SOLAR ORBITER ENERGETIC PARTICLE DETECTOR
|
|
- Baldric Moore
- 5 years ago
- Views:
Transcription
1 Page: 1 of 19 SOLAR ORBITER ENERGETIC PARTICLE DETECTOR EPT-HET-2 FM Physical Document ID: SO-EPD-KIE-TP-0030 Issue: 1 Revision: 0 Date: 15/02/2016 Signature not needed if electronically approved by route Written Checked Approved Configuration Control Approved QA Approved Experiment Manager Approved Principal Investigator Walter Boogaerts Lars Seimetz César Martín Walter Boogaerts Mike Richards Ali Ravanbakhsh César Martín Robert Wimmer File: SO-EPD-KIE-TP-0031_iss1_rev0_EPT- HET2_FM_physical_properties_test_procedure..docx Pages: 19
2 Page: 2 of 19 DISTRIBUTION LIST The following lists indicate the individuals and agencies in receipt of review copies of the present document: Agency / Organization Name & Title Contact information Javier Rodríguez-Pacheco SRG-UAH EPD Principal Investigator javier.pacheco@uah.es SRG-UAH SRG-UAH SRG-UAH SENER SENER CAU CAU Manuel Prieto EPD Project Manager Cecilia Gordillo EPD Configuration Control Responsible Andrés Russu Berlanga EPD AIVT Responsible Maria Teresa Gomez Calzado EPD System Engineer Jarabo Lopez, Santiago EPD Product Assurance Manager Michael Richards EPD/Kiel Product Assurance Manager Walter Boogaerts EPD/Kiel Product Assurance Manager manuel.prieto@uah.es cecilia.gordillo@uah.es andres.russu@uah.es maite.gomez@sener.es santiago.jarabo@sener.es mlr@richards-consulting.eu WBoogaerts@gmx.net CAU EPD Kiel Team solo_kiel@physik.uni-kiel.de
3 Page: 3 of 19 CHANGES RECORD Issue Revision Date Modified by Section / Paragraph modified Change implemented /2/2016 All Initial release
4 Page: 4 of 19 TABLE OF CONTENTS 1 INTRODUCTION Purpose Scope GLOSARY AND DEFINITIONS Acronyms APPLICABLE AND REFERENCE DOCUMENTS Applicable Documents Normative Documents Reference Documents TEST OVERVIEW Test objectives Test facility Test Equipment Environmental conditions Test documentation Participants Safety and ESD Item under test TEST PARAMETERS Test requirements Test tolerances Pass/fail criteria TEST Visual Inspection Mechanical Interface Measurements CONNECTOR / STUD / HARNESS Locations Harness OVERVIEW TESTING Deviations Pass / Fail Overview List of tables Table 2-I Table of Acronyms... 7 Table 3-I Table of Applicable Documents... 8 Table 3-II Table of Reference Documents... 8 Table 4-I Table of Test-Equipment... 9 Table 6-I Visual Inspection Table 6-II Mechanical I/F-Check Table 6-III Mass-Properties... 16
5 Page: 5 of 19 Table 6-V CoG and MoI Table 7-I Connector / STUD Table 8-I List of test deviations Table 8-II Pass / Fail Overview List of Figures Figure 1 Current CAD drawing of EPT-HET unit Figure 2 Mechanical Overview EPT-HET... 14
6 Page: 6 of 19 1 INTRODUCTION 1.1 Purpose The aim of this document is to define the foreseen plan in order to verify physical properties of EPT- HET-1 FM according to AD03 Chapter Physical properties Measurements, AD01 Requirements and the ESA-Requirement EIDA R-023: which will be specified in this Procedure. The requirements will be added to each specification. 1.2 Scope This document applies to all activities related to EPT-HET FM properties verification campaign performed by all institutions and personnel involved in the test. The Test Report will be the contents of this procedure added by the results and pictures of the measurements.
7 Page: 7 of 19 2 GLOSARY AND DEFINITIONS 2.1 Acronyms Table 2-I Table of Acronyms CAU CoG EIDA EPD EPT FM HET Christian-Albrechts-Universität zu Kiel Center of Gravity Experiment Interface Document-Part A Energetic Particles Detector Electron, Proton Telescope Flight Model High Energy Telescope MICD Mechanical Interface Controlled Document MoI N/A tbd tbi PA RH S/C Moment of Inertia Not Applicable to be decided to be issued Product Assurance Reference Hole Space Craft STUD Grounding Point of Instrument URP URF Unit Reference Point Unit Physical Reference Frame
8 Page: 8 of 19 3 APPLICABLE AND REFERENCE DOCUMENTS 3.1 Applicable Documents Table 3-I Table of Applicable Documents ID. Title Reference Iss./Rev. Date AD-01 Experiment Interface Document part A SOL-EST-RCD /0 16/03/2015 AD-02 EPT-HET and STEP Assembly, Integration and Test Plan SO-EPD-KIE-PL /0 03/05/2013 AD-03 Space Engineering : Testing ECSS-E C 01/06/2012 AD-04 EPT-HET Vibration Report FM tbi AD-05 SO-EPD-KIE-RD-0001 RfD_for_mass_properties 2/ Normative Documents ID. Title Reference Iss./Rev. Date ND-01 ND-02 Safety instructions for IEAP CAU facilities ESD Control Program for the SO/EPD-Project at CAU SO-EPD-KIE-TP /0 30/11/ Reference Documents Table 3-II Table of Reference Documents ID. Title Reference Iss./Rev. Date SO-EPD-KIE-DR-0001 RD-01 EPT-HET MICD (EPD_EPTHET_ _5-4_SO-EPD-KIE-DR- 0001_fm_micd.zip) 5/ RD-02 Harness Specification SO-EPD-SEN-RS /
9 Page: 9 of 19 4 TEST OVERVIEW 4.1 Test objectives The objective of this Procedure to Physical Properties to prove the requirements from AD01 / AD03 and the values of RD Test facility Test Facility for Physical properties is tbd. 4.3 Test Equipment Table 4-I Table of Test-Equipment Nr Instr. / Equipment Description Manufacturer Model/Type-Nr. Inv. Nr. Calibration Last Next 4.4 Environmental conditions Temperature*: C Relative humidity % Cleanliness: ISO 8 * Environmental condition to be recorded as-run test performance. 4.5 Test documentation A completed test report will be presented after the test. Discussion will conclude the success/failure of the mass properties verification process.
