N IO T C N U F S M S EN ENGLISH LB EDITION JULY 2011
|
|
- Candice Doyle
- 6 years ago
- Views:
Transcription
1 SMS FUNCTION EN ENGLISH LB EDITION JULY 2011
2 GENERAL FEATURES See below the list of general performance of the GSM option connected to the coffee machine. 1) GSM mounted on the machine sends SMS with DOSE INFORMATION: - no. of dispensed doses (only of the total B) - total no. of cleaning cycles (group and milker and mixer if present) - GSM to be connected to master-pcb CN16 2) GSM mounted on the machine sends SMS with MACHINE STATUS INFORMATION: - machine state: ON, OFF, warm-up, busy. - boilers temperature - grinder cycles set-up - water filter litres set-up - service group cycle set-up - total machine cycle - 3) GSM mounted on the machine sends SMS with VEND DATA AUDIT INFORAMTION: - no. of dispensed doses and the relevant date and time - 4) Mobile phone can sends SMS to the GSM mounted on the machine asking for DOSE INFORMATION: See page 6 for more information 5) GSM mounted on the machine sends SMS whenever an alarm blocks the machine ALARM DETAILS ALARM CODE NO H. MOTOR PULS 10 NO L. MOTOR PULS 11 H. MOTOR ERROR 12 L. MOTOR ERROR 13 FILLING UP T.O. 32 COFFEE HEAT T.O. 33 STEAM HEAT T.O. 34 CHECK FLOW LINE 35 COFFEE TEMPERATURE 37 STEAM TEMPERATURE 38 INFUSION T.O. 41 FRIDGE TEMP. PROBE 45 FRIDGE TEMPERATURE 46 CORRUPTED DATA 60 CLOCK ERROR 63 MOTOR BLOCK 65 TRASPONDER PCB 66 FRIDGE SERIAL 67 COIN VALIDATOR ERROR 70 CHANGE H2O FILTER 90 GROUP MAINTENA 91 GRINDER MAINTENA 93 TOO MUCH COFFEE 15 MAINTENANCE 92 Please Note: Messages are automatically sent at the programmed time and frequency, which can be programmed on the machine in SYSTEM MANAGER SERVICE SMS SERVICE menu. In case the machine has been powered OFF for a period of time, at the following power ON, the machine will send one message with the missing information. LB EN Pag. 2 28/07/11
3 ACCESS THE MAIN SETTING MENU OF THE COFFEE MACHINE Follow the instruction below to enter the main menu and enable all parameters related to the GSM To enter the programming environments, the TECHNICIAN password is required (contact the I.MC. Technical Service). To insert the passwords proceed as follows: - Turn the machine OFF - Keep N 12 SHIFT key pressed for 5 seconds. The display shows: KEY REFERENCE MX-5-GOLD-PLATINUM ARMONIA-TOUCH OPTIMA PASSWORD esc After having inserted the password, the display shows the main menu programming environments: Press key no. 5 (-) and No 6 (+) to select the parameter Press key no. 7 (Enter) to confirm Press key no. 8 (Esc) to quit. LB EN Pag. 3 28/07/11
4 Enter in SYSTEM MANAGER MACHINE CONFIGURATION menu and program the following program the following parameters: Enter in SYSTEM MANAGER MACHINE PARAMETERS menu and program the following parameters: Enter in SYSTEM MANAGER SYSTEM CLOCK PROGRAMMING menu and program the following program the following parameters: LB EN Pag. 4 28/07/11
5 Enter in SYSTEM MANAGER SERVICE SMS SERVICE menu and program the following parameters: LB EN Pag. 5 28/07/11
6 SEND SMS TO THE GSM OF THE MACHINE The SMS messages sent to the machine with the request for information must be typed with only either upper-case or lower-case letters; moreover, the messages must be preceded by the remote password inserted in System Manager Machine Parameters Service SMS Service menu (remote password 12345). If the command is not recognised or the password is wrong, you will receive the following message: SMS command fail B1) COMMAND TO REQUEST THE STATE OF THE MACHINE: Example: 12345STATUS The machine replies with message having the following information: - machine serial number - machine name - software release - machine state: ON, OFF, warm-up, busy, ready - steam boiler level - waste level - coffee boiler temperature - steam boiler temperature - current date and time (yy-mm-dd-hh-mm) In case of alarm the machine sends a second message with the relevant information: i.e. Current alarm H MOTOR ERROR 12 B2) COMMAND TO REQUEST TO SWITCH ON THE MACHINE: Example: 12345ON B3) COMMAND TO REQUEST TO SWITCH OFF THE MACHINE: Example: 12345OFF B4) COMMAND TO REQUEST TOTAL DOSE COUNT "A OR B : Example-1: 12345TOTALA Example-2: 12345TOTALB The machine replies with three messages: First message with the counts for all 10 keys, standard and shift doses (total 20 records) Second message with the counts for all 10 keys, decaffeinated doses (total 20 records) Third message with the counts for extramilk and total cashing (total 2 records) B5) COMMAND TO REQUEST OF TOTAL COUNTS OF SERVICE DATA: Example: 12345SERVICEDATA The machine replies one message with the following information: counts of group cleaning cycles, mixer cleaning cycles, milker cleaning cycles, grinder 1 and 2 cycles, water filter liters, partial and total group cycles. B6) COMMAND TO SEND A MESSAGE ON THE MACHINE DISPLAY: Example: 12345MSG: HELLO It is possible to send a message with maximum 26 characters that will be visualized on the display for approximately 50 seconds. B7) COMMAND TO REQUEST ALARM HISTORY: Example: 12345ALARM The machine replies with up to three messages with all the alarms in System Manager Alarm history menu. Each message can report up to three alarms. LB EN Pag. 6 28/07/11
7 SMS DOSES INFORMATION REGULAR DOSES OPTIMA ARMONIA-TOUCH MX-5-PLATINUM/GOLD MAX. FIELD MINIMUM FIELD TOTAL WITH MAX CONFIGURATION FIELD DESCRIPTION Type of SMS (D stands for DOSES) D Progressive SMS record number Total SMS record number Field separator 1 1 4, Serial number (10 digits alfanumeric) Field separator , Machine model (2 digits alfanumeric) Field separator , Current date (YYMMDD) Current time (hhmm) Field separator , Button 1 counter Field separator , Button 2 counter Field separator , Button 3 counter Field separator , Button 4 counter Field separator , Button 5 counter Field separator , Button 6 counter Field separator , Button 7 counter Field separator , Button 8 counter Field separator , Button 9 counter Field separator , Button 10 counter Field separator , See following page VALUE LB EN Pag. 7 28/07/11
