Assembly. Connection FEL 52 (E5) 3-wire DC connection (example) FEL 52 (E5) 0.5 A U V DC V DC

Size: px
Start display at page:

Download "Assembly. Connection FEL 52 (E5) 3-wire DC connection (example) FEL 52 (E5) 0.5 A U V DC V DC"

Transcription

1 Vibration Limit Switch Features Assembly Level limit switch for liquids Large selection of process connections: universal use Wide variety of electronic modules (e. g., relay, thyristor signal output): the right connection for every process control system No calibration: quick and low-cost start up No mechanically moving parts: maintenance-free, no wear, long operating life Monitoring of the vibrating fork for damage: guaranteed function PROFIBUS PA protocol: commissioning and maintenance quick and easy Up to SIL acc. to IEC 6508 Vibracon with plastic housing and process connection G** Vibracon with aluminium housing and process connection with flange Ø85 Ø80 max. 65 max. 55 L ~5 7.5 max. 76 max. 60 Function max. 7 The Vibracon is a level limit switch for use in all liquids. for temperature of -50 C ( K) to +50 C (4 K) for pressures up to 64 bar for viscosities up to 0000 mm²/s for densities up to 0.5 g/cm³ or 0.7 g/cm³ (other settings available on request) Additional dimensions see section dimensions. Length L see process connections. Ø.5 L max The function is not affected by flow, turbulence, bubbles, foam, vibration, bulk solids content or build-up, the Vibracon is thus the ideal substitute for float switches. The compact version is ideal for mounting in pipes (LVL-M). In addition there is a version with extension tube up to 6 m (0 ft) (LVL-M). High corrosion-resistant Alloy C4 (.460) is available for the vibration fork and process connection for applications in very aggressive liquids. EEx ia, EEx de and EEx d protection enable it to be used in hazardous areas. Connection Connection FEL 5 (E5) -wire DC connection (example) - preferably for use with memory programmable controls (PLC) - positive signal at the switch output of the electronics (PNP) - Output blocked on reaching limit level. - also in compact housing with plug connection available Other connection types see section electrical connection. 0.5 A FEL 5 (E5) (+) L+ L U... 0 V DC V DC e. g. relay PLC

2 Application Function principle Function and system design Measuring principle Input characteristics Measured variable Measurement range Medium density Output characteristics Fail-safe mode Switching time Switch-on response Auxiliary energy Supply voltage Limit detection maximum or minimum detection in tanks or pipelines containing liquids of any kind, even in hazardous areas The forks of the sensors vibrate at their intrinsic frequency. This frequency is reduced when covered with liquid. The change in frequency then activates the limit switch. limit level (limit value) LVL-M: depends on mounting point LVL-M: depends on mounting point and pipe extension up to 6000 mm (0 ft) adjustment on the electronic insert > 0,5 g/cm or > 0,7 g/cm (other on request) switch-over for minimum/maximum residual current safety on electronic insert MAX = maximum safety: The output switches to the power fail response when the fork is covered. for use with overspill protection for example MIN = minimum safety: The output switches to the power fail response when the fork is exposed. for use with dry running protection for example when fork is covered: approx. 0.5 s, when fork is exposed: approx..0 s (other switching times on request) additionally configurable for PROFIBUS PA (electronic insert FEL50A (PA)): s When switching on the power supply the output assumes the alarm signal. After max. s it assumes the correct switching mode. electronic insert FEL50A (PA): 9... V DC electronic insert FEL5 (AC): 5 V AC, 50/60 Hz electronic insert FEL5 (E5): V DC electronic insert FEL54 (WA): V AC, 50/60 Hz or V DC electronic insert FEL55 (SI):... 6 V DC, PLC electronic insert FEL56 (N), FEL58 (N): isolating amplifier acc. to EN (NAMUR) Connecting cable electronic inserts: cross section max..5 mm, lace in end splice in acc. with DIN 468 ground lead in housing: cross section max..5 mm external equipotential bonding: cross section 4 mm Power consumption electronic insert FEL5 (E5): max. 0.8 W electronic insert FEL54 (WA): max.. W Current consumption electronic insert FEL5 (E5): max. 5 ma Measurement accuracy Reference operating conditions ambient temperature: C (7.4 F), medium temperature: C (7.4 F), product density: g/cm (water), viscosity: mm /s, medium pressure p e : 0 bar, sensor mounting: vertical from above, density switch: to > 0.7 g/cm Maximum measured error max. ± mm, specified by mounting position Non-repeatability 0. mm Hysteresis approx. mm Influence of medium density max mm ( g/cm ) Influence of medium temperature max mm ( C ( F)) Influence of medium pressure max mm ( bar) Operating conditions Installation conditions Installation position LVL-M: any position LVL-M: with short pipe (up to 500 mm (9.7 inch)) any position, with long pipe vertical Ambient conditions Ambient temperature C (... 4 K), function with reduced data values see section ambient temperature Storage temperature C (... 5 K) Overvoltage protected electronic insert FEL5 (AC), electronic insert FEL5 (E5), electronic insert FEL54 (WA), electronic insert FEL55 (SI): overvoltage category III Process conditions Medium temperature C ( F), for exceptions see process connections Medium pressure p e = bar ( psi) over the entire temperature range, exceptions see process connections Test pressure max. 00 bar (.5 times the medium pressure p e ), no function during test pressure, burst pressure of diaphragm 00 bar Thermal shock resistance max. 0 C/s (max. 0 K/s) State of aggregation liquid Density min. 0.5 g/cm (compact housing 0.7 g/cm ), other density settings on request Viscosity max mm /s (max cst) Solid contents max. Ø 5 mm Mechanical specifications

