MultiTrode MTIC & MTRIC. Indicator & Remote Indicator Controllers

Size: px
Start display at page:

Download "MultiTrode MTIC & MTRIC. Indicator & Remote Indicator Controllers"

Transcription

1 MultiTrode MTI & MTRI Indicator & Remote Indicator ontrollers

2 Page of 6 MTI / MTRI Manual R

3 MTI Indicator ontroller Four ctuation elays: Method of Operation: Used to average out wave action and for other control functions. The MultiTrode MTI liquid level monitoring and control system was developed to provide a solution for interfacing to building management systems and town water/sewerage systems. The system can directly control operation of pumps and provide level indication at the site, as well as at up to four remote locations, using 0-0V or -0m current loop. Until the advent of this MultiTrode system, these facilities had not been economically practical for hydraulic services in high-rise buildings. MTRI Remote Indicator ontroller ontinuous Level Indication: Using a high-intensity, 0-segment LE bar-graph. 0 Relay Outputs: Enabling control of multiple pumps, alarms and other devices. Level Selection: Variable Speed rives: Remote Indication and ontrol: Four Sensitivities: Simple level selection and adjustment without entering pit or tank. an be controlled via -0m or 0-0V output. -0m or 0-0V outputs will operate MultiTrode Remote Indicator ontroller up to a distance of several miles. Enable the system to operate effectively in a wide range of conductive liquids MTI & MTRI Installation & Operation Manual Revision.0 February 00 MULTITROE and MULTISMRT are registered trademarks of MultiTrode Pty Ltd in ustralia, US, and Europe. PUMPVIEW is a registered trademark of MultiTrode Pty Ltd in the US and ustralia. esigns registered for the MultiSmart Pump ontroller Remote and ase Modules in ustralia, US, Europe and hina. Patents pending in ustralia, US, and Europe. 00 MultiTrode Pty Ltd. This publication is protected by copyright. No part of this publication may be reproduced by any process, electronic or otherwise, without the express written permission of MultiTrode Pty Ltd. MTI / MTRI Manual R Page of 6

4 ontents Introduction.... Front Panel... Function IP Switches Timer & Sensitivity IP Switches Output Relay IP Switches.... Probe Inputs.... Output Relays.... nalog Output Power Supply Terminals & Ratings Label... 8 Installation & Power-Up... 8 Mounting... Electrical onnections.... Probe Inputs.... Output Relays.... nalog Output Power onnection MTI Pump Station Schematic & Overview... 0 MTI Installation Sheet No..... Time elay & Sensitivity Settings... 8 MTI Installation Sheet No.... MTRI Installation Sheet No MTRI Installation Sheet No.... Page of 6 MTI / MTRI Manual R

5 Introduction The MTI is a conductive liquid level indicator and controller which continuously monitor liquid level in order to control the operation of up to 0 appliances. It will work in the following modes: Fill (harge) mode: Filling a tank Empty (ischarge) mode: Emptying a tank In a standard installation, the liquid level is sensed via a MultiTrode multi-sensored probe. Individual sensors can be used in installations, if desired. Ten output relays control pumps, valves and, in addition, there are -0m and 0-0V stepped analogue outputs for use with variable speed drives, chart recorders etc. n MTRI can also be connected to the -0m output of the MTI to remotely indicate level, and control appliances at a distance of up to several kms from the MTI. front-panel LE indicator lamps show level and power supply status. The front panel allows for placement of labels to indicate at which point devices will activate. -way IP switch on the rear panel provides for the setting of four sensitivities and four time delays. In addition, a 0-way IP switch allows for the setting of the relays as Normally Open or Normally losed.. Front Panel MULTITROE INITOR ONTROLLER HI LRM STNY LG LE PUMP OFF LO LRM MTI POWER ON The MTI has LE s. The bar graph on the lefthand side indicates level, whilst the green LE in the upper right-hand corner indicates power availability. There is a slot located next to the bar-graph, that is used for the placement of labels to indicate at what levels pumps and alarms operate. Up to 0 labels can be placed here. Figure - MTI Indicator ontroller Front Panel see fig # OUTPUTS + V - 0-0V -0m 0V N MTI S/N: E 0V 0/60Hz MINS POWER see fig # SELET FUNTION see fig # NO ON ON N see fig # PROE INPUTS The MTI rear panel (see Figure ), contains the terminals, as well as function IP switches, used to preset the unit's basic operations. This section describes the function of each terminal and IP switch. Figure - MTI Indicator ontroller ack Panel MTI / MTRI Manual R Page of 6

