1 Outdoor Cabinet for OFF-GRID Systems v Outdoor Steel Cabinet v Durable Epoxy-Polyester Powder Coating v Supplied Cabinet s Equipments - MPPT Charger with PoE+ Injector - Automatic Turbine Brake - Overvoltage Protection of PV Power Supply - Shelf for 60 Ah Battery - Outdoor Antenna - Overpressure Fuse - Lock with Key - DIN35 rail, Terminals, Fuses and Internal Cabling v Optional Equipment - PLC IPLOG-GAMA v Optional Accessories - Holders for Cabinet Installation - Overvoltage Protection for LAN Input / PoE+ Output PRODUCT NAME CODE NOTE 1-POE G/3G 1-LTE-POE G/3G/4G-LTE 2-LTE-POE G/3G/4G-LTE Description Cabinets are a flexible solution for island monitoring and controlling systems. The modular PLC IPLOG offers a wide range of inputs, outputs and communication interfaces. Thanks to this, the customer can build a system exactly to their specifications. Supplied Equipment The Cabinets are supplied include the interconnected and tested equipments listed in the table below. The exact PLC model is ordered separately. Selecting the PLC is recommended in the online configurator available at Refer to page 3 for recommended battery types, PV panels and wind turbines. MPPT PoE+ Charger Automatic Turbine Brake OVP for Powering BM-MPPT-6-PoE BM-TPB-35 OVP-1/24/10-BOX 1-POE Yes - Yes 1-LTE-POE Yes - Yes 2-LTE-POE Yes Yes Yes Example of the 1-LTE-POE Version FV panel OVP MPPT Charger with PoE+ Injector Industrial PLC IPLOG-Gx with IO IR Light + BM-M PPT-6-PoE # VI N1 FU SE 7,5A/32V VI N2 A+ B- TS RS 485 ST Rx/Tx +VBat LAN -VBat 10/ 100 VO UT LAN 10/ 100 PoE+ LTE Sensors 1/10
2 I O Outdoot Cabinet for OFF-GRID Systems Example of the 2-LTE-POE Version Sources of Energy Camera Overvoltage Protections Automatic Turbine Brake VI N1 FU SE 7,5A/32V MPPT Charger with PoE+ Injector + BM-M PPT-6-PoE # VI N2 A+ B- TS RS 485 ST Rx/Tx +VBat -VBat VO UT LAN 10/ 100 LAN 10/ 100 PoE+ IR Light Industrial PLC IPLOG-Gx with IO LTE Sensors Serial Interfaces - RS485, RS232, DALI, Audio, Wiegand, 1-Wire. 2/10
3 Outdoor Cabinet for OFF-GRID Systems Power Sources and System Design When designing an island system, local climatic conditions must be taken into account. Particularly important is the frequenc y of sunny days, the average wind strength and its stability, the presence of fog or inverse weather, etc. The system can only use solar energy or combine solar energy with wind. Everything depends on local conditions. In the event of unfavorable weather forecasts, the PLC can switch the system into a standby mode. A typical example is the PoE camera startup only in case of an alarm. It is generally recommended to dimension the system for at least 2 days of battery operation without recharging. Photovoltaic Panels The energy generated by photovoltaic panels has the fundamental advantage of being regularly available. Even on a cloudy or rainy day, at least about 10% of the rated power is produced. The number of panels installed and their overall power must match the power of the powered devices. Wind Turbine The wind turbine is a suitable complement to the system, especially in seaside and mountain areas. In order for the turbine to be deployed, there must be sufficient days at the installation site with a constant wind speed of 5 m/s. The opposite occurs in strong wind where the propeller must be braked by the BM- TPB-35 automatic brake. This prevents the critical turbine speed exceeding and the voltage at the charger input exceeding the permitted 30 VDC. The overvoltage protection is also part of the brake. Battery The system backs up a gel battery, such as BAT A critical period for the battery is during the winter period, when the charging time of the battery at full power is shortened to a maximum of 6h between 10h in the morning and 16h in the afternoon (Central Europe). In addition, due to low temperatures, the capacity drops by up to 50% at -20 C. Components of the cabinet are the shelves for the placement of the battery and an overpressure fuse to allow pressure equalization when the battery produces hydrogen during