Data Communication and Telecommunication Surge Suppression
|
|
- Sarah Cannon
- 5 years ago
- Views:
Transcription
1 Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective September 2006 New Information Contents ECCP EDDP EMTJ EPCH Coaxial or twinaxial-based networked equipment running IBM 3270, AS400, Ethernet, satellite/cable/ closed circuit TV and most other wideband, communication interfaces Hubs, bridges, routers, switches and other networked equipment running 10Base-T and 100Base-T Ethernet, RS-422, RS-423, RS-232, Analog Dial-up, CSU/DSU, DDS, ISDN, T1 and most other communication environments LAN interface technologies such as Ethernet, 10/100Base-T, CAT5, CAT5e, CAT6 and Power over Ethernet (PoE) Protected patch panels CAT5 Ethernet, 100Base-T, T1, ISDN, and telco protocols ERAK ESIP ETSP Rack-mount and wall-mount standoff protectors 10Base-T and 100Base-T Ethernet, PoE, Cable, CCTV, RS-422, RS-232, ISDN, T1, DDS, Dial-up, and most other communication interfaces Parallel and serial devices such as printers and external modems, point-of-sale terminals, mainframes, dumb terminals, and most other devices using Subminiature D connectors. Includes Ethernet, RS-232, RS-422 and LAN/WAN interfaces Networked equipment connected to RS-422, RS-232, Muxes, DDS, Analog Dial-up, ISDN, T1 and most other communication interfaces
2 ECCP Series Data Line Surge Protection Introduction The ECCP Series of data communication line surge protectors will ensure the reliable operation of coaxial or twinaxial based networked equipment running IBM 3270, AS400, Ethernet, satellite/ cable/closed circuit TV and most other wideband, communication interfaces. ECCPs Offer: State-of-the-art, avalanche diode and thyristor technology. Compact, in-line installation. High-speed, high-energy handling capability. Low shunt capacitance to reduce signal loss. You Receive: Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Protection at the interface card. Adaptability to most industry applications. The ECCP Series devices guard sensitive data networks against lightning induced surges, ac power interference, electrostatic discharge and ground loop energies. Typical applications include: CCTV cameras, residential cable installations, terminals, file servers, repeaters and mainframes using Ethernet and most other communication applications. High-speed avalanche diode technology is used in conjunction with low capacitance circuitry, enabling the protectors to function at a much greater bandwidth without causing signal degradation. This, in combination with their small size, makes the ECCP exceedingly versatile. Standard units protect both center conductor(s) and shield circuits. A separate grounding wire on all units provides an isolated path to ground without adding an additional ground connection to the shield or network ground point. ECCPs can also be specially configured to accommodate other standard connector interfaces (F, N, BNC, etc.). A wide selection of clamping voltages is available. Installation To install, insert the protector in series between the incoming communication line and the I/O port of the equipment to be protected. The protector ground wire must be connected to the metal chassis of the equipment being protected. Units should be installed at both ends of the data cable for the most effective protection. Warranty Caution GROUND WIRE MUST BE GROUNDED DIRECTLY TO THE METAL CHASSIS OF THE EQUIPMENT BEING PROTECTED. THE EQUIPMENT CHASSIS MUST BE CONNECTED TO EARTH THROUGH A PROPERLY GROUNDED AC POWER RECEPTACLE. Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 2 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
3 Technical Data TABLE 1. ECCP ELECTRICAL SPECIFICATIONS SPECIFICATION STANDARD CLAMP VOLTAGE 8/20 microseconds for ECCP-CMS. 1.5 GHz for ECCP-CMS. PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME MAXIMUM SHUNT CAPACITANCE SERIES RESISTANCE Ethernet 7.5 Volts 132 Amps < 5 Nanoseconds <30 pf None -0.5 db CCTV 7.5 Volts 132 Amps < 5 Nanoseconds <30 pf None -0.5 db Cable/Satellite TV 90 Volts 20 ka < 5 Nanoseconds 1 pf None <1 db AS400/3X Twinaxial 10 Volts 103 Amps < 5 Nanoseconds <30 pf None -0.5 db INSERTION LOSS AT 40 MHZ TABLE 2. ECCP SYSTEM APPLICATION AND CATALOG NUMBERS CONNECTOR TYPE ETHERNET 10BASE-2 ETHERNET 10BASE-5 CCTV CABLE/SATELLITE TV AS400/3X TWINAXIAL BNC TEE Configuration (Figure A) ECCP-2DT (EN) BNC Male/Female Straight (Figure B) ECCP-2DA (EN) BNC Male/Female Straight (Not Shown) ECCP-CCTV Twinaxial Female/Female (Figure C) ECCP-2BM F/F Twinaxial Male/Female (Figure D) ECCP-2BM M/F N Series Female/Female (Figure E) ECCP-2DA N (EN) F/F N Series Male/Female (Figure F) ECCP-2DA N (EN) M/F F Series Female/Female (Figure G) ECCP-CMS F/F & M/F See Ordering Guidelines below. ECCP-CMS types are not UL listed. Note: See Figure 1 below. Special configurations available (82.5) Figure A 1.45 (36.8) 3.43 (87.1) Figure B 0.90 (22.9) 4.70 (119.4) Figure C 4.70 (119.4) Figure D 4.40 (111.8) Figure E 0.77 (19.6) 4.40 (111.8) Figure F 0.90 (22.9) 3.33 (84.6) Figure G 0.90 (22.9) FIGURE 1. ECCP CONNECTOR TYPE CONFIGURATIONS Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: ECCP-2DA N (EN) F/F = ECCP2DANENFF. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
