1 INSTRUMENT HANDBO DeviceNet VP5 Digital Proportional ontrol Valve To download the product EDS file visit DeviceNet VP5 Manual Ver., 9/0/0

2 Table of ontents. Introduction. Safety 3. Operating Description. Dimensional Details 5. Installation Pneumatic Electrical DeviceNet 6. DeviceNet Interface Details 7. Local User Interface Details 8. E Declaration of onformity 9. ODVA Declaration of onformity. INTRODUTION The DeviceNet VP5 Programmable Digital Proportional ontrol Valve for industrial pneumatic pressure control applications. The DeviceNet VP5 can be configured to meet application requirements. Fluid Output Pressure Range Supply Pressure Flow apacity ontrol Signal Electrical Supply Operating Temperature compressed air 0-50 psig (or 0-0bar) user definable. For applications where the user defined span is less that 50% of maximum (<75psi, 5bar) please consult Norgren. Up to 00psig/bar max 300 l/min/6slfm bit polled output from DeviceNet Powered from DeviceNet (current consumption < 00mA) -0 to 50 (ambient) Warranty A two year warranty applies to all Norgren products. For terms and conditions ask for a copy of our General onditions of Sale.. SAFETY ompressed air in its basic state or in its more sophisticated applied forms can result in accidents if it is not properly used. We therefore draw your attention to the following paragraphs*: The Health and Safety at Work Act (97) makes specific requirements on suppliers and users. To conform with these requirements IMI Norgren Ltd. has, so far as it is reasonably practicable, designed, constructed and tested its products so as to be safe when properly used. Many of our customers, being suppliers as well as users, are reminded of the imposed duties of the above Act and when expediting these duties our technical staff will be pleased to advise. We cannot accept responsibility for the design of plant which might use our equipment and would recommend the use of European Norm (EN) standards and BS 575:Part 3 (988), (Note compliance with these standards does not in itself confer immunity from legal obligation). We also suggest the guidance booklet by the Health and Safety Executive HS(G)39, ompressed Air Safety that offers advice on the safe use of compressed air.

3 3. OPERATING DESRIPTION The DeviceNet VP5 is a programmable electronic proportional control valve. The pneumatic section is a diaphragm actuated precision glandless spool valve, pilot pressure applied to the pneumatic section controls the output pressure of the unit. The pilot pressure is generated and controlled electronically. The feedback signal from the outlet port is compared to the control signal required and ensures a consistent, stable output pressure. The electronics system requires a nominal V D supply signal (supplied from DeviceNet). With a 50 psi standard unit, the user can define their requirements through DeviceNet parameters, and set the application parameters needed for the unit, i.e. speed, proportional & integral gain, thresholds etc.. DIMENSION DETAILS =Inlet Port =Outlet Port 3=Exhaust Port 3

4 5. INSTALLATION Pneumatic Installation Supply Pressure: 5psig above maximum output required (00psig max.) Output Pressure Range: 0-50psig Media: clean, dry 5µ filtered air Porting: G/; /NPT; ISO Manifold Mount Use oil-free air Do not use PTFE tape G/ & /NPT variants Exhaust port (3) Supply port () Electrical connector 3 Return spring housing. Do not adjust. Output port () onnect pipe-work using 0mm OD, 8mm ID, plastic pipe, cut cleanly at right angles, with push-fit pipe connections. Fit an exhaust silencer to Port 3 if required (this will only slightly degrade exhaust performance) ISO Manifold Mount variant Exhaust port (3) Supply port () Output port () Exhaust port (3) Electrical connector Return spring housing. Do not adjust. Output port () ISO- sub base mounting holes Supply port () Use grub screws provided to plug cross drilled holes in interface plate Mount interface plate to ISO- sub base with four M6 screws, with gasket between plate and sub base. Place three O-rings in three counterbored holes in plate and mount VP5 with two M screws. VP5 mounting holes (M tapped) x Electrical Installation onnect the unit as follows using DeviceNet approved screened cable and a M female connector or with a ready made M DeviceNet cable: Pin : Pin : Pin 3: Pin : Pin 5: Drain (bare) V+ (red) V- (black) AN_H (white) AN_L (blue) 5 3 onnector pinout looking onto the end of the instrument