10 Page: 10 of Participants The test participants and their responsibilities are defined in Table Table Test participants and their responsibilities. CAU # Name Responsibility Safety and ESD CAU facility general safety requirements shall apply during all operations [ND-01]. ESD Precautions acc. to ND Item under test As seen in Figure 1, the EPT and HET sensor heads share a common Ebox. For the Properties test, EPT-HET FM will not be covered by MLI.
11 Page: 11 of 19 Figure 1 Current CAD drawing of EPT-HET unit..
12 Page: 12 of 19 5 TEST PARAMETERS 5.1 Test requirements EIDA R-050: The PI shall ensure that the difference between the measured mass of each STM unit and FM unit with the respective nominal mass, specified in the relevant MICD, current at the time of the STM and FM delivery, is less than 1%. 5.2 Test tolerances EIDA R-440: The PI shall respect the following test tolerances, unless otherwise specified. The test level tolerances are acc. to EIDA R-440 and the several Requirements mentioned in the Overview. 5.3 Pass/fail criteria For an Overview of the test pass/fail criteria, including their tolerance, see Tables 8-I / 8-II
13 Page: 13 of 19 6 TEST 6.1 Visual Inspection Table 6-I Visual Inspection Identification Label Instrument Label EPD/EH2 Thermal Finish Acc. to RD-01: Housing/Baseplate: Iridite 14.2 Connector Savers Are used where more than 50 Mating/Demating cycles would degrade permanently the mounted connector Protective Covers Conductive Covers on unmated Connectors Red Tag Items Acc. to RD-01: for EPTHET and STEP. Cleanliness Class ISO 8 Safety devices Handling Provisions 3x S/C - Thermistors Transport Container Purging Connections General Appearance To be handled by hand with ESD protected gloves in class ISO 8 acc. to ND-02. Handling and Restricted Areas specified in RD-01. See Instrument Locations for Handling in RD-01 Acc. to RD-01: close to URP (See remark: Survival Heaters on this face) Under manufacture Acc. to RD-01: Purging Inlet OK / not OK Label for Connector Stud / Ref. EID-A Requirements R-002 Unit/Stud/etc. R-003 Connectors/Harness R-004 Connectors R-062 (Contact Surfaces free of Paint!) R-108 R-716 Removal Procedure to prepare (tbd). EIDA-1662 EIDA-3260 EIDA R-330 Handling,etc. Procedure to prepare (tbd). R-107 R-741 Transport: EIDA-3256 R-329 Purging: R-688 Ch Purging
14 Page: 14 of Mechanical Interface Measurements Mechanical Overview EPT-HET Figure 2 Mechanical Overview EPT-HET
15 Page: 15 of Mechanical I/F Check The Parts are internally tracked by manufacturing flow charts and incoming inspections. Table 6-II Mechanical I/F-Check Step Specification Actual EID-A Requirements Envelope Dimensions: Y MLI additional X Z Mounting Hole Position: Xu Yu Xu Yu R-023 for URF URF: mm Mounting Hole URF: R-067 Diameter : R / -0.0 mm Spot Face Areas : : URF R Mount. Feet Thickness: URF: mm 3 mm 3 mm 3 mm R-069
16 Page: 16 of 19 Mounting Feet URF : Contact Area Acc. to RD-01: Approx.. 70 mm 2 (x4) R-769 Effective Contact area to S/C- Interface surface approx. 350 mm 2 (M5) Isolation Bushes Surface Flatness Surface Roughness of Contact Area 4x Thermal Stand Off s and Thermal Washers mounting surface flatness < +/ mm per 100 mm length R-770 mounting feet surface roughness Rz ~ 6.4 (Only Load Carrying Functions) Mass Properties Table 6-III Mass-Properties Mass acc. to Reference Measured Remarks MICD (RD01) Mass will be measured as a whole without breakdown. MLI and MLI Standoffs not implemented Feet Standoffs not glue
17 Page: 17 of CoG and MoI Table 6-IV CoG and MoI FM FM Drawings Predicted Measured CoG X mm acc. to (wrt URF) Z 70.5 mm RD01 MoI I xx I zz Y mm Will not be measured acc. to kgmm kgmm 2 RD I yy kgmm 2
18 Page: 18 of 19 7 CONNECTOR / STUD / HARNESS 7.1 Locations The Parts are internally tracked by manufacturing flow charts and incoming inspections. Table 7-I Connector / STUD Conn. Stud Specifications (URF) Actual (URF) Connector Fixation Remarks X Z Y X Z Y J29_S -79,94 20,0-119,3 Main Instrument (ICU) EPTHET 1 J40_S -8,2 33,82 14,23 TCS (S/C) J33_S -79,94 20,0-119,3 Main Instrument (ICU) EPTHET 2 J41_S -8,2 33,82 14,23 TCS (S/C) Stud -88,0 27,5 26,3 Z-included Isolation Bushes Purging Inlet 13,0 29,0-139,5 (see RD-01) 7.2 Harness See overview under RD02