3 Degree of protection Mechanical construction Construction type Dimensions Mass polyester, steel, and aluminum housing: IP66/IP67 compact housing: - IP65 with valve connector PG or /NPT - IP66/IP68 with M x connector without LEDs (.445/6L) - IP69K with M x connector with LEDs (.445/6L) LVL-M: compact design LVL-M: version with extension tube housing: diameter max. 85 mm, height max. 7 mm temperature separator, flameproof bushing: additional length L 40 mm process connection: length L mm extension: any length L from mm, depending on the process connection extension: length type II, for vertical installation from above same switching point as Vibracon LVL, LVL vibration fork: width 7.5 mm, fork width 0 mm, length 5 mm 600 g, basic weight: compact sensor, electronic insert, stainless steel housing, process connection G*, additional weight is dependent on extension tube, housing and process connection Additional weight process connections: - A* 000 g, A4* 00 g, A5* 500 g, A6* 400 g, A g, A g, A g, A g, A9.5 kg, A9 7. kg - C g, C5 00 g, C7 600 g, C75 00 g, C g, CA 5600 g - D g, D5 00 g, D7 600 g, D75 00 g, D7A 00 g, D7D 00 g, D g, DA 5600 g - F g, F5 00 g, F g, F6 400 g, F g, F7 600 g, F75 00 g, F7F 600 g, F8 400 g, F g, F g, F g, FA 5600 g, FA g - G* 00 g - J no information, J6 no information, J7 700 g, J9 no information, JA no information, JC 700 g - N* 00 g, N g - R* 00 g - T5 no information, T6 00 g extension tube, tempeprature spacers, flameproof bushings: - B* 900 g/m, C* 00 g/00 inch - D* 00 g - J* 900 g/m and 600 g, K* 00 g/00 inch and 600 g - L* 700 g - R* 900 g/m and 700 g, S* 00 g/00 inch and 700 g - T* 800 g Material wetted parts: - process connection and extension tube:.445/6l or.460/alloy C4 - vibration fork:.445/6l or.460/alloy C4 - flat seal for process connection G* or G*: elastomer fibre, asbestos-free housings: - polyester housing: PBT-FR with PBT-FR cover or with PA cover with sight glass, cover seal: EPDM - stainless steel housing:.445/6l, cover seal: silicone - aluminum housing: EN-AC-AlSi0Mg, plastic-coated, cover seal: EPDM - compact housing with valve connector or M connector:.445/6l cable gland: polyamide or brass, nickel-plated temperature spacer:.445/6l flameproof bushing:.445/6l Surface quality R a <. µm/80 grit: length, spacer, bushings *A, *B, *E Switching point see section switch point Process connection - cylindrical thread G/4A, GA to DIN ISO 8/ with flat seal to DIN conical thread R/4, R to DIN 999, part - conical thread /4NPT, NPT to ANSI B.0. - flush-mounted with welding sleeve to factory standard (G/4A, GA) - flush-mounted with welding neck to factory standard ( inch), sensor can be positioned - Triclamp -/ inch, inch to ISO 85 - flanges to EN 09- from DN5, to ANSI B 6.5 from inch, to JIS B 8 (RF) from DN5 For further information see type code. Indication and operation Display elements electronic inserts: - electronic inserts FEL50 A (PA), FEL58 (N): green LED, yellow LED - electronic inserts FEL5 (AC), FEL5 (E5), FEL54 (WA), FEL55 (SI), FEL56 (N): green LED, red LED compact housings: compact housing with valve connector - electronic version FEL5 (AC), FEL5 (E5): green LED, red LED - electronic version FEL58 (N): green LED, yellow LED compact housing with M x round connector without LEDs - electronic version FEL5 (E5): green LED, yellow LED, red LED - electronic version FEL58 (N): green LED, yellow LED compact housing with M x round connector with LEDs - electronic version FEL5 (E5): green LED, two yellow LEDs Control elements electronic insert FEL50A (PA): 8 switches for device address setting electronic inserts FEL5 (AC), FEL5 (E5), FEL54 (WA), FEL55 (SI), FEL56 (N): two switches for fail-safe mode and density change electronic insert FEL58 (N): two switches for fail-safe mode and density change and one test button interrupts lead

