UNLOCK YOUR IEC TESTING EXCELLENCE

Size: px
Start display at page:

Download "UNLOCK YOUR IEC TESTING EXCELLENCE"

Transcription

1 IMPROVE EFFICIENCY TEST WITH CONFIDENCE OF KNOWING HOW LEARN AND EXPAND YOUR IEC SKILLS MASTER YOUR NETWORK KNOWLEDGE GENERATE TEST RESULTS UNLOCK YOUR IEC TESTING EXCELLENCE Connect To & Read From Live IEDs Monitor Reports & Operate Controls Analyze & Troubleshoot Communication Profiles Simulate MMS Server IEDs & Their GOOSE definitions Monitor, Visualize & Generate Process Bus Sampled Values Create Complex Test Scenarios & Reuse Them When Needed Test Network Impact to Your Protection & Automation Functions Measure System Performances Perform Tests Under Abnormal or Avalanche Conditions

2 2016 Grid Software Inc. All rights reserved.

3 HOW DO YOU BENEFIT FROM USING GOOSEAIR? IMPROVE EFFICIENCY Setup IEC Test scenarios in a few steps. No need to perform complex configuration procedures, or set unknown parameters. The time to simulate GOOSE, MMS Server or Process Bus data is measured in clicks. Simply connect to Live IEDs or import SCL files, and in no time you will see resulting data. Equipped with internal storage, gooseair will allow you to save & reuse your customized test scenarios, or compatible IEC IEDs previously recorded on your Local Area Network. TEST WITH CONFIDENCE KNOW-HOW With gooseair there are no unknowns! Monitoring functions support all IEC Communication profiles including: MMS Client/Server, GOOSE Publisher/Subscriber and Process Bus Sampled Values. Don t worry if you have never worked with some of these profiles before! The data is presented in an easy to understand way, with stripped of IEC object models content understandable to everyone. After you spend some time working with gooseair, you will truly call yourself an IEC expert! REDUCE INVESTMENT ON TEST EQUIPMENT gooseair will replace IEC compatible IEDs missing in your LAB or your FAT setup. You will be able to simulate 64 of SCL based IED definitions simultaneously, and any of the IEC communication profiles you may require. gooseair simulates Client/Server MMS, GOOSE and Process Bus Sampled Values. And that s not all: if you wonder how your IEDs or the system would perform under real network conditions, use gooseair s unique Network Tools to simulate increased network traffic, abnormal or avalanche conditions. Measurement of Network delays on critical routes which impact your Protection functions is another feature of the gooseair Network Tools. LEARN AND IMPROVE YOUR IEC SKILLS gooseair users are given access to Grid Software IEC Online Training Center always accessible to expand your technical knowledge. The help system composed of HTML Help and Video Lessons will describe gooseair features in detail and step by step using working examples. With support for all communication profiles, gooseair will demonstrate through live examples how principles, models and services of the IEC work in reality. MASTER YOUR NETWORK KNOWLEDGE Understand how different network designs may impact your system by measuring corresponding performances. Measure network delays with gooseair Sender/Receiver feature, or learn how increased & avalanche traffic conditions impact your network and systems performances. High availability network protocols PRP/HSR are explained in detail with gooseair Network Redundancy Analyzer. Using these or other features, part of gooseair Network Tools will increase your understanding of the network design, help you in parsing of the IEC communication profiles and improve your overall understanding of Protection and Control systems. GridSoftware gooseair 03

4 WHAT IS INCLUDED IN GOOSEAIR? 1 GOOSEAIR PC A Linux based Hardened Computer, fully pre-configured and ready to use. You can choose from one of the two gooseair PC platforms: Intel Atom 1.6GHz/4Gb RAM/8Gb Compact Flash 2 SFP/ 5 GbE (1000Base-T) Ports /2USB/COM Redundant 12-48VDC Intel Core i7 (Chipset 3517UE) / 8Gb DDRAM / 16 to 500 Gb Industrial Compact Flash 8x GbE (1000Base-T) Ports /2USB/10x COM/VGA Universal Dual Power Supply: VAC / VDC 2 GOOSEAIR WINDOWS PROGRAM to be installed on your computer a license free installation program is available at: 3 IRIG-B/1PPS INPUT CARD (OPTIONAL) You can extend PTP and SNTP Time Synch features of gooseair by adding this IRIG-B/1PPS card (especially important if gooseair is intended to work as a Merging Unit simulator). 04 GridSoftware gooseair

5 HOW DO YOU SETUP GOOSEAIR? STEP 1 Install gooseair Windows program on your PC. STEP 3 Connect your gooseair to Process Bus (if available). STEP 2 Connect gooseair PC to the same Local Area Network (LAN) with your Protection Relays, GW or HMI. Connect your PC to the same LAN or to gooseair directly. STEP 4 Start using gooseair features available on your gooseair Windows program interfaces. STATION BUS PRP Networks PROCESS BUS Protection Relays Linux OS merging unit gooseair PC KEY FEATURES AND ADVANTAGES: gooseair is designed to help you in all aspects of the IEC engineering processes including: Easy understanding of IED s Model capabilities (IEC or IEC ) Project & IED content analysis of Ed1/Ed2 SCL models including: SCD/IID/CID/ICD files Testing of live Server IEDs (MMS Reports, Control Operation, GOOSE, Process Bus) Connecting & Monitoring of Process Bus Sampled Values (Amps, Volts, W, VAR, PF) Visual presentation of Currents & Voltages received over Process Bus MMS Simulation of Server IEDs using their configuration files Simulation of GOOSE Messages Simulation of Process Bus Sampled Values PRP/HSR analyses Creating various Test Scenarios using Logic editor and built in logic engine GridSoftware gooseair 05