8 Button 1-Shift counter Field separator , Button 2-Shift counter Field separator , Button 3-Shift counter Field separator , Button 4-Shift counter Field separator , Button 5-Shift counter Field separator , Button 6-Shift counter Field separator , Button 7-Shift counter Field separator , Button 8-Shift counter Field separator , Button 9-Shift counter Field separator , Button 10-Shift counter Field separator , Extramilk counter Field separator , Total token A counter Field separator , Total token B counter Field separator , Total token C counter Field separator , Total cashing Field separator , Group cleaning cycles counter Field separator , Mixer cleaning cycles counter Field separator , Milker cleaning cycles counter Field separator , Power cleaning cycles counter Field separator , Example: D11,CA ,LM, ,100,50,119,123,9,234,29,30,25,22,,,,,,,,,,,120,,,,0.0,20,20,20, Please Note: a) Mixer, Milker and Power cleaning cycles are not visualized if not programmed (present) in the machine; therefore the total length of the message will be shorter b) For those buttons programmed as DISABLED, the counter will not zero (0) but empty; for instance:,,,,, LB EN Pag. 8 28/07/11
9 SMS DOSES INFORMATION DECAFFEINATED DOSES OPTIMA ARMONIA-TOUCH MX-5-PLATINUM/GOLD MAX. FIELD MINIMUM FIELD TOTAL WITH MAX CONFIGURATION VALUE FIELD DESCRIPTION Type of SMS (K stands for DECAFFEINATED DOSES) K Field separator 1 1 2, Serial number (10 digits alfanumeric) Field separator , Machine model (2 digits alfanumeric) Field separator , Current date (YYMMDD) Current time (hhmm) Field separator , Button 1 counter Field separator , Button 2 counter Field separator , Button 3 counter Field separator , Button 4 counter Field separator , Button 5 counter Field separator , Button 6 counter Field separator , Button 7 counter Field separator , Button 8 counter Field separator , Button 9 counter Field separator , Button 10 counter Field separator , Button 1-SHIFT counter Field separator , Button 2-SHIFT counter Field separator , Button 3-SHIFT counter Field separator , Button 4-SHIFT counter Field separator , Button 5-SHIFT counter Field separator , Button 6-SHIFT counter Field separator , Button 7-SHIFT counter Field separator , Button 8-SHIFT counter Field separator , Button 9-SHIFT counter Field separator , Button 10-SHIFT counter Field separator , Example: K,CA ,LM, ,100,50,119,123,0,0,0,0,,,0,0,0,0,0,0,0,0,,, Please Note: For those buttons programmed as DISABLED, the counter will not zero (0) but empty; for instance:,,,,, LB EN Pag. 9 28/07/11
10 SMS DOSES INFORMATION REGULAR DOSES ARMONIA OPTIMA-SILVER MX-3 MX-5-SILVER FOR ARMONIA OPTIMA-SILVER MX-3 MX-5-SILVER MINIMUM MAX. FIELD FIELD TOTAL WITH MAX CONFIGURATION FIELD DESCRIPTION Type of SMS (D stands for DOSES) D Progressive SMS record number Total SMS record number Field separator 1 1 4, Serial number (10 digits alfanumeric) Field separator , Machine model (2 digits alfanumeric) Field separator , Current date (YYMMDD) Current time (hhmm) Field separator , Button 1 counter Field separator , Button 2 counter Field separator , Button 3 counter Field separator , Button 4 counter Field separator , Button 5 counter Field separator , Button 6 counter Field separator , Button 7 counter Field separator , Button 8 counter Field separator , Button 1-Shift-1 counter Field separator , Button 2-Shift-1 counter Field separator , Button 3-Shift-1 counter Field separator , Button 4-Shift-1 counter Field separator , Button 5-Shift-1 counter Field separator , Button 6-Shift-1 counter Field separator , Button 7-Shift-1 counter Field separator , Button 8-Shift-1 counter Field separator , See following page VALUE LB EN Pag /07/11
11 Button 1-Shift-2 counter Field separator , Button 2-Shift-2 counter Field separator , Button 3-Shift-2 counter Field separator , Button 4-Shift-2 counter Field separator , Button 5-Shift-2 counter Field separator , Button 6-Shift-2 counter Field separator , Button 7-Shift-2 counter Field separator , Button 8-Shift-2 counter Field separator , Extramilk counter Field separator , Total token A counter Field separator , Total token B counter Field separator , Total token C counter Field separator , Total cashing Field separator , Group cleaning cycles counter Field separator , Mixer cleaning cycles counter Field separator , Milker cleaning cycles counter Field separator , Power cleaning cycles counter Field separator , Example: D11,CA ,LM, ,100,50,119,123,9,234,29,30,,,,,,,,,,,,,,,,,120,,,,0.0,20,20,20,20, Please Note: a) Mixer, Milker and Power cleaning cycles are not visualized if not programmed (present) in the machine; therefore the total length of the message will be shorter b) For those buttons programmed as DISABLED, the counter will not zero (0) but empty; for instance:,,,,, LB EN Pag /07/11
