1 Avenir & kick Powerway System Flag Color -3-Circuit, Shared Neutral and System Ground (SHN) -4-Circuit, 3 with Shared Neutral and System Ground and 1- Isolated Circuit and Ground (3+D) (18" & 24" ONLY) (ALL OTHER LENGTHS) Optional Wiring Schematics: System Flag Color -2-General Circuits with Shared Neutral & System Ground and 2-Isolated circuits with Shared Neutral and Isolated Ground (2+2) Grey -3-Separate Circuits - 2 with own Neutral and Isolated Ground, 1 with own Neutral and System Ground (SPN) -4-Circuit - 3 with Shared Neutral and Isolated Ground, 1-Circuit with System Ground (3I+1) Tan 3/16" Socket If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE ( ) for immediate action by people who want to help you. (Outside the U.S.A., Canada, Mexico, Puerto Rico, and the U.S. Virgin Islands, call: ) Or visit our website: Steelcase Inc. Grand Rapids, MI U.S.A. Printed in U.S.A. WARNING: ALL ELECTRICAL INSTALLATIONS SHOULD BE PERFORMED BY A QUALIFIED PERSON IN ACCORDANCE WITH CODES AND REGULATIONS APPLICABLE AT THE INSTALLATION SITE. CIRCUITS SHOULD BE CHECKED FOR PROPER VOLTAGES Page 1 of 7

2 Wiring Schematic Powered by Separate Panels Powered by Single Panels / Letters SHARED SYSTEM L-1, and L-2 must be connected to different phases. L-3 and L-4 must be connected to different phases. / Letters /Yellow SHARED ISOLATED / Letters / Letters /Yellow SHARED SHARED SYSTEM L-1, L-2, & L-3 are connected to P-1, P-2 & P-3 respectively. L-4 is connected to P-1 or P-2 only and not to the same phase as L-3. 3 Circuit, Separate Neutrals Powered by Separate Panels 3 Circuit, Separate Neutrals Powered by Single Panels LINE A LINE B LINE A LINE B LINE C LINE C / Letters /Yellow / Letters LINE A LINE B A B ISOLATED LINE C C SYSTEM / Letters / Letters /Yellow LINE A LINE B LINE C A B C ISOLATED SYSTEM WARNING: Risk of Fire or Electric Shock: This office furnishing system may be connected to more than one source of supply. All sources must be disconnected prior to any servicing. No single circuit may be powered by more than one source. ELECTRICAL DATA: 125 V 60 HZ 20 Amp USA/CANADA 208Y/120 VAC 3-Phase Service 250/125 VAC 1-Phase Service Wiring schematics must be followed to prevent overloading of the neutrals. Page 2 of 7

3 Wiring Schematic 3+D - Powered by Separate Panels 3+D Powered by Single Panel /Yellow SHARED SYSTEM ISOLATED L-4 may be connected to P-1, P-2, or P-3 /Yellow SYSTEM ISOLATED L-4 should alternate between P-1, P-2, and P-3 to balance circuit loading. 3I+1 - Powered by Separate Panels 3I+1 - Powered by Single Panel ELECTRICAL DATA: 125 V 60 HZ 20 Amp USA/CANADA 208Y/120 VAC 3-Phase Service 250/125 VAC 1-Phase Service Wiring schematics must be followed to prevent overloading of the neutrals. / Letters /Yellow / Letters SHARED ISOLATED SYSTEM L-4 may be connected to P-1, P-2, or P-3 / Letters / Letters /Yellow SHARED SYSTEM ISOLATED L-4 should alternate between P-1, P-2, and P-3 to balance circuit loading. WARNING: 3 Circuit, Shared Neutral 3 Circuit, Shared Neutral Powered by Split Phase Panel Risk of Fire or Electric Shock: This office furnishing system may be connected to more than one source of supply. All sources must be disconnected prior to any servicing. No single circuit may be powered by more than one source. SHARED SYSTEM P-1 P-2 SHARED SYSTEM L-3 must be omitted or connected to the load side of L-1 or L-2. Page 3 of 7