5 DeviceNet Installation Download the DeviceNet VP5 EDS file from Register the EDS file using a DeviceNet configuration tool (e.g. Rockwell RSNetworx). The device MAID and baud rate are factory set to address 63 and Autobaud (see notes & ). onnect the DeviceNet VP5 to a DeviceNet network. Use the keypad or your DeviceNet configuration tool to change the MAID and baud rate parameters as required. Map the polled i/o to a DeviceNet master device (e.g. PL scanner). ontrol the pressure by polling the polled input Demand Pressure over the range (=0-05% of output pressure range). Use a DeviceNet configuration tool (e.g. Rockwell RSNetworx) to change the DeviceNet VP5 parameters to suit the application (see note 3). Notes: ) MAID - The DeviceNet VP5 MAID is factory set to 63. Once the DeviceNet VP5 is powered, this can be changed either over the DeviceNet network or using the instrument s keypad. If the DeviceNet VP5 detects that another device on the network already has its MAID, it will display a Set Node Address message instructing you to change the its MAID using the keypad. See section 7 of this manual for more details. ) Baud rate - The DeviceNet VP5 is factory set with Autobaud detection. This means that it listens to the network, detects the baud rate and selects its own baud rate accordingly. In order for this to work, it is necessary for the DeviceNet network to already have two or more other devices actively communicating on the network. After successful Autobaud detection, the baud rate parameter automatically switches to the selected baud rate. To run the Autobaud function again, the baud rate setting must be changed back to Autobaud via the keypad or DeviceNet. If Autobaud detection is unsuccessful or if the instrument has previously been set to an incorrect baud rate, it will automatically display a Set Baud Rate message instructing you to change the baud rate using the keypad. See section 7 of this manual for more details. 3) ADR facility - The DeviceNet VP5 supports ADR (Automatic Device Recovery). If the PL has been configured to provide this feature and a DeviceNet VP5 is replaced with a new one, the PL will automatically detect the new one and configure its address and parameters to be the same as the device it is replacing. Refer to the PL and DeviceNet configuration tool instructions for more details. 5

6 6. DEVIENET INTERFAE DETAILS I/O Data Name I/O Type (see Note ) No. Bytes Format Demand Pressure Polled Output bit integer (0 to 095) 0 = minimum (zero) pressure 095 = full scale output + 5% span (see Note ) Actual Pressure Polled Input bit integer (0 to 095) 0 = minimum (zero) pressure 095 = full scale output + 5% span (see Note 3) Status Byte Polled Input Bit 0: Set if difference between Demand Pressure and Actual Pressure exceeds Error Limit (see parameter 0). Bit : Set if Bit 0 has been set for longer than Error Delay (see parameter ). Bit : Set if Actual Pressure Threshold A (see parameter ). Bit 3: Set if Actual Pressure Threshold B (see parameter 3). Bits -7: Not used. (See Note 3) Notes: ) Inputs and Outputs are defined from the perspective of the DeviceNet network. ) For 50 psi variant Demand Pressure value= 6 x (Required Pressure in psi), e.g. to output 00 psi, set Demand Pressure value to 600. For 0 bar variant Demand Pressure value = 390 x (Required Pressure in bar), e.g. to output 6 bar, set Demand Pressure value to 30. IMPORTANT - Only of the 6 bits in the two Demand Pressure bytes are used. The four most significant bits are ignored. Setting the Demand Pressure value above 095 or below 0 may lead to unpredicted output pressures. 3) If the polled input is read as a single value of 3 or more bytes, the two least significant bytes hold the actual pressure and the third least significant is the status byte. For example, a returned value of 660 (0x00F3) represents an actual pressure of 0x0F3 = 3900 = 00% full scale and a status byte of 0x0 = bit set. DeviceNet Parameters The following parameters are available via a DeviceNet configuration tool (e.g. RSNetworx) or via DeviceNet explicit messaging, using the class, instance, attribute and byte length details in the table. To use a DeviceNet configuration tool, it is necessary to register the DeviceNet VP5 EDS file on the configuration tool. The EDS file can be downloaded from Parameter No. Name Format Default Value lass Instance Attribute Byte length Baud Rate Selectable from: Autobaud 3 Autobaud, 5Kb/s, 50Kb/s, 500Kb/s (see note ) Serial Read only byte integer Factory 6 number set 3 Demand Pressure Read only integer, = minimum (zero) pressure 095 = full scale output + 5% span (same as polled output, see note ) - 3 (0x7) 6