4 EDDP Series Data Line Surge Protection Introduction The EDDP Series of data communication line protectors will ensure the reliable operation of hubs, bridges, routers, switches and other networked equipment running 10Base-T and 100Base-T Ethernet, RS-422, RS-423, RS-232, Analog Dial-up, CSU/DSU, DDS, ISDN, T1 and most other communication environments. EDDPs Offer: State-of-the-art, avalanche diode and thyristor technology. Compact, in-line installation. High-speed, high-energy handling capability. Low shunt capacitance to reduce signal loss. You Receive: Ideal for LAN Hubs, Concentrators and Mu Multiport Interfaces Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Protection at the interface card. Adaptability to most industry applications. Transient surges can enter electronic equipment through any pathway provided. If a facility has a reliable ac power protection system in place, transient surge energies can still be generated within a building by sources such as inductive load switching, ground loop currents and electrostatic discharge. These surge energies are clamped by the ac power protector into the communication ground, damaging expensive communications hardware. Eaton protectors are specifically designed to give added security to electronic devices with extremely low tolerance for voltage rises or ground loop energies. This protection is particularly important for equipment networked at distances greater than 30 feet (9 m) and installations in high lightning areas. EDDP models protect virtually any communication interface including: 10Base-T and 100Base-T Ethernet, RS-422, RS-232, RS-423 and most high-speed LAN/WAN interfaces. Combined into a compact interface unit, the devices exhibit an extremely fast response time of less than 5 nanoseconds. All these features make EDDP protectors the most cost-effective and versatile devices of their kind available today. Whether you need to protect a single communication line, or an entire installation, Eaton s EDDP Series protectors are an easy, cost-effective solution to overvoltage problems. Installation To install, insert the protector in series between the incoming communication line and the I/O port of the equipment to be protected. The protector ground wire must be connected to the metal chassis of the equipment being protected. Units should be installed at both ends of the data cable for the most effective protection. Warranty Caution GROUND WIRE MUST BE GROUNDED DIRECTLY TO THE METAL CHASSIS OF THE EQUIPMENT BEING PROTECTED. THE EQUIPMENT CHASSIS MUST BE CONNECTED TO EARTH THROUGH A PROPERLY GROUNDED AC POWER RECEPTACLE. Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 4 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
5 Technical Data TABLE 3. EDDP ELECTRICAL SPECIFICATIONS SPECIFICATION STANDARD CLAMP VOLTAGE PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME 10/100Base-T 7.5 Volts 132 Amps < 5 Nanoseconds <40 pf RS-422, RS-485, RS-423 RS Volts 60 Amps < 5 Nanoseconds <40 pf CSU/DSU 60 Volts 50 Amps < 5 Nanoseconds <75 pf Non-Span T1 (Fused) Dial-up Modem/Fax (Fused) 240 Volts 75 Amps < 5 Nanoseconds <95 pf MAXIMUM SHUNT CAPACITANCE TABLE 4. EDDP SYSTEM APPLICATION AND CATALOG NUMBERS CONNECTOR TYPE Single RJ21 Protects 25 Pairs (50 Wires) (Figure A) Double RJ21 Protects 50 Pairs (100 Wires) Not Shown 4-Position RJ45/RJ11 Hub Protector (Figure B) 8-Position RJ45/RJ11 Hub Protector (Not Shown) 12-Position RJ45/RJ11 Hub Protector (Figure C) See Ordering Guidelines below. 10BASE-T ETHERNET, RS-422, RS-485, RS BASE-T RS-232 CSU/DSU NON- SPAN T1 (FUSED) DIAL-UP MODEM/ FAX (FUSED) EDDP-25-E EDDP-25-T EDDP-25-B EDDP-25-G EDDP-50-E EDDP-50-T EDDP-50-B EDDP-50-G EDDP-H4-E EDDP-H4-E-C5 EDDP-H4-T EDDP-H4-B EDDP-H4-G EDDP-H8-E EDDP-H8-E-C5 EDDP-H8-T EDDP-H8-B EDDP-H8-G EDDP-H12-E EDDP-H12-E-C5 EDDP-H12-T EDDP-H12-B EDDP-H12-G Note: See Figure 2 below. Special configurations available. Figure A: Figure B: Figure C: FIGURE 2. EDDP CONNECTOR TYPE CONFIGURATIONS Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: EDDP-H4-T = EDDPH4T. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
6 EMTJ Series Data Line Surge Protection Introduction The EMTJ Series of surge protectors for RJ45 and RJ11 connectors will ensure the reliable operations of devices in a wide variety of environments. We offer protection for LAN interface technologies such as Ethernet,10/100Base-T, CAT5, CAT5e, CAT6, and Power over Ethernet. For WAN and Telco applications, we offer protection for ISDN, T-1, E-1, DDS, analog dial-ups, and more. Additionally, our Custom Products Division provides a solution for almost any application that sends data, voice or video over copper interconnects. EMTJs Offer: State-of-the-art, avalanche diode and thyristor technology. Compact, in-line installation. High-speed, high-energy handling capability. Low shunt capacitance to reduce signal loss. You Receive: Ideal for RJ11 and RJ 45 Style Twisted Pair Interfaces Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Protection at the interface card. Adaptability to most industry applications. The EMTJ Series devices guard sensitive data networks against lightning induced surges, ac power interference, electrostatic discharge, and ground loop energies. Typical applications include: NICs, switches, hubs, repeaters, bridges, routers, point-of-sale terminals, modems, fax machines, telephones and most other types of communications equipment utilizing RJ45 or RJ11 modular telephone jacks. High-speed avalanche diode technology is used in conjunction with low capacitance circuitry, enabling the protectors to function at a much greater bandwidth without causing signal degradation. Standard units are available with up to 8 wires protected on the RJ45 devices, and up to 6 wires protected on the RJ11 device. All this, in combination with their small size, makes the EMTJ exceedingly versatile. Installation To install, insert the protector in series between the incoming communication line and the I/O port of the equipment to be protected. The protector ground wire must be connected to the metal chassis of the equipment being protected. Units should be installed at both ends of the data cable for the most effective protection. Warranty Caution GROUND WIRE MUST BE GROUNDED DIRECTLY TO THE METAL CHASSIS OF THE EQUIPMENT BEING PROTECTED. THE EQUIPMENT CHASSIS MUST BE CONNECTED TO EARTH THROUGH A PROPERLY GROUNDED AC POWER RECEPTACLE. Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 6-inch RJ11 or RJ45, Male/Male Adapter 0.92 (23.4) 1.47 (37.3) 3.60 (91.4) All Products (Except CAT6 - PPC) 14 Awg Ground Wire, 10-inch Length with #6 Fork Terminal 9' Cord Set RJ11 or RJ 45 Male/Male Adapter 1' Cord Set RJ11 or RJ45 Male/Male Adapter 0.92 (23.4) 3.60 (91.4) 14 Awg Ground Wire, 10-inch Length with #6 Fork Terminal FIGURE 3. EMTJ SCHEMATIC 1.47 (37.3) CAT 6 - PPC Only 6 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
