TECHNICAL SPECIFICATIONS. technical and electrical characteristics. applicable standardisation documentation
|
|
- Felicia Bridges
- 5 years ago
- Views:
Transcription
1 a o m t TECHNICAL SPECIFICATIONS technical and electrical characteristics applicable standardisation documentation
2 TECHNICAL SPECIFICATIONS Referência do Repartidor / Derivador 5167 Nº Saídas Banda Freq. Aten. ATI 4 5 MHz (db) 8 60 MHz (db) 8 90 MHz (db) 8 s de inserção 750 MHz (db) MHz (db) MHz (db) MHz (db) 10 entre saídas (db) DC saídas-entradas tipo
3 ADAPTORS DCP (POWER CONTROL DEVICE) MODULAR EQUIPMENT IP PROTECTION FUNCTIONALITY SIZE READING Door Frame An elevated index of functionality with easy separation and adaptation of the casing components. W Polyurethane Joint Polyurethane Joint Enclosure / Base H D W x H x D (Width x Height x Depth) CONCEPT: FM / SM FM SM SM with without without frame frame frame QUALITY ASSURANCE The marking in relief of the logotype guarantees genuine products. With the CE (EC) mark, also in raised lettering, a commitment is made to guarantee the fulfilment of the standards documents and the Low-Voltage Directive. Flush Mounted Semi-surface Mounted Surface Mounted 66
4 SAFETYMAX STANDARDISATION (LEGAL) DOCUMENTATION TECHNICAL REGULATIONS FOR LOW-VOLTAGE ELECTRICAL INSTALLATIONS - Order 949-A/2006 of September 11th. DIRECTIVE OF LOW-VOLTAGE 2006/95/CE - Law-Decree 6/2008 of January 11th. EN62208 Empty casings for low-voltage equipment sets General regulations. EN Sets of low-voltage equipment. Part 1: General requirements. EN Enclosures and casings for electrical equipment for fixed electrical installations for domestic use and the like. Part 22: Specific regulations for terminal boxes and casings. residence in areas where non-qualified individuals pass, with a flush mounted (FM) or surface mounted (SM). They should be mounted on non-flammable walls. The enclosures for the meter and provider network connection have the necessary conditions to also be installed in the exterior of the building. The SAFETYMAX series offers a wide range of products. The enclosures (bodkins) can easily be grouped, providing various solutions for diverse applications. ENCLOSURES FOR METER track to be mounted on the single or triple phase meter. (Low-Voltage) (Up to 41.4KVA 60 A in triple phase). SPECIFICATIONS OF THE ENERGY DISTRIBUTOR DIT-C14-100/N Connection of LV Clients Standardised Technical Solutions DMA-C62-807/N Materials for derivations and LV inputs Low-Voltage Enclosure for Provider Network Connection Characteristics and trials. DMA-C62-810/N Switch box for subterranean grids Characteristics and Trials DMA-C62-815/N - Materials for derivations and LV inputs Consumption/Production Enclosure 100A/25A - Characteristics and trials DMA-C Materials for derivations and LV inputs Meter enclosures for current transformers for reading points of SLV clients Technical Characteristics Standardised class II insulation enclosure for the installation of Low-Voltage electrical equipment, with a base box in polystyrene and the Frame/door in white lacquered aluminium. ENCLOSURES FOR DISTRIBUTION BOARD AND POWER CONTROL+DISTRIBUTION BOARD installation of the equipment. types of DCP s (Power Control Devices). Power control device Apparatus intended to stop the contracted power from being surpassed. equipment. with the casing according to the number of modules to be fixed to the brackets located on the bottom of the casing in the upper and lower regions. Identification tags are supplied with the product. casings for a surface mounted application (EXT) on larger switchboards. Technical Characteristics Insulation voltage of Ui 690V The equipment to be installed in the interior of the enclosures should not have a thermal dissipation power of over 75W. The enclosures with Reinforcement of the Mechanical Resistance (RRM) are class II insulation, comprised of an interior enclosure in plastic with an exterior reinforcement and a steel plate door. The enclosures are preferably to be used in the interior of the 67
5 SAFETYMAX P100A ENCLOSURE 2E+2S SWITCH BOX The P100A enclosures are intended to be flush mounted on the wall and for installation on the exterior of a building, in areas where non-qualified individuals pass. A cylindrical style lock with a round frame should be installed, in accordance with DMA-E84-002/N. However, a triangular plastic lock is supplied (Ref ). The P100A enclosure is equipped with three 22x58 single pole fuse bases for the connection of the exterior phase conductors and isolating neutral base, for the connection of unprepared conductors. The product is qualified by EDP (energy supply company) in accordance with DMA C /N The 2E+2S Switch Box is equipped with six NH00 fuse bases which allow the