genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020

Size: px
Start display at page:

Download "genesis genesis I/O Expander - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured I/O Expander GEN-020"

Transcription

1 Australian Owned, Designed and Manufactured I/O Expander GEN-020 Genesis Electronics Australia Pty Ltd Distributed by: Genesis reserves the right to change or modify products without notice. This manual assumes installers of this product are professionals within the electronic security, access control and automation industry. As such, knowledge of these industries on the part of the installer is assumed. Genesis takes no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the correct or incorrect use of any Genesis devices. genesis The very latest innovation in security and access TEHNIAL MANUAL Revision 2.01 September 2002 Genesis Electronics Australia Pty Ltd Page 12 Revision 2.01 September 2002

2 Table of ontents Sample EOL Resistor Values: TABLE OF ONTENTS 2 3K3/3K3 N/ 3K3 = Sealed 6K6 = Unsealed Tamper High 135 Tamper Low 72 Unsealed High 85 Unsealed Low 72 PARTS HEKLIST 3 3K3/3K3-3K3 =Sealed 1K7 = Unsealed Tamper High 135 SPEIFIATIONS 3 FEATURES AND BENEFITS 4 10K Single EOL INPUT LAYOUT AND WIRING 5 I/O EXPANDER PB LAYOUT 7 MOUNTING 8 POINTS TO NOTE 9 SAMPLE EOL RESISTOR VALUES 10 Tamper Low 72 Unsealed High 135 Unsealed Low 110 6K8 Single EOL Unsealed High 135 Unsealed Low 110 4K7 Single EOL Unsealed High 110 Unsealed Low 85 3K3 Single EOL Unsealed High 95 Unsealed Low 60 2K2 Single EOL Unsealed High 70 Unsealed Low 50 1K Single EOL Unsealed High 35 Unsealed Low 25 Page 2 Revision 2.01 September 2002 Version 2.01 September 2002 Page 11

3 Sample EOL Resistor Values: 10K/4K7 N/ 10K=Sealed, 14K7=Unsealed Tamper High 180 Tamper Low K/4K7 14K7 = Sealed 10K = Unsealed Tamper High 180 Tamper Low 140 Unsealed High 180 Unsealed Low 165 Short ircuit Short = Sealed Open = Unsealed Unsealed High 20 Unsealed Low 0 Open ircuit Open = Sealed Short = Unsealed Unsealed High 255 Unsealed Low 25 10K/10K N/ 10K = Sealed 20K = Unsealed Tamper High 200 Tamper Low K/10K 10K = Sealed 5K = Unsealed Tamper High 165 Tamper Low 85 2K2/6K8 N/ 2K2= Sealed 9K = Unsealed Tamper High 160 Tamper Low 50 Unsealed High 76 Unsealed Low 50 2K2/6K8 9K = Sealed 2K2 = Unsealed Tamper High 160 Tamper Low 50 Unsealed High 160 Unsealed Low 135 Page 10 Revision 2.01 September 2002 Parts hecklist: 1 x I/O Expander (GEN-020) 1 x 16 pin ribbon cable 16 x 10K Resistors (1% Tolerance) 16 x 4.7K Resistors (5% Tolerance) 16 x 2 pin Terminal Blocks 4 x 3 pin Terminal Blocks 4 x mounting screws 1 x I/O Expander Technical Manual (this manual) Specifications: Dimensions (H x W x D): Processor: Memory: Input Voltage: Standby urrent Draw: Inputs Outputs 145 x 80 x 20 mm Version 2.01 September 2002 Page 3 nil nil Supplied by Master Unit or Expander Unit 10mA + 60mA per active output 16 x four state, tamper monitored inputs 4 x change over contacts ( & N/) Relays are voltage free contacts. Maximum resistive current = 30VD or 250VA Maximum inductive urrent = 30VD or 250VA aution: All Genesis devices are electrostatic sensitive devices. As such, all care should be taken to ensure appropriate procedures are in place when handling and installing Genesis devices. This may include, but is not limited to wearing an appropriately earthed, conductive wrist strap to limit electrostatic discharge into Genesis devices.