7 Technical Data TABLE 5. EMTJ ELECTRICAL SPECIFICATIONS SPECIFICATION Note: Subject to change without notice. STANDARD CLAMP VOLTAGE PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME MAXIMUM SHUNT CAPACITANCE 10Base-T RS/422/ Volts 132 Amps < 5 Nanoseconds <40 pf 100Base-T Ethernet CAT5/5e 12 Volts 97 Amps < 5 Nanoseconds <25 pf 1000Base-T Ethernet CAT6 7.5 Volts 132 Amps < 5 Nanoseconds <5 pf (Device Only) Power over Ethernet Pins 1, 2, 3 & Volts Pins 1, 2, 3 & Amps < 5 Nanoseconds <25 pf (Ethernet Lines Only) Pins 4, 5, 7 & 8 60 Volts Pins 4, 5, 7 & 8 50 Amps RS Volts 60 Amps < 5 Nanoseconds <40 pf Digital, ISDN, DDS, T-1/E-1, CSU/DSU 60 Volts 50 Amps < 5 Nanoseconds <75 pf Analog Dial-up/Modem Fax 240 Volts 75 Amps < 5 Nanoseconds <95 pf TABLE 6. EMTJ SYSTEM APPLICATION AND CATALOG NUMBERS APPLICATION WIRES PROTECTED 10BASE-T ETHERNET 100BASE-T ETHERNET RS-422/RS-423 RS-232 CSU/DSU ISDN RJ-11 RJ-11 RJ-11 2 Wire, 2 Center Pins 4 Wire, 4 Center Pins 6 Wire, All Pins 1, 2, 3, 6 1, 2, 4, 5 1, 2, 7, 8 4 Wire, 4 Center Pins 8 Wire, All Pins EMTJ04E/RJ45 EMTJ08E/RJ45 EMTJ-C5E EMTJ04E/RJ11 EMTJ06E/RJ11 EMTJ04E/RJ45-C EMTJ08E/RJ45 EMTJ04T/RJ45 EMTJ08T/RJ45 EMTJ-ISDN EMTJ-DIGITAL EMTJ-ISDN APPLICATION WIRES PROTECTED DDS T1 DIAL-UP MODEM/ FAX 1000BASE-T ETHERNET CAT6 POWER OVER ETHERNET RJ-11 RJ-11 RJ-11 2 Wire, 2 Center Pins 4 Wire,4 Center Pins 6 Wire, All Pins 1, 2, 3, 6 1, 2, 4, 5 1, 2, 7, 8 4 Wire, 4 Center Pins 8 Wire, All Pins EMTJ-DDS EMTJ-DIGITAL EMTJ-T1 EMTJ-DIGITAL EMTJ02G/RJ11 EMTJ04G/RJ11 EMTJ06G/RJ11 EMTJ08G/RJ45 CAT6-PPC EMTJ-PoE 60V See Ordering Guidelines below. With pins 1 and 8 passed through. Not UL listed. Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: EMTJ04E/RJ45-C = EMTJ04ERJ45C. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
8 EPCH Series Data Line Surge Protection Ideal for 19" Relay Rack Applications Supporting Hubs, Routers, Switches, ISDN, T1, Telco and Other High-Speed Communications/Networking Equipment Introduction The EPCH Series of Protected Patch Panels helps ensure the reliable operation of equipment utilizing CAT5 Ethernet, 100Base-T, T1, ISDN, and telco protocols where system availability is absolutely critical. EPCHs Offer: State-of-the-art, avalanche diode and thyristor technology. Self-resetting, 1500 watt, bi-directional circuit. Convenient, integral, wiring management system. You Receive: Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Adaptability to most industry applications. The EPCH Series is a 110 IDC (Insulation Displacement Contact) to RJ45 patch panel with built-in surge protection. These devices help guard sensitive, high-speed communication equipment from system damage, data loss and downtime resulting from the effects of lightning, surges, electrostatic discharge and other induced voltages on data lines. EPCH units include industrystandard, 19-inch rack-mounting for structured cabling environments, TIA/EIA-568-A compliance, and an extremely fast response time of less than 5 nanoseconds. Convenient, built-in, all-wire protection makes this patch panel cost-effective and a real time saver. Designed for high-speed data, voice and multimedia applications in structured cabling environments for medium to large-size businesses today, these units incorporate the latest in communication protection technology for mission-critical installations. The self-resetting, 1500 watt, bi-directional circuit provides maximum reliability. Overvoltages are safely shunted to ground via an 11-inch braided wire and chassis frame for maximum protection. Installation Remove power to the unprotected equipment. Mount the patch panel to your 19-inch relay rack using the supplied hardware. Disconnect the incoming data lines from the equipment. Attach the ground strap to your rack. The installer should confirm a proper rack to earth ground connection. Consult with an electrician if needed. Try to keep the resistance from the supplied fork terminal ground to the rack frame minimal. It is imperative that both the EPCH and the equipment to be protected are properly grounded for effective operation. Using a 110 punch-down tool, install the cable AWG wire matching the color code on the 110 IDC. Maintain pair twist, up to point of termination, for maximum performance (untwist less than 0.5 of an inch). Connect the patch panel to the equipment. Note: These protectors reset themselves after protecting equipment from surges. In the event that lightning or other extreme surge events have exceeded the maximum capability of the protector, these devices are designed to self-destruct in a "fail-safe" mode rather than allow damage to equipment. Installations often require a protector at each end of the data line (call our technical support group with any questions). Warranty Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 8 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
9 Technical Data TABLE 7. EPCH ELECTRICAL SPECIFICATIONS SPECIFICATION STANDARD CLAMP VOLTAGE PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME 10/100Base-T 12 Volts 97 Amps < 5 Nanoseconds <25 pf CAT5 Ethernet ISDN, T1, DDS (Fused) 60 Volts 50 Amps < 5 Nanoseconds <75 pf Dial-up, Modem/Fax (Fused) 240 Volts 75 Amps < 5 Nanoseconds <95 pf MAXIMUM SHUNT CAPACITANCE TABLE 8. EPCH SYSTEM APPLICATION AND CATALOG NUMBERS CONNECTOR TYPE 12-Port Flush-mount Unit 110 Block to RJ45 (Not Shown) 24-Port Flush-mount Unit 110 Block to RJ45 48-Port Stand-off Unit 110 Block to RJ45 (Not Shown) See Ordering Guidelines below. Not UL listed. 10BASE-T CAT5 ETHERNET ISDN, T1, DDS (FUSED) DIAL-UP MODEM/ FAX (FUSED) All Pins EPCH12-C5 Center 4 Pins (8-Pin Version Available) EPCH12-RJ45-B EPCH12-RJ45-G All Pins EPCH24-C5 All Pins EPCH48-C5 Note: See Figure 4 below. Special configurations available (482.6) 0.62 (15.7) 2.87 (72.8) 3.50 (88.9) FIGURE 4. EPCH CONNECTOR TYPE DIMENSIONS Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: EPCH12-RJ45-B = EPCH12RJ45B. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