6 Function IP Switches n important step in the commissioning of the controller is to preset the positions of the rear panel IP switches. This will set up the basic operation of the unit to match the installation. The following tables show the switch functions.. Timer & Sensitivity IP Switches This section of the back panel is black. see fig # SELET FUNTION Figure The MTI should be switched off prior to altering the IP switch settings. SW Function Position escription Timer Instantaneous actuation when level reaches sensor. Timer Time delay on actuation approx. seconds. Timer Time delay on actuation approx. 0 seconds. Timer Time delay on actuation approx. seconds. Extra low sensitivity KΩ For concentrates such as acids, minerals, alkalis leaving residue. Normal low sensitivity KΩ cids, alkalis, diluted brine, sea water. Normal sensitivity 0KΩ Sullage, sewage effluent, town water. High sensitivity 80KΩ Effluent and processes with oil contaminants, purified water. NOTE: onductance may vary from liquid type as described above. djust sensitivity as required. Page 6 of 6 MTI / MTRI Manual R

7 . Output Relay IP Switches This section is black in colour on the rear panel. SELET FUNTION see fig # Figure Output Relay IP Switches Setting a IP switch to the left or right makes the corresponding output relay act as a normally closed or normally open contact under the following condition: Power is supplied to the unit and no liquid covers the corresponding sensor.. Probe Inputs This section is blue in colour on the rear panel. see fig # Figure Probe Inputs MultiTrode probe would be the normal method of level detection. onnection of ball floats is also accomplished via these terminals, although this is not recommended for reliable level detection. PROE INPUTS. Output Relays This section is white in colour on the rear panel. see fig # OUTPUTS Figure 6 Output Relays 0 programmable contacts allow for the switching of contactors or other equipment. Each relay is rated at 0V mp resistive or mp inductive. The operation of the devices is controlled by level switch points hardwired to the appropriate output relay. This sets the levels at which the devices activate and de-activate. MTI / MTRI Manual R Page of 6

8 . nalog Output This section is white in colour on the rear panel. see fig # Figure nalog Output The analogue outputs supply -0m and 0-0V. It must be noted that these outputs are non-isolated. Various wiring configurations allow for -0m loads up to 0 W. UTION: Under no circumstances connect 0 volts to mains earth..6 Power Supply Terminals & Ratings Label This section is red in colour on the rear panel. 0V 0/60Hz Figure 8 Power Supply Terminals ratings label is located above the supply terminals and power is supplied through these terminals. ctive, Neutral and Earth are connected to their respective terminals as marked. MINS POWER Installation & Power-Up OUTPUTS see fig # see fig # see fig # MTI S/N: + V - 0-0V -0m 0V N E 0V 0/60Hz MINS POWER SELET FUNTION see fig # NO ON ON N PROE INPUTS Figure - MTI Indicator ontroller ack Panel efore attempting to install the MTI/MTRI read this section thoroughly. heck the power rating label above the power input terminals (see drawing below). Make sure that the power supply configuration is compatible with the installation being carried out. Page 8 of 6 MTI / MTRI Manual R

9 Mounting Mount the MTI into a.0mmx.0mm hole (see drawing). The clamp brackets will allow installation into panels up to 8mm (absolute max.) thickness. 8mm mm mm mm PNEL UT OUT EMENSIONS mm 0mm PLN ( TOP VIEW ) UT OUT ELEVTION ( TOP VIEW ) Figure 0 Plan and elevation views of the MTI Slide the controller in from the front of the panel. Insert the two clamp brackets into the double slots in the top and bottom of the case (see drawing). Tighten the screws sufficiently to hold unit. NOTE: Over-tightening will deform the clamps. Electrical onnections see fig #. Probe Inputs This section is blue in colour on the rear panel. onnect the cables from the MultiTrode probe to the corresponding input terminals. Figure Probe Inputs. Output Relays PROE INPUTS ll output relays should be protected by an 8 amp (max.) fuse. There are 0 isolated relay outputs which can be selected N/O or N/ via IP switches to 0. Select outputs which coincide with the desired level on the probe where control is required. s the MTI does not latch each central point, this needs to be achieved using "hold in" contacts on the contactor, as per following example: Hi larm on at Standby on at, off at uty on at, off at 8 uty on at 6, off at 0 Figure Output Relays MTI / MTRI Manual R Page of 6

