Johnson Controls York Acoustics

Size: px
Start display at page:

Download "Johnson Controls York Acoustics"

Transcription

1 Johnson Controls York Acoustics If you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail and select reset slide or choose the Reset button on the Home ribbon (next to the font choice box) If you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail and select reset slide or choose the Reset button on the Home ribbon (next to the font choice box) R. Troy Taylor Sound and Vibration Engineer CAV Spring Conference 2017

2 Acoustics Team at Johnson Controls York About me BS Physics, Brigham Young University 2011 MS Acoustics, Penn State University years as an acoustics engineer at Johnson Controls About our Team Engineering services team led by Pat Marks Sound and Vibration team managed by Dale Unger Four full-time engineers Two part-time consulting engineers (retired JCI employees) Two full-time technicians Air handling unit acoustics team led by Curt Eichelberger Two full-time engineers 2

3 Johnson Controls creates intelligent buildings, efficient energy solutions, and integrated infrastructure that work seamlessly together to deliver on the promise of smart cities and communities. Power Solutions Buildings Batteries HVAC Equipment Distributed Energy Storage Security and Fire Safety 3

4 The acoustics and vibration team performs research, product development, testing and evaluation geared to creating and sustaining quiet and reliable chillers and air handling systems for our customers. Variable Geometry Diffuser Varies Width to Match Changing Flow Pin & Diffuser-Ring Motion 4

5 At our current York facility we have a variety of test facilities for acoustic testing of water-cooled chillers, air-cooled chillers and air handling units 5

6 Two hemi-anechoic chambers used for testing water cooled chillers Laboratory Specifications: Large Hemi-Anechoic room: Volume: 41,000 cu-ft TR loading capability Door clearance: 18 wide x 16 high. Room floating on 41 ½ static deflection isolators. 1.7 million pound building weight. Room Qualification to 50 Hz. Small Hemi Anechoic Room: Volume: 18,000 cu-ft. 400 TR loading capability Mechanical Support Equipment Isolation. Special capability: Simultaneous testing of thermal and sound performance in a hemi-anechoic environment. Noise signature testing for US Navy chillers. 6

7 Water cooled chiller measurements done according to AHRI 575 using Mueller BBM data acquisition system AHRI 575 is a method of measuring machinery sound within an equipment space 7

8 There is also a hemi-anechoic room used for acoustic testing of aircooled chillers Laboratory Specifications: Hemi-Anechoic room: Volume: 38,000 cu-ft. 340,000 CFM Quiet Air Supply Support Equipment > 400 TR loading capability Mechanical Support Equipment Isolation Special capability: Simultaneous testing of thermal and sound performance in a hemi-anechoic environment Measurements done according to AHRI Standard 370 8

9 Statistical Energy Analysis models are used for noise predictions of products in development and for changes to existing products SPL Measured Predicted Frequency (Hz) Software: ESI VA One Internal compressor pulsation measurements used as inputs to the model 9

10 Air-handling unit testing Laboratory Specifications: Reverberation room: Volume: 105,000 cu-ft. Apertures: 12 x 12 and 8 x 8 (for duct connections). Door clearance: 14 wide x 14 high (for casing radiated sound). Silencers sized to pass air through the Rev. Rm. (< 0.2 iwg pressure at 100,000 cfm). Analyzer with dual rotating microphone booms for sound measurement. Code Testers: 100,000 cfm code tester, rated at 9 iwg, turn-down to 10% of flow. 30,000 cfm code tester, rated at 9 iwg, turn-down to 10% flow. Special capability: Simultaneous testing of air and sound performance. Test fully assembled AHUs. Test packaged equipment (rooftops, floor-by-floors) Test Standard AHRI

Position Title: H V A C T E C H N I C I A N. G.E.D. or High School Diploma required, an Associate s Degree is preferred.

Position Title: H V A C T E C H N I C I A N. G.E.D. or High School Diploma required, an Associate s Degree is preferred. Location Beeville-Primary; All Campuses Hours 40 hours/week minimum Salary $40,000-$50,000 annual, based on KSAs Job Classification Exempt Security Sensitive Y e s Division Physical Plant Department Physical

More information

CONTROLLING ROOFTOP UNIT (RTU) NOISE

CONTROLLING ROOFTOP UNIT (RTU) NOISE HUSHCORE Acoustical Products & Systems Technical Discussion General Information Terminology & Definitions Product Types Treatment Strategies Applications/Uses Industrial Architectural HVAC OEM Environmental

More information

Consultancy along with installation for Air Conditioning System and expertise in Clean Room Systems.