4 Features and Benefits: The Genesis I/O Expander connects directly to the Genesis Master Unit or Genesis Expander Unit with a 16 pin ribbon cable, quickly and easily expanding the number of inputs and outputs provided on each device. Points to Note: Removal of the Serial Number from any Genesis device will immediately void any warranty applicable to it, or any interconnected Genesis device. The I/O Expander provides an additional 16 four state monitored inputs, as well as 4 change over relay contacts. Designed as an integral part of any Genesis system, the I/O Expander board fits into the standard Genesis metal equipment cabinet, right next to the Master or Expander Unit. WARNING: THIS DEVIE IS NOT DESIGNED OR APPROVED FOR DIRETLY SWITHING MAINS SUPPLY VOLTAGE. IF SWITHING OF MAINS SUPPLY VOLTAGE IS REQUIRED, A SEPARATE BUFFER RELAY OR ONTATOR MUST BE INSTALLED TO LOAL OR STATE STANDARDS. Page 4 Revision 2.01 September 2002 Version 2.01 September 2002 Page 9

5 Mounting: The I/O Expander is designed to mount alongside the GEN-001 Master Unit, or GEN-010 Expander Unit, that it is being connected to. - Avoid installing the I/O Expander outdoors. - Avoid installing the I/O Expander where it may be exposed to moisture, either directly (Rain, Sprinklers, Hoses), or by condensation. Input Layout and Wiring: 16 Input Terminals, with individual common returns are supplied on the Genesis I/O Expander. The Genesis Genesis I/O Expander allows for each input to have a different End of Line resistor value. (up to 16 EOL values). This includes tamper monitoring, through Dual End of Line resistors. The Genesis panel is supplied with the following resistor combination as standard: = Sealed 14.7KΩ = Alarm ( + 4.7KΩ) However, these values can be changed from within the Genesis Technician Software, to suit most resistor configurations. Example 1 PIR Dual EOL, Normally losed 4.7KΩ ALA RM TAM PER Example 2 Switch Dual EOL, Normally losed 1 4.7KΩ 2 Page 8 Revision 2.01 September 2002 Version 2.01 September 2002 Page 5

6 Input Wiring: Example 3 PIR Single EOL, Example 4 Smoke Detector Normally losed Single EOL, Normally Open ALA RM TAM PER ALA RM TAM PER 3 4 Example 5 Switch Single EOL, Example 6 Switch Single EOL, Normally losed Normally Open I/O Expander PB Layout: Output 5 N/ Output 8 N/ Output 6 N/ Output 7 N/ 5 Example 7 Smoke Detector Dual EOL, Normally Open 4.7KΩ ALA RM TAM PER 7 Example 8 Switch Dual EOL, Normally Open 4.7KΩ Master Unit Layout: 8 6 Note: These examples are for the purpose of illustrating the most commonly used input wiring configurations. Different detection devices may require wiring in a different fashion to these examples. Inputs 17 to 24 Input 25 to 32 I/O EXPANDER BUS This 16 pin socket is provided for connection between the GEN-001 Master Unit and the GEN-020 I/O Expander, or the GEN-010 Expander Unit and the GEN-020 I/O Expander. SERIAL NUMBER Each Genesis device is fitted with it s own unique Serial Number. Removal of the Serial Number will void Warranty Page 6 Revision 2.01 September 2002 Version 2.01 September 2002 Page 7

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010 Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured

genesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products

More information

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010

genesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010 16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Two Door Controller GEN-045

Two Door Controller GEN-045 Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify

More information

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

genesis TECHNICAL MANUAL Two-Door Controller GEN-045 Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves

More information

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,

More information

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel. Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit

More information

16-Way Input 48-Way Output Card

16-Way Input 48-Way Output Card 16-Way Input 48-Way Output Card Features 16 Configurable Inputs Push Button, Switch Input Fast Input Response 48 Configurable Outputs OFF, ON, 0.5S ON / 0.5S OFF, 1S ON / 1S OFF Configurable Buzzer OFF,

More information

Vocia. Page Active Relay Module (PARM-1) Operation Manual

Vocia. Page Active Relay Module (PARM-1) Operation Manual Vocia Page Active Relay Module (PARM-1) Operation Manual Biamp System 9300 SW Gemini Drive, Beaverton, OR 97008 U.S.A. (503) 641-7287 www.biamp.com table of contents Vocia Page Active Relay Module (PARM-1)

More information

Cardax FT Controller 3000

Cardax FT Controller 3000 Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the module indicators

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

P-Series Bear Bones I/O Expander USER S MANUAL. For P-Series Based Bear Bones Controllers ICM-IO-C21 ICM-IO-C24. Revision: 1.