6 1. BROWSE AND EDIT SCL FILES EXPLORE Explore IEC Models by importing.icd,.cid. or.scd files. gooseair provides dedicated windows to efficiently present SCL object tree, its Model Properties and initial values. Predefined Filter options ensure easy and intuitive ways of navigating through the SCL objects. CREATE OR MODIFY SCL MODELS Create new or modify existing IEDs SCL configuration files by changing or adding data set members, creating report goose or sampled values control blocks. Use these models for simulation, testing or troubleshooting purposes. gooseair SCL builder is intelligent. SCL objects become available on the Ribbon menu only when allowed to be added. 2. CLIENT SERVICES DISCOVER IED MODELS & READ VALUES Using Client/Server MMS communication, connect to multiple IEDs simultaneously to discover their object models, configuration parameters or current values. You can auto read all values at the same time, read entire LN or simply individual values only. MMS REPORTING Report Controller option will quickly allocate buffered and unbuffered report control blocks belonging to an IED model. From there, you can easily Configure, Initiate & Enable reports on remote IEDs. Received MMS Reports with their values will be displayed on specially designed presentation windows. 06 GridSoftware gooseair

7 MMS REPORTING Report Controller option will quickly allocate buffered and unbuffered report control blocks belonging to an IED model. From there, you can easily Configure, Initiate & Enable reports on remote IEDs. Received MMS Reports with their values will be displayed on specially designed presentation windows. WRITE VALUES & OPERATE CONTROLS Set writeable and configurable parameters or Operate controls of any types. gooseair will recognize control mode values and will auto adjust control screens to allow input of all required control parameters SIMULATIONS MMS SERVER Based on imported SCL files (.icd/.cid/.scd), gooseair will concurrently simulate up to 64 different MMS Server IEDs. IEDs created by gooseair SCL Builder, or the ones saved using connect & discovery features from previous live sessions, will also be simulated by gooseair MMS Server simulation services. Once in simulation mode, gooseair will provide means to allow Value Forcing or MMS Report triggering. GridSoftware gooseair 07

8 GOOSE SIMULATIONS Simulating of GOOSE definitions is extremely simplified. No need to browse & search through the model, as gooseair automatically groups all GOOSE Control Blocks and associated DataSets. Changing DataSet values is easy - windows are designed to read current or accept new values that will instantly trigger new GOOSE messages. 4. MONITORING FUNCTIONS GOOSE AND REPORT MONITOR Observe system GOOSE messages with GOOSE Monitor Windows designed to present all relevant information, values and time compared results. Filters and labels provided on these screens will simplify a search for relevant information, while Value Tabs will extract values from the GOOSE DataSet members for a quick access. The MMS Report monitoring windows will capture any Buffered or Unbuffered reports providing insights to triggers (cause of report transmissions) or inclusion bitstring (reported data) values. Spy tool will focus on changes of specific model values, while Event monitors will focus on displaying new values only. 08 GridSoftware gooseair

9 PACKET INSPECTOR Regardless of the type of captured and presented messages, gooseair s Packet Inspector will decode received packets in user understandable format. The original octet format of the messages will also be preserved and presented for data integrity purposes. The Packet Inspector window will simplify message troubleshooting to the point where you do not have to be a communication expert to understand content of the GOOSE Publisher/Subscriber or Client/Server MMS communication profiles. SUPPORT FOR PCAP FILE For those users relying on Wireshark, gooseair now provides support for.pcap files. You can use gooseair to record and save Ethernet traffic in industry well-known network monitoring format. Saved files can later be opened and analyzed using Wireshark tools. 5. PROCESS BUS SAMPLED VALUES (SV) SV MONITOR Attach gooseair to a process bus with a merging unit or any other device distributing SV streams, and monitor live SV traffic using table views or sinusoidal graph presentations. Record SV stream sequences and present them using graphical viewer. GridSoftware gooseair 09

10 SV GENERATOR AND STATE SEQUENCER Configure control block parameters of SV streams and define amplitudes and phase angles of currents and voltages. Use built in State Sequencer to define duration of SV stream sequences with different input and output parameters. The SV State Sequencer will accept triggers including system GOOSE messages to trigger a change of simulated sequences. Once defined & started, the Sequencer will start generating SV streams back to the Process Bus network. 10 GridSoftware gooseair

11 6. CUSTOM LOGIC FUNCTIONAL BLOCK DIAGRAM Use gooseair s Function Block Diagram editor to create custom logic and perform customized test setups. Functional block diagram is equipped with a large number of functions, timers, operators and operands allowing you to create logic of any complexity. The logic programs can be interconnected with your GOOSE publishing or subscribing messages. They can be saved and reused for different test purposes. Being event driven, the fast Logic Engine will execute programs below the time performances proposed by the IEC Standards. PROGRAM MONITOR The logic program editor, called Database Snapshot, will assist you in monitoring and analyzing interim or final results of your custom logic programs. With the Database snapshot, you can change program values, thus influencing the results - and get necessary confidence that your program behaves the way you designed it. GridSoftware gooseair 11

12 7. PRP DRIVER AND NETWORK REDUNDANCY ANALYZER (NRA) gooseair fully supports the IEC (Clause 4, Ed2) standards: parallel redundancy protocol (PRP). Built in kernel space, the PRP driver enables gooseair to act as a Dual Attached Node PRP (DANP) on PRP networks. Network Redundancy Analyzer (NRA) services, part of the gooseair core load, will perform monitoring and analyses of both PRP & HSR based communications, with optional ability to filter Supervision frames only. Simply connect gooseair to PRP or HSR networks, and NRA customized screens will present analyses of the redundancy packets for you. 8. NETWORK TOOLS NETWORK PERFORMANCE TESTING Performance of your distributed or networked solutions can largely be influenced by the design of the Network. Measurement of the network delays for Utility based Automation systems, something that traditionally has not been required, is now crucial in understanding whether the Network design, network configuration settings, or selected network equipment, serve your systems the way you expect. gooseair Network Tools (Sender/ Receiver) will calculate network delay time between any two points on your network, thus measure influence of the network on the performance of your critical applications. In these performance tests, gooseair will not use PING or similar test packet formats, but intended communication protocol profiles (i.e. GOOSE). 12 GridSoftware gooseair