4 Function test Certificates and approvals Explosion-hazardous area compact housing: function test with test magnet electronic versions FEL5 (AC), FEL5 (E5) and FEL58 (N): During the test, the current state of the electronic switch is reversed. KEMA 0 AT 089, KEMA 0 AT 47 X, KEMA 0 AT 7, for additional certificates see Type of protection II /G EEx ia IIC T... T6 or EEx ia IIB T... T6 and II /D T80 C (KEMA 0 AT 089) II G EEx ia IIC T... T6 or EEx ia IIB T... T6 (KEMA 0 AT 47 X) II /G EEx d IIC T... T6 or EEx d IIB T... T6 (KEMA 0 AT 7) II G EEx na/nc II T6 and II D T85 C SIL classification up to SIL acc. to IEC 6508 Overspill protection Z (overspill protection in acc. with WHG) General information Directive conformity Directive 7//EEC EN 600- (Low Voltage Directive) Directive 89/6/EEC (EMC) emitted interference to EN 66, class B equipment noise immunity to EN 66, annex A (industrial sector) If the fork tines are joined together on account of build-up, the useful signal is attenuated to such an extent that the original EMC values can no longer be completely observed (EN electromagnetic fields, EN HF coupling). Directive 94/9/EC (AT) EN 5004, EN 5008, EN 50000, EN 5000, EN 5084, EN Conformity Electromagnetic compatibility NE Degree of protection EN 6059 Climate class EN 60068, part -8, fig. a Vibration resistance EN , Hz, 0.5 mm, 00 cycles Supplementary documentation Supplementary information technical information TI8O operating instructions KA4O () operating instructions KA0O (* with compact housing) operating instructions BA4O (electronic insert FEL50A (PA)) operating instructions KA40O weld-in socket G (LVL-Z0) operating instructions KA4O weld-in adapter G (LVL-Z0) operating instructions KA4O weld-in adapter G¾ (LVL-Z00) operating instructions KA5O sliding sleeve for unpressurised operation GA, NPT (LVL-Z0, LVL-Z) operating instructions KA5O sliding sleeve for unpressurised operation G½A, ½ NPT (LVL-Z, LVL- Z) operating instructions KA5O high pressure sliding sleeve GA, NPT (LVL-Z4, LVL-Z5, LVL-Z8, LVL-Z9) operating instructions KA54O high pressure sliding sleeve GA, NPT (LVL-Z6, LVL-Z7, LVL-Z0, LVL-Z) safety information SI0O (KEMA 0 AT 7) safety information SI06O (KEMA 0 AT 089) safety information SI064O (KEMA 0 AT 47 X) safety information SI54O (KEMA 0 AT 089), PROFIBUS PA version safety information SI59O (KEMA 0 AT 47 X), PROFIBUS PA version safety information SI8O ( II G EEx na/nc II T6 and II D T85 C) approval ZEO overspill protection acc. to WHG (Z ) FM installation drawing ZD04O CSA control drawing ZD04O EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see Ambient temperature Permissible ambient temperature T at the housing depends on the product temperature T in the vessel: * additional temperature range for sensors with a temperature separator or pressure-tight bushing T T T * 70 C 50 C 0 C -50 C 0 C 50 C 00 C 50 C 90 C -50 C T 4

5 Switch point Switch point on the sensor depend on the mounting position, with reference to water, density g/cm³, C (96 K), p e 0 bar. Note: The switch points of the Vibracon LVL-MC are at other positions to those of the previous versions LVL, LVL. mm (0.5 in) 4 mm (0.6 in) 4 mm (0.6 in) Mounting from above Mounting from below Mounting from the side 5