charging. Lightning Conductor and Earthing Direct lightning strike into the unprotected mast may mean the destruction of electronic devices on the mast and in its immediate vicinity. The best protection is the installation of the auxiliary collector and its grounding. The auxiliary collector prevents direct lightning strikes in sensitive electronic devices. Detailed calculations regarding the construction of the auxiliary collector are contained in EN Generally, the turbine and all other electronic devices are hidden in the protective angle of the collector. Optional Accessories Installation on a Wall When mounting to a wall it is recommended to use the KIT-OH with 4 pieces of steel brackets (galvanized) and mounting accessories. KIT-OH Installation on a Pole When you install on a pole mm it is recommended to use kit HOLDER-OH6425. HOLDER-OH LAN Overvoltage Protection In the case the UTP/FTP cable is connected to the PLC LAN port, it is recommended to install the OVP- 100M-HIPOE overvoltage protection inside the cabinet. OVP-100M-HIPOE /10
4 Outdoot Cabinet for OFF-GRID Systems Technical Parameters Parameter Values Unit Notes Mechanics Power Inputs 1x FVE 12 V Polycrystalline Panels 1x 12 V Wind Turbine Operating Voltages Max. 30 VDC max 10 A Recomm. PE Wire Cross-Section 6 mm² PE Terminal to the Bottom Left Glands 6 ks PG9 Tamper Door Closed = Closed Contact IP Code Dimensions - W / H / D 400 x 600 x 250 mm Material Galvanized Steel Surface Finish Epoxy-Polyester Powder Enclosure Grey RAL 7035 Weight Max. 50 kg With Equipment BM-MPPT-6-PoE Number LAN with PoE / 7-8 Supported Formats 10/100 BaseT Connector RJ45 Overvoltage Protection Pins 4-5/7-8: Lightning Arresters + Transils Pins 1-2/3-6: without Protection PoE Output Max. 30 W IEEE 802.3af/at Output for Load Voltage Max. 30 VDC Maximal Current 2 A Overvoltage Protection 600 W 10/1000µs Output for Battery Technology Lead-Acid Charging Current Max. 6 A Short Circuit / Disch. Protection Fuse 7,5 A / Disconnet at VBAT < 10,8 Battery Temperature Sensor NTC termistor 103AT (is included) Remote Control Bus RS485 MODBUS-RTU / MIOS-2 Overvoltage Protection 600 W 10/1000µs Environment Operating Range C Cooling Controlled Fan Power Inputs Fusing Tube Fuses T-8A 5x20mm Overvoltage Protection OVP-1/24/10-BOX Antennas LTE version Outdoor Antenna 2G/3G/4G-LTE SMA Connectors Version without LTE Outdoor Antenna 2G/3G SMA Connectors LAN (output PLC) Overvoltage Protection OVP-100M-HIPOE Must be ordered separately Battery The size of the shelf 230 x 210 mm Recommended Battery Victron 60 Ah BAT Is not included Break BM-TPB-35 Modes Automatically Manual activation by a switch on the panel or remotely over the optron Brake Activation Signaling NO Relay and LED Recommended Type of Turbine i V Producer Ista Breeze Holder-OH6425 Permissible Load 50 kg Must be ordered separately Pole Diameter mm KIT-OH Permissible Load 50 kg Must be ordered separately The producer retains the right to change any technical parameters without previous written or published notification. 4/10
5 Outdoor Cabinet for OFF-GRID Systems 1-POE - Cabinet with PLC, Charger and Protections 5/10
6 Outdoot Cabinet for OFF-GRID Systems 1-LTE-POE - Cabinet with PLC, Charger and Protections 6/10
7 Outdoor Cabinet for OFF-GRID Systems 2-LTE-POE - Cabinet with PLC, Charger, Brake and Protections 7/10
8 Quick Installation Manual REV: Outdoor Cabinet for OFF-GRID Systems Installation 1. Mounting Screw the cabinet firmly using the assembly holes in the corners. a) for mounting to a flat surface. For mounting use kit KIT-OH. See page 9. b) mounting to the holder HOLDER-OH6425 (when mounting to a pole). Fasten the cabinet using the fastening bands that are included with the holder. Holders are designed for use on round poles with a diameter of: mm. The cabinet must always be installed in the vertical position with the outlets oriented to the bottom. When installing use fasteners in accordance with the instructions and illustrations on this and the following pages. 