13 TRAFFIC GENERATOR Testing your applications connected to a LAB test network will likely show better results comparing to results from the production network. In your LAB environment, the Switches are dealing with a low traffic volume, while in reality they have to process traffic with large volume of packets. gooseair Traffic Generator will enable you create increased traffic volumes, abnormal or even avalanche conditions. Error and Network Loss generators will further help you in generating erroneous traffic or traffic with intentional loses. Such conditions will allow you monitor behavior & performance of your application algorithms using various what if scenarios. GridSoftware gooseair 13

14 TECHNICAL FEATURES Edition 1 & Edition 2 Support IEC61850 & IEC GOOSE Publisher MMS Client Process Bus Simulator SCL Viewer and Editor Data Property Analyzer Buffered & UnBuffered Reports SNTP/PTP/IRIG-B Time Synch Network Performance Measurements GOOSE Subscriber MMS Server Simulator Process Bus Subscriber Operate Controls Read & Write functions IEC Logic Editor & Monitor DANP with HSR/PRP Analyzes Avalanche Generator CONCLUSION gooseair is the most comprehensive IEC test tool on the market. It supports testing of any IEC Communication profiles: MMS Client/Server, GOOSE Publisher/Subscriber, Process Bus. You can connect gooseair to single LAN, PRP redundant or HSR Networks. gooseair Logic Engine will enable design of test cases of any complexity. With the Database Snapshot it will allow you to monitor and troubleshoot the programs. gooseair will calculate the performance of your IEDs and your systems. Network Test Tools will measure the influence of the network and let you observe application behavior under different network conditions. Above all, gooseair s simplicity of use, ensured by intuitive screens, friendly filters and integrated help systems will break the myth that the IEC systems can only be done by communication experts! 14 GridSoftware gooseair

15 ORDER GOOSEAIR NOW Grid Software Inc. 202, A St SE Calgary, AB T2H 1J1, Canada Ph: Belgrade Office: B05 Genex Business Center Vladimira Popovica 6 Belgrade, Serbia Ph:

16 Grid Software Inc. 202, A St SE Calgary, AB T2H 1J1, Canada Ph:

IEDScout. Versatile software tool for working with IEC devices

IEDScout. Versatile software tool for working with IEC devices IEDScout Versatile software tool for working with IEC 61850 devices One software tool for working with all IEC 61850 IEDs Examine IEC 61850 devices IEDScout is an ideal tool for protection and substation

More information

IEC TRAINING PROGRAM

IEC TRAINING PROGRAM IEC 61850 TRAINING PROGRAM A True Hands-On Experience... Ver. 3.1 Date: May, 2014 TRAINING OVERVIEW GridSoftware IEC 61850 Training Program protection and control engineers engaging into the complexity

More information

Overview and Application

Overview and Application IEC 61850 Overview and Application Who am I? Rich Hunt Market Development Leader GE Grid Solutions Over 25 years in the power systems industry At GE for 10 years (almost) Member of IEEE PSRC, U.S. Representative

More information

User guide.

User guide. User guide www.gridsoftware.com Table of Contents SV Analyzer overview...3 1. Getting started...4 1.1. Quick Overview...4 About...4 System requirements...4 Contacts...5 1.2. Installation...6 1.3. License...7

More information

Ethernet Network Redundancy in SCADA and real-time Automation Platforms.

Ethernet Network Redundancy in SCADA and real-time Automation Platforms. Ethernet Network Redundancy in SCADA and real-time Automation Platforms www.copadata.com sales@copadata.com Content 1. ABSTRACT... 2 2. INTRODUCTION... 2 IEC 61850 COMMUNICATION SERVICES... 2 APPLICATION

More information

COMMUNICATION NETWORKS. FOX615/612 TEGO1 IEC GOOSE Proxy Gateway interface module.

COMMUNICATION NETWORKS. FOX615/612 TEGO1 IEC GOOSE Proxy Gateway interface module. COMMUNICATION NETWORKS FOX615/612 TEGO1 IEC 61850 GOOSE Proxy Gateway interface module. 2 FOX615/612 TEGO1 IEC 61850 GOOSE GATEWAY INTERFACE MODULE INTRODUCTION 3 FOX615/612 multiplexing platform. Enabling

More information

Peter Kreutzer, PSSAM/Automation Power World 2011 New Delhi, Secure and reliable Redundant communication network and cyber security

Peter Kreutzer, PSSAM/Automation Power World 2011 New Delhi, Secure and reliable Redundant communication network and cyber security Peter Kreutzer, PSSAM/Automation Power World 2011 New Delhi, 2011-09-20 Secure and reliable Redundant communication network and cyber security Content Reliable Substation communication networks Introduction

More information

TR IEC Deterministic Networking

TR IEC Deterministic Networking INTERNATIONAL ELECTROTECHNICAL COMMISSION TR IEC 61850-90-13 Deterministic Networking Maik Seewald IEC TC57, WG10 maseewal@cisco.com IEC 61850 in a nutshell Title: Communication networks and systems for

More information

User Manual.

User Manual. User Manual www.gridsoftware.com Table of Contents SCL Matrix Overview...4 1. Startup Screen...5 2. Ribbon...7 2.1. Home...8 2.2. Engineering Process...9 2.3. Add...10 2.4. Import/Export...11 3. Projects...12

More information

SUBNET Ultrabox820. Unified Grid Intelligence Platform / MULTI-VENDOR INTEROPERABILITY BY DESIGN

SUBNET Ultrabox820. Unified Grid Intelligence Platform / MULTI-VENDOR INTEROPERABILITY BY DESIGN SUBNET Ultrabox820 Unified Grid Intelligence Platform / MULTI-VENDOR INTEROPERABILITY BY DESIGN Hardware Specifications CHIPSETS IEC 61850 PRP/HSR IRIG-B STORAGE DISPLAY ETHERNET SERIAL - CPU: SUB-820-C7:

More information

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China Real Time Communications Symposium Munich, January 2012 Maciej Goraj maciejgoraj@ruggedcom.com 1 Who is RuggedCom?

