information usa.siemens.com/sem Installation! DANGER Hazardous Voltage. Will cause death or

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter Install Guide Revision C (12/18) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Revision C (12/18) Turn off all power supplying equipment

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1

More information

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video

Home Automation, Inc. Model 53A00-1. OmniTouch 5.7 Touchscreen with Video Home Automation, Inc. Model 53A00-1 OmniTouch 5.7 Touchscreen with Video Installation Manual Document Number 53I00-1 Rev A June, 2007 FCC NOTICE This device complies with FCC Rules Part 15. Operation is

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX Instruction Bulletin 63249-500-04A3 07/2010 Fiber Optic Switch Packs SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION SLSPSP101 Single Input Switch Pack SLSPSP102 Dual Input Switch Pack The

More information

Q WIEGAND EXPANSION MODULE

Q WIEGAND EXPANSION MODULE Q WIEGAND EXPANSION MODULE INSTALLATION MANUAL To prevent possible SERIOUS INJURY or DEATH: READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS. The user is strongly recommended to conduct a product

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

Principal LED Qwik Stik Fluorescent Bulb Replacements

Principal LED Qwik Stik Fluorescent Bulb Replacements Principal LED Qwik Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Installing the Tracer MP503 Input/Output Module Ordering number: , Installing the Tracer MP503 Input/Output Module Ordering number: 4950 0490, 4950 0590 Product overview The Tracer MP503 input/output (I/O) module is a field-installed device used to monitor inputs and

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIS! SAVE THESE INSTRUCTIS AND DELIVER TO OWNER AFTER INSTALLATI IMPORTANT SAFETY INSTRUCTIS WARNING To reduce the risk of death, injury or property damage from fire,

More information

rcc.1081 Installation Instructions

rcc.1081 Installation Instructions rcc.1081 Installation Instructions Table of Contents Introduction...1 Specifications...2 Mounting...3 Wiring...5 Wiring Method...7 BACnet Network Wiring...8 Setting BACnet Address...9 Setting the BACnet

More information

CAUTION READ CAREFULLY

CAUTION READ CAREFULLY Docking Drawer Install Manual for DD 21 + 24 Slim Applicable Models: 0290-00030, 0290-00030W, 0290 00031, 0290 00031W 0230-00004. r5 10/21/2015 CAUTION READ CAREFULLY Failure to follow these instructions

More information

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers 2010-12-10 5011699201-PBB1 Eaton Logic Controller ELCB Controllers INSTRUCTION SHEET [Applicable Controllers] ELCB-PB10 ELCB-PB14 ELCB-PB20 ELCB-PB30 ELCB-PB40 IL05001005E 002-1310020-02 Thank you for

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

Square D Clipsal Pascal Automation Controller

Square D Clipsal Pascal Automation Controller Square D Clipsal Pascal Automation Controller SLC5500PACA For Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal Pascal Automation Controller 63249-420-258A2 Instruction

More information

Instruction Bulletin

Instruction Bulletin Instruction Bulletin 63249-401-200/A4 03/2005 POWERLINK TM G3 Controller NF1000G3 for use with POWERLINK G3 Systems Retain for future use. NOTICE Read these instructions carefully and look at the equipment

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

Wa r n i n g-wa r n i n g-wa r n i n g

Wa r n i n g-wa r n i n g-wa r n i n g Installation Instructions of the Power Analyzer Wa r n i n g-wa r n i n g-wa r n i n g Read and understand this manual before connecting device. Death, fire or serious injury can occur from using equipment

More information

Three Phase Residential Solution for Australia, System Design and Installation Guidelines

Three Phase Residential Solution for Australia, System Design and Installation Guidelines Three Phase Residential Solution for Australia, System Design and Installation Guidelines This document describes how to design and install SolarEdge three phase inverters for residential installations.

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation: DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated

More information

Redundant Master Controller Installation Instructions

Redundant Master Controller Installation Instructions Redundant Master Controller Installation Instructions Introduction This publication describes the installation procedure for the 4100-9121, 4100-9122, and 4100-9222 redundant master controller panels.

