DPS INC. TL1 4-Port MUX. Operation Guide TABLE OF CONTENTS. Overview

Size: px
Start display at page:

Download "DPS INC. TL1 4-Port MUX. Operation Guide TABLE OF CONTENTS. Overview"

Transcription

1 DPS INC "Your Partners in Telemetry Monitoring Systems" TABLE OF CONTENTS Overview.... Functional Schematic... Typical MUX Applications... Shipping List... Installation... and SWT Buttons... LED Display Status... DIP Switches... Specifications... Options & Model Numbers.... TL - MUX Operation Guide Overview Fig. - TL - MUX Coordinates Data from TL ports onto a The DPS TL - MUX is a specialized data multiplexer for combining up to data lines using Bellcore (tm) Transaction Language (TL) onto a single TL line. By observing the delineating semi-colon at the end of each TL data packet, the processor in the TL - MUX is able to store and stack incoming data. The TL packets are then sent to the common port in the order received and transmitted to thetl interrogator or master one-at-a-time. AID and TID information, as well as alarm data, remains intact, giving the interrogating master undisturbed and complete alarm data. Incoming packets are stored in a 6 K buffer. Packets from the interrogator side are broadcast to all remotes, with full address information. The TL - MUX consists of five interface ports interconnected and controlled by a processor. Associated with one port (the common or MUX port) is a communications subassembly that allows the physical interface for that port to be configured to match the associated communications channel or device (RS, RS/85 or 0 modem). This model of the TL - MUX is equipped with RS interfaces on the other ports (-). The TL - MUX is housed on a plug-in board that fits in a 00-Type card housing. The back of the housing provides appropriate connectors for interfacing the associated devices. The actual MUX board can be changed rapidly without removing any of the connections. The front panel of the TL - MUX provides LEDs for monitoring unit activity. The TL - MUX operates on either - or -8 Volts DC, depending on the option. (Options are described in the Options and Model Numbers section of page.) Change Notice This Operation Guide is a new publication. Any future changes will be noted in this box. Vertical bars in the margins denote changes. Copyright 996, DPS, Inc. All rights reserved. Printed in U.S.A. D-MAS-6070-V OG0866 June 996

2 Functional Schematic The illustration in Fig. shows a functional schematic of the MUX. Typical MUX Applications The illustration in Fig. shows the TL - MUX interfacing Network Elements to a TL Operational System. The illustration in Fig. shows three TL - MUX cards cascaded to provide a total of 0 TL ports at a single location. TL Network Elements TLMUX To OSS Fig. - Four Network Elements Feed One OS D RTS CTS D GND 5 (MUX ) RS & 0 / RS RS D 7 RTS 9 CTS 6 D 8 GND 0 Communications Subassembly 5- / DTR 5 +/D 55 - / D 56 +/D D RTS CTS D GND 5 D RTS CTS D GND 5 -BATT. 5 GND 7 Pin No LED's Power Regulator *Subassembly Pin-Outs RS- DTR D (BA) D C (BB) RS-/ Processor 0 Modem Buffer SUBASSEMBLY * 56 SUBASSEMBLY * PORT RTS PORT D PORT RTS PORT D PORT GND 0 PORT D 8 PORT CTS 6 PORT RTS PORT D COMPONENT SIDE OF BOARD SUBASSEMBLY * SUBASSEMBLY * - TO -56 VDC PORT GND PORT D PORT CTS GROUND PORT GND PORT D PORT CTS PORT RTS PORT D PORT GND PORT D PORT CTS CIRCUIT SIDE OF BOARD Fig. - MUX Interfaces TL s to a D-MAS-6070-V June 996