10 ERAK Series Data Line Surge Protection Ideal for 19" Relay Racks Supporting LAN Hubs, Concentrators and Multi-Port Interfaces Introduction The ERAK Series of Rack-Mount and Wall-Mount Standoff protectors will ensure the reliable operation of networked equipment connected to 10Base-T and 100Base-T Ethernet, Power over Ethernet (PoE), Cable, CCTV, RS-422, RS-232, ISDN, T1, DDS, dial-up, and most other communication interfaces. ERAKs Offer: State-of-the-art, avalanche diode and thyristor technology. Compact, in-line installation. High-speed, high-energy handling capability. Low shunt capacitance to reduce signal loss. You Receive: Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Protection at the interface card. Adaptability to most industry applications. Transient surges can enter electronic equipment through any pathway provided. Facilities with reliable ac power protectors can still experience surge-related, system downtime. Transient surge energies from sources such as inductive load switching, ground loop currents and electrostatic discharge are clamped by ac protectors into the shared communication ground, resulting in damage to expensive communication hardware. Eaton s ERAK Series includes 16 port, 19-inch relay rack protectors, as well as 16 and 32 port, 5-inch standoff units for wall-mount protection or environments where 19-inch relay rack space is limited. A wide variety of communication interfaces are supported that include 10Base-T and 100Base-T Ethernet, ATM155, CDDI, 100VG-AnyLan, RS-232, RS-422 and high-speed LAN/WAN applications. For telco requirements, we offer protection for dial-up, T1, DDS, ISDN and other lease line environments. These devices exhibit an extremely fast response time of less than 5 nanoseconds. All these features make ERAK protectors the most cost-effective and versatile devices of their kind available today. Whether you need to protect a single network concentrator, or an entire relay rack full of voltage sensitive equipment, Eaton ERAK Series protectors are an easy, cost-effective solution to overvoltage problems. Installation To install, insert the protector in series between the incoming communication line and the I/O port of the equipment to be protected. The protector ground wire must be connected to the metal chassis of the equipment being protected. Units should be installed at both ends of the data cable for the most effective protection. Caution GROUND WIRE MUST BE GROUNDED DIRECTLY TO THE METAL CHASSIS OF THE EQUIPMENT BEING PROTECTED. THE EQUIPMENT CHASSIS MUST BE CONNECTED TO EARTH THROUGH A PROPERLY GROUNDED AC POWER RECEPTACLE. Warranty Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 10 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
11 Technical Data TABLE 9. ERAK ELECTRICAL SPECIFICATIONS SPECIFICATION STANDARD CLAMP VOLTAGE PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME MAXIMUM SHUNT CAPACITANCE 10/100Base-T 7.5 Volts 132 Amps < 5 Nanoseconds <40 pf RS-422, RS-485, RS-423, Ethernet RS Volts 60 Amps < 5 Nanoseconds <40 pf ISDN, T1, DDS (Fused) 60 Volts 50 Amps < 5 Nanoseconds <75 pf Dial-up/Modem/Fax (Fused) 240 Volts 75 Amps < 5 Nanoseconds <95 pf Power over Ethernet Pins 1, 2, 3 & Volts Pins 1, 2, 3 & Amps < 5 Nanoseconds <25 pf (Ethernet Lines Only) Pins 4, 5, 7 & 8 60 Volts Pins 4, 5, 7 & 8 50 Amps CCTV 7.5 Volts 132 Amps < 5 Nanoseconds <30 pf Cable TV/Satellite 90 Volts 20 ka (8/20 msec Waveform) < 5 Nanoseconds 1 pf TABLE 10. ERAK SYSTEM APPLICATION AND CATALOG NUMBERS CONNECTOR TYPE 16-Port Flush-mount Unit (Figure A) 16-Port Stand-off Unit (Not Shown) 32-Port Stand-off Unit (Not Shown) 16-Port Flush-mount Unit (Figure B) 16-Port Flush-mount Unit Front-Accessible Modules (Figure C) All Pins Center 2 Pins All Pins Center 2 Pins All Pins Center 2 Pins See Ordering Guidelines below. UL listed. 10/100BASE- T, RS-422, RS- 485 RS-423, ETHERNET ERAK16-E ERAK16-E-C5E RS-232 Note: See Figure 5 below. Special configurations available. ISDN, T1, DDS (FUSED) DIAL-UP/ MODEM/FAX (FUSED) POWER OVER ETHERNET ERAK16-T ERAK16-B ERAK16-PoE- 60V CCTV ERAK16-G ERAK16-E-SO ERAK16-E-C5E- SO ERAK16-T-SO ERAK16-B-SO ERAK16-G-SO ERAK32-E-SO ERAK32-E-C5E- SO ERAK32-T-SO ERAK32-B-SO ERAK32-G-SO CABLE TV/ SATELLITE Coax ERAK16-BNC ERAK16-CMS ERAK16-T1-LP (482.6) 0.75 (19.0) 2U 3.15 (80.0) 1.72 (43.7) 1U (482.6) (482.6) Figure A Figure B 4.25 (107.9) 1.01 (25.6) 1.60 (40.6) Figure C FIGURE 5. ERAK CONNECTOR TYPE CONFIGURATIONS Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: ERAK32T-SO = ERAK32TSO. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
12 ESIP Series Data Line Surge Protection Introduction The ESIP Series of Subminiature D interface protectors will ensure the reliable operation of parallel and serial devices such as printers and external modems, point-of-sale terminals, mainframes, dumb terminals, and most other devices using Subminiature D connectors which are sensitive to destructive transient energies. Standard applications include Ethernet, RS-232, RS-422 and LAN/WAN interfaces. ESIPs Offer: State-of-the-art, avalanche diode and thyristor technology. Compact, in-line installation. High-speed, high-energy handling capability. Low shunt capacitance to reduce signal loss. You Receive: Ideal for Subminiature D Communication Ports Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Protection at the interface card. Adaptability to most industry applications. Transient surges can enter electronic equipment through any pathway provided and damage expensive communications hardware. If a facility has a reliable ac power protection system in place, transient surge energies can still be generated within a building by sources such as inductive load switching, ground loop currents, lightning and electrostatic discharge. ESIP Series protectors combine compact enclosures with extremely fast response times of less than 5 nanoseconds. They are specifically designed to give added security to electronic devices sensitive to voltage rises or ground loop energies and have been particularly effective in areas prone to lightning activity. Subminiature D (9,15 and 25 pin) interface connectors are available in configurations protecting all pins or specific pins as required. All these features make Eaton s ESIP protectors the most costeffective and versatile devices of their kind available today. Installation To install, insert the protector in series between the incoming communication line and the I/O port of the equipment to be protected. The protector ground wire must be connected to the metal chassis of the equipment being protected. Units should be installed at both ends of the data cable for the most effective protection. Caution GROUND WIRE MUST BE GROUNDED DIRECTLY TO THE METAL CHASSIS OF THE EQUIPMENT BEING PROTECTED. THE EQUIPMENT CHASSIS MUST BE CONNECTED TO EARTH THROUGH A PROPERLY GROUNDED AC POWER RECEPTACLE. Warranty Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 12 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