More information

COLLABORATE TO WIN. 03/31/2017 Digital Substation Turning IEC61850 features into benefits. Peter Rietmann, Program Manager Digital Substation NA

COLLABORATE TO WIN. 03/31/2017 Digital Substation Turning IEC61850 features into benefits. Peter Rietmann, Program Manager Digital Substation NA COLLABORATE TO WIN 03/31/2017 Digital Substation Turning IEC61850 features into benefits Peter Rietmann, Program Manager Digital Substation NA Increasing Reliability Higher functional integration and process

More information

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA Deploying Digital Substations: Experience with a Digital Substation Pilot in North America Harsh Vardhan, R Ramlachan GE Grid Solutions, USA Wojciech Szela, Edward Gdowik PECO, USA SUMMARY Though IEC 61850

More information

INFO TECH IEC Software Library with testing and simulation tools

INFO TECH IEC Software Library with testing and simulation tools INFO TECH IEC 61850 Software Library with testing and simulation tools Product presentation Prepared by Wojciech E. Kozlowski Version: July 2017 We reserve all rights in this document and in the information

More information

3U 19-inch IEC native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU. Features and Benefits. Certifications

3U 19-inch IEC native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU. Features and Benefits. Certifications DA-820 Series 3U 19-inch IEC 61850 native PRP/HSR computers with Intel Celeron, Core i3 or i7 CPU Features and Benefits IEC 61850-3, IEEE 1613, and IEC 60255 compliant for power substation automation systems

More information

Program. 5 Day IEC Seminar and Training. XXXX Automation & Information Systems XXXX

Program. 5 Day IEC Seminar and Training. XXXX Automation & Information Systems XXXX , 2010 Program 5 Day IEC 61850 Seminar and Training XXXX Automation & Information Systems XXXX 18.-22.01.2010 Notes: 1. Questions and discussions during and after each presentation are expected and welcome.

More information

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software SmartView TM EMS. Polled Network Elements

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software SmartView TM EMS. Polled Network Elements LAN PWR PWR 2 PoE Fault Fiber 00 LAN ON OFF Force Auto 0 00 Half Full LFP Flow Pass SW TX RX Ethernet Media Converter FIBER LAN PWR PWR 2 Fault Fiber 00 LAN ON OFF Force Auto 0 00 Half Full LFP Flow Pass

More information

Experience with a Digital Substation Pilot in North Ame rica

Experience with a Digital Substation Pilot in North Ame rica Experience with a Digital Substation Pilot in North Ame rica Wojciech Szela, Edward Gdowik PECO Harsh Vardhan, R. Ramlachan GE Grid Solutions 2018 Texas A&M Protective Relaying Conference IEC MDS 61850

More information

Advanced Test Equipment Rentals ATEC (2832) DANEO 400. Hybrid Signal Analyzer for Power Utility Automation Systems

Advanced Test Equipment Rentals ATEC (2832) DANEO 400. Hybrid Signal Analyzer for Power Utility Automation Systems Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) DANEO 400 Hybrid Signal Analyzer for Power Utility Automation Systems DANEO 400 analyzing all signals in a substation

More information

Protection and Control IED Manager PCM600 Product Guide

Protection and Control IED Manager PCM600 Product Guide Protection and Control IED Manager Product Guide Protection and Control IED Manager Product version: 2.9 Contents 1. Description... 3 2. Project explorer... 3 3. Parameter setting... 3 4. Graphical application

More information

Providers of a Comprehensive Portfolio of Solutions for Reliable Ethernet and Synchronization in the Energy Market. Industrial

Providers of a Comprehensive Portfolio of Solutions for Reliable Ethernet and Synchronization in the Energy Market. Industrial Industrial Providers of a Comprehensive Portfolio of Solutions for Reliable Ethernet and Synchronization in the Energy Market System-on-Chip engineering The Need for Redundant Data Communications In Automated

More information

Kyland solution for IEEE1588 Precision Time Synchronization in Electric Utilities

Kyland solution for IEEE1588 Precision Time Synchronization in Electric Utilities Kyland solution for IEEE1588 Precision Time Synchronization in Electric Utilities IEEE1588 v2 In measurement and control systems there is often a need to synchronize distributed clocks. Traditionally,

More information

Advantech Industrial Automation Group Cui Lin

Advantech Industrial Automation Group Cui Lin Advantech Industrial Automation Group Cui Lin Target Market Smart Substation Renewable Energy Aluminium Oil & Gas Heavy Industry Petro Chemistry Transportation 2 Global Power Automation Trends Smart Substation

More information

APEX SERVER SOFTWARE NETWORK VIDEO RECORDING SOFTWARE USER MANUAL. Version 1.3

APEX SERVER SOFTWARE NETWORK VIDEO RECORDING SOFTWARE USER MANUAL. Version 1.3 APEX SERVER SOFTWARE NETWORK VIDEO RECORDING SOFTWARE USER MANUAL Version 1.3 OPENEYE Liberty Lake, WA U.S.A. Standard Warranty TABLE OF CONTENTS SERVER SOFTWARE REQUIREMENTS OS REQUIREMENTS VM REQUIREMENTS

More information

Smart Grid Communications. WFCS 2016 May 3-6, 2016, Aveiro, Portugal

Smart Grid Communications. WFCS 2016 May 3-6, 2016, Aveiro, Portugal Smart Grid Communications WFCS 2016 May 3-6, 2016, Aveiro, Portugal Agenda EFACEC Overview Smart Grids Communications Substation Automation System (SAS) Communications Conclusions Efacec is present in

More information

REAL TIME POWER SYSTEMS SIMULATION LABORATORY

REAL TIME POWER SYSTEMS SIMULATION LABORATORY REAL TIME POWER SYSTEMS SIMULATION LABORATORY SHORT DESCRIPTION TABLE OF CONTENTS 1. INTRODUCTION 05 2. REAL TIME POWER SYSTEMS SIMULATORS 05 2.1 OP5600 Simulator 05 2.2 ADPSS Advanced Digital Power

More information

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication GE Grid Solutions DS Agile C264 Dual-bay Modular Substation Controller The DS Agile C264 substation controller is a sophisticated solution supporting multiple applications and functions for substation