Consultancy along with installation for Air Conditioning System and expertise in Clean Room Systems. +91-9350861515 +91-9560390369 Experts In HVAC & CLEANROOMS Perfect Air www.indiamart.com/perfectair www.perfectair.in Consultancy along with installation for Air Conditioning System and expertise in Clean

More information

DUCTED SPLIT SYSTEMS With Scroll compressors

DUCTED SPLIT SYSTEMS With Scroll compressors DUCTED SPLIT SYSTEMS With Scroll compressors 2 Benefits TOTAL COMFORT ON WIDE AREAS The Ducted Blower Split Systems for light commercial applications of DXDXT-M/K series are the ideal solution for keeping

More information

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft. [Reference Design 64] 2000 kw, Tier 3, Chilled Water, refabricated, 23700 sq. ft. DESIGN OVERVIEW Data Center IT Capacity 2000 kw Target Availability Tier 3 Annualized E at 100% Load 1.64 in Miami, FL

More information

Rooftop Unit System Solution. for noise, vibration, and seismic/wind effects

Rooftop Unit System Solution. for noise, vibration, and seismic/wind effects Rooftop Unit System Solution for noise, vibration, and seismic/wind effects Rooftop Units Noise Problems RTUs are currently the most common cause of noise in HVAC, and thus a major reason for tenant complaints.

More information

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser 12 in. x 12 in. Face 4 Neck Velocity (fpm) 400 00 00 00 00 900 00 1200 1400 0 Velocity Pressure (in. w.g.)..01.022.031.040.00.02.090.122..013.021.030.041.04.0.04.121.1.21 Flow Rate (cfm) 3 44 2 1 0 4 122

More information

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

3300 kw, Tier 3, Chilled Water, 70,000 ft 2 [Reference Design 22] 3300 kw, Tier 3, Chilled Water, 70,000 ft 2 DESIGN OVERVIEW Data Center IT Capacity 1100 kw per Data Hall 3 Independent Data Halls Design Application Range This design can be applied

More information

REP N BANK ST. ENVIRONMENTAL NOISE STUDY Page 1 of 14

REP N BANK ST. ENVIRONMENTAL NOISE STUDY Page 1 of 14 REP N45 852 BANK ST. ENVIRONMENTAL NOISE STUDY Page 1 of 14 2014-06-02 Robert Matthews, B.ARCH., O.A.A., A.A.N.B., R.A.I.C. N45 ARCHITECTURE INC. 2nd floor, 43 Eccles Street Ottawa, Ontario Canada K1R

More information

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant Your Solution For Energy and Cost Savings McQuay Packaged Chiller Plant Innovative Solutions for Your Chiller Plant McQuay packaged chiller plants provide energy efficient chillers integrated with pumps,

More information

Impact of Sound on Computer Hard Disk Drives and Risk Mitigation Measures

Impact of Sound on Computer Hard Disk Drives and Risk Mitigation Measures Impact of Sound on Computer Hard Disk Drives and Risk Mitigation Measures Introduction to Data Center Acoustic Sensitivity Data centers are relied upon to store and distribute valuable information from

More information

YORK SOLUTION AIR HANDLING UNITS

YORK SOLUTION AIR HANDLING UNITS YORK SOLUTION AIR HANDLING UNITS High-performance indoor and outdoor air handling units from 2,000 120,000 CFM From healthcare to higher education, from office buildings to data centers every project is

More information

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer Large Tonnage Chillers Kingsley Hu Technical Support Engineer Chongqing Plant Chiller Products Reference Projects Manufacturing Facility Major Milestones Global R&D Talent Production Line introduction

More information

The noise of cloud computing

The noise of cloud computing The noise of cloud computing Radek Kochanowski (1) (1) Acoustic Engineer, Aurecon, Sydney, Australia ABSTRACT With Cloud computing and Cloud data storage being sold as the way of the future for storing