13 Technical Data TABLE 11. ESIP ELECTRICAL SPECIFICATIONS SPECIFICATION STANDARD CLAMP VOLTAGE PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME MAXIMUM SHUNT CAPACITANCE RS-422/RS-423/RS Volts 132 Amps < 5 Nanoseconds <30 pf Parallel 7.5 Volts 132 Amps < 5 Nanoseconds <30 pf RS Volts 60 Amps < 5 Nanoseconds <30 pf TABLE 12. ESIP SYSTEM APPLICATION AND CATALOG NUMBERS SERIES PINS PROTECTED DB 9 STANDARD PIN CONFIGURATIONS RS-422/RS-423/ RS-485 RS-232 ETHERNET PARALLEL Protects All Pins EDB9-RS422 EDB9-RS232 DB 15 Protects All 15 Pins (Unless Specified) EDB15-RS422 EDB15-RS232 EDB15-EN (Protects IEEE Pins) AUI DB Wire All 25 Pins Protected 4-Wire Pins (1), 2, 3, 7 & 20 8-Wire Pins (1), 2, 3, 4, 5, 6, 7, 8 & 20 EDB25-RS422 EDB25-RS232 EDB25-PARLL EDB425-RS232 EDB825-RS232 See Ordering Guidelines below. Note: Special configurations available. Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: EDB25-RS232 = EDB25RS232. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
14 ETSP Series Data Line Surge Protection Introduction The ETSP Series of terminal strip protectors will ensure the reliable operation of networked equipment connected to RS-422, RS-232, Muxes, DDS, Analog Dial-up, ISDN, T1 and most other communication interfaces. ETSPs Offer: State-of-the-art, avalanche diode and thyristor technology. Compact, in-line installation. High-speed, high-energy handling capability. Low shunt capacitance to reduce signal loss. You Receive: Affordable, superior, equipment protection. Improved reliability and maximized system up-time. Protection at the interface card. Adaptability to most industry applications. The ETSP Series devices will guard sensitive data networks against lightning induced surges, ac power interference, electrostatic discharge, and ground loop energies. Typical applications include: data communications and instrumentation interfaces using RS-422, RS-232, Muxes, CSU/DSU, T1, PLCs, and most other communication interfaces. When installed on the system I/O ports, ETSPs prevent equipment damage and system errors which are a common result of transient surge energies induced onto the communications interface and ground plane. ETSPs utilize low capacitance avalanche diode arrays for low loss, high-speed protection. These field-proven circuits offer the most dependable protection available for today s highly sensitive electronic systems. Whether you need to protect a single communication line, or an entire installation, Eaton's protectors are an easy, cost-effective solution to overvoltage problems. Installation To install, insert the protector in series between the incoming communication line and the I/O port of the equipment to be protected. The protector ground wire must be connected to the metal chassis of the equipment being protected. Units should be installed at both ends of the data cable for the most effective protection. Caution GROUND WIRE MUST BE GROUNDED DIRECTLY TO THE METAL CHASSIS OF THE EQUIPMENT BEING PROTECTED. THE EQUIPMENT CHASSIS MUST BE CONNECTED TO EARTH THROUGH A PROPERLY GROUNDED AC POWER RECEPTACLE. Warranty Eaton Corporation offers a standard 5-year warranty for data communications surge protection. For more information, visit 14 EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Effective: September 2006
15 Technical Data TABLE 13. ETSP ELECTRICAL SPECIFICATIONS SPECIFICATION STANDARD CLAMP VOLTAGE PEAK PULSE CURRENT (10/1000 US S.C. WAVEFORM AT VCL) RESPONSE TIME 10Base-T Ethernet 7.5 Volts 132 Amps < 5 Nanoseconds <40 pf RS-422, RS-485, RS Volts 132 Amps < 5 Nanoseconds <40 pf RS-232 or Digital 4 20 ma Current 18 Volts 60 Amps < 5 Nanoseconds <40 pf Loop Analog 4 20 ma Current Loop 27 Volts 40 Amps < 5 Nanoseconds <40 pf CSU/DSU, T1, DDS, ISDN (Fused) 60 Volts 50 Amps < 5 Nanoseconds <75 pf Dial-up/Modem/Fax (Fused) 240 Volts 75 Amps < 5 Nanoseconds <95 pf MAXIMUM SHUNT CAPACITANCE TABLE 14. ETSP SYSTEM APPLICATION AND CATALOG NUMBERS CONNECTOR TYPE See Ordering Guidelines below. With 6 terminals. With 8 terminals. 10BASE-T ETHERNET, RS-422, RS-485, RS- 423 Note: See Figure 6 below. Special configurations available. RS-232 OR DIGITAL 4 20 MA CURRENT LOOP ANALOG 4 20 MA CURRENT LOOP CSU/DSU, T1, DDS, ISDN (FUSED) DIAL-UP/MODEM/ FAX (FUSED) 2 Terminal Barrier Strip (Figure A) ETSP-2B-E ETSP-2B-T ETSP-2B-A ETSP-2B-B ETSP-2B-G 4 Terminal Barrier Strip (Figure A) ETSP-4B-E ETSP-4B-T ETSP-4B-A ETSP-4B-B ETSP-4B-G 6 Terminal Barrier Strip (Figure B) ETSP-6B-E ETSP-6B-T ETSP-6B-A ETSP-6B-B ETSP-6B-G 8 Terminal Barrier Strip (Figure B) ETSP-8B-E ETSP-8B-T ETSP-8B-A ETSP-8B-B ETSP-8B-G 10 Terminal Barrier Strip (Figure B) ETSP-10B-E ETSP-10B-T ETSP-10B-A ETSP-10B-B ETSP-10B-G 32 Terminal Barrier Strip (Not Shown) ETSP-32B-E ETSP-32B-T ETSP-32B-A ETSP-32B-B ETSP-32B-G 2 or 4 Positions 14 to 26 Awg Push Type Terminal Strips (Both Ends) 0.92 (23.4) 1.47 (37.3) 3.60 (91.4) Figure A 6.8 or 10 Positions 14 to 26 Awg Push Type Terminal Strips (Both Ends) 3.30 (83.8) 1.25 (31.7) 5.60 (142.2) Figure B FIGURE 6. ETSP CONNECTOR TYPE DIMENSIONS Note: All specifications and dimensions are subject to change without notice. Ordering Guidelines Note: Do not include any dashes, brackets or hyphens in the catalog numbers when ordering. Example: ETSP-2B-G = ETSP2BG. UL is a federally registered trademark of Underwriters Laboratories Inc. EATON CORPORATION Data Communication and Telecommunication Surge Suppression Technical Data TD E Copyright
16 Eaton Electrical Inc Cherrington Parkway Moon Township, PA United States tel: Eaton Corporation All Rights Reserved Printed in USA Publication No. TD E/ Z4782 September 2006
Copyright Black Box Corporation. All rights reserved.