7 Parameter No. Name Format Default Value lass Instance Actual Read only integer, Pressure 0 = minimum (zero) pressure (0x0D) 095 = full scale output + 5% span (same as polled input) 5 Status Read only byte (same as Byte polled input) 6 Speed Selectable integer, = fastest, 7 = slowest See fig. 7 Prop Gain Selectable integer = low gain, 7 = high gain (see note 3) See fig. 3 8 Int Gain Selectable integer = low gain, 7 = high gain (see note 3) See fig. 3 9 Dither Amplitude Selectable integer = no dither, 7 = maximum dither 0 Error Limit Selectable 0=05% (0-095) 0 = Error Limit Off 05% = Full scale output + 5% Error Delay Integer Set in 00ths of a second Threshold Selectable 0-05% (0-095) A 0 = Status Bit always set 3 Threshold B Pressure Units 5 Signal Failure Mode 05% = Full scale output + 5% Selectable 0-05% (0-095) 0 = Status Bit 3 always set 05% = Full scale output + 5% Selectable from: Bar, psi, kpa, Atm, kg/cm^ Sets units for pressure display on LD Selectable from Fail Safe, Fail Freeze Sets operation of device on loss of polled signal from network (see note ). Attribute Byte length 3-3(0x0D) (0x68) 3 05 (0x69) 3 06 (0x6A) 3 07 (0x6B) 0% (390) 00 ( secs) 50% (950) 00% (3900) Depends on part number 3 09 (0x6D) 3 0 (0x6E) 3 (0x6F) 3 (0x70) 3 08 (0x6) Fail Safe 3 3 (0x7) Notes: ) If the baud rate parameter is set to Autobaud the Device will automatically listen to the network and work out the correct baud rate. The baud rate parameter will then automatically be set to the appropriate baud rate and will remain at its new setting even after removing power from the Device. In order to run the Autobaud function again, the baud rate must be changed back to Autobaud via DeviceNet or via the keypad. ) Demand Pressure can only be set by means of a polled I/O message. It can be read but not set by explicit messaging. If no polled message is received, the output pressure is set according to parameter 5 Signal Failure Mode. If Fail Safe is selected, the output pressure will be zero when no polled messages are being received. If Fail Freeze is selected, the output pressure will remain at its last set value when no polled messages are being received. 3) To set the proportional gain, first set the integral gain to 0, then adjust the proportional gain to give the best possible response time without causing unacceptable overshoot or oscillations. Once proportional gain is set correctly, increase integral gain to achieve the best possible accuracy without causing unacceptable hunting (slow oscillations) on the output. See figs & 3. 7

8 Fig. - Speed Setting Effects at default Proportional and Integral Gain 0 Pressure, bar Time Fig. - Proportional Gain Effects at default Integral Gain and Speed 0 Pressure, bar Time 0. Fig. 3 - Integral Gain Effects at default Proportional Gain and Speed 0. Pressure, bar Time 8