P-Series Bear Bones I/O Expander USER S MANUAL. For P-Series Based Bear Bones Controllers ICM-IO-C21 ICM-IO-C24. Revision: 1. USER S MANUAL Revision: 1 For P-Series Based Bear Bones ontrollers P-Series Bear Bones I/O Expander overed Models: IM-IO-21 IM-IO-24 Divelbiss orporation 9778 Mt. Gilead Road, Fredericktown, Ohio 43019

More information

emerge Essential Access Control System

emerge Essential Access Control System emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire

More information

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7 Artistic Licence Rail-Demux User Guide Version 2-7 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

2-Way Wireless I/O Expander Installation Guide

2-Way Wireless I/O Expander Installation Guide 2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...

More information

HI SEC Integrated Systems

HI SEC Integrated Systems Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing

More information

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5 Artistic Licence Rail-Switch II User Guide Version 5-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be

More information

DG-800 Stand-Alone Proximity Reader Instruction Manual

DG-800 Stand-Alone Proximity Reader Instruction Manual DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE INSTALLATION MANUAL VX-2000 series PILOT TONE DETETION MODULE IMPEDANE DETETION MODULE VX-200SP-2 VX-200SZ-2 Thank you for purchasing TOA s VX-2000 series plug-in modules. Please carefully follow the instructions

More information

DVAA Series Disk Array for DVR1 Series Digital Video Recorder

DVAA Series Disk Array for DVR1 Series Digital Video Recorder DVAA Series Disk Array for DVR1 Series Digital Video Recorder Eng Installation Instructions Philips Communication, Security & Imaging Warning! To prevent fire and electronic shock, do not expose this product

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

CONCEPT 3000/Access 4000 User Manual UK Supplement

CONCEPT 3000/Access 4000 User Manual UK Supplement CONCEPT 3OOO & Access 4000. 1 CONCEPT 3000/Access 4000 User Manual UK Supplement Revision 5.70 This manual is intended for use in conjunction with the Concept 4000 User Manual, Revision 5.6 or later. CONTENTS

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE

GUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE GUARD CENTURION THE AUTOMATIC CHOICE OPERATING INSTRUCTIONS 0 In a In hurry? a hurry? The following KwikLearn procedure and connection diagram will enable you to start using your SmartGUARD system right

More information

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index

More information

Gallagher GBUS Devices

Gallagher GBUS Devices Gallagher GBUS Devices Gallagher GBUS I/O Devices provide flexible, cost effective input and output expansion options with an option to connect readers. Gallagher GBUS I/O Devices include the: Gallagher

More information

HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH

HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH HIGH APAITY, LONG LIFE SUBMINIATURE SWITH AVM3 P (PS) SWITHES FEATURES 10.1 Amp. high contact capacity is available Long life Precise operating (5: Pin plunger type) Flux-resistant construction with integrally

More information

T775S Series 2000 Expansion Module

T775S Series 2000 Expansion Module T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone

More information

Cardax Prox Plus Mifare Reader

Cardax Prox Plus Mifare Reader Installation Note Cardax Prox Plus Mifare Reader CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

Operating Instructions

Operating Instructions Represented in Australia by: EMONA Instruments Pty Ltd 78 Parramatta Rd Camperdown NSW 2050 Tel: (02) 9519 3933 www.emona.com.au, www.protag.com.au testinst@emona.com.au Part Number 372A580 Revision 4

More information

Protected VARAN Digital Mixed Module PVDM 086

Protected VARAN Digital Mixed Module PVDM 086 PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that