4 Factory Installed Avenir Powerway 1. When installing panels with factory installed powerways, it is important to locate the yellow tape on the base trim. The yellow tape must always be on your right side as you face the panel. This will insure proper powerway to powerway connections after assembling your panels. KNOCKOUT BASE TRIM RETAINER SPRING YELLOW TAPE 2. To install a powerway into a panel remove the base trim and attach with (2) nuts (provided). FLAG CONNECTOR Field Installed Avenir Powerway NUT 60" powerway only. Factory & field installation. Mount powerway using 'A' portion of slot. WHIP LOCATION K A Page 4 of 7

5 Factory Installed kick Powerway 1. When installing panels with factory installed powerways, it is important to locate the yellow tape on the base trim. The yellow tape must always be on your right side as you face the panel. This will insure proper powerway to powerway connections after assembling your panels. KNOCKOUT BASE TRIM RETAINER SPRING YELLOW TAPE 2. To install a powerway into a panel remove the base trim and attach with (2) nuts (provided). FLAG CONNECTOR Field Installed kick Powerway NUT 60" powerway only. Factory & field installation. Mount powerway using 'K' portion of slot. WHIP LOCATION K A Page 5 of 7

6 Powerway to Powerway Connections 1. Before starting this step, refer to Steelcase Installation Directions for Avenir basic panel assembly and for kick basic panel assembly. 2-WAY JUNCTION To make powerway to powerway connection, push flag end into the predetermined J-connector. The electrical power (Base Power-in or Power Pole) location must be known prior to installing the powerway. INLINE JUNCTION 4-WAY JUNCTION 3-WAY JUNCTION END-OF-RUN JUNCTION Page 6 of 7

7 In-line Junction 3-way Junction 4-way Junction STORAGE End of Run Page 7 of 7

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers

Answer Modular Power. Page 1 of Rev V. Power Kits. Change of Height Harness. Receptical Covers Answer Modular Power Change of Height Harness Power Kits Receptical Covers NOTE: Unused modular electrical connector openings are not required to be capped. NOTE: The electrician can cut conduit and wire

More information

Installing Simplex and Duplex Receptacles into: Series 9000 Structural Panel Series 9000 Energy Management Panel and Worksurface Avenir Power Panel

Installing Simplex and Duplex Receptacles into: Series 9000 Structural Panel Series 9000 Energy Management Panel and Worksurface Avenir Power Panel If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.322) for immediate action by people who want to help you. (Outside the U.S.A., Canada,

More information

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions If you have a problem, question, or request, call your local dealer, or Steelcase Line 1 at 888.STEELCASE (888.783.3522) for

More information

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Modular Table Power System Installation for Runner Non-folding Plug and Play Tables Topic General Safety Warnings Ganging Hardware Electrical Circuits Table of Contents Page End-to-End (Page 4) End-and-Back

More information

Virtual PUCK for media:scape Kiosk and Answer

Virtual PUCK for media:scape Kiosk and Answer Virtual PUCK for media:scape Kiosk and Answer Note: For VP for media:scape on Kiosk, see page. For VP for media:scape on Answer, see page. # PHILLIPS /6" HEX DRIVE /6", /8" (all tables) plus 5/" (attached

More information

V.I.A. - Monitor Shroud

V.I.A. - Monitor Shroud V.I.A. - Monitor Shroud NOTE: Installing slatwall above a monitor shroud requires modification of the upper horizontal rail. See V.I.A. Slatwall assembly direction 939502328 for installation process. V.I.A.