3 TL MUX Shipping List TL Network Elements Verify the following items were included in the shipment: TL - MUX Fuses -.5 Amp (/8 Amp) Registration Card TL - MUX Operation Guide To OSS Installation TL MUX Unpack the MUX and all accessories. (Do not plug MUX card into shelf yet.) Fill out and mail the pre-posted registration card. Mount the 00 shelf housing (separate item) in the Rack. Connect power wires to barrier terminals on back of shelf. (Refer to shelf documentation for terminal locations.) Connect communications lines to connectors on back of shelf. (See shelf documentation for connector locations.) Module connector pin-outs are shown in Fig.. Set DIP switches for data rates (see fig. 5 and Table B). If not factory installed, install comm. subassembly. Set jumpers on subassembly (see Fig. 5). Verify that power is correct for the option. See Options and Model Number section at the end of this Operation Guide. Plug MUX card into shelf. Insert fuse in appropriate slot in shelf fuse module. NOTE: Always remove fuse before removing or inserting MUX card. Proceed with testing per shelf Operation Guide. TL Network Elements RS TL MUX TL Network Elements RS Fig. - Cascade Multiple TL -port MUX s to Increase Capacity and SWT Buttons PAD IN PAD OUT RS 85: Both Closed RS : J Closed, J Open 0 EM TL -PORT MUX DIP SWITCH LOCATIONS J UP=OFF/DOWN=ON RS/85 J6 J Communications Subassembly Area XMT LVL MUX SW -8 Not Used J6 TEST J Front Panel J LEDS Terminate Shunt to Terminate J Open J Closed RS J J SW SW LEDS Fig. 5 - Communications Subassemblies Interface the MUX (), DIP Switches Set Baud D-MAS-6070-V June 996 OG0866

4 The LED display shows DIP switch status when the SWT button pressed and held. Test the LED display by pressing both the SWT and buttons at the same time. The Button by itself has no function. LED Display Status Refer to Fig. 6 and Table A for front panel LED functions. Table A - TL - MUX LED Display Functions LED Function - - TO - TO ER - ER TOM ERM XMT DATA RCV DATA DIP Switches Flashing indicates data being transmitted on port. Flashing indicates data being received on port. Flashing indicates time out on respective port. (A new message arrived, but time expired before the ; was received - usually indicates noise) Flashing indicates error on respective port. (Overflow, parity error or wrap-around to beginning of buffer.) This LED has no meaning. Flashing indicates error on MUX (common) port. (Overflow, parity error or wrap-around to beginning of buffer.) E - Future usage, has no meaning at present. Flashing indicates data being transmitted on MUX (common) port. Flashing indicates data being received on MUX (common) port. Refer to Fig. 5 and Table B for DIP switch functions. Table B - DIP Switch Functions MUX * Baud SW- SW- 00 OFF OFF 00 ON OFF 9600 OFF ON 9,00 ON ON Baud SW- SW- 00 ON OFF 00 OFF ON Baud SW- SW- 00 ON OFF 00 OFF ON Baud SW-5 SW-6 00 ON OFF 00 OFF ON Baud SW-7 SW-8 DPS INC "Your Partners in Telemetry Monitoring Systems" Press and SWT to test LED's No Function MUX Transmit MUX Receive 00 ON OFF 00 OFF ON *SW- through SW-8 have no function. **Incoming data is ignored. Transmit function is muted. Specifications D-6070 TLPORTMUX XMT DATA RCV DATA TO ER TO ER TO ER TO ER TOM ERM SWT Dimensions:.75" W. X 5.6" H. X 5.5" D. Mounting: 00-Type or Type 0 Telecom Shelf Input Voltage: -8 to -6, -6 to -7 or -8 to -7 VDC Input Current: 0 nom. 8 VDC, (5. W) 0 nom. VDC (5. W) Fuse value:.5 Amp (/8 Amp) Heat Dissipation: 8 nom. 8 VDC, 8 nom. VDC Interfaces: RS, RS, RS 85 Modems: T0 Protocol: TL Operating Temp.: 0 degrees to +60 degrees C. Humidity: 0% to 95% non-condensing Shipping weight: 8 oz. All specifications are subject to change without notice. Options & Model Numbers - Transmit and Receive - Time Out and Error MUX Time Out and Error Press to Show DIP Switch Settings Fig. 6 - Front Panel LED s Indicate MUX Status 955 E. Yale -Fresno, CA 977 -Phone: (559) /(800) 6- -FAX: (559) D-MAS-6070-V June 996

5 D-MAS-6070-V V = Voltage: 0 = -8 to -7 VDC TL - MUX = -8 to -6 VDC = -6 to -7 VDC Subassemblies D-MAS : 0 Modem (00 Baud) D-MAS-90-00: RS D-MAS-90-00: RS /RS 85 D-MAS-6070-V 5 OG0866 June 996

DPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda

DPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda DPS INC Operation Guide "Your Partners in Telemetry Monitoring Systems" ASCII MUX Fig. - ASCII MUX Expands T/MonXM ASCII s up to Eight Times Table Of Contents Overview... Functional Schematic... Typical

