1 QUICKSTART GUIDE MODEL 7600 Teledyne Analytical Instruments

2 Quickstart Guide Teledyne Analytical Instruments

3 Model 7600 Quickstart Guide GETTING STARTED This Quickstart Guide is designed to get you set up and operating your Teledyne Analytical Instruments Analyzer quickly. It shortcuts the details so you can install and use your new analyzer with a minimum of fuss. This Quickstart Guide should be used in conjunction with the Instruction Manual that shipped with your instrument. Only necessary features to get you operational are discussed in this guide. Many of the advanced features of this analyzer are not described here so you should refer to the Instruction Manual to get the most from your analyzer. The Model 7600 NDIR Gas Analyzer measures the concentrations of NO, SO 2, CO 2, CO and CH 4 contained in a sample gas. The NO, SO 2, CO 2, CO and CH 4 components are measured by non-dispersion infrared method. The analyzer can be equipped with an internal paramagnetic O 2 sensor or use an external zirconia O 2 sensor to increase the number of measured components to 5. A maximum of 5 components including O 2 can be measured simultaneously. Front Panel (Operator Interface) Take a minute to familiarize yourself with the analyzer s interface. The standard 7600 NDIR Gas Analyzer is housed in a rugged NEMA-4 enclosure with controls and display accessible from the front panel. The operator interface consists of eight buttons for operating the analyzer, a display screen, plus power and back light switches. Teledyne Analytical Instruments 1

4 Quickstart Guide Control Keys: Name Description Name Description MODE key Used to switch the mode. ESC key Used to return to a previous screen or cancel the setting midway. SIDE key Used to change the selected item (by moving the cursor) and numeral digit. ENT key Used for confirmation of selected items or values, and for execution of calibration. UP key Used to change the selected item (by moving the cursor) and to increase numeral value. ZERO key Used for zero calibration. DOWN key Used to change the selected item (by moving the cursor) and to decrease numeral value. SPAN key Used for span calibration. Rear Panel At the rear panel you make the gas and electrical connections to the instrument. AC Power Inlet: Port for connecting power cable. Gas Connections: One inlet, one exhaust and a purge inlet. Teledyne Analytical Instruments 2

5 Model 7600 Quickstart Guide Input/Output Terminal Module: The input/output module is the electronic interface that handles the various signals to and from the analyzer. It consists of up to five terminal blocks, a communications connector, a cable connector, and a solenoid drive output connector mounted together on a single mounting plate. Refer to the Instruction manual that shipped with your instrument for a complete list of input/output signal connections handled through the Terminal Module. Teledyne Analytical Instruments 3

6 Quickstart Guide SETUP AND INSTALL Mount the Analyzer The Model 7600 is for indoor use. It is NOT explosion proof and should not be installed where explosive or flammable gases are present. For installation, select an indoor location that is vibration-free, clean, and close to an AC power source ( VAC 50/60 Hz). The instrument is designed for either a guide rail or slide rail mounting within a rack or cabinet. Whichever mounting method is chosen, make sure there is sufficient access room on top of the analyzer to be able to remove the top cover and perform instrument maintenance. Mount the Input/Output Terminal Module Mount the input/output terminal module to the rack or cabinet panel using the six M4 screws supplied. Teledyne Analytical Instruments 4

7 Model 7600 Quickstart Guide Gas Connections Note: Read all cautions contained in the Instruction manual before installing sample system. You will need the following calibration gases: Zero gas: N 2 (NO, SO 2, CO 2, CO, CH 4 and built-in paramagnetic O 2 sensor). Purge gas (N 2 or other inert gas) Span gas: 90% of full scale of component for analysis. Span gas: for built-in paramagnetic O 2 sensor 90% of full scale of O 2. If using an external zirconia O 2 sensor, you will need: Zero gas dry air or air Span gas 1-2% O 2 The analyzer is designed for 1/4 inch tubing. Installed fittings are 1/4 NPT. A typical piping diagram is shown below. This diagram shows calibration gases directed to the analyzer through solenoid valves which are controlled by the analyzer. There are several ways to bring sample gas to the analyzer depending on the number of inlet/outlet gas connections on your instrument. Refer to Section 2.2 in the Instruction Manual for other configurations. 1. Connect the sample gas to the SAMPLE IN port. 2. Connect a vent line to SAMPLE OUT port. Exhaust to atmospheric pressure. 3. Calibration gases should be tee'd into the sample inlet with appropriate valves. (See piping diagram). 4. Regulate the sample gas pressure to keep the sample flow around 0.5 liter/min ± Use short tubing with minimum bends for improved response time. 6. If required, connect a purge gas to the purge inlet. Use a purge flowrate of 1 lpm. Note: Exhaust connections must be consistent with the hazard level of the constituent gases. Check Local, State, and Federal laws, and ensure that the exhaust stream vents to an appropriately controlled area, if required. 7. Use a flowrate of 0.5L/min ±0.2L/min. Your sample system should be designed to avoid any flow fluctuation during measurement. A flowmeter should be installed to observe the flow reading as shown in the piping diagram below. Teledyne Analytical Instruments 5