More information

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2 RF Home Automation ZRF113 Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2 Note: This module must be Included in the Network only where it will

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist. CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control

More information

Installation Instructions & User Manual

Installation Instructions & User Manual Installation Instructions & User Manual ZONEMASTER PRO AC Panel Transient Voltage Surge Suppressors The Wiremold Company In US: 60 Woodlawn Street, West Hartford, CT 06110 800-621-0049 FAX 860-232-2062

More information

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE

CHANNEL LETTER LIGHTING UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS LIGHTING WARNING -Installation must only be performed by a licensed electrician. -To prevent death, injury or damage to property this product must be installed in accordance to

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit Important Safety Messages SAVE THESE INSTRUCTIONS - This section contains important instructions that should be followed during installation

More information

ETC Installation Guide

ETC Installation Guide Unison Foundry Overview The Unison Foundry provides fully-rated 20A relays for switched power control with 0 10V dimming for compatible fluorescent ballasts and LED drivers. The provides two outputs of

More information

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual

STC7D. Digital Time Clock for TRC500 & TRC800. Installation, Operation, and Maintenance Manual STC7D Digital Time Clock for TRC500 & TRC800 Installation, Operation, and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation

More information

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs) Models beginning with 2M, 2L or 2X Series 2000 Multiple Meter Units (MMUs) Product Description Technical Specifications Installation Instructions February 28 th, 2013 List of Figures...2 List of Tables...2

More information

PV Rapid Shutdown device

PV Rapid Shutdown device PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate AVR Manual Audio / Video Power Isolation Units with Automatic Voltage Regulation 19 Pro Series Rack Mount (RM) Faceplate Isolate. Restore. Inspire! 17 Consumer Series (CS) Faceplate Available in Black

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch PD52 PD52S & PD52DCS PD53-100 te: The PD52S & PD52DCS are provided with LED lights. The GREEN LIGHTS indicate Shore Power

More information

Rack Mount Power Supplies

Rack Mount Power Supplies Rack Mount Power Supplies Installation Guide Models Include: VertiLine33D - 12VDC @ 8A - Sixteen (16) PTC protected outputs VertiLine33TD - 12VDC @ 16A - Sixteen (16) PTC protected outputs VertiLine63D

More information

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS

SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS SPECIAL INSTRUCTIONS FOR CAPACITORS COMPACT GENERATORS (WITH CAPACITOR CHARGER BOARD A3517-02) The process depends on Generator and System configuration. This document applies to installation of Capacitors

More information

Power/Data Instructions. Genius. Movable Walls. September

Power/Data Instructions. Genius. Movable Walls. September Power/Data Genius Movable Walls September 2011 Genius Movable Walls Power and Data in Shell Level 1 Conventional Boxes in Panel (conventional box and conduit) Choose 2x4 box or 4x4 box (shown). Separate

More information

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents. User Guide CPSMP-205 110 240 VAC Power Supply Module: PointSystem CPSMC1800-200 Accessory CPSMC1900-100 Accessory Contents Contents...1 Description...1 Cautions and Warnings...2 Definitions...2 Power supply

More information

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions

RCD Fused Connection Unit Model: RCD10WPV. RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV. Installation & Operating Instructions RCD Fused Connection Unit Model: RCD10WPV RCD Double Sockets Models: RCD05WAV, RCD06WPV, RCD07MAV, RCD08MPV Installation & Operating Instructions General The Timeguard range of RCDs provides protection

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers) Instructions (For 6180 Industrial Computers) This document describes how to remove or install a Pentium processor in the 6180 Industrial Computer. Processor specifications are also provided. The processor

More information

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV OVERVIEW The STR9 ELV is a long run, low power, linear surface mount LED lighting system designed for exterior architectural lighting applications. This guide contains important information on planning

More information

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions. ProcessLine analogue module AC / / 2012 Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...

