Renovo Zhuhai Ltd. is the research partnership of China Mobile. Many of field giants have
|
|
- Jemima Thornton
- 5 years ago
- Views:
Transcription
1
2
3 About us We established Renovo Zhuhai Ltd. at the end of 2007, which specializes at the research & development, design and manufacture of precision air conditioning Renovo Zhuhai Ltd. is the research partnership of China Mobile. Many of field giants have been following China Mobile s study results. We have approved by ISO9001, ISO14001 and GB/T Renovo s emphasis on products quality and environmental sustainability has paved the way for CCC certification, CE certification, UL certification for some models, lots of patents and energy efficient products.
4 History At the same year 2007, start to make coils 2008 we signed a joint research agreement with Shanghai Jiao Tong University Coil Then, start to manufacture the precision air conditioner Precision Air conditioner
5 Our Strategy Simplicity Efficiency because simplicity Speedy Fast Customer response Fast and accurate delivery Servicing Provide our customer with 24-hours around the clock service Everything is for the customer and market need
6 Key Facts About Renovo 2 branches and 13 offices in China Manufacture area: 12,500m2 (Three workshops) Large-scale comprehensive R&D laboratory (Over 20 staffs) Production Capacity: 10, sets/ Year Products sold areas : USA, Russia, Korea, Holland, Portugal,UAE, Singapore, Thailand, Vietnam, Malaysia, Mongolia,Sri i Lanka, Colombia, Venezuela, Peru, Bolivia, Hongkong, Macau, Niger, Iraq, Bangladesh(110 sets 32Kw chilled water in row cooling), Pakistan, Iran etc
7 PRODUCT Heat exchanger Closed control air condition Base station air condition Renovo IT solution Air-cooled screw free-cooling chiller
8 Our Business Scope
9 Heat exchanger Highly efficient heat exchanger TURBO Evaporator a o Tube adopted with high-quality materials and advanced professional technology. It has a larger area of heat transfer Φ9.25 and Φ7 series of heat exchangers: finned-tube type condenser, evaporator Various application Condenser and Dry-cooler
10 Closed control air condition
11 Cooling capacity Cooling capacity 6KW~125KW
12 Air-cooled DX units Cooling capacity: 6.0~120kw Two types of evaporator configuration: P type and V type Humidifying Range:3~8 kg/h Heating Range: 2~24 kw (optional up to 27kw) Air cycle Range:1800~30000 m3/h R22 refrigerant is standard. R407c and R410a refrigerant are optional Down flow and up flow air supply Our air-cooled direct expansion units take the heat from indoor and transfer it into outside by using condenser. The indoor unit and condenser would become a closed circuit after completed installation. It fits for the areas where lack of water or cooling water system P type V type
13 Chilled water units Cooling capacity:8~125kw Two types of evaporator configuration: P type and V type Humidifying Range:3~30 kg/h Heating Range: 2~40 kw Air cycle Range:1580~42000 m3/h Down flow and up flow air supply Water coming generally from a chiller is used in these units to transfer the heat. The flow of liquid through the unit water coil is controlled through an internal 2 or 3-way valve. The unit is normally used in the place where owns chilled water system
14 Standard Component All the components must be tested strictly before used in factory
15 Optional 1.Up-flow air hood 2.Smoke/fire detectors 3.Point/belt leakage detection system 4.Screen touch display 5.Thermotic expansion valve 6EC 6.EC fan 7.Install fan under raised floor Special Orders
16 A variety of network control Electronics standard functions Graphic display Programmable software General alarm Automatic reset after blackout Record storage of 100 alarms Standby management Automatic rotation Serious alarms Total communication In a policy of total communication we offer various solutions for interconnection to the most modern BMS, aimed at satisfying varying needs. Firmware protocol for total management of all the air conditioning parameter, including: Detection and transmission of alarms from remote Various protocol adaptable: Modbus, BAC net, Lonworks, SNMP and etcs. Recording of data and alarms Sending of SMS via GSM modem Our control System
17 Energy-saving unit after customized DC Inverter RTR air condition Cooling capacity:10kw Refrigerant:R410a DC inverter compressor CE&ETL certification Atomizer can improve condensing efficiency DC inverter compressor
18 High-efficiency unit after customized COP reach into 3.0 after optimize the inner structure V type structure coil EC fan V type Tailored high-efficiency unit for China Mobile
