CREATING & CUSTOMIZING SUBYPES & DOMAINS FOR YOUR GIS. Robert Borchert GIS Technician II Great River Energy

Size: px
Start display at page:

Download "CREATING & CUSTOMIZING SUBYPES & DOMAINS FOR YOUR GIS. Robert Borchert GIS Technician II Great River Energy"

Transcription

1 CREATING & CUSTOMIZING SUBYPES & DOMAINS FOR YOUR GIS Robert Borchert GIS Technician II Great River Energy

2 What do you do for a living What do you do for a living? I am a GIS Technician. Oh! What does that mean? I design, develop, distribute and maintain enterprise geodatabases for electrical distribution and transmission systems for member owned cooperatives that contain spatial and tabular data combined with topology and electric networks with links to a Maximo Data System Oh! I make maps OH!

3 CREATING & CUSTOMIZING Subtypes & DOMAINS FOR YOUR GIS TODAYS DISCUSSION HELP <F1> TERMINOLOGY Subtypes BASICS OF SUBTPYES PARTS OF A Subtype CREATING AND MODIFYING DOMAINS CATALOG, TOOLBOX, ARCMAP NON GIS PRODUCTS ASSIGNING» EXCEL, TEXT FILE Demonstration: Creating and modifying Subtypes and Domains Catalog Toolbox MS Excel and text BEST PRACTICES THROUGHOUT THE PRESENTATION BASICS OF DOMAINS PARTS OF A DOMAIN CREATING AND MODIFYING CATALOG TOOLBOX

4 HELP! Extensive help files found for almost every tool and topic for ArcGIS products and services. From an ArcGIS product Help drop down menu Press the F1 key From a dialog window Online support.esri.com geonet.esri.com Create a user account

5 TERMINOLOGY Feature Class A grouping of features that are of similar nature but may have multiple attributes. Example: Primary OH is a Feature Class but has different phases and can have multiple Subtypes Feature A single point, line or polygon in a Feature Class Field A column of data in a feature class table. Attribute The specific information entered in the cell under a field that defines one things about a feature. Subtype A grouping of features in a feature class based on attributes in a single field. Domain Specifies pre-made entries for an attribute A field that is Subtyped will override an assigned Domain

6 Subtypes - Basics A grouping in a feature class that specifics distinct classifications in a feature Overhead Primary AØ, BØ, CØ etc Reclosers Single Phase, Two Phase, Three Phase Best used when you have significant differences in features of the same type (like Primary Conductor) Grouped on a single field Only on SHORT OR LONG INTEGER Each attribute can have it s own domain in each Subtype Allows for automatic symbol classification

7 Subtypes and Symbols Subtyped Feature Class s are automatically separated in to different features

8 Subtypes and Symbols Adds Symbols by Label Right Click Value and select Reset Sorting

9 Subtypes and Symbols Adds Symbols by Label Right Click Value and select Reset Sorting

10 Subtypes and Symbols Can alternatively sort symbols based on Label as well

11 Subtypes - Parts Parts of a Subtype Subtype Field Specify which field your features will be Subtyped on Must be integer Default Subtype You specify what the default Subtype is when you create a new feature The default default is the first Subtype you create

12 Subtypes - Parts Parts of a Subtype Code An integer that is associated with the Subtype Description A