Copyright 2000. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746 JUNE 2000 SP141A SP501A SP508A SP515A-R2 SP523A-R2 SP604A SP350A-R2 SP502A
More informationGeneral Description. Product Application. Eaton Innovative Technology Special Applications
Eaton Innovative Technology Special s Technical Data New Information Page General.............................................. 1 Product.............................................. 1 Dedicated Load
More informationMCG SURGE. Data Line Protection - Vol. 3 PROTECTION. DLP-C6-DIN DLP-C6-DIN DLP-C6-DIN. MCG Surge Protection
Data Line Protection - Vol. MCG DLP-C-DIN DLP-C-DIN DLP-C-DIN SURGE PROTECTION www.mcgsurge.com Registered to ISO 001 : 00 Certificate No. 000 QM0 1 1 1 1 1 1 1 1 1 1 1 1 1 T r ansie nt Pr o t e ctio n
More informationDBPApplication. PD Devices Ltd. Unit 1, Old Station Yard, South Brent, Devon. TQ10 9AL (0)
DBP Series Data Protection Designed for business and industrial applications, these products provide protection for local area networks, CCTV/video equipment, computer serial communication interfaces and
More informationUSER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 552 Series High Speed Telco Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M552-E Rev. G Revised 01/27/10 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301)
More informationSurge Protection for Surveillance Systems
Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:
More informationUSER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 570/580 100Base-T (CAT-5) Surge Protectors Part# 07M570/580-B Doc# 074091UB Revised 2/16/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION Patton
More informationHyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series
HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series Applications Pan-Tilt-Zoom (PTZ) analog video cameras Features Individual protection circuits for analog video
More information1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM
1993 SPECIFICATIONS CSJ 1685-05-068, ETC. & 1685-02-042 1.0 DESCRIPTION SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM THIS ITEM DESCRIBES THE OPERATION AND INSTALLATION OF AN ARTERIAL
More informationUSER MANUAL MODEL 571/ Base-T (CAT-5) Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 571/581 100Base-T (CAT-5) Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M571/581-A Doc# 074300U, Rev. B Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL
More informationModel 160. Model 186. Model 247. Surge Protective Devices. Installation & Operation Manual. Model 160. Model 186. Model 247 (EDCO RM-CX06-16R)
Surge Protective Devices Installation & Operation Manual Model 160 (16-Channel Coaxial) Model 186 (16 or 48 Channel Hi Speed Data Line Protector) Model 247 (120VAC Active Tracking Filter) Model 160 (EDCO
More informationDTK-WH8PLUS. Premium Whole House Surge Protection General Product Specifications
DTK-WH8PLUS Premium Whole House Surge Protection DITEK s WH8PLUS Whole House surge protection kit is perfect for residential builders and contractors who desire to provide an additional, valuable service
More informationUSER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors
USER MANUAL MODEL 570-R8/570-R16 580-R8/580-R16 100Base-T (CAT-5) Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part #07M570/580RC-A Doc# 074101UA Revised 2/13/97 SALES OFFICE (301)
More informationUSER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 536S 802.5 Token Ring (STP) Surge Protector C E R T I F I E D An ISO-9001 Certified Company Part# 07M536S Doc# 074171U, Rev. B Revised 1/22/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationRClamp TM 0504M RailClamp Low Capacitance TVS Diode Array PRELIMINARY Features
Description RailClamps are surge rated diode arrays designed to protect high speed data interfaces. The RClamp series has been specifically designed to protect sensitive components which are connected
More informationPoint-of-Use Surge Protection
Point-of-Use Surge Protection Point-of-use surge protection consists of a power strip with surge protection circuitry incorporated. Point-of-use surge protection should be used anywhere expensive and sensitive
More informationIndustriel Transient Beskyttelse
Industriel Transient Beskyttelse Beskyt kommunikationsudstyr med disse avancerede overspændings- og lynnedslagsbeskyttere. En nødvendighed for kritiske systemer. Undgå kostbare reparationer og systemudfald.
More informationthe data line series
the data line series 12-00131 OUTDOOR SINGLE PORT POE RJ45 SURGE ARRESTOR rev0-10/100/1000 Base-T CAT5e Protection - IEEE 802.3 A/F Power Mode B - Solid-state silicon-avalanche diodes with internal TVS
More informationSPM Series Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationSurgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/
Surgelogic Surge Protective Devices (SPDs) Residential Catalog 6671CT9701R08/12 2012 CONTENTS Whole House Surge Protective Devices (SPDs).................... 3 SDSB1175C / SDSB1175CB Whole House SPDs..................4
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationUSER MANUAL MODEL 505M-CHC. Surge Protected DB-25 to RJ-45 Modular Adapter
USER MANUAL MODEL 505M-CHC Surge Protected DB-25 to RJ-45 Modular Adapter C E R T I F I E D An ISO-9001 Certified Company Part# 07M505MCHC-A Doc# 074281U, Rev. B Revised 1/21/08 SALES OFFICE (301) 975-1000
More informationEthernet Protection A Whole Solution Han Zou, ProTek Devices
Ethernet Protection ------ A Whole Solution Han Zou, ProTek Devices Introduction: As Ethernet applications progress from 10BaseT to 10Gigabit and beyond, IC components are becoming more complicated with
More informationInstalling the Cisco 2524 and Cisco 2525 Routers
CHAPTER 3 Installing the Cisco 2524 and Cisco 2525 Routers This chapter guides you through the installation of the Cisco 2524 and Cisco 2525 routers and includes the following sections: Required Tools
More informationSPM Series. Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationuclamp2512t Lightning and ESD Protection for Gigabit Ethernet Interfaces PROTECTION PRODUCTS - MicroClamp Description Features
- MicroClamp Description The μclamp 5T TVS diode is specifically designed to meet the performance requirements of Gigabit Ethernet interfaces. They are designed to protect sensitive PHY chips from damage
More informationfor Facilitywide Protection Immediate shipment! Featuring 25kA, 50kA, 80kA and 100kA models
Surge Suppression Systems for Facilitywide Protection Immediate shipment! Featuring 25kA, 50kA, 80kA and 100kA models Protects facilities and equipment against catastrophic lightning strikes and internally
More informationLiebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System
Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe
More informationfor Facilitywide Protection Immediate shipment! Featuring 25kA, 50kA, 80kA and 100kA models
Surge Suppression Systems for Facilitywide Protection Immediate shipment! Featuring 25kA, 50kA, 80kA and 100kA models Protects facilities and equipment against catastrophic lightning strikes and internally
More informationPlugstrip and Wallmount Surge Protectors
Plugstrip and Wallmount Surge Protectors SP410A SP411A SP412A SP413A SP414A MAY 1998 SP415A SP416A SP417A SP418A SP419A Protected Wiring TEL/MODEM IN OUT Power OUT IN CUSTOMER SUPPORT INFORMATION To order
More informationInstalling the Cisco AS5400XM Universal Gateway
CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,
More informationMDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester
These modular distribution panel protectors for three phase power systems are designed to prevent damage to electrical distribution systems from mainsborne transient voltages which can occur as the result
More information3M ID 3000 System. ID 3128 block. Disconnection module. ID 3100 block Wire guide housing
3M ID 3000 System ID 3128 block Disconnection module ID 3100 block Wire guide housing 71 Disconnection element 72 The ID 3000 connection system is the latest generation of insulation displacement connector
More information2U Congestion Alert Rack Insert for UK
2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,
More informationQuickNetwork QND200 Distribution Panel
QuickNetwork QND200 Distribution Panel Installation Guide CSQND200V1 10/04 Rev. A Before You Get Started This manual is designed to provide an overview of the installation process and guidelines for installing
More informationwith its cables, connectors, Switches, Hubs and topologies
Introduction to LAN www.mycsvtunotes.in with its cables, connectors, Switches, Hubs and topologies LAN Small interconnected computers or workstations within a building or small area up to 10 Kms. Small
More informationProtect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection
Protect It! 8-Outlet A/V Surge Protector, 10-ft. Cord, 3240 Joules, Tel/Modem/Coax Protection MODEL NUMBER: AV810 Highlights 8 outlets / 10-ft. cord with space saving right angle plug 3240 joule rating
More informationSPECIAL SPECIFICATION 1864 Pole Mounted Cabinet
1993 Specifications CSJ s 0924-06-221,etc. & 0924-06-223 SPECIAL SPECIFICATION 1864 Pole Mounted Cabinet 1. Description. This specification describes the minimum acceptable requirements for a weatherproof
More informationSemiconductor Protection Devices
Semiconductor Protection Devices General and Specific Len Stencel, Applications Manager 1 Two General Types of Semiconductor Protection Devices Shunting (shorting) Limits Voltage (Crowbar or Clamp) Parallel
More informationSPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System
2004 Specifications CSJ 0902-48-433 SPECIAL SPECIFICATION 6322 Digital Video Encoder/Decoder (Ethernet) System 1. Description. Furnish and install Digital Video Encoder/Decoder (Ethernet) System (DVE/DES)
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationInstallation Instructions
Installation Instructions (1771-ODD Series B) Use this document as a guide when installing the catalog number 1771-ODD series B output module. The ac isolated output module is shipped in static-shielded
More informationReliability in Surge Protection. Surge Protection. AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes.