10 . nalog Output This section is white in colour on the rear panel. see fig # Figure nalog Output s can be seen by the diagram the MTI can drive into a maximum 0W if connected as shown. It should be noted that the analogue output is non-isolated and in certain circumstances will require a loop isolator.. Power onnection This section is red in colour on the rear panel. 0V 0/60Hz MINS POWER Figure Power onnections Prior to connecting the power to the controller, the following checks should be performed:. heck the controller voltage rating to ensure compatibility.. heck that the function IP switches have been set for the correct defaults. onnect as follows:- = ctive N = Neutral E = Earth 6 MTI Pump Station Schematic & Overview MTI STTION OVERVIEW ** ** Figure - MTI Station Overview Page 0 of 6 MTI / MTRI Manual R

11 MTI Schematic Figure 6 - MTI Schematic MTI / MTRI Manual R Page of 6

12 MTI Installation Sheet No. Figure - MTI Layout. Time elay & Sensitivity Settings SW Function Position escription Timer Timer Timer Timer Extra low sensitivity KΩ Normal low sensitivity KΩ Normal sensitivity 0KΩ High sensitivity 80KΩ Figure 8 ip Switch settings sensitivity and time delay. Instantaneous actuation when level reaches sensor. Time delay on actuation approx. seconds. Time delay on actuation approx. 0 seconds. Time delay on actuation approx. seconds. For concentrates such as acids, minerals, alkalis leaving residue. cids, alkalis, diluted brine, sea water. Sullage, sewage effluent, town water. Effluent and processes with oil contaminants, purified water. Page of 6 MTI / MTRI Manual R

13 8 MTI Installation Sheet No. MTI USE IN FILL (HRGE) PPLITION MTI USE IN N EMPTY (ISHRGE) PPLITION Figure - MTI used in a Fill (harge) and Empty (ischarge) (ischarge) pplications MTI / MTRI Manual R Page of 6

14 MTRI Installation Sheet No. MTRI USE IN FILL (HRGE) PPLITION MTRI USE IN ISHRGE PPLITION Figure 0 MTRI pplications Page of 6 MTI / MTRI Manual R

15 0 MTRI Installation Sheet No. 0V MP MX. NORMLLY OPEN OR NORMLLY LOSE PROGRMMLE OUTPUT RELYS (IP SWITH SELETLE) TE RMIN LS NLOG INPUT 0-0V - 0M WIRE FROM MTI OR MTP MNUFTURE Y MU LTITR OE MOEL MTRI SELETE 8 VOLTGE 0 NO N RELYS N -0 M 0-0V -0 M IP SWITH SETTINGS NORMLLY OPEN NORMLLY LOSE N MX 0V E E RELY OU TPUTS MINS POWER SELET FUNTION NLOG INPUTS OU TPUTS PROE INPUTS POWER SUPPLY TERMINLS MTI 0/0 Figure - MTRI imensions Inputs: Number of outputs: ontact rating: ontact life: Supply voltage (+-0%): Power consumption: Terminal size: isplay: Enclosure type: Mounting arrangements: Operating temperature: 0 0V or 0m V nominal 0 sets of programmable N.O. or N.. contacts amp 0V resistive 0 operations 0 or 0V 0/60Hz 6 V MX. mm High intensity LE per output on front panel arranged vertically to form bar graph. Extruded aluminium Panel mounted trough cut-out brackets supplied -0 o to +60 o MTI / MTRI Manual R Page of 6

16 MultiTrode Pty Ltd UK Operations Ivybridge, evon Tel: + Fax: UKsales@multitrode.com MultiTrode Pty Ltd Head Office risbane Technology Park 8 randl Street PO ox 6 Eight Mile Plains Qld Ph: Fx: Usales@multitrode.com MultiTrode Inc US Unit, 0 South Rogers ircle oca Raton Florida 8 Tel: Fax: USsales@multitrode.net Visit for the latest information Page 6 of 6 MTI / MTRI Manual R