12 SMS DOSES INFORMATION DECAFFEINATED DOSES ARMONIA OPTIMA-SILVER MX-3 MX-5-SILVER MAX. FIELD MINIMUM FIELD TOTAL WITH MAX CONFIGURATION VALUE FIELD DESCRIPTION Type of SMS (K stands for DECAFFEINATED DOSES) K Field separator 1 1 2, Serial number (10 digits alfanumeric) Field separator , Machine model (2 digits alfanumeric) Field separator , Current date (YYMMDD) Current time (hhmm) Field separator , Button 1 counter Field separator , Button 2 counter Field separator , Button 3 counter Field separator , Button 4 counter Field separator , Button 5 counter Field separator , Button 6 counter Field separator , Button 7 counter Field separator , Button 8 counter Field separator , Button 1-SHIFT-1 counter Field separator , Button 2-SHIFT-1 counter Field separator , Button 3-SHIFT-1 counter Field separator , Button 4-SHIFT-1 counter Field separator , Button 5-SHIFT-1 counter Field separator , Button 6-SHIFT-1 counter Field separator , Button 7-SHIFT-1 counter Field separator , Button 8-SHIFT-1 counter Field separator , Button 1-SHIFT-2 counter Field separator , Button 2-SHIFT-2 counter Field separator , Button 3-SHIFT-2 counter Field separator , Button 4-SHIFT-2 counter Field separator , Button 5-SHIFT-2 counter Field separator , Button 6-SHIFT-2 counter Field separator , Button 7-SHIFT-2 counter Field separator , Button 8-SHIFT-2 counter Field separator , Example: K,CA ,LM, ,100,50,119,123,0,0,,,20,22,0,0,0,0,,,43,33,0,0,0,0,,, Please Note: For those buttons programmed as DISABLED, the counter will not zero (0) but empty; for instance:,,,,, LB EN Pag /07/11
13 SMS MACHINE STATUS INFORMATION ALL MACHINE MODEL MAX. FIELD MINIMUM FIELD TOTAL WITH MAX CONFIGURATION FIELD DESCRIPTION VALUE Type of SMS (S stands for SERVICE) S Field separator 1 1 2, Serial number (10 digits alfanumeric) Field separator , Machine model (2 digits alfanumeric) Field separator , Current date (YYMMDD) Current time (hhmm) Field separator , Software version Field separator , Machine status =Off 1=Warm up 2=Ready 3=Busy Field separator , Boiler level =Low 1=Ok Field separator , Waste level =Low 1=Ok Field separator , Coffe temperature Field separator , Steam temperature Field separator , Fridge-Plus internal emperature Field separator , Grinder cycles set-up Field separator , Grinder cycles Field separator , Grinder cycles Field separator , Water filter litres set-up Field separator , Water filter maintenance date set-up (yymmdd) Field separator , Water filter litre counter Field separator , Service group cycle set-up Field separator , Maintenance date set-up (yymmdd) Field separator , Service group cycle counter Field separator , Total group cycle Field separator , Total machine cycle Field separator , Example: SCA ,Rev.2.02h,2,1,1,90,124,4,15000,12000,6500,2000,081207,1400,10000,080607,1200,50234,100234, LB EN Pag /07/11
14 SMS VENDS MESSAGE OPTIMA ARMONIA-TOUCH MX-5-PLATINUM/GOLD MAX. FIELD MIN. FIELD TOTAL WITH MAXIMUM CONFIGURATION VALUE FIELD DESCRIPTION EXAMPLE Type of SMS (V stands for VENDS) V V Field separator 1 1 2,, Serial number (alfanumeric) CA Field separator ,, Machine model LM Field separator ,, Date for which data is recorded (yymmdd) Field separator ,, Data 1 : unique vend reference Data 1 : drink type Data 1 : vend time (hhmm) Field separator ,, Data 2 : unique vend reference Data 2 : drink type Data 2 : vend time (hhmm) Field separator ,, Data 3 : unique vend reference Data 3 : drink type Data 3 : vend time (hhmm) Field separator ,, Data 4 : unique vend reference Data 4 : drink type Data 4 : vend time (hhmm) Field separator ,, Data 5 : unique vend reference Data 5 : drink type Data 5 : vend time (hhmm) Field separator ,, Data 6 : unique vend reference Data 6 : drink type Data 6 : vend time (hhmm) Field separator ,, Data 7 : unique vend reference Data 7 : drink type Data 7 : vend time (hhmm) Field separator ,, Data 8 : unique vend reference Data 8 : drink type Data 8: vend time (hhmm) Field separator ,, Data 9 : unique vend reference Data 9 : drink type Data 9 : vend time (hhmm) Field separator ,, See following page LB EN Pag /07/11
15 Data 10 : unique vend reference Data 10 : drink type Data 10 : vend time (hhmm) Field separator ,, Example: V,CA ,LM,110518, , , , , , , , , , , Please Note: The vends data are saved in a circular buffer file that can save up to 700 drink vends. When the file is full, 700 selections saved, the data storage restarts from the file, beginning overwriting the first record. The vend identifier starts from 0 and increases by 1 for each saved drink vend. When the counter reaches 65535, it restarts automatically from 0. Vends data will be sent automatically each day at the setup time. The vends data refer to the vends of the day before. If the telemetry reaches 100 daily vends, it will send data before the set up time. When the set up time elapses, the remaining data are sent. The vends data transmission can be set only daily, neither weekly nor monthly. By sending a SMS message to the machine, it is possible to ask the transmission of the vends data of a specific day, only if the data are still available in the file. By GSM Off alarm, the vends data are saved in the file in any case. When the machine is in OFF state, the vends data are sent at the set up time. If no drinks are dispensed for one day or more, the vends data will not be sent. When the machine is powered on, the data are sent if the set up time has elapsed. In system manager menu the following functions are available: - Full audit trail of vends data procedure enabled; - Set up of sending time; - Vends data file reset; - Procedure to read and to modify the vend identifier. LB EN Pag /07/11
16 SMS ALARM MESSAGE ALL MACHINE MODEL MAX. FIELD MIN. FIELD TOTAL MAX CONFIGURATION FIELD DESCRIPTION Type of SMS (A stands for ALARM) A Field separator 1 1 2, Serial number (10 digits alfanumeric) Field separator , Machine name (2 digits alfanumeric) Field separator , Current date (yymmdd) Current time (hhmm) Field separator , Alarm message (in English) Field separator , Alarm code Field separator , VALUE Example: A,CA ,LM, ,H MOTOR ERROR,12, LB EN Pag /07/11