derivation of two protected channels (branches) stemming from one main channel. The neutral bar is mounted to the left, with the option of being mounted to the right. It includes a triangular plastic lock (Ref ). We recommend that the energy distributor be contacted before installation. PC/P ENCLOSURE P400A ENCLOSURE The P400A enclosures are intended to be flush mounted on the wall and for installation on the exterior of a building, in areas where non-qualified individuals pass. The P400A enclosure has a retractable-like lock, in accordance with DMA-E84-006/N, which allows the door to be closed on the bottom, in the centre and on top. It is equipped with three NH2 single pole fuse bases and an isolating neutral base. The product is qualified by EDP (energy supply company) in accordance with DMA C /N The consumption/production enclosure is equipped with a 22x58 3P fuse base to protect the installation circuit use and 10x38 P+N fuse base to protect the microproduction circuit. The circuit plate is mounted with two terminals. It includes a triangular plastic lock (Ref ). PC/P enclosure is intended to be installed in solutions A,B,E, according to the technical specifications defined at
6 SAFETYMAX ENCLOSURE FOR PROVIDER NETWORK CONNECTION ELECTRICAL CHARACTERISTICS Operating voltage: Ue 230v/400v ~ Ground system type: TT Maximum Voltage: 400V (between phases) Forms of internal separation: Form 1 Insulation Voltage: Ui 500V Impulse Voltage: Uimp 6kV Short circuit current: ICC 10kA Level of pollution: 3 Connection type: FF- Environment: CEM - B Frequency: 50Hz Degree of protection:ip55 Protection measures against electrical shocks: class II closed casing 69
7 SAFETYMAX (TI S) Enclosure to accommodate the current transformer at the measuring point for SLV clients (> 41.4KVA). Equipped with a 30x10 copper bar to incorporate the current transformers up to 300/5A (in the case of 3 phases, it shall be the primary for the current transformer). Manufactured in accordance with DMA-C on the levels corresponding to the electrical installations (of use) served by the outputs derived from them. They should have a cover with a locking device which will guarantee its inviolability. (Source: RTIEBT Section ) The rising main switchboard enclosure should be easily accessible to energy distribution personnel and should be installed, as a rule, between 2m and 2.8m above the pavement. (Source: RTIEBT Section ) Enclosure for installation in the rising main switchboard for derivation to the electrical installations in use, prepared for three phase inputs and for the installation of 22x58, 14x51 NH bases (1,2,3,4 Outputs) disconnectors. Product available with a depth of 125 and 200mm. The rising main switchboard enclosures should be installed ELECTRICAL CHARACTERISTICS OF RISING MAIN SWITCHBOARD ENCLOSURES AND CURRENT TRANSFORMER ENCLOSURES Operating voltage: Ue 230v/400v Ground system type: TT Maximum Voltage: 400V (between phases) Forms of internal separation: Form 1 Insulation Voltage: Ui 500v Impulse Voltage: Uimp 6kV Connection type: FF- Environment: CEM - B Short circuit current: ICC 10kA Level of pollution: 3 Frequency: 50 Hz Degree of protection:ip54 Protection measures against electrical shocks: class II closed casing Current Transformer: 250A and 400A 70
8 SAFETYMAX APPLICABLE STANDARDS DOCUMENTS EN :2006 Enclosures and casings for electrical equipment for fixed electrical installations for domestic use and the like. Part 22: Specific regulations for terminal boxes and casings. Order 949-A/2006 of September 11th - Technical Regulations For Low-Voltage Electrical Installations (RTIEBT) TECHNICAL CHARACTERISTICS OF THE CASING The Main Ground Terminal (TPT) Enclosure connects the Ground Electrode with ground installation of the building. The TPT enclosure has a movable connector which allows for the measurement of the resistance value of the ground electrode, according to what is defined in part of the RTIEBT. The movable connector can only be disassembled with the use of a tool. It is mechanically secured (safety screw) to ensure the electrical continuity of the ground connections. Possesses a triangular plastic lock. CONNECTION CAPACITY (GROUND BOX R-0491) Ref Ground measurement box with 1 input and 5 outputs - 1 Input (1 Conductor) 1x25mm2-5 Outputs (5 Conductors) - 1x25mm2 and 4x16mm2 Ref Ground measurement box with 1 input and 1 output - 1 Input (1 Conductor) 1x25mm2-1 Output (1 Conductor) - 1x25mm2 Ref Ground measurement box with 5 inputs and 5 outputs - 5 Inputs (5 Conductors) 1x25mm2 and 4x16mm2-5 Outputs (5 Conductors) - 1x25mm2 and 4x16mm2 The ground measurement boxes R0491 are intended for the connection of unprepared conductors. CONNECTION CAPACITY (TPT) / INPUT 25x6 Constituted bar with 3 inputs for the connection of the prepared cable. 1 Input (M8) 16 to 70mm2 2 Inputs (M10) 16-95mm2 OUTPUT 25x6 Constituted bar with 5 outputs for the connection of the prepared cable. 5 Outputs (M8) 16-70mm2 MOVABLE CONNECTOR 25X6 bar, disassembled with a tool and safety screw Safety Screw / INPUT 30x10 Constituted bar with 3 inputs for the connection of the prepared cable. 1 Input (M8) 16 to 70mm2 2 Inputs (M10) 16-95mm2 OUTPUT 30x10 Constituted bar with 8 outputs for the connection of the prepared cable. 8 Outputs (M8) 16-70mm2 MOVABLE CONNECTOR 30X10 bar, disassembled with a tool and safety screw Safety Screw 71