8 Quickstart Guide Electrical Connections CAUTION: READ ALL SAFETY INFORMATION REGARDING ELECTRICAL HAZARDS ASSOCIATIED WITH THIS INSTRUMENT BEFORE MAKING ELECTRICAL CONNECTIONS. All electrical connections are made at the rear panel. The Model 7600 requires VAC 50/60 Hz AC power for operation. 1. Main Power: Connect primary input power cord. Insert the power cord into the power cord receptacle. 2. I/O Module Cable: Connect the cable from the I/O Module to the rear panel of the analyzer. The I/O Module carries various input and output signals. A detailed list of these signals and pinout information is given in the Appendix of the Instruction Manual. Teledyne Analytical Instruments 6

9 Model 7600 Quickstart Guide BASIC OPERATION After the analyzer has been installed with gas and electrical connections but prior to powering up the unit make sure you have: Installed the unit correctly Checked the gas connections for leaks Once the above checks have been made, you can connect the power source and turn the analyzer on using the power switch on the front panel. Allow the analyzer to warm up for four hours. When the instrument is first turned on, you will see the measurement screen. While in the warm up stage, the readings are inaccurate. They may even be above the upper limit of range, however, this is not an error. After the analyzer has come to equilibrium (approximately four hours after first powering up) the instrument is ready to be configured and calibrated for your process. Prior to using the instrument you must: Turn the power on and allow the analyzer to warm up. Select the range for analysis. Enter calibration parameters. Set alarm setpoints. Calibrate the instrument. Additional configuration parameters are available to tailor the instrument to your particular application. Refer to the Instruction Manual for specific information on setting of additional system parameters. Modes of Operation There are three basic modes of operation, Measurement mode, User mode and Calibration mode. Measurement mode is the default mode and is where you view the concentration data, alarm information and other data and messages relating to the analysis. The measurement mode shown in the Figure to the right, displays up to 5 channels in a Teledyne Analytical Instruments 7

10 Quickstart Guide single screen. When viewing a channel beyond the 5 channels, press the UP or DOWN keys to scroll the screen one channel at a time. The User mode, is where you will setup the parameters for analyzer. It is entered by pressing the MODE key which toggles between Measurement and User modes. Note that in the User mode screen, the upper left portion of the screen indicates the particular screen you are viewing while the upper right portion prompts you for the possible inputs within the screen. The Calibration Mode is used for calibrating the analyzer. It is entered from the Measurement mode by pressing either the ZERO or SPAN keys. This mode is used to set zero and span calibration concentration, calibration range and auto-calibration details. But before you can calibrate the analyzer there are some parameters to set up first, and these are discussed below. Warm-Up Operation and Regular Operation 1. Turn ON the power switch at the left of the front panel. In a few moments, the measurement screen will appear at the front panel. 2. Allow 2 hours for the instrument to warm-up. Selecting the Analysis Range Select the analysis range for each component. For this procedure, use manual range selection as follows: 1. Press the MODE key to display the User mode. 2. Point the cursor to Range Change and press the ENT key. The Channel Selection screen appears. Press the UP or DOWN key to select the desired CH (component). Then press the ENT key. There are 3 range switch modes in the second column to select from: MR: RR: AR: Manual selection Remote range switch Autoranging Teledyne Analytical Instruments 8

11 Model 7600 Quickstart Guide The selected range switch mode is highlighted for the channel you selected. 3. Press the UP/DOWN keys to select Manual Selection (MR). Then press the ENT key to confirm the selection. 4. Move the highlight of the cursor to range selection and select the desired range using the UP/DOWN keys. The highlighted arrow indicates the currently selected range. 5. Press ENT to accept the selection. Measurement is now carried out using the selected range. Note: If RR or AR is selected as range switch mode, manual range selection as described above is not possible Calibration Settings Set calibration concentration: Here, you will set the concentration of the standard gas (zero and span) for each channel that will be used in calibration. 1. Press the MODE key and toggle the display to the User mode. 2. Use the UP or DOWN keys to point the cursor to Calibration Parameters. Press the ENT key. 3. In the Setting about Calibration screen that appears, move the cursor to Calibration Value using the UP or DOWN key. Press the ENT key. 4. The next screen prompts you to select the channel you want to set. Move the cursor to the channel (CH) you want using the UP or DOWN key. Press the ENT key. 5. Select any concentration item you want to set using the UP, DOWN, or SIDE key. Note: Only instruments using the zirconia O 2 sensor can alter the zero setting. Teledyne Analytical Instruments 9