19 Page: 19 of 19 8 OVERVIEW TESTING 8.1 Deviations Test deviations will be reported in the final approved as-run test procedure as part of the test documentation. Table 8-I List of test deviations. # Test deviation Comment Pass / Fail Overview Table 8-II Pass / Fail Overview # Reference Comment
SOLAR ORBITER ENERGETIC PARTICLE DETECTOR
Page: 1 of 19 SOLAR ORBITER ENERGETIC PARTICLE DETECTOR STEP FM Physical Properties Document ID: SO-EPD-KIE-TP-0033 Issue: 1 Revision: 0 Signature not needed if electronically approved by route Written
More informationEPT-HET FM Configuration Item Data List /As Built
Page: 1 de 19 EPT-HET FM Document ID: SO-EPD-KIE-LI-0011 Issue: 1 Revision: 0 Signature not needed if electronically approved by route Written Checked Approved Configuration Control Approved QA Approved
More informationDRAFT. Lunar Reconnaissance Orbiter (LRO) Component Mechanical Interface Control Drawing Guidelines Handbook
DRAFT Lunar Reconnaissance Orbiter (LRO) Component Mechanical Interface Control Drawing Guidelines Handbook 431-HDBK-000093 Expected Release Date: June 30, 2005 Expiration Date: December 31, 2010 Prepared
More information(PTP) Procedure for TRE Random Noise Data Collection
GRAVITY PROBE B PROCEDURE FOR PAYLOAD VERIFICATION (PTP) Procedure for TRE Random Noise Data Collection P0490 Rev. A Approvals: Prepared by: Bob Farley Program Responsibility Signature Date Bob Farley
More informationPower Distribution Unit (PDU) Specification - Level V Specification
Document # Date effective LAT-SS-06988-02 10/05/2005 Author(s) Supersedes Patrick Young Rev 01 Subsystem/Office Electronics & DAQ Subsystem Document Title Power Distribution Unit (PDU) Specification -
More information(PTP) TRE INSTALLATION INCLUDING CABLES
SU/GP-B P0541 Rev A STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 (PTP) TRE INSTALLATION INCLUDING CABLES
More informationProton Monitor Inrush Current Test Procedure GP-B P0638
Procedure Number P0638 Rev Page Count: 5 W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission Proton Monitor Inrush Current
More informationINTERNAL THALES ALENIA SPACE STANDARD : DATE : CHANGE RECORDS. Paragraphs Change Record (List of paragraphs modified, new or deleted)
ISSUE : 01 PAGE : 2/10 CHANGE RECORDS Paragraphs Change Record (List of paragraphs modified, new or deleted) Issue Date Change Record Description Author Draft 17/09/10 First preliminary issue 01 First
More informationSSPP-TEV-035 HITCHHIKER ADVANCED CARRIER EQUIPMENT RANDOM VIBRATION TEST PLAN BASIC RELEASE MARCH 1997 GODDARD SPACE FLIGHT CENTER GREENBELT, MARYLAND
HITCHHIKER ADVANCED CARRIER EQUIPMENT RANDOM VIBRATION TEST PLAN SSPP-TEV-035 BASIC RELEASE MARCH 1997 GODDARD SPACE FLIGHT CENTER GREENBELT, MARYLAND PREPARED BY: 5050 POWDER MILL ROAD BELTSVILLE, MD
More informationPOST-INTEGRATION CHECKOUT OF SUSPENSION CABLES
STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 POST-INTEGRATION CHECKOUT OF SUSPENSION CABLES -B SCIENCE
More informationLAT-TD /05/2005. PDU CCA Test Procedure. P. Young Rev. 01
Document # Date effective LAT-TD-02544-02 05/05/2005 Author(s) Supersedes P. Young Rev. 01 Document Title PDU CCA Test Procedure Subsystem/Office Electronics & DAQ Subsystem revision. CHANGE HISTORY LOG
More informationLAT-TD /22/2005. Power Distribution Unit Stray Voltage Test. Patrick Young Rev. 03 Brian Horwitz
Document # Date effective LAT-TD-04384-04 06/22/2005 Author(s) Supersedes Patrick Young Rev. 03 Brian Horwitz Subsystem/Office Electronics & DAQ Subsystem Document Title Power Distribution Unit Stray Voltage
More information(PTP) AFT GSS TEMPORARY INSTALLATION
SU/GP-B P0849 Rev - STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 (PTP) AFT GSS TEMPORARY INSTALLATION
More informationLAT-TD /28/2005. Power Distribution Unit Stray Voltage Test. Patrick Young Rev. 05 Brian Horwitz
Document # Date effective LAT-TD-04384-06 09/28/2005 Author(s) Supersedes Patrick Young Rev. 05 Brian Horwitz Subsystem/Office Electronics & DAQ Subsystem Document Title Power Distribution Unit Stray Voltage
More informationSTANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA
October 04, 2000 STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 GP-B SCIENCE MISSION DEWAR OPERATIONS ORDER