More information

DPS Telecom Your Partners in Telecom Management Networks

DPS Telecom Your Partners in Telecom Management Networks DPS Telecom Your Partners in Telecom Management Networks Operation Guide LR24 Relay Card Table of Contents Overview...1 Table of Contents...1 Typical Relay Applications...2 Shipping List....2 Installation...2

More information

Alarm Distribution Shelf (ADS)

Alarm Distribution Shelf (ADS) DPS Telecom Operation Guide "Your Partners In Telecom Management Networks" Alarm Distribution Shelf (ADS) Overview The ADS permits building and facility owners to collect and distribute alarms to their

More information

B Polling Interface

B Polling Interface Your Partners in Network Alarm Management 232-485B Polling Interface USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. July 31, 2006 D-OC-UM067.31100 Firmware Version

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual PCMNET V 7. xx INTEGRATED SYSTEMS AND CONTROLS, INC. PCMNET Users Manual Revised 2/4/2005 2003-2005 Integrated Systems and Control. Inc. PO Box

More information

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX Page 1 of 6 Model 104445A January 2014 ACCURATE ELECTRONICS INC PO BOX 1654 97075-1654 8687 SW HALL BLVD 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 WWW.ACCURATE.ORG Practice Section 104445A Rev

More information

Mini4 Dual Sonar Interface Board (P/N xxx) User s Manual And Troubleshooting Guide

Mini4 Dual Sonar Interface Board (P/N xxx) User s Manual And Troubleshooting Guide Mini4 Dual Sonar Interface Board (P/N 201630-xxx) User s Manual And Troubleshooting Guide February 23, 2009 Rev B Moog Components Group Springfield Operations 750 West Sproul Road Springfield, PA 19064

More information

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE 13050201 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN502 PRODUCT OVERVIEW 1 DN502 INSTALLATION 1 POWER

More information

Intelligent Devices IDI 1100 Series Technical Manual

Intelligent Devices IDI 1100 Series Technical Manual Intelligent Devices IDI 1100 Series 4411 Suwanee Dam Road, Suite 510 Suwanee, GA 30024 T: (770) 831-3370 support@intelligentdevicesinc.com Copyright 2011, Intelligent Devices, Inc. All Rights Reserved

More information

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 MODEL DSU-56 56 Kbps Rack Mount CSU/DSU OPERATOR S MANUAL 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 TEL: 775-345-8000 FAX: 775-345-8010 E-MAIL: SUPPORT @S.NET DSU-56 Rack Mount TABLE OF CONTENTS

More information

T1K MODBUS Base Controller Specifications

T1K MODBUS Base Controller Specifications Base Controller 1 2 In This Chapter.... Base Controller Setting the DIP Switches Setting the Rotary Address Switches Port Pin out and Wiring RJ12 Serial Port Pin out and Wiring 2 2 Base Controller General

More information

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP MAY 1997 ME745A-F-R2 ME745A-M-R2 ( Driver MP with 5-Screw Terminal Block) MINI DRIVER MP CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX

More information

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ. ME778C-RJ45 Line: RJ-45 MAIN MODULE Mini Driver MP Card ME778C-RJ45 Power Line: RJ-45 Unit A -TD -RD -CD -TD Serial: 10-Pin RJ INTERFACE MODULE (REAR CARD) Unit B -RD -CD Serial: 10-Pin RJ LO Z A HI Z

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE 13050301 (c) Copyright DIP Inc., 1996 DIP Inc. P.O. Box 9550 MORENO VALLEY, CA 92303 714-924-1730 CONTENTS DN503 PRODUCT OVERVIEW 1 DN503 INSTALLATION 1 POWER

More information

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free Instruction Manual Model 1582-45L Data Switch September 2010, Rev A REMOTE LOCAL SWITCH STATUS SELECT REMOTE LOCAL LOCAL SELECT CHANNEL SELECT POWER MODEL 1582 SWITCH CROSS TECHNOLOGIES, INC. Data, drawings,

More information

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. Getting Started This is a brief document designed to quickly get you started setting up your 2002 Series valve manifold with integrated Numatics G2-1\2 Profibus-DP communication protocol. Please note that

More information

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration

Table 8 shows the pin configuration and function of a standard computer-to-printer parallel cable. Table 8 Parallel Cable Pin Configuration Advanced Printer Inion Parallel Data Port Parallel Data Port The parallel data interface supports IEEE 1 bidirectional parallel communications in nibble mode. The parallel interface provides a means of

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1 TABLE OF CONTENTS TABLE OF CONTENTS... 1 IMPORTANT NOTICE... 2 PRODUCT CONFORMITY... 3 WARRANTY AND SAFETY INSTRUCTIONS... 4 1 GENERAL... 5 1.1 SATEL I-LINK 100 MODBUS I/O- CONVERTER... 5 2 SPECIFICATIONS...

