IECEx Certificate of Conformity

Size: px
Start display at page:

Download "IECEx Certificate of Conformity"

Transcription

1 Annex Page 1 of 9 Details associated with Issue 2 Changes: Change in ambient range to include the upper limit of +65 C for Junction Boxes fitted with Terminal blocks series UK N (IECEx KEM U). Re-evaluation of Models EP/DP4237 and EP/DP6042 for applications involving low risk of mechanical impact. Addition of model EP/DP4227, for applications involving low risk of mechanical impact. Operation heads (IECEx CQM U) and Switches (IECEx CQM U) can now be used. Change in IP rating from IP65 to IP66 when fitted with Operation Heads (operators). Drawing numbers GC0325, GC0327, GC0333 (sheets 2 and 3), GC0353 (sheets 2 and 3) have been removed. Clarification on IP rating for Issues 0 and 1 of this Annex. Conditions of certification: Limiting parameters and temperature classification are listed below. Table 1: Maximum Power Dissipation and Temperature Classification (Applies to - Junction Boxes fitted with Terminal Block series UK N (IECEx KEM U)) Maximum power dissipation (W) (-20 C Ta +65 C) T6 / T80 C T5 / T95 C EP/DP EP/DP EP/DP EP/DP EP/DP Table 2: EP/DP4227 Series Maximum Power Dissipation and Temperature Classification Maximum power dissipation (W) Configuration -20 C Ta +40 C Other than AWAM2 Ammeter, Fuse Type 8560/.. & window option With AWAM2 Ammeter or Fuse Type 8560/.. (for DP 4227) or window option Certificate numbers for Field bus barriers, Megablock IS terminals, Segment protectors and Ammeter Type AWAM2 are listed in this certificate. T6 / T80 C T5 / T95 C T6 / T80 C T5 / T95 C Field bus barriers, Megablock or Segment protectors N/A N/A

2 Annex Page 2 of 9 Table 3: EP4227 Range Maximum Current and Temperature Classification T5 (-20 C Tamb +40 C) Maximum current (A) T4 (-20 C Tamb +40 C) EP Range with Fuse Type 8560/ A short circuit protection device, rated at not greater than 10A, must be fitted in series with the Ammeter Type AWAM2. The equipment was submitted to tests corresponding to the low risk of mechanical impact and this must be observed at installation. The square polycarbonate window, when fitted in the enclosures, may generate an ignitioncapable level of electrostatic charge under certain extreme conditions. The user must ensure that the equipment is installed and used in accordance with the manufacturer's instruction manual. Marking details: DP Range of Junction Boxes: Ex td A21 T 1 C IP** -20 C Ta +65 C DP4227 Series Control Stations: Ex td A21 T 2 C IP** EP Range of Junction Boxes: Ex e II T 1 IP** -20 C Ta +65 C EP4227 Range of Control Stations: Ex # T 3 IP** Notes: T 1 - refer Table 1 T 2 - refer Table 2 T 3 - refer Tables 2 and 3 # - refer Table 4 Ambient temperature range marked for extended range only.

3 Annex Page 3 of 9 IP** IP65 for EP/DP4237, EP/DP6042 and models fitted with separately certified Ex de IP65 Operators listed in this certificate. IP66 for applications involving low risk of mechanical impact and when fitted with the separately certified Operation Heads listed in this certificate. IP66 (EP/DP Series Junction Boxes) for applications involving low risk of mechanical impact. No IP rating marked for equipment fitted with separately certified Ex dem and Ex de Indicating lights listed in the certificate. IP65 for enclosures fitted with separately certified Operation Heads listed in this certificate. This is an optional marking. Note: For Control Stations, the IP rating applies if the fitted devices have at least the same IP rating. Table 4: Marking information for EP Range when fitted with separately certified devices Device Operation Head Switches Meters Indicator lights Fuse Marking e IIC de IIC e II de IIC or dem IIC em II Manufacturer s documents: Drawing No Subject Rev. Date GC0324 GC0326 GC0331 GC0333 Ex e II T* IP66 Ex td IP66 T* o C JUNCTION BOX & CONTROL STATION Cat No EP1511 AND DP1511 Ex e II T* IP66 Ex td II T* IP66 JUNCTION BOX & CONTROL STATION Cat No: EP2315 AND DP2315 Ex e II Ex td T* IP6* EP4227 & DP4227 JUNCTION BOX / CONTROL STATION Ex e II Ex td T* IP6* EP6042 & DP6042 JUNCTION BOX / CONTROL STATION Drawing list continued next page 2 25/10/ /10/ /10/10