17 The I.M.C. product you have purchased is subject to Directive 2002/96/EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment (WEEE) and, in jurisdictions adopting that Directive, is marked as being put on the market after August 13, 2005, and should not be disposed of as unsorted municipal waste. For further information please contact I.M.C. The manufacturer reserves the right to change, without prior notice, the specifications of the equipment illustrated in this publication; the manufacturer declines all responsibility for any mistakes due to printing and/or typing errors contained in this publication. All instructions, drawings, tables and information contained in this publication are reserved and may not be reproduced entirely or in part or be communicated to a third party without written authorisation from the manufacturer who holds exclusive REVISION TABLE CODE DATE NOTES REVIEWER LB Riccardo Rossi LB Giuliano Viola EDITION JULY 2011 The Manager Maurizio Boffelli Firma del Responsabile della Documentazione LB EN Pag /07/11
Electronic Dosing Systems Ltd
Electronic Dosing Systems Ltd Telephone 01299 825 656 Email info@electronicdosingsystems.co.uk Cooling Tower Systems Touch Series Controllers TOUCH series multifunction parameter systems with touch screen
More informationEASI MP-X Series. User Manual EASI MPR. Workstation. MPR Workstation user manual, , rev003
EASI MP-X Series User Manual EASI MPR Workstation MPR Workstation user manual, 59300234, rev003 Contents MPR Workstation Introduction...1 General...1 Software version...1 Structure of the Network...1 Workstation
More informationADJUSTMENTS & OPTIONAL SETTINGS (CONT.)
ENABLE ADS? DONE NEW AD? TE: The available characters are: A through Z 0 through 9! " # $ % & ' ( ) * +, -. / : ; < = >? @ 2 LINES 16 CHARS AVAILABLE SCROL THRU ALPHA NEXT NEXT LETTER WRITE TOP LINE? WRITE
More informationA1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1
A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for
More informationDexter Washer Programing. Part # 8533-***-*** 03/14
Dexter Washer Programing 3 PROGRAMMING INSTRUCTIONS: The washer control can be programmed to prompt the user for alternate vend prices, change washer cycle times, temperatures and many other options. This
More informationekey home OPERATING INSTRUCTIONS
ekey home en OPERATING INSTRUCTIONS English Translation of the original instructions - ID2245170369 Table of contents General... 2 Note... 2 Product liability and limitation of liability... 2 Warranty
More informationInstruction manual of the controller unit. PCS ph-redox-chlorine-temp PCS ph-oxygen-temp PCS ph-redox-temp
Instruction manual of the controller unit PCS ph-redox-chlorine-temp PCS ph-oxygen-temp PCS ph-redox-temp SPIS TREŚCI GENERAL INFORMATIONS... 3 Main Functions... 3 Unit Specification... 3 Unit Dimensions......
More informationTEI0005 TRM Revision: v.13 Exported on: 02/02/2018
TEI0005 TRM Revision: v.13 Exported on: 02/02/2018 1 Table of Contents 1 Table of Contents... 2 2 Overview... 3 2.1 Key Features... 3 2.2 Block Diagram... 3 3 Signals, Interfaces and Pins... 4 3.1 Module
More informationPOCKET GUIDE ROUTINE MAINTENANCE, SAFETY, INSTALLATION & TROUBLESHOOTING
The 350 REFERENCE SERIES MULTI-PRICE TOTALISER POCKET GUIDE ROUTINE MAINTENANCE, SAFETY, INSTALLATION & TROUBLESHOOTING CashFlow CashFlow CashFlow C ashflow CashFlow CashFlow Cas hflow CashFlow CashFlow
More informationLDCL DIGITAL CONTROLLER OPERATING MANUAL
This manual contains important safety informations about installation and use of this equipment. Ignoring this informations could result in injuries or damages. It is strictly forbidden to use this equipment
More informationAudio GSM module for modular plate
Audio GSM module for modular plate FB00758-EN PROGRAMMING MANUAL MTMA/GSM A General precautions Read the instructions carefully before beginning the installation and carry out the actions as specified
More informationLCD LCDS LCDRI CONTROLLER OPERATING MANUAL
This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment
More informationStatement of compliance no 40/2011
-1- ST-65 module GSM v1.0.7 Statement of compliance no 40/2011 We, the company TECH, headquartered in Wieprz 1047A, 34122 Wieprz, declare with full liability, that the controller ST 65 GSM, produced by
More informationGSM ProTherm PT1000. User Guide
GSM ProTherm PT1000 User Guide INTELEC SYSTEMS Intelligent Electronic Systems 2007-2011 Web: www.intelec-systems.com Copyright Copyright cc, South Africa November 2007, February 2008, June 2008 Revision
More informationManual. LC-16 system. LC-16 Inkjet Printer 1
Manual LC-16 system LC-16 Inkjet Printer 1 Index ENVIRONMENT. 3 OPERATOR S SAFETY 3 OPERATION SAFETY 3 PART 1 INSTALLATION AND PARAMETER SETTING 4 1) Preparing 4 2) Installation 4 3) Priming 4 4) Parameter
More informationPhase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual
Phase 8.3 and 8.4 Rev 2.2 and Rev 2.3 Microprocessor User s Manual Retain This Manual In A Safe Place For Future Reference IMPORTANT NOTE TO PURCHASER Table of Contents General User Information Coin/Debit
More informationHome center SMS integration
Home center 2.7.3+ SMS integration The SMS functionality is available exclusively on the Home center interface Server (VMBHIS or HIS) More info http://www.homecenter.be Revision 02-08-2015 Home center
More information3000 CONTROLLER TRAINING MANUAL. April 26, 2012 Software Version
3000 CONTROLLER TRAINING MANUAL April 26, 2012 Software Version 1.59.03 Contents 3000 CONTROLLER USER GUIDE Quick Reference: Using the 3000... 3 Menu Summary Tree... 6 Main Menu: Programming your Fryer...