9 7. LOAL USER INTERFAE DETAILS The DeviceNet VP5 includes an integral keypad and LD display. During normal operation, this will display the current output pressure of the instrument and its DeviceNet MAID (node address number). The keypad can be used to locally set the device MAID and baud rate. The complete menu structure is shown in fig.. Device goes online correctly xxx. psi Node xx Password **** Set-up omms DN Set Baud Autobaud xxx / Set Node xx / Reset : ycle Pow.. UP hange Password DN UP New **** onfirm **** Help com Incorrect baud rate or Autobaud fails Set Baud Rate Password **** Set Baud xxx Duplicate node address detected Set Node Address Password **** Set Node xx Reset : ycle Pow.. Figure Local User Interface Menu Structure 9

10 hanging MAID or Baud Rate From Normal Operating Mode When the Device is in normal operating mode (i.e. communicating on DeviceNet), the baud rate or MAID can be changed by following the steps detailed below: Press from the default screen to enter the user interface. Enter the password using the numbered arrow keys (see section on Password below). Press to enter the Set-up omms menu. Use the up and down arrows to select the required baud rate and press to accept. Alternatively, press to skip this stage or cancel changes to the baud rate. Use the up and down arrows to select the required MAID (node address) and press to accept. Alternatively, press to skip this stage or cancel changes to the MAID. If either the baud rate or the MAID have been changed, a message will be displayed reading Reset: ycle Power to Activate ancel to Abort. In order for the new settings to become active, the DeviceNet VP5 must be reset. This should be done either by disconnecting and reconnecting the device, or cycling the network power. Alternatively, press to return to the previous settings. From Baud Rate Fault ondition If the baud rate is incorrect or the Autobaud routine has not succeeded, the DeviceNet VP5 display will automatically switch to display the message Set Baud Rate. Under these circumstances, following the steps below: Press to enter the user interface. Enter the password using the numbered arrow keys (see section on Password below). Use the up and down arrows to select the network baud rate and press to accept. Use the up and down arrows to change the MAID (node address) if required, and press to accept. The message will be displayed reading Reset: ycle Power to Activate. In order for the new settings to become active, the DeviceNet VP5 must be reset. This should be done either by disconnecting and reconnecting the device, or cycling the network power. From Node Address fault condition If the DeviceNet VP5 detects that another device on the network already has its MAID (node address), it will automatically switch to Set Node Address. Under these circumstances, following the steps below: Press to enter the user interface. Enter the password using the numbered arrow keys (see section on Password below). Use the up and down arrows to change the MAID (node address) and press to accept. The message will be displayed reading Reset: ycle Power to Activate. In order for the new settings to become active, the DeviceNet VP5 must be reset. This should be done either by disconnecting and reconnecting the device, or cycling the network power. User Interface Password Entry into the local user interface is password controlled to prevent unauthorised access. All standard DeviceNet VP5s are shipped with the password disabled. In this case, press from the password screen to enter the user interface. To change the Password, enter the user interface and use the up and down arrows to select the hange Password menu. Press then enter and confirm the new password the password can be any combination of up to four digits in the range to, entered using the numbered arrow keys. In case the password is forgotten, there is an override facility from the password screen, press and hold down then press and hold down, whilst keeping held down. Hold down both until the user interface is entered (approx. 5 secs). 0

11 8. E DELARATION OF ONFORMITY The DeviceNet VP5 Digital Proportional Valve complies with the E Pressure Equipment Directive and the generic EM standards. BS EN : 00 Electromagnetic ompatibility Part 6- Generic Standard Emission standard for industrial environments BS EN : 999 Electromagnetic ompatibility Part 6- Generic Standards Immunity for industrial environments 9. ODVA DELARATION OF ONFORMITY

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

SPCH/ Big bottle blowing block

SPCH/ Big bottle blowing block > > Blowing block for linear and rotating blow moulding machines > > Digital position indicator - counter with four decade from 000.0 to 00.0 > > Best suited for PET bottles from 5 up to 30 litres (up

More information

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil

More information

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

MPCR Series DeviceNet Technical Manual

MPCR Series DeviceNet Technical Manual MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as

More information

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder speed control

More information

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to

More information

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves 970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

Technical features. 12/ f. N/en

Technical features. 12/ f. N/en /, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integd mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up by automatic