More information

Power Supply Installation

Power Supply Installation Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Quick Start Guide TS 870 ATS

Quick Start Guide TS 870 ATS Quick Start Guide TS 870 ATS 100A - 800A (with TSC 900 Controller) DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B

INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM. Doc Rev B INSTALLATION INSTRUCTIONS FOR THE MINI-KEY SYSTEM Doc. 6001051 Rev B Page 2 of 7 Doc 6001051 Rev B IMPORTANT NOTICES The Mini-Key system is a very reliable and easy to use system. However, damage could

More information

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME Reclosers Form 4C Microprocessor-Based Recloser Control Analog Current Metering Accessory KME4-82-1, KME4-82-2 Installation and Operation Instructions Service Information S280-77-8 Figure 1. Kyle Form

More information

Series Amp Quick Connect Input and Output Power Panels

Series Amp Quick Connect Input and Output Power Panels Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is

More information

THE CTB08D LIGHT CONTOLLER

THE CTB08D LIGHT CONTOLLER THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

RMB Peripheral Units Installation Guide

RMB Peripheral Units Installation Guide RMB Peripheral Units Installation Guide Part Number 65-000101 2011 by Kentrox, Inc. All rights reserved. Copyright 2011 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication

More information

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions

S Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Reclosers Kyle Type VXE Electronic Control SCADA Input/Output Board Installation and Operation Instructions Cooper Power Systems Service Information S0-6- Applicable to VXE5 reclosers serial number 006

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216

More information

Wireless Adapter (WA100-PM) i. Installation Instructions

Wireless Adapter (WA100-PM) i. Installation Instructions i. Installation Instructions The Daintree WA100-PM Wireless Adapter forms part of the Daintree ControlScope wireless controls solution for smart commercial and industrial buildings. It transmits and receives

More information

Temperature. Power requirements. Weight. Dimensions

Temperature. Power requirements. Weight. Dimensions Installing the Tracer Summit BMTX Building Control Unit Ordering numbers: BMTX001AAB000, BMTX001AAB010, BMTX001AAB001, BMTX001AAB011, BMTX001BAB000, BMTX001BAB010, BMTX001BAB001, BMTX001BAB011, BMTX001DAB000

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Home Automation, Inc. Model 32A00-1. OmniTouch Touchscreen

Home Automation, Inc. Model 32A00-1. OmniTouch Touchscreen Home Automation, Inc. Model 32A00-1 OmniTouch Touchscreen Installation Manual Document Number 32I00-1 Rev A July, 2003 FCC NOTICE This device complies with FCC Rules Part 15. Operation is subject to the

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

Principal LED Street Stik Fluorescent Bulb Replacements

Principal LED Street Stik Fluorescent Bulb Replacements Principal LED Street Stik Fluorescent Bulb Replacements LED Retrofit Guide (PL-RT1-001) WARNING Installation must only be performed by a licensed electrician. To prevent death, injury or damage to property

More information

Infosystem Remote Touchscreen Installation Instructions

Infosystem Remote Touchscreen Installation Instructions Infosystem Remote Touchscreen Installation Instructions DOC. #569102100 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements

More information

Installing Your 1394 Drive Interface Module

Installing Your 1394 Drive Interface Module Installation Instructions Installing Your Drive Interface Module (Catalog Number -DIM) Introduction This publication provides installation instructions for adding the Drive Interface Module to your system.

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

LiteKeeper-8. General Information. Getting Started. Wiring the Transformer. Mounting the Enclosure

LiteKeeper-8. General Information. Getting Started. Wiring the Transformer. Mounting the Enclosure +24 8 +24 VD D GND 3 5 7 RELAY OUTPUTS 2 4 6 8 Installation Sheet General Information LiteKeeper-8 Model# Model# Model# Model# LK8-NO LK8-LR LK8-MR LK8-TPR The LiteKeeper-8 is shipped in one package. The

More information

NSD/M1 Installation Instructions

NSD/M1 Installation Instructions NSD/M1 Installation Instructions DOC. #560502200 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance with the requirements set forth in UL

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24

Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document

More information

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Sidewinder Pumps Inc. AC C1D2 Timer/Controller Sidewinder Pumps Inc. AC C1D2 Timer/Controller Page 1 of 14 Rev 4/26/17 Table of Contents 1. Warnings --------------------------------------------------------------------------------------------------

More information

PLC Racks IC697CHS782/783

PLC Racks IC697CHS782/783 5 1 PLC Racks IC697CHS782/783 (IC697CHS782/783) datasheet Features Accepts 3rd Party VME modules which require 0.8 spacing. Accepts all IC697 PLC module types. Rear mount rack mounts in a 10 (254 mm) deep

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

TT-NRM. Network Relay Module Installation Instructions WARNING:

TT-NRM. Network Relay Module Installation Instructions WARNING: TT-RM etwork Relay Module Installation Instructions TT-RM-BASE unit with four TT-RM-2RO modules removed Description The TraceTek etwork Relay Module provides multiple relay outputs for switching alarm

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

SuperBus 2000 Phone Interface/Voice Module Installation Instructions SuperBus 2000 Module Installation Instructions Product summary The SuperBus 2000 (PIV) Module provides phone and voice functions for the Concord, Concord 4, and Concord Express (v4) panels. The PIV module

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Adaptor Model No. CZ-CFUNC1U For your safety Read the following instructions carefully, and carry out secure installation and electrical work. The precautions given in this manual

More information

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II Reclosers Form 4C Microprocessor-Based Recloser Control KME4-88-1 (120V) and KME4-88-2 (240V) Analog Current Metering Accessory Design II Service Information S280-77-6 961015, 961016 Figure 1. Kyle KME4-88

More information

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

Wireless Fixture Adapter (WFA100-SN) Installation Instructions Installation Instructions The Daintree Wireless Fiture Adapter () forms part of Daintree s Controlscope Manager (CSM) in commercial and industrial buildings. It transmits and receives messages over the

More information

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1.

Installation Instructions Installation Guidelines. Product Summary. For the maximum number of bus devices and touchpads per panel see Table 1. Document Number: 466-1632 Rev. B September 2000 Product Summary The ITI SuperBus 2000 2 x 20 LCD (liquid crystal display) Alphanumeric Touchpad gives you complete on-site system programming and operation

More information

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09.

Encoder Firmware V User s Manual. Outdoor PTZ Camera Hardware Manual KCM /05/09. Encoder Firmware V4.06.09 User s Manual Outdoor PTZ Camera Hardware Manual KCM-8211 2013/05/09 1 Table of Contents Precautions... 3 Introduction... 4 List of Models... 4 Package Contents... 5 Safety Instructions...

More information

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE 3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE -ST-01 Page 1 of 10 November 2016 2016 Copyright Lite-On Technology Corporation ALL RIGHTS RESERVED. Lite-On is a trademark of Lite-On Technology

More information

Installing Powerlink NF3500G4 Controllers

Installing Powerlink NF3500G4 Controllers Installing Powerlink NF3500G4 Controllers for Use with Powerlink Systems RETAIN FOR FUTURE USE Installing Powerlink NF3500G4 Controllers 63249-420-374A3 Instruction Bulletin 09/2015 2 2015 Schneider Electric.

More information

LITETOUCH HYBRID WALL BOX DIMMER INSTALLATION INSTRUCTIONS

LITETOUCH HYBRID WALL BOX DIMMER INSTALLATION INSTRUCTIONS READ INSTRUCTIONS PRIOR TO INSTALLATION OF EQUIPMENT OR YOU MAY VOID THE WARRANTY! LITETOUCH INSTALLATION INSTRUCTIONS The LiteTouch Hybrid Wall Box Dimmer is a configurable lighting control device, that

More information

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri Figure 3.14 Main speed frequency reference. Multi-function programmable Safety input Forward run/stop Reverse run/stop External fault Fault reset Multi-step speed 1 main/aux switch Multi-step speed 2 Jog

More information

D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL

D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL TM D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL General Cautions & Warnings! To prevent electrical shock or potential fire hazards, do not expose these products to

More information

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE WARNINGS 1. All servicing should be performed by qualified service personnel. 2. WARNING, Battery may explode if mistreated. Do not recharge, disassemble

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A RMB-3 Peripheral Unit Installation Guide INSTALLATION GUIDE Westell Technologies Part # 030-300812 Rev. A Copyright 2017 by Westell Technologies. All Rights Reserved. The material discussed in this publication

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Product 7160-0318-00 THROUGH 7160-0318-12 PANASONIC TOUGHBOOK CF-31 DOCKING STATION This instruction sheet is for the following products: Panasonic Toughbook CF-31 docking station

More information

Installation Instructions for the AUTOcard-SA System

Installation Instructions for the AUTOcard-SA System Installation Instructions for the AUTOcard-SA System IMPORTANT NOTICE The AUTOcard-SA system is a very reliable and easy to use system. However, damage could occur if it is installed incorrectly. In particular,

More information

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc. X-12s User Manual Revisions Revision Description 1.0 Page 2 Initial release Introduction Section 1: Introduction The X-12s 8-Relay expansion module is used with the X-600M controller. The X-12s has eight

More information