More information

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I) SwitchLinc Lite Remote Control Dimmer Switch Owner s Manual For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I) CONGRATULATIONS! You ve just purchased the highest quality powerline-controllable

More information

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016

Safegard V4 Panel. Installation Datasheet. Safegard V4 Panel Installation Instructions and Datasheet release 1.7 August 2016 Safegard V4 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product will directly

More information

Quick Reference Guide

Quick Reference Guide DSS Console Quick Reference Guide Model No. KX-T7740 Important Information When using the KX-T7740, keep the following in mind. If there is any trouble, disconnect the DSS Console from the telephone line

More information

o-o Nordson Manual (S)46.10 Series 2000 Hose/Gun Temperature Controller (S)46.10=Issued Corporation 1987 Publication No.

o-o Nordson Manual (S)46.10 Series 2000 Hose/Gun Temperature Controller (S)46.10=Issued Corporation 1987 Publication No. o-o Nordson Manual (S)46.10 Series 2000 Hose/Gun Temperature Controller (S)46.10=Issued 5/87@Nordson Corporation 1987 o-00 Data and specifications included within this mlanual are accurate at the time

More information

THE CTB08D LIGHT CONTOLLER

THE CTB08D LIGHT CONTOLLER THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller

More information

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11

Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 Protect It! 7-Outlet Surge Protector, 7-ft. Cord, 2520 Joules, Fax/Modem Protection, RJ11 MODEL NUMBER: SUPER7TEL Highlights 7 outlets / 7-ft. cord 2520 joule rating Modem/fax surge protection $75,000

More information

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series Installation Manual APEX Series Silicon and MOV Panel Protection APEX Series APEX Series Installation Guide 2 Table of Contents Mechanical Installation 3 Table One - Application Rating 3 Figure 1 - Mounting

More information

MODEL 805 USER MANUAL

MODEL 805 USER MANUAL MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Wireless General Purpose Adapter (WGA100) Installation Instructions

Wireless General Purpose Adapter (WGA100) Installation Instructions (WGA100) Installation Instructions Daintree s WGA100 DT111 forms (Rev. part 12.8.17) of the Daintree ControlScope control solution for commercial and industrial buildings. It transmits and receives messages

More information

Assembly and Operating Instructions Door Control

Assembly and Operating Instructions Door Control S10 GB Assembly and Operating Instructions Door Control Important information for: Fitters Electricians Users Please forward accordingly! These instructions must be kept for future reference. Assembly

More information

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies ADC7520 SERIES 1600W Battery Chargers and Power Supplies Wide output adjustment range 0 72VDC Analog control by external 0-5VDC voltage Temp.comp charging, sense as on option Power fail relay alarm Master-Slave

More information

EATON Transformer Module

EATON Transformer Module www.eaton.com EATON Module Quick Start Standard Features When used with standard system, EATON Module provides isolated and Step-down 0/08/0 V AC outputs. Multiple Output receptacles: 0/08/0 V AC. 86-86000-0

More information

Power Supply and Fan Module Installation

Power Supply and Fan Module Installation 3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page

More information

Series 3700 Screw Terminal Assemblies Installation Instructions

Series 3700 Screw Terminal Assemblies Installation Instructions Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Series 3700 Screw Terminal Assemblies Installation Instructions Introduction This document contains handling

More information

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral HubWayLD82CDS - UL Listed eight (8) Channel

More information

Manual Control Unit GFC 16

Manual Control Unit GFC 16 Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down

More information

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE

PEREGRINE SERIES RETROFIT INSTALLATION GUIDE 06.05.17 HanleyLED H100W-PPS524V Spec Sheet SOLUTIONS THAT MAKE SENSE PEREGRINE SERIES RETROFIT INSTALLATION GUIDE Light Up New Markets Your Local Distributor: Grimco US www.grimco.com 800.542.9941 Canada

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual 1. INTRODUCTION This family of high power remote sensing, remote control, switching mode CC\CV

More information

AirTest Model CN9000 Series Sensor Controller

AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay

More information

SEM3 - Embedded Micro Metering Module

SEM3 - Embedded Micro Metering Module SEM - Embedded Micro Metering Module Quick Reference Guide and Installation Instructions Scan QR Code for more information usa.siemens.com/sem Installation! DANGER Hazardous Voltage. Will cause death or