More information

200 kw, Tier 3, Chilled Water, 5250 ft 2

200 kw, Tier 3, Chilled Water, 5250 ft 2 [eference Design 4] 200 kw, Tier 3, Chilled Water, 5250 ft 2 DESIGN OVEVIEW Data Center IT Capacity 200 kw Adaptable from 50 kw to 600 kw Target Availability Tier 3 Annualized UE at 100% Load 1.67 in Miami,

More information

Magnitude magnetic bearing centrifugal chillers

Magnitude magnetic bearing centrifugal chillers Magnitude magnetic bearing centrifugal chillers 75-1500 tons Better Air, Better Outcomes Magnitude magnetic bearing centrifugal chillers deliver the energy savings that building owners demand under all

More information

WO P-NF-L-M-407c Spec Submittal

WO P-NF-L-M-407c Spec Submittal WO2-2-10000-2P-NF-L-M-407c Spec Submittal General Specifications WO2-2-10000(801304) Width: IN/CM 136.25/346.07 Height: IN/CM 84.5/214.63 Depth: IN/CM 41.7/105.92 Dry weight: LB/KG 4000/1814.37 Operational

More information

Magnitude magnetic bearing centrifugal chillers

Magnitude magnetic bearing centrifugal chillers Magnitude magnetic bearing centrifugal chillers 75-1500 tons Better Air, Better Outcomes Magnitude magnetic bearing centrifugal chillers deliver the energy savings that building owners demand under all

More information

Temperature/Humidity Agree vibration chambers

Temperature/Humidity Agree vibration chambers Temperature/Humidity Agree vibration chambers CV-Series AV-Series www.cszindustrial.com Vibration Chambers Cincinnati Sub-Zero s AV/CV-Series chambers offer rapid temperature change rates to reduce product

More information

Trane Cold Generator TM. Scroll Chillers. Comfort and Process Cooling Solutions

Trane Cold Generator TM. Scroll Chillers. Comfort and Process Cooling Solutions Trane Cold Generator TM Scroll Chillers Comfort and Process Cooling Solutions Advanced Cooling Solutions The Trane Cold Generator family of scroll chillers is a broad line of comfort and process cooling

More information

DATA CENTER AIR HANDLING COOLING SOLUTIONS

DATA CENTER AIR HANDLING COOLING SOLUTIONS DATA CENTER AIR HANDLING COOLING SOLUTIONS World-class performance and reliability from YORK As data storage and protection needs grow, so can costs and complexity. That s why having the right partner

More information

ROOFTOP UNIT NOISE CONTROL SOLUTIONS

ROOFTOP UNIT NOISE CONTROL SOLUTIONS ROOFTOP UNIT NOISE CONTROL SOLUTIONS NOISE PROBLEMS RTUs are one of the most common causes of HVAC noise problems and a major reason for tenant complaints. ROOFTOP UNITS The most commonly used heating,

More information

Samuel Tepp Engineering Seminar Topics

Samuel Tepp Engineering Seminar Topics Samuel Tepp Associates 11 Leonard Street Metuchen, New Jersey 08840 Contact: Keith Miller, Cell: 201-638-6591, kmiller@samtepp.net Samuel Tepp Engineering Seminar Topics All topics are approved for New

More information

Cannon T4 Modular Data Center (MDC)

Cannon T4 Modular Data Center (MDC) SOLUTIONS Cannon T4 Modular Data Center (MDC) Cannon T4 Modular Data Centers are part of Cannon T4 Data Center Solutions Cannon T4 Data Center Solutions Overview T4 Data Centers T4 Mini Data Centers T4

More information

ECOBAY: Closed loop water cooled server cabinet for data centers

ECOBAY: Closed loop water cooled server cabinet for data centers ECOBAY: Closed loop water cooled server cabinet for data centers ELECTRONICS MANUFACTURING SERVICES Communications Computing Multimedia & Consumer Industrial & Semiconductor Defense & Aerospace Medical

More information

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres Product Brochure DENCO Close Control Units Row-DENCO High Density Cooling for Data Centres Data Centre Cooling Through a history in close control, we have developed a broad and deep understanding of how

More information

Tier IV Standards as Specified in the TIA 942 Document

Tier IV Standards as Specified in the TIA 942 Document S No Architectural Proximity of visitor parking to data 18.3 m / 60 ft minimum separation with physical barriers to prevent vehicles from 1 center perimeter building walls driving closer 2 Building Construction