MultiTrode MTIC. Indicator Controller

MultiTrode MTIC. Indicator Controller MultiTrode MTI Indicator ontroller Page 2 of 18 MTI Manual R6 MTI Indicator ontroller Four ctuation elays: Method of Operation: Used to average out wave action and for other control functions. The MultiTrode

More information

INSTALLATION & OPERATION

INSTALLATION & OPERATION INSTALLATION & OPERATION MANUAL FOR MultiTrode Indicator Controller (MTIC) & MultiTrode Remote Indicator Controller (MTRIC) MTIC - Indicator Controller MTRIC - Remote Indicator Controller Version 598 MTIC

More information

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,

More information

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions. For. Level Control Module. Model SSR 1000 Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

ph Meter & Controller Model: NANO-PCD1

ph Meter & Controller Model: NANO-PCD1 Instruction Manual ph Meter & Controller Model: NANO-PCD1 Supplied by: Convergent Water Controls Pty Ltd 2/4 Huntley Street, PO Box 7058 Alexandria NSW 2015 Tel: (02) 9698 3131 www.cwc.com.au Fax: (02)

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

61F-GP-N8D. Model Number Structure. Ordering Information. Conductive Level Controller. Model Number Legend. List of Models

61F-GP-N8D. Model Number Structure. Ordering Information. Conductive Level Controller. Model Number Legend. List of Models Conductive Level Controller 61F-GP-N8 Compact Plug-in Level for Single or Two-point Level Control of Conductive Materials (Liquids and Solids) Wide range of models: long-distance, high and low-sensitivity,

More information

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2

4-Pole Relay. 2 Coil. [V] Hz A1 A2 60 Hz A24 A1 A20 A2 ulletin - Product Overview/Product Selection ulletin - Industrial Relay ontact cartridges convertible from.o. to.. and vice versa EM V coils Pneumatic timing unit Solid-state timing unit Overlap contacts

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Compact Plug-in Level s for Single or Two-point Level Control of Conductive Materials (Liquids and Solids) Wide range of models: long-distance, high and low-sensitivity, and two-wired

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723

More information

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL INTRINSICALLY SAFE DUPLEXER INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision:

More information

Capacitive Proximity Sensor E2K-C

Capacitive Proximity Sensor E2K-C 3 to 5 mm, adjustable Sensing Supply voltage Output 9 to 5AC, 5/6 Hz 1 to 4DC ma ma, NPN or PNP Capacitive Proximity Sensor Cylindrical Sensor Offers Adjustable Detecting Distance Permits non-contact detection

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703 SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION

More information

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES DS 13.321 BAS 2800+ 06/99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER Specification no. 579-1-904 The Universal Network Controller (UNC 596) is fully intelligent and incorporates its

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website: SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 12 Revision Date: 8-27-14

More information

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4

More information

Installation Manual for D244X Series 24-volt Power Supplies

Installation Manual for D244X Series 24-volt Power Supplies Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power

More information

Instruction Manual. ICENI/MA-01 MODBUS Master Module. Pub_ Issue 1

Instruction Manual. ICENI/MA-01 MODBUS Master Module. Pub_ Issue 1 Instruction Manual ICENI/MA-01 MODBUS Master Module Pub_363 - Issue 1 Regulateurs Europa Ltd 2014 The contents of this document are the exclusive Property of Regulateurs Europa Ltd They must not be copied

More information

LIQUID LEVEL CONTROLS. Conductance Actuated Probe Type. Series LPC General Purpose Liquid Level Controls. Electrical Ratings

LIQUID LEVEL CONTROLS. Conductance Actuated Probe Type. Series LPC General Purpose Liquid Level Controls. Electrical Ratings onductance ctuated Probe Type Series LP-2000 Industrial and commercial level sensing and pump control of cooling towers, tanks, water fountains, condensate units, and others. igital technology utilizing

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Strip Chart Recorders Specification Sheet