More information

Lighting PowerPincher Installation Instructions

Lighting PowerPincher Installation Instructions PowerPincher Installation Instructions Lighting PowerPincher Installation Instructions Description The PowerPincher is an advanced energy saving control system, designed for general office use. It combines

More information

ILC LightLEEDer MicroLite 1000P Retrofit Installation

ILC LightLEEDer MicroLite 1000P Retrofit Installation ILC LightLEEDer MicroLite 1000P Retrofit Installation Congratulations on the purchase of your new ILC LightLEEDer Retrofit System. The ILC LightLEEDer MicroLite Retrofit System is designed for the replacement

More information

Installation and Wiring

Installation and Wiring Wiring 2 2 Plan for Safety Safety Techniques WARNING: Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

Progressive Industries, Inc. EMS Electrical Management System

Progressive Industries, Inc. EMS Electrical Management System Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM

More information

AVR Series Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation

AVR Series Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation AVR Series Manual Audio / Video Power Isolation Units with Automatic Voltage Regulation Isolate. 19 Pro Series Rack Mount (RK) Faceplate Restore. Inspire! 17 Consumer Series (C) Faceplate Available in

More information

OPK SERIES PUSH-IN TYPE TERMINAL BLOCKS

OPK SERIES PUSH-IN TYPE TERMINAL BLOCKS OPK SERIES PUSH-IN TYPE TERMINAL BLOCKS Having completed the series of newly produced OPK (Push-in) spring-weighed connectors, ONKA adds up to its product range the connectors of, mm, mm, mm, 0 mm, mm,

More information

Instruction Manual HPH-8

Instruction Manual HPH-8 Specifications HPH-8 Trigger cable 120-volt, Nema 1-15 Main Power 50-amps @ 240-volt AC Power receptacles (4) Nema 5-15 or 6-15 Maximum HID wattage 8000 watts (on 240-volt) 4800 watts (on 120-volt) Maximum

More information

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL Forward The main body of text in this manual concerns four through eight channel portable chain hoist motor control systems with 208-230 VAC

More information

Mini Energy Dimmer MH-P210

Mini Energy Dimmer MH-P210 Mini Energy Dimmer MH-P210 Introduction Mini Energy Dimmer is a Z-Wave enabled module that can be set in existing in-wall switches. It supports basic command class, which can report immediate voltage,

More information

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE

BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE www.osram-americas.com/signage BoxLED DS Plus (Double Side) BX-DS-PL; BX12BA-W4F Signage Lighting System INSTALLATION GUIDE WARNING: ONLY QUALIFIED PERSONNEL SHOULD PERFORM INSTALLATION TO AVOID ELECTRICAL

More information

MPF-1, Mains Power Filter User Manual

MPF-1, Mains Power Filter User Manual 1/7 Important Safety Information 2/7 Protect the power cable from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus. Refer

More information

Instruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X

Instruction Manual. Electrical Management System (EMS) EMS-PT30X & EMS-PT50X Instruction Manual Electrical Management System (EMS) EMS-PT30X & EMS-PT50X EMS-PT50X EMS-PT30X 2 ProgressiveIndustries.net 919-267-6964 Features High/Low Voltage Protection: The EMS continuously monitors

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Modular Room Control (MRC) Series Expansion Board

Modular Room Control (MRC) Series Expansion Board Installation Instructions Issue Date December 13, 2002 Modular Room Control (MRC) Series Expansion Board Application The Modular Room Control (MRC) system has the ability to expand its input/output capabilities

More information

Sonneteer. Orton Integrated Amplifier

Sonneteer. Orton Integrated Amplifier Sonneteer Orton Integrated Amplifier Introduction Thank you for purchasing the new Sonneteer Orton integrated amplifier. For your safety and proper operation of your amplifier, please take time to read