More informationLM-100 LM-120 Light Meters Users Manual
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to Amprobe LM100 Digital Lightmeters LM-100 LM-120 Light Meters Users Manual
More informationA1000 GSM ALARM DEVICE
A1000 GSM ALARM DEVICE USER MANUAL A1000-REV2.1-1604 FW-A1000v2.93 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for installation,
More informationRecorders for all applications
Recorders for all applications Within the COMMANDER family are specifically-designed control solution variants for industries such as water and waste water, food, chemical & pharmaceutical and heat treatment.
More informationProducts no longer available
Technical data sheet BKS24-.. MONICO-Controller BKS24-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Controller with application software for control and monitoring
More information19-inch LCD Display Unit User Manual
19-inch LCD Display Unit User Manual M6MM0M1806W003 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact us. This manual is applicable to HDLED18.5
More informationUSER MANUAL Mobeye CM-Guard CM2000
USER MANUAL Mobeye CM-Guard CM2000 SW version 3.n Attention! Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual.
More informationJOVISION. Home Security IP Camera. Quick Start Guide
JOVISION Home Security IP Camera Quick Start Guide Statement Thank you for choosing Jovision, this user manual is intended for users of HD Wireless IP Camera. It includes instructions on how to use the
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationORION BEAN DOSER OPERATION MANUAL
ORION BEAN DOSER OPERATION MANUAL Contents Chapter 1: Introduction Chapter 2: Getting Started Chapter 3: s Chapter 4: Settings Chapter 5: Calibration 1 Chapter 1: Introduction Orion Bean Doser is a professional
More informationGSM communicator GD-06 Allegro Complete manual
GSM communicator GD-06 Allegro Complete manual The GD-06 ALLEGRO is a universal GSM dialer and controller. It can be used for both home and industrial automation purposes, for security applications or
More informationEY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks
EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks How energy efficiency is improved Monitor the operation of your building and recognise optimisation potential, wherever you are Features
More informationProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4
informacije in naročila: info@gsm-komunikatorji.com.gsm-komunikatorji.com ProCon GSM INSTALLATION AND APPLICATION MANUAL for module version 1.4 1 Index I. Basic descriptions... 3 II. Steps of installation...
More informationCommander circular chart recorders The tried and tested solution for process recording
The tried and tested solution for process recording ABB s Commander circular chart recorders provide a tried and tested solution for a host of industries such as water and waste water, food, chemical and
More informationOverview... 1 Accessing the Clean-Up System... 1 Understanding the Layout of the Login Attempts Tab... 2
Clean-Up System Overview... 1 Accessing the Clean-Up System... 1 Understanding the Layout of the Login Attempts Tab... 2 Loading Files into the Login Attempts Tab... 3 Cleaning Login Attempts Files...
More informationED-T7. External touch display, 7 inch. Function. Installation The display can be mounted, for example, on the operation panel of the control cabinet.
hto Revision 2017-11-01 External touch display, 7 inch is a touch screen display and configuration unit intended for connection to a controller. The display offers full control of controllers that are,
More informationUser Manual Revision 1.02
User Manual Revision 1.02 Manufactured by Contents 1. Introduction... 4 2. Disclaimer and Warranty... 4 3. Specifications... 5 4. Features... 5 5. Quick Start Guide... 6 5.1 Hardware... 6 5.2 Software...