More informationCONNECT INPUT CABLE TO SQUID P0682 Rev -
1 STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 SU/GPB P0682 Rev - CONNECT INPUT CABLE TO SQUID P0682
More informationBOARD-LEVEL TEST PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM (GSS) FORWARD BACKPLANE (FBP) BOARD. GP-B Procedure P0601 Rev
P0601 Rev. May 10, 2000 W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission BOARD-LEVEL TEST PROCEDURE FOR THE GYROSCOPE
More informationHOOK-UP AND CHECK-OUT OF ALL GYRO CABLES WITH PROBE CONNECTORS
SU/GP-B P0431 Rev STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 HOOK-UP AND CHECK-OUT OF ALL GYRO CABLES
More informationCLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES
CLEANROOM CERTIFICATION AND ACCEPTANCE PROCEDURES PART I--GENERAL 1.1 Work Included [Edit this specification to eliminate tests not required. Place tests in the desired sequence of performance] A. This
More informationDRAFT. Robotic Lunar Exploration Program Lunar Reconnaissance Orbiter. June 23, Goddard Space Flight Center Greenbelt, Maryland
DRAFT Robotic Lunar Exploration Program Lunar Reconnaissance Orbiter Cosmic Ray Telescope for the Effects of Radiation (CRaTER) to Spacecraft Electrical Interface Control Document (ICD) June 23, 2005 Goddard
More informationPREPARE PROBE FOR CLASS 10 CLEANROOM
SU/GP-B P0409 Rev STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 PREPARE PROBE FOR CLASS 10 CLEANROOM GP-B
More informationTest Procedure for I8, I9 Probe Wiring Verification
September 9, 1998 W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission Test Procedure for I8, I9 Probe Wiring Verification
More informationFULL FUNCTIONAL TEST PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM (GSS) AFT SUSPENSION UNIT (ASU) SUBSYSTEM. GP-B Procedure.
ASU FF W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission FULL FUNCTIONAL TEST PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM
More informationGYROSCOPE SUSPENSION SYSTEM (GSS) FORWARD SUSPENSION UNIT (FSU) SUBSYSTEM LOW TEMP RELAY PERFORMANCE CHECK. P0751 Rev
W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission GYROSCOPE SUSPENSION SYSTEM (GSS) FORWARD SUSPENSION UNIT (FSU) SUBSYSTEM
More informationApproval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date
ATS-ATP-3405 Page: 1 of 8 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013
More informationINTERFACE CONTROL DOCUMENT
STUDENTS SPACE ASSOCIATION THE FACULTY OF POWER AND AERONAUTICAL ENGINEERING WARSAW UNIVERSITY OF TECHNOLOGY INTERFACE CONTROL DOCUMENT November 2016 Issue no. 2 (March 2017) Changes Date Changes Pages/Section
More informationElectrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)
225 Watt Industrial Features 4 x 2 x 1 Inches Form factor 225 Watts with Forced Air Cooling Efficiencies upto 94% -40 to 70 degree operating temperature* 12V / 0.5A Fan Output, Thermal Shut-Down feature
More informationEngineering Specifications for the X-Ray Focusing Lens System
ENGINEERING SPECIFICATION DOCUMENT (ESD) Doc. No. SP-391-000-58 R0 LUSI SUB-SYSTEM Diagnostics Engineering Specifications for the X-Ray Focusing Lens System Prepared by: Marc Campell Signature Date Design
More informationD-510 PISeca Single-Electrode Capacitive Sensor Probe
Technical Note BSc, BRo, D-510 PISeca Single-Electrode Capacitive Sensor Probe Fig. 1: D-510 Single-Electrode Capacitive Sensor probe with E-852.10 signal conditioner electronics The D-510 Single-Electrode
More informationComputer-Based Control System Safety Requirements
Computer-Based Control System Safety Requirements International Space Station Program Revision B November 17, 1995 National Aeronautics and Space Administration International Space Station Program Johnson
More informationEnvironmental Control and Monitoring (Draft)
Next Generation Adaptive Optics System Environmental Control and Monitoring (Draft) April 10, 2009 VersionV1.0 Prepared By Jason Chin 2 of 11 REVISION HISTORY Revision Date Author (s) Reason for revision
More informationCoda cx1 Long Form Functional Test Procedure
Coda cx1 Long Form Functional Test Procedure CDL 1-TP07-0500:0211 MIT Ref. 85-01050.02 Revision 2.0 28 th July 2004 CDL 1-TP07-0500:0211 Contents 1 Introduction... 1 1.1 Activity Description... 1 1.2 Test