12 Quickstart Guide 6. Enter the calibration gas concentration values (zero and span) using the UP or DOWN key to increase or decrease the displayed value. Move to the next digit by pressing the SIDE key. When the correct calibration value is shown, save the entry by pressing the ENT key. 7. To close the calibration concentration value setting process or abort the entry midway, press the ESC key. A previous screen will return. Manual zero individually or all at once: Here you will set whether you want to zero calibrate all components at once or individually channel by channel. 1. Press the MODE key and toggle the display to USER mode. 2. Move the cursor to Calibration Parameters using the UP or DOWN key. Press the ENT key. 3. In the next screen use the UP or DOWN key to move to About ZERO Calibration. Press the ENT key. 4. In the next screen, point the cursor to CH you want to set by using the UP or DOWN key. Press the ENT key. 5. In the next screen, select At once or Each by pressing the UP or DOWN key. Selecting At once will allow the CH (components) to be zerocalibrated at the same time. Selecting Each allows the CH (components) to be individually zerocalibrated. After setting, press the ENT key to save the selections. 6. To close the calibration screen or abort the entry midway, press the ESC key. A previous screen will return. Set the Range to Calibrate on: This mode is used to set the range for each CH (component) to calibrate on. You can calibrate the component on a single range or both ranges. 1. Press the MODE key to display the User mode. Teledyne Analytical Instruments 10

13 Model 7600 Quickstart Guide 2. Move the cursor to Calibration Parameters using the UP or DOWN keys. Press the ENT key. 3. In the next screen that appears, select About Calibration Range using the UP or DOWN keys then press the ENT key. 4. In the next screen, select the CH you want to set by pressing the UP or DOWN keys. Press the ENT key. 5. In the Calibration Selection screen that appears, select Both or Current by pressing the UP or DOWN key. When selecting both, Range 1 and Range 2 of the set CH are calibrated together. When selecting Current, the single range selected at the set CH is calibrated. 6. To close the calibration screen or abort midway, press ESC. Enabling Auto Calibration: Here you can set which components are automatically calibrated. It is assumed that for the procedures listed in this Quickstart Guide, Auto Calibration is disabled and calibration is performed manually. To make sure of the correct setting: 1. Press the MODE key to display the User mode. 2. Point the cursor to Setting about Calibration using the UP or DOWN key. Press the ENT key. 3. In the next screen, point the cursor to Auto Calibration Components using the UP or DOWN key. Press the ENT key. 4. In the next screen, move the cursor to the CH you want to set using the UP or DOWN key. Press the ENT key. 5. In the Auto Calibration Selection screen that appears, select enable or disable by pressing the UP or DOWN key. For the Quickstart procedure, make sure all components are set to DISABLE. After setting, press the ENT key. Enable will allow that channel to be calibrated using the Auto Calibration feature. 6. To close the auto calibration screen or abort midway, press ESC to return to a previous menu. Teledyne Analytical Instruments 11

14 Quickstart Guide Note: Any component set to enable will be calibrated to zero at once at the time of auto calibration regardless of setting chosen in Manual Zero Individually or At Once. To setup and use the Auto Calibration feature, refer to the Instruction manual shipped with your instrument. Setting Alarms Prior to using the analyzer, you should set the alarm upper and lower limit values to provide an alarm output during measurement.. High/low alarms are available for each channel. The setting range is 0-100% full scale for each range. Note: The alarms are inactive for 10 minutes after turning on power. 1. Press the MODE key to display the User mode. 2. Point the cursor to Alarm Setting using the UP or DOWN key, then press the ENT key. 3. In the Alarm Setting screen that appears, point the cursor to the alarm number you want to set (1 through 6) using the UP or DOWN key. Press the ENT key when the cursor is on the alarm number you desire. 4. The alarm item selection screen will appear where you can select the alarm type, assign it to a channel, define setpoints, and enable or disable the alarm. Use the UP or DOWN keys until the cursor is aligned with the desired function and press the ENT key. Note: Before changing the alarm setting, set the ON/OFF to OFF Note: Set the values so that upper limit value > lower limit value and that (upper limit value - lower limit value) > hysteresis error. (Refer to the Instruction Manual for setting or displaying the hysteresis error.) 5. Move the cursor to the item to adjust or set and use the UP or DOWN key to increase or decrease the alarm setpoint value. Move to the next digit by pressing the SIDE key. When the correct alarm setpoint is shown, save the entry by pressing the ENT key. Teledyne Analytical Instruments 12

15 Model 7600 Quickstart Guide H-Limit value: L-Limit value: ON/OFF: sets the upper limit value (concentration) of alarm. sets the lower limit value (concentration) of alarm. enables the alarm function when set to ON, or disables the alarm function when set to OFF. Note: The upper limit value cannot be set below the lower limit value, and the lower limit value cannot be set above the upper limit value. If it is desired to set the upper limit value below the lower limit value already stored in the memory, reduce the lower limit value first. 6. Use the ESC key to leave the Alarm Setting screen and return to the previous screen. Calibration Zero Calibration: 1. Make sure an appropriate zero gas is properly connected to your analyzer. (Refer back to Gas Connections if necessary). 2. Press the ZERO key to display the Manual Zero Calibration screen. 3. Select the CH (component) to be calibrated by pressing the UP or DOWN key. Then press the ENT key to initiate zero gas flow to the analyzer. Note: For all components that were set to at once in the Zero Calibration setting, the zero calibration will be carried out simultaneously. 4. After the display has stabilized (this may take a few moments), press the ENT key. Zero calibration in the range(s) indicated by the cursor will be performed. 5. To close the Zero Calibration or cancel this mode midway, press the ESC key to return to the previous screen. Span Calibration: 1. For span calibrating the CO 2, CO, CH 4, SO 2 and built-in paramagnetic O 2 sensor channels, use a standard gas with a concentration of 90% or more on the anticipated range. For an external zirconia O 2 sensor, use a standard gas of about 2 vol%. 2. Press the SPAN key to display the Manual Span Calibration screen. 3. Select the component to be calibrated by pressing the UP or DOWN keys. Then press the ENT key to initiate span Teledyne Analytical Instruments 13