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

ICP PANEL-TEC PEX3000 II

ICP PANEL-TEC PEX3000 II ICP PANEL-TEC PEX3000 II MODBUS PORT EXPANDER INSTALLATION AND OPERATION GUIDE REVISION HISTORY Revision Date Author Comments 000 29 Aug 2008 Keira Majors Initial release. 001 16 Sep 2008 David Walker

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

Installation and Operation Guide. KMD 5559 CommTalk

Installation and Operation Guide. KMD 5559 CommTalk Installation and Operation Guide Contents KMD 5559 CommTalk Description...3 Models...3 Specifications...3 Accessories...4 Mounting...5 Connecting the KMD 5559...5 Connecting power...9 Operation...9 Using

More information

Moxa TCC-100 Series User s Guide

Moxa TCC-100 Series User s Guide Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The

More information

ASTAT XB/XBm Remote Operator

ASTAT XB/XBm Remote Operator ASTAT XB/XBm Remote Operator User Manual 1 Introduction 1.1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery

More information

CS485. User s Manual. Version ZYPEX, Inc.

CS485. User s Manual. Version ZYPEX, Inc. CS485 User s Manual Version 2.0 2003 ZYPEX, Inc. Table of Contents Product Description 1 CS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter

More information

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...

More information

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed The Multi-I/O expansion board gives users the ability to add analog inputs and outputs, UART capability (for GPS or modem) and isolated high current outputs to the Flashlite 386Ex. Available in several

More information

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. Getting Started This is a brief document designed to quickly get you started setting up your 200/2012 Series valve manifold with integrated Numatics G2-2 Profibus-DP communication protocol. Please note

More information

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company Data Sheet SRM-6A Short-Range Asynchronous Modem The Access Company Features Asynchronous, full-duplex modem Data rates of up to 19.2 kbps SRM-6A transmission range of up to 8 km (5.0 mi) (for 24 AWG)

More information

6 Channel RS-422 Board (P/N xxx) User s Manual. And. Troubleshooting Guide

6 Channel RS-422 Board (P/N xxx) User s Manual. And. Troubleshooting Guide 6 Channel RS-422 Board (P/N 200560-xxx) User s Manual And Troubleshooting Guide February 24, 2009 Rev. B Moog Components Group Springfield Operations 750 West Sproul Road Springfield, PA 19064 E-Mail:

More information

General LCD Display (GLD)

General LCD Display (GLD) DPS Telecom Your Partners in Network Alarm Monitoring General LCD Display (GLD) USER MANUAL Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs. June 2, 2010 D-OC-UM106.02100 Version

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

Converter Box Data Sheet

Converter Box Data Sheet Page 1 from 6 Functions of the converter box The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to

More information

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual. MODBUS supplementary manual to the 2300-A8VI Installation Guide. The 2300 series stations are designed to

More information

Mini4 Data Mux User s Manual. ( xxx) And. Troubleshooting Guide

Mini4 Data Mux User s Manual. ( xxx) And. Troubleshooting Guide Mini4 Data Mux User s Manual And Troubleshooting Guide June 7, 2010 Rev B Moog Components Group 750 West Sproul Road, Springfield, PA 19064 E-Mail: URL: Tel: 610-328-4000 Fax: TABLE OF CONTENTS 1 Mini4

More information

Redundant Master Controller Installation Instructions

Redundant Master Controller Installation Instructions Redundant Master Controller Installation Instructions Introduction This publication describes the installation procedure for the 4100-9121, 4100-9122, and 4100-9222 redundant master controller panels.