More informationProduct Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications
Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications 10/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with
More informationzqsfp+stacked Connector and Cage Assembly
Product Specification 108-60102 May 27, 2015 Rev A1 zqsfp+stacked Connector and Cage Assembly 1. SCOPE 1.1. Content This specification defines performance, test and quality requirements for the zqsfp+stacked
More informationLAT PROJECT DOCUMENT CHANGE NOTICE (DCN) SHEET 1 OF 1
DCN No. LAT-XR-04681-01 LAT PROJECT DOCUMENT CHANGE NOTICE (DCN) SHEET 1 OF 1 ORIGINATOR: Dave Nelson PHONE: 650-926-4652 DATE: 10/29/04 CHANGE TITLE: DCN for TPS Validation Test Procedure ORG.: DOCUMENT
More informationCRITICAL DESIGN REVIEW
STUDENTS SPACE ASSOCIATION THE FACULTY OF POWER AND AERONAUTICAL ENGINEERING WARSAW UNIVERSITY OF TECHNOLOGY CRITICAL DESIGN REVIEW November 2016 Issue no. 1 Changes Date Changes Pages/Section Responsible
More informationON-BOARD A/D AND D/A CONVERTER CALIBRATION PROCEDURE FOR GSS FORWARD SUSPENSION UNITS (FSU) GP-B Procedure P0892 Rev -
W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission ON-BOARD A/D AND D/A CONVERTER CALIBRATION PROCEDURE FOR GSS FORWARD
More informationProduct Specification
Product Specification PR041-01 Revision A0 (Date 4-3-2017) Stewart Connector 11118 Susquehanna Trail South Glen Rock, Pa. 17327-9199 Ph: (717) 235-7512 Fax: (717) 235-4675 Product Specification PR0410-01
More informationFUNCTIONAL TEST PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM (GSS) AFT CONTROL UNIT (ACU) SUBSYSTEM. GP-B Procedure P0715 Rev September 22, 2000
P0715 Rev. September 22, 2000 W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission FUNCTIONAL TEST PROCEDURE FOR THE GYROSCOPE
More informationMar11 Rev C
Product Specification 108-1956 11Mar11 Rev C PC/104 and PC/104-Plus Connector Systems 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the TE Connectivity
More informationCPT-COM-U Card. TTL Serial USB Isolated Interface Board. Technical Brief
CPT-COM-U Card TTL Serial USB Isolated Interface Board Technical Brief June 2014 Manual Release 1.0 Card Version 1.1 Copyright 2014 Creative Power Technologies P/L P.O. Box 714 MULGRAVE Victoria, 3170
More informationW. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA Gravity Probe B Relativity Mission
W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission Payload Magnetometer Test Readiness Review Completion Certificate GP-B
More informationREPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:
Page 1 of 64 National 1536 East Valencia Drive Technical Fullerton, California 92831 Systems Tel: 714-879-6110 Fax: 714-879-6117 www.ntscorp.com REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED
More informationLAT-TD DRAFT 06/24/2005. PDU Performance Test Procedure. P. Young LAT-TD
Document # Date effective LAT-TD-01744-03 DRAFT 06/24/2005 Author(s) Supersedes P. Young LAT-TD-01744-02 Document Title PDU Performance Test Procedure Subsystem/Office Electronics & DAQ Subsystem revision.
More informationI&T&C Organization Chart
I&T&C Organization Chart I&T&C Manager Elliott Bloom WBS 4.1.9 I&T Engineer B. Grist WBS 4.1.9.1 Reliability & QA D. Marsh WBS 4.1.9.2 Mechanical Ground Support Equipment TBD Instrument Operations Coordinator
More informationECU / PROTON DETECTOR INTERFACE CHECKOUT
Stanford University Program Procedure No. P0626 Rev. Operation Order No. GRAVITY PROBE B PROCEDURE FOR BOX LEVEL / THERMAL VAC TESTING ECU / PROTON DETECTOR INTERFACE CHECKOUT Procedure No. P0626 Rev.
More informationLAT-TD DRAFT 10/05/2005. PDU Performance Test Procedure. P. Young LAT-TD
Document # Date effective LAT-TD-01744-05 DRAFT 10/05/2005 Author(s) Supersedes P. Young LAT-TD-01744-04 Document Title PDU Performance Test Procedure Subsystem/Office Electronics & DAQ Subsystem revision.
More informationSouthern Africa Large Telescope. Prime Focus Imaging Spectrograph. Rutgers Etalon Subsystem. Interface Control Document
Southern Africa Large Telescope Prime Focus Imaging Spectrograph Rutgers Etalon Subsystem Interface Control Document Revision 1.3 01 August 2001 1 Scope... 3 2 Optical... 4 2.1 Collimation... 4 3 Mechanical...