16 Quickstart Guide gas flow to the analyzer.. Note: If the range to calibrate on has been set to both, span calibration is performed together on the 2 Ranges. 4. After the display has stabilized (this may take a few moments), press the ENT key. Span calibration on the component and range(s) indicated by the cursor will be performed. 5. To close the Span Calibration or cancel this mode midway, press the ESC key to return to the previous screen. Measurement Mode After calibration the Model 7600 will return to the Measurement mode and the instrument is now ready for operation. Teledyne Analytical Instruments 14

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments QUICKSTART GUIDE MODEL 7500 Teledyne Analytical Instruments Quickstart Guide Teledyne Analytical Instruments Model 7500 Quickstart Guide GETTING STARTED This Quickstart Guide is designed to get you set

More information

QUICKSTART GUIDE. Trace Oxygen Analyzer. Teledyne Analytical Instruments

QUICKSTART GUIDE. Trace Oxygen Analyzer. Teledyne Analytical Instruments QUICKSTART GUIDE MODEL 3000TA Teledyne Analytical Instruments Quickstart Guide Teledyne Analytical Instruments Model 3000TA Quickstart Guide GETTING STARTED This Quickstart Guide is designed to get you

More information

CDD4 Duct Carbon Dioxide Transmitter

CDD4 Duct Carbon Dioxide Transmitter Drill or punch a 1-1/8 or 1-1/4 hole in the duct at the preferred location and insert the probe into the hole to mark the enclosure mounting holes. Remove the unit and drill the four mounting holes. Clean

More information

Model IR400 Infrared Gas Analyzer (22) Sample gas inlet Rc1/4 or 1/4 NPT

Model IR400 Infrared Gas Analyzer (22) Sample gas inlet Rc1/4 or 1/4 NPT Drawings Model IR00 Infrared Gas Analyzer [Style: S] Slide rail (). Power Switch Sample gas inlet Rc1/ or 1/ NPT. M 100. 1 JIS : 100 mm EIA : 101.

More information

CDD Carbon Dioxide Transmitter

CDD Carbon Dioxide Transmitter Introduction The OSA CO2 transmitter uses Infrared Technology to monitor CO2 levels within a range of 0 2000 ppm and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. The enclosure is designed to operate

More information

CDD4 Series Room CO2 Transmitter Installation Instructions

CDD4 Series Room CO2 Transmitter Installation Instructions CDD4 Series Room CO2 Transmitter Installation Instructions Introduction The CO2 transmitter uses Infrared Technology to monitor CO2 levels and outputs a linear 4-20 ma or 0-5/0-10 Vdc signal. Options include

More information

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80 User Guide Indoor Air Quality Meter/Datalogger Model EA80 Introduction Congratulations on your purchase of the Extech EA80 Indoor Air Quality Meter. This meter measures Carbon Dioxide (CO 2, ppm) levels,

More information

Indoor Air Quality Meter/Datalogger

Indoor Air Quality Meter/Datalogger User Manual Indoor Air Quality Meter/Datalogger Model EA80 CC Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech EA80 Indoor Air

More information

PROCESS ANALYSERS. SERVOTOUGH FluegasExact Gas Analyser. QuickStart Manual. Part Number: D Revision: 1 Language: UK English

PROCESS ANALYSERS. SERVOTOUGH FluegasExact Gas Analyser. QuickStart Manual. Part Number: D Revision: 1 Language: UK English PROCESS ANALYSERS SERVOTOUGH FluegasExact Gas Analyser QuickStart Manual Part Number: 02700003D Revision: 1 Language: UK English This page intentionally blank TABLE OF CONTENTS 1. INTRODUCTION............................................

More information

Instruction Manual. Carbon Dioxide Analyzer

Instruction Manual. Carbon Dioxide Analyzer 410iQ Instruction Manual Carbon Dioxide Analyzer 117081-00 15Jan2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 410iQ Principle of Operation... 1-3

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

Formaldehyde Thermo-Hygrometer

Formaldehyde Thermo-Hygrometer User Manual Formaldehyde Thermo-Hygrometer Model FM200 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model FM200. The FM200

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

48iQ Instruction Manual. Carbon Monoxide Analyzer

48iQ Instruction Manual. Carbon Monoxide Analyzer 48iQ Instruction Manual Carbon Monoxide Analyzer 117080-00 27Sep2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 48iQ Principle of Operation... 1-3

