Welcome to VPLEX VS6 FRU Replacements.

Size: px
Start display at page:

Download "Welcome to VPLEX VS6 FRU Replacements."

Transcription

1 Welcome to VPLEX VS6 FRU Replacements. Copyright 2016 EMC Corporation. All Rights Reserved. Published in the USA. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED AS IS. EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. The trademarks, logos, and service marks (collectively "Trademarks") appearing in this publication are the property of EMC Corporation and other parties. Nothing contained in this publication should be construed as granting any license or right to use any Trademark without the prior written permission of the party that owns the Trademark. EMC, EMC², the EMC logo, AccessAnywhere Access Logix, AdvantEdge, AlphaStor, AppSync ApplicationXtender, ArchiveXtender, Atmos, Authentica, Authentic Problems, Automated Resource Manager, AutoStart, AutoSwap, AVALONidm, Avamar, Aveksa, Bus-Tech, Captiva, Catalog Solution, C-Clip, Celerra, Celerra Replicator, Centera, CenterStage, CentraStar, EMC CertTracker. CIO Connect, ClaimPack, ClaimsEditor, Claralert,cLARiiON, ClientPak, CloudArray, Codebook Correlation Technology, Common Information Model, Compuset, Compute Anywhere, Configuration Intelligence, Configuresoft, Connectrix, Constellation Computing, CoprHD, EMC ControlCenter, CopyCross, CopyPoint, CX, DataBridge, Data Protection Suite. Data Protection Advisor, DBClassify, DD Boost, Dantz, DatabaseXtender, Data Domain, Direct Matrix Architecture, DiskXtender, DiskXtender 2000, DLS ECO, Document Sciences, Documentum, DR Anywhere, DSSD, ECS, elnput, E-Lab, Elastic Cloud Storage, Xaminer, Xtender, EMC Centera, EMC ControlCenter, EMC LifeLine, EMCTV, Enginuity, EPFM. eroom, Event Explorer, FAST, FarPoint, FirstPass, FLARE, FormWare, Geosynchrony, Global File Virtualization, Graphic Visualization, Greenplum, HighRoad, HomeBase, Illuminator, InfoArchive, InfoMover, Infoscape, Infra, InputAccel, InputAccel Express, Invista, Ionix, Isilon, ISIS,Kazeon, EMC LifeLine, Mainframe Appliance for Storage, Mainframe Data Library, Max Retriever, MCx, MediaStor, Metro, MetroPoint, MirrorView, Mozy, Multi-Band Deduplication,Navisphere, Netstorage, NetWitness, NetWorker, EMC OnCourse, OnRack, OpenScale, Petrocloud, PixTools, Powerlink, PowerPath, PowerSnap, ProSphere, ProtectEverywhere, ProtectPoint, EMC Proven, EMC Proven Professional, QuickScan, RAPIDPath, EMC RecoverPoint, Rainfinity, RepliCare, RepliStor, ResourcePak, Retrospect, RSA, the RSA logo, SafeLine, SAN Advisor, SAN Copy, SAN Manager, ScaleIO Smarts, Silver Trail, EMC Snap, SnapImage, SnapSure, SnapView, SourceOne, SRDF, EMC Storage Administrator, StorageScope, SupportMate, SymmAPI, SymmEnabler, Symmetrix, Symmetrix DMX, Symmetrix VMAX, TimeFinder, TwinStrata, UltraFlex, UltraPoint, UltraScale, Unisphere, Universal Data Consistency, Vblock, VCE. Velocity, Viewlets, ViPR, Virtual Matrix, Virtual Matrix Architecture, Virtual Provisioning, Virtualize Everything, Compromise Nothing, Virtuent, VMAX, VMAXe, VNX, VNXe, Voyence, VPLEX, VSAM-Assist, VSAM I/O PLUS, VSET, VSPEX, Watch4net, WebXtender, xpression, xpresso, Xtrem, XtremCache, XtremSF, XtremSW, XtremIO, YottaYotta, Zero-Friction Enterprise Storage. 1

2 This course covers how to replace. Procedures are used to guide you through the steps along with videos showing the actual replacement of the units. 2

3 This module focuses on covering the preliminary FRU replacement information such as needed service software tools, the use of SSH and web server information. It will list the scripted and manual FRU procedures. 3

4 The latest VPLEX VS6 FRU procedures are always available in SolVe Desktop. There are CLI-guided and scripted procedures that guide you through replacements step by step including gathering health check and diagnostics information. The FRU replacements are typically started with the command VPlexadmin replace-fru and then select the faulted FRU from the replacement menu. On the other hand, there are some manual replacement procedures. No script guides you through the needed steps. The FRU manual lists all the steps which need to be executed manually. This manual process starts with disabling the call-home, gathering health information, and verifying the faulted unit for replacement. Another important area for FRU replacements is to know if the procedure is performed on an un-configured VPLEX VS6 Cluster, which means the configuration commands for EZ- Setup have not been run. An example could be that a faulted Management Module Control Station (MMCS) failed the EZ-Setup and it was determined to replace this MMCS. In this case the replacement procedure for an un-configured MMCS should be used. However, if an MMCS fails in a successfully configured VPLEX VS6 Cluster then the replacement procedure for a configured MMCS needs to be used. 4

5 The EMC VPLEX VS6 cabinet has a laptop tray in the front at the U20 location. The red Ethernet service cable connected to MMCS-A should be available to connect to the service laptop. The service laptop needs PuTTY version 0.60 or later for SSH connections, WinSCP or a similar tool for copying files to the VPLEX management module control stations, and a web browser and Flash Player version or higher for the VPLEX GUI. 5

6 When connected to the red Ethernet service cable, the laptop should automatically get an IP address from the DHCP server running on the MMCS. Use an SSH tool like PuTTY and configure it to the service IP address with the default port 22 for the connection type SSH. You can then save the session and open the session to the MMCS-A. 6

7 You can also connect to the same service port IP address with a browser using HTTP. In the FRU replacement screen, the commands are listed to start the scripted FRU replacement procedure. After you have logged into the MMCS-A and connected to the VPlexcli using SSH, you execute these commands. While going through the FRU Replacement script, there are entries for illustrations in the GUI. They can help with an easier selection and show how to remove and replace a FRU through illustrations. 7