19 Base station air condition Cooling capacity 6~24KW Base stations air condition is specially designed for small communications room, a small IT rooms, mobile communication base station development. Provide the greatest reliability, the highest level of operational efficiency and precise temperature control and good energy-saving for high-tech telecommunications equipment Small Space: equipment design is reasonable and compact Applicability: Products take many forms to choose, such as split type
20 IT solution
21 Row to Row air condition DX air-cooled monoblock RTR units DX air-cooled split RTR units Cooling capacity: 5~20KW Cooling capacity:6.5~45kw Chilled water RTR units Cooling capacity: 20~50KW Refrigerant: R410a Standard 42U cabinet Coupling compressor unit Variable speed EC fans Optional: 1. Humidification control 2. Electrical heater 3. Condensate pump 4. Water leakage detector 5. RS485 Modbus card
22 Monoblock RTR air condition Our DX air-cooled monoblock RTR unit is a self-contained air conditioning unit housed in a standard 42U enclosure. It is optimized for general computer room cooling or supplemental l cooling in a large server room. It features a world famous compressor that delivers high-efficiency precision cooling. Model Name MUA 005AH 010AH 015AH 020CH Input V/Ph/H z 220/1/ /3/ /3/ /3/50 60 Total Cooling Capacity kw Scroll Compressor Touched Screen Controller Unit Dimension (D*W*H) mm 300*1050* *1100* *1100* *1100* Weight kg Color black Form Factor Tower(42U equivalent) Air Filters G4 G4 G4 G4 Noise Level db(a) R410a Refrigerant
23 Integrated solution for data center Micro modular Data center in a box
24 Integrated solution for data center 10KW split type 5KW mono block type
25 Air-cooled screw free-cooling chiller IT technology grows fast, and the data center has become an inevitable product due to data central tendency. As a large number of new rack server and blade server had been used in the data center, and the thermal density reached 30-40KW per cabinet, so common air-conditioning system has been unable to meet the cooling requirements of high-density heat dissipation room. Now the data center needs a new type of efficient, energy-saving, manageable computer room solutions urgently, that s why Our s RFAW free-cooling screw chiller emerged. Cooling capacity 200~1500KW Efficient semi-enclosed enclosed twin-screw compressor the EER> 4.8 Classification of compressor control 25%, 50%, 75%, 100% variable load operation International advanced cooling power distribution components: ABB, Schneider, Danfoss Advanced natural cooling techniques Wide range of ambient temperature -15 ~48 R22 R134a R407c refrigerant is optional
26 Air-cooled screw free-cooling chiller Summer or hot weather: Chiller unit start-up and its compressor operated for cooling mainly Transitional season of spring and autumn or cool weather: When the ambient temperature is lower two degrees Celsius or above than the temperature of the returned chilled water (the temperature difference can be manually adjusted, but not recommended lower than two degrees Celsius), open three-way valve in the system, and then the system automatically turns on free- cooling refrigeration. Once the free-cooling can not meet the requirement, compressor refrigeration will be turned on for supplement Refrigeration theory Winter or cold weather: e with the decrease ease of the 1.Compressor 2.condenser ambient temperature or the indoor heat load 3.nature cooling heat exchange reduction, free-cooling system gradually increases coil 4.EXV 5.3-way adjustable the proportion of its refrigeration until completely valve 6.shell-and-tube evaporator using free-cooling, and then we can stop the compressor refrigeration
27 Laboratory Testing Ability *Qualified by the national level certificate from General Technology Research Institute in He Fei. *Max. capacity is160kw for precision air conditioner *Able to test t heat exchange coil (condenser & evaporator) * Able to simulate environment temperature range:5 ~ 40, Relative humidity 10% ~ 90% *Outdoor environment temperature: -40 ~ 55 Testing Item *Cooling/Heating capacity *Cycling air volume Atmosphere Pressure Outlet air static pressure *Injector pressure difference *Enthalpy difference *Sensible/latent cooling capacity *Total heat exchange volume *EER/COP *User site ability *Water resistance, water flow rate *compressor Hi/Low pressure *compressor Suck/return temperature *Power Voltage Current Input and Factor
28 Super High/Low Temp. Lab. Lowest temperature reach - 40 Able to test the unit operation under low temperature environment
29 Laboratory Qualified Certification No. for our Lab. RZ-ZL
30 Research & Development Every yyear invest 6% or more of our turnover into R&D Design mobile station air conditioner for China g mobile company, average 25% energy saving