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual K0 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual Pneumatic Connection Single Acting Actuator (Spring Return): For single acting actuators Outlet Port 2 is to be plugged. Outlet Port

More information

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display VP Process Inc. Model: Modbus RTU LCD Display User Manual Ver: 2.0 Aug. 2017 P a g e 1 Standard Features Low Power (12-24 VDC) 2.1 x 5mm Barrel Plug, RJ45 and Terminal Block Input On-Board Local Temperature

More information

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

Operating instructions valve control box AS-i

Operating instructions valve control box AS-i THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive

More information

Technical features. N/en

Technical features. N/en /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way

More information

DeviceNet PCI Card Instructions Manual

DeviceNet PCI Card Instructions Manual Motoman NX100 Controller DeviceNet PCI Card Instructions Manual Part Number: 151799-1CD Revision: 0 Motoman, Incorporated 805 Liberty Lane West Carrollton, OH 45449 TEL: (937) 847-6200 FAX: (937) 847-6277

More information

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve SCV0, SCV0, SCV & SCV, / > > Port size: /4, /, /4 and (ISO G, NPT) > > Range of sizes - DN, 0, and > > Redundant valve assembly, pneumatic self monitoring with integrated safety silencer > > Ensures safe

More information

26360, NAMUR. Technical data

26360, NAMUR. Technical data 66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual

More information

21023, 21025, 2/2 Direct solenoid actuated poppet valves

21023, 21025, 2/2 Direct solenoid actuated poppet valves 03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international

More information

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 Short Guide BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 Short Guide English 1 2 3 4 Notes to the User 3 1.1 About this guide 3 1.2 Structure of the guide 3 1.3 Typographical

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

G3 Series DeviceNet TM Technical Manual

G3 Series DeviceNet TM Technical Manual G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves 9705 Inline, 3/ & 5/ > > : /... / (ISO G/NPT) > > Main application: single and double operated actuators > > Valves for safety systems multi-channel up to SIL 3 > > Crossover-free switching > > TÜV-approval

More information

Pneumatic positioning module contiuous kpa output signal, with manual operation

Pneumatic positioning module contiuous kpa output signal, with manual operation 8 167 DEIGO I/O modules Pneumatic positioning module contiuous 0...138 kpa output signal, with manual operation Electro-pneumatic signal converter for connection to P-bus, output with a continuous control

More information

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

Instruction and Operation Manual

Instruction and Operation Manual SEC IR PC LINK Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 email sensor@minn.net or www.sensorelectronics.com

More information

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT direct pneumatically actuated 3/ and 5/ spool valves G /.G/, / NPT / NPT For single and double operated actuators Valves for safety systems up to SIL () Crossover-free switching, switch-over function guaranteed

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple

More information

BNI DNT Z001 DeviceNet IO-Link Master User s Guide

BNI DNT Z001 DeviceNet IO-Link Master User s Guide BNI DNT-52-1-Z1 DeviceNet IO-Link Master User s Guide Contents 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

Installing Keypad and Backplate

Installing Keypad and Backplate Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 57 Individual mounting Series inline 35 To accumulator Sealed solenoid enclosure 100 200 Ext. pilot port Pilot valve Function plate From accumulator

More information

PNEUFIT 10 series Push-in fittings

PNEUFIT 10 series Push-in fittings PNUFIT 0 series > > Port size: Ø 4... 4 mm O/D tube, SP threads > > Very compact units > > asy tube insertion for rapid assembly of pneumatic circuits > > Straight adaptors feature internal hexagon for

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 59 Individual mounting Series inline 35 100 Ext. pilot port Accumulator EXH. Pilot valve Function plate From accumulator Pilot exhaust To accumulator

More information

FieldServer FS DeviceNet Master Adapter Driver

FieldServer FS DeviceNet Master Adapter Driver FieldServer FS-8700-114 DeviceNet Master Adapter Driver Driver Manual (Supplement to the FieldServer Instruction Manual) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after March 2017.