2. Grounded Cabinet and Overvoltage Protections The cabinet is grounded with copper wires of 6-10 mm 2. Screw the wires into the green terminals (right on the bottom DIN35 rail). Ground resistance must be maximum 10Ω. 4. Connect PLC and Other Hardware The PLC, charger and other components are connected inside the switchgear. Cables and wires leading outside the switchboard are installed by the customer at the installation site as shown below Power Sources Flip the fuse holder to disconnect the fuses on the bottom rail. Then connect the power supply to the terminals. To blue terminals minus pole and to fuse holder plus pole of power supply. Inputs VIN1 and VIN2 are equal. Before connecting the fuses, measure the PV panel voltage and the idle propeller. It must be less than 30 VDC Power Supply from a Wind Turbine 3 x 4 mm 2 k Power Supply from PV Panels 2 x 4 mm 2 l Grounding m UTP Cables n Coaxial Line from the Antenna SAFETY PRECAUTIONS vinstallation, adjustment and operation may only be carried out by a person with the appropriate electrotechnical qualifications who is fully familiar with this manual. vthe cabinet is designed for connection to 12V polycrystalline PV panels and wind turbines of 12V and must be installed in accordance with the regulations and standards applicable in the country. vinstallation must not be performed during a thunderstorm. vwhen installing a wind turbine and PV panels, the manufacturer's safety instructions must be followed. 8/10
9 Quick Installation Manual REV: Outdoor Cabinet for OFF-GRID Systems KIT-OH - Accessories for Cabinet Installation on a Flat Surface Holder from Kit KIT-OH 9/10
10 Quick Installation Manual REV: Outdoor Cabinet for OFF-GRID Systems HOLDER-OH Accessories for Cabinet Installation on a Pole HOLDER-OH6425 Bolt Spring Washer Stainless Steel Washer HOLDER-OH6425 Rubber Washer The Wall of the Cabinet Bolt Insert Revision: Default 10/10
Industrial PLC System
IPLOG Basic Parameters and Advatanges EN 60870--0 IEC 6- GSM LAN COM DI AI RE AO DO IPLOG-G IPLOG-G and G IO v IPLOGs are Linux based PLCs with Support for Writing User Scripts v IF s Support Modbus, M-BUS,
More informationSelectronic accessories to support the SelectSun 3 phase grid-tie inverter range
Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range Our all new SelectSun range of 3 phase solar inverters are equally at home with or without batteries. Available in 20kW
More informationPOE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from
POE084824B v.1.1 PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. EN* Edition: 7 from 15.11.2017 Supersedes the edition: 6 from 22.11.2016 GREEN POWER CCTV PoE PSU features: DC 54V uninterruptible
More informationAccessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)
25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The
More information2G-1.1.0, 200M-2.0.3, 200M-1.0.1
Unmanaged PoE Switches and Media Converters of LAN-BUS System, 200M-2.0.3, SWITCH* MEDIA CONVERTER* RACK IP65 Topology bus / star MM/SM universal 200M-2.0.3 and 200M-1.0.3 support PoE**** and support PoE
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationEmergency Luminaire for Fluorescent Lamps Series EXLUX 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationSwitched Mode Power Supply Operating manual PAP800
Features: Switched mode power supply Wide output 0 144Vdc Analog control by an external 0 5Vdc Power failure alarm output Master-slave connection Powerfinn PAP series is a high power, lightweight, advanced
More informationTechnical Information SMA STRING-MONITOR SSM-U-XX10 / SSM-U-XX15
Technical Information SMA STRING-MONITOR SSM-U-XX10 / SSM-U-XX15 SSMUXX1015-TI-en-10 Version 1.0 ENGLISH 1 Overview of Product Details SMA Solar Technology AG 1 Overview of Product Details Product Description
More informationSUN KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SUN2000-60KTL-M0 Quick Guide (Europe Edition) Issue: 01 Part Number: 91509499 Date: 2018-02-10 HUAWEI TECHNOLOGIES CO., LTD. NOTICE The information in this document is subject to change without notice.