31 Research & Development 2009 We develop the first 120KW air cooled direct expansion system in the market
32 Research & Development 2009 We develop the mono block air system and got the patent
33 Research & Development Mono block station air
34 Market - references Renovo Zhuhai Ltd.
35 Communication system China Telecom China Mobile Communication Corporation China Unicom
36 Railway system China Railway Group Jinjing Railway Wuguang high-speed rail Baocheng Railway Jinhu high-speed rail Haxi railway
37 Hospital system Second People's Hospital of Guangdong Province Affiliated to Shandong University reproductive hospital Shanghai Construction Hospital Danyang City People's Hospital
38 Culture& education system State Sports General Administration University of Science and Technology of China Art Museum of China Shanghai Longhua Temple
39 Aerospace system Shanghai Pratt & Whitney (PW) Engine Company Shanghai Aircraft Manufacturing Company Xichang Satellite Center Hangzhou Xiaoshan Airport Tianjin zhonghang helicopter flight
40 Finance & Bank system Guangdong Pacific Insurance Rural Credit Cooperatives Taizhou HuaXia bank China GuangDa bank
41 customers----financial institutions and banks 韶关银监局 泰隆银行宁波分行 邳州市农村信用合作社 东吴期货有限公司 泰隆银行台州分行. 杭州分行. 宁波分行. 丽水分行. 衢州分行 广东太平洋保险 奎屯市商业银行 江苏建湖农村信用社 南京光大银行 承德银监局 台州华夏银行 上海银联 Banks financial institutions Banking Regulatory Commission
42 Electrical power system Huzhou Electric Power Bureau Zhoushan Power Authority Taishun Power Authority Stone hole thermal power plant Sichuan Deyang Dongfang Steam Turbine Works Wenzhou Yongjia Power Authority Nanchong Power Administration Yangzhou City Power Supply Company
43 Oil & Petro. system Yangzi petrochemical Qidong LNG refining project Guangxi tiandong oilfield Langfang WanZhuang oil four factory Iraq Halfaya oil field
44 Broadcast & TV system Z h TV b d t t ti Zengcheng TV broadcast station Chinese movie channel Guangdong southern media Guangzhou radio and television university Zhejiang XingHua broadcaster Dunhuang limited television station Shandong television Quanzhou people's broadcasting station
45 Meteorological system The national satellite meteorological center The Beijing meteorological bureau Jilin meteorological administration Shanghai meteorological information and technology support center Weather modification office in liaoning province Shanxi meteorological information center The state oceanic administration environment monitoring center of the east China sea States people's broadcasting station
46 Others--- Abroad 3M building in bankok Government building in Thailand Niger 20+sets base station air con Sino favour centre HK
47 Others--- Abroad JB TM Data center in Malaysia Iraq Halfaya oil field Bangladesh IV Tier National Data Center
48 Others--- Abroad USA ODM monoblock inrow cooling Thailand Telecom Ericsson Ltd. in Hongkong Meadville Enterprises (HK) Ltd. Queen Elizabeth Hospital Hong Kong Government office Samsung Securities Projects in Singapore: MSF/SPH/Sentosa Fire Station/NTUC Income/ASTAR NSCC/ING/Media Data Systems/NTU CIMB bank in Malaysia FIFA World Cup 2018 in Moscow