4 Annex Page 4 of 9 Drawing No Subject Rev. Date GC0353 GC0355 Sheet 1 of 3 GC0355 Sheet 2 of 3 GC0355 Sheet 3 of 3 GC0359 EPDPGMI Ex e II Ex td T* IP6* EP4237 & DP4237 JUNCTION BOX / CONTROL STATION Ex de II Ex td T* IP6* EP**** & DP**** CONTROL STATION Ex de II Ex td T* IP6* EP**** & DP**** CONTROL STATION Ex de II Ex td T* IP6* EP**** & DP**** CONTROL STATION Ex eim II Ex td T* IP66/65 GRP ENCLOSURE EP**** & DP**** JUNCTION BOX & CONTROL STATION CONNECTION BLOCKS FIELD BUS BARRIER FIELD BUS SYSTEMS GENERAL INSTRUCTION & MAINTENANCE INSTRUCTIONS 2 25/10/ /10/10

5 Annex Page 5 of 9 Details associated with Issue 1 Changes: Option for use of the following in the enclosure: Megablock Series IS terminals (IECEx CSA X) Segment protector type R-SP-E*** (IECEx PTB X) Field bus barrier (IECEx PTB ) Note: Changes apply to the models listed in Table 5. Conditions of certification: The maximum allowable power dissipation assigned in Table 5 applies when fitted with the separately certified Field bus barriers, Megablock IS terminals or Segment protectors in order to limit the maximum internal ambient temperature of the enclosure to 70 C. Table 5: Maximum Power Dissipation (W) Maximum power dissipation (W) T4 / T80 C (-20 C Ta +40 C) T4 / T80 C () EP/DP EP/DP EP/DP EP/DP Marking details: DP Range of Junction Boxes and Control Stations: Ex td A21 T80 C IP** EP Range of Junction Boxes and Control Stations: Ex # T4 IP** Notes: Ambient temperature range marked for extended range only. ** IP65 for EP/DP4237 & EP/DP6042 IP66 for EP/DP1511 & EP/DP2315 IP65 for enclosures fitted with Ex de Pushbuttons and Switch operators, refer Issue 0 of the certificate. Note: For Control Stations, the IP rating applies if the fitted devices have at least the same IP rating.

6 Annex Page 6 of 9 # As per Table 6 when fitted with separately certified devices: Table 6: Marking information for EP Range when fitted with separately certified devices Device Field bus barriers (IECEx PTB ) Megablock IS terminals (IECEx CSA X) Segment protectors (IECEx PTB X) Marking me [ia] IIC e ia IIC me II Manufacturer s documents: Drawing No Subject Rev. Date GC0359 EPDPGMI Ex eim II Ex td T* IP66/65 GRP ENCLOSURE EP**** & DP**** JUNCTION BOX & CONTROL STATION CONNECTION BLOCKS FIELD BUS BARRIER FIELDBUS SYSTEMS GENERAL INSTALLATION & MAINTENANCE INSTRUCTIONS /11/09

7 Annex Page 7 of 9 Details associated with Issue 0 Conditions of Certification: Limiting parameters and temperature classification are listed in Tables 7, 8 and 9. Table 7: EP/DP Range Maximum Power Dissipation and Temperature Classification Maximum allowable power dissipation (W) -20 C Ta +40 C T6 / T80 C T5 / T95 C T6 / T80 C T5 / T95 C EP/DP EP/DP EP/DP EP/DP Table 8: EP Range Maximum Current and Temperature Classification T5 (-20 C Tamb +40 C) Maximum current (A) T4 (-20 C Tamb +40 C) EP Range with Fuse Type 8560/ The following limiting parameters apply when the equipment is fitted with the window option and/or Ammeter Type AWAM2 (IECEx BAS U): A short circuit protection device, rated at not greater than 10A, must be fitted in series with the Ammeter. The maximum power dissipation of the equipment listed in Table 9 must not be exceeded Table 9: Maximum Power Dissipation for equipment fitted with Ammeter Type AWAM2 and/or window Maximum power dissipation (W) (-20 C Ta +40 C) () T6 / T80 C T5 / T95 C T6 / T80 C T5 / T95 C EP/DP EP/DP EP/DP EP/DP