More information

Power Automation Solutions with the IEC standard

Power Automation Solutions with the IEC standard Power Automation Solutions with the IEC-61850 standard Advantech Europe B.V. Jash Bansidhar Jash.bansidhar@advantech.nl +31 651 114 715 18 June 2014 Development of the Standard IEC-61850 was developed

More information

What are the issues and challenges during testing (focus on maintenance testing)

What are the issues and challenges during testing (focus on maintenance testing) Secure and Efficient Testing of IEC 61850-Based Protection and Control Systems Agenda What are the issues and challenges during testing (focus on maintenance testing) Requirements for testing IEC 61850-based

More information

6.1. Getting Started Guide

6.1. Getting Started Guide 6.1 Getting Started Guide Netmon Getting Started Guide 2 Contents Contents... 2 Appliance Installation... 3 IP Address Assignment (Optional)... 3 Logging In For the First Time... 5 Initial Setup... 6 License

More information

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin

Multilink. Ethernet Communications for Industrial Automation, Power Utility, and Traffic Control markets. Multilin Multilink Ethernet Communication switches Ethernet for Industrial Automation, Power Utility, and Traffic Control markets Key Benefits The MultiLink family is a line of Industrial and Substation Hardened

More information

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Q.brixx station 101. Base Unit with Test Controller. Most important features: Most important features: Q.brixx base unit consists of side handles, Test Controller Q.brixx station and power supply unit, ready for 14 measurement modules in the same housing and up to 32 plug-in modules

More information

Entergy Development and Deployment of IEC Protection and Control Including Process Bus

Entergy Development and Deployment of IEC Protection and Control Including Process Bus Entergy Development and Deployment of IEC 61850 Protection and Control Including Process Bus Chan Y. Wong Entergy Transmission Eric A. Udren and Solveig Ward Quanta Technology, LLC Presented at CIGRÉ Grid

More information

SmartView EMS. Central EMS. SmartConfig. Fault, Configuration, Accounting, Performance & Security Management (FCAPS)

SmartView EMS. Central EMS. SmartConfig. Fault, Configuration, Accounting, Performance & Security Management (FCAPS) SmartView EMS TM Fault, Configuration, Accounting, Performance & Security Management (FCAPS) Central EMS Expand EMS platform up to 50 SmartViewTM and 25,000 devices management SmartConfig TM Tool for quick

More information

Interconnecting Cisco Network Devices Part 1 v2.0 (ICND 1)

Interconnecting Cisco Network Devices Part 1 v2.0 (ICND 1) Interconnecting Cisco Network Devices Part 1 v2.0 (ICND 1) COURSE OVERVIEW: Interconnecting Cisco Networking Devices, Part 1 (ICND1) v2.0 is a five-day, instructor-led training course that teaches learners

More information

SoCe. Introduction to HSR/PRP/ IEEE 1588(PTP) System-on-Chip engineering V: UCA STICK

SoCe. Introduction to HSR/PRP/ IEEE 1588(PTP) System-on-Chip engineering V: UCA STICK SoCe System-on-Chip engineering Introduction to HSR/PRP/ IEEE 1588(PTP) V:140626 UCA STICK SoCe Index: Introduction: PRP (IEC 62439 3 Clause 4) HSR (IEC 62439 3 Clause 5) IEEE 1588 IEC61588 (PTP) HPS IP:

More information

Communication Networks

Communication Networks Communication Networks Nicholas Honeth (nicholash@ics.kth.se) Contents of the series Lecture 10 - Recap of the networks we ve seen so far - OSI model - Circuit and packet switching - Physical media Lecture

More information

Importance of Interoperability in High Speed Seamless Redundancy (HSR) Communication Networks

Importance of Interoperability in High Speed Seamless Redundancy (HSR) Communication Networks Importance of Interoperability in High Speed Seamless Redundancy (HSR) Communication Networks Richard Harada Product Manager RuggedCom Inc. Introduction Reliable and fault tolerant high speed communication

More information

IEC Comprehensive & Independent Hands-on Training

IEC Comprehensive & Independent Hands-on Training IEC 61850 Comprehensive & Independent Hands-on Training The Future of Power Systems Requires Comprehensive Know-how IEC 61850 is the global standard for Power System Automation (generation, transport,

More information

CASE STUDY. Wind Farm in Mexico Completes First Successful IEC Application With Multivendor Interoperability

CASE STUDY. Wind Farm in Mexico Completes First Successful IEC Application With Multivendor Interoperability CASE STUDY La Venta II Wind Farm Oaxaca, Mexico Wind Farm in Mexico Completes First Successful IEC 61850 Application With Multivendor Interoperability Comisión Federal de Electricidad (CFE) is Mexico s

More information

Preliminary Data Sheet. ANET3910 STANAG3910/ EFEX Test & Simulation Module for Standard Ethernet

Preliminary Data Sheet. ANET3910 STANAG3910/ EFEX Test & Simulation Module for Standard Ethernet Preliminary Data Sheet ANET3910 STANAG3910/ EFEX Test & Simulation Module for Standard Ethernet General Features The ANET3910 is a member of AIM s new line of Ethernet based modules for analysing, simulating,

More information

Jim McGhee, Utility Market Manager, RuggedCom Inc.

Jim McGhee, Utility Market Manager, RuggedCom Inc. First Practical Experience with IEEE 1588 High Precision Time Synchronization in High Voltage Substation with IEC 61850 Process Bus Jim McGhee, Utility Market Manager, RuggedCom Inc. (JimMcGhee@RuggedCom.com)

More information

Wide area networks: packet switching and congestion

Wide area networks: packet switching and congestion Wide area networks: packet switching and congestion Packet switching ATM and Frame Relay Congestion Circuit and Packet Switching Circuit switching designed for voice Resources dedicated to a particular

More information

APEX SERVER SOFTWARE NETWORK VIDEO RECORDING SOFTWARE USER MANUAL. Version 1.7

APEX SERVER SOFTWARE NETWORK VIDEO RECORDING SOFTWARE USER MANUAL. Version 1.7 APEX SERVER SOFTWARE NETWORK VIDEO RECORDING SOFTWARE USER MANUAL Version 1.7 OPENEYE Liberty Lake, WA U.S.A. TABLE OF CONTENTS SERVER SOFTWARE REQUIREMENTS OPERATING SYSTEM (OS) REQUIREMENTS VIRTUAL

More information

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control

Protection, Automation, and Control System. Combine subcycle line protection with complete substation bay control Protection, Automation, and Control System Combine subcycle line protection with complete substation bay control Subcycle distance protection minimizes damage and expensive repairs on transmission lines.