More information3 int'l H REGISTER ERRORS AND TROUBLESHOOTING
3 int'l H REGISTER ERRORS AND TROUBLESHOOTING Publication issued by: Olivetti S.p.A. Telecom Italia Group Via Jervis, 77-10015 Ivrea (TO) Copyright 2012, by Olivetti All rights reserved This manual describes
More informationMICROPROCESSOR BATCH CONTROLLER MOD.DOSAX
MICROPROCESSOR BATCH CONTROLLER MOD.DOSAX 2020-2030-2040 THE APPLIANCE DESCRIBED HEREIN CONFORMS TO STANDARDS EN55011, EN61000-3-2, IEC 1000-4-2, IEC1000-4-4 24/01/2006 VERSION 3.0 1 OPERATING MODE SELECTION:
More informationPurchase Order Change Request. Transaction Set (860) (Inbound to TI)
Purchase Order Change Request Transaction Set (860) (Inbound to TI) ANSI X12 Version Format: 3020 Date: December 15, 1994 Copyright 1994 Texas Instruments Inc. All Rights Reserved The information and/or
More information4 Channel Stepper Driver Shield
4 Channel Stepper Driver Shield for Arduino and Raspberry-Pi Product Overview The IES-SHIELD-STX4 is a four [4] channel 5V or 6-12V (jumper selectable) Unipolar stepper motor driver with advanced control
More informationThe CONFIGURATOR. User Guide. Web-site: Tel: Fax:
Web-site: www.remmon.com Tel: 972-4-6065815 Email: remmon@remmon.com Fax: 972-4-6065819 The CONFIGURATOR User Guide 2005 Remmon Ltd. All rights reserved Version 1.0 i Web-site: www.remmon.com Tel: 972-4-6065815
More informationORION BEAN DOSER OPERATION MANUAL
ORION BEAN DOSER OPERATION MANUAL Contents Chapter 1: Introduction Chapter 2: Getting Started Chapter 3: s Chapter 4: Settings Chapter 5: Calibration 1 Chapter 1: Introduction Orion Bean Doser is a professional
More informationTruVision IP Thermal Camera Installation Guide
TruVision IP Thermal Camera Installation Guide P/N 1073335-EN REV B ISS 19OCT17 Copyright Trademarks and patents Manufacturer Certification 2017 United Technologies Corporation, Interlogix is part of UTC
More informationekey home en OPERATING INSTRUCTIONS
ekey home en OPERATING INSTRUCTIONS 01 English Translation of the original instructions ID159/271/0/135 Table of contents General...2 Note... 2 Product liability and limitation of liability... 2 Warranty
More informationUSER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n
USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H SW version 3.n CONTENT 1. General description 1 2. Getting started 2 2.1 Insert a SIM card 2 2.2 Insert the batteries 2 2.3 Enter the
More informationDryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51
Dryer M720 Programming and Operation Manual July 15, 2015 Revision 1.51 Contents 1 Important Safety Information 1 1.1 FOR YOUR SAFETY - CAUTION!............................. 1 2 Control Overview 2 2.1
More informationOP10. Pre-programmed, configurable controller for simple applications
revision 10 2013 OP10 Pre-programmed, configurable controller for simple applications The Optigo OP10 range of controllers can be set to handle everything from temperature or humidity control to control
More informationPADPULS2 M-BUS Pulse Input Modules
Product sheet MT8.23 Meter Type PADPULS2 PADPULS2 M-BUS Pulse Input Modules The M-PADPULS series of devices connects meters with contact output to the M-Bus system. This is a simple and flexible solution
More informationITALY CUP TECHNICAL SPECIFICATIONS AND USE INSTRUCTIONS OF THE DECONTO CHIPCARD SYSTEM
ITALY CUP TECHNICAL SPECIFICATIONS AND USE INSTRUCTIONS OF THE DECONTO CHIPCARD SYSTEM SGL Italia S.r.l., sole proprietorship, management and coordination by N&W S.p.a., reverses by law the property of
More information* When purchased as baby monitor set A , only one manual and warranty card is included. English 16
Congratulations on the purchase of your video monitoring system»mona«. You have chosen highly modern and reliable devices, which will provide valuable service for your home. Please read this manual thoroughly
More informationBOCCA DELLA VERITA' MAXIMA USER MANUAL
BOCCA DELLA VERITA' MAXIMA USER MANUAL Revision 1.31 EN Page intentionally left blank Bocca della Verità MAXIMA User manual rev 1.31 en 2 Table of contents IMPORTANT! READ CAREFULLY!... 4 Electrical safety...
More informationThe HAUSSMANN RIRI keypad
The HAUSSMANN RIRI keypad YOUR HAUSSMANN RIRI KEYPAD IS EVOLVING Until now, you could only use the keypad itself, but now it is possible to connect other equipment to it enabling you to control keypad
More informationIES-SHIELD-SCX18 Quick Start Guide
IES-SHIELD-SCX18 Quick Start Guide Connection: The SCX18 should be connected to the Arduino or Raspberry-Pi boards using the supplied wires or plugged into the Arduino board after soldering pin headers
More informationPXM20-E. Operator unit BACnet auf Ethernet/IP DESIGO PX
9 234 DESIGO PX Operator unit BACnet auf Ethernet/IP PXM20-E Network-compatible operator unit for viewing and operating one or more DESIGO PX automation stations. High-grade display with adjustable contrast
More informationMODEL : Nozzle. Hand shower. Top shower WS-501. Drawing of water connection. Cold/hot water switch. Water fall. Steam generator. Function shift switch
Drawing of water connection Top shower Function shift switch Cold/hot water switch Hand shower Install manual Steam bathroom MODEL : WS-50 Nozzle Cold water connection (blue pipe) Hot water connection
More informationControl instruments GUARDIAN 2 - GUARDIAN 3
Control instruments GUARDIAN 2 - GUARDIAN 3 Table of contents 1. General informations... 3 2. Technical data... 3 3. GUARDIAN 2 connection diagram...4 3.1. TTL connection diagram for GUARDIAN 2 instrument...5
More informationSemi Flush-mount Room Temperature Controllers with LCD
3 076 RDF300, RDF300.02, RDF340 RDF400.01 Semi Flush-mount Room Temperature Controllers with LCD for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment
More informationLDCL DIGITAL CONTROLLER O P E R A T I N G M A N U A L
This manual contains important safety informations about installation and use of this equipment. Ignoring this informations could result in injuries or damages. It is strictly forbidden to use this equipment