9 RAQUITED 1ST EDITION 2ND EDITION ITED (Telecommunication Infra-structures in Buildings) Manual (2nd Edition) of November 2009 Requirements and Technical Specifications of Telecommunication Infrastructures in Buildings. Law-Decree 123/2009, of May 21st, altered by Law-Decree 258/2009 of September 25th ITED Legal Document Directive of Low-Voltage 2006/95/CE (Law-Decree 6/2008 of January 10th) RAQUITED is comprised of a white box, similar to a frame, to incorporate the 19 panels with the passive equipment (RC-PC, RC-CC and RC-FO). It is prepared for ventilation by natural convection with the possibility of forced ventilation. With RAQUITED it is possible to invert the opening of the door. The lateral panels, with an opening system, allow for easy access into the interior of the frame. The 19 panels for the frame are supplied with the passive equipment for the copper pair (PC), Coaxial (CC) and Optic Fibre (FO). All panels include a mounting set ( CONJ RAQUITED PARAF PORCA). The RAQUITED 19 panels, to derivate or distribute the signal in the Copper Pair, are CAT6 and allow for the connection of the cable screen (shield) to the ground. The Panels for the Optic Fibre are supplied with 4 double SC/APC adaptors. It allows for a good management of the cables, pre-cut at the top, base and back area. RAQUITED COAXIAL DISTRIBUTION FRAME CHARACTERISTICS DISTRIBUTION FRAME / DIVERTER CC OUTPUTS MHz MHz MHz ATTENUATION (db) 750 MHz MHz MHz MHz MHz REJECTION BETWEEN OUTPUTS >20 MAXIMUM CURRENT 1A 72
10 RISING MAIN SWITCHBOARD RISING MAIN SWITCHBOARD TECHNICAL REGULATIONS FOR LOW-VOLTAGE ELECTRICAL INSTALLATIONS - Order 949-A/2006 of September 11th. DIRECTIVE OF LOW-VOLTAGE 2006/95/CE - Law-Decree 6/2008 of January 11th. EN Sets of low-voltage equipment. Part 1: General requirements. EN Sets of low-voltage equipment. Part 2: Sets of power equipment. EN Sets of Low-Voltage Equipment - Part 3 Specific rules for sets of low-voltage equipment which can be used by non-qualified individuals Switchboards. TECHNICAL CHARACTERISTICS The enclosures for the rising main switchboards are metallic; however after being electrified they have an insulation equivalent to class II, guaranteeing that: The bare active components (for example, such as the non-insulated derivation slide bars and connection terminals) are separated from all conductor parts by a distance of no less than 20mm; Transparent polycarbonate cover in the derivation slide bar enclosure and output protection. The rising main switchboard is comprised of: Main Shut-off Switch Box Should be a simultaneous shutting off of all active conductors. between the shut-off switch box and the output protection box; 22x58 or 14x51 disconnectors. ELECTRICAL CHARACTERISTICS EQUIPPED CLASS II RISING MAIN SWITCHBOARD Operating voltage: Ue 230v/400v ~ Ground system type: TT Maximum Voltage: 400v (between phases) Forms of internal separation: Form 1 Insulation Voltage: Ui 500v Connection type: FF Impulse Voltage: Uimp 6Kv Environment: CEM1 Short circuit current: ICC 10 KA Level of pollution: 3 Frequency: 50 Hz Degree of protection:ip43 IK07 The minimum protection indexes for the rising main switchboard, specified in the Technical Regulations section 321 External Influences Code, corresponds to codes AD2, AE3 and AG2 and are equivalent to IP41 IK07. The protection indexes of equipped switchboards manufactured by Quitérios are superior to the minimum values required in the RTIEBT. In the rising main switchboards, protection is IP43-IK07 and corresponds to codes AD3, AE3 and AG2. 73