More information

MINER-S Station Controller. Substation Automation

MINER-S Station Controller. Substation Automation Substation Automation MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with

More information

CES2000 Series Industrial Carrier Ethernet Switches

CES2000 Series Industrial Carrier Ethernet Switches Series Industrial Carrier Ethernet Switches Performance Features Supporting IEC61850-3 and IEEE1613 Supporting transmits multicast packets such as packets about IEC 61850 GOOSE or sampling values. Supporting

More information

JULIO OLIVEIRA, ABB POWER GRIDS GRID AUTOMATION, DECEMBER 01 ST ABB Ability - Digital Substations. FISE 7a Edición

JULIO OLIVEIRA, ABB POWER GRIDS GRID AUTOMATION, DECEMBER 01 ST ABB Ability - Digital Substations. FISE 7a Edición JULIO OLIVEIRA, ABB POWER GRIDS GRID AUTOMATION, DECEMBER 01 ST ABB Ability - Digital Substations FISE 7a Edición Current challenges and changes facing utilities Aging infrastructure Legecy systems with

More information

A NEW APPROCH FOR TEST IN SUBSTATION WITH ENTIRE APPLICATION OF IEC INCLUDING THE PROCESS BUS

A NEW APPROCH FOR TEST IN SUBSTATION WITH ENTIRE APPLICATION OF IEC INCLUDING THE PROCESS BUS 108 Study Committee B5 Colloquium August 25-31, 2013 Belo Horizonte, Brazil A NEW APPROCH FOR TEST IN SUBSTATION WITH ENTIRE APPLICATION OF IEC 61850 INCLUDING THE PROCESS BUS *Pereira Junior P. S., Martins

More information

Extended Managed Ethernet Switch - 8 Ports

Extended Managed Ethernet Switch - 8 Ports 11 ConneXium U Product data sheet Extended Managed Ethernet Switch - 8 Ports Description The ConneXium TCSESM-E family of 8 Port Extended Managed Ethernet Switch provides the capabilities of the standard

More information

As for the requirement of having a USB 3.0 port, you will come to know the reason in the next section.

As for the requirement of having a USB 3.0 port, you will come to know the reason in the next section. Network forensics and cybersecurity teams need to have the ability to intercept network traffic and capture data packets in real-time to thwart threats and live attacks. Corporate organisations may set

More information

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks Relion 630 series Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks Integrated load-shedding and protection solution The PML630 is a freely-configurable

More information

GE Grid Solutions. MiCOM S1 Agile. Release Notes. Publication reference: S1Agile/EN RN/I.1

GE Grid Solutions. MiCOM S1 Agile. Release Notes. Publication reference: S1Agile/EN RN/I.1 GE Grid Solutions MiCOM S1 Agile Publication reference: S1Agile/EN RN/I.1 1 MICOM S1 AGILE RELEASE: V1.4.1 v1.4.1 is a new release of the toolsuite used for all current GE Grid Solutions MiCOM P40 Agile

More information

Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO!

Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO! Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO! Abstract Gain a basic understanding of an electrical control management system Exposure to a number of technology

More information

Building Resilient IEC Communication Networks with Next Generation Redundancy Technologies

Building Resilient IEC Communication Networks with Next Generation Redundancy Technologies Building Resilient IEC 61850 Communication Networks with Next Generation Redundancy Technologies Chew Kian Hwee Industrial Application Manager July 2014 2013 Belden Inc. belden.com @BeldenInc Redundancy

More information

IEC Client and Server Simulator

IEC Client and Server Simulator Smart grid management software, ready for the digital utility IEC 61850 Client and Server Simulator Introduction The Xelas Energy 61850 Client and Server simulators are very popular and powerful tools

More information

Protection and Control REX640 Product Presentation

Protection and Control REX640 Product Presentation ABB OY DISTRIBUTION SOLUTIONS Protection and Control REX640 Product Presentation 1MRS758996 A Product introduction Protection and Control REX640 All-in-one protection for any power distribution application

More information

Protection and Control IED Manager PCM600 Product Guide

Protection and Control IED Manager PCM600 Product Guide Product Guide Contents 1. Description...3 2. Project explorer...4 3. Parameter setting...4 4. Graphical application configuration...4 5. Signal matrix...5 6. Graphical display editor...5 7. Hardware configuration...6

More information

irbx6gf Features Intelligent 6 Port HSR/PRP Ethernet Switch IEC and IEEE 1613 Compliant

irbx6gf Features Intelligent 6 Port HSR/PRP Ethernet Switch IEC and IEEE 1613 Compliant irbx6gf www.is5com.com Intelligent 6 Port HSR/PRP Ethernet Switch IEC 61850 and IEEE 1613 Compliant Features Managed Six ports Gigabit Ethernet Switch Fully compliant with IEC 62439-3 HSR High-availability

More information

IEC Test Equipment Requirements

IEC Test Equipment Requirements OMICRON K02 03 20060309 IEC 61850 Test Equipment Requirements Dr. Alexander Apostolov K02 03 20060309 Page: 1 Intelligent Substation Automation Systems OMICRON K02 03 20060309 Page: 2 Intelligent Sensor

More information

GE Multilin 350 Feeder Protection Relay Specifications

GE Multilin 350 Feeder Protection Relay Specifications GE Multilin 350 Feeder Protection Relay Specifications The feeder protection relay shall provide primary protection of medium voltage distribution feeders. The relay shall be equipped with the following

More information

DRAFT. Dual Time Scale in Factory & Energy Automation. White Paper about Industrial Time Synchronization. (IEEE 802.

