1 Australian Owned, Designed and Manufactured I/O Expander GEN-020 Genesis Electronics Australia Pty Ltd Distributed by: Genesis reserves the right to change or modify products without notice. This manual assumes installers of this product are professionals within the electronic security, access control and automation industry. As such, knowledge of these industries on the part of the installer is assumed. Genesis takes no responsibility for any damage, financial loss or injury caused to any equipment, property or persons resulting from the correct or incorrect use of any Genesis devices. genesis The very latest innovation in security and access TEHNIAL MANUAL Revision 2.01 September 2002 Genesis Electronics Australia Pty Ltd Page 12 Revision 2.01 September 2002
2 Table of ontents Sample EOL Resistor Values: TABLE OF ONTENTS 2 3K3/3K3 N/ 3K3 = Sealed 6K6 = Unsealed Tamper High 135 Tamper Low 72 Unsealed High 85 Unsealed Low 72 PARTS HEKLIST 3 3K3/3K3-3K3 =Sealed 1K7 = Unsealed Tamper High 135 SPEIFIATIONS 3 FEATURES AND BENEFITS 4 10K Single EOL INPUT LAYOUT AND WIRING 5 I/O EXPANDER PB LAYOUT 7 MOUNTING 8 POINTS TO NOTE 9 SAMPLE EOL RESISTOR VALUES 10 Tamper Low 72 Unsealed High 135 Unsealed Low 110 6K8 Single EOL Unsealed High 135 Unsealed Low 110 4K7 Single EOL Unsealed High 110 Unsealed Low 85 3K3 Single EOL Unsealed High 95 Unsealed Low 60 2K2 Single EOL Unsealed High 70 Unsealed Low 50 1K Single EOL Unsealed High 35 Unsealed Low 25 Page 2 Revision 2.01 September 2002 Version 2.01 September 2002 Page 11
3 Sample EOL Resistor Values: 10K/4K7 N/ 10K=Sealed, 14K7=Unsealed Tamper High 180 Tamper Low K/4K7 14K7 = Sealed 10K = Unsealed Tamper High 180 Tamper Low 140 Unsealed High 180 Unsealed Low 165 Short ircuit Short = Sealed Open = Unsealed Unsealed High 20 Unsealed Low 0 Open ircuit Open = Sealed Short = Unsealed Unsealed High 255 Unsealed Low 25 10K/10K N/ 10K = Sealed 20K = Unsealed Tamper High 200 Tamper Low K/10K 10K = Sealed 5K = Unsealed Tamper High 165 Tamper Low 85 2K2/6K8 N/ 2K2= Sealed 9K = Unsealed Tamper High 160 Tamper Low 50 Unsealed High 76 Unsealed Low 50 2K2/6K8 9K = Sealed 2K2 = Unsealed Tamper High 160 Tamper Low 50 Unsealed High 160 Unsealed Low 135 Page 10 Revision 2.01 September 2002 Parts hecklist: 1 x I/O Expander (GEN-020) 1 x 16 pin ribbon cable 16 x 10K Resistors (1% Tolerance) 16 x 4.7K Resistors (5% Tolerance) 16 x 2 pin Terminal Blocks 4 x 3 pin Terminal Blocks 4 x mounting screws 1 x I/O Expander Technical Manual (this manual) Specifications: Dimensions (H x W x D): Processor: Memory: Input Voltage: Standby urrent Draw: Inputs Outputs 145 x 80 x 20 mm Version 2.01 September 2002 Page 3 nil nil Supplied by Master Unit or Expander Unit 10mA + 60mA per active output 16 x four state, tamper monitored inputs 4 x change over contacts ( & N/) Relays are voltage free contacts. Maximum resistive current = 30VD or 250VA Maximum inductive urrent = 30VD or 250VA aution: All Genesis devices are electrostatic sensitive devices. As such, all care should be taken to ensure appropriate procedures are in place when handling and installing Genesis devices. This may include, but is not limited to wearing an appropriately earthed, conductive wrist strap to limit electrostatic discharge into Genesis devices.