More information

USER MANUAL Video Particle Counter with built in Camera Model VPC300

USER MANUAL Video Particle Counter with built in Camera Model VPC300 USER MANUAL Video Particle Counter with built in Camera Model VPC300 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model VPC300

More information

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230 P/N 0-027289 (Rev. A 04/4) NT PRESSURE TRANSDUCER MODELS 400, 420, 430, 4230 User Guide Table of Contents Safety Alert Symbol... 2 Introduction... 3 Installation... 3 Mechanical Installation... 3 Electrical

More information

Standard Operating Procedure

Standard Operating Procedure 1 of 7 Prepared by: Reviewed by: Approved by: Date: Date: Date: The colored ink stamp indicates this is a controlled document. Absence of color indicates this copy is not controlled and will not receive

More information

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000 Product Data Sheet PDS 103-610.A01 January, 2004 NGA 2000 Platform Modular design single platform supports multiple analyzer and Input/Output modules Local network with intelligent, bi-directional communication

More information

FOX-50 Heat Flow Meter

FOX-50 Heat Flow Meter FOX-50 Heat Flow Meter Site Preparation Guide Revision A Issued June 2016 Page 1 Table of Contents Table of Contents... 1 Ideal Setup... 2 System Components... 3 Instrument Measurements... 4 Utility Requirements...

More information

KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY

KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY KUHLMAN INSTRUMENT COMPANY 5000K WARRANTY The 5000K is warranted for one year against defects in material or workmanship. This warranty does not cover water or physical damage, damage from over pressure

More information

SDM-03 Docking Station Standalone Configuration Operator s Manual

SDM-03 Docking Station Standalone Configuration Operator s Manual SDM-03 Docking Station Standalone Configuration Operator s Manual Part Number: 71-0359 Revision: 0 Released: 2/1/16 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment sold

More information

Agilent Flowmeter ADM2000

Agilent Flowmeter ADM2000 Agilent Flowmeter ADM2000 Operating Instructions Notices Agilent Technologies, Inc. 2003 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

SDM-2009 Docking Station PC Controlled Configuration Operator s Manual

SDM-2009 Docking Station PC Controlled Configuration Operator s Manual SDM-2009 Docking Station PC Controlled Configuration Operator s Manual Part Number: 71-0262RK Revision: F Released: 12/12/17 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Carbon Monoxide (CO) Gas Detection and Control System

Carbon Monoxide (CO) Gas Detection and Control System Carbon Monoxide (CO) Gas Detection and Control System DESCRIPTION Gas monitor with built-in carbon monoxide (CO) sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature

More information

Thermal Diffusivity Instruments DLF-2 with EM-1600

Thermal Diffusivity Instruments DLF-2 with EM-1600 Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...

More information

42iQLS Instruction Manual

42iQLS Instruction Manual 42iQLS Instruction Manual Low Source NO-NO 2 -NO x Analyzer 117436-00 15Jan2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 Principle of Operation...

More information

49iQPS Instruction Manual. Ozone Primary Standard

49iQPS Instruction Manual. Ozone Primary Standard 49iQPS Instruction Manual Ozone Primary Standard 117434-00 27Sep2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 Principle of Operation... 1-3 Specifications...

More information

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51 Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1

More information

350 SMART MANOMETER OPERATING INSTRUCTIONS

350 SMART MANOMETER OPERATING INSTRUCTIONS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 350 SMART MANOMETER OPERATING INSTRUCTIONS Meriam Instrument s 350 Smart Manometer

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

OPERATION MANUAL MODEL 465L OZONE MONITOR

OPERATION MANUAL MODEL 465L OZONE MONITOR OPERATION MANUAL MODEL 465L OZONE MONITOR Teledyne Advanced Pollution Instrumentation (T-API) 9480 Carroll Park Road San Diego, CA 92121-5201 Phone: 800-324-5190 (toll free in North America) 858-657-9800

More information

353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS

353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS 353 PRECISION ALTIMETER TESTER OPERATING INSTRUCTIONS The Model 353 provides Altitude, Rate of Climb (R of C), and Leak testing at the stroke of a key. It is microprocessor based and its accuracy is ±

More information

MODEL 42C High Level

MODEL 42C High Level MODEL 42C High Level CHEMILUMINESCENCE NO-NO 2 -NO x ANALYZER INSTRUCTION MANUAL P/N 100175-00 THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038 (866)

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

SP6R Level Controller Operation Manual

SP6R Level Controller Operation Manual SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.