More informationDC Outdoor Power Supply/Chargers
DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC
More informationReferences. References. Rating (A) Référence
DIRECT OPERATION T O O R D E R EXTERNAL OPERATION picto_080_c_1_gb Switch body Direct Switch body + handle + Shaft + + OTHER ACCESSORIES External handle acces_128_a_1_cat acces_129_a_1_cat Direct handle
More informationAC5160 SiPass integrated controller kit
AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one
More informationPerimeter Detection System - Installation manual
Perimeter Detection System - Installation manual The manual describes installation and configuration of the PERIDECT+ detection system and is intended exclusively for authorized partners of the manufacturer
More informationTSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13
Battery Controller Module TSP-BCM24, TSP-BCM24A TSP-BCM48, TSP-BCM48A Operating Instruction Manual http://www.tracopower.com Page 1 of 13 Dimensions drawings: TSP-BCM24 & TSP-BCM48 Weight: 0.816lb Gewicht:
More informationFeatures: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras
DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras Edition: 4 from 15.11.2017 Supercedes the edition: 3 from 30.03.2017 EN** Features: Uninterruptible power supply
More informationHCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures
HCS - Made in Turkey With Pride! HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures HCS, the only Turkish manufacturer of state-of-the-art LAN cabling systems
More information60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application
WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket
More informationFeatures: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras
S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationMSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range
MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules
More informationMounting and Technical Data
Technical Information Mounting and Technical Data / ontent This document describes the technical data, the assembly and selection of cables for the D main distribution and. SM_SM--TI-en-30 Version 3.0
More informationIndustrial PLC System
Pre-production datasheet - The producer retains the right to change any technical parameters without previous written notice EN 60870--0 IEC 6- GSM LAN COM DI AI RE AO DO PLC with port switch PLC with
More informationILUMEN PID SOLUTION INDOOR OUTDOOR ILUMEN PIDBOX MINI INSTALLATION MANUAL. Ilumen PIDbox mini Version 1.5
ILUMEN PID SOLUTION ILUMEN PIDBOX MINI INSTALLATION MANUAL INDOOR OUTDOOR Ilumen PIDbox mini Version 1.5 1 TABLE OF CONTENT 1 Information on this manual... 3 1.1 Validity... 3 1.2 Target group... 3 1.3
More informationBMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.