More informationVDG Supervisor. User s manual. A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved
ALGADE INSTRUMENTATION DOCUMENT NU-XFAB545-208 ind A VDG Supervisor User s manual A 07/2009 Original publication J.D. GUICHARD C. BERTRAND Ind Date Designation Author Approved 07/2009 ALGADE. All rights
More informationTruVision High Definition TVI Bullet Camera Installation Guide
TruVision High Definition TVI Bullet Camera Installation Guide TVB-2402/TVB-4402 TVB-2404/TVB-4404 TVB-2405/TVB-4405 P/N 1073164-EN REV B ISS 24JUN16 Contents Product overview 2 Camera description 4 Installation
More informationCeres M7000 Time & Attendance System Installation & Operation Instructions:
Page1 Ceres M7000 Time & Attendance System Installation & Operation Instructions: Table of Contents I. Minimum requirements:... 2 II. Ceres M7000e Installation (Steps):... 2 III. M7000 ibutton Time Recorder
More informationOperations Manual. Solstice I12 Cooking Computer. Covering. Single Vat (P/N ) and Dual Vat (P/N )
IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment: Model #: Serial #: Date Purchased: ENGLISH Operations Manual Solstice I12 Cooking Computer
More informationA-300 Speed Dome. Quick Start Guide
A-300 Speed Dome Quick Start Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the company you purchased the unit from. This manual
More informationCOMMISSION REGULATION (EU) No /.. of XXX
EUROPEAN COMMISSION Brussels, XXX [ ](2013) XXX draft COMMISSION REGULATION (EU) No /.. of XXX amending Commission Regulation (EC) No 1275/2008 with regard to ecodesign requirements for standby, off mode
More informationNetwork Keyboard. Quick Start Guide UD01317N
Network Keyboard Quick Start Guide UD01317N Quick Start Guide About this Guide This Guide is applicable to network keyboard. The Guide includes instructions for using and managing the product. Pictures,
More information6.0 SERVICE PROGRAMMING
6.0 SERVICE PROGRAMMING SERVICE MODE Access the service mode by pressing the mode switch on the control board (refer to Figure 3.1). After displaying any errors, the first function is displayed. Press
More informationCardMaster Programming Guide Rev CardMaster Operators Guide. CardMaster Installation Manual. CardMaster Service Guide
CardMaster Programming Guide Rev 10.06.03 Related Manuals include: CardMaster Operators Guide CardMaster Installation Manual CardMaster Service Guide CardMaster RF Installation Manual Wireless Modem Setup
More informationFB00084-EN PROGRAMMING MANUAL DDVC/08 VR - DDC/08 VR
FB00084-EN DDVC/08 VR DDC/08 VR PROGRMMING MNUL DDVC/08 VR - DDC/08 VR General precautions Read the instructions carefully before beginning the installation and carry out the actions as specified by the
More informationWEIGHING CONTROLLER TYPE MCE9625G
Kokkedal Industripark 4 DK-2980 Kokkedal Denmark Tel: +45 49 18 01 00 Fax: +45 49 18 02 00 WEIGHING CONTROLLER TYPE MCE9625G Installation guide for system with digital loadcells and LCD display Document
More informationPortable Hard Drive USB 2.0 User Guide
Portable Hard Drive USB 2.0 User Guide English Contents Introduction 3 Connecting Portable Hard Drive 3 Storing and Transferring Data 4 Disconnecting Portable Hard Drive 5 Technical Support 6 Limited Warranty
More informationNetwork Dome Camera Quick Start Guide
Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact us. About This Document This manual may contain several technical incorrect places or printing
More informationThank you for purchasing this
ENGLISH Thank you for purchasing this product. Please read these instructions carefully before using your TDC Timer. TDC Timer User Manual Document Version TDC-VSA01-3.3 INTRODUCTION The TDC Timer has
More informationMODEL : WS-500. DRAWING OF WATER CONNECTION As the from the picture,please make the connection according to the serial number v1,v2,etc.
DRAWING OF WATER CONNECTION As the from the picture,please make the connection according to the serial number v,v2,etc. Cold/hot water switch Top shower Switch valve Hand shower Install manual Steam bathroom
More informationenglish Thanks for choosing the Xbox GB Hard Drive. The Xbox GB Hard Drive lets you save games, save music and create
english Thanks for choosing the Xbox 360 120GB Hard Drive. The Xbox 360 120GB Hard Drive lets you save games, save music and create english NOTE Because the Xbox 360 system software uses some of the memory
More informationLED sign s Control Commands V1.23 (use for LED sign firmware V4.8 up)
LED sign s Control Commands V1.23 (use for LED sign firmware V4.8 up) Item Features Command Parameters Description 1 Timer display On/Off GALEDTM= ON or OFF ON = Timer display enable, OFF = Timer display
More informationPlease read and retain these instructions for future reference v002: 14/03/17. Cradle, Charger, Instruction manual, Lithium-ion Battery 3.7 V d.c.
Power Details: AC Charger Input voltage: 100-240V ~ 50/60Hz, 200mA Cradle Input Voltage: DC 5V, 500mA Cradle Output Voltage: DC 5V, 500mA Accessories: Cradle, Charger, Instruction manual, Lithium-ion Battery
More informationInstructions for Use
Instructions for Use V 1.3 March 2012 For definitions of all items and terms used in these instructions go to www.general-alert.com/support/definitions Contents Page Description 2 Security 2 Base Unit
More informationDesigner Systems. 4 Channel Stepper Driver Shield. Technical Data. to Arduino or Raspberry-PI
4 Channel Stepper Driver Shield for rduino and Raspberry-PI Designer Systems PRODUCT DESIGN ND MNUFCTURING.co.uk Technical Data Features rduino TM UNO Shield standard form factor for simple integration
More informationColorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual
Colorado Series CR-10 Portable ph / mv / Temperature Meter Operation Manual 2 Contents Page General Introduction and Initial Inspection.............................. 4 Safety Infomation..................................................
More informationINSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.
INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,
More informationInterface Kit for LVDS TFT Displays
Interface Kit for LVDS TFT Displays IES-TIK-AMxxxxxxxx Product Overview The IES range of TFT Interface Kits ( TIK ) is an advanced TFT LCD monitor control board, offering high quality images on a range
More informationCONFIGURATION MANUAL MAGLINK LX
CONFIGURATION MANUAL MAGLINK LX Rev. 09 April 2016 This page is left intentionally blank. Configuration Manual Summary SUMMARY 1 PREFACE... 4 2 GENERAL WARNINGS... 4 3 INTRODUCTION... 5 4 LOGIN PROCEDURE...
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More informationINSTRUCTION MANUAL. Models: H100 Light Meter
INSTRUCTION MANUAL Models: H100 Light Meter Table of Content 1. Product Introduction 3 1-1 Features. 3 1-2 Applications... 3 2. Safety Information 4 2-1 Cautions.... 4 2-2 Safety Symbols.... 4 3. Specifications....
More informationQK-G031 Temperature GSM Remote Controller
QK-G031 Temperature GSM Remote Controller Features Remote control from mobile phones Remote temperature monitoring and control Android APP interface Easy to install and configure (no PC required) Up to
More informationCube LAN Gateway. Operating manual BC-LGW-O-TW
Cube LAN Gateway Operating manual BC-LGW-O-TW Package contents Package contents Quantity Item 1x MAX! Cube LAN Gateway 1x 1x 1x 1x 1x 3x Plug-in USB power supply USB cable Network cable Mounting accessories
More informationEVF305 Product specifications - Version 1.02 EVCO S.p.A. Evco S.p.A. Product specifications EVF305
Evco S.p.A. Product specifications EVF305 Digital controllers for the management of the rotisserie with capacitive type user interface Drawn-up by Name and surname Date November 2012 page 1 of 14 1. REVISIONS
More informationBoomerang System Administrator Manual
Boomerang System Administrator Manual SG001-0003-01-B2.doc Page 1 of 43 Table of Contents INTRODUCTION...4 BOOMERANG CLIENT...5 FILE...6 3.1. Logout...... 6 3.2. Exit... 6 VIEW...7 4.1. Sensors events
More informationSmart Account. 0.25% of value thereafter
2 3 Smart Account Pay-As-You-Use Bundled Statements ZMW ZMW Monthly Account Fee 45.00 70.00 FNB ATM Withdrawals 0 6 Minimum Operating Balance 60.00 60.00 Minimum Balance for Rebate 10 000 10 000 Linked
More informationTX-5 LBS ANTI-THEFT ALERT SYSTEM (LBS+GSM+SMS/GPRS) Fast Installation Instruction & User Manual
TX-5 LBS ANTI-THEFT ALERT SYSTEM (LBS+GSM+SMS/GPRS) Fast Installation Instruction & User Manual In order to install and operate the LBS tracker in right method and properly, please read this Fast Installation
More informationLED Dot Matrix Digital Clock. Instructions. Contents. v (5x7-1x6 Module)
LED Dot Matrix Digital Clock v1.0.2 (5x7-1x6 Module) Instructions Designer: Yan Zeyuan. China Website: E-mail: yanzeyuan@163.com Contents Attention... 2 Functional Features... 2 Technical Specifications..
More informationThank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact us. About This Document This manual
Network Installation Bullet Camera & Quick Quick Setup Operation Guide Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact us. About This
More informationInserting system. FPi FPi FPi Title english Operator s Manual
Inserting system FPi 5020 FPi 5040 FPi 5060 Title english Operator s Manual FPi 5000 Operator controls Operator controls Figure 9 10 11 1 2 3 4 5 6 7 8 19 14 13 12 20 18 17 16 15 2 21 21 24 23 22 2 Legend
More informationHPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions
DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL
More information7-day room temperature controller
s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display
More informationPressure Transmitter and Reader of the PT-RF Series Manual
Local Solutions For Individual Customers Worldwide Pressure Transmitter and Reader of the PT-RF Series Manual Contents 1 Safety instructions... 3 1.1 Intended use... 3 1.2 Specialist personnel... 3 1.3
More informationWeekday / weekend room temperature controller
s 2 203 Weekday / weekend room temperature controller Heating applications REV17.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display
More informationForza. User s Manual. Read this manual carefully before using Forza.
User s Manual Forza Read this manual carefully before using Forza. 0476 This product is manufactured in compliance with the CE European Medical Device Directive and later directives and additions (2007/47
More informationPROFESSIONAL STOPWATCH. professional stoppuhr. User manual ENGLISH EN-1
PROFESSIONAL STOPWATCH professional stoppuhr User manual ENGLISH EN-1 Thanks for choosing the professional stopwatch Motus Trainer MT38 with lap time measurement and storage at 1/100 second precision.
More information*suitable both for membrane sensors or chlorine open cell
CTRL POOL THE SIMPLE, RELIABLE, COST EFFECTIVE SYSTEMS FOR SMALL POOLS CTRL POOL is a compact system, with single or dual controller and peristaltic dispensers all in one enclosure. CTRL POOL is extremely
More informationINDEX OF CONTENTS 15.2 VIEW OPTION LANGUAGE... 37
dixel XView INDEX OF CONTENTS 1. SOFTWARE TOOLKIT...5 2. INSTALLATION...5 3. HARDWARE KEY...5 4. PASSWORD MANAGEMENT...6 4.1 HOW TO SETUP A NEW USER...6 4.2 HOW TO MODIFY AN EXISTING USER...7 4.3 USER
More information24V, Motorized Actuators
24V, Motorized Actuators AMV 435, 3-point floating Description Main data: Supply voltage: 24 VAC/DC, 50 or 60 Hz Available control input signal versions: -3-point floating Stem travel: 20 mm Selectable
More information