6 Electrical connection Electronic insert FEL50A (PA) Two-wire connection for power supply and data transfer for connecting to PROFIBUS PA FEL50A (PA) Additional functions: Digital communication enables the representation, reading and editing of the following parameters: fork frequency, switch-on frequency, switch-off frequency, switch-on time and switch-off time, status, measured value, density switch. Matrix locking possible. Switch to WHG mode possible (WHG approval). You can also visit for more information. PA- PA+ PROFIBUS PA U 9 V DC... V DC Segment coupler Electronic insert FEL5 (AC) Two-wire AC connection Always connect in series with a load! FEL5 (AC) Check the following: the residual current in blocked state (up to.8 ma) that for low voltage - The voltage drop across the load is such that the minimum terminal voltage at the electronic insert (9 V) when blocked is not undershot. - The voltage drop across the electronics when switched through is observed (up to V). that a relay cannot de-energise with holding power below.8 ma If this is the case, a resistor should be connected parallel to the relay (RC module available on request). When selecting the relay, pay attention to the holding power/rated power (see connectable load). A min. 9 V L external load U~ max. 5 V AC, 50/60 Hz N N PE 6

7 Electrical connection Electronic FEL5 (AC) in compact housing Connection MAX MIN Housing C (½ NPT) or Housing C6 (PG) > 9 V > 9 V R R.0 A.0 A PE L (Ground) N PE L (Ground) N Electronic insert FEL5 (E5) Three-wire DC connection preferably used with programmable logic controllers (PLC), DI module as per EN 6-. positive signal at switching output of the electronics (PNP) Output blocked on reaching limit. FEL5 (E5) (+) 0.5 A e. g. relay PLC L+ L U 0 V DC 55 V DC Electronic FEL5 (E5) in compact housing Connection MAX MIN Housing C4 (M x ), connector with LEDs (WT) (BN) (WT) (BN) (BU) 4 (BK) (BU) 4 (BK) Housing C4 (M x ), connector without LEDs Housing C (½ NPT) or Housing C6 (PG) R R 0.5 A 0.5 A L L+ L L+ + + R R 0.5 A 0.5 A PE L L+ PE L (Ground) (Ground) L+ 7

8 Electrical connection Electronic insert FEL54 (WA) Universal current connection with relay output Power supply: Please note the different voltage ranges for AC and DC. Output: When connecting an instrument with high inductance, provide a spark arrester to protect the relay contact. A fine-wire fuse (depending on the load connected) protects the relay contact on short-circuiting. Both relay contacts switch simultaneously. FEL54 (WA) * When jumpered, the relay output works with NPN logic. * 0.5 A L L+ N L PE a u r a u r U~ 9 V AC 5 V AC, 50/60 Hz U 9 V DC 55 V DC Electronic insert FEL55 (SI) Two-wire connection for separate switching unit for connecting to programmable logic controllers (PLC) for example, AI module 4 ma... 0 ma to EN 6- Output signal jump from high to low current on limit (H-L edge) FEL55 (SI) EEx ia I U V DC 6 V DC e. g. PLC + 8

9 Electrical connection Electronic insert FEL56 (N) Two-wire connection for separate switching unit for connecting to isolating amplifiers acc. to NAMUR (IEC ), e. g. isolating amplifier KFD-SR-Ex.W or remote process interface KSD-BI-Ex from Pepperl+Fuchs Output signal jump from low to high current on limit (L-H edge) FEL56 (N) Connecting to multiplexer: set clock time to min. s. EEx ia I + Isolated switch amplifiers according to IEC (NAMUR) Electronic insert FEL58 (N) Two-wire connection for separate switching unit for connecting to isolating amplifiers acc. to NAMUR (IEC ), e. g. Isolating amplifier KFD-SR-Ex.W or remote process interface KSD-BI-Ex from Pepperl+Fuchs Output signal jump from high to low current on limit (H-L edge) FEL58 (N) Additional function: Test key on the electronic insert. Pressing the key breaks the connection to the isolating amplifier. Connecting to multiplexer: set clock time to min. s. EEx ia Note For Ex-d applications, the additional function can only be used if the housing is not exposed to an explosive atmosphere. I + Isolated switch amplifiers according to IEC (NAMUR) 9

10 Electrical connection Electronic FEL58 (N) in compact housing Connection MAX MIN Housing C4 (M x ), connector with LEDs (WT) (BN) (WT) (BN) (BU) 4 (BK) (BU) 4 (BK) Housing C4 (M x ), connector without LEDs + + Housing C (½ NPT) or Housing C4 (PG) + + 0

11 Dimensions Compact housing C* 0 40 Ø40 4 Ø40 AF AF * Stainless steel housing E* Ø76 max. 64 L max. 50 length L see process connections Process connections A**, C**, D**, F**, J**, N75 G* G* GE N* N* R* R* (66.5) (69) 50.5 (66.5) (69) 50.5 T** 66.5

12 Dimensions Extension tube Thread: G¾A GA Thread: ¾ NPT NPT R¾ R Flanges and flange-like process connections Vibration fork L Ø.5 L Ø.5 L Ø.5 from seal surface of thread adapter from lower egde of thread Ø.5 ~5 max