4 Features and Benefits: The Genesis I/O Expander connects directly to the Genesis Master Unit or Genesis Expander Unit with a 16 pin ribbon cable, quickly and easily expanding the number of inputs and outputs provided on each device. Points to Note: Removal of the Serial Number from any Genesis device will immediately void any warranty applicable to it, or any interconnected Genesis device. The I/O Expander provides an additional 16 four state monitored inputs, as well as 4 change over relay contacts. Designed as an integral part of any Genesis system, the I/O Expander board fits into the standard Genesis metal equipment cabinet, right next to the Master or Expander Unit. WARNING: THIS DEVIE IS NOT DESIGNED OR APPROVED FOR DIRETLY SWITHING MAINS SUPPLY VOLTAGE. IF SWITHING OF MAINS SUPPLY VOLTAGE IS REQUIRED, A SEPARATE BUFFER RELAY OR ONTATOR MUST BE INSTALLED TO LOAL OR STATE STANDARDS. Page 4 Revision 2.01 September 2002 Version 2.01 September 2002 Page 9
5 Mounting: The I/O Expander is designed to mount alongside the GEN-001 Master Unit, or GEN-010 Expander Unit, that it is being connected to. - Avoid installing the I/O Expander outdoors. - Avoid installing the I/O Expander where it may be exposed to moisture, either directly (Rain, Sprinklers, Hoses), or by condensation. Input Layout and Wiring: 16 Input Terminals, with individual common returns are supplied on the Genesis I/O Expander. The Genesis Genesis I/O Expander allows for each input to have a different End of Line resistor value. (up to 16 EOL values). This includes tamper monitoring, through Dual End of Line resistors. The Genesis panel is supplied with the following resistor combination as standard: = Sealed 14.7KΩ = Alarm ( + 4.7KΩ) However, these values can be changed from within the Genesis Technician Software, to suit most resistor configurations. Example 1 PIR Dual EOL, Normally losed 4.7KΩ ALA RM TAM PER Example 2 Switch Dual EOL, Normally losed 1 4.7KΩ 2 Page 8 Revision 2.01 September 2002 Version 2.01 September 2002 Page 5
6 Input Wiring: Example 3 PIR Single EOL, Example 4 Smoke Detector Normally losed Single EOL, Normally Open ALA RM TAM PER ALA RM TAM PER 3 4 Example 5 Switch Single EOL, Example 6 Switch Single EOL, Normally losed Normally Open I/O Expander PB Layout: Output 5 N/ Output 8 N/ Output 6 N/ Output 7 N/ 5 Example 7 Smoke Detector Dual EOL, Normally Open 4.7KΩ ALA RM TAM PER 7 Example 8 Switch Dual EOL, Normally Open 4.7KΩ Master Unit Layout: 8 6 Note: These examples are for the purpose of illustrating the most commonly used input wiring configurations. Different detection devices may require wiring in a different fashion to these examples. Inputs 17 to 24 Input 25 to 32 I/O EXPANDER BUS This 16 pin socket is provided for connection between the GEN-001 Master Unit and the GEN-020 I/O Expander, or the GEN-010 Expander Unit and the GEN-020 I/O Expander. SERIAL NUMBER Each Genesis device is fitted with it s own unique Serial Number. Removal of the Serial Number will void Warranty Page 6 Revision 2.01 September 2002 Version 2.01 September 2002 Page 7
genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010
Australian Owned, Designed and Manufactured Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationgenesis Master Unit GEN-001 genesis Master Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured
Australian Owned, Designed and Manufactured Master Unit GEN-001 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify products
More informationgenesis TECHNICAL MANUAL 16-Input Expander Unit GEN-010
16-Input Expander Unit GEN-010 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationIntegriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL
Revision 2.1 July. 2014 1 Integriti 8 32 Zone LAN Expander Module Kit P/N: 996005PCB&K For Rev. B PCB. INSTALLATION MANUAL Overview The Integriti 8 Zone Expander Module provides an additional 8 Zone inputs,
More informationNETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.