More informationAug04 Rev D EC
Product Specification 108-1163 18Aug04 Rev D EC 0990-1127-04 Modular Plugs, Thru-Hole and Surface Mount Jacks, Data and Telephone, PCB Mounted 1. SCOPE 1.1. Content This specification covers the performance,
More informationProduct Specification AMP Connector USB Consortium, Plug & Receptacle. Lead Free Version
Product Specification 108-60034 AMP Connector USB Consortium, Plug & Receptacle Lead Free Version 1. Scope: 1.1 Contents: This specification covers the requirements for product performance, test methods
More informationOHB System AG International Conference on Space Optics ICSO 2016 Prepared by Raffello MIGLIORE Date , Biarritz.
International Conference on Space Optics ICSO 2016 Prepared by Raffello MIGLIORE Date 19.10.2016, Biarritz Outlook on EDRS-C EDRS-C / European Data Relay System EDRS-C, designed and developed by OHB System,
More informationELECTRICAL TEST PROCEDURE (ETP) FOR ECU SPACECRAFT EMULATOR GSE SN: 001. GP-B Procedure P0847 Rev -
0847 Rev. W. W. Hansen Experimental hysics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity robe B Relativity Mission ELECTRICAL TEST ROCEDURE (ET) FOR ECU SACECRAFT EMULATOR GSE
More informationPRODUCT SPECIFCATION GS MINI-SAS HD External Cable to Board Connector System. 1 of 14 F. Roger Cheng TYPE NUMBER
1 of 14 F TABLE OF CONTENTS 1.0 OBJECTIVE... 3 2.0 SCOPE... 3 3.0 APPLICABLE DOCUMENTS... 3 3.1 FCI SPECIFICATIONS... 3 3.2 OTHER STANDARDS AND SPECIFICATIONS... 3 3.3 FCI PRODUCT QUALIFICATION TEST REPORTS...
More informationSOFTWARE OPERATING PROCEDURE (SOP) FOR GSS LVA WIGGLE OPERATIONS SN: GP-B Procedure P0848 Rev -
W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission SOFTWARE OPERATING PROCEDURE (SOP) FOR GSS LVA WIGGLE OPERATIONS SN:
More informationCoda cx1 Short Form Functional Test Procedure
Coda cx1 Short Form Functional Test Procedure CDL 1-TP07-0100:0208 MIT Ref. 85-01050.01 Revision 1.0 28 th March 2002 CDL 1-TP07-0100:0208 Contents 1 Introduction... 1 1.1 Activity Description... 1 1.2
More informationCOOL-COVERINGS. André Santos, The Netherlands Copyright Active Space Technologies
COOL-COVERINGS André Santos, The Netherlands 21-03-2012 Copyright Active Space Technologies 2004-2011 Young and competent company Started in 2007 in Germany, in 2004 in Portugal Role Support scientific
More informationBS EN 1789:2007 Certificate of Compliance
BS EN 1789:2007 Certificate of Compliance VCA Headquarters 1 The Eastgate Office Centre Eastgate Road Bristol, BS5 6XX United Kingdom Switchboard: +44 (0) 117 951 5151 Main Fax: +44 (0) 117 952 4103 Email:
More informationBOARD-LEVEL TEST PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM (GSS) MUX/OSCILLATOR/CHARGE CTRL (MUX) BOARD. GP-B Procedure P0607 Rev -
W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission BOARD-LEVEL TEST PROCEDURE FOR THE GYROSCOPE SUSPENSION SYSTEM (GSS)
More informationPDS: Rev :A STATUS:Released Printed: Jan 04, 2012
of 2 A.0 Objective This specification defines the performance, test, quality and reliability requirements of the USB3.0 Standard- A Receptacle. 2.0 Scope This specification is applicable to the termination
More informationLAT PROJECT DOCUMENT CHANGE NOTICE (DCN) SHEET 1 OF 1
DCN No. LAT-XR-05484-01 LAT PROJECT DOCUMENT CHANGE NOTICE (DCN) SHEET 1 OF 1 ORIGINATOR: Dave Nelson PHONE: 650-926-4652 DATE: 12/15/04 CHANGE TITLE: DCN for TPS Assembly CPT/LPT Test Procedure ORG.:
More informationPRE-ASSEMBLY COMPONENT MATCHING PROCEDURE FOR THE HVA PWA OPTOCOUPLERS. GP-B Procedure P0716 Rev A August 21, 2000
W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA 94305-4085 Gravity Probe B Relativity Mission PRE-ASSEMBLY COMPONENT MATCHING PROCEDURE FOR THE HVA PWA OPTOCOUPLERS
More informationPRODUCT SPECIFICATION
SIM Card Connector, Hinged Type, 8 Pin, SMT, 1.50mm Profile. Page 1 SIM Card Connector, Hinged Type, 8 Pin, SMT, 1.50mm Profile. Page 2 1.0 SCOPE. This specification covers performance, tests and quality
More informationApproval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date
ATS-ATP-3441 Page: 1 of 5 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013
More informationAccreditation Body Evaluation Procedure for AASHTO R18 Accreditation
Accreditation Body Evaluation Procedure for AASHTO R18 Accreditation Final August 9, 2016 Page 1 of 12 Section Number Table of Contents Title of Section 0 Purpose 1 Scope 2 References 3 Objectives 4 Criteria
More informationPRODUCT SPECIFICATION