13 Accessories Welding sleeves LVL-Z00, welding sleeve G¾ for flush mounting for process connection G LVL-Z0, welding sleeve G for flush mounting for process connection GE LVL-Z0, welding sleeve G for flush mounting for process connection GE Flanges LVL-Z05, lap joint round flange DN50 PN40 form A with G thread for process connection G LVL-Z06, lap joint round flange ANSI " with G thread for process connection G LVL-Z07, lap joint square flange with G thread for process connection G Sliding sleeves LVL-Z0, sliding sleeve for unpressurised operation GA LVL-Z, sliding sleeve for unpressurised operation G½A LVL-Z, sliding sleeve for unpressurised operation NPT LVL-Z, sliding sleeve for unpressurised operation ½ NPT LVL-Z4, high pressure sliding sleeve GA LVL-Z5, high pressure sliding sleeve GA, Alloy C4/.460 LVL-Z6, high pressure sliding sleeve G½A LVL-Z7, high pressure sliding sleeve G½A, Alloy C4/.460 LVL-Z8, high pressure sliding sleeve NPT LVL-Z9, high pressure sliding sleeve NPT, Alloy C4/.460 LVL-Z0, high pressure sliding sleeve ½ NPT LVL-Z, high pressure sliding sleeve ½ NPT, Alloy C4/.460 Further accessories LVL-Z08, cover with glass sight glass for stainless steel housing E* LVL-Z09, cover with PC sight glass for stainless steel housing E* LVL-Z0, transparent cover for polyester housing P* V-G, mating connector, straight V-W, mating connector, 90 angled

14 Type code/model number L V L M Specification of length without unit for design M Certificates NA for non-hazardous areas WH WHG overspill protection E II G EEx ia IIC T6 E II /G EEx ia IIC T6 E II /G EEx d IIC T6 EA II G EEx ia IIC T6, WHG EB II /G EEx ia IIC T6, WHG EC II /G EEx d IIC T6, WHG EN II G EEx nc IIC T6, WHG EM II G EEx na IIC T6, WHG FI FM, IS, CI I, II, III, Div, Group AG FN FM, NI, CI I, Div, Group AD FX FM, XP, CI I, II, III, Div, Group AG CG CSA, General Purpose CI CSA, IS, CI I, II, III, Div, Group AG CX CSA, XP, CI I, II, III, Div, Group AG Optional equipment NA without optional equipment Z..B material, wetted parts.445, inspection certificate to EN 004 Electronic insert PA FEL50 A, PROFIBUS PA AC FEL5, contactless -wire switch, 9 V AC... 5 V AC E5 FEL5, PNP -wire, 0 V DC V DC WA FEL54, potential-free change-over contact, DPDT, 9 V AC... 5 V AC, 9 V DC V DC SI FEL55, 8/6 ma, V DC... 6 V DC N FEL56, NAMUR, L-H edge N FEL58, NAMUR with push button, H-L edge Housing, cable entry A aluminium housing, IP66, cable gland M0 A aluminium housing, Nema 4x, ¾ NPT A aluminium housing, IP66, entry G½A A4 aluminium housing, IP66, plug connector M x A5 aluminium housing, IP66, PA plug connector M x C compact housing, Nema 4x, ½ NPT plug connector,.445/6l C4 compact housing, IP66, plug connector M x,.445/6l C6 compact housing, IP66, PG plug connector,.445/6l E stainless steel housing, IP66, cable gland M0 E stainless steel housing, Nema 4x, ½ NPT E stainless steel housing, IP66, entry G½A E4 stainless steel housing, IP66, plug connector M x E5 stainless steel housing, IP66, PA plug connector M x P polyester housing, IP66, cable gland M0 P polyester housing, Nema 4x, ½ NPT P polyester housing, IP66, entry G½A P4 polyester housing, IP66, plug connector M x P5 polyester housing, IP66, PA plug connector M x Length, temperature spacer, pressure-tight bushing design M AA 66 mm/.6 in, R a <. µm/80 grit design M IA 66 mm/.6 in, R a <. µm/80 grit, with temperature spacer design M QA 66 mm/.6 in, R a <. µm/80 grit, with pressure-tight bushing design M BB mm L.445/6L, R a <. mm/80 grit design M BE mm L.460/Alloy C4, R a <. mm/80 grit design M CB in L.445/6L, R a <. mm/80 grit design M CE in L.460/Alloy C4, R a <. mm/80 grit design M DB special length L II,.445/6L, R a <. mm/80 grit, switch point = Vibracon compact design M DE special length L II,.460/Alloy C4, R a <. mm/80 grit, switch point = Vibracon compact design M JB mm L.445/6L, with temperature spacer design M JE mm L.460/Alloy C4, with temperature spacer design M KB in L.445/6L, with temperature spacer design M KE in L.460/Alloy C4, with temperature spacer design M LB special length L II,.445/6L, with temperature spacer, switch point = Vibracon compact design M LE special length L II,.460/Alloy C4, with temperature spacer, switch point = Vibracon compact design M RB mm L.445/6L, with pressure-tight bushing design M RE mm L.460/Alloy C4, with pressure-tight bushing design M SB in L.445/6L, with pressure-tight bushing design M SE in L.460/Alloy C4, with pressure-tight bushing design M TB special length L II,.445/6L, with pressure-tight bushing, switch point = Vibracon compact design M TE special length L II,.460/Alloy C4, with pressure-tight bushing, switch point = Vibracon compact Design M compact design M extended design (48 mm/6 in... 6,000 mm/0 ft) Continued on next page. 4