More information

KINETICS Vibration Isolation Manual

KINETICS Vibration Isolation Manual The Pitfalls of Combining Internal & External Equipment Isolation Introduction: Almost all Make-up Air Units (MAU), Air Handling Units (AHU), and Rooftop Units (RTU) have internal spring-type isolation

More information

Computational Fluid Dynamics at CERN

Computational Fluid Dynamics at CERN Computational Fluid Dynamics at CERN TS/CV/Detector Cooling - CFD Team AT Seminar AT Auditorium July 28, 2005 Michele Battistin, Sara Correia, Moritz Kuhn, Anna Mueller, Antonio Romanazzi, Vaclav Vins,

More information

Temperature/Humidity, Vibration Chambers

Temperature/Humidity, Vibration Chambers Temperature/Humidity, Vibration Chambers CV-Series AV-Series Vibration Chambers Cincinnati Sub-Zero s AV/CV-Series chambers offer rapid temperature change rates to reduce product development time and improve

More information

NetShelter CX Technical Guide

NetShelter CX Technical Guide NetShelter CX Technical Guide A soundproofed Server Room in a Box which allows for IT deployment wherever and whenever it is needed, saving space, cost and deployment time. Model AR4038 & AR4038I >Physical

More information

Prediction of Chilled Water Plant Failures and System Optimization Using Multivariate Modeling Techniques

Prediction of Chilled Water Plant Failures and System Optimization Using Multivariate Modeling Techniques Prediction of Chilled Water Plant Failures and System Optimization Using Multivariate Modeling Techniques Joel Urban Director of Quality Assurance Brady Services, Inc. Leah Lehman IoT Program Director

More information

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II

Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II Building Re-Tuning (BRT) Lesson 4: SOI Air-Handling Unit Part II Lesson 4: Sections Review of last class (0:20) Section 1: AHU: Discharge air temperature control (0:45) Break (0:10) Section 2: AHU: Heating

More information

Measurement of Static Insertion Loss of Flexible Ducting

Measurement of Static Insertion Loss of Flexible Ducting Westaflex Australia Pty. Ltd. Measurement of Static Insertion Loss of Flexible Ducting This Laboratory is accredited by the National Association of Testing Authorities, Australia. The results reported

More information

Acoustic Source Location in Vehicle Cabins and Free-field with Nearfield Acoustical Holography via Acoustic Arrays.

Acoustic Source Location in Vehicle Cabins and Free-field with Nearfield Acoustical Holography via Acoustic Arrays. Acoustic Source Location in Vehicle Cabins and Free-field with Nearfield Acoustical Holography via Acoustic Arrays. D.L.Hallman S.M. Dumbacher B.W. Libbey J.S. Bolton D.L. Brown M.J. Lally Herrick Laboratories

More information

ACTIVE NOISE CONTROL APPLIED TO BUILDINGS COMPONENTS

ACTIVE NOISE CONTROL APPLIED TO BUILDINGS COMPONENTS ACTIVE NOISE CONTROL APPLIED TO BUILDINGS COMPONENTS PACS REFERENCE: 43.50.Ki Scamoni Fabio; Valentini Fabrizio CNR-ITC via Lombardia, 49 20098 S. Giuliano M. MI Italy Tel: +39 2 96210 Fax: +39 2 982088

More information

NetShelter CX Performance Guide

NetShelter CX Performance Guide NetShelter CX Performance Guide The Netshelter CX is a soundproofedd Room in a Box which allows for IT deployment wherever and whenever it is needed, saving space, cost and deployment time. Here is one

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION Analog MEMS Microphone Datasheet SANICO ELECTRONICS CONTENTS 1. General Description... 3 2. Features... 3 3. Application... 3 4. Electrical Characteristics... 4 5. Typical Frequency

More information

Environmental Noise Study of. Findlay Creek Public School Findlay Creek Drive, Ottawa, Ontario. R1. Prepared for: N45 Architecture Inc.