Revised! see Protective Earthing Addendum cback NOTE: This equipment must only be installed and serviced by professional qualified personnel. The Network Concentrator Link is a fully self contained unit
More information16-Way Input 48-Way Output Card
16-Way Input 48-Way Output Card Features 16 Configurable Inputs Push Button, Switch Input Fast Input Response 48 Configurable Outputs OFF, ON, 0.5S ON / 0.5S OFF, 1S ON / 1S OFF Configurable Buzzer OFF,
More informationVocia. Page Active Relay Module (PARM-1) Operation Manual
Vocia Page Active Relay Module (PARM-1) Operation Manual Biamp System 9300 SW Gemini Drive, Beaverton, OR 97008 U.S.A. (503) 641-7287 www.biamp.com table of contents Vocia Page Active Relay Module (PARM-1)
More informationCardax FT Controller 3000
Installation Note Cardax FT Controller 000 CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning any
More informationInstallation Instructions
Installation Instructions This document provides information on: important pre-installation considerations power supply requirements initial handling procedures installing the module using the module indicators
More informationUniversal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications
12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception
More informationP-Series Bear Bones I/O Expander USER S MANUAL. For P-Series Based Bear Bones Controllers ICM-IO-C21 ICM-IO-C24. Revision: 1.
USER S MANUAL Revision: 1 For P-Series Based Bear Bones ontrollers P-Series Bear Bones I/O Expander overed Models: IM-IO-21 IM-IO-24 Divelbiss orporation 9778 Mt. Gilead Road, Fredericktown, Ohio 43019
More informationemerge Essential Access Control System
emerge Essential Access ontrol System Document Number: 620-100239, Rev. Installation Guide Linear LL 1950 amino Vida Roble, Suite 150 arlsbad, A 92008-6517 www.linearcorp.com Notices All rights strictly
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationOPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating
More informationTS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual
TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual P/N MAINST-867/869 REV 07 ISS 26NOV13 Copyright Trademarks and patents Manufacturer ACMA compliance Contact information 2013 UTC Fire
More informationArtistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7
Artistic Licence Rail-Demux User Guide Version 2-7 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be installed
More informationModel HM-535 Power Supply Installation and Service Instructions
Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS
More information2-Way Wireless I/O Expander Installation Guide
2-Way Wireless I/O Expander Installation Guide For more detailed information please refer to the iconnect Installer Manual provided on our website: www.electronics-line.com Table of Contents 1. Introduction...
More informationHI SEC Integrated Systems
Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing
More informationArtistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5
Artistic Licence Rail-Switch II User Guide Version 5-5 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It should only be
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationEOS-6000 Series Optical A/B Switch User Manual DC Version
EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2
More informationPILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE
INSTALLATION MANUAL VX-2000 series PILOT TONE DETETION MODULE IMPEDANE DETETION MODULE VX-200SP-2 VX-200SZ-2 Thank you for purchasing TOA s VX-2000 series plug-in modules. Please carefully follow the instructions
More informationDVAA Series Disk Array for DVR1 Series Digital Video Recorder
DVAA Series Disk Array for DVR1 Series Digital Video Recorder Eng Installation Instructions Philips Communication, Security & Imaging Warning! To prevent fire and electronic shock, do not expose this product
More information1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT
Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN
More informationCONCEPT 3000/Access 4000 User Manual UK Supplement
CONCEPT 3OOO & Access 4000. 1 CONCEPT 3000/Access 4000 User Manual UK Supplement Revision 5.70 This manual is intended for use in conjunction with the Concept 4000 User Manual, Revision 5.6 or later. CONTENTS
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationGUARD CENTURION OPERATING INSTRUCTIONS THE AUTOMATIC CHOICE
GUARD CENTURION THE AUTOMATIC CHOICE OPERATING INSTRUCTIONS 0 In a In hurry? a hurry? The following KwikLearn procedure and connection diagram will enable you to start using your SmartGUARD system right