11 RISING MAIN SWITCHBOARD RISING MAIN SWITCHBOARD MINIMUM SECTIONS OF PROTECTION CONDUCTORS Conductor Section of S F phase (mm 2 ) S 16 SPECIFICATIONS FOR THE SEPARATED CONDUCTORS (PHASES) EN Minimum protection conductor section (PE, PEN) S P (mm 2 ) 16 < S < S 400 S / < S < S S / 4 Normal Current A S Flexible Conductors (mm2) 15 1,5 21 2, RELEVANT INFORMATION IN THE TECHNICAL REGULATIONS (RTIEBT) Collective Installation (803) Electrical installation established, as a rule, in the interior of a building, with the objective of serving as the electrical installation (for use) explored by different entities, constitutes a common part (of the collective installation), rising main switchboard, switchboard and switchboard enclosure. Equipment used ( ) The equipment used in the collective installations and inputs directly connected to distribution grids in connection diagrams to ground TT should be class II insulation or an equivalent insulation. Rising Main Switchboard (803.3) Every building, as a rule, should have one rising main switchboard. The rising main switchboard should be located in the interior of the building, and in as much as possible, near its normal access and the respective hatch or hatches, when they exist. The rising main switchboard should be installed in an appropriate location with easy access and so that the mounted components are in a position that are easily accessible from the floor. The location and the installation of the rising main switchboard should be in a place that if an accident should occur in its interior, it would not hinder, under any circumstances, an evacuation of people or the organisation of first aid. 74
12 METER ASSEMBLIES METER ASSEMBLIES EN Sets of low-voltage equipment. Part 2: Sets of power equipment. Order 949-A/2006 of September 11th Technical Regulations for Low-Voltage Electrical Installations (RTIEBT) EDP Documents DIT-C14-140/N Regulations for the design of distribution boards or panel meters Meter Assemblies in Buildings. Insulation class II standardised enclosures to incorporate protection and meter equipment for Low-Voltage. The casings are comprised of: Base enclosures made of hot pressed polyester and reinforced with fibreglass, Transparent polycarbonate cover. The meter assemblies are sized (with space) for three phase inputs and for three phase meter equipment, even if the installation has been designed for a single phase, so that it allows for a future passing of single phase to three phase input. The covers are affixed with screws with the possibility of sealing. The derivation slide bar enclosure can hold the terminal and the fuses, or separate enclosures can be used for the terminal and for the fuses. The meter assemblies gives priority to the electrical design; if indicated 14x51 disconnectors can be installed, although the DIT-C14-140/N does not recommend their installation. The meter assemblies are comprised of a set of equipment (disconnectors, cables and connectors) for each meter equipment unit to be installed. The equipment sets are comprised of: 14x51 disconnectors (three pole or single pole), 10mm2 rigid cable and connection terminals (4 poles or 2 poles). 22x58 disconnectors (three pole or single pole), 16mm2 rigid cable and connection terminals (4 poles or 2 poles). SHOCKS The Meter Assemblies set is Class II insulation, with an IP44 and IK09 protection index. Access is obtained through the use of a tool or key. The transparent cover allows for an easy reading and control of the meter equipment and other elements. ELECTRICAL CHARACTERISTICS Operating voltage: Ue 230v/400v ~ Ground system type: TT Maximum Voltage: 400v (between phases) Forms of internal separation Form 3b Form 1 Insulation Voltage: Ui 500v Connection type: FF- Impulse Voltage: Uimp 6Kv Environment: CEM B Short circuit current: ICC 10KA Level of pollution: 3 Frequency: 50 Hz Climate Class: A (105ºC) Auto extinguishing: 960ºC Diversity factor: 0.7 COMPARATIVE TABLE OF RISING MAIN SWITCHBOARD VS METER CENTRALISATION UNIT Solution Type of Casing Type of Closure Type of Insulation Protection Indexes Output Protection Additional Solutions Rising Main Switchboard Meter Assemblies Metallic Plastic triangular lock Equivalent to class II IK 07/ IP43 Pressed polyester and reinforced with glass fibre Plastic triangular screws Class II Insulation IK 09/ IP44 NH Bases 14x51 / 22x58 Disconnectors 14x51 / 22x58 Disconnectors Grouping of common service distribution boards of 16 or 64 modules Option of opaque covers, with the exception of meter boxes 75
13 METALLIC SERIES METALLIC SERIES STANDARDISATION (LEGAL) DOCUMENTATION TECHNICAL RULES FOR LOW-VOLTAGE ELECTRICAL INSTALLATIONS Order 949-A/2006 of September 11th Directive of Low-Voltage 2006/95/CE - Law-Decree 6/2008 of January 11th EN Empty casings for low-voltage equipment sets General rules. EC Declaration of Conformity sustained by the Technical Dossier of Standardisation Technical documentation on the design, manufacture and function of the product according to the Directive of Low-Voltage 2006/95/CE. Available for download at The following are indicated on the product s characteristics plate: brand, model, designation, lot, protection indexes, IP and IK, and applicable standards documents (DNA). In the Switchboard Enclosure, the Switchboard and the DCP (Power Control Device), the