Environmental Noise Study of. Findlay Creek Public School Findlay Creek Drive, Ottawa, Ontario. R1. Prepared for: N45 Architecture Inc. Environmental Noise Study of Findlay Creek Public School 3010 Findlay Creek Drive, Ottawa, Ontario. R1 Prepared for: N45 Architecture Inc. Prepared by: Eric Sladic February 5 th, 2015 Contents 1.0 Introduction...1

More information

Branch Circuit Power Systems Access Floor Modules AFm and AFm/M Series

Branch Circuit Power Systems Access Floor Modules AFm and AFm/M Series Branch Circuit Power Systems Access Floor Modules AFm and AFm/M Series 21 AFm Series Access Floor Modules Technical Specifications The ACS/Uni-Fab AFm series access floor module offers a highly adaptable

More information

Power and Cooling for Ultra-High Density Racks and Blade Servers

Power and Cooling for Ultra-High Density Racks and Blade Servers Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has

More information

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system Fair City Plaza Task: Diagnose problems, recommend improvements for small municipal district cooling system The Fair City Plaza district cooling system provides chilled water to five buildings in a downtown

More information

PRODUCT DATA. PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis. Uses and Features

PRODUCT DATA. PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis. Uses and Features PRODUCT DATA PULSE Indoor Pass-by Noise Testing Type 7793 with Optional Exterior Noise Contribution Analysis Pass-by measurements are mandatory for automotive manufacturers for product certification and

More information

Ultra Micro Cooling Device

Ultra Micro Cooling Device Ultra Micro Cooling Device Blow your mobile phone s heat off! Let your mobile devices be worry-free! Smart Phone Pad Ultrabook Ionic Air Purifier Pico Projector * Customized with thickness under mm cooling

More information

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC Freecooling Scroll Chillers for the Efficient Cooling of Data Centers Liebert HPC: Freecooling Solutions for Increased Data Center Efficiency and PUE of 1.1 Freecooling data center chillers

More information

CenterPoint Energy Retro-Commissioning Program Application

CenterPoint Energy Retro-Commissioning Program Application CenterPoint Energy Retro-Commissioning Program Application CenterPoint Energy Retro-Commissioning Program is offered to Commercial and Industrial customers in our service territory to enhance their facility

More information

oom Pressurization Con

oom Pressurization Con Technical Specification Sheet Rev. 3, December, 1998 Room Pressurization Controllers equipment. This approach to room control includes the following features. Features gure 1. Roo oom Pressurization Con

More information

ORION Smart Vibration Monitoring Terminal. Always keep an eye on vibrations. 01dB.com

ORION Smart Vibration Monitoring Terminal. Always keep an eye on vibrations. 01dB.com Distributed by: Air-Met Scientific Pty Ltd Work with Confidence Air-Met Sales/Service P: 1800 000 744 F: 1800 000 774 E: sales@airmet.com.au ORION Smart Vibration Monitoring Terminal Always keep an eye

More information

COMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012

COMMERCIAL AIR CONDITIONERS Flooded Type Water Cooled Screw Chiller 2012 MCAC-2012-37 COMMERCIAL AIR CONDITIONERS 2012 Commercial Air Conditioner Business Units Midea Air Conditioning and Refrigeration Sector Add: West region of Midea commercial air conditioner department,

More information

Application of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection

Application of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection Application of Modular, Rapidly Deployable CBR Filtration and Environmental Conditioning Systems for Building Collective Protection Carl S. Pates III, Ph.d, P.E., New World Associates John Milligan, P.E.,

More information

FOR SALE 7325 ASPEN LANE

FOR SALE 7325 ASPEN LANE FOR SALE 7325 ASPEN LANE Brooklyn Park, Minnesota MATT OELSCHLAGER Senior Vice President +1 952 924 4848 matt.oelschlager@cbre.com MIKE BOWEN Senior Associate +1 952 924 4885 mike.bowen@cbre.com JOHN RYDEN,CCIM,SIOR

More information

Towards Self-Conscious Buildings through connected products

Towards Self-Conscious Buildings through connected products Building Efficiency If you can read this Click on the icon to choose a picture or Reset the slide. To Reset: Right click on the slide thumbnail and select reset slide or choose the Reset button on the

More information

The 5.8mm diameter ROM-2235L-HD-R is designed for extreme fidelity in a compact housing with true 20 Hz to 20 khz performance.