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationGallagher GBUS Devices
Gallagher GBUS Devices Gallagher GBUS I/O Devices provide flexible, cost effective input and output expansion options with an option to connect readers. Gallagher GBUS I/O Devices include the: Gallagher
More informationHIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH
HIGH APAITY, LONG LIFE SUBMINIATURE SWITH AVM3 P (PS) SWITHES FEATURES 10.1 Amp. high contact capacity is available Long life Precise operating (5: Pin plunger type) Flux-resistant construction with integrally
More informationT775S Series 2000 Expansion Module
T775S Series 000 Expansion Module INSTALLATION INSTRUTIONS PRODUT DESRIPTION The T775S008 Relay Expansion Module is a four relay device for use with the T775L007 and T775P00 Series 000 Electronic Stand-Alone
More informationCardax Prox Plus Mifare Reader
Installation Note Cardax Prox Plus Mifare Reader CAUTION This equipment contains components that can be damaged by electrostatic discharge. Ensure both you and the equipment are earthed before beginning
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationOperating Instructions
Represented in Australia by: EMONA Instruments Pty Ltd 78 Parramatta Rd Camperdown NSW 2050 Tel: (02) 9519 3933 www.emona.com.au, www.protag.com.au testinst@emona.com.au Part Number 372A580 Revision 4
More informationProtected VARAN Digital Mixed Module PVDM 086
PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that
More information9500 and 9600 I/O Card Installation Instructions
9500 and 9600 I/O Card Installation Instructions This document describes how to install, configure, and verify the operation of the optional Input/Output card ( I/O card ) into your 9500 or 9600 power
More information3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions
3710 ACM 3750 PDC 3800 RTU ISOCOM Communications Card Retrofit Instructions Danger During normal operation of this device, hazardous voltages are present which can cause severe injury or death. These
More informationC-Bus Four Channel Voltage Free Relay Installation Instructions
C-Bus Four Channel Voltage Free Relay Installation Instructions 5504RVF Series REGISTERED DESIGN REGISTERED PATENT Table of Contents Section... Page 1.0 Product Range...3 2.0 Description...3 3.0 Capabilities...3
More information1395 Node Adapter Board Troubleshooting
1395 Node Adapter Board Troubleshooting Specifications Electrical: Board power provided by Drive (+5V) Discrete Input 24V DC or 115V AC, jumper selectable Environmental: Ambient Operating Temperature Storage
More informationOperating instructions IO-Link master CabinetLine AL19xx
Operating instructions IO-Link master CabinetLine AL19xx 80273036/00 02/2018 1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 2 Safety instructions Read
More information4100/4120-Series Class A / Class B Zone Modules Installation Instructions
4100/4120-Series Class A / Class B Zone Modules Installation Instructions Introduction This publication describes the installation procedure for the following modules. Model Description Required Back Box
More information270 MHz Control Modules
2400 / 2420 / 2450 Performance Drives A D D E N D U M 270 MHz Control Modules Notices 2000.40(A2) 01 11/08 Copyright 2002-2008 by Unico, Incorporated. All rights reserved. No part of this publication may
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More information2T105. Multi Range Digital Setting Time Delay Relay. Features. Application. Operation
2T15 Multi Range Digital Setting Time Delay Relay Technical Bulletin Features Four time ranges -.99s, -9.9s, -99s, -99s High accuracy & repeatability timing compensated for output relay delay Time settings
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationistar Pro Installation Guide
istar Pro Installation Guide UM-241 Version A1 October 2010 istar Pro Installation Quick Start Guide System Components The istar Pro hardware components consist of: General Controller Module (GCM) A general
More informationMRS ELECTRONIC DATASHEET CAN 4 ANA DESCRIPTION TECHNICAL SPECIFICATION REGULATORY APPROVALS AND TESTING SOFTWARE/PROGRAMMING
DESRIPTION The Micro PL AN 4 ANA offers many possible applications with its 5 inputs and outputs. One analog input and four I/Os, the function of which can be individually defined. These inputs/outputs
More informationProduct Manual. Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip
Surge Protected Metal 7- Port USB 2.0 Hub DIN RAIL Mount Kit NEC Chip Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-7DU2i 2 USBG-7DU2i Product Manual Revision History Revision
More informationDS BAS /99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER FEATURES