More information

9500 and 9600 I/O Card Installation Instructions

9500 and 9600 I/O Card Installation Instructions 9500 and 9600 I/O Card Installation Instructions This document describes how to install, configure, and verify the operation of the optional Input/Output card ( I/O card ) into your 9500 or 9600 power

More information

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions 3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These

More information

C-Bus Four Channel Voltage Free Relay Installation Instructions

C-Bus Four Channel Voltage Free Relay Installation Instructions C-Bus Four Channel Voltage Free Relay Installation Instructions 5504RVF Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3

More information

1395 Node Adapter Board Troubleshooting

1395 Node Adapter Board Troubleshooting 1395 Node Adapter Board Troubleshooting Specifications Electrical: Board power provided by Drive (+5V) Discrete Input 24V DC or 115V AC, jumper selectable Environmental: Ambient Operating Temperature Storage

More information

Operating instructions IO-Link master CabinetLine AL19xx

Operating instructions IO-Link master CabinetLine AL19xx Operating instructions IO-Link master CabinetLine AL19xx 80273036/00 02/2018 1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 2 Safety instructions Read

More information

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

4100/4120-Series Class A / Class B Zone Modules Installation Instructions 4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box

More information

270 MHz Control Modules

270 MHz Control Modules 2400 / 2420 / 2450 Performance Drives A D D E N D U M 270 MHz Control Modules Notices 2000.40(A2) 01 11/08 Copyright 2002-2008 by Unico, Incorporated. All rights reserved. No part of this publication may

More information

Chameleon Stand-alone

Chameleon Stand-alone Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools

More information

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation

2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation 2T15 Multi Range Digital Setting Time Delay Relay Technical Bulletin Features Four time ranges -.99s, -9.9s, -99s, -99s High accuracy & repeatability timing compensated for output relay delay Time settings

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

istar Pro Installation Guide

istar Pro Installation Guide istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general

More information

MRS ELECTRONIC DATASHEET CAN 4 ANA DESCRIPTION TECHNICAL SPECIFICATION REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING

MRS ELECTRONIC DATASHEET CAN 4 ANA DESCRIPTION TECHNICAL SPECIFICATION REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING DESRIPTION The Micro PL AN 4 ANA offers many possible applications with its 5 inputs and outputs. One analog input and four I/Os, the function of which can be individually defined. These inputs/outputs

More information

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip

Product Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-7DU2i 2 USBG-7DU2i Product Manual Revision History Revision

More information

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES

DS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES DS 13.321 BAS 2800+ 06/99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER Specification no. 579-1-904 The Universal Network Controller (UNC 596) is fully intelligent and incorporates its

More information

Control Panels B5512/B4512. en UL Installation Instructions

Control Panels B5512/B4512. en UL Installation Instructions Control Panels B551/B451 en UL Installation Instructions Control Panels Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Related documentation 4 1. Bosch Security

More information

Quick Start Installation Guide

Quick Start Installation Guide RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection

More information

Universal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL

Universal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL Revision 2.14 October. 2009 1 Overview Universal Module in Low Profile Enclosure. P/N: 995004 INSTALLATI MANUAL The Universal Module connects to a Model 3000/Access 4000 system OR a Model 2000 system,

More information

USB-PDISO8/40. USB-based Isolated Input and Relay Output. User's Guide. September Rev 6 Measurement Computing Corporation

USB-PDISO8/40. USB-based Isolated Input and Relay Output. User's Guide. September Rev 6 Measurement Computing Corporation USB-PDISO8/40 USB-based Isolated Input and Relay Output User's Guide September 2017. Rev 6 Measurement Computing Corporation Trademark and Copyright Information Measurement Computing Corporation, InstaCal,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1 15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...

More information

MANUAL. Handgelenksband WST 100. Handgelenksband- und Schuhtester. performance test for Electrostatic Wrist Straps and Conductive Shoes

MANUAL. Handgelenksband WST 100. Handgelenksband- und Schuhtester. performance test for Electrostatic Wrist Straps and Conductive Shoes MANUAL Handgelenksband- und Schuhtester Handgelenksband WST 100 performance test for Electrostatic Wrist Straps and Conductive Shoes S 2 Handbuch WST 100 Contents Description... 2 Specification... 2 Function...