1.0 SCOPE DDR4 DIMM SOCKET This Product Specification covers the 0.85mm centerline gold plated DDR4 DIMM edge card connector for 1.40 ± 0.10 thick memory modules..0 PRODUCT DESCRIPTION.1 PRODUCT NAME AND
More informationREPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED ON GPS ANTENNA PART NUMBER 42G1215A-XT-1-N PREPARED FOR:
Page 1 of 40 National 1536 East Valencia Drive Technical Fullerton, California 92831 Systems Tel: 714-879-6110 Fax: 714-879-6117 www.ntscorp.com REPORT OF ELECTROMAGNETIC SUSCEPTIBILITY TESTS PERFORMED
More informationPRODUCT SPECIFICATION CUSTOM CONFIGURABLE MODULAR POWER DOCK CONNECTOR SYSTEM
1.0 SCOPE This Product Specification covers the custom configurable modular printed circuit board (PCB) Dock Connector System with gold plating. 2.0 PRODUCT DESCRIPTION 2.1 PRODUCT NAME AND SERIES NUMBER(S)
More informationESD CONTROL SURVEY - REPORT
ESD CONTROL SURVEY - REPORT Survey for: Kruizinga B.V. Address: Ir. R.R. van der Zeelaan 1 8191 JH WAPENVELD The Netherlands For: Mr. F. Vorderman Survey Date: 16-03-2015 Prepared by: Marco Waarma Copy
More information[0.057] 5.8 [0.23]
Product Specification 7 March 13 Rev A1 SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More informationNeXLev Product Specification TB2144
NeXLev Product Specification TB2144 Revision B Specification Revision Status Revision SCR No. Description Initial Date - S0161 New Release DM 4/5/2006 A S1357 Update copper material callout, DM 8/31/09
More informationStandard specifications RS007LFF60
Standard specifications RS007LFF60 December 05, 2017 KAWASAKI HEAVY INDUSTRIES, LTD. ROBOT DIVISION Materials and specifications are subject to change without notice. Specification : (Arm): (Controller):
More informationEC Type Examination Certificate
EC Type Examination Certificate No. DK 0199.514 FT-10 Fill AUTOMATIC GRAVIMETRIC FILLING INSTRUMENT Issued by DELTA Danish Electronics, Light & Acoustics EU - Notified Body No. 0199 In accordance with
More informationCRaTER Scence Operation Center Requirements Document. Dwg. No
Rev. ECO Description Author Approved Date 01 32-157 Initial Release for comment RFGoeke 7/27/06 CRaTER Scence Operation Center Requirements Document Dwg. No. 32-01209 Revision 01 July 26, 2006 32-01209
More informationDTI HEAVYWEIGHT HIGH IMPACT (H.I.) SHOCK TEST REPORT
DTI HEAVYWEIGHT HIGH IMPACT (H.I.) SHOCK TEST REPORT July, 2003 Dynamic Testing A Division of DTI Holdings, LLC P.O. Box 494, 3915 Sunnymeade Rd., Rustburg, VA 24588 434-846-0244 dti@dynatest.net TABLE
More informationStellar Instruments. SC1 Controller & Display System. General User s Manual. Copyright 2013 Stellar Instruments 1
Stellar Instruments SC1 Controller & Display System General User s Manual Copyright 2013 Stellar Instruments 1 Contents Section 1 General... 3 Section 2 Base Unit A (Multi-Event Programmable Timer)...
More informationCONTROLLED DISTRIBUTION REFERENCE
ISSUE : 01 PAGE: 2/14 CHANGE RECORDS ISSUE DATE CHANGE RECORDS AUTHOR 01 26/05/09 First issue MS - PF ISSUE : 01 PAGE: 3/14 TABLE OF CONTENTS 1. PURPOSE... 4 2. DOCUMENTS... 5 2.1 Normative Documents...5
More informationAUDIT PROGRAM. Revision 6 Dated September 29, Management Systems Analysis, Inc. P.O. Box 136, Royersford, PA
AUDIT PROGRAM Revision 6 Dated September 29, 2010 Management Systems Analysis, Inc. P.O. Box 136, Royersford, PA 19468 610-409-0168 jhighl@aol.com Approved: 1.0 Objective 2.0 Scope 3.0 General To describe
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationKR QUANTEC K ultra. Robots. With F Variants Specification. KUKA Roboter GmbH. Issued: Version: Spez KR QUANTEC K ultra V10 KR QUANTEC
Robots KUKA Roboter GmbH KR QUANTEC K ultra With F Variants Specification KR QUANTEC K ultra Issued: 02.09.2016 Version: Spez KR QUANTEC K ultra V10 Copyright 2016 KUKA Roboter GmbH Zugspitzstraße 140
More informationDOCUMENTATION AND QUALITY ASSURANCE
SPECIFICATION PREFACE SHEET DEPARTMENT: Engineering / Instrumentation SHEET 1 OF 12 AREA: Grundartangi Reduction Plant SPEC No: 00/07/TS012 REV: C2 STANDARD TECHNICAL SPECIFICATION FOR DOCUMENTATION AND
More informationNIR Moisture Analyzer KB-30
NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property
More informationProduct Specifications and Usage Information P4350 & P4355 MX2 Laser Micrometer and Gauge Blocks
DESCRIPTION The P4350 MX2 Laser Micrometer is a component of the DoseControl Dosimetry System used to measure the thickness of Harwell PMMA (Perspex) Dosimeters. The MX2 is designed to be mounted, connected,