Reliability in Surge Protection Surge Protection AC & DC Power Photovoltaic Coaxial Telecom Gas Discharge Tubes www.citel.us CITEL Established in 1937, CITEL is the global leader in the development and
More informationLow Capacitance Bidirectional Single Line TVS Protection Diode UM5080T DFN
General Description UM5080T Low Capacitance Bidirectional Single Line TVS Protection Diode UM5080T DFN2 1.0 0.6 The UM5080T TVS protection diode is designed to replace multilayer varistors (MLVs) in portable
More informationProtect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11
Protect It! 7-Outlet Surge Protector, 6-ft. Cord, 1080 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER6TEL Highlights 7 outlets / 6-ft. cord 1080 joule rating Modem/fax surge protection $50,000
More informationRClamp0551P. Ultra-Low Capacitance 1-Line, 5V ESD protection. PRELIMINARY Features. PROTECTION PRODUCTS - RailClamp Description
- RailClamp Description RailClamp TS arrays are ultra low capacitance ESD protection devices designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive
More informationPreparing to Install the Cisco AS5350XM Universal Gateway
CHAPTER 2 Preparing to Install the Cisco AS5350XM Universal Gateway This chapter describes the tasks you must perform before you begin to install the Cisco AS5350XM universal gateway and includes the following
More informationELPROMA NTSprotect Surge Protection
ELPROMA NTSprotect Surge Protection Rack 19 back panel with NTS-protect As the antenna is roof mounted (to have a clear view of the sky) it is likely to be exposed to lightning strikes. Protection against
More informationRClamp3374N. High Power TVS for Ethernet Interfaces. PRELIMINARY Features
PROTECTION PRODUCTS - RailClamp Description RailClamp TS diodes are specifically designed to protect sensitive components which are connected to high-speed data and transmission lines from overvoltage
More informationUSER MANUAL MODEL 503P & 503PC. Parallel Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 503P & 503PC Parallel Surge Protectors C E R T I F I E D An ISO-9001 Certified Company Part# 07M503P-C Doc# 074201U Rev. D Revised 1/21/08 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT
More informationProtect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11
Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER7TEL Highlights 7 outlets / 7-ft. cord 2520 joule rating Modem/fax surge protection $75,000
More informationLCDA15C-6. Low Capacitance TVS Diode Array For Multi-mode Tranciever Protection. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics
Description The LCDA15C6 has been specifically designed to protect sensitive components which are connected to data and transmission lines from over voltages caused by electrostatic discharge (ESD), electrical
More informationInstalling the Cisco VG224 Voice Gateway
CHAPTER 3 This chapter contains the procedures for installing your Cisco VG224 voice gateway and consists of the following sections: Safety Recommendations, page 3-2 Site Log, page 3-3 Keeping Track Checklist,
More informationQuickNetwork QND300 Distribution Panel
QuickNetwork QND300 Distribution Panel Installation Guide CSQND300V1 10/04 Rev. A Before You Get Started This manual is designed to provide an overview of the installation process and guidelines for installing
More informationLiebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi
Liebert TVSS: The First Line of Defense - Product Overview Jim Tiesi INTERCEPTOR SURGE SUPPRESSION Overall Design True modular design Low impedance copper conduction plates Best in class performance Real-time
More informationInnovative Technology TVSS Products
Innovative Technology TVSS Products Technical Document WHY SILICON AVALANCHE DIODES ARE NOT RECOMMENDED FOR AC POWERLINE SUPPRESSORS TD37H12ASE Effective Date: 4/05 Page 1 WHY SILICON AVALANCHE DIODES
More informationDistribution Devices - Outlets, Jacks, & Plates
35564W Modular Tel Jack 4con Eaton Wiring Devices Catalog Number 35564W Manufacturer Eaton Wiring Devices Description Telephone Jack, Modular Jack; White; Thermoplastic; 4 Wire RJ11/RJ14; Category 3; Surface
More informationUESD6V8L1F. Low Capacitance Single Line ESD Protection Diode Array UESD6V8L1F DFN General Description
Low Capacitance Single Line ESD Protection Diode Array DFN2 1.0 0.6 General Description The ESD protection diode is designed to replace multilayer varistors (MLVs) in portable applications such as cell
More informationCVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-200-KIT 200 V Bias Tee Kit Description The CVU-200-KIT Bias Tee Kit consists of three 2600-RBT-200
More informationMICHIGAN DEPARTMENT OF TRANSPORTATION
MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13
More informationSurge Protection Products for the small office/home office and professional grade
Surge Protection Products for the small office/home office and professional grade With the increasing reliance on Computer and other microprocessor based equipment - the importance of protecting data and
More informationRClamp0501T. Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics.
- RailClamp Description RailClamp TS arrays are ultra low capacitance ESD protection devices designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive
More informationApplication Note. Table 1. Test requirements by equipment type
UL1459 and FCC Part 68 Requirements Application Note Problem/Solution Subscriber equipment, also known as customer premise equipment (CPE), includes any equipment that is connected to the telecommunications
More informationInstalling the Cisco ATA
CHAPTER 2 This section provides instructions for installing the Cisco ATA 186 and Cisco ATA 188. Before you perform the installation, be sure you have met the following prerequisites: Planned the network
More informationForm C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty
DIN RAIL MOUNTED ACTIVE TRACKING FILTERS WITH SURGE PROTECTION maximize protection STFE Elite Series Active tracking filter with surge protection Features Series connected DIN Rail mounted filter Patented
More informationForm C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty
DIN RAIL MOUNTED ACTIVE TRACKING FILTERS WITH SURGE PROTECTION maximize protection STFE Elite Series Active tracking filter with surge protection Features Series connected DIN Rail mounted filter Patented
More informationIsobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal
Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Tel/Fax/Modem, Metal MODEL NUMBER: ISOTEL4ULTRA Highlights 4 NEMA 5-15R outlets in exclusive isolated filter
More informationRClamp0504F RailClamp Low Capacitance TVS Array
- RailClamp Description RailClamps are surge rated diode arrays designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive components which are connected
More informationThis is not the International Symbol for Surge Protection... But it should be!