Version: 2011-01-13 BMCS CCX Cabinet Description & Function: The BMCS_CCX Cabinet is a ready to install wall housing for one or more BMCS systems (see figures 1 to 3). The BMCS_CCX Cabinet is designed
More informationSUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SUN2000-100KTL-USH0 Quick Guide Issue: 01 Part Number: 31509347 Date: 2018-02-08 HUAWEI TECHNOLOGIES CO., LTD. NOTICE The information in this document is subject to change without notice. Every effort
More informationAT-CAB. Surveillance Cabinet. Installation Guide. Rev IP Sur veillance. Document part no.: G
AT-CAB Surveillance Cabinet Installation Guide Rev. 1.0 Document part no.: 625034800G IP Sur veillance CAUTION: REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. UNPACKING: Unpack carefully. Electronic components
More informationArgenta W A L L M O U N T I N G M E T A L C A B I N E T S
Argenta W A L L M O U N T I N G M E T A L C A B I N E T S The ARGENTA Series is a group of metal enclosures used to house on the inside electrical or electronic switchgear, controlgear and equipment necessary
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More informationE-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS
E-KAB N E SERIES WALL- MOUNTED DISTRIBUTION SWITCHBOARDS DUVAR T P TES SAT KAB NLER www.eae-et.com.tr EAE Elektroteknik A.S. reserves rights to make changes within this document without prior notice. CONTENTS
More informationsonnen Installation Practical
sonnen Installation Practical sonnen Components sonnenbatterie eco 8.0 Single Phase System Components 4 sonnenbatterie eco 8.0 Single Phase System Components 5 sonnenbatterie eco 8.0 Single Phase System
More information1 Installing the VG4-A-ARMPLATE
VG4 24 VAC Mounting Plate Installing the VG4-A-ARMPLATE en 1 1 Installing the VG4-A-ARMPLATE This addendum provides supplemental information for the AutoDome Modular Camera System Installation Manual.
More informationAccessory Guide Indoor AP Accessories
Indoor AP Accessories INDOOR SKU Compatible Products Description Kit Contents 902-0120-0000 R720 R710 R700* R600* R610* R500* R510* R310 * fits AP, but does not support padlock security Multipurpose mounting
More informationNokeval. FD100 series. User Manual
Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device
More informationPassive network equipment. Catalog
Passive network equipment Catalog 2018 Table of Contents Cabinets, Open Rack, Server Chassis 4 Single section wall mount cabinets 6 Double section wall mount cabinets 8 Free standing cabinets FF01 series
More informationInsulated Enclosure KU 4090 to DIN for installation in distribution cabinets or surface mounting
Insulated Enclosure KU 4090 to DIN 43 880 for installation in distribution cabinets or surface mounting Width 105 mm Uo to 48 plus-minus-terminal screws with self raising terminal washers. Part insertion
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More informationINSTALL INSTRUCTIONS RSXMR-9886-P-48
INSTALL INSTRUCTIONS RSXMR-9886-P-48 Installation Instructions RSXMR-9886-P-48 (CEQ. 20194) INSTALL INSTRUCTIONS RSXMR-9886-P-48 Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings
More informationAccessory Guide ZoneFlex Indoor AP Accessories
ZoneFlex Indoor AP Accessories INDOOR SKU Compatible Products Description Kit Contents 902-0120-0000 ZoneFlex R720 ZoneFlex R710 ZoneFlex R700* ZoneFlex R600* ZoneFlex R610* ZoneFlex R500* ZoneFlex R510*
More informationInstallation manual APP _app541_inst_eng_rev1_00. Esc. Reset. Autamatic Pump Pilot APP 541
Installation manual APP 541 Esc OK Reset Autamatic Pump Pilot APP 541 895684_app541_inst_eng_rev1_00 This manual is applicable to the following APP 541 versions: Hardware: Operator panel: AFH1801 Rev 1.02
More informationQUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE
QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form
More informationFeatures: SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space
SF108-CR v1.1 SF108-CR 10-ports switch for 8 IP cameras in enclosure with recorder space Edition: 2 from 05.04.2018 Supercedes the edition: 1 from 04.09.2017 EN** Features: Switch 10 ports 8 PoE ports
More informationPlease take serious note of the following warnings:
TPDIN-SC48-20 MPPT Solar Controller with Passive PoE Switch Wireless Base Stations and Client Devices Surveillance Cameras Remote Control Remote Lighting Off Grid Electronics Congratulations! on your purchase
More informationCONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail
CONDUCTOR W Installation instruction for W. and W. 00 Controller To mount the controller. Mounting on a DIN rail Figure. Overview of the Controller. Pos. Product marking. Pos. Termination resistance. =
More informationFeatures: DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras
DSFB108 v1.1 DIN rail mounted switch 10-ports DSFB108 with buffer power supply for 8 IP cameras Edition: 3 from 07.03.2018 Supercedes the edition: 2 from 15.11.2017 EN** Features: Uninterruptible power
More informationTO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED SOCKETS IN THERMOSET TING MATERIAL
Page 1 TO ALL OUR CUSTOMERS 1. NEW ADVANCE GRP SERIES - 16A-32A-63A INTERLOCKED S IN THERMOSET TING MATERIAL ADVANCE GRP marks another leap forward in SCAME technological research. ADVANCE GRP is the most
More informationInnovative POWER Solutions
Innovative POWER Solutions ISO 9001 : 2008 REGISTERED QUALITY MANAGEMENT SYSTEM PANTROL, INC. INVITES YOU TO REVIEW A SAMPLING OF OUR STANDARD PRODUCTS LINE. FOR SPECIAL APPLICATIONS OR CONFIGURATIONS
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationSUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 14 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SUN2000 (8KTL-28KTL) Quick Installation Guide 0 Issue: 14 Part Number: 31044 Date: 2017-03-20 HUAWEI TECHNOLOGIES CO., LTD. NOTICE 1. Before you install the devices, closely read the SUN2000 (8KTL-28KTL)
More informationVertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1
15370 Barranca Parkway Irvine, CA 92618 USA VertX V100, V200 and V300 Installation Guide November 2011 6080-930 Rev A.1. Contents Introduction... 3 Parts List... 3 Product Specifications... 3 Cable Specifications...
More information2U Congestion Alert Rack Insert for UK
2U Congestion Alert Rack Insert for UK 2U Congestion Alert Rack Insert for UK The 2U congestion alert rack insert comes fully assembled, wired and ready to be installed in a rack. The rack provides communications,
More informationB&W RearView Camera Installation & Operation
B&W RearView Camera Installation & Operation CA52 (Camera) FOR MORE INFORMATION WWW.STRATEGICVISTA.COM BEFORE OPERATING THIS SYSTEM, PLEASE READ THIS MANUAL THOROUGHLY AND RETAIN IT FOR FUTURE REFERENCE
More informationDIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi
V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors
More informationSUN2000 (8KTL-28KTL) Quick Installation Guide. Issue: 13 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.
SUN2000 (8KTL-28KTL) Quick Installation Guide 0 Issue: 13 Part Number: 31044 Date: 201-08-03 HUAWEI TECHNOLOGIES CO., LTD. NOTICE 1. Before you install the devices, closely read the SUN2000 (8KTL-28KTL)
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationProduct data sheet accessories control and regulation Accessories AIRWIN
Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,
More informationmultisys User manual Technical parameters D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS _EDEBDA _EN
User manual Technical parameters multisys D2-MSMT-1 Gateway from Modbus TCP to Modbus RTU, serial RS485 System I English Your partner for network analysis KBR Kompensationsanlagenbau GmbH does not accept
More informationUniversal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications
12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception
More informationRemote Site Products
Battery Enclosures 32 Pole Mount Our Battery Enclosures include the following features: Manufactured to NEMA 1, 3, 3R and 12 standards, providing outdoor protection against wind, blown dust, rain, sleet,
More informationConnecting a Cisco Input Module
CHAPTER 4 Overview The optional Cisco Input Module (Figure 4-1) is attached to a Cisco Physical Access Gateway or Cisco Reader Module to provide additional connections for up to ten input devices. Each
More informationInForm Superstructures
Advantages InForm racks are fitted between the vertical profiles and thus ensure a generous amount of open working table surface. Devices are installed directly in the 3HU and 6HU racks, additional devices
More informationOperating instructions Evaluation system for flow sensors VS / / 2013
Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...