DRAFT. Dual Time Scale in Factory & Energy Automation. White Paper about Industrial Time Synchronization. (IEEE 802. SIEMENS AG 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 DRAFT Dual Time Scale in Factory & Energy Automation White Paper about Industrial

More information

Trends, Lessons and Benchmarks

Trends, Lessons and Benchmarks Trends, Lessons and Benchmarks Dr. Alexander Apostolov Disclaimer: The person making this presentation is not responsible for what he says because he has no clue what he is talking about Questions What

More information

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series Substation Automation Products Generator protection REG670/650 Relion 670 and 650 series A new protection standard for your valuable assets Based on ABB s extensive experience, REG670 and REG650 IEDs (Intelligent

More information

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations siemens.com/siprotec5 SIPROTEC 5 Table of content Introduction New functions of V7.8 SIPROTEC 5 - the core of Digital Substation

More information

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

FITNESS GB s Pilot Multi-Vendor Digital Substation - Architecture and Design Philosophy

FITNESS GB s Pilot Multi-Vendor Digital Substation - Architecture and Design Philosophy FITNESS GB s Pilot Multi-Vendor Digital Substation - Architecture and Design Philosophy C. Patterson *, P. Mohapatra *, C. Fundulea * C. Popescu-Cirstucescu G. Lloyd, P. Newman * SP Energy Networks, UK,

More information

RTDS Training course

RTDS Training course RTDS Training course Intelligent Electrical Power Grids, TU Delft Overview of RTDS Hardware and RSCAD COORDINATOR: DR. IR. J.L. RUEDA TORRES RESPONSIBLE FOR LAB INSTRUCTIONS: RISHABH BHANDIA 1. INTRODUCTION

More information

Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600

Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600 Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600 Contents COM600 Product Overview Business Overview Product News Overview June 12-14, 2012 Slide

More information

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch

SEL-2730M. Reliably Control and Monitor Your Substation and Plant Networks. Managed 24-Port Ethernet Switch SEL-2730M Managed 24-Port Ethernet Switch Reliably Control and Monitor Your Substation and Plant Networks Features and Benefits Tough Designed, built, and tested for trouble-free operation in extreme conditions,

More information

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series Substation Automation Products High impedance differential busbar protection REB650 Relion 650 series One IED for a wide range of high impedance differential protection applications ABB introduces a new,

More information

Designing Non-Deterministic PAC Systems to Meet Deterministic Requirements

Designing Non-Deterministic PAC Systems to Meet Deterministic Requirements Designing Non-Deterministic PAC Systems to Meet Deterministic Requirements 1 Abstract. This paper presents the results of the design and performance testing of a complete PAC system for a 230/115 kv generation

More information

Test Universe 3.10 Module: IEC Client/Server. Efficient and reliable protection testing in IEC Substation Automation Systems

Test Universe 3.10 Module: IEC Client/Server. Efficient and reliable protection testing in IEC Substation Automation Systems Test Universe 3.10 Module: IEC 61850 Client/Server Efficient and reliable protection testing in IEC 61850 Substation Automation Systems Content 1. Introduction 3 2. Access and set IEDs automatically 4

More information

Simplify System Complexity

Simplify System Complexity 1 2 Simplify System Complexity With the new high-performance CompactRIO controller Arun Veeramani Senior Program Manager National Instruments NI CompactRIO The Worlds Only Software Designed Controller

More information

ForneyLink TM Touchscreen User Interface

ForneyLink TM Touchscreen User Interface ForneyLink TM Touchscreen User Interface Digital Readout with Full Data Acquisition Digital Readout ForneyLink TM is an intuitive, comprehensive, digital display of significant, relevant material testing

More information

Migration Paths for IEC Substation Communication Networks Towards Superb Redundancy Based on Hybrid PRP and HSR Topologies

Migration Paths for IEC Substation Communication Networks Towards Superb Redundancy Based on Hybrid PRP and HSR Topologies Transmission & Distribution SMART GRIDS ASIA 2013 Migration Paths for IEC 61850 Substation Communication Networks Towards Superb Redundancy Based on Hybrid PRP and HSR Topologies siemens.com/answers Table

More information

Communication in Substations with IEC Simple Communication Test with IEC Johannes Bruss, Siemens AG, E D EA PRO LM Siemens AG 2008

Communication in Substations with IEC Simple Communication Test with IEC Johannes Bruss, Siemens AG, E D EA PRO LM Siemens AG 2008 Communication in Substations with IEC 61850 Simple Communication Test with IEC61850 Johannes Bruss, Siemens AG, E D EA PRO LM As a first example, it has to be checked in a simple way that the communication

More information

Chapter 16: Switched Ethernet in Automation. Wenbo Qiao

Chapter 16: Switched Ethernet in Automation. Wenbo Qiao Chapter 16: Switched Ethernet in Automation Wenbo Qiao Ethernet Basics What is Ethernet? Why Ethernet? ( not FieldBus?) Flexibility, Scalability and Performance Key Strength: many protocols running simultaneously

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CMC 850 The Protection Test Set Dedicated to IEC 61850 CMC 850: Protection Testing with Sampled Values The CMC 850 is

More information

1-Port Gigabit Ethernet Network Card - PCI Express, Intel I210 NIC

1-Port Gigabit Ethernet Network Card - PCI Express, Intel I210 NIC 1-Port Gigabit Ethernet Network Card - PCI Express, Intel I210 NIC Product ID: ST1000SPEXI Boost the performance and capabilities of your server or desktop computer by adding a Gigabit Ethernet port through

More information

JetNet 6528Gf. Features. Industrial 28G Full Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH

JetNet 6528Gf. Features. Industrial 28G Full Gigabit Managed Ethernet Switch INDUSTRIAL ETHERNET RACKMOUNT SWITCH INDUSTRIAL ETHERNET RACKMOUNT SWITCH Industrial 28G Full Gigabit Managed Ethernet Switch JetNet 6528Gf The JetNet 6528Gf series is a 19-inch Full Gigabit Layer 2+ Industrial switch and is specially designed