15 Type code/model number L V L M Process connection and material A ", ANSI B 6.5, 50 lbs RF,.445/6L A4 ¼", ANSI B 6.5, 50 lbs RF,.445/6L A4 ¼", ANSI B 6.5, 00 lbs RF,.445/6L design M A5 ½", ANSI B 6.5, 50 lbs RF,.445/6L A5 ½", ANSI B 6.5, 50 lbs RF,.445/6L design M A6 ", ANSI B 6.5, 50 lbs RF,.445/6L A6C ", ANSI B 6.5, 50 lbs RF, Alloy C4, platinised A6 ", ANSI B 6.5, 00 lbs RF,.445/6L design M A6 ", ANSI B 6.5, 600 lbs RF,.445/6L design M A7 ½", ANSI B 6.5, 00 lbs RF,.445/6L design M A8 ", ANSI B 6.5, 50 lbs RF,.445/6L A8 ", ANSI B 6.5, 00 lbs RF,.445/6L design M A9 4", ANSI B 6.5, 50 lbs RF,.445/6L A9 4", ANSI B 6.5, 00 lbs RF,.445/6L design M A9 4", ANSI B 6.5, 600 lbs RF,.445/6L design M F45 DN5 PN5/40 A, EN 09-,.445/6L F5 DN PN6 A, EN 09-,.445/6L F55 DN PN5/40 A, EN 09-,.445/6L F6 DN40 PN6 A, EN 09-,.445/6L F65 DN40 PN5/40 A, EN 09-,.445/6L F7 DN50 PN6 A, EN 09-,.445/6L F75 DN50 PN5/40 A, EN 09-,.445/6L F8 DN65 PN6 A, EN 09-,.445/6L F85 DN65 PN5/40 A, EN 09-,.445/6L F9 DN80 PN0/6 A, EN 09-,.445/6L F95 DN80 PN5/40 A, EN 09-,.445/6L FA DN00 PN0/6 A, EN 09-,.445/6L FA5 DN00 PN5/40 A, EN 09-,.445/6L D45 DN5 PN5/40 B, EN 09-,.445/6L C45 DN5 PN5/40, EN 09-,.460/Alloy C4,.445/6L, platinised D5 DN PN6 B, EN 09-,.445/6L C5 DN PN6, EN 09-,.460/Alloy C4,.445/6L, platinised D7 DN50 PN6 B, EN 09-,.445/6L C7 DN50 PN6, EN 09-,.460/Alloy C4,.445/6L, platinised D75 DN50 PN5/40 B, EN 09-,.445/6L C75 DN50 PN5/40, EN 09-,.460/Alloy C4,.445/6L, platinised D95 DN80 PN5/40 B, EN 09-,.445/6L C95 DN80 PN5/40, EN 09-,.460/Alloy C4,.445/6L, platinised DA DN00 PN0/6 B, EN 09-,.445/6L CA DN00 PN0/6, EN 09-,.460/Alloy C4,.445/6L, platinised F7F DN50 PN40 C, EN 09-,.445/6L N75 DN50 PN40 D, EN 09-,.445/6L RC R¾ BSP, DIN 999,.460/Alloy C4, platinised R R BSP, DIN 999,.445/6L RC R BSP, DIN 999,.460/Alloy C4 N ¾ NPT, ANSI B.0.,.445/6L NC ¾ NPT, ANSI B.0.,.460/Alloy C4 N NPT, ANSI B.0.,.445/6L NC NPT, ANSI B.0.,.460/Alloy C4 G G¾, DIN ISO 8/, BSP,.445/6L, mounting for welded sleeve design M GC G¾, DIN ISO 8/, BSP,.460/Alloy C4 G G, DIN ISO 8/, BSP,.445/6L GC G, DIN ISO 8/, BSP,.460/Alloy C4 GE G, DIN ISO 8/, BSP,.445/6L, mounting for welded sleeve J 0K 5A, JIS B 8 RF,.445/6L J6 0K 40A, JIS B 8 RF,.445/6L J7 0K 50A, JIS B 8 RF,.445/6L JC 0K 50A, JIS B 8 RF,.460/Alloy C4, platinised J9 0K 80A, JIS B 8 RF,.445/6L JA 0K 00A, JIS B 8 RF,.445/6L N75 DN50 PN40, EN 09-, groove,.445/6l T5 ½", DN5-8, Triclamp ISO 85,.445/6L T6 ", DN40-5, Triclamp ISO 85,.445/6L XXX special version Design M compact design M extended design (48 mm/6 in... 6,000 mm/0 ft) 5