49 CUSTOMER REFERENCE.
50 CUSTOMER REFERENCE.
51 OUR PARTNERS
52
ZTE ZXCR Series DX In-Row Air Conditioning Product Description
ZTE ZXCR Series DX In-Row Air Conditioning Product Description Requirements & Challenges Due to the rapid development of telecommunication technology, the related IT equipment s power consumption is increase
More informationHuawei Smart Cooling Solution
Huawei Energy Powering the Future Huawei Smart Cooling Solution HUAWEI TECHNOLOGIES CO., LTD. To meet increasing demands of data centers such as IT business integration, virtualization and cloud computing,
More informationPT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone
PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 0 Jl. Malibu Raya, Cengkareng Jakarta Barat 70 Indonesia Phone + 4 4 www.climanusa.com Marketing features prominent presence on the world
More informationProduct Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres
Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how
More informationRack cooling solutions for high density racks management, from 10 to 75 kw
Rack cooling solutions for high density racks management, from 10 to 75 Superior efficiency, high reliability, low energy consumption Modern data center are characterized by 24/7 operation all year long.
More informationCHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw
IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING
More informationHIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.
HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM. SYSTEM LOGICA is the most advanced alternative to the problem of cooling of server rooms MONTAIR is the trademark which represents excellence on the market
More informationSmoothAir Modular Precision Cooling
TM SmoothAir Modular Precision Cooling ODM/OEM/Customization+ Specialist Support+ Modular Precision Cooling for Smart, Reliable and Green MDC Solution Why Choose Us Products Support Customization Products
More informationLiebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets
Liebert DM High Performance, Sensible Cooling for Small Computer Rooms and Network Closets Emerson Network Power, a business of Emerson (NYSE: EMR), is a worldwide leader in infrastructure solutions across
More informationMission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire
Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101 Nick Gangemi Regional Sales Manager Data Aire Agenda Exactly what are we talking about ASHRAE TC 9.9 Design best practices
More informationIT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw
IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE
More informationCHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT
CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT DYNACIAT: HIGH PERFORMANCE HEATING AND COOLING FOR MEDIUM-SIZED BUILDINGS To better meet customer needs and answer environmental
More informationAiredale International Air Conditioning Limited. Leeds Road, Rawdon Leeds, LS19 6JY, England
> For the latest information on our products please visit : www.airedale.com > Please refer to the technical manuals for more detailed information Your nearest Airedale distributor is: ISO 14001 EMS52086
More informationglide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA
99 glide air cooled liquid chillers ND free cooling chillers glider 178 1328 Energy Class More efficient + B C D E F G Less efficient R134a CLSS SHELL C E C FREE COOLING 100 air cooled liquid chiller and
More informationLarge Tonnage Chillers. Kingsley Hu Technical Support Engineer
Large Tonnage Chillers Kingsley Hu Technical Support Engineer Chongqing Plant Chiller Products Reference Projects Manufacturing Facility Major Milestones Global R&D Talent Production Line introduction
More informationSTULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling
STULZ Micro DC with Chip-to-Atmosphere TM Liquid to Chip Cooling STULZ Micro DC Data center professionals and communication service providers (CSPs) face an increasingly difficult world. The continued
More information2018 Product overview
2018 Product overview Project conditioning Evolution goes on During these years, the activity of EMICON has been developed with the production of liquid chillers for conditioning and industrial applications,
More informationPrecision Cooling. Precision Cooling Advantages
Precision Cooling Today s computing technologies compound conventional cooling problems. Blade servers, communications switches and other electronics are being packed into tighter and tighter spaces. Computing
More informationData Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,
More informationImplementation Plan for Pilot Projects of Green Data Centers Issued by MIIT. Jiaying Song Chinese Institute of Electronics
Implementation Plan for Pilot Projects of Green Data Centers Issued by MIIT Jiaying Song Chinese Institute of Electronics Outline Background Brief Introduction Goals Work of the Scope Pilot Projects Introduction
More informationIT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw
IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable
More informationAquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.