chassis system is movable with DIN rails for the direct installation of the equipment and individual covers per groove. POWER CONTROL DEVICE Apparatus intended to stop the contracted power from being surpassed. The functionality of the product allows it to be easily adapted to diverse brands of electrical equipment. The Ground and Neutral derivation slide bars are supplied with the casing according to the number of modules to be fixed to the brackets located on the bottom of the enclosure. Class I insulation metallic enclosures for the installation of electrical equipment for Low-Voltage. The enclosures are preferably to be used in the interior of the residence in areas where non-qualified individuals pass, with a flush mounted (FM) or surface mounted (SM), with IP54 and IK07. The enclosure base and door are manufactured in zinc plates with an aluminium frame and are white lacquered. Continuity of the ground circuit protector is ensured by the metallic screws fixing the frame to the enclosure base and through the connector between the frame and the door. 76
14 DEGREE OF PROTECTION DEGREE OF PROTECTION IP (NP EN 60529) and IK (EN 62262) Protection indexes specified in the Technical Regulations section 321 External Influences Code CHARACTERISTICS OF THE EQUIPMENT IN THE PRESENCE OF WATER TO WHICH IT MIGHT BE SUBJECTED PRESENCE OF WATER Code Classification Characteristics Condition to be observed AD1 Negligible Places where the presence of water is negligible. IPX0 AD2 Drops of water Places where it may be subject to the vertical fall of water droplets. IPX1 AD3 Rain Places where it may be subject to rainfall falling in a direction creating a vertical angle of no more than 60º. AD4 Sprays of water Places where it may be subject to sprays of water from all directions. IPX4 AD5 Streams of water Places where it may be subject streams of water from all directions. IPX5 AD6 Strong streams of water or large amounts of water Places where it may be subject to waves (of water). AD7 Temporary immersion Places which may be partially or totally covered with water. IPX7 AD8 Prolonged immersion Places which may be totally covered with water in a permanent manner. IPX8 IPX3 IPX6 CHARACTERISTICS OF THE EQUIPMENT IN THE PRESENCE OF FOREIGN SOLID MATTER TO WHICH IT MIGHT BE SUBJECTED PRESENCE OF FOREIGN SOLID MATTER Code Classification Characteristics Condition to be observed AE1 Negligible Absence of noticeable dust or foreign solid matter. IP0X AE2 Small objects Presence of foreign solid matter whose smallest size is no less than 2.5mm. IP3X AE3 Very small objects Presence of foreign solid matter whose smallest size is no less than 1.0mm. IP4X AE4 Light dust Presence of dust deposits in daily quantities of (q): 10<q 35 mg/m2. a) AE5 Average dust Presence of dust deposits in daily quantities of (q): 35<q 350 mg/m2. IP5X or IP6X AE6 Abundant dust Presence of dust deposits in daily quantities of (q): 350<q 1000 mg/m2. a) a) without correspondence in the RTIEBT (Technical Regulations for Low-Voltage Electrical Installations). CHARACTERISTICS OF THE EQUIPMENT CORRESPONDENT TO IMPACTS TO WHICH IT MIGHT BE SUBJECTED MECHANICAL ACTIONS PROTECTION AGAINST IMPACTS Code Classification Characteristics Condition to be observed AG1 Weak Places of residence and the like. IK02 AG2 Average Current industrial facilities. IK07 AG3 Strong Industrial facilities subject to severe conditions. IK08 through IK10 77
TECHNICAL SPECIFICATIONS SAFETYMAX
APPLICABLE REGULATORY AND STANDARDISATION (LEGAL) DOCUMENTATION TECHNICAL REGULATIONS FOR LOW-VOLTAGE ELECTRICAL INSTALLATIONS - Order 949-A/2006 of September 11th. DIRECTIVE OF LOW-VOLTAGE 2006/95/CE
More informationTELECOMMUNICATION SOLUTIONS
42 44 47 47 50 52 VDI_RACK - STANDARD SOLUTION VDI_RACK - MODULAR CONSTRUCTION ACCESSORIES FIBER OPTIC PATCH CORDS SIGNAL SPLITTERS (PC/ CC/ FO) FOR TELECOM CABINETS S ENCLOSURES AND CABINETS Free online
More informationTELECOMMUNICATION SOLUTIONS
42 44 47 47 50 52 VDI_RACK - STANDARD SOLUTION VDI_RACK - MODULAR CONSTRUCTION ACCESSORIES FIBER OPTIC PATCH CORDS SIGNAL SPLITTERS (PC/ CC/ FO) FOR TELECOM CABINETS TELECOMMUNICATIONS ENCLOSURES AND CABINETS
More informationDX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationCABINETS & ENCLOSURES FOR PREPAYMENT METERS
CABINETS & ENCLOSURES FOR PREPAYMENT METERS Solutions designed according to customer need, conceived for every type of prepayment meter: > Meters with keypad data entry terminal > Split meters with remote
More informationProduct Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11
Technical Information Product Details Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11 Contents The Sunny String Monitor SSM24 11 is specifically designed for monitoring large PV generators.