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage. Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text

More information

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2 PROCESS AUTOMATION TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2 Vibration Limit Switch Limit Switch for Bulk Solids ISO9001 With regard to the supply of products, the current issue of the following document

More information

Liquiphant T FTL20. Technical Information. Level limit switch for liquids

Liquiphant T FTL20. Technical Information. Level limit switch for liquids Technical Information Liquiphant T FTL0 Level limit switch for liquids Application The Liquiphant T FTL0 is a level limit switch for all kinds of fluids and is used in tanks, containers and pipelines.

More information

Assembly. Function 41

Assembly. Function 41 Capacitive limit switch Features Assembly Limit switch for liquids and bulk solids Device with rod probe Complete unit consisting of the probe and electronic insert Integrated active build-up compensation:

More information

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES For liquids and solids NIVOSWITCH VIBRATING FORK LEVEL SWITCHES OUR PROFESSION IS YOUR LEVEL LEVEL SWITCHES O U R P R O F E S S I O N I S NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini

More information

Liquipoint T FTW31, FTW32

Liquipoint T FTW31, FTW32 TI00375F/00/EN/14.16 71336942 Products Solutions Services Technical Information Liquipoint T FTW31, FTW32 Conductive Point level switch for multiple point detection in conductive liquids Applications The

More information

FOR LIQUIDS AND SOLIDS

FOR LIQUIDS AND SOLIDS FOR LIQUIDS AND SOLIDS LEVEL SWITCHES VIBRATING FORK LEVEL SWITCHES O U R P R O F E S S I O N NIVOSWITCH VIBRATING FORK LEVEL SWITCHES MAIN FEATURES and mini compact type Rod extension up to 3 meters (10

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

LS 5000 series Vibration Level Switch for liquids

LS 5000 series Vibration Level Switch for liquids Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,

More information

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids Technical Information Level limit switch for multiple point detection in conductive liquids Applications The Liquipoint T sensors are used in conductive liquids (down to 0 µs/cm) for determining level

More information

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Level sensor Stainless steel version Model RLT-1000, for industrial applications Level measurement Level sensor Stainless steel version Model RLT-1000, for industrial applications WIKA data sheet LM 50.02 Applications Level measurement of liquids in machine building Control and monitoring

More information

Soliphant M FTM50, FTM51, FTM52

Soliphant M FTM50, FTM51, FTM52 Technical Information Soliphant M FTM50, FTM51, FTM52 Level limit switch Universal vibration limit switch for powder and fine-grained bulk solids, also for explosion-hazardous areas Application The Soliphant

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional

More information

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31 Level instruments Overview The unique modular design of the provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Level limit switch Series RF 3000 Selection list. Overview 2

Level limit switch Series RF 3000 Selection list. Overview 2 Table of content Overview 2 Page Applications 4 ------------------------------------------------------------------------------------------------------------- RF 3100 6 Standard version -------------------------------------------------------------------------------------------------------------

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

Capacitance level switches LS 210 LS 220

Capacitance level switches LS 210 LS 220 KROHNE 03/2001 7.02374.31.00 GR/PRINTO Capacitance level switches Compact switches for liquids, solids, slurry, foam and interface; outstanding performance for a low price Easy to install, no moving parts,

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

TECHNICAL INFORMATION Vibracon LVL-A7

TECHNICAL INFORMATION Vibracon LVL-A7 PROCESS AUTOMATION TECHNICAL INFORMATION Vibracon LVL-A7 Vibration Limit Switch Limit Switch for Liquids ISO900 With regard to the supply of products, the current issue of the following document is applicable:

More information

LS 6600 Technical Datasheet

LS 6600 Technical Datasheet Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE 06/2011-4001367301

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M low sensor MAG P Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Magnetic float switch For vertical installation Model FLS

Magnetic float switch For vertical installation Model FLS Level measurement Magnetic float switch For vertical installation Model FLS WIKA data sheet LM 30.01 for further approvals see page 3 Applications Level measurement for almost all liquid media Pump and