More information

120VAC Interface Option Cards for V7/ V74X / GPD315 Drives

120VAC Interface Option Cards for V7/ V74X / GPD315 Drives YASKAWA 120VAC Interface Option Cards for V7/ V74X / GPD315 Drives INSTRUCTIONS Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Catalog Number Identification with Elements Explained V V V V X 347 V Hz Owner s Manual 917 & 918 Remote Control Switches TABLE OF CONTENTS page Ratings & Installation... 1 2 Optional Accessories... 3 4 Troubleshooting & Parts Kits... 5 Wiring & Outline Diagrams... back of

More information

AD-7830 Servo Amplifier

AD-7830 Servo Amplifier Instruction Manual IM-0606 AD-7830 Servo Amplifier Table of Contents General Information... 2 Introduction... 2 Receiving/Inspection... 2 Storage... 2 Equipment Return... 2 Abbreviations Used in This Manual...

More information

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation. Product No. 99-600-91 Rev. B Page 1 of 8 MCG Surge Protection Model 160MXT Installation Instructions Important Warranty Information MCG surge protectors are designed to work at specific voltages and configurations,

More information

ASI Systems ML5720A Series

ASI Systems ML5720A Series ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

Panel Installation Datasheet

Panel Installation Datasheet ACTIONPAC LNS5 & SAFEGARD V5 Panel Installation Datasheet ELECTROSTATIC SENSITIVE DEVICE This product forms part of a life safety system. Failure to correctly store, handle, install and maintain the product

More information

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper

Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper Installation/Operating Instructions 220V VCB Silhouette/Series E Electric Video Conferencing Background by Draper Caution 1 Read instructions through completely before proceeding; keep them for future

More information

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0 170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become

More information

Quick Start Guide. C-100 Series Switches

Quick Start Guide. C-100 Series Switches Quick Start Guide C-100 Series Switches C-100 SERIES QUICK START GUIDE Warnings and Cautionary Messages!! Warning: This product does not contain any serviceable user parts. Warning: Installation and removal

More information

Transceiver Hub with Integral Camera Power

Transceiver Hub with Integral Camera Power Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub

More information

CH 2 CH 1 BALANCED INPUTS

CH 2 CH 1 BALANCED INPUTS P.I.P.- FTE + + + = NON-INVERTING = INVERTING CH 2 CH 1 BALANCED INPUTS CAUTION DO NOT USE AMPLIFIER PHONE JACKS WITH THIS MODULE PLUGGED IN. 1997 by Crown International, Inc., P.O. Box 1000, Elkhart,

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

Wireless Fixture Adapter (WFA100-SN) Installation Instructions

Wireless Fixture Adapter (WFA100-SN) Installation Instructions Installation Instructions The Daintree Wireless Fiture Adapter () forms part of Daintree s Controlscope Manager (CSM) in commercial and industrial buildings. It transmits and receives messages over the

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Family Modification Watts Dimmable CCT ASD-UHB 2 XX D XX LED UFO High Bay 100 = 100 W Dimmable 50 = 5,000 K 150 = 150 W 200 = 200 W

Family Modification Watts Dimmable CCT ASD-UHB 2 XX D XX LED UFO High Bay 100 = 100 W Dimmable 50 = 5,000 K 150 = 150 W 200 = 200 W Our New UFO style round high bay is the latest in LED technology. Smaller, more efficient, and longer lasting, our new IP WET location rated LED UFO high bay fixture is at 1lm/w achieving desired light

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015 Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015 Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions

More information

UPS READY POWER DISTRIBUTION ASSEMBLY

UPS READY POWER DISTRIBUTION ASSEMBLY UPS READY POWER DISTRIBUTION ASSEMBLY FOR TRAFFIC CABINETS with LED Signals INSTALLATION & OPERATOR S MANUAL VERSION 1.2 1 Note The instructions contained in this manual are not intended to cover all of

More information

LED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT:

LED Gooseneck light FEATURES AND BENEFITS: ORDERING MATRIX: LED GOOSENECK LIGHT: ASD LED Gooseneck Barn Lights couple rustic style with modern LED technology. This timeless classic was frequently used on barns, warehouses, and industrial complexes during the early 2th century and is

More information