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationmodular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security
aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,
More informationK1K015NZ4 cam stepping switch - 2-pole A - screw mounting
Characteristics cam stepping switch - 2-pole - 60-12 A - screw mounting Complementary Number of steps 5 Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationict contactors EN 61095, IEC 1095 Interference
ict contactors DB23399 DB669 DB06604 Country approval pictograms EN 6095, IEC 095 ict contactors are available in two versions: b Contactors without manually-operated b Contactors with manually-operated.
More informationADJUSTABLE FLOOR BOXES
ADJUSTABLE FLOOR BOXES TABLE OF CONTENTS Description Applications References Configuration type Installation Technical Data Mechanism compatibility Dimensions Description Floor housings for electrical
More informationThe right solution for every home
Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationLXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual
LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka
DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More information5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009
Siemens AG 9 BETA Protecting SR Busbar Systems /2 Product overview /3 Distribution board components /9 Built-in components /17 Mounting components Siemens ET B1 10/9 BETA Protecting SR Busbar Systems Siemens
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationXL 4000 metal free-standing enclosures and cable compartments
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax : 05 55 06 88 88 XL metal free-standing enclosures and CONTENTS PAGE 1. General characteristics...1 2. Range...2 3. Overall dimensions...2 4. Equipment...3
More informationIndicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green
22.5 mm 3.5 mm IP65 1 A 66 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales office. INDICATOR
More informationK1F003MCH cam ammeter switch - 3 circuits A - for Ø 22 mm
Product data sheet Characteristics cam ammeter switch - 3 circuits - 90-12 A - for Ø 22 mm Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationConsumer units IP66 >> M135 DOMINO IP66 Series [enclosure] 672.
1 Empty enclosures DOMINO IP66 Series Consumer units IP66 >> M135 INDUSTRY 2 DIN 2 3 4 CONSUMER UNIT Modularity No. Modules Dimension Power IP66 M135 2 MOD. 135x76x102mm 6W 2002 1/24 DOMINO IP66 Series
More informationSDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)
SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension
More informationArgenta W A L L M O U N T I N G M E T A L C A B I N E T S
Argenta W A L L M O U N T I N G M E T A L C A B I N E T S The ARGENTA Series is a group of metal enclosures used to house on the inside electrical or electronic switchgear, controlgear and equipment necessary
More informationPRO-1250D CT MID DIN rail three phase four wire energy meter.
PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions
More informationK1F006ALH cam switch - 6-pole A - screw mounting
Characteristics cam switch - 6-pole - 45-12 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting
More informationApplications
Han PCB adapter Contents Page Technical characteristics PCB adapter for Han DD... 20.02 Han DD Inserts with PCB adapter... 20.03 Technical characteristics PCB adapter for Han E... 20.04 Han E Inserts with
More informationLOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E
LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11
More informationPan assemblies and installation accessories
Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationPRO1 V21.xxx series MID DIN rail single phase two wire energy meter
PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1D V21.212 Version 1.1 Note: the picture on the frontpage is a meter from the series of this meter, it might not be exactly the same
More informationSivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip
Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability
More informationDatasheet - AZ 15 ZVRK
24.12.2015-09:51:40h Datasheet - AZ 15 ZVRK Safety switch with separate actuator / AZ 15 Preferred typ Thermoplastic enclosure Double-insulated Long life 52 mm x 75 mm x 30 mm Multiple coding Large wiring
More informationSR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories
/ SR0 Busbar System General Data / Busbar routing / Mounting components / Accessories / SR0 Busbar System General Data Overview The SR0 busbar system is a modular system for busbars, for installation in