More information

Quick Start Guide and Health and Safety Information

Quick Start Guide and Health and Safety Information D397-10-880 Issue F Original Quick Start Guide and Health and Safety Information Turbo Instrument Controller (TIC) Description TIC Instrument Controller 3 Gauge TIC Instrument Controller 6 Gauge TIC Instrument

More information

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS Operating Instruction for Turbine-wheel Flow Meter Model: DRS . Contents. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection...

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8691 can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

80265 series, 3/2 Indirect solenoid actuated poppet valve

80265 series, 3/2 Indirect solenoid actuated poppet valve > > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,

More information

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

Pressure sensors SPAN

Pressure sensors SPAN Features At a glance Communication interface Convenient design Compact design 30x30 mm Degree of protection IP40 Reduced weight with QS4 Universal pressure measurement Pressure and vacuum 13 pressure measuring

More information

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated ICOS - /, / or / poppet valves > > Port size: /... / (ISO G / NPT) Namur or manifold > > Control of pneumatic or hydraulic operated equipment > > Direct acting solenoid valve > > High flow > > bar inlet

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment.

SQ405 Controller CAUTION. The caution messages are displayed before procedures which, if not followed, could cause damage to the equipment. 87-900-112-01 (A) April 18th, 2011 INSTRUCTIONS SQ405 Controller GENERAL INFORMATION This equipment is destined for use by professionals. The user should read this instruction manual and any other additional

More information

DeviceNet Adapter. 20-COMM-D FRN 1.xxx. User Manual

DeviceNet Adapter. 20-COMM-D FRN 1.xxx. User Manual DeviceNet Adapter 20-COMM-D FRN 1.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

More information

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation User Manual 1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's

More information

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4 OPERATION MANUAL E/P REGULATOR MODEL NAME ITV*0*0 *0*0-DE**** series Series For DeviceNet TM CONTENTS TM Contents Safety Instructions P1 P2 Precautions for Handling P3-4 Wiring and LED display P5-6 Mounting

More information

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application P30-2 Pressure Transmitter Datasheet At a Glance *High Quality* 3 Years Warranty Premium Pressure Transmitter for gauge and pressure measurement with 3 years warranty High repeatability and long-term stability

More information

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled ICO4S /, / or 5/ poppet valves > > Port size: /4... /4 (ISO G/NPT) or manifold version > > Reliable and long life, ideal for a one time installation > > Direct acting solenoid valve for the control of

More information

INSTALLATION INSTRUCTIONS 07/2018

INSTALLATION INSTRUCTIONS 07/2018 INSTALLATION INSTRUCTIONS 1 07/2018 SAFETY AND PROPER USAGE To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed herein. Non-compliance with

More information

21D Allfluid pressure switch, electromechanically actuated

21D Allfluid pressure switch, electromechanically actuated D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 55 Individual mounting Series inline 35 Sealed solenoid enclosure Manual operator 100 200 Ext. pilot port Ext. pilot Pilot filter Pilot exh. 55

More information

BNI DNT Z001. DeviceNet IO-Link Master User s Guide

BNI DNT Z001. DeviceNet IO-Link Master User s Guide BNI DNT-52-1-Z1 DeviceNet IO-Link Master User s Guide Contents 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical conventions 3 Enumerations 3 Actions 3 Syntax 3 Cross-references

More information

60 series, 2/2 or 3/2 Ball valve

60 series, 2/2 or 3/2 Ball valve >> Port size: Rp/..., /... >> Ideally suited for most general purpose applications >> Easy installation, simple operation and maintenance free >> -way ball valves with actuator interface conforming to

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact stainless

More information

Druck DPI bar g. GE Infrastructure Sensing. Pressure Indicator User manual - K344

Druck DPI bar g. GE Infrastructure Sensing. Pressure Indicator User manual - K344 GE Infrastructure Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 150 Pressure Indicator User manual - K344 20.000 FS H T settings Indicator 12.875 bar