This is not the International Symbol for Surge Protection... But it should be! One DITEK Center 1720 Starkey Road Largo, FL 33771 1-800-753-2345 www.ditekcorp.com 191126 Rev1 CCTV - HEAD END PROTECTION
More informationSMDA05C-7 THRU SMDA24C-7
Description The SMDAxxC-7 series of transient voltage suppressors are designed to protect components which are connected to data and transmission lines from voltage surges caused by electrostatic discharge
More informationFeatures. Applications
- MicroClamp Description The µclamp TM series of TVS arrays are designed to protect sensitive electronics from damage or latch-up due to ESD. It is designed to replace multilayer varistors (MLVs) in portable
More informationType DH7091 Transient Protection Assembly
Type DH7091 Transient Protection Assembly D3P00801102 Installation Manual PN4.10:DH7091 Revision A June 1991 This manual supersedes the previous issue dated February 1990. In October 2001, company logos
More informationRClamp0504FA RailClamp Low Capacitance TVS Array
- RailClamp Description RailClamp low capacitance TVS array designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive components which are connected
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationUM5075/5079 Single Line ESD Protection Diode Array UM5075 SOD523 UM5079 DFN General Description Applications Features
General Description Single Line ESD Protection Diode Array UM5075 SOD523 UM5079 DFN2 1.0 0.6 The ESD protection diode is designed to replace multilayer varistors (MLVs) in portable applications such as
More informationEMOSAFE EN-100 Network Isolators for PCB assembly
ENGLISH EMOSAFE EN-100 Network Isolators for PCB assembly Product Datasheet 1 FEATURES AND ADVANTAGES Suitable for PCB assembly: pluggable or solderable Ultra-compact Conforms to IEC 60601-1 10/100/1000
More informationInstruction Manual IM E Table of Contents
Instruction Manual IM01005031E Effective For Mounting External To Table of Contents 1.0 Introduction 2.0 Installation 3.0 Operating Features 4.0 Troubleshooting 5.0 Specifications 6.0 Ordering Guidelines
More informationSOHO Access TM Module. User Guide. SAM-SW5U: 5-port 10/100 Ethernet Switch
SAM-SW5U: 5-port 10/100 Ethernet Switch 1. Introduction The 5 port 10/100BASE-TX Switch is compact and attractively designed for use within Suttle s SOHO Access TM Enclosure. They are ideal solution for
More informationInstruction Manual: IM E
Innovative Technology TVSS Products The I.T. Equalizer Installation Instruction Manual: IM01005011E Rev. 2 May 2009 Contents Page 1 Introduction... 1 1.1 Scope... 1 1.2 I.T. Equalizer Catalog Numbering
More informationITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T
Online Coaxial / Twisted Pair Surge Protection Device ITEM NO: SP-001, SP-001P, SP-001VP, SP-001VPD, SP-002, SP-002VP, SP-002VPD, SP-003, SP-004, SP-004VPD, SP-005, SP-006, SP-016C, SP-016T Application
More informationA Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks
The Network of Networks 3M High Density Cross-Connect Modules STG2000 Series The 3M High Density Cross-Connect Modules STG2000 Series are IDC copper cross-connects that can be used in a wide variety of
More informationCVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-3K-KIT 3 kv Bias Tee Kit Description The CVU-3K-KIT Bias Tee Kit consists of three bias tees for
More informationBourns Electronic Current Limiters
Bourns Electronic Current Limiters TCS & TBU High-Speed Protectors Short Form Brochure Bourns TCS HSP Product Overview Basic TCS HSP Device Operation The Bourns TCS DL Series High-Speed Protector (HSP)
More informationRugged MediaConverter
Rugged MediaConverter Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, Ontario Canada L4L 7Z4 Web: http://www.ruggedcom.com/ Tel: (905) 856-5288 Fax: (905) 856-1995 Toll Free: (888) 264-0006
More informationRClamp0504PA RailClamp Low Capacitance TVS Array
- RailClamp Description RailClamp TVS diodes are specifically designed to protect sensitive components which are connected to high-speed data and transmission lines from overvoltage caused by ESD (electrostatic
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationexp-s1110pe PoE+ Gigabit Ethernet Extenders
perle.com https://www.perle.com/products/10-100-1000-poe+-ethernet-extender.shtml exp-s1110pe PoE+ Gigabit Ethernet Extenders 10/100/1000 PoE+ Ethernet Copper Extenders Extends 10/100/1000Base-T up to
More informationhttp://newage-energy.net Table of Contents 3 1995-2003 & 1998-2007 world lightning maps 4 2006 & 2008 RSA Lightning maps 5 2011 world lightning map 6-11 Applications 12 Under/Over voltage switch 13 Plugtops
More informationSystems which use a conventional POTS subscriber line to dial a compatible system and transfer digital data.
PSTN Protection The demand for voice and data communications has never been greater. Today, virtually everyone in the developed world has access to a land-line telephone, which carries their voice or data
More information2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning
.1 Industrial and Commercial Surge Protection Introduction Industrial and Commercial Surge Protection SPD Series for Integration into Electrical Distribution Equipment SPD Series for Mounting External
More informationSPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment
1993 Specifications CSJ 0043-09-104, etc. SPECIAL SPECIFICATION 1606 ISDN Compressed Video Equipment 1. Description. This Item shall govern for the furnishing and installation of Integrated Services Digital
More informationRClamp0521PA. Ultra-Low Capacitance 1-Line ESD protection. PROTECTION PRODUCTS - RailClamp Description. Features. Mechanical Characteristics
- RailClamp Description RailClamp TS arrays are ultra low capacitance ESD protection devices designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive
More informationModel 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2600B-PM-1 200 V Protection Module with 1 A Clamp Description The Model 2600B-PM-1 200 V Protection
More informationRClamp0504S RailClamp Low Capacitance TVS Array
- RailClamp Description RailClamps are surge rated diode arrays designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive components which are connected
More informationPhysical Layer V What does the physical layer provide?
SEMESTER 1 Chapter 8 Physical Layer V 4.0 90 Points 8.1.1 What does the physical layer provide? What are the four elements of delivering frames across the media? 8.1.2 What are the three basic forms of
More information4-W HDSL/56Kbps Isolation Card With 130/190V Span Powering. Description & Installation P30140
4-W HDSL/56Kbps Isolation Card With 130/190V Span Powering Description & Installation P30140 Printed in USA 11/12 TO506 Rev. A Table of Contents 1.0 PRODUCT SCOPE 3 2.0 PRODUCT OVERVIEW 3 2.1 System Requirements
More informationSPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment
1993 Specifications CSJ s 0912-34-101 & 0027-08-108, etc. SPECIAL SPECIFICATION 1672 ISDN Compressed Video Equipment 1. Description. Furnish and install Integrated Services Digital Network (ISDN) Compressed
More informationAironet and WLAN Controller Product Power Options
Aironet and WLAN Controller Product Power Options Document ID: 21480 Contents Introduction Prerequisites Requirements Components Used Conventions Cisco Discovery Protocol Power Options Aironet 350 Series
More informationRClamp0502A RailClamp Low Capacitance TVS Array
- RailClamp Description The RailClamp series consists of ultra low capacitance TS arrays designed to protect high speed data interfaces. This series has been specifically designed to protect sensitive
More information