DS 13.321 BAS 2800+ 06/99 UNC 596 BUILDING AUTOMATION SYSTEM UNIVERSAL NETWORK CONTROLLER Specification no. 579-1-904 The Universal Network Controller (UNC 596) is fully intelligent and incorporates its
More informationControl Panels B5512/B4512. en UL Installation Instructions
Control Panels B551/B451 en UL Installation Instructions Control Panels Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Related documentation 4 1. Bosch Security
More informationQuick Start Installation Guide
RM-iCLASS Series Quick Start Installation Guide Version C0 Document Part Number UM-208 June 2009 OVERVIEW The RM-iClass Quick Start Installation Guide provides a summary of installation and connection
More informationUniversal Expander Module in Low Profile Enclosure. P/N: INSTALLATION MANUAL
Revision 2.14 October. 2009 1 Overview Universal Module in Low Profile Enclosure. P/N: 995004 INSTALLATI MANUAL The Universal Module connects to a Model 3000/Access 4000 system OR a Model 2000 system,
More informationUSB-PDISO8/40. USB-based Isolated Input and Relay Output. User's Guide. September Rev 6 Measurement Computing Corporation
USB-PDISO8/40 USB-based Isolated Input and Relay Output User's Guide September 2017. Rev 6 Measurement Computing Corporation Trademark and Copyright Information Measurement Computing Corporation, InstaCal,
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationModel 2657A-LIM-3 LO Interconnect Module
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More informationMANUAL. Handgelenksband WST 100. Handgelenksband- und Schuhtester. performance test for Electrostatic Wrist Straps and Conductive Shoes
MANUAL Handgelenksband- und Schuhtester Handgelenksband WST 100 performance test for Electrostatic Wrist Straps and Conductive Shoes S 2 Handbuch WST 100 Contents Description... 2 Specification... 2 Function...
More informationInstalling Sentor. Hardware Installation
Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More informationVT805 / Monitoring system
Environmental Infrastructure monitoring VT805 / Monitoring system Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible
More informationHID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin
g GE Consumer & Industrial Multilin HID High Impedance Differential Module Instruction manual GEK-113064 Copyright 2005 GE Multilin GE Multilin 215 Anderson Avenue L6E 1B3 Markham, ON -CANADA T (905) 294
More informationMR50 READER INTERFACE
2.75 [69.9] 2.35 [59.7] U1 MR50 READER INTERFAE Installation and Specifications: 1. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEAH, A 90815-1755, (562)986-9105 FAX (562) 986-9205 This device
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationDIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E
INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More information2C138. Sensitive Earth Fault Relay. Features. Application. Operation
Technical Bulletin 2C138 Sensitive Earth Fault Relay Features High sensitivity (0.1% of I n ) 2 nd & 3rd harmonic & HF noise suppression - tuned to 50 Hz Optional reset functions Instantaneous (Fast),
More informationHIMatrix Safety-Related Controller Maintenance Manual
HIMatrix Safety-Related Controller Maintenance Manual HIMA Paul Hildebrandt GmbH + Co KG Industrial Automation Rev. 1.00 HI 800 455 E All HIMA products mentioned in this manual are protected by the HIMA
More informationExpansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157
PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or
More informationINPUTS: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)
INPUTS: All inputs: Inputs 1 to 24: Tamper: Panic: Fire: Keyswitch: 16-18VAC: Are 10K end of line monitored, with a response time of 300 ms. Alarm triggers SIREN, STROBE and REPORTING (depending on setup)
More informationArtistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0
Artistic Licence User Guide Serial nos. 4900 and upwards Version 5-0 Please read these instructions before using the product. This product has been designed & manufactured for professional use only. It
More information1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection
Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output
More informationINSTALLATION INSTRUCTIONS 923P EntryCheck TM
801 Avenida Acaso, amarillo, a. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS 923P Entryheck TM The Entryheck 923P Indoor/Outdoor Keypad is a surface
More informationTable of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4
Table of Contents 1 ABOUT THIS GUIDE... 3 1.1 CONTACT INFORMATION... 3 2 ANTENNA INSTALLATION... 4 2.1 GENERAL INFORMATION... 4 2.2 SPECIFIC MOUNTING EXAMPLES... 5 2.3 CONNECTOR MOISTURE PROTECTION...