The 5.8mm diameter ROM-2235L-HD-R is designed for extreme fidelity in a compact housing with true 20 Hz to 20 khz performance. Data Sheet ROM-2235L-HD-R PUI Audio s all-new HD Series microphones use premium-grade FETs and diaphragms for high sensitivity and superior signal-to-noise ratio. Each microphone features GSM buzz-blocking

More information

FOR SALE 7325 ASPEN LANE

FOR SALE 7325 ASPEN LANE FOR SALE 7325 ASPEN LANE Brooklyn Park, Minnesota MATT OELSCHLAGER Senior Vice President +1 952 924 4848 matt.oelschlager@cbre.com MIKE BOWEN Senior Associate +1 952 924 4885 mike.bowen@cbre.com JOHN RYDEN,CCIM,SIOR

More information

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview Contents 1. Document Purpose... 2 2. Facility Overview... 2 2.1 Technical Space... 2 2.2 Load Density... 2 2.3 Resilience... 2 2.4 Engineering Plant Maintenance & Service Restoration... 3 3. Engineering

More information

We have you walking on air

We have you walking on air Building FlexSys TM Underfloor air simplified distribution We have you walking on air If you own or operate a building today, it s critical that you control energy costs, reduce the environmental impact

More information

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America 7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer

More information

IMPACT DOT-MATRIX PRINTER

IMPACT DOT-MATRIX PRINTER 1.Safety Notice: * Don't touch the printer head with anything. * Don't touch the cutter blade. * Don't bend the power cord excessively or place any heavy objects onto it. * Don't use the printer when it

More information

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers Precision Cooling for Business-Critical Continuity Liebert HPC-S Designed for the Efficient Cooling of Small Data Centers Liebert HPC-S: Enhanced Efficiency Freecooling Chiller Higher energy costs, limited

More information

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc Current Data Center Design James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc What is the biggest facility problem in your data center? 35% 30% 25% 20% 15% Series1 10% 5% 0% Excessive heat Insufficient

More information

HVAC Energy Management System

HVAC Energy Management System HVAC Energy Management System Spotlight coordinates the complex tasks required by a building s heating, cooling, fresh air, humidification and lighting systems resulting in increased efficiencies. OVERVIEW

More information

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176 B 0 LD- F 9. φ D H H a 8.5 5 5 A E 7 LD- F 8 8.5 9. 5 5 A 7 E LD-/ LD-/ LD- O/ LD- O/ LD- O/ LD- O/.5.5.5.5 LD-/ LD-/ LD-/ LD-/ LD-/ LD-/ 7.5 7.5 07 LD- O/ LD- O/ LD- O/ LD- O/ 5.5 5.5 5.5 5.5 9.5 87.5

More information

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC ::

Course Description. Audience. Prerequisites. : Course CTDC : Certified TIA-942 Design Consultant. Course Outline :: CTDC :: Module Title Duration : Course CTDC : Certified TIA-942 Design Consultant : 3 days Course Description Data centres are at the core of many organisations. Downtime of the data centre could lead to major

More information

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions NREL Validates LCS Technology PRESENTED BY Herb Zien CEO, LiquidCool Solutions Learning Objectives As much as 40% of data center power is used to circulate air, and fans in a typical 30-megawatt data center

More information

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management Name Doug Demian Title Application Engineer Date November 7 & 8, 2012 Rev 5058-CO900C Copyright 2012 Rockwell

More information

Electronics Cooling Using Conduction Convection Radiation from Heat Sinks to Heat Pipes - CFD Consulting Services

Electronics Cooling Using Conduction Convection Radiation from Heat Sinks to Heat Pipes - CFD Consulting Services Electronics Cooling Using Conduction Convection Radiation from Heat Sinks to Heat Pipes - CFD Consulting Services Predictive Engineering s CFD Consulting Experience Electronics cooling can be as simple

More information

Buildings of the Future. Dave Hopping President, Siemens Building Technologies - Americas

Buildings of the Future. Dave Hopping President, Siemens Building Technologies - Americas Buildings of the Future Dave Hopping President, Siemens Building Technologies - Americas June 23, 2017 Buildings of the Future Introduction Siemens - Building Technologies Trends in our Industry Smart

More information

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com End-to-End Cooling Solutions from the Closet to the Data

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Facility Requirements LaserCube SYS-4x4-YLS

Facility Requirements LaserCube SYS-4x4-YLS Introduction Facility Requirements LaserCube SYS-4x4-YLS Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