More informationthe Santon FCS-type switch Disconnect Superior Switch Solutions
the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal
More informationDatasheet - ZR Z
Print - Create PDF - Create EXCEL file 21.04.2011-16:57:42h Datasheet - ZR 236-11Z Position switch / 236 thermoplastic enclosure - DIN EN 50047 with Actuator / 236 Roller plunger R thermoplastic enclosure
More informationDatasheet - SRB 402EM-24V
Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor
More informationSystem solutions for your energy requirements
System solutions for your energy requirements Power distribution from the smallest to the largest The tried-and-tested, highly fl exible power distribution system for individual requirements. From small
More informationIP degrees of protection. Degrees of mechanical shock protection IK conforming to the CEI EN Standard
Definition of IP degree of protection, IK degree of mechanical shock protection and self-extinguishing degree of protection IP degrees of protection 1 st DIGIT: PROTECTION AGAINST SOLID BODIES 2 nd DIGIT:
More informationDRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria
DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions
More informationXTM1250SA DIN rail three phase four wire LCD display energy meter
XTM1250SA DIN rail three phase four wire LCD display energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Intrinsic errors 1.6 Description 1.7 Dimensions 1.8
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationPRO-75 SERIES. User manual
PRO-75 SERIES DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationWIDE RANGE OF SOLUTIONS
network solutions WIDE RANGE OF SOLUTIONS 19 wall mounted racks with 6, 8, 13 and 17U and floor mounted with 24U 10 wall mounted Racks 6U Available in white (RAL 9010), grey (RAL 703) and black (RAL 900)
More informationPRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5
PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8
More informationIT infrastructure Efficiency-boosting solutions. nextlevel. for data centre
IT infrastructure Efficiency-boosting solutions nextlevel for data centre 2 Rittal IT infrastructure The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind,
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationHan-Brid. Contents Han-Brid Features Han-Brid Data interfaces Han-Brid Overview Han-Brid Cu
Contents Page Features... 19.02 Data interfaces... 19.03 Overview... 19.04 Cu... 19.06 F.O.... 19.08 Quintax 3 A... 19.10 RJ45 C... 19.12 USB / FireWire... 19.14 Han 4 A SC... 19.16 Hoods/Housings... 19.18
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationKaedra system PB102271
PB102271 Index General presentation 72 Selection guide 75 Enclosures for sockets 76 Enclosures with interface 77 Enclosures for modular devices 78 Universal enclosures 79 The functional plates 80 Accessories
More information1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings
Siemens AG 200 ALPHA SIMBOX Small Distribution Boards /2 Introduction /2 Introduction /3 Flush-mounting and hollow-wall distribution boards /4 Hood-type distribution boards /5 Accessories /6 Dimensional
More informationHan PCB termination. Han-Fast Lock PCB adapter for Han DD PCB adapter for Han DDD module
Han termination Contents Page Han-Fast Lock... 20.11 adapter for Han DD... 20.13 adapter for Han DDD module... 20.16 adapter for Han 40 A Axial module... 20.18 adapter for Han E... 20.20 adapter for Han
More informationCENTERLINE 2500 Motor Control Centers
CENTERLINE 2500 Motor Control Centers High Performance Motor Control Centers and Switch Gear Meeting IEC 61439-2 Product Description Allen-Bradley CENTERLINE 2500 motor control centers (MCCs) are designed
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationModular surge protective devices (SPDs) Cat. Nos :
Contents Page 1. General characteristics...2 2. Overall dimensions...4 3. Technical characteristics...4 4. Conformity...9 5. Mounting...9 6. Accessories.............................11 Product information
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More informationDatasheet - AZ 16-02ZVK
Print - Create PDF - Create EXCEL file - Hide system components 03.10.2011-10:28:14h Datasheet - AZ 16-02ZVK Safety switch with separate actuator / AZ 16 Image Preferred typ 3 cable entries M 16 x 1.5
More informationCMSA-100 Manual. Cinema Media Server Automation
CMSA-100 Manual Cinema Media Server Automation 181 Bonetti Drive San Luis Obispo, CA 93401-7397 USA Phone: +1 805 549 0161 Fax: +1 805 549 0163 www.uslinc.com Table of Contents 1. Safety Notice... 3 2.