More informationPower-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Enclosure with Mounting Plate and Cooling Fan. Model: NB F. Applications and Features
Power-Over-Ethernet (PoE) Weatherproof 14 x12 x7 Mounting Plate and Cooling Fan Model: NB141207-40F Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power-Over-
More informationDirectCommand Installation DirectCommand Complete Wiring Harness
Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number With Switch Box Quantity by Model With Boom Switch Cable Display Cable Kit 4100814 1 1 Power Control
More informationInsulated Enclosure KU 4087, KU 4088 KU 4089 to DIN for installation in distribution cabinets or surface mounting
Insulated Enclosure KU 4087, KU 4088 KU 4089 to DIN 43 880 for installation in distribution cabinets or surface mounting Width 17,5 / 35 / 70 mm 8 / 16 / 32 plus-minus-terminal screws with self raising
More informationRecommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install
TPDIN-Monitor-WEB Web Based Monitor and Control Remote Power Stations Backup Power Systems Solar Systems Wind Powered Systems Industrial Sense & Control Process Automation Congratulations! on your purchase
More informationQuick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals
Quick Start Guide www.vaisala.com Vaisala NOMAD 3 Data Logger Preparation Package Contents Plan Instrumentation Create a SkyServe Account Activating the Nomad 3 Nomad 3 Toolbox Create Setup Files 2 4 5
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationAccessories for Sunny Central COMMUNICATION CABINET (COM-C)
Accessories for Sunny Central COMMUNICATION CABINET (COM-C) Technical Description COM-C-TEN084210 98-4011910 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Product Details...................................
More informationSystem Components Surge Arrester HAW 261 and HAW 262
Technical Information TI 108F/00/en System Components Surge Arrester and Operating Instructions Part. No. 017166-1000 for power supply side for signal input side (2-wire) (2 and 3-wire) Application The
More informationLantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual
Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationPV Module Installation Instructions
Name 1601A Page 1 / 8 Name 1601A Page 2 / 8 1 Introduction Thanks for purchasing PV modules of HT SOLAR ENERGY JOINT STOCK COMPANY This manual refers to PV modules manufactured and sold by HT Turkey. This
More informationInstallation Manual rev
Installation Manual rev. 20110418 This document contains installation instructions for the switches of the following versions: 200M-2.0.4.ECA 2G-2.0.4.ECA 200M-2.0.4.ECB 2G-2.0.4.ECB 200M-2.0.4.H-ECA 2G-2.0.4.H-ECA
More informationAccessory Guide Indoor AP Accessories
Indoor AP Accessories INDOOR 902-0120-0000 R720 R710 R700* R600* R610* R500* R510* R310 * fits AP, but does not support padlock security Multipurpose mounting bracket for indoor AP s supports mounting
More informationEN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems
CODE: TYPE: EN54-7A17 v.1.1/iv EN54 27,6V/7A/2x17Ah power supply for fire alarm systems EN** RED POWER 1438 Certificate of constancy of performance CNBOP-PIB No 1438-CPR-0385 Certificate of admittance
More informationCMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual
CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,
More informationAC5160 Controller. Fire & Security Products. SiPass integrated
AC5160 Controller SiPass integrated Wall housing with pre-assembled SiPass basic components Equipped with one ACC, two DRI and one power supply Extendable with additional components The AC5160 is a wall
More informationMBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit
MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch
More information2G(200M) E PoE++
BOX* Ring topology LAN-RING Overvoltage protection 1kA on FE ports 1x port with support of: APOLLO, ASSET, ATS, CIAS, DOMINUS, GALAXY, HUB-PRO, PERIDECT, ROR, SATEL-ACCO, SICURIT-ABSOLUTE, STATN-ONE, Modbus
More informationOvervoltage Protection in IP CCTV LAN-RING Systems
Overvoltage Protection in IP CCTV LAN-RING Systems rev. 20110111 1 Introduction This application note contains the rules for correct connection of overvoltage protections in IP CCTV systems LAN-RING. According