8 With the VS6 the call-home feature should be used. A warning message is generated if a FRU is degraded. If a FRU is faulted, an error message is sent. The information in the call-home messages and the information gathered through troubleshooting come from the EMC support center and generate service calls. VPlexcli context information and health check commands can also be used to detect and verify faulted FRUs. In Unisphere for VPLEX, certain failures are displayed under the Monitoring tab in System Health. Service tasks can also be generated out of troubleshooting an issue. Some FRUs might not generate call homes or unique warning or error messaging. Performance issues can be one of the symptoms. Replacing an SFP or I/O Module might be a direct result from troubleshooting a customer SR. 8

9 When the faulted unit is selected in the replacement menu, a summary is displayed and should be checked against the FRU replacement call-home or service center information. Serial and part numbers can easily be found on the faulted unit. First we see pull-out tags for the engine chassis and the BBUs. Each fan module has its serial number and part number in the front. The management as well as the I/O modules have their serial and part number on the handle. The pull-out tag with serial and part number is from an InfiniBand switch. Other FRU components also have the S/N and part number easily available. 9

10 In the scripted procedures, VPLEX VS6 uses amber marker LEDs for engine, director, and unit to physically identifying the selected or faulted FRU to avoid errors. Here the engine marker and director marker can be seen. During a FRU replacement for a PSU, for example, the script also marks the PSU that was chosen in the menu and needs replacement. Another example for the use of amber marker LEDs is with a director fan. Fan replacements are a manual procedure, not script driven. The amber LED used for a faulted fan is enabled when the fault occurs and not activated with a replacement script. 10

11 This table of VPLEX VS6 FRUs shows which FRU is covered by a scripted, CLI-guided procedure, as well as which FRU has a procedure when the cluster has not yet been configured with EZ-Setup. Most of the FRUs are monitored and trigger a call-home. Some might not directly call home but can be identified through performance issues. 11

12 All FRU replacements in this table follow manual steps. As an example, IB switches are not directly monitored, but in case of a failure, this will show up in the internal communication statistic and IB-group presence. VPLEX monitors which constantly monitor software status, IO status, and hardware status, should detect the faulted IB connectivity. 12

13 This module focuses on the replacement of FRUs in the VPLEX VS6. Upon completion of this module you should be able to list all the VPLEX VS6 FRUs and perform their replacements. 13

14 This is a list of all the FRUs in the VPLEX VS6. All these FRUs have replacement procedures that must be followed when a replacement is needed. Perform this procedure only after a VPLEX cluster has been configured for operation by running the EZ-Setup utility. Do not run the procedure on a new cluster that has not yet been configured. FRUs listed here with an asterisk also have a procedure when the VPLEX cluster has not been configured. Make sure you use the correct replacement procedure. 14

15 Replacing a DIMM or memory module is completed from the front. You need to identify the engine, director, and the location of the faulted DIMM. The top view of the director shows four banks of DIMMs. Each bank has a total of 2 DIMMs, eight DIMMs per director in specific locations. Click the Launch button to view the DIMM replacement demonstration. 15

16 Two commands in the CLI context for DIMMs are shown here. The output of the first command displays the names of the DIMMs which also represent their location in the DIMM banks. The output of the second command shows the details per DIMM, its operational status, part and serial number. 16

17 Replacing the director Solid State Drive (SSD) is completed from the front. You need to identify the engine and director. The top view of the director shows the location of the SSD. The director supports the M.2 SSD - SMART Modular Technologies - with 60 mm in length. The thumb screw assembly holds the SSD in place. Click the Launch button to view the SSD replacement demonstration. 17

18 The command for the SSD in the VPlexcli context is shown here. The output lists the Solid State Drive (SSD) status, part number, and serial number. 18

19 The director chassis itself is a FRU. The director replacement chassis needs to be populated with the SSD, DIMM, BBUs, and Fans of the faulted director. The director FRU has two replacement procedures for the configured and un-configured state of the VPLEX cluster (after and before EZ-Setup). The difference between these procedures might only be very small but it is extremely important to use the correct procedure. In this demonstration the procedure for the configured director replacement is followed. Click the Launch button to view the director replacement demonstration. 19

20 A command for a director in the VPlexcli context is shown here. The output shows director attributes and director contexts dimms, fan-modules, internal-disks, io-modules, ports, and sfps. 20

21 Also serviced from the front of the VPLEX are the Battery Backup Units (BBU). Each engine has four: A0, A1, B0, and B1. The replacement script will mark the engine. The faulted BBU needs to be identified. Make sure you use the labeling on the engine chassis for selecting the right one. Click the Launch button to view the BBU replacement demonstration. 21

22 Two commands for the BBUs in the VPlexcli context are shown here. BBUs are in the engine context. The second command displays details of all the BBUs in one engine including battery charge and test, operational status, part and serial numbers. 22

23 Fan modules are serviced from the front. Each director has six fans named A0 to A5 respectively and B0 to B5. Labels on the engine chassis show the locations. If one fan needs to be replaced the director is still up and running. If a second fan on the same director fails or is pulled out, the director shuts down. The fan replacement is a manual procedure. Click the Launch button to view the director fan replacement demonstration. 23

24 Two commands for the Fan modules in the VPlexcli context are shown here. Fans are in the director/hardware context. The details for each fan include Fan status, marker LED, and operational status. 24

25 Power Supply Units (PSU) are serviced from the rear. Each engine has four PSUs named A0, A1 and respectively B0, B1. Labels on the engine chassis show the locations. If one PSU needs to be replaced the director is still up and running. Click the Launch button to view the PSU replacement demonstration. 25

26 Two commands for the PSUs in the VPlexcli context are shown here. PSUs are listed in the engine context. The details for each PSU include marker LED status, operational status, part and serial numbers. 26

27 The Base Modules (BM) are serviced from the rear. There are two de-populated BMs in an engine. The Base Module replacement is a manual procedure. Click the Launch button to view the base module replacement demonstration. 27

28 There are three Fibre Channel I/O Modules in each director for Front End, Back End, and WAN connectivity named A0, A1, A2 and respectively B0, B1, and B2. Replacement FC I/O modules come without the SFPs. SFPs are swapped from the faulted FC I/O module to the replacement module. Click the Launch button to view an FC I/O module replacement demonstration. 28