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationRiLine Compact The smart power distribution system
RiLine Compact The smart power distribution system 2 Power distribution in a confined space Rittal are the leading suppliers of reliable power distribution and backup systems for controlgear. The new RiLine
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationDatasheet - AZ 15 ZVRK
22.02.2016-18:22:40h Datasheet - AZ 15 ZVRK Safety switch with separate actuator / AZ 15 Preferred typ Thermoplastic enclosure Double-insulated Long life 52 mm x 75 mm x 30 mm Multiple coding Large wiring
More informationFeatures: S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras
S98-B v1.0 S98-B 9-port switch with buffer power supply for 8 IP cameras Edition: 3 from 15.11.2017 Supercedes the edition: 2 from 09.01.2017 EN** Features: Uninterruptible power supply of 8 IP cameras
More informationZener Barriers Bulletin 937Z
Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution
More informationDatasheet - ZS Z
Datasheet - ZS 236-11Z Position switch / 236 thermoplastic enclosure - DIN EN 50047 with Actuator / 236 Plunger S thermoplastic enclosure Good resistance to oil and petroleum spirit Wide range of alternative
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationTongue Switches Trojan 5 & 6
Interlock Switches Description The Trojan family is a universal tongue (or key) actuated safety interlock switch designed to fit at the leading edge of sliding, hinged or lift-off guards. The dual key
More informationOrdering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R
13.06.2016 05:27:33h Datasheet AZM 161SK 12/12RI 024 B6R Solenoid interlock / AZM 161I / AZM 161I B6R right hand model Compact design Interlock with protection against incorrect locking. For very smal
More informationSafety switches with separate actuator
4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC
More informationDatasheet - RSS 36-D-R-ST
14.03.2018-19:30:37h Datasheet - RSS 36-D-R-ST Safety sensors / RSS 36 Thermoplastic enclosure RFID-technology for needs-based protection against tampering Misaligned actuation possible 27 mm x 108.2 mm
More informationApplication Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60
DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationDesk Grommet Number(s) : to 52, to 58, to 63,
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Desk Grommet Number(s) : 0 540 50 to 52, 0 540 55 to 58, 0 540 60 to 63, CONTENTS PAGES 1.Range 1 to 3 2.Installation 4 to 9 3.Technical
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationAdaptors Busplug Low Voltage Switchboard Equipment
Busplug Adaptors Low Voltage Switchboard Equipment Publication BA 2012 CONTENTS Descriptive Advantages of Busplugs 2 General Description 3 Use of Busplugs Adaptors 3 Construction 4 Technical Standards
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationDatasheet - AZ 16-03ZVRK
23.07.2015-02:06:20h Datasheet - AZ 16-03ZVRK Safety switch with separate actuator / AZ 16 Preferred typ Thermoplastic enclosure Double-insulated Large wiring compartment 52 mm x 90 mm x 30 mm Multiple
More informationVERAK IP. 19 Stand Alone Cabinet with IP65 Rating.
19 Stand Alone Cabinet with IP65 Rating www.apw.eu.com Overview Material specification Frame: Steel 2.0 mm Panel mounting angles and reducing channels: Steel 2.0 mm Panel mount supports: Steel 1.5 mm Side
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationPHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.
Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.
More informationK1D011B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 30-12 A - for Ø 22 mm Complementary Main Number of decimal 11 Switching angle 30 Range of product Product or component type Component name
More informationDatasheet - AZM300Z-ST-1P2P-A
08.04.2015-16:04:56h Datasheet - AZM300Z-ST-1P2P-A Solenoid interlock / AZM300 Suitable for mounting to profile systems Thermoplastic enclosure 3 different directions of actuation Compact design 3 LEDs
More informationDatasheet - AZ 15 ZVRK
01.08.2013-16:47:56h Datasheet - AZ 15 ZVRK Safety switch with separate actuator / AZ 15 Preferred typ thermoplastic enclosure Double-insulated Long life 52 mm x 75 mm x 30 mm Multiple coding Large wiring
More informationData sheet C6 A modul 1 port 180 M AP pure white
Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component
More informationL.V. Systems & Solutions
GE Energy Industrial Solutions L.V. Systems & Solutions Residential Components & Distribution Boards Home & Building Automation Industrial Breakers General Purpose Enclosures System Enclosures Control
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationALPHA SIMBOX Small Distribution Boards
ALPHA SIMBOX Small Distribution Boards /2 Introduction /3 Introduction /4 Flush-mounting and hollow-wall distribution boards /5 Surface-mounting and hood-type distribution boards /6 Accessories /7 Dimensional
More informationDatasheet - AZ 16ZVRK
Print - Create PDF - Create EXCEL file - Hide system components 21.04.2011-12:09:14h Datasheet - AZ 16ZVRK Safety switch with separate actuator / AZ 16 thermoplastic enclosure Double-insulated Large wiring
More informationMINI-PS AC/10-15DC/8
Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a
More informationTYPE 4/12 PREMIER SERIES
Type 4 / 12 Enclosures TYPE 4/12 PREMIER SERIES ENCLO- Contemporary Contemporary Design Design Seamless Seamless Foam-In-Place Foam-In-Place Gasketing Gasketing Utility Utility Brackets Brackets for for
More informationDatasheet - SRB 301LC/B-24V
27.01.2016-00:27:16h Datasheet - SRB 301LC/B-24V Guard door monitors and Safety control modules for Emergency Stop applications / General Purpose safety controllers (Series PROTECT SRB) / SRB 301LC/B Fit
More information