Strip Chart Recorders Specification Sheet 4101C, 4101M 4102C, 4102M MODELS Continuous Pen Recording 1, 2, 3 or 4 Pens Multi-point Recording Providing 6 Colour traces High Visibility Display 4101C, 4101M Clear Analogue Scale 4102C, 4102M Large

More information

H3CA-8H-AC/100/110/120

H3CA-8H-AC/100/110/120 Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

4 Wiring Brochure Wiring and

4 Wiring Brochure Wiring and - Wiring Brochure ing Expansion Module 444 W 444 12/08 1 Information Brochure hoose controls to match application Application Brochure Design your mechanical applications 2 3 ough-in Wiring ough-in 4 Wiring

More information

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide

BlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide BlueWave ~ Intelligent Energy Control Installation and User Manual for BW2/C and BW3/C versions Quick Guide Press button to override or activate Channel 1 Press button to override or activate Channel 2

More information

MEASURING AND MONITORING RELAYS

MEASURING AND MONITORING RELAYS MEASURING AND MITORING RELAYS Slim Models for Monitoring Current and Voltage NEW Measuring and Monitoring Relays Measuring and Monitoring Relays K8AB Industry First! Measuring and Monitoring Relays Two

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to -point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

E2K-C25MY1 E2K-C25MY2

E2K-C25MY1 E2K-C25MY2 Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-6 3 Ph: 4353 8888 Mob: 99 4353 8888 Fax: 44 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Sensing Supply voltage

More information

Measuring and Monitoring Relays

Measuring and Monitoring Relays Measuring and Monitoring Relays K8AB Series/61F-D21T Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.5 mm Seven slim models featuring a variety of innovative new functions. Single-phase

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

PROXIMITY SENSORS SEZ/SEM SERIES

PROXIMITY SENSORS SEZ/SEM SERIES PROXIMITY SNSORS SZ/SM SRIS Description SM/SZ series touchless sensors are designed to detect objects through most materials. They operate from low voltage power source and provide simple digital or analog

More information

100/140 Franker Link Unit Operator Manual

100/140 Franker Link Unit Operator Manual Table of Contents SECTION 1 Page 1 Machine specification sheet...3 2 Description of unit...4 3 Machine features...5 4 Machine layout...6 5 Turn plate adjustment...7 Page 1 IMPORTANT NOTICE Before connecting

More information

From: Dan Toon, EXECUTIVE MANAGER COMMERCIAL SERVICES. Date: 15 August 2007 (Supersedes the 06 March 2007 issue)

From: Dan Toon, EXECUTIVE MANAGER COMMERCIAL SERVICES. Date: 15 August 2007 (Supersedes the 06 March 2007 issue) Memorandum To: Donna Ward, DEPOT FINANCIAL SERVICES SUPERVISOR From: Dan Toon, EXECUTIVE MANAGER COMMERCIAL SERVICES cc: Date: 15 August 2007 (Supersedes the 06 March 2007 issue) Re: Purchase Specification

More information

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar Plug-in module SIRAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SIRAX TV 808 (Fig. ) is to electrically insulate

More information

LC2300 Level Controller Installation and Maintenance Instructions

LC2300 Level Controller Installation and Maintenance Instructions 4025350/5 IM-P402-72 AB Issue 5 LC2300 Level Controller Installation and Maintenance Instructions 1 General safety information LC2300 2 General product information 3 Installation >50% >100%

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

MEASURING AND MONITORING RELAYS

MEASURING AND MONITORING RELAYS MEASURING AND MITORING RELAYS Slim Models for Monitoring Current and Voltage NEW Measuring and Monitoring Relays Measuring and Monitoring Relays K8AB Industry First! Measuring and Monitoring Relays Two

More information

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured

F3SJ-A F3SJ-A. Safety Light Curtain. safety light curtain that. Options. software. The F3SJ-A system is a fullfeatured C R US Options n Handheld setting console n S manager programming software n F3SP/F3SX Safety Controller n Weld shields n IP67 enclosures n Multiple mounting options n escription F3SJ- Safety Light Curtain

More information

E2Q4 Square Proximity Sensor

E2Q4 Square Proximity Sensor Inductive Square Slim, compact size M2 Plug-in connection Integrated short circuit and reverse polarity protection Active face positioning: Y-axis 5, X-axis 90 incremets Ordering Information DC type Connection