More information

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY. INNOVATE DESIGN APPLY By A whole new cooling experience The Motivair ChilledDoor Rack Cooling System targets the critical cooling requirements of today s modern server rack designs. As technology continues

More information

Final Thesis Presentation

Final Thesis Presentation Final Thesis Presentation Spring 2011 Advisor: Dr. Treado Building Overview Existing Conditions System Evaluation Building Overview Existing Conditions System Evaluation Building Overview Existing Conditions

More information

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM 1. Category (Check one and indicate New or Existing, if applicable) Commercial Buildings New or Existing Institutional Buildings: Educational Facilities New

More information

Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building

Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building Intelligent / Sustainable Buildings utilizing Under-Floor HVAC Systems Advantages over the Life Cycle of a Commercial Building We shape our buildings and then our buildings shape us Winston Churchill,

More information

Driving Proactive Facility Operations with Automated HVAC Diagnostics

Driving Proactive Facility Operations with Automated HVAC Diagnostics Driving Proactive Facility Operations with Automated HVAC Diagnostics Turn HVAC Data into Actionable Information AKA Monitoring Based Commissioning Ongoing Commissioning Automated Fault Detection & Diagnostics

More information

84 kw, Tier 3, Direct Expansion, 937 ft 2

84 kw, Tier 3, Direct Expansion, 937 ft 2 [Reference Design 42] 84 kw, Tier 3, Direct Expansion, 937 ft 2 DESIGN OVERVIEW Data Center IT Capacity 84 kw Target Availability Tier 3 Annualized PUE at 100% Load 1.712 Total Racks and Average Density

More information

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications

TECHNICAL DATA SHEET. FreeSpace DS 100SE. Loudspeaker. Product Overview. Key Features. Product Information. Applications Product Overview The Bose FreeSpace DS 100SE loudspeaker is a high-performance, surface-mount loudspeaker designed for foreground music and speech reproduction in a wide range of commercial applications,

More information

Room acoustic modelling of a reverberation chamber

Room acoustic modelling of a reverberation chamber Room acoustic modelling of a reverberation chamber Konca SAHER 1 ; Sezin NAS 2 ; Baki KARABÖCE 3 ; Cafer KIRBAŞ 4 ; Eyüp BİLGİÇ 5 1 Kadir Has University, Interior Architecture and Environmental Design,

More information

ComEd Retro-Commissioning and Monitoring-Based Commissioning

ComEd Retro-Commissioning and Monitoring-Based Commissioning ComEd Retro-Commissioning and Monitoring-Based Commissioning Rick Tonielli Sr. Program Manager C O N F I D E N T I A L Territory profile ComEd is an electric delivery company providing service to 3.8 million

More information

User s Guide. Recair Smart Air Designer MagiCAD Plugin - Installation Instructions and User Guide

User s Guide. Recair Smart Air Designer MagiCAD Plugin - Installation Instructions and User Guide User s Guide Recair Smart Air Designer MagiCAD Plugin - Installation Instructions and User Guide Contents About this document... 2 Installing the software... 3 Required third-party software... 3 Installation...

More information

This document is downloaded from the Digital Open Access Repository of VTT. VTT P.O. box 1000 FI VTT Finland

This document is downloaded from the Digital Open Access Repository of VTT. VTT  P.O. box 1000 FI VTT Finland This document is downloaded from the Digital Open Access Repository of VTT Title NOVI - Advanced functional solutions for Noise and Vibration reduction of machinery, Deliverable D2.5 & D2.8 Modelling tools

More information

Building Energy Management Training Systems

Building Energy Management Training Systems Building Energy Management Training Systems 3466-00 LabVolt Series Datasheet Festo Didactic en 120 V - 60 Hz 03/2019 Table of Contents General Description 2 Courseware 2 Topic Coverage 2 List of Available

More information

SISTINE CHAPEL STUDY & PROJECT. NAME Title Carrier HVAC Europe

SISTINE CHAPEL STUDY & PROJECT. NAME Title Carrier HVAC Europe SISTINE CHAPEL STUDY & PROJECT NAME Title Carrier HVAC Europe THE CHALLENGE CONTEXT 1993 700 visitors simultaneously XXX 2010 Xxxxxx Up to 2,000 visitors simultaneously 1 st air-conditioning system designed