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

VT805 / Monitoring system

VT805 / Monitoring system Environmental Infrastructure monitoring VT805 / Monitoring system Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible

More information

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294

More information

MR50 READER INTERFACE

MR50 READER INTERFACE 2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

2C138. Sensitive Earth Fault Relay. Features. Application. Operation

2C138. Sensitive Earth Fault Relay. Features. Application. Operation Technical Bulletin 2C138 Sensitive Earth Fault Relay Features High sensitivity (0.1% of I n ) 2 nd & 3rd harmonic & HF noise suppression - tuned to 50 Hz Optional reset functions Instantaneous (Fast),

More information

HIMatrix Safety-Related Controller Maintenance Manual

HIMatrix Safety-Related Controller Maintenance Manual HIMatrix Safety-Related Controller Maintenance Manual HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation Rev. 1.00 HI 800 455 E All HIMA products mentioned in this manual are protected by the HIMA

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

INPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup) INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)

More information

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0 Artistic Licence User Guide Serial nos. 4900 and upwards Version 5-0 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

INSTALLATION INSTRUCTIONS 923P EntryCheck TM

INSTALLATION INSTRUCTIONS 923P EntryCheck TM 801 Avenida Acaso, amarillo, a. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS 923P Entryheck TM The Entryheck 923P Indoor/Outdoor Keypad is a surface

More information

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4 Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...

More information

16-Channel Digital Input Termination Card 24Vdc

16-Channel Digital Input Termination Card 24Vdc TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital

More information

CardaxFT Reader I/O Interface

CardaxFT Reader I/O Interface CardaxFT Reader I/O Interface CardaxFT Reader I/O Interface provides I/O functionality and an interface for connecting Cardax readers to the CardaxFT system. CardaxFT Reader I/O Interface provides an interface

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder

More information

HXV SERIES HIGH VOLTAGE SWITCHING SYSTEMS

HXV SERIES HIGH VOLTAGE SWITCHING SYSTEMS BULLETIN HXV (v) HXV SERIES HIGH VOLTAGE SWITHING SYSTEMS The HXV Series are computer controlled switching systems designed for High Voltage applications. Standard systems handle signals up to volts, while

More information

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short

More information

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998 SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)

SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) TECHNICAL SPECIAL PROVISION FOR SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) FINANCIAL PROJECT NO.: 428213-2-52-02 MARION COUNTY The official record of this Technical Special Provision is the

More information

Operating Instructions

Operating Instructions Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward

More information

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0 Artistic Licence Rail-Split extreme User Guide Serial numbers 151 upwards Version 5-0 Please read these instructions before using the product. This product has been designed & manufactured for professional

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL

Digital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL COMPONENT CODES: HMI700-1-0-NN-XX HMI701-1-0-NN-XX Digital I/O Module Impro (DIO) Digital I/O Module Specifications INSTALLATION MANUAL The DIO is a Cluster Expansion Module that works in conjunction with

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112 SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL Models: SLC2102-SLC2112 SLC2102X-SLC2112X SLC2152-SLC2162 SLC2170-xx Relay

More information

BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:

BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number: BeagleBone Black USB Expansion RS232 Module Cape Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-2COM-BB 2 USB-2COM-BB Product Manual Revision History Revision Date Author Comments

More information

Operating Instructions

Operating Instructions PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number

More information

4100/4120-Series and 4010ES Relay Modules Installation Instructions

4100/4120-Series and 4010ES Relay Modules Installation Instructions 4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description

More information

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:

More information

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety

More information

AUTROFIELDBUS PROTOCOL CONVERTER BSD-321/1

AUTROFIELDBUS PROTOCOL CONVERTER BSD-321/1 UTROFIELDUS PROTOCOL CONVERTER SD-321/1 utrosafe Interactive Fire Detection System Product Datasheet Features Interfaces various types of flame and gas detectors with the utrosafe Integrated Fire and Gas

More information

REX F-0-9 Standalone or Access Controller

REX F-0-9 Standalone or Access Controller REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes

More information

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers

More information

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory

More information