More information

MODEL 7100 OXYGEN ANALYZER / CONTROLLER TRACE RANGE OPERATIONS MANUAL

MODEL 7100 OXYGEN ANALYZER / CONTROLLER TRACE RANGE OPERATIONS MANUAL Engineered Solutions for Gas Detection and Analysis High Purity Instruments MODEL 7100 OXYGEN ANALYZER / CONTROLLER TRACE RANGE OPERATIONS MANUAL NTRON MODEL 7100 O 2 Analyzer TRACEOXYGEN SENSOR 20 RUN

More information

QUICKSTART INSTALLATION INSTRUCTIONS

QUICKSTART INSTALLATION INSTRUCTIONS WEGENER i8640 DIGITAL AUDIO SERVER QUICKSTART INSTALLATION INSTRUCTIONS This satellite receiver has been provided for the reception of MRN, WestwoodOne or Compass Sports. Once installed, please contact

More information

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours! Data sheet MK 20 GR Customized solution or off-the-shelf: The choice is yours! MK20-GR data sheet Looking for a quick and reliable solution? Then rely on our standard products: Our universal controls provide

More information

SDM-2012 Docking Station PC Controlled Configuration Operator s Manual

SDM-2012 Docking Station PC Controlled Configuration Operator s Manual SDM-2012 Docking Station PC Controlled Configuration Operator s Manual Part Number: 71-0256RK Revision: C Released: 8/12/13 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T READ THESE INSTRUCTIONS BEFORE YOU BEGIN INSTALLATION LOCATION The I/CO 2 transmitter is designed to mount over a standard single

More information

XARTU/TP Transfer Prover Manual Copyright 2014 Eagle Research Corporation Page 2

XARTU/TP Transfer Prover Manual Copyright 2014 Eagle Research Corporation Page 2 XARTU/TP Transfer Prover Manual Copyright 2014 Eagle Research Corporation Page 2 Table of Contents Transfer Prover Operation... 4 Materials/Tools Needed... 4 Assembly Steps:... 4 1. Prepare the site....

More information

Model DT3008. Extractive Combustibles Monitor

Model DT3008. Extractive Combustibles Monitor Model DT3008 Extractive Combustibles Monitor Type 1: 0 to 10 % Version 1.00 Job Specific Information The check marks below denote the equipment configuration that has been supplied to the following installation:

More information

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer Model: 92000-01 THE STANDARD IN PRECISION MEASUREMENT Table of Contents Introduction... 3 Unpacking... 3 Initial Setup...3

More information

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide

FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide Fisher FIELDVUE DVC6200 and DVC6200f Digital Valve Controller Management of Change Guide 2011 Fisher Controls International LLC. All rights reserved. MY30 (H:) TABLE OF CONTENTS Background... 3 Management

More information

SDM-E2 Docking Station Standalone Configuration Operator s Manual

SDM-E2 Docking Station Standalone Configuration Operator s Manual SDM-E2 Docking Station Standalone Configuration Operator s Manual Part Number: 71-0224RK Revision: F Released: 5/16/17 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2200) Operator Manual. Part Number: 02210/001A Revision: 4 Language: UK English

PROCESS ANALYSERS. SERVOTOUGH OxyExact (2200) Operator Manual. Part Number: 02210/001A Revision: 4 Language: UK English PROCESS ANALYSERS SERVOTOUGH OxyExact (2200) Operator Manual Part Number: 02210/001A Revision: 4 Language: UK English This page intentionally blank xendos 2200 Operator Manual Ref: 02210/001A/4 Order as

More information

Pneumatic Precision Pressure Controller Model CPC6000

Pneumatic Precision Pressure Controller Model CPC6000 Calibration Technology Pneumatic Precision Pressure Controller Model CPC6000 R WIKA Data Sheet CT 27.61 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration

More information

SDM-03 Docking Station PC Controlled Configuration Operator s Manual

SDM-03 Docking Station PC Controlled Configuration Operator s Manual SDM-03 Docking Station PC Controlled Configuration Operator s Manual Part Number: 71-0360 Revision: C Released: 12/12/17 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology

VVP10-H HART VALVE POSITIONER. Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol. Electronic Coil Technology VVP10-H HART VALVE POSITIONER Great Performance, Compact, Robust in Severe Conditions* HART 7 Communication Protocol Electronic Coil Technology Non-Contact Position Sensor (Hall Sensor) 4-20 ma NAMUR NE

More information

Continuous gas analysis

Continuous gas analysis Oxygen analyzer for standard applications 7MB2001 Operating instructions Continuous gas analysis General information 1 Description 2 Continuous gas analysis Oxygen analyzer for standard applications Operating

More information

Specifications - Installation and Operating Instructions. Duracell is a registered trademark of The Gillette Company.

Specifications - Installation and Operating Instructions. Duracell is a registered trademark of The Gillette Company. Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions The Series DM-1000 DigiMag Digital Differential Pressure Gage is the

More information

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical

EE80 Series. HVAC Room Transmitter and Switches for CO 2, Relative Humidity and Temperature EE80. Applications. Typical EE80 Series HVAC Room Transmitter and Switches for, Relative Humidity and Temperature EE80 series set new standards in measurements for HVAC. The transmitters resp. switches combine, relative humidity

More information

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X R Calibration Technology High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X WIKA Data Sheet CT 28.01 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture

More information

42iQD Instruction Manual

42iQD Instruction Manual 42iQD Instruction Manual NO x Analyzer 119013-00 27Sep2018 Contents Chapter 1 Chapter 2 Chapter 3 Introduction... 1-1 iq Series Instrument Platform... 1-1 Principle of Operation... 1-3 Specifications...