8 Annex Page 8 of 9 The EP/DP1511 & EP/DP2315 models were submitted to tests corresponding to the low risk of mechanical danger and this must be observed at installation. The square polycarbonate window, when fitted in the enclosures, may generate an ignitioncapable level of electrostatic charge under certain extreme conditions. The user must ensure that the equipment is installed and used in accordance with the manufacturer's instruction manual. Marking details: DP Range of Junction Boxes and Control Stations: Ex td A21 T* C IP** EP Range of Junction Boxes: Ex e II T* IP** EP Range of Control Stations: Ex # T* IP** Notes: T* - refer Table 7, 8 (EP Range only) and 9 Ambient temperature range marked for extended range only. ** IP65 for EP/DP4237 & EP/DP6042 IP66 for EP/DP1511 & EP/DP2315 IP65 for enclosures fitted with separately certified Ex de Pushbuttons and Switch operators Note: For Control Stations, the IP rating applies if the fitted devices have at least the same IP rating. # As per Table 10 when fitted with separately certified devices with marking as shown: Table 10: Marking information for EP Range when fitted with separately certified devices Device Pushbutton Switches Meters Indicator lights Fuse Marking de IIC de IIC e II de IIC or dem IIC em II

9 Annex Page 9 of 9 Manufacturer s documents: Drawing No Subject Rev. Date GC0324 GC0325 GC0326 GC0327 GC0333 Sheet 1 of 3 GC0333 Sheet 2 of 3 GC0333 Sheet 3 of 3 GC0353 Sheet 1 of 3 GC0353 Sheet 2 of 3 GC0353 Sheet 3 of 3 GC0355 Sheets 1 & 2 of 2 GC0290 Sheet 4 of 4 Ex e II T* IP66 Ex td IP66 T80 o C JUNCTION BOX Cat No EP1511 AND DP1511 Ex e II T* IP65 Ex td IP66 T80 o C CONTROL STATION Cat No EP1511 AND DP1511 Ex e IIC Ex td T6 IP66 JUNCTION BOX Cat No: EP2315 AND DP2315 Ex e II Ex td T6 IP65 CONTROL STATION ARRANGEMENT DETAIL CAT No EP2315 AND DP2315 Ex e II Ex td T* IP65 EP6042 & DP6042 JUNCTION BOX Ex de II Ex td T* IP65 EP6042 & DP6042 CONTROL STATION Ex e II Ex td T* IP65 EP6042 & DP6042 JUNCTION BOX DETAILS Ex e II Ex td T* IP65 EP4237 & DP4237 JUNCTION BOX Ex de II Ex td T* IP65 EP4237 & DP4237 CONTROL STATION Ex e II Ex td T* IP65 EP4237 & DP4237 JUNCTION BOX DETAILS Ex de II Ex td T* IP65 EP**** & DP**** CONTROL STATION Ex de IIC IP6* SWITCHES & VIEWING WINDOW CONTROL STATION OPERATORS EPDPGMI EP-DP / Ex e & Ex td GC0285 Sheet 2 of 2 Ex e & Ex td IP6* SQUARE WINDOW DETAILS FOR EP/DP2315, EP/DP4237 & EP/DP6042 RANGE ES/DS2315, ES/DS3030,ES/DS4050, ES/DS5060, ES/DS6090 RANGE 0 16/02/09

I Ex-Installation switch I

I Ex-Installation switch I I Ex-Installation switch I Switch/Pushbutton Technical data 4 Ex-installation switch and Ex-pushbuttons Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Safety Instructions Cerabar M PMC51, PMP51, PMP55 XA00470P-B/00/EN/14.13 71224652 Products Solutions Services Safety Instructions PMC51, PMP51, PMP55 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6...T4 Ga/Gb Ex ia IIC T6...T3 Ga/Gb IECEx

More information

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product

More information

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus Safety Instructions PMC71, PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6 Ga/Gb IECEx KEM06.0011 0 XA00696P-D Safety instructions for electrical apparatus for explosion-hazardous

More information

Series Panel Mounted Control Devices

Series Panel Mounted Control Devices E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:3 Status: Current Date of Issue: 2012-10-12