Aquaflair Uniflair TRAC, TRAF and TRAH Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors 120-350kW Uniflair TRA ranges 115-350kW Air-cooled Chillers Cooling, Free cooling
More informationCOMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012
MCAC-2012-37 COMMERCIAL AIR CONDITIONERS 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner department,
More informationCooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS
Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data
More informationDATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise
DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise TWO STAGE POWER DISTRIBUTION Executive Summary Today s data centers are changing rapidly, and it is more important than ever
More informationEcotel Free Cool 5-15kW
Precision Air Conditioning Free-cooling Ecotel Free Cool 5-15kW + + Self-contained compact outdoor cabin cooler + + 100% free-cooling + + -48V DC supply option + + Easy serviceability (front component
More informationFuture of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power
Future of Cooling High Density Equipment Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power Agenda Issues facing the Data Center Managing the explosive
More informationAquaflair. BREC & BREF kW 380V/3ph/60Hz - 460V/3ph/60Hz. Air-cooled chillers and free-cooling chillers with double screw compressors
Aquaflair Air-cooled chillers and free-cooling chillers with double screw compressors BREC & BREF 350-1200kW 380V/3ph/60Hz - 460V/3ph/60Hz The all-in-one solution for your business need Combining cutting-edge
More informationEcoflair Air Economizers
Ecoflair Air Economizers Cooling to maximize value for the cloud schneider-electric.com/ecoflair Life is On Schneider Electric 1 Ecoflair takes data center efficiency to new heights 2 Imagine cooling your
More informationPrecision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers
Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited
More informationLiebert DM. High Performance, Sensible Cooling for Small Computer Rooms and Network Closets
Liebert DM High Performance, Sensible Cooling for Small Computer Rooms and Network Closets Emerson Network Power, a business of Emerson (NYSE: EMR), is a worldwide leader in infrastructure solutions across
More informationIT Air Conditioning Units
IT Air Conditioning Units Modern Flexible Effective Energy Saving CoolTeg Plus and CoolTop overview CoolTeg Plus CW CoolTeg Plus DX CoolTeg Plus XC CoolTop Installation Between IT racks On top of IT rack
More informationMOLLIER DIAGRAM CAN BE IMPROVED!
MOLLIER DIAGRAM CAN BE IMPROVED! IMPROVED BASIC COOLING CIRCUIT PERFORMANCE EFFICIENCY USING AN ECONOMISER Eng. Jonny Malachi, VP Operations, Mashav Refrigeration and Air Conditioning Engineering Ltd.
More informationClose-coupled cooling
Close-coupled cooling Intelligently controlled high-performance InRow cooling for the IT environment APC TM by Schneider Electric close-coupled cooling products provide a modular, scalable, and predictable
More informationMSYS 4480 AC Systems Winter 2015
MSYS 4480 AC Systems Winter 2015 Module 12: DATA CENTERS By Satwinder Singh 14/05/2015 1 Data Centers Data Centers are specialized environments that safeguard your company's most valuable equipment and
More informationReliability and extended operation
CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter
More informationWelcome Association of Energy Engineers to the Microsoft Technology Center
Welcome Association of Energy Engineers to the Microsoft Technology Center Today s Agenda 10:00 10:30 What s new in data center energy efficiency planning and implementation? 10:30 11:00 ASHRAE data center
More informationGreen Data Centers A Guideline
Green Data Centers A Guideline Sekhar Kondepudi Ph.D Associate Professor Smart Buildings & Smart Cities Vice Chair Focus Group on Smart Sustainable Cities ITU-TRCSL Workshop on Greening the Future: Bridging
More informationMEASURE MONITOR UNDERSTAND
MEASURE MONITOR UNDERSTAND Presented by Alistair Hunt Energy Monitoring, Measurement metrics Where and What 1 History & Background Company Timeline 18 Years Comrac & Sinetica founded 15 Years Raritan Integration
More informationMotivair MLC-SC Air-Cooled Scroll Chillers Tons
INNOVATE DESIGN APPLY www.motivaircorp.com Motivair MLC-SC Air-Cooled Scroll Chillers 100 285 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Businesses who function in today s advanced
More informationEfficiency of Data Center cooling
Efficiency of Data Center cooling Comparison of data room layouts and cooling systems Bohumil Cimbal Product manager for Cooling Systems in CONTEG Company Objective Basic questions between investor and
More informationPrecision Cooling Mission Critical Air Handling Units
M I S S I O N C R I T I CA L C O O L I N G Precision Cooling Mission Critical Air Handling Units Global Expertise for Precision Cooling Solutions STULZ is a privately owned, global manufacturer of highly
More informationCTC Low Temperature Process Chillers
INNOVATE DESIGN APPLY CTC Low Temperature Process Chillers 5-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough When it comes to process cooling, every application is unique in