More information

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062

Installation Guide. Carbon Dioxide (CO 2. ) Detectors. General Information. Mounting WARNING CAUTION. SAE-1011/1012 Space Mount SAE-1011/1012/1062 General Information WARNING Do not use in an explosive or hazardous environment, with combustible or flammable gases, as a safety or emergency stop device, or in any other application where failure of

More information

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012 ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,

More information

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE Thank you for purchasing a TSI AeroTrak Portable Airborne Particle Counter (particle counter). This guide will

More information

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description RAD-0501 Greenhouse Mode: Controls CO2 generator or regulator to increase CO2 levels during daylight

More information

Model 8732 IAQ-CALC TM Indoor Air Quality Meter

Model 8732 IAQ-CALC TM Indoor Air Quality Meter Indoor Air Quality Model 8732 IAQ-CALC TM Indoor Air Quality Meter Operation and Service Manual 1980393, Revision D October 2004 Model 8732 IAQ-CALC TM Indoor Air Quality Meter Operation and Service Manual

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

INSTRUCTION MANUAL MODEL 465M OZONE MONITOR

INSTRUCTION MANUAL MODEL 465M OZONE MONITOR INSTRUCTION MANUAL MODEL 465M OZONE MONITOR 2007 Teledyne Advanced Pollution Instrumentation (T-API) 9480 Carroll Park Drive San Diego, CA 92121-5201 TOLL-FREE: 800-324-5190 TEL: 858-657-9800 FAX: 858-657-9816

More information

Rosemount 370XA Natural Gas Chromatograph

Rosemount 370XA Natural Gas Chromatograph Quick Start Guide NGC-QSG-370XA February 018 Rosemount 370XA Natural Gas Chromatograph Quick Start Guide Typical Installation Minimum Specifications Safety First. Before You Start 1 3 370XA Natural Gas

More information

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual 621 Hunt Valley Circle New Kensington, PA 15068 3015-5547 Tel: 724-334-5000 Revision 4 Fax: 724-334-5001 May 17, 2013 Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

More information

Micro GC Fusion Quick Start Guide

Micro GC Fusion Quick Start Guide Micro GC Fusion - Quick Start Guide Micro GC Fusion Quick Start Guide 1 This quick start guide is designed to instruct the user on the steps required to install Micro GC Fusion and assumes the user is

More information

Data Cal 2000 Operator s Manual

Data Cal 2000 Operator s Manual Data Cal 2000 Operator s Manual Part Number: 71-0097RK Revision: C Released: 9/13/10 RKI Instruments, Inc. Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects

More information

DPL4000 Portable Low Range Dew Point Analyzer

DPL4000 Portable Low Range Dew Point Analyzer OPERATIONS MANUAL DPL4000 Portable Low Range Dew Point Analyzer 7205 Edington Drive / Cincinnati, OH 45249 / Tel (513) 772-0060 / Fax (513) 772-9466 Page #1 of 16 M4581 DPL4000 Product Description: This

More information

SDM-6000 Docking Station Standalone Configuration Operator s Manual

SDM-6000 Docking Station Standalone Configuration Operator s Manual SDM-6000 Docking Station Standalone Configuration Operator s Manual Part Number: 71-0385 Revision: P3 Released: 4/18/16 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter

MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter MST2000 Loop Powered Multivariable SMARTFLOW Transmitter Brandt Instruments MST2000 Series Loop Powered Multivariable SMARTFLOW Transmitter sets

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY

Omni. User Manual. Economic Self-Tune PID Temperature Controller. Omni 96. Omni 72 72X72. Omni ~ 265 V AC SUPPLY Omni Economic Self-Tune PID Temperature Controller Omni 7 Omni 4 6 5 4 3 1 7X7 7 1 11 5 ~ 65 V AC SUPPLY Omni 6 CONTENTS 1. PANEL MOUNTING & ELECTRICAL CONNECTIONS 1. FRONT PANEL : LAYOUT AND OPERATION

More information

Software Manual. MLT Analyzer. MLT Analyzer Module

Software Manual. MLT Analyzer. MLT Analyzer Module Rosemount Analytical NGA 2000 Software Manual MLT Analyzer MLT Analyzer Module (combined with NGA 2000 platform / MLT analyzer / TFID analyzer or customer-developed control unit) Software Version 3.3.X

More information

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FORM 31003-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS PRESSURE CONTROL OPTION WITH ECM MOTORS CARNES COMPANY 448 S. Main St., P. O. Box 930040, Verona, WI 53593-0040 Phone: (608)845-6411 Fax:

More information

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial

More information

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.