29 Two commands for displaying I/O modules in the VPlexcli context are shown here. I/O modules are listed in the director/hardware context. A director has three FC I/O modules and one InfiniBand I/O module (A3 or respectively B3). The details for the FC I/O modules include marker LED, operational status, part and serial numbers, and type. 29

30 There is one two-port InfiniBand I/O Module in each director for intra-cluster communication, named A3 and respectively B3. In a single-engine VPLEX cluster the two ports of one director are connected directly to the other director. In a dual- or quad-engine VPLEX cluster, all InfiniBand ports are connected to the InfiniBand switches. Click the Launch button to view the InfiniBand I/O module replacement demonstration. 30

31 Two commands for displaying I/O modules in the VPlexcli context are shown here. I/O modules are listed in the director/hardware context. A director has one InfiniBand I/O module, A3 or respectively B3. The details for the InfiniBand I/O modules include marker LED, operational status, part and serial numbers, slot number and type. 31

32 The FC I/O modules have SFPs in each port for the 16 Gb connectivity. The SFP replacement is a manual procedure. Click the Launch button to view an SFP replacement demonstration. 32

33 A command for the SFP information in the VPlexcli context is shown here. SFPs are in the director/hardware context. The details for each SFP include part number, serial number, rxpower, tx-power, and temperature. Values for current-rx-power and current-tx-power should not be less than 100. Power values lower than 100 generate a call home event. 33

34 InfiniBand switches are serviced from the rear. They are part of the configuration in dualand quad-engine VPLEX clusters and connect the intra-cluster communication redundantly. Each switch and one InfiniBand port of each director is part of an IB group. With one InfiniBand switch failure, the intra-cluster communication between the directors is still possible and VPLEX operations are still online. The InfiniBand switch replacement is a manual procedure. Click the Launch button to view the IB switch replacement demonstration. 34

35 In multi-engine VPLEX clusters engine 2, 3, and 4 have two Management Modules (MM), one per director. They are referenced to as mgmt-module-a and mgmt-module-b. The management module provides Ethernet management network connectivity for the cluster as well as serial and USB connection to each of the directors. Click the Launch button to view the management module replacement demonstration. 35

36 Two commands for the mgmt-modules in the VPlexcli context are shown here. The Management Modules (MM) as well as the Management Module Control Stations (MMCS) are in the same engine context. They are both referenced to as mgmt-modules, here mgmt-module-a and mgmtmodule-b. The details for the management module A in engine 2 include the module type, here management-module, the operational status, the part number (different from the MMCS), and serial number. 36

37 Two Management Module Control Stations (MMCSs) are in the base engine 1 of the VPLEX cluster. There is an MMCS-A and an MMCS-B. A service person typically connects to MMCS- A for any replacement procedures. However, if the MMCS-A needs to be serviced and no service port connection to MMCS-A is possible, MMCS-B is partially used for the replacement. The MMCS modules also provide Ethernet management network connectivity for the cluster. In the replacement video we will follow the VPLEX MMCS configured procedure, but remember there is also an MMCS replacement procedure for an un-configured VPLEX cluster. Click the Launch button to view the MMCS-A replacement demonstration. 37

38 Two commands for the MMCS in the VPlexcli context are shown here. MMCS and MM (Management Module) are in the same engine context. They are both referenced to as mgmt-modules, here mgmt-module-a and mgmtmodule-b. The details for the MMCS include the module type, here mmcs, the operational status, the part number (different from the MM), and serial number. 38

39 In this FRU replacement scenario both management module control stations need to be replaced. A possible scenario could be that it was determined that internal network issues resulted from two faulty MMCSs. The MMCS modules provide Ethernet management network connectivity for the cluster. The Dual MMCS replacement sequence will first replace MMCS-B, then replace, re-image and restore MMCS-A. The factory image on MMCS-B is used to re-image MMCS-A to the cluster version. After a successfully completed replacement of MMCS-A, MMCS-B is reimage and restored. Click the Launch button to view the dual MMCS replacement demonstration. 39

40 One MRJ21 cable assembly is connected with its keyed connector to the MMCS-A, another one to the MMCS-B. It provides connectivity to the customer management network (black cable), as well as the redundant internal management networks in dual and quad engine configurations. The lime-colored (A-side) cable is the.252 subnet within the VPLEX cluster. The purplecolored (B-side) cable is the.253 subnet. The MRJ21 cable assembly replacement follows a manual procedure. For further Ethernet cabling in dual and quad engine VPLEX VS6 clusters view the provided cabling animation. Click the Launch button to view the MRJ21 cable assembly replacement demonstration. 40

41 If an engine chassis replacement needs to be performed, the single engine VPLEX cluster would have a considerable data unavailability downtime. With dual and quad engine clusters, the replacement can be performed with continued production. There might be a reduction in performance. Shown is the engine chassis of the VPLEX VS6 the replacement chassis would come without the disk fillers which also have to be moved from the faulted engine chassis to the replacement chassis, just like both directors with BBUs and director fans, and all the I/O modules and MMs or MMCSs. The engine chassis has a configured and un-configured procedure. A transport lift is needed because of the weight of the 4-U VS6 engine. 41

42 The command for displaying an engine in the VPlexcli context shows engine attributes and contexts. Listed are among others the attributes for ip-seed, enclosure-id, the engine family, part number and serial number. The VPlexcli context for the engine lists battery-backup-units, directors, fans, mgmt-modules, and power-supplies. 42

43 The uninterruptible power supplies back up the InfiniBand switches. UPS-A backs up IB switch A while UPS-B backs up IB switch B. Just like the InfiniBand switches, UPS are only part of the VPLEX VS6 configurations in dual and quad engine clusters. The procedure follows manual steps. When replacing a faulty UPS, the other UPS and InfiniBand connections need to be functional. Commands that check these conditions are run during the procedure. After the replacement, the UPS status should be back to normal and the InfiniBand connections fully functional. 43

44 The commands for the UPS display the names, battery status, operational status, part and serial numbers. 44

45 In VPLEX Metro configuration the FC Com cable is used for the WAN connectivity. The connectivity is setup in redundant FC port groups. The command connectivity validate-wan-com checks for WAN COM connectivity. If there are any connections missing, it will list the faulty connections. The FC port groups will only show PARTIAL connectivity. When the faulty FC WAN cable(s) is replaced, the two FC port groups should show their expected connectivity as FULL. Be aware that the output may not show missing connectivity if the failure is intermittent. For further cabling details use the provided cabling demonstration. 45