More information

The Shared Data Centre Project

The Shared Data Centre Project David Birds - Data Centre Manager Oxford University Computing Services Networkshop 39 13 th April 2011 Why do we need it? 1. Additional data centre capacity. 2. The opportunity to provide a higher level

More information

5.2 MW, Pod-based build, Chilled Water, ft 2

5.2 MW, Pod-based build, Chilled Water, ft 2 [Reference Design 65] 5.2 MW, Pod-based build, hilled Water, 85000 ft 2 DESIGN OVERVIEW Data enter apacity 5.2 MW Target Availability Tier III with 2N power distribution and less-redundant generator configuration

More information

Thermal Diffusivity Instruments DLF-2 with EM-1600

Thermal Diffusivity Instruments DLF-2 with EM-1600 Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...

More information

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT DYNACIAT: HIGH PERFORMANCE HEATING AND COOLING FOR MEDIUM-SIZED BUILDINGS To better meet customer needs and answer environmental

More information

As a key supplier of EMC testing for the F-22 Program, D.L.S. Electronic Systems, Inc.

As a key supplier of EMC testing for the F-22 Program, D.L.S. Electronic Systems, Inc. As a key supplier of EMC testing for the F-22 Program, D.L.S. Electronic Systems, Inc. Photo courtesy of Lockheed Martin is also capable of meeting your Mil-Std & Commercial Avionics testing needs, whether

More information

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS

DUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS 1 25 95 00 Integrated Automation Control Sequences for HVAC GENERAL The HVAC operational sequences in this guideline are commonly used by Duke University. They are being provided as a preferred design

More information

Energy Performance Contracting

Energy Performance Contracting Energy Performance Contracting December 2017 Outlines Section One: Jonson Controls as an Energy Service Company (ESCO) Reasons behind investment in Energy Efficiency Section Two: Funding Options of Energy

More information

Dual Duct Controller - One Air Velocity

Dual Duct Controller - One Air Velocity Technical Specification Sheet Rev. 4, December, 1998 Dual Duct Controller - One Air Velocity Sensor gure 1. Dual Duct Con ontr troll ller One Air Velocity Sen ensor. The Dual Duct Controller (re 1) is

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

Media Pack. ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING

Media Pack.  ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING Media Pack www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING 02 About Airedale Providing integrated thermal management solutions Differentiated through innovation and service

More information

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length

diffusers F24 PERFORMANCE DATA PERFORMANCE DATA ML-37 / ½ SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM Throw correction multiplier for length ML-37 / ½" SLOT SPACING WIDTH / SUPPLY WITH CONTINUOUS PLENUM 5-Slot 6-Slot 7-Slot 8-Slot Airflow, cfm/ft. 5 10 16 21 26 31 36 42 47 NC (Noise Criteria) - - 20 27 32 37 40 44 46 Horizontal 1-1-6 3-6-12

More information

Engineering Services

Engineering Services Engineering Services Improving Product Sound Quality In today s competitive environment, product refinement must not only consider the level of noise a product emits but also the quality of the sound it

More information

Why Should We Care? Building Intelligent Solutions 2

Why Should We Care? Building Intelligent Solutions 2 Why Should We Care? Building Intelligent Solutions 2 Responsible environmental leadership Building Intelligent Solutions 3 Responsible environmental leadership Setting targets for reducing energy consumption

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

Chloride CROSS Rack 16 A, 32 A and 63 A

Chloride CROSS Rack 16 A, 32 A and 63 A AC Power for Business-Critical Continuity Chloride CROSS Rack 16 A, 32 A and 63 A STS Catalogue Chloride CROSS Rack High Voltage and Low Voltage 2 Pole Complete Reliability On-line Static Switch 16 A,

More information

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management Slide-1 LANL High Performance Computing Facilities Operations Rick Rivera and Farhad Banisadr Facility Data Center Management Division Slide-2 Outline Overview - LANL Computer Data Centers Power and Cooling

More information

Pathfinder AWV air-cooled screw chillers

Pathfinder AWV air-cooled screw chillers Pathfinder AWV air-cooled screw chillers Three industry firsts» 100% configurable chiller» Variable Volume Ratio compressor technology» First air-cooled screw chiller with IPLVs exceeding 22 165 to 550

More information