More information

Meta-Press. Porcelain Pressing Furnace. Quick Start Instructions & Reference Manual

Meta-Press. Porcelain Pressing Furnace. Quick Start Instructions & Reference Manual Meta-Press Porcelain Pressing Furnace Quick Start Instructions & Reference Manual Meta-Press Porcelain Pressing Furnace Quick Start Instructions & Reference Manual INSTRUCTIONS AND REFERENCE MANUAL QUICK

More information

High-end pressure controller Model CPC8000

High-end pressure controller Model CPC8000 Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration

More information

MyGenie TM 32 Thermal Block

MyGenie TM 32 Thermal Block User s Guide MyGenie TM 32 Thermal Block A-2030-4 MyGenie TM 32 Thermal Block User s Guide Version No.: 1.1 (2013-05) Please read all the information in booklet before using the instrument Bioneer 8-11,

More information

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring

MCS 100 E. Compact IR Photometer for Stack Gas Monitoring P R O D U C T I N F O R M A T I O N MCS 100 E Compact IR Photometer for Stack Gas Monitoring Modern Emission Measuring Technology: Compact Stack Gas Monitoring The MCS 100 E is an extremely compact multi-component

More information

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company

Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company Design and Manufacture of Video Pipeline Inspection Systems A Full Service Company www.rstechserv.com Omni Star LED Pan and Tilt Zoom Color Camera Modell 10-1660 INSTALLATION MANUAL Made in USA IMPORTANT

More information

Polytron 2 XP Ex. Transmitter for Catalytic Combustion Sensors. Operating Manual

Polytron 2 XP Ex. Transmitter for Catalytic Combustion Sensors. Operating Manual Polytron 2 XP Ex Transmitter for Catalytic Combustion Sensors Operating Manual For Your Safety For Your Safety Strictly follow the assembly and installation instructions Any use of the transmitter requires

More information

Pneumatic precision pressure controller Model CPC6000

Pneumatic precision pressure controller Model CPC6000 Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers

More information

Rosemount 928 Wireless Gas Monitor

Rosemount 928 Wireless Gas Monitor August 2018 Quick Start Guide Rosemount 928 Wireless Gas Monitor Integrated Wireless Gas Monitoring NOTICE This guide provides configuration and basic installation information for the Rosemount TM 928

More information

CO Analyzer. The Value Leader TM

CO Analyzer. The Value Leader TM CO Analyzer 707 The Value Leader TM www.tpi-thevalueleader.com Contents Specifications Product Features Standard Accessories Optional Accessories General Description Operating Instructions Battery Replacement

More information

Pneumatic High-Speed Pressure Controller Model CPC3000

Pneumatic High-Speed Pressure Controller Model CPC3000 Calibration Technology Pneumatic High-Speed Pressure Controller Model CPC3000 02/2014 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration service companies

More information

Industrial pressure controller Model CPC4000

Industrial pressure controller Model CPC4000 Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series 59 Individual mounting Series inline 35 100 Ext. pilot port Accumulator EXH. Pilot valve Function plate From accumulator Pilot exhaust To accumulator

More information

Operations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System

Operations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System Operations Manual HP2000 With 9100 Controller Self-Heated Oxygen Measurement System Please read, understand, and follow these instructions before operating this equipment. Super Systems, Inc. is not responsible

More information

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK

Proximity Positioner. ICoT. Valve Monitoring and Control Products WESTLOCK Proximity Positioner UNLIKE CONVENTIONAL POSITIONERS, THE ICOT POSITIONER FEEDS BACK VALVE POSITION WITHOUT THE NEED FOR LINKAGES OR LEVERS. Non-contact position feedback is accomplished through the use

More information

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF Instruction Manual Model 2082-1972 Power Supply July 2012, Rev. B MODEL 2082 POWER SUPPLY CROSS TECHNOLOGIES INC. PRIMARY PWR AC BUC +48V AUX BUC TX SELECT 48V +18V/48V LNB RX +18V ANT CNTR +29V AC 18V

More information

OZONE SWITCH Model OS-6. OS-6 Features

OZONE SWITCH Model OS-6. OS-6 Features USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.

More information

KNC Model 3719 Air Data Test Set

KNC Model 3719 Air Data Test Set KNC Model 3719 Air Data Test Set Product Description The Model 3719 Air Data Test Set by King Nutronics Corporation is a highly accurate microprocessor-driven pressure calibrator designed to provide regulated

More information

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM

AccuTank ULTRASONIC LEVEL MONITORING SYSTEM AccuTank ULTRASONIC LEVEL MONITORING SYSTEM FLO-CORP s AccuTank Ultrasonic Level Monitoring System is the most economical, reliable and accurate remote monitoring system on the market. This affordable

More information

Integrated Valvejet 18 Dot Print Head. What am I getting? What are the improvements?

Integrated Valvejet 18 Dot Print Head. What am I getting? What are the improvements? Integrated Valvejet 18 Dot Print Head What am I getting? What are the improvements? Diagraph is proud to release the new IV18 Dot print head. New features include: Environmentally Sealed housing for harsh

More information

EATON Transformer Module

EATON Transformer Module www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC. 86-86000-0

More information

SDM-E2 Docking Station PC Controlled Configuration Operator s Manual

SDM-E2 Docking Station PC Controlled Configuration Operator s Manual SDM-E2 Docking Station PC Controlled Configuration Operator s Manual Part Number: 71-0251RK Revision: I Released: 7/10/18 www.rkiinstruments.com Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information