46 The UPS serial cables connect the UPS with the MM of the second engine. They are used to monitor the UPS. If a cable has faulted or is not connected, the command shown here will display the operational status of the UPS as being removed. No other information on the UPS is available. For this process it is important to locate the right UPS - the peer needs to be operational. Both UPSs and IB switches should be online again after the UPS replacement. For the cabling in dual and quad engine VPLEX VS6 clusters, view the provided cabling demonstration. 46

47 AC power cables use the colors grey and black in the VPLEX VS6 cluster. Grey cables are used for the A-side connections, black cables for the B-side connections. There are three scenarios of possible AC power cable failures: first - the connection between the Power Distribution Unit (PDU) and the VPLEX PSUs; second - AC cables between the PDUs and UPSs; third - AC power cables between UPSs and InfiniBand switches. All cables should always be checked if they are seated completely and the bail is in place. If a cable needs to be replaced, follow the AC power cable manual replacement procedure. For the AC power cabling view the provided cabling demonstration. 47

48 Use the shell command VPlexPlatformHealthCheck. It pings all IP addresses in the cluster and identifies unreachable components as shown in this output example. The replacement manual has IP address tables for the dual and quad engine VPLEX cluster configurations to determine which internal cluster management cable needs to be replaced. Purple and lime cables are used in dual- and quad-engine VPLEX VS6 clusters. Use the provided cabling demonstration for more details. 48

49 InfiniBand cables are used in single engine VPLEX VS6 cluster to connect the two directors in the base engine. The InfiniBand backbone handle the intra-cluster communication. With dual- and quad-engine VPLEX VS6 cluster, the InfniBand port are connected to the InfiniBand switches. The output confirms that the cluster has full connectivity in respect to intra-cluster communication using InfiniBand. If a cable is faulty then the command output would show which cable is faulty. The faulty cable on a specific engine and director reports that it is Missing all expected connectivity. 49

50 This course covered the FRU procedures, access tools, and physical identification methods. The videos for each FRU showed in detail the software and physical replacement steps for the faulted units. The new VPLEX CLI context commands helped to identify and get the status of FRUs This concludes the training. Proceed to the course assessment on the next slide. 50

51 Do not record. Feedback Link will be inserted by Production Team. 51

52 52

Welcome to the VxRail Appliance Version 4.0 Technical Differences Course.

Welcome to the VxRail Appliance Version 4.0 Technical Differences Course. Welcome to the VxRail Appliance Version 4.0 Technical Differences Course. Copyright 2016 EMC Corporation. All Rights Reserved. Published in the USA. EMC believes the information in this publication is

More information

TECHNICAL NOTES. Technical Notes P/N REV 01

TECHNICAL NOTES. Technical Notes P/N REV 01 TECHNICAL NOTES EMC NetWorker Module for Microsoft: Performing Exchange Server Granular Recovery by using EMC NetWorker Module for Microsoft with Ontrack PowerControls Release 3.0 Technical Notes P/N 302-000-404

More information

Welcome to Avamar 7.4 Technical Differences: Virtualization Enhancements.

Welcome to Avamar 7.4 Technical Differences: Virtualization Enhancements. Welcome to. Copyright 2016 EMC Corporation. All Rights Reserved. Published in the USA. EMC believes the information in this publication is accurate as of its publication date. The information is subject

More information

Introduction to ScaleIO. Welcome to Introduction to ScaleIO

Introduction to ScaleIO. Welcome to Introduction to ScaleIO Welcome to Copyright 2016 EMC Corporation. All Rights Reserved. Published in the USA. EMC believes the information in this publication is accurate as of its publication date. The information is subject

More information

EMC VNX VNXe3150. Installation Guide P/N REV 01

EMC VNX VNXe3150. Installation Guide P/N REV 01 MC VNX VNXe35 Installation Guide P/N 3-3-924 RV Copyright 22 MC Corporation. All rights reserved. Published in the USA. Published June, 22 MC believes the information in this publication is accurate as

More information

EMC Atmos Capacity Reporting Tool

EMC Atmos Capacity Reporting Tool EMC Atmos Capacity Reporting Tool Version 1.1 User Guide P/N 300-013-322 REV A01 Copyright 2010-2011 EMC Corporation. All rights reserved. Published in the USA. Published November, 2011 EMC believes the

More information

EMC VFCache. Troubleshooting Guide. v1.0 FOR WINDOWS AND LINUX P/N

EMC VFCache. Troubleshooting Guide. v1.0 FOR WINDOWS AND LINUX P/N EMC VFCache v1.0 Troubleshooting Guide FOR WINDOWS AND LINUX P/N 300-013-647 Copyright 2012 EMC Corporation. All rights reserved. Published in the USA. Published January, 2012 EMC believes the information

More information

EMC VNX VNX-VSS100. Installation Guide REV 01 P/N

EMC VNX VNX-VSS100. Installation Guide REV 01 P/N EMC VNX VNX-VSS100 Installation Guide P/N 300-015-424 REV 01 Copyright 2014 EMC Corporation. All rights reserved. Published in the USA. Published September, 2014 EMC believes the information in this publication

More information

EMC VNX VNX7500 Block

EMC VNX VNX7500 Block EMC VNX VNX7500 Block Installation Guide P/N 300-012-933 REV 04 Copyright 2012 EMC Corporation. All rights reserved. Published in the USA. Published June, 2012 EMC believes the information in this publication

More information

Microsoft Exchange 2010 or Exchange 2007 on EMC VNXe Series

Microsoft Exchange 2010 or Exchange 2007 on EMC VNXe Series Contents Microsoft Exchange 2010 or Exchange 2007 on EMC VNXe Series h8168.4 2 Contents Copyright 2011, 2013 EMC Corporation. All rights reserved. Last published February 2013 EMC believes the information

More information

ApplicationXtender Image Capture Quick Reference. EMC Corporation Corporate Headquarters: Hopkinton, MA

ApplicationXtender Image Capture Quick Reference. EMC Corporation Corporate Headquarters: Hopkinton, MA ApplicationXtender Image Capture 5.30 Quick Reference EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994-2005 EMC Corporation. All rights reserved.