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More informationSystem Components Guide
System Components Guide 2011 Version 1.0 Gemini NavSoft Technologies Ltd. Fredericton, NB, Canada http://www.gemini-navsoft.com GNT GPS Position Solver is used to generate mm level accuracy, GPS position
More informationv.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit Requirements of Grade 1 Grade 2 Grade 3
CODE: TYPE: PSBEN 5024C EN** v.1.1/vi PSBEN 27,6V/5A/2x17Ah/EN buffer, switched mode power supply unit BLACK POWER Functional requirements This product is suitable for the systems designed in compliance
More informationAccessories and options
Novigo Accessories and options PCA2001-A1, PCA2002-A1, PCA2004-A1, PCA2005-A1, PCA2007-A1, PCA2008-A1, PCA2011-A1, PCA2012-A1, PCA2013-A1, PCIO2001-A1, PCO2001-A1, PNA2007-A1 Accessories and optional components
More informationOperating tunnels safely Overvoltage protection for critical systems in tunnels
Operating tunnels safely Overvoltage protection for critical systems in tunnels Dipl.-Ing. (FH) Martin Sandau Technical Support Business Unit Surge Protection 1 ITS 2013 19/09/13 Operating Tunnels Safely
More informationEN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. Requirements of. Grade 1 Grade 2 Grade 3
CODE: TYPE: EN** PSBEN 10A12D v.1.1/vii PSBEN 13,8V/10A/40Ah/EN buffer, switch mode power supply unit Grade 3. BLACK POWER H H 1 W W 1 D 1 D Functional requirements This product is suitable for the systems
More informationUser Manual. 3KW/5KW PV Inverter
User Manual 3KW/5KW PV Inverter (IP 20) Version: 1.0 Table Of Contents 1. Introduction... 1 1-1. Overview... 1 1-1. Affecting Factors for Performance of the Inverter... 1 2. Important Safety Warning...
More informationSurge Protection for Surveillance Systems
Surge Protection for Surveillance Systems 1-in-1 Protection for Network Cameras 2-in-1 Protection for Power and Audio/Video Signals 3-in-1 Protection for Power, Audio/Video and PTZ Control Signals Application:
More informationH3G-48B Production Description
H3G-48B Production Description Designed for communication battery strings of 24 batteries each of VRLA and Ni-Cd battery 1 Applications For strings of 24 batteries each Base Station (2V X 24 batteries)
More informationselos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail
The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail selos DIN rail terminal blocks with screw connection Reliable connection, proven concept!
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationPTC/PT100 board 2.0 Option
PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB
More informationCommunication interfaces
Communication interfaces Sunguard Datalogger SUNGUARD BOX HOME 20K 1PV SUNSY 018 A For photovoltaic installations of up to 20 kwp with one inverter. 2 RS232 serial ports. RS232/RS485 signal converter.
More informationUEMC 41 Motor Operating Device
Installation and operating instructions UEMC Motor Operating Device Your safety first always! All legally recognized standards, the connection conditions of the local electrical utility and the applicable
More informationHow to choose the correct Mount Kelvin central unit
Installation guide Outside world Property Wirepas mesh Mount Kelvin app Internet connection Ethernet DALI 3rd party integrations Mount Kelvin cloud Mount Kelvin central unit Voice control EnOcean wireless
More information19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43
9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air
More informationSafety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSunny Boy 2100TL Transformerless solar inverter Installation Guide
Sunny Boy 2100TL Transformerless solar inverter Installation Guide SB2100TL-11:SE0204 Table of Contents 1 Introduction................... 3 2 Safety Instructions............... 5 3 Overview.....................
More informationSmart-Node. All-in-One Power and Communication Solution
Smart-Node All-in-One Power and Communication Solution RADWIN Smart-Node is an outdoor power and communication solution that reduces costs and accelerates the roll-out of smart-city, IoT and telecom projects.
More information