More information

D/E Remote Relay Panel User Guide

D/E Remote Relay Panel User Guide D/E Remote Relay Panel User Guide This manual should remain with the unit. D/E Remote Relay Panel Detailed Specifications...2 Environmental Specs...2 Power Supply Requirements...2 Relay Outputs (8)...2

More information

Basic User and Installation Manual

Basic User and Installation Manual HERON ELECTRIC COMPANY LTD Basic User and Installation Manual Mi-4 Mi-8 Mi-12 Mi-16 Mi-144 Multi -Wire Controller Doc ref. Mi Multi Wire Basic November 2008 TABLE OF CONTENTS 1. About This Controller...

More information

Electrical Specifications

Electrical Specifications Electrical Specifications Input Voltage Input Power Input Frequency 87-240V AC 65W Maximum (20W Typical) 47-63 Hz Material Specifications Main unit: Anodised Aluminium End plates: UL V-0 rated polycarbonate

More information

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE INSTALLATION MANUAL VX-2000 series PILOT TONE DETETION MODULE IMPEDANE DETETION MODULE VX-200SP-2 VX-200SZ-2 Thank you for purchasing TOA s VX-2000 series plug-in modules. Please carefully follow the instructions

More information

HAT162 ATS CONTROLLER USER MANUAL

HAT162 ATS CONTROLLER USER MANUAL HAT162 ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd. No. 28 Jinsuo Road Zhengzhou

More information

Operating & Maintenance Instructions Dry Running Protection Device DRP-001

Operating & Maintenance Instructions Dry Running Protection Device DRP-001 Operating & Maintenance Instructions Dry Running Protection Device DRP-001 AD MANUAL NO: AD-50-001-00 Roto Pumps Ltd. Roto House, Noida Special Economic Zone Phase II, Noida 201305, Uttar Pradesh (India)

More information

icon Series Controls

icon Series Controls icon Series Controls icon Series Controls Introducing the Bianco icon range of intelligent controllers. The icon range of intelligent controllers are suitable for installation in various Industrial and

More information

PSSU/A Control Unit Installation Instructions

PSSU/A Control Unit Installation Instructions elease0 /0 Ver.. Installation Instructions: PSSU/ ontrol Unit PSSU/ ontrol Unit Installation Instructions INTOUTION The PSSU/ control unit is designed to be used with Tapeswitch pressure sensitive sensors,

More information

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK The Studio 1800 is a combined Programmer and Temperature Controller which has been specifically designed for use with pottery kilns. Control of

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

Contents Contents 2 Preface 3 Introduction 4 Components 5 Operation 6 Timer 7 Lamp Replacement 9 Specification 10 Ordering Information 11 2

Contents Contents 2 Preface 3 Introduction 4 Components 5 Operation 6 Timer 7 Lamp Replacement 9 Specification 10 Ordering Information 11 2 SPOT-LITE CURING SYSTEM USER S GUIDE http://www uvp com UVP, Inc Ultra-Violet Products Ltd 2066 W 11 th Street Unit 1, Trinity Hall Estate, Nuffield Road Upland, CA 91768 USA Cambridge, CB4 1TG, UK (800)

More information

Chennai Weighing System

Chennai Weighing System Chennai Weighing System No:27/1, New Boag Road, T.Nagar,Chennai- 600017 Cell:98400 29989, Ph:044-2432 0078 E-mail:chennai_weighing@yahoo.co.in Contact Person: D.Dayabaran CWS CONTENTS : Product Information

More information

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool echnical data sheet LHA-MF..-P Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

SPECIFICATIONS NB SKILLS PROVINCIAL COMPETITION AUTOMATION AND CONTROL APRIL 20, 2018-NBCC MONCTON LE 20 AVRIL-NBCC MONCTON

SPECIFICATIONS NB SKILLS PROVINCIAL COMPETITION AUTOMATION AND CONTROL APRIL 20, 2018-NBCC MONCTON LE 20 AVRIL-NBCC MONCTON NB Provincial Skills Competition Industrial Control (formerly called Automation & Control) SPECIFICATIONS NB SKILLS PROVINCIAL COMPETITION AUTOMATION AND CONTROL APRIL 20, 2018-NBCC MONCTON LE 20 AVRIL-NBCC