More information

EMC VNX VNXe3300. Installation Guide P/N REV 05

EMC VNX VNXe3300. Installation Guide P/N REV 05 EMC VNX VNXe3300 Installation Guide P/N 300-011-182 REV 05 Copyright 2012 EMC Corporation. ll rights reserved. Published in the US. Published June, 2012 EMC believes the information in this publication

More information

Microsoft SharePoint Server 2010 on EMC VNXe Series

Microsoft SharePoint Server 2010 on EMC VNXe Series Microsoft SharePoint Server 2010 on EMC VNXe Series h8287.1 h8287 Copyright, 2012 EMC Corporation. All rights reserved. Published February, 2012 EMC believes the information in this publication is accurate

More information

User s Quick Reference. ApplicationXtender Web Access Version 5.3

User s Quick Reference. ApplicationXtender Web Access Version 5.3 ApplicationXtender Web Access Version 5.3 User s Quick Reference EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994-2005 EMC Corporation. All rights

More information

Quick Reference. ApplicationXtender Media Distribution Extraction Wizard 5.30

Quick Reference. ApplicationXtender Media Distribution Extraction Wizard 5.30 ApplicationXtender Media Distribution Extraction Wizard 5.30 Quick Reference EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994-2005 EMC Corporation.

More information

Welcome to VMAX³ Remote Replication Fundamentals.

Welcome to VMAX³ Remote Replication Fundamentals. Welcome to. Copyright 2015 EMC Corporation. All Rights Reserved. Published in the USA. EMC believes the information in this publication is accurate as of its publication date. The information is subject

More information

Additional information about available Support Options as well as other important information can be found by clicking the link found here.

Additional information about available Support Options as well as other important information can be found by clicking the link found here. EMC PRODUCT WARRANTY AND MAINTENANCE TABLE The table below sets forth EMC product-specific warranty and maintenance terms and information. Each product identified as equipment also includes its related

More information

EMC Ionix ControlCenter

EMC Ionix ControlCenter EMC Ionix ControlCenter 6.1 Planning and Installation Guide Volume 2 (MVS Agents) P/N 300-006-363 REV A05 Copyright 2002-2011 EMC Corporation. All rights reserved. Published in the USA. Published August

More information

EMC Ionix ControlCenter

EMC Ionix ControlCenter EMC Ionix ControlCenter 6.1 Performance Manager s Glossary P/N 300-006-360 REV A09 Copyright 2007-2011 EMC Corporation. All rights reserved. Published in the USA. Published August 2011 EMC believes the

More information

Additional information about available Support Options as well as other important information can be found by clicking the link found here.

Additional information about available Support Options as well as other important information can be found by clicking the link found here. DELL EMC PRODUCT WARRANTY AND MAINTENANCE TABLE The table below sets forth DELL EMC 1 product-specific warranty and maintenance terms and information. Each product identified as equipment also includes

More information

Welcome to Symmetrix Fundamentals.

Welcome to Symmetrix Fundamentals. Welcome to. Copyright 1996, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is

More information

Quick Reference. ApplicationXtender Reports Management Extract Definition Script (XDS) 5.30

Quick Reference. ApplicationXtender Reports Management Extract Definition Script (XDS) 5.30 ApplicationXtender Reports Management Extract Definition Script (XDS) 5.30 Quick Reference EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994-2005

More information

EMC VFCache VMware VSI Plug-In

EMC VFCache VMware VSI Plug-In EMC VFCache VMware VSI Plug-In v1.5 Administration Guide P/N 300-014-275 REV A02 Copyright 2012 EMC Corporation. All rights reserved. Published in the USA. Published August, 2012 EMC believes the information

More information

EMC Ionix ControlCenter

EMC Ionix ControlCenter EMC Ionix ControlCenter 6.1 Administrators Guide P/N 300-006-338 REV 15 Copyright 2001-2012 EMC Corporation. All rights reserved. Published in the USA. Published November, 2012 EMC believes the information

More information

VNX Unified Storage Implementation Lab Guide

VNX Unified Storage Implementation Lab Guide VNX Unified Storage Implementation Lab Guide August 2011 EMC Education Service Copyright Copyright 1996, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010., 2011 EMC Corporation. All Rights

More information

Welcome to XtremIO Fundamentals

Welcome to XtremIO Fundamentals Welcome to Copyright 2015 EMC Corporation. All Rights Reserved. Published in the USA. EMC believes the information in this publication is accurate as of its publication date. The information is subject

More information

ESRP Storage Program EMC Celerra NS-120 (1,500 User) Storage Solution for Microsoft Exchange Server 2007 SP1

ESRP Storage Program EMC Celerra NS-120 (1,500 User) Storage Solution for Microsoft Exchange Server 2007 SP1 ESRP Storage Program EMC Celerra NS-120 (1,500 User) Storage Solution for Microsoft Exchange Server 2007 SP1 Tested with: ESRP Storage Version 2.1 Tested Date: 04/28/2009 EMC Corporation Corporate Headquarters

More information

EMC License Server. Installation and Administration Guide Rev 04

EMC License Server. Installation and Administration Guide Rev 04 EMC License Server Installation and Administration Guide 302-002-433 Rev 04 Copyright 2015, EMC Corporation. All rights reserved. Published December, 2015 EMC believes the information in this publication

More information

ESRP Storage Program EMC Celerra NS40 (3,000 User) Storage Solution for Microsoft Exchange Server 2007 SP1

ESRP Storage Program EMC Celerra NS40 (3,000 User) Storage Solution for Microsoft Exchange Server 2007 SP1 ESRP Storage Program EMC Celerra NS40 (3,000 User) Storage Solution for Microsoft Exchange Server 2007 SP1 Tested with: ESRP Storage Version 2.1 Tested Date: 11/18/2008 EMC Corporation Corporate Headquarters

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,000 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,000 User) iscsi Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,000 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/04/07 EMC Corporation Corporate Headquarters

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/06/07 EMC Corporation Corporate

More information

Symmetrix Foundations

Symmetrix Foundations Symmetrix Foundations 2009 EMC Corporation. All rights reserved. Welcome to Symmetrix Foundations. Copyright 2009 EMC Corporation. All rights reserved. These materials may not be copied without EMC's written