More informationPRODUCT SPECIFICATION
SIM Card Connector, Hinged Type, 6 Pin, SMT, 1.85mm Profile. Page 1 SIM Card Connector, Hinged Type, 6 Pin, SMT, 1.85mm Profile. Page 2 1.0 SCOPE. This specification covers performance, tests and quality
More informationProton Launch System Mission Planner s Guide APPENDIX D. Adapter Systems
Proton Launch System Mission Planner s Guide APPENDIX D Adapter Systems D. ADAPTER SYSTEMS This appendix presents information on Adapter Systems (AS) that may be used for commercial launches with the
More informationFlat. PITK-W025B Flat 23W LED Driver. Features. Specification Summary. Input Specifications 1 / V / 0.57A / 23W. Mechanical Outline
PITK-W025B Flat 23W LED Driver 25-40V / 0.57A / 23W Features Constant Current Control Fixed Output Current Active Power Factor Correction Protection : OVP, SCP KS C 7655 Safety Certifications Approved
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationGrayhill, Inc. La Grange, IL
Device Under Test: 62SY15045 Physical Test: Dimensional, Mechanical Vibration, Mechanical Shock Electrical Test: Contact Resistance, Thermal Shock Test Report Number: SP02-1875 Test Start Date: January
More informationInterfaces Module Exploration Systems Engineering, version 1.0
nterfaces Module Exploration Systems Engineering, version 1.0 Exploration Systems Engineering: nterfaces Module Module Purpose: nterfaces Define interfaces, how they are described and why it is important
More informationAMP-TWIST* 6S Series SL Jack
Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*
More informationSPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM
SPECIFICATION FOR THE SUPPLY OF A BATTERY MONITORING SYSTEM ESG20020202-3-2 February 27 th 2008 Project number reference:- File Number:- Prepared by:- Company:- Address:- Copy Number:- of Intentionally
More informationEQUIPMENT INSTALLATION MANUAL. for the GDC66 FUEL QUANTITY ADAPTER UNIT P/N Rev B
EQUIPMENT INSTALLATION MANUAL for the GDC66 FUEL QUANTITY ADAPTER UNIT P/N 1107-4000-01 Rev B DAC International 6702 McNeil Drive Austin, TX 78729 Copyright 2013, DAC International. All rights reserved.
More informationMOUNT PROBE ONTO PRECISION MANIPULATOR
SU/GP-B STANFORD UNIVERSITY W.W. HANSEN EXPERIMENTAL PHYSICS LABORATORY GRAVITY PROBE B, RELATIVITY GYROSCOPE EXPERIMENT STANFORD, CALIFORNIA 94305-4085 MOUNT PROBE ONTO PRECISION MANIPULATOR GP-B SCIENCE
More informationIC693 PLC IC693ACC350, IC693ACC340/341
March 29, 2001 IC693 PLC IC693ACC350, IC693ACC340/341 Redundant Power Supply System he IC693 Redundant Power Supply System consists of a Baseplate and an Adapter, described below. Redundant Power Supply
More informationLED light engines ready2apply
Module DLA G system data sheet Engine DLA G Product description LED replacement for downlight with compact fluorescent lamps Complete solution comprising module, driver, reflector and trim ring Tool-free
More informationSmiths Connectors Sabritec Test Report High Speed and Durability Test Quadrax Pin Contact & SKT Contacts
Smiths Connectors Sabritec Test Report High Speed and Durability Test Quadrax Pin Contact 019135-8019 & SKT Contacts 019235-8019 Rev. A 11-16-2011 www.smithsconnectors.com Revision Letter Page Number Paragraph
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD First edition 199-05- Information technology - Data interchange on 10 mm optical disk cartridges of type WORM (Write Once Read Many) using irreversible effects - Capacity:,6 Gbytes
More informationGROUND FAULT CIRCUIT INTERUPTERS
Title: GFCI Effective Date: 11/14/2014 Control Number: THG_0031 Revision Number: 1 Date: 10/21/2015 Annual Review Completed: 5/13/2015 GROUND FAULT CIRCUIT INTERUPTERS CONTENTS I. PURPOSE II. GENERAL REQUIREMENTS
More informationPower Supply (48Vdc, 2.5A)
Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.
More informationNON-LINEAR ENGINE COMPONENT FAULT DIAGNOSIS FROM A LIMITED NUMBER OF MEASUREMENTS USING A COMBINATORIAL APPROACH
NON-LINEAR ENGINE COMPONENT FAULT DIAGNOSIS FROM A LIMITED NUMBER OF MEASUREMENTS USING A COMBINATORIAL APPROACH N. Aretakis Research associate K. Mathioudakis Associate Professor A. Stamatis Research
More informationRI AND RF CRITERIA AND FORMATS
RI-42 RI AND RF CRITERIA AND FORMATS PURPOSE This procedure establishes design criteria and standard formats for detailed procedures and records required for effective operations, communications and management
More information