More information

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011

PLC Fundamentals. Module 2: Hardware and Terminology. Academic Services Unit PREPARED BY. August 2011 PLC Fundamentals Module 2: Hardware and Terminology PREPARED BY Academic Services Unit August 2011 Applied Technology High Schools, 2011 ATE1212 PLC Fundamentals Module 2: Hardware and Terminology Module

More information

MEASURING AND MONITORING RELAYS

MEASURING AND MONITORING RELAYS MEASURING AND MITORING RELAYS Slim Models for Monitoring Current and Voltage NEW Measuring and Monitoring Relays Measuring and Monitoring Relays K8AB Industry First! Measuring and Monitoring Relays Two

More information

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document. Rotary Encoder Solutions Limited Dutton Road Redwither Business

More information

Peak/Valley Hold Unit (PVHU) User Manual V3.00

Peak/Valley Hold Unit (PVHU) User Manual V3.00 Peak/Valley Hold Unit (PVHU) User Manual V3.00 Part Number: DO-UM0084/30/UE Applies to Firmware Version: V3.01 Reference: Peak_Valley Hold Unit (PVHU) User Manual.docx Date: 30 May 2016 Version: 3.00 Peak/Valley

More information

Heating Circuit Controller

Heating Circuit Controller 2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB

More information

Analog display for resistance current

Analog display for resistance current www.reinhausen.com Analog display for resistance current Operating Instructions BA 2220061/01 NOTE The product may have been modified after this document went to press. We expressly reserve the right to

More information

/8 DIN Universal Process Indicator

/8 DIN Universal Process Indicator Data Sheet SS/_ High visibility LED display the clearest view of your process status.% measurement accuracy precise indication of process measurement Analog and relay outputs as standard alarm and retransmission

More information

Product Data Sheet. BMS/Graphics Interface. Features

Product Data Sheet. BMS/Graphics Interface. Features BMS/Graphics Interface Product Data Sheet Features The Mxp-010 interface allows BMS systems and graphics PCs to be integrated with the Mx- 4000 series of Fire Control Panels and Remote Terminals. The interface

More information

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website: SC100 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 1 Revision Date: 4-2-18

More information

DOR6. Components All functions and indications are on the front of the module. Characteristics

DOR6. Components All functions and indications are on the front of the module. Characteristics Priva Blue ID C-Line Relay output module Easy installation You simply click the module onto the DIN rail. The wiring connects to the module via spring terminals or screw connectors (optional). The module

More information

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC

More information

PSSU/A2 Control Unit Installation Instructions

PSSU/A2 Control Unit Installation Instructions PSSU/ Unit Installation Instructions INTROUTION The PSSU/ control unit is designed to be used with Tapeswitch pressure sensitive sensors, such as ribbon switches, sensing edges, bumpers, and presence-sensing

More information

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number 30GXN,R Sizes 080-528 Air-Cooled Chillers with ComfortLink Controls 50/60 Hz Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS Unit 30GXN,R Voltage Figure Number Label Diagram No. 30GX 080-178* ALL 1 505429

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O Product Data Sheet CODEL Continuous Emission Monitoring GCEM4000 Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O In-situ, low maintenance devices for continuous process and emissions

More information

Installation and Operation Guide

Installation and Operation Guide Installation and Operation Guide Network -Isolator Contents Introduction...3 Installation...3 Mounting...3 Wiring and Terminal locks...4 Network Connections...4 Configuration/...7 Power Connection...7

More information

Super universal modules

Super universal modules s 8 174 TX-I/O Super universal modules TXM1.8X TXM1.8X-ML Two fully compatible versions: TXM1.8X: 8 inputs/outputs with LED signal / fault indication TXM1.8X-ML: As TXM1.8X, but with additional local override

More information

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ TR RS -0 0 /5 en - 06 00 RU/, RU/ (RUT /) ontrol and interlock devices rogrammable compact devices for local control, interlock and energy management functions in V systems They may be used for stand-alone

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual.  Page 1 of 13 Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:

More information

Digital Thermostat for drum heaters Model HCL 5536

Digital Thermostat for drum heaters Model HCL 5536 Digital Thermostat for drum heaters Model HCL 5536 Dear Customer, we would like to use this opportunity to thank you for buying this product from Friedr. Freek GmbH. Please read this document carefully

More information

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11

More information

Installing Keypad and Backplate

Installing Keypad and Backplate Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Analog micro push button

Analog micro push button Analog micro push button for rugged applications 145MA... + 0.5...4.5 V DC analog output at 5 ± 0.5 V DC operating voltage + output signal can be adjusted within the voltage range + non-contact operation

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Testomat AW101 Water hardness monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET. Testomat AW101 Water hardness monitor ABB MEASUREMENT & ANALYTICS DATA SHEET Testomat AW101 Water hardness monitor TE STO MAT AW 101 WATER H ARDNE SS MONITOR DS/AW100-E N RE V. E Measurement made easy A unique water hardness monitoring system

More information

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual Document number 057-135 Author : Paul Gibbons DSE103 MKII Operator Manual Issue 1 Deep Sea Electronics Plc Highfield House Hunmanby North

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

SMS 4 / SMS 5 safety mat Product information

SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mat Product information SMS 4 / SMS 5 safety mats Safety mats are used for the protection of man on machinery and plants with hazardous movements. Typical fields of application are,

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Installation and Setting up Instructions for the Type 920 Auto Sequencer

Installation and Setting up Instructions for the Type 920 Auto Sequencer Installation and Setting up Instructions for the Type 920 Auto Sequencer Hawker Electronics Limited O&M 86 57 The Avenue, Issue C Rubery Industrial Estate, April 2016 Birmingham, B45 9AL Tel: +44(0)121-453-8911

More information

Metham Aviation Design Limited Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0)

Metham Aviation Design Limited Station Approach, Four Marks, Alton. Hants. GU34 5HN Tel +44 (0) Fax +44 (0) Contents Page General Information 1 Items Supplied 1 Variants 1 Compatibility with other products 2 Mounting the Housing assembly 2 Mounting the Camera/Lens assembly 3 Safety Precautions 4 Control Connections

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX

Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Position Transducers Pivot head mounting potentiometric up to 300 mm, IP54 Series TEX Special features compact dimensions protection class IP54 mountable over back-lash free pivot heads with a large angle

More information

AX200. Installation Guide

AX200. Installation Guide Axxess Identification Ltd 27-28 Shrivenham Hundred Business Park, Watchfield, Swindon, Wiltshire SN6 8TZ United Kingdom Tel: +44 (0)1793 784002 Fax: +44 (0)1793 784005 Email: info@axxessid.com May 2008

More information

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020

genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020 Australian Owned, Designed and Manufactured I/O Expander GEN-020 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

Electronic time relays ATI, BTI, SDT and MTI

Electronic time relays ATI, BTI, SDT and MTI MAKING MODERN LIVING POSSIBLE Technical brochure Electronic time relays ATI, BTI, SDT and MTI With their robust design and many built-in functions, electronic timers ATI, BTI, SDT and MTI are ideal for

More information

LS 5000 series Vibration Level Switch for liquids

LS 5000 series Vibration Level Switch for liquids Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,

More information

Test devices and Multifunction timer relay

Test devices and Multifunction timer relay Test devices and Multifunction timer relay VARIOTEST ROTATEST CSG420 Test devices Industries VARIOTEST The Condor-VARIOTEST is a universal test instrument featuring acoustic signals for: P. 145 Testing

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

P1/PD IDEC Pump User Guide

P1/PD IDEC Pump User Guide P1/P I Pump User Guide Pump Setup and Powering I lectronics 1. Plug in the ON 1 30 pin circular mating connector, that was supplied by Parker, into the pump, see igure 1. 2. Power the pump electronics

More information

Product Data Sheet. Hochiki 8 Way I/O Card. Features

Product Data Sheet. Hochiki 8 Way I/O Card. Features Hochiki 8 Way I/O Card Product Data Sheet Features The Mxp-019 is a stand-alone fire system peripheral based on the Hochiki ESP protocol for use with the Mx-4000 range of panels. The unit connects to the

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information