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,200 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,200 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,200 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/04/07 EMC Corporation Corporate

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/06/07 EMC Corporation Corporate Headquarters

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,300 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,300 User) iscsi Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,300 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/06/07 EMC Corporation Corporate Headquarters

More information

ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/04/07 EMC Corporation Corporate Headquarters

More information

ESRP Storage Program EMC CX-3-20 (700 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CX-3-20 (700 User) iscsi Storage Solution for Microsoft Exchange Server 2007 White Paper ESRP Storage Program EMC CX-3-20 (700 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 03/21/07 EMC believes the information

More information

ESRP Storage Program EMC CX-3-20 (900 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CX-3-20 (900 User) iscsi Storage Solution for Microsoft Exchange Server 2007 White Paper ESRP Storage Program EMC CX-3-20 (900 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 03/21/07 EMC believes the information

More information

ESRP Storage Program EMC CX-3-20 (1000 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CX-3-20 (1000 User) iscsi Storage Solution for Microsoft Exchange Server 2007 White Paper ESRP Storage Program EMC CX-3-20 (1000 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 03/21/07 EMC believes the information

More information

ESRP Storage Program EMC CX-3-20 (1300 User) iscsi Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CX-3-20 (1300 User) iscsi Storage Solution for Microsoft Exchange Server 2007 White Paper ESRP Storage Program EMC CX-3-20 (1300 User) iscsi Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 03/21/07 EMC believes the information

More information

ESRP Storage Program EMC Celerra NS20 (700 User) Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC Celerra NS20 (700 User) Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC Celerra NS20 (700 User) Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 8/2/2007 EMC Corporation Corporate Headquarters Hopkinton,

More information

ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi with LCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/04/07 EMC Corporation Corporate

More information

ESRP Storage Program EMC Celerra NS20 (1,000 User) Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC Celerra NS20 (1,000 User) Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC Celerra NS20 (1,000 User) Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 8/2/2007 EMC Corporation Corporate Headquarters

More information

EMC Smarts MPLS Manager Innovative Technology for MPLS/VPN Management

EMC Smarts MPLS Manager Innovative Technology for MPLS/VPN Management EMC Smarts MPLS Manager Innovative Technology for MPLS/VPN Management Abstract: Increasingly, both service providers and enterprises are turning to Multi-Protocol Label Switching (MPLS) to combine the

More information

ESRP Storage Program EMC Celerra NS20 (1,500 User) Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC Celerra NS20 (1,500 User) Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC Celerra NS20 (1,500 User) Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 07/24/07 EMC Corporation Corporate Headquarters

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,300 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,300 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,300 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/06/07 EMC Corporation Corporate

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,400 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/06/07 EMC Corporation Corporate

More information

ESRP Storage Program EMC CLARiiON CX3-20c (1,000 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (1,000 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (1,000 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/04/07 EMC Corporation Corporate

More information

ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007

ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 ESRP Storage Program EMC CLARiiON CX3-20c (600 User) iscsi with CCR Storage Solution for Microsoft Exchange Server 2007 Tested with: ESRP Storage Version 2.0 Tested Date: 12/04/07 EMC Corporation Corporate

More information

White Paper. Storage Intelligence in the Network: EMC s Perspective

White Paper. Storage Intelligence in the Network: EMC s Perspective White Paper Storage Intelligence in the Network: EMC s Perspective Date 08/2003 Copyright 2003 EMC Corporation. All rights reserved. EMC believes the information in this publication is accurate as of its

More information

EMC Simple Support Matrix

EMC Simple Support Matrix EMC Simple Support Matrix EMC Enterprise Hybrid Cloud 2.5.1 Federation SDDC Edition SEPTEMBER 2015 REV 07 2014-2015 EMC Corporation. All Rights Reserved. EMC believes the information in this publication

More information

Three Paths To The Cloud. Kirill Kostitsyn

Three Paths To The Cloud. Kirill Kostitsyn Three Paths To The Cloud Kirill Kostitsyn ЕМС full solutions range Data Analytics Primary Storage Backup Enterprise Applications High End Enterprise Mid Range SMB Security Mgmt Federation Big Data Applications

More information

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems

Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems Power Vault in EMC Symmetrix DMX-3 and Symmetrix DMX-4 Systems Applied Technology Abstract This white paper is an overview of Power Vault operation in EMC Symmetrix DMX-3 and Symmetrix DMX-4 environments.

More information

Information Storage and Management

Information Storage and Management Information Storage and Management Storing, Managing, and Protecting Digital Information Edited by G. Somasundaram Alok Shrivastava EMC Education Services W WILEY Wiley Publishing, Inc. Contents Foreword

More information

Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide

Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide White Paper Third-party Information Provided to You Courtesy of Dell Dell/EMC CX3 Series Oracle RAC 10g Reference Architecture Guide Abstract This document provides an overview of the architecture of the

More information

Simple Support Matrix

Simple Support Matrix Version REV 07 January 2018 The following tables provide product compatibility information for Classic. This solution uses English language versions of the applications. interoperability and system limits...2

More information

HP 3PAR OS Messages and Operators Guide

HP 3PAR OS Messages and Operators Guide HP 3PAR OS 3.1.1 Messages and Operators Guide Abstract This guide is for system administrators and experienced users who are familiar with the storage systems, understand the operating system(s) they are

More information

Transforming Storage. An EMC Overview. Sasho Tasevski Sr. Technology consultant

Transforming Storage. An EMC Overview. Sasho Tasevski Sr. Technology consultant Transforming Storage An EMC Overview Sasho Tasevski Sr. Technology consultant sasho.tasevski@emc.com IN 2000 THE WORLD GENERATED TWO EXABYTES OF NEW INFORMATION Sources: How Much Information? Peter Lyman

More information

EMC Innovations in High-end storages

EMC Innovations in High-end storages EMC Innovations in High-end storages Symmetrix VMAX Family with Enginuity 5876 Sasho Tasevski Sr. Technology consultant sasho.tasevski@emc.com 1 The World s Most Trusted Storage System More Than 20 Years

More information

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow

More information

VPLEX Networking. Implementation Planning and Best Practices

VPLEX Networking. Implementation Planning and Best Practices VPLEX Networking Implementation Planning and Best Practices Internal Networks Management Network Management VPN (Metro/Witness) Cluster to Cluster communication (WAN COM for Metro) Updated for GeoSynchrony

More information

Introduction to the CX700

Introduction to the CX700 Engineering White Paper Introduction to the CX700 Abstract This white paper introduces the full 2 Gb architecture and functionality of the CX700 storage system. It compares the features and capabilities

More information

Cloud REDEFINE YOURSELF. Customer Education Catalog NOVEMBER When information comes together,

Cloud REDEFINE YOURSELF. Customer Education Catalog NOVEMBER When information comes together, Cloud REDEFINE YOURSELF Customer Education Catalog NOVEMBER 2015 When information comes together, Plan and Architect Build Your Team of Trusted Advisors Cloud Architect Service Management for ITaaS Enterprise

More information

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA.