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Easy maintenance because modules can be exchanged rapidly Effective separation of measurement from plant vibration

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Level measurement. Applications. Special features. Description

Level measurement. Applications. Special features. Description Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on araday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Material Seat seal. N/en

Material Seat seal. N/en 0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N

Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N T T SD00170F/00/EN/13.13 71238754 Products Solutions Services Functional safety manual Liquiphant M/S with FEL58 and Nivotester FTL325N [Ex ia] [Ex ia] FTL325N FTL325N CH2 CH3 CH2 CH3 Level Limit Measuring

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Technical Information Liquipoint FTW23

Technical Information Liquipoint FTW23 TI0202F/00/EN/04.6 736230 Products Solutions Services Technical Information Capacitance point level measurement Point level switch for liquids in the food and beverage industry Application The is a point

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

Float switch For industrial applications Model RLS-1000

Float switch For industrial applications Model RLS-1000 Level measurement Float switch For industrial applications Model RLS-000 WIKA data sheet LM 50.0 Applications Level measurement of liquids in machine building Control and monitoring tasks for hydraulic

More information

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Inductive sensor BI5-EM18-Y1X-H1141

Inductive sensor BI5-EM18-Y1X-H1141 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication Series 3731 Electropneumatic Ex d Positioner Type 3731-5 with FOUNDATION TM Fieldbus communication Application Positioner for attachment to pneumatic control valves Travel: 3.6 to 200 mm Opening angle:

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet sales@jumo.co.uk info.us@jumo.net Page 1/9 JUMO PINOS L01 Calorimetric flow sensor Brief description The JUMO PINOS L01 flow sensor serves the measuring and monitoring of flow velocities of water and aqueous

More information

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

MANUAL LML-P, LML-S, LML-Ex

MANUAL LML-P, LML-S, LML-Ex PROCESS AUTOMATION MANUAL LML-P, LML-S, LML-Ex Magnetic Immersion Probe for Limit Value Detection ISO9001 With regard to the supply of products, the current issue of the following document is applicable:

More information

Level measurement CleverLevel LBFI Point level detection

Level measurement CleverLevel LBFI Point level detection User Product benefits highlights Safe detection of liquids, bulk solids and powders Short immersion length Capable of differentiation between foam and liquid Insensitive to adherent or sticky media Status

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.

More information

Limit switches for Dial Thermometers and Pressure gauges

Limit switches for Dial Thermometers and Pressure gauges JJ Direct limit switches JJ Indirect limit switches JJ Multifunction relays Limit switches for Dial Thermometers and Pressure gauges DS_Limit_switches 08/2015 349 Limit switches Limit switches are optional

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

OPTISWITCH 6600 C Technical Datasheet

OPTISWITCH 6600 C Technical Datasheet Technical Datasheet Microwave Level Switch for standard hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Small and compact KROHNE CONTENTS

More information

A TECHNOLOGY FOR EVERY LEVEL APPLICATION

A TECHNOLOGY FOR EVERY LEVEL APPLICATION INSTRUCTION MANUAL A TECHNOLOGY FOR EVERY LEVEL APPLICATION NIVOSWITCH R0/R500 VIBRATION FORK LEVEL SWITCHES Dual purpose level switch with intelligent electronics applicable for: almost all liquids light,

More information

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M12 x 1 Chrome-plated brass Rated operating distance 90 mm with DMR31-15-5 magnet DC 2-wire, nom.

More information

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Series 3731 Type 3731-5 Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow

More information

Product information Ultrasonic

Product information Ultrasonic Product information Ultrasonic Level measurement in liquids and bulk solids VEGASON 6 VEGASON 6 VEGASON 6 Document ID: 90 Contents Contents Measuring principle... Type overview... 4 Instrument selection...

More information

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transducers Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

21023, 21025, 2/2 Direct solenoid actuated poppet valves

21023, 21025, 2/2 Direct solenoid actuated poppet valves 03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASWING 71 A Contents Contents Safety information... 2 1 Product description 1.1 Function and configuration... 3 1.2 Functional principle... 3 1.3 Technical data...

More information

26360, NAMUR. Technical data

26360, NAMUR. Technical data 66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual

More information

MANUAL Vibracon LVL-A7

MANUAL Vibracon LVL-A7 PROCESS AUTOMATION MANUAL Vibracon LVL-A7 Vibration Limit Switch Limit Switch for Liquids ISO900 With regard to the supply of products, the current issue of the following document is applicable: The General

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs Overview This document provides information relating to the use of THE BARRIER HiC2, the SMART universal barrier from Pepperl+Fuchs, a

More information