More informationYour Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant
Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,
More informationA Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System
A Data Center Heat Removal System That Saves... Infrastructure Power Water up to 40% up to 80% up to 85% Discover Inertech s Award-winning Data Center Heat Removal System A Cool Solution; A Breakthrough
More informationPEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers
TM PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable
More informationDrives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)
Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to
More informationDATA CENTER MEETING ALL POWER REQUIREMENTS IN THE DATA CENTER
DATA CENTER MEETING ALL POWER REQUIREMENTS IN THE DATA CENTER DO YOU HAVE THE POWER TO GROW YOUR DATA CENTER BUSINESS? Data center operation is a no compromise business. Customers are buying peace-of-mind
More informationFeatures and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions
Controls Guide for XeteX Units Beyond meeting the typical specification and performance requirements, controlling the equipment is usually the most important success factor for HVAC projects. XeteX provides
More informationUPS. centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw INFINITE POWER. Mission Critical Applications
INFINITE POWER Mission Critical Applications UPS UNINTERRUPTIBLE POWER SUPPLY centric Hot scalable modular 3-phase UPS Delivers 25 up to 200 kva/kw Rack-mountable modules designed for blades, data-center,
More informationMAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION
MAKING MODERN LIVING POSSIBLE REFRIGERATION & AIR CONDITIONING DIVISION ADAP-KOOL Drive A New Drive for Energy Efficiency AKD 102 2 The AKD 102 comes with a common user interface and covers power ratings
More informationApplication of Green Technology For Data Centre
Application of Green Technology For Data Centre Steven So Vice President Data Centre Business Cloud Business Division NTT Com Asia Limited 25 Sep 2013 Today s Agenda Why? How? What? Business Drivers
More informationData Center Optimized Controls
Data Center Optimized Controls Controls Agenda 30 min. Emerson Control Products icom (Dynamic Thermal Optimization) 20 min. Station Rotation Station 1: Controller Challenge Station 2: Wireless Demo 5 min.
More informationPerformance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot
Performance Certification : From Energy Efficiency To Indoor Air Quality By: Eric Foucherot Certified Products for Efficient & Safe Design Certified Performances for HVAC&R Product AIR CONDITIONERS CHILLERS
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure,
More informationWe design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our
We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our clients requirements and with the lowest environmental
More informationChilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers
Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens
More informationLiebert HPM from 4 kw to 100 kw
Precision Cooling for Business-Critical Continuity Liebert HPM from 4 kw to 100 kw Efficient Direct Expansion Cooling for Data Centers With R410A Refrigerant Whether a data center houses three or 200 IT
More informationDrives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)
Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to
More informationCLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit
CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW The indirect evaporative free-cooling Air Handling Unit Flexible & Efficient 11 sizes from 30 kw up to 520 kw to fit your needs with maximum efficiency
More informationAIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS
RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.
More informationCommunication Register Map - Uniflair Cooling
DIGITAL 0 1 1 - - - - DIGITAL 1 2 2 System On (Fan) 0 or 1 boolean R DIGITAL 2 3 3 Compressor 1 0 or 1 boolean R DIGITAL 3 4 4 Compressor 2 0 or 1 boolean R DIGITAL 4 5 5 Compressor 3 0 or 1 boolean R
More informationPassive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer
Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling Jeremiah Stikeleather Applications Engineer Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling While CRAH cooling has been
More informationLiquid Cooling Package LCP Cooling Systems
Liquid Cooling Package LCP Cooling Systems 2 Rittal LCP Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative
More informationIndirect Adiabatic and Evaporative Data Center Cooling
Indirect Adiabatic and Evaporative Data Center Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced technology
More informationLiebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability
Precision Cooling for Business-Critical Continuity TM Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability DATA CENTER SOLUTIONS For More Information:
More informationLiebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY.