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

ANC Series RS-422 Serial Communications Adapter

ANC Series RS-422 Serial Communications Adapter Rev. B $ 5.00 ANC - 6000 Series RS-422 Serial Communications Adapter Antona Corporation, Los Angeles, CA Antona Corporation (818)783-4299 FAX (818)783-4216 1 Antona Corporation Copyright Copyright (c)

More information

Enhanced Mini-Chansim Model VCS-232

Enhanced Mini-Chansim Model VCS-232 Enhanced Mini-Chansim Model VCS-232 Operations Manual ViaSat Inc. 6155 El Camino Real Carlsbad, CA 92009 http://www.viasat.com SAFETY WARNING Always observe standard safety precautions during installation,

More information

Moog Components Group Submux1 Manual December 7, 2009

Moog Components Group Submux1 Manual December 7, 2009 RS-232 Submux Motherboard (P/N 970381-xxx) and Daughter-cards (4 ch. RS-232 P/N 970391-xxx, 4ch. RS-485 / 2 ch. RS422 P/N 980430-xxx, and Trigger Interface P/N 200700-XXX) User s Manual And Troubleshooting

More information

Conitel ASYNC Adapter

Conitel ASYNC Adapter Conitel ASYNC Adapter TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS... SECTION - INSTALLATION...6 SECTION - CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...11

More information

Table 1 Specifications Software Required for Configuration

Table 1 Specifications Software Required for Configuration PROFIBUS SLAVE Products Specifications and Installation Data The following information is taken from the Profibus Slave User Manual (MAN0002). To obtain user manual updates for HE693PBS105, visit our web

More information

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD

BOARD LEVEL PRODUCTS GPIB<->RS-422/RS-485 INTERFACE BOARD BOARD LEVEL PRODUCTS RS-422/ INTERFACE BOARD DESCRIPTION The Model Serial Interface is a small, low cost interface board that interfaces serial devices with RS-422 or signals to the bus. The provides

More information

Revision Change / Release Number Signature / Date

Revision Change / Release Number Signature / Date Title: E84 SPC Controller Hardware Technical Reference Manual Name / Title Signature / Date Originator: Andrew Giusti / Software Engineering Manager Andrew Giusti / 4-13-07 Check: Joel Ronning / President

More information

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card EX-45362 & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card Congratulation on your purchasing this high performance 2-Port RS232/422/485 3-in-1 Serial PCIe Host Adapter. The adapter is high speed PCIe

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp. C-Programmable Controller P00 Series The P00 Series of C-programmable controllers is based on the Zilog Z80 microprocessor. The P00 includes digital, serial, and high-current switching interfaces. The

More information

Audio Input Card Installation Instructions

Audio Input Card Installation Instructions Installation Instructions Introduction This publication describes the installation procedure for the 4100-1240. This card is compatible with 4100U and 4100ES Fire Alarm Control Panels. In this Publication

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Type-5500 with Profibus-DP Interface Quick Start Manual

Type-5500 with Profibus-DP Interface Quick Start Manual Getting Started This is a brief document designed to quickly get you started setting up your Type-5500 manifold with integrated Profibus-DP communication protocol. Please note that this document is not

More information

M-Bus Central Unit. Use

M-Bus Central Unit. Use 6 M-Bus Central Unit OZW The M-bus central unit is used for the remote readout, remote operation and supervision of an M-bus plant with a maximum of consumption meters and controllers featuring an M-bus

More information

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,

More information

ISDN OEM1. DesignGuide V1.2

ISDN OEM1. DesignGuide V1.2 ISDN OEM1 DesignGuide V1.2 Content ISDN OEM1...1 1 Objective...3 2 Product description...3 3 Software interfaces...4 3.1 Dialing procedures...4 3.2 AT commands...4 3.2.1 Configuration commands...4 3.2.2

More information

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

RS-232 to RS-422/485 Converter with 3KV Isolation Protection RS-232 to RS-422/485 Converter with 3KV Isolation Protection (ID-SC0E11-S1) User s Manual 04-0779A - 1 - Introduction The serial converter converts RS 232 signals to RS 422 or RS 485 and extends the communication

More information

rdczbk User Manual ZigBee to RS-232 / RS-485 Converter

rdczbk User Manual ZigBee to RS-232 / RS-485 Converter 1. Product Overview rdczbk User Manual ZigBee to RS-232 / RS-485 Converter Robust DataComm Pte Ltd The rdczbk is basically a XBee / XBee Pro carrier board that provides either RS-485 or RS-232 connectivity

More information

Breadboard & Digital Input/Output Modules

Breadboard & Digital Input/Output Modules USER MANUAL Model No. 20-210 20-410 Breadboard & Digital Input/Output Modules Note: 20-210 has been upgraded to 20-210A with ZIF front panel connectors replacing Elco types. All other functionality is