More information

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05 Sigma DeviceNet Tool Change Systems USER S GUIDE 94018 Rev 05 648 Saratoga Road Glenville, NY 12302 USA Phone: 518 384 1000 Fax 518 384 1200 www.arobotics.com 1. PRECAUTIONS 1 Sigma DNET Module 1 2.0 DNET

More information

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner GS400 Electronic Auto-Ranging DIN Panel Mounted Positioner Features * AC (115/230V) and DC (24V) versions available. * Accepts either current or voltage command signal and either current, voltage, or three

More information

D Issue A. Instruction Manual. Active Strain Gauge

D Issue A. Instruction Manual. Active Strain Gauge Instruction Manual D357-35-880 Issue A Active Strain Gauge Description ASG2-1000-1/8 NPT ASG2-1000-NW16 ASG2-2000-1/8 NPT ASG2-2000-NW16 Item Number D357-35-000 D357-36-000 D357-37-000 D357-38-000 Declaration

More information

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/ Operating manual Series 450 Compact thermometer BA01235O/09/en/01.13 71220279 2 Table of contents 1 Safety instructions... 3 2 Installation... 4 3 Wiring overview... 7 4 Commissioning... 7 5 Operation...

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

Service unit combinations MSE6, MSE series

Service unit combinations MSE6, MSE series Key features Overview Product description The MSE6-E2M is an intelligent pneumatic service unit for optimising the use of compressed air as an energy medium in industrial automation technology. Equipped

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

CT-1000 Leak Test System. Installation and Operation Manual

CT-1000 Leak Test System. Installation and Operation Manual CT-1000 Leak Test System Installation and Operation Manual Table of Contents Page CT-1000 LEAK TEST SYSTEM 2 OPERATION OVERVIEW 5 SETUP MODE 7 CALIBRATION MODE 12 TEST MODE 16 PNEUMATIC CONNECTIONS 19

More information

DEVAR Inc. Model d-rtti User Manual

DEVAR Inc. Model d-rtti User Manual DEVAR Inc. Model d-rtti User Manual Introduction The Model d-rtti is a room temperature indicator/transmitter that provides an accurate indication of ambient temperature with a numeric readout and a 4

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E... Operating Instructions for Low Volume Rotating Vane Flow Meter Model: DPL-1P... DPL-1V... DPL-1E... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating

More information

FAIRCHILD MODEL T1750 SERIES ELECTRO-PNEUMATIC TRANSDUCERS (Analog Output) Operation and Maintenance Instructions Software Version 3.45 and 3.

FAIRCHILD MODEL T1750 SERIES ELECTRO-PNEUMATIC TRANSDUCERS (Analog Output) Operation and Maintenance Instructions Software Version 3.45 and 3. FAIRCHILD MODEL T1750 SERIES ELECTRO-PNEUMATIC TRANSDUCERS (Analog Output) Operation and Maintenance Instructions Software Version 3.45 and 3.46 Figure 1. Model T1750 Keypad SPECIFICATIONS Figure 2. Model

More information

X38 Series 38mm Laser Trackball, Panel Mount, Protocol Output

X38 Series 38mm Laser Trackball, Panel Mount, Protocol Output X38 Series 38mm Laser Trackball, Panel Mount, Protocol Output 1. DESCRIPTION Utilizing the latest and most advanced laser tracking technology, the X38 Series laser Trackerball is an extremely high specification,

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated

More information

LB74G - EXCELON Modular System General purpose filter/regulator

LB74G - EXCELON Modular System General purpose filter/regulator LBG - EXCELON Modular System > Port size: /... / (ISO G/PFT) > Push to lock adjusting knob with optional tamper resistant accessory > Excelon design allows in-line installation or modular installation

More information

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder

More information

size size

size size BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

Flow. (l/min) (ms) N/en

Flow. (l/min) (ms) N/en 66, 87 Inline / & / spool valves electromagnetic actuated, indirectly controlled G / & G / For single and double operated actuators Manual override with and without detent imple design of soft seal spool

More information