Liebert DSE Precision Cooling System Industry-best efficiency. Increased capacity. Ensured availability. EFFICIENCY. CAPACITY. AVAILABILITY. Liebert DSE High-Efficiency Precision Cooling System Room-Based
More informationInstallation Service. 1.0 Executive Summary. Factory Trained Technician Train Customer Support Staff On Basic Operation Of The Equipment
Installation Service Statement of Work Start-up Service for Cooling Start-up - 1 - Service for Cooling Service 1.0 Executive Summary Table of Contents 1.0 Executive Summary 2.0 Features & Benefits 3.0
More informationLiebert. PDX from 15 to 165 kw. Direct Expansion Solution for Small and Medium Data Centers
Liebert PDX from 5 to 65 Direct Expansion Solution for Small and Medium Data Centers LIEBERT PDX from 5 to 65 Vertiv Vertiv designs, builds and services mission critical technologies that enable the vital
More informationMLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MLC Air-Cooled Chillers MLC-FC Free-Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons OUR BUSINESS IS COOLING YOURS TM When commercial grade isn t enough
More informationAIR COOLED HEAT PUMPS WITH SCREW COMPRESSORS AND AXIAL FANS
PAH 2802 T K AIR R-407C R-134a Series PAH... T K from 205 to 778 kw - 2 circuits The air cooled heat pumps of PAH.T series are designed for outdoor installation and are particularly suitable for industrial
More informationLiebert. DSE Thermal Management System Free Cooling Economization Without Using Water
Liebert DSE Thermal Management System Free Cooling Economization Without Using Water LIEBERT DSE THERMAL MANAGEMENT SYSTEM Liebert DSE System Overview A Highly Efficient, Self-Optimizing Solution for Thermal
More informationThermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.
Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or
More informationRack & Enclosure Systems
Knürr CoolTherm 4 35 KW Energy-efficient Server Cabinet Technology With Outstanding Benefits, To Minimize Energy Costs In The Data Center And Help Reduce Carbon Dioxide Emmisions Rack & Enclosure Systems
More informationPEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers
TM PEX (R410A) High Efficiency, Green Solution Precision Cooling for Data Centers WE ARE VERTIV Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that
More informationSwitch to Perfection
Switch to Perfection Traditional Data Centre - Temperatures Ideal Air Temperature: 22 C Chilled Water: 7-9 C Heat Load per Rack: Up to 4,5 Chilling & Pump Set The challenge a thermal image Front View of
More informationIndirect Adiabatic and Evaporative Data Centre Cooling
Indirect Adiabatic and Evaporative Data Centre Cooling Developed in response to the broadening of the ASHRAE recommended server inlet temperature envelope in 2008, Excool represents the most advanced
More informationScalable, Secure. Jason Rylands
Energy Efficient, Modular, Scalable, Secure Jason Rylands The planning, construction and operation of IT infrastructure for mission critical applications in reliable Datacentres represents a real challenge.
More informationEDGE LM XLMA Series Data Module
TM TM EDGE LM XLMA Series Data Module The EDGE LM Data Modules can be deployed indoors or outdoors and have been designed to provide density and rack adaptable IT space for environments enabling low to
More informationTrailblazer AGZ-E air-cooled scroll chillers
Trailblazer AGZ-E air-cooled scroll chillers 30 to 240 tons with Variable Speed Condenser Fan Technology The right features, the right value, right now Intelligent Equipment AGZ-E 30 to 161 RapidRestore
More informationLiebert PDX from 15 to 120 kw
Liebert PDX from 5 to 0 kw The Thermal Management Solution for Small and Medium Data Centers Electronic Expansion Valve Efficiency Digital Scroll Partial Load icom TM Control TCO Optimization Integrated
More informationLEADERS IN MEP, COMMISSIONING & ICT FOR BOSTON AND THE NORTHEAST
LEADERS IN MEP, COMMISSIONING & ICT FOR BOSTON AND THE NORTHEAST SYSKA BOSTON provides full-range, high-performance MEP/FP engineering, vertical transportation, sustainable design and commissioning services
More informationThe Main Issues and the Game Changing Concepts of Chinese Economy
The Main Issues and the Game Changing Concepts of Chinese Economy Syed Hasanat Associate Professor Jilin University 1 Connectivity and integration Belt and Road Initiatives Unimpeded trade Facilitate connectivity
More informationChiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw
Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote
More information上海科晗实业有限公司 SHANGHAI KEHAN INDUSTRIAL CO.,LTD.