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA. This solution guide describes the data protection functionality of the Federation Enterprise Hybrid Cloud for Microsoft applications solution, including automated backup as a service, continuous availability,

More information

Multi-Product Platform Announcement

Multi-Product Platform Announcement 1 Multi-Product Platform Announcement Monday, July 16, 2007 2 Forward-Looking Statements This presentation contains forward-looking statements as defined under the Federal Securities Laws. Actual results

More information

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA.

Copyright 2015 EMC Corporation. All rights reserved. Published in the USA. This Reference Architecture Guide describes, in summary, a solution that enables IT organizations to quickly and effectively provision and manage Oracle Database as a Service (DBaaS) on Federation Enterprise

More information

EMC ProtectPoint. Solutions Guide. Version REV 03

EMC ProtectPoint. Solutions Guide. Version REV 03 EMC ProtectPoint Version 3.5 Solutions Guide 302-003-476 REV 03 Copyright 2014-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2017 Dell believes the information in this publication

More information

EMC FORUM Vic Bhagat. Executive Vice President & Chief Information Officer EMC Corporation

EMC FORUM Vic Bhagat. Executive Vice President & Chief Information Officer EMC Corporation Copyright 20132012 EMC Corporation. EMC Corporation. All rights reserved. All rights reserved. 1 EMC FORUM 2013 Vic Bhagat Executive Vice President & Chief Information Officer EMC Corporation 2 BILLIONS

More information

EMC VSPEX. Proven Infrastructure. P.M. Hashin Kabeer Sr. Systems Engineer. Copyright 2013 EMC Corporation. All rights reserved.

EMC VSPEX. Proven Infrastructure. P.M. Hashin Kabeer Sr. Systems Engineer. Copyright 2013 EMC Corporation. All rights reserved. EMC VSPEX Proven Infrastructure P.M. Hashin Kabeer Sr. Systems Engineer 1 Two Fundamental Challenges 65% MAINTAIN Increase Revenue 35% INVEST Lower Operational Costs Gartner IT Key Metrics Data, December

More information

Parts Location Guide P/N Rev 01

Parts Location Guide P/N Rev 01 EMC VNX Family VNX5100 Parts Location Guide P/N 300-013-312 Rev 01 June 26, 2012 This guide describes one of five models available in the VNX Series, the EMC VNX5100. This guide is a parts location guide

More information

EMC VSPEX. Proven Infrastructure That Is Simple, Efficient, And Flexible. Copyright 2013 EMC Corporation. All rights reserved.

EMC VSPEX. Proven Infrastructure That Is Simple, Efficient, And Flexible. Copyright 2013 EMC Corporation. All rights reserved. EMC VSPEX Proven Infrastructure That Is Simple, Efficient, And Flexible 1 Two Fundamental Challenges 65% MAINTAIN Increase Revenue 35% INVEST Lower Operational Costs Gartner IT Key Metrics Data, December

More information

Exam Name: Technology Architect Solutions Design Exam

Exam Name: Technology Architect Solutions Design Exam Vendor: EMC Exam Code: E20-322 Exam Name: Technology Architect Solutions Design Exam Version: DEMO QUESTION 1 A customer wants to consolidate a large physical IT infrastructure with a VMware vsphere based

More information

Storage Platforms Update. Ahmed Hassanein, Sr. Systems Engineer

Storage Platforms Update. Ahmed Hassanein, Sr. Systems Engineer Storage Platforms Update Ahmed Hassanein, Sr. Systems Engineer 3 4 Application Workloads PERFORMANCE DEMANDING UNDERSTANDING APPLICATION WORKLOADS CAPACITY DEMANDING IS VITAL TRADITIONAL CLOUD NATIVE 5

More information

EMC ViPR Controller. Ingest Services for Existing Environments Guide. Version REV 01

EMC ViPR Controller. Ingest Services for Existing Environments Guide. Version REV 01 EMC ViPR Controller Version 3.5 Ingest Services for Existing Environments Guide 302-003-280 REV 01 Copyright 2013-2016 EMC Corporation. All rights reserved. Published in the USA. Published October 2016

More information

EMC Celerra NS-120 System (Dual Blade) Installation Guide

EMC Celerra NS-120 System (Dual Blade) Installation Guide EMC Celerra NS- System (Dual Blade) Installation Guide P/N -7-88 Rev A EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without

More information

EMC Celerra NS-120 System (Single Blade) Installation Guide

EMC Celerra NS-120 System (Single Blade) Installation Guide EMC Celerra NS- System (Single Blade) Installation Guide P/N 3-7-88 Rev A4 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change

More information

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. 1 This training module is divided in six main chapters.