More information

Specifications. Substation Automation System Test Bed (SASTB)

Specifications. Substation Automation System Test Bed (SASTB) Specifications Substation Automation System Test Bed (SASTB) Please see the details of the Pre-Bid meeting schedule in Annexure -2 Amendments/ Corrigendum if any will be notified only in Tender section

More information

Lessons Learned and Successful Root Cause Analysis of Elusive Ethernet Network Failures in Installed Systems

Lessons Learned and Successful Root Cause Analysis of Elusive Ethernet Network Failures in Installed Systems Lessons Learned and Successful Root Cause Analysis of Elusive Ethernet Network Failures in Installed Systems D. Dolezilek, J. Dearien, and M. van Rensburg Schweitzer Engineering Laboratories, Inc. Presented

More information

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording

Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as

More information

Management Software. SmartView TM EMS (Element Management System) 1-1. Management Software. Polled Network Elements

Management Software. SmartView TM EMS (Element Management System) 1-1. Management Software. Polled Network Elements Management Software Centralized Device Management Real-time visual representations & processing of alarms Long term event storage (up to 1 year) Easy, User-Friendly Operation Interface CTC Union s SmartView

More information

SEL Real-Time Automation Controller (RTAC)

SEL Real-Time Automation Controller (RTAC) SEL Real-Time Automation Controller (RTAC) Product Family Rugged, deterministic, and reliable automation controllers for any environment 1 ms deterministic processing intervals support critical protection

More information

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations. Products for digital substations SIPROTEC 7SC805 Merging Unit for conventional instrument transformer Integrated PRP, HSR www.siemens.com/processbus built to create digital substations based on IEC 61850-9-2

More information

This tutorial shows how to use ACE to Identify the true causes of poor response time Document the problems that are found

This tutorial shows how to use ACE to Identify the true causes of poor response time Document the problems that are found FTP Application Overview This tutorial shows how to use ACE to Identify the true causes of poor response time Document the problems that are found The screen images in this tutorial were captured while

More information

The Impact of the coming Standard IEC61850 on the Life-cycle of Open Communication Systems in Substations

The Impact of the coming Standard IEC61850 on the Life-cycle of Open Communication Systems in Substations The Impact of the coming Standard IEC61850 on the Life-cycle of Open Communication Systems in Substations Lars Andersson, Klaus-Peter Brand, Wolfgang Wimmer ABB Power Automation Ltd, Switzerland Abstract

More information

1U Rack Mounting 28-port 100M/Gigabit Layer 2 Managed Electricity Industrial Ethernet Switch

1U Rack Mounting 28-port 100M/Gigabit Layer 2 Managed Electricity Industrial Ethernet Switch MES5000 Series 1U Rack Mounting 28-port 100M/Gigabit Layer 2 Managed Electricity Industrial Ethernet Switch Support 4 gigabit fiber ports ( SFP slot) and 24 100M fiber/copper ports Conform to IEC61850

More information

Observer Probe Family

Observer Probe Family Observer Probe Family Distributed analysis for local and remote networks Monitor and troubleshoot vital network links in real time from any location Network Instruments offers a complete line of software

More information

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini White Paper Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini June 2016 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 9 Contents

More information

10Gbps Ethernet Solutions

10Gbps Ethernet Solutions Absolute Analysis Investigator 10Gbps Ethernet Solutions SFP+ Technology Provides Lower Cost, Longer Range with 10GBase-LRM Interface Compliance Support True 100% full line rate traffic capture with absolutely

More information

Impact of IEC communication protocol on substation automation systems

Impact of IEC communication protocol on substation automation systems International Journal of Research in Advanced Engineering and Technology ISSN: 2455-0876; Impact Factor: RJIF 5.44 www.engineeringresearchjournal.com Volume 2; Issue 5; September 2016; Page No. 49-53 Impact

More information

irbx6gf Features Intelligent 6 Port HSR/PRP Ethernet Switch IEC and IEEE 1613 Compliant

irbx6gf Features Intelligent 6 Port HSR/PRP Ethernet Switch IEC and IEEE 1613 Compliant irbx6gf www.is5com.com Intelligent 6 Port HSR/PRP Ethernet Switch IEC 61850 and IEEE 1613 Compliant Features Fully compliant with IEC 62439-3 HSR High-availability Seamless Redundancy Supports 4 x 10/100/1000Base-T(X)

More information

Advanced Network Routers. Datasheet. Model: ERPro-8, ER-8, ERPoe-5, ERLite-3. Sophisticated Routing Features

Advanced Network Routers. Datasheet. Model: ERPro-8, ER-8, ERPoe-5, ERLite-3. Sophisticated Routing Features Advanced Network Routers Model: ERPro-8, ER-8, ERPoe-5, ERLite-3 Sophisticated Routing Features Advanced Security, Monitoring, and Management High-Performance Gigabit Ports Advanced Routing Technology

More information

Merging unit ENMU. Manual

Merging unit ENMU. Manual Merging unit ENMU Manual ENMU.422100.001 manual. Rev 5.2017 Table of content Table of content Introduction... 3 Glossary... 4 1 General information... 5 2 Features... 6 3 Specification... 7 3.1 Measurement

More information

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens. Products for digital substations SIPROTEC 6MU805 Merging Unit for conventional instrument transformer Integrated PRP, HSR siemens.com/processbus built to create digital substations based on IEC 61850-9-2

More information

Q.brixx station 101. Base Unit with Test Controller. Most important features:

Q.brixx station 101. Base Unit with Test Controller. Most important features: Most important features: Q.brixx base unit consists of side handles, Test Controller Q.brixx station and power supply unit, ready for 14 measurement modules in the same housing and up to 32 plug-in modules

More information

Hadron Xtorm Series Remote Terminal Units

Hadron Xtorm Series Remote Terminal Units Hadron Xtorm Series Remote Terminal Units www.beijerelectronics.com Overcoming your challenges Fast: superior processing speed and high performance protocols Rugged: rugged design for operation in critical

More information