More information

NM-251D-INC. Dual Axis Inclinometer Output Format converter User Guide V1.00. Introduction

NM-251D-INC. Dual Axis Inclinometer Output Format converter User Guide V1.00. Introduction NM-251D-INC Dual Axis Inclinometer Output Format converter User Guide V1.00 Introduction The NM-251D-INC is a member of the NM- 251 Series family and is programmed to function as an Inclinometer Sensor

More information

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem ZM56 High-Speed Industrial Modem Command Summary 1 ZM56 High-Speed Industrial Modem AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands

More information

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL REVISED: 8/12/13 DGH CORPORATION PO BOX 5638 MANCHESTER, NH 03108 TELEPHONE: 603-622-0452 FAX: 603-622-0487 WEB: www.dghcorp.com The information

More information

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison DNETEXT-C CAN Bus Extender, Version 3 User s Manual Brad Harrison Although every effort has been made to insure the accuracy of this document, all information is subject to change without notice. Woodhead

More information

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION

USER S MANUAL SI-700 SI EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 FOUNDATION USER S MANUAL SI-700 SI-700 - EIA-232/ EIA-485 INTERFACE JUL / 05 SI-700 VERSION 1 TM FOUNDATION S I 7 0 0 M E smar www.smar.com Specifications and information are subject to change without notice. Up-to-date

More information

3.1 I-7560 Pin Assignment and Specifications: Introduction

3.1 I-7560 Pin Assignment and Specifications: Introduction 3.1 I-7560 Pin Assignment and Specifications: Introduction The I-7560 adds a Windows serial Com port via its USB connection and is compatible with new & legacy RS-232 devices. USB Plug and Play allows

More information

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN. ME930C-RJ11 Line: RJ-11 ME930C-RJ11 MAIN MODULE Power -TD -RD INTERFACE MODULE (REAR CARD) TEST -Cntrl In -Cntrl Out Serial: DB25 CN. 7 8 SW1 JB2 1 2 3 RJ-11 CN. JB3 INTERFACE MODULE (REAR CARD) 1 2 3

More information

DPM-3221 Digital DC Power Meter with data logging capability.

DPM-3221 Digital DC Power Meter with data logging capability. Introduction DPM-3221 Digital DC Power Meter with data logging capability. User Manual As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-200 A with the correct shunt),

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

Revision: 5/7/ E Main Suite D Pullman, WA (509) Voice and Fax. Power jack 5-9VDC. Serial Port. Parallel Port

Revision: 5/7/ E Main Suite D Pullman, WA (509) Voice and Fax. Power jack 5-9VDC. Serial Port. Parallel Port Digilent Digilab 2 Reference Manual www.digilentinc.com Revision: 5/7/02 215 E Main Suite D Pullman, WA 99163 (509) 334 6306 Voice and Fax Overview The Digilab 2 development board (the D2) features the

More information

SD-50 Vehicle Dock. Introduction. Highlights. Ordering

SD-50 Vehicle Dock. Introduction. Highlights. Ordering Vehicle Dock Quick Specification Loud Speaker Dock for Intermec CN50 Front View Back View Introduction The SD-50 vehicle dock provides a simple method to produce outstanding audio from Intermec s CN50

More information

Serial Interface Module

Serial Interface Module OnQ 363737-01 Serial Interface Module DESCRIPTION The 363737-01 Serial Interface can be used with Model 925 or Model 1050 controller. It allows the controller to be connected to a personal computer or

More information

Digilab 2E Reference Manual

Digilab 2E Reference Manual Digilent 2E System Board Reference Manual www.digilentinc.com Revision: February 8, 2005 246 East Main Pullman, WA 99163 (509) 334 6306 Voice and Fax Digilab 2E Reference Manual Overview The Digilab 2E

More information

QuickSilver Controls, Inc. Datasheet: QCI-DS030. SilverMax 23 Frame X-Series

QuickSilver Controls, Inc. Datasheet: QCI-DS030. SilverMax 23 Frame X-Series Datasheet: QCI-DS3 Date: 7 June 216 www.quicksilvercontrols.com SilverMax 23 Frame X-Series The SilverMax is a fully integrated Hybrid Servo Motor with feedback, a Controller/Indexer, and a Digital Driver

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual Vorne Industries 2000S Series Serial Input Alphanumeric Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 Telephone (630) 875-3600 Telefax (630) 875-3609 2000S Series Serial Input Alphanumeric

More information

Connecting a Cisco Input Module

Connecting a Cisco Input Module CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each

More information

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. Quick Start Manual Getting Started This is a brief document designed to quickly get you started setting up your 2004 Series valve manifold with integrated Numatics G2- A-B 77 Remote I/O communication protocol.