More information

EMC VPLEX Geo with Quantum StorNext

EMC VPLEX Geo with Quantum StorNext White Paper Application Enabled Collaboration Abstract The EMC VPLEX Geo storage federation solution, together with Quantum StorNext file system, enables a global clustered File System solution where remote

More information

TRANSFORM YOUR APPLICATIONS

TRANSFORM YOUR APPLICATIONS TRANSFORM YOUR APPLICATIONS Virtualizing Your Business Critical Applications Business Drivers Increase Revenue INCREASE AGILITY Lower Operational Costs Reduce Risk CLOUD TRANSFORMS IT Lower Operational

More information

BLOCKBUSTER BACKUP REDESIGN

BLOCKBUSTER BACKUP REDESIGN BLOCKBUSTER BACKUP REDESIGN Markus Fischer BRS Sales Austria 1 Today s Discussion What s Happening in Backup Redesign Market Update EMC Backup and Recovery Solutions 2 Data Protection Software Market Appearance

More information

EMC RECOVERPOINT FAMILY OVERVIEW A Detailed Review

EMC RECOVERPOINT FAMILY OVERVIEW A Detailed Review White Paper EMC RECOVERPOINT FAMILY OVERVIEW A Detailed Review Abstract This white paper provides an overview of EMC RecoverPoint, establishing the basis for a functional understanding of the product and

More information

場次 :B-2 公司名稱 :EMC 易安信電腦 主題 : VSPEX 輕鬆建構完整企業伺服器及桌面虛擬化服務 主講人 : 資深技術顧問吳岱侑

場次 :B-2 公司名稱 :EMC 易安信電腦 主題 : VSPEX 輕鬆建構完整企業伺服器及桌面虛擬化服務 主講人 : 資深技術顧問吳岱侑 場次 :B-2 公司名稱 :EMC 易安信電腦 主題 : VSPEX 輕鬆建構完整企業伺服器及桌面虛擬化服務 主講人 : 資深技術顧問吳岱侑 24% Maybe 10% No 66% Yes A full two-thirds say they have pursued or are pursuing a private cloud computing strategy by 2014. GARTNER

More information

DELL EMC VPLEX FAMILY

DELL EMC VPLEX FAMILY Specification Sheet DELL EMC VPLEX FAMILY Introduction Dell EMC VPLEX enables IT organizations to create a storage architecture that enables a data center to be: Always available even in the face of disasters

More information

Install & Run the EMC VNX Virtual Storage Appliance (VSA)

Install & Run the EMC VNX Virtual Storage Appliance (VSA) Install & Run the EMC VNX Virtual Storage Appliance (VSA) Simon Seagrave EMC vspecialist Technical Enablement Team & Blogger Kiwi_Si simon.seagrave@emc.com 1 Goal of this session In this session I want

More information

Rrootshell Technologiiss Pvt Ltd.

Rrootshell Technologiiss Pvt Ltd. Course Description Information Storage and Management (ISM) training programme provides a comprehensive introduction to information storage technology that will enable you to make more informed decisions

More information

EMC RECOVERPOINT/EX Applied Technology

EMC RECOVERPOINT/EX Applied Technology White Paper EMC RECOVERPOINT/EX Applied Technology Abstract This white paper discusses how EMC RecoverPoint/EX can be used with the EMC Symmetrix VMAX 20K and Symmetrix VMAX 40K with Enginuity 5876 and

More information

Dell EMC ViPR Controller

Dell EMC ViPR Controller Dell EMC ViPR Controller Version 3.6.2 Ingest Services for Existing Environments Guide 302-004-917 Copyright 2013-2018 Dell Inc. or its subsidiaries. All rights reserved. Published June 2018 Dell believes

More information

EMC Forum 2014 EMC ViPR and ECS: A Lap Around Software-Defined Services. Magnus Nilsson Blog: purevirtual.

EMC Forum 2014 EMC ViPR and ECS: A Lap Around Software-Defined Services. Magnus Nilsson Blog: purevirtual. EMC Forum 2014 EMC ViPR and ECS: A Lap Around Software-Defined Services Magnus Nilsson magnus.nilsson@emc.com Twitter: @swevm Blog: purevirtual.eu 1 Session Agenda Market Dynamics EMC ViPR Overview What

More information

N3240 Installation and Setup Instructions

N3240 Installation and Setup Instructions IBM System Storage N3240 Installation and Setup Instructions Covering the N3240 model GA32-2203-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

EMC VPLEX with Quantum Stornext

EMC VPLEX with Quantum Stornext White Paper Application Enabled Collaboration Abstract The EMC VPLEX storage federation solution together with Quantum StorNext file system enables a stretched cluster solution where hosts has simultaneous

More information

Isilon Hardware Basics and Guidelines

Isilon Hardware Basics and Guidelines Isilon Hardware Basics and Guidelines 1. Isilon Hardware Basics and Guidelines 1.1 Isilon Hardware Basics and Guidelines Welcome to the Isilon Hardware Basics and Guidelines course. This course, for EMC

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved.

Copyright 2006 EMC Corporation. Do not Copy - All Rights Reserved. SAN Foundations An Introduction to Fibre Channel Connectivity 2006 EMC Corporation. All rights reserved. Welcome to SAN Foundations. The AUDIO portion of this course is supplemental to the material and

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

N3220 Installation and Setup Instructions

N3220 Installation and Setup Instructions IBM System Storage N3220 Installation and Setup Instructions Covering the N3220 model GA32-2202-01 Notices Mail comments to: IBM Corporation Attention Department GZW 9000 South Rita Road Tucson, AZ 85744-0001

More information

INTRODUCTION TO THE EMC VNX2 SERIES

INTRODUCTION TO THE EMC VNX2 SERIES White Paper INTRODUCTION TO THE EMC VNX2 SERIES A Detailed Review Abstract This white paper introduces the EMC VNX2 series platform. It discusses the different models, new and improved features, and key

More information

MICROSOFT APPLICATIONS

MICROSOFT APPLICATIONS MICROSOFT APPLICATIONS Speed The Journey To Your Virtual Private Cloud 1 Business Drivers Increase Revenue INCREASE AGILITY Lower Operational Costs Reduce Risk 2 Cloud Transforms IT Infrastructure

More information

EMC Forum EMC ViPR and ECS: A Lap Around Software-Defined Services

EMC Forum EMC ViPR and ECS: A Lap Around Software-Defined Services EMC Forum 2014 Copyright 2014 EMC Corporation. All rights reserved. 1 EMC ViPR and ECS: A Lap Around Software-Defined Services 2 Session Agenda Market Dynamics EMC ViPR Overview What s New in ViPR Controller

More information

PROVEN TM PROFESSIONAL CERTIFICATION FRAMEWORK

PROVEN TM PROFESSIONAL CERTIFICATION FRAMEWORK PROVEN TM PROFESSIONAL CERTIFICATION FRAMEWORK A comprehensive education and certification program which develops and validates skills required to advance your career and drive digital transformation.

More information

DNS-2608 Enterprise JBOD Enclosure User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON

More information