More information16-Channel Digital Input Termination Card 24Vdc
TDI16AIA 16-Channel Digital Input Termination Card 24Vdc (TDI16AIA) Issue 3 October 2005 INTRODUCTION PURPOSE The TDI16AIA 16-channel digital input termination card acts as an interface between the digital
More informationCardaxFT Reader I/O Interface
CardaxFT Reader I/O Interface CardaxFT Reader I/O Interface provides I/O functionality and an interface for connecting Cardax readers to the CardaxFT system. CardaxFT Reader I/O Interface provides an interface
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder
More informationHXV SERIES HIGH VOLTAGE SWITCHING SYSTEMS
BULLETIN HXV (v) HXV SERIES HIGH VOLTAGE SWITHING SYSTEMS The HXV Series are computer controlled switching systems designed for High Voltage applications. Standard systems handle signals up to volts, while
More informationATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase
Characteristics variable speed drive ATV310-0.75 kw - 1 hp - 380...460 V - 3 phase Main Range of product Altivar Easy 310 Product or component type Product specific application Assembly style Device short
More informationSuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998
SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch
More informationEX-RC1 Remote I/O Adapter
EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter
More informationSUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA)
TECHNICAL SPECIAL PROVISION FOR SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM (SCADA) FINANCIAL PROJECT NO.: 428213-2-52-02 MARION COUNTY The official record of this Technical Special Provision is the
More informationOperating Instructions
Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward
More informationArtistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0
Artistic Licence Rail-Split extreme User Guide Serial numbers 151 upwards Version 5-0 Please read these instructions before using the product. This product has been designed & manufactured for professional
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationDigital I/O Module. Impro (DIO) Digital I/O Module INSTALLATION MANUAL
COMPONENT CODES: HMI700-1-0-NN-XX HMI701-1-0-NN-XX Digital I/O Module Impro (DIO) Digital I/O Module Specifications INSTALLATION MANUAL The DIO is a Cluster Expansion Module that works in conjunction with
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationWOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112
SELECTRONIX, INC. WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL Models: SLC2102-SLC2112 SLC2102X-SLC2112X SLC2152-SLC2162 SLC2170-xx Relay
More informationBeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:
BeagleBone Black USB Expansion RS232 Module Cape Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-2COM-BB 2 USB-2COM-BB Product Manual Revision History Revision Date Author Comments
More informationOperating Instructions
PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number
More information4100/4120-Series and 4010ES Relay Modules Installation Instructions
4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description
More informationModel HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET
Model /225 FOR ADDITIONAL INFORMATION SEE /225 DATA SHEET SPECIFICATIONS Accuracy*: ± 2% / ± 3% RH Range: 0-100% RH Hysteresis: ± 1% Supply Voltage:12-40 VDC 12-35 VAC (VDC output units only) Supply Current:
More informationIntel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide
Intel NUC Kit DN2820FYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers and with the safety
More informationAUTROFIELDBUS PROTOCOL CONVERTER BSD-321/1
UTROFIELDUS PROTOCOL CONVERTER SD-321/1 utrosafe Interactive Fire Detection System Product Datasheet Features Interfaces various types of flame and gas detectors with the utrosafe Integrated Fire and Gas
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationIntel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide
Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide 1 Before You Begin CAUTIONS The procedures in this user guide assume familiarity with the general terminology associated with personal computers
More informationUser Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide
Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK User Guide 1 Before You Begin CAUTIONS The steps in this guide assume you re familiar with computer terminology and with the safety practices and regulatory
More information