上海科晗实业有限公司 SHANGHAI KEHAN INDUSTRIAL CO.,LTD. Brief Introduction Shanghai Kehan as known as brand name 'Rainbow' is one of the professional manufacturer of surge protective device in China. Currently,
More informationFEATURES AND BENEFITS. Installation and operation. Controller
DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.
More informationMPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers
INNOVATE DESIGN APPLY www.motivaircorp.com MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers ½ - 100 Tons OUR BUSINESS IS COOLING YOURS. When commercial grade isn t enough Motivair is a world-class
More informationLiebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW. AC Power For Business-Critical Continuity
Liebert APM The Compact Row-Based UPS With Flexpower Technology TM 30kW - 300kW AC Power For Business-Critical Continuity Emerson Network Power, a division of Emerson, is a global company that combines
More informationLiebert DCW CATALOGUE
Liebert DCW CATALOGUE Chilled Water-Based High Density Cooling For The Data Center LIEBERT DCW Flexible Approaches For Energy Efficient Cooling Save up to 70% in cooling energy usage Data center managers
More informationLiebert PDX from 15 to 120 kw
Liebert PDX from 5 to 0 kw The Thermal Management Solution for Small and Medium Data Centers Electronic Expansion Valve Efficiency Digital Scroll Partial Load icom Control TCO Optimization Integrated Solution
More informationRichmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green
Richmond Heights Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller Presentation Agenda 1. Introduction To Richmond Heights 2. Smart Universal Controller Features Of DAS-G01 3. DAS-G01
More informationHigh Efficient Data Center Cooling
Nordborg High Efficient Data Center Cooling Copenhagen Center on Energy Efficiency webinar 12. July 2017 Jörg Saar, Danfoss Cooling 1 Danfoss Cooling Contents 1. Short intro to Danfoss Cooling 2. Introduction
More informationGP SERIES Packaged Chillers
Blending Conveying Drying Process Cooling Heat Transfer Size Reduction GP SERIES Packaged Chillers Comprehensive Flexible Versatile Compact unitary designs available in a variety of configurations from
More informationT66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management
T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management Name Doug Demian Title Application Engineer Date November 7 & 8, 2012 Rev 5058-CO900C Copyright 2012 Rockwell
More informationLiebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability
Liebert AFC from 500 to 1700 kw The Adiabatic Freecooling Solution with Top-Tier Availability Liebert AFC from 500 to 1700 kw Vertiv Vertiv designs, builds and services mission critical technologies that
More informationRAILWAY & METRO MEETING ALL POWER REQUIREMENTS ALONG THE TRACK
RAILWAY & METRO MEETING ALL POWER REQUIREMENTS ALONG THE TRACK do you have the power to take your raıl servıce ınto the future? Safety, timeliness and efficiency are the hallmarks of high quality train
More informationi-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw
i-accurate_gb_07-2011 igh precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 Coming form 40 years experience in air conditioning and
More informationVariable Speed IPLV.36 kw/tr
ACEGWFVXR Series 50 Hz Energy Efficient Variable Speed Water-Cooled Screw Chillers 3 Range from 00 TR to 00 TR Variable Speed IPLV.36 kw/tr GREEN EFFICIENT SUSTAINABLE ACEGWFXR Series 50Hz Energy Efficient
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP KP switchs are for use in refrigeration and air conditioning systems to give protection against excessively low suction or excessively high discharge. KP switches are also
More informationINNOVATE DESIGN APPLY.
INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues
More information