More information

Controller Extension Box

Controller Extension Box Controller Extension Box USER MANUAL Visit our website at www.dpstele.com for the latest PDF manual and FAQs. November 18, 2015 D-UM-CTLEX Revision History November 18, 2015 Specs update November 21, 2012

More information

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,

More information

MM2/Mini4 10/100 Ethernet Daughterboard (P/N xxx) User s Manual And Troubleshooting Guide

MM2/Mini4 10/100 Ethernet Daughterboard (P/N xxx) User s Manual And Troubleshooting Guide MM2/Mini4 10/100 Ethernet Daughterboard (P/N 201750-xxx) User s Manual And Troubleshooting Guide February 24, 2009 Revision B Moog Components Group Springfield Operations 750 West Sproul Road Springfield,

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

is then retained absolutely without interruption.

is then retained absolutely without interruption. Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately

More information

Environdata FA ma Converter Guide

Environdata FA ma Converter Guide FA12 4 20 ma Converter Guide REV 14 th July 2015 Material in this Handbook is copyright. All rights reserved by the publishers. Weather Stations Pty. Ltd., 42-44 Percy Street, Warwick, Queensland, AUSTRALIA,

More information

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters USER MANUAL MODEL 2017P RS-232 to 20mA and MODEL 2017P60 RS-232 to 60mA Current Loop Converters 07M2017P-E Doc# 073051UE Revised 5/7/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0

More information

Installation & Operation Guide

Installation & Operation Guide Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

KeyVerter. PS/2 Keyboard To RS-232/TTL Converter. Copyright 2003 Intuitive Circuits, LLC

KeyVerter. PS/2 Keyboard To RS-232/TTL Converter. Copyright 2003 Intuitive Circuits, LLC KeyVerter PS/2 Keyboard To RS-232/TTL Converter Copyright 2003 Intuitive Circuits, LLC D escription KeyVerter converts key stroke events from any PS/2 keyboard (small DIN connector) into an RS-232 and

More information

CTI CALL INFORMATION INTERFACE

CTI CALL INFORMATION INTERFACE CTI CALL INFORMATION INTERFACE MODEL CN-4750 SERIAL/ITEM 533/nnn OPERATOR MANUAL Issue 3, FEB, 2002 AUTHOR: PETER ZEUG PATENTS PENDING DESIGNED AND MANUFACTURED IN AUSTRALIA DESIGN TWO THOUSAND PTY LTD

More information

TRAKIT-25P. Printings. Version 1.00: 10/03/01 Version 2.00: 01/20/03 Version 2.10: 01/19/04

TRAKIT-25P. Printings. Version 1.00: 10/03/01 Version 2.00: 01/20/03 Version 2.10: 01/19/04 TRAKIT-25P Printings Version 1.00: 10/03/01 Version 2.00: 01/20/03 Version 2.10: 01/19/04 TABLE OF CONTENTS SPECIFICATIONS... 1 1.0 GENERAL DESCRIPTION... 2 1.1 Description... 2 1.2 Capabilities and Features...

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

H3G-48B Production Description

H3G-48B Production Description H3G-48B Production Description Designed for communication battery strings of 24 batteries each of VRLA and Ni-Cd battery 1 Applications For strings of 24 batteries each Base Station (2V X 24 batteries)

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MicroComm DXI. Intent & Scope This document describes the installation procedure for the IMS-30 Intercom Master Station and the MAI-420 or MAI-20 Master Audio Interface. The earliest

More information

and Network Interface Modules Installation Instructions

and Network Interface Modules Installation Instructions 4010-9817 and 4010-9821 Network Interface Modules Installation Instructions Cautions and Warnings DO NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED. Upon unpacking your Simplex product, inspect the

More information

DSP Filter System. Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, Doc Number: AIGO-009

DSP Filter System. Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, Doc Number: AIGO-009 DSP Filter System Author: Nels Pearson Org Date: July 5, 2007 Rev Date: July 6, 2007 Doc Number: AIGO-009 2-13 Table of Contents Introduction...3 Overview...3 A2D Input Filter Board...4 Overview...4 Input

More information