More information

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety

ATX JBEA and ECEA Series Aluminum Enclosures Increased Safety Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,

More information

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX Connectors, Plugs & s Technical Datasheet Table of Contents Selection Guide 2 16A Range (ELCX 0251..) 3 32A Range (ELCX 0252..) 5 63A Range (ELCX 0253..) 7 125A Range (ELCX 0254..) 9 Elecex Ltd, Unit 9,

More information

Terminal Boxes Series 8118

Terminal Boxes Series 8118 > Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree

More information

The Solid-State Decoupler (SSD)

The Solid-State Decoupler (SSD) The Solid-State Decoupler (SSD) Installation Instructions Introduction The Solid-State Decoupler (SSD) is a solid-state DC isolation/ac grounding (i.e., coupling) device design ed for use in conjunction

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com issue No.:2 Status: Current Certificate history:

More information

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function

More information

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur For Foundation fieldbus networks in hazardous areas Complete enclosure systems for 6 or 12 intrinsically

More information

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Safety instructions. IECEx TUN Ex ia IIC T6 Gb Safety instructions ÜSB62-36G.C_* and ÜSB62-30W.C_* IECEx TUN 07.0002 Ex [ia Ga] IIC T6 Gb Ex ia IIC T6 Gb 0044 39878 Content 1 Area of applicability 3 2 General 3 3 Electrical data 3 3.1 Application conditions

More information

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - P O W E R C I R C U I T B R E A K E R S Up to 630 A CEAG power circuit breakers enable making or breaking of circuits under normal operating conditions as well as cutting in, briefly conducting and

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch selector switch > 2 contact elements

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N Cradle relay AC Cradle relay for alternating voltage, neutral, monostable. High-quality cradle relays for AC are installed as encapsulated flameproof elements in the MODEX enclosure. The IP 66 protection

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

INSTALLATION TECHNOLOGY MADE EASY

INSTALLATION TECHNOLOGY MADE EASY INSTALLATION TECHNOLOGY MADE EASY Pre-assembled branching/terminal boxes for Zone 1 and Zone 21 Each user can enjoy the benefits of the exlink with the pre-assembled branching boxes without having to first

More information

ICF-1150 Series Quick Installation Guide

ICF-1150 Series Quick Installation Guide ICF-1150 Series Quick Installation Guide Fifth Edition, July 2015 2015 Moxa Inc. All rights reserved. P/N: 1802011500014 1802011500014 Overview Introduction ICF-1150 series fiber converters have a multi-interface

More information

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Technical Data. General specifications. Output type Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone 2 and zone 22 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

Refer to attachment for more details. Andreas Meyer

Refer to attachment for more details. Andreas Meyer IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 50 mm flush -wire DC S Technical Data specifications Switching function Normally open (NO) Output type PNP Rated operating distance s n 50 mm Installation flush Output polarity DC

More information

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description Repeater power supply, active Data sheet 09_en_0 PHOENIX CONTACT 0--0 Description The. mm wide... repeater power supply supplies transmitters in the field and electrically isolates the input signal from

More information

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET WirelessHART components Gateway and accessories 2 Measurement made easy The ABB offering on WirelessHART accessories connect wireless sensors to the automation

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

MINI MCR-SL-CVS NC

MINI MCR-SL-CVS NC Constant voltage source Data sheet 105264_en_01 PHOENIX CONTACT 2013-04-03 1 Description Configurable constant voltage source for generating highprecision constant voltages. The voltage supply is also

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE Page 1 / 6 File number: ACE15/777/1 Product code: 2532H This certificate is not valid when presented without the full attached schedule composed of 7 sections www.veristar.com This certificate is issued

More information

Load Disconnect Switches and Motor Switches

Load Disconnect Switches and Motor Switches Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,

More information

Micro Motion, Inc. Page 1 of 6

Micro Motion, Inc. Page 1 of 6 EB-20025742 Revision: AA Number of Pages: 6 Comments: Originator: HVH 10/01/13 Approved: RCS 11/26/13 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 11/26/13 Micro Motion, Inc. Page

More information

Position Switches Series 8070

Position Switches Series 8070 www.stahl.de > Enclosures of type of protection "Increased safety > Dimensions and characteristic values according to EN 50041 > Replaceable contact in flameproof enclosure > Positive opening contacts

More information

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.

Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7

More information

SolConeX extra-low voltage flange socket

SolConeX extra-low voltage flange socket SolConeX extra-low voltage flange socket Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available

More information

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32 With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

Micro Limit Switch Series 8064

Micro Limit Switch Series 8064 > For universal application > Versions with snap-action contact positive opening contact > With connecting cable or with single cores when it is used as a built-in device > Width Single limit switch 11

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071 www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or

More information

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital Design Benefits The Future is Digital Teo Puay Yong Pepperl+Fuchs On Behalf of FF Marketing Society 1 The Future is Digital Design Benefits from Applying Foundation Fieldbus Bus structure and Wiring Loop

More information

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire / IECEx BVS 16.0091 X Types 8791, 8792, 8793 Position controller and process controller with II 3G Ex ec ic IIC T4 Gc / II 3D Ex tc IIIC T135 C Dc approval Stellungsregler und Prozessregler mit Zulassung

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S D5090S INSTRUCTI MANUAL 4 A Relay Output Module for NE, DIN-Rail and Termination Board, Model D5090S D5090-4 A Relay Output Module for NE G.M. International ISM09-3 Characteristics General Description:

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves 9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

ARC 600 & 1200 LED LAMP FOR Ex-ENVIRONMENT

ARC 600 & 1200 LED LAMP FOR Ex-ENVIRONMENT ARC 600 & 1200 LED LAMP FOR Ex-ENVIRONMENT Author : Barel AS Rev 9 Date : 07.11.2017 Barel AS 9917 Kirkenes Norway www.barel.no CONTENTS : 1 APPLICATIONS... 2 2 APPROVALS... 2 3 TECHNICAL DATA... 3 3.1

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No.

More information

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12 www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently

More information

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection.

Data sheet. Constant current DALI LED control gear 80 W Output power ma Output current Intelligent temperature protection. Data sheet Constant current DALI LED control gear 8 W Output power 5 7 ma Output current Intelligent temperature protection Linear VI LED Linear VI LED control gear More than 25 years of experience in

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

Page 1 of 5. Increased Safety, Encapsulation and Dust

Page 1 of 5. Increased Safety, Encapsulation and Dust IEC INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www iecex com Certificate No.: Status: Date of Issue: IECEx

More information

Automated Precision Weighing

Automated Precision Weighing Automated Precision Weighing Smart Load-Cell Technology The load cell, with Monobloc technology, is at the core of the SLF6-Series load cells and guarantees the highest precision and reliability. A robust

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx ITA 14.0009X Issue No:

More information

SolConeX Wall-Mounted Socket, 16 A

SolConeX Wall-Mounted Socket, 16 A SolConeX Wall-Mounted Socket, 16 A Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information Regarding the

More information

Ex-control switch Typ 292 without and Typ 293 with measuring instrument

Ex-control switch Typ 292 without and Typ 293 with measuring instrument Ex-control switch GHG 9 and GHG 9 GHG 9 GHG 9 Technical data Ex-control switch Typ 9 without and Typ 9 with measuring instrument with GHG 9 Switch with GHG Switch Marking accd. to 0//EU D II G Ex ed ia

More information

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety MRE Series 16 and 32 Amp Multiple Socket Outlets Applications Plugs and sockets are used with portable or stationary electrical equipment such as: Lighting systems Conveyors Heaters Motor generators Air

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction. Technical information TI 063R/09/en Mat. No. 510 00857 Process display RIA 251 Digital loop powered display for 4...20 ma current loops Application areas Plant and machine construction Control panels Laboratory

More information

1756 ControlLogix Chassis Specifications

1756 ControlLogix Chassis Specifications Technical Data 1756 ControlLogix Chassis Specifications Catalog Numbers 1756-A4/B, 1756-A7/B, 1756-A10/B, 1756-A13/B, 1756-A17/B, 1756-A4LXT, 1756-A5XT, 1756-A7LXT, 1756-A7XT Topic Page Standard ControlLogix

More information

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof 757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP

More information

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21

PTB 01 ATEX Operating Instructions. Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Solenoid coil Type AC21 Magnetspule Typ AC21 Bobine magnetique AC21 Device with II 2G EX i approval Geräte mit II 2G EX i Zulassung Appareils avec mode de protection II 2G EX i Operating Instructions Bedienungsanleitung

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: Date of lssue: Applicant:

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx BKI 07.0001X issue No.:1

More information

SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE

SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE 1. SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE 2. Equipment or Protective System Intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3. Type Examination Certificate Number: ITS13ATEX47876X/1

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Installation Instruction. HART Add-On Module

Installation Instruction. HART Add-On Module - Translation Typs 17-A1Z0-0005, B7-A2Z0-0033 and G7-A0Z0-0007 Version for: Non hazardous areas ATEX/IECEx Zone 1 and Zone 2 UL Class I Division 1 and Division 2 Document No.: B1-A2Z0-7N0001 / 400570 Revision

More information

MINI MCR-SL-UI-2I(-SP)(-NC)

MINI MCR-SL-UI-2I(-SP)(-NC) Data Sheet 03/2005 Product Description Features Configurable signal duplicator MINI MCR-SL-UI-2I(-SP)(-NC) is used to electrically isolate, condition, amplify, and filter analog standard signals. On the

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

EXPLORER. Industrial Panel PC - Flexible Modular Design

EXPLORER. Industrial Panel PC - Flexible Modular Design Gecma Explorer series HAZARDOUS AREA PC s Ex Zone 1 / 2 (Gas) Ex Zone 21 / 22 (Dust) Hazardous areas Industrial Panel PC - Flexible Modular Design For Ex Zone 1 / 2 (Gas) Class I, Zone 1 / Class I, Div.

More information

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3

BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3 BA448CF-F FOUNDATION fieldbus Intrinsically safe Panel mounting 8 variable Fieldbus Indicator Issue 3 Issue: 3 23 rd June 2011 2 CONTENTS 1. Description 1.1 Documentation 2. Operation 2.1 Error messages

More information

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN

NEW NEW NEW NEW NEW NEW Electrical specification ESP SL06 ESP SL15 ESP SL30 ESP SL50 ESP SL110 ESP SL TN Line Current rating In-line resistance Nottingham, NG EB, UK 0V 6.7V 750mA.0Ω 0kA 6V ESP SL Series Combined Category D, C, B tested protector (to BS EN 66) suitable for twisted pair signalling applications

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

F101, F102, F104. Relcom  Installation Instructions. Fieldbus Power Supply F101-PS F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting

More information

MINI MCR-SL-PT100-UI-200

MINI MCR-SL-PT100-UI-200 Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate : IECEx PTB 04.0005 http://iecex.iec.ch/iecex/iecexweb.nsf/certificatesajax/iecex%20ptb%2004.0005%... Seite 1 von 4 10.01.2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme

More information

Operating manual ELX channel digital input terminal for NAMUR sensors, Ex i. Version: Date:

Operating manual ELX channel digital input terminal for NAMUR sensors, Ex i. Version: Date: Operating manual ELX1052 2-channel digital input terminal for NAMUR sensors, Ex i Version: Date: 1.5.0 2018-08-08 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation...

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the ECEx Scheme visit www.iecex.com Certificate No.: Status: Current Issue No: 1 Certificate

More information

SA-P. Ex e. Stainless steel captive screws. Metal plates riveted onto lid

SA-P. Ex e. Stainless steel captive screws. Metal plates riveted onto lid SA-P - Zone 1, 2, 21, 22 - Polyester junction boxes - Choice of 9 sizes - With antistatic property - IK10 mechanical strength - IP66 Metal plates riveted onto lid Stainless steel captive screws ORIGINAL

More information

Operating manual ELX9012, ELX9410, ELX9560. ELX System Terminals. Version: Date:

Operating manual ELX9012, ELX9410, ELX9560. ELX System Terminals. Version: Date: Operating manual ELX9012, ELX9410, ELX9560 ELX System Terminals Version: Date: 1.5.0 2018-08-08 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

Fisher i2p-100 Electro-Pneumatic Transducer

Fisher i2p-100 Electro-Pneumatic Transducer i2p-100 Transducer Product Bulletin Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional

More information

21023, 21025, 2/2 Direct solenoid actuated poppet valves

21023, 21025, 2/2 Direct solenoid actuated poppet valves 03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international

More information

(1) EC-TYPE-EXAMINATION CERTIFICATE (Translation) (2) Equipment and protective systems intended for use in potentially explosive atmospheres Directive 94/9/EC (3) EC-type-examination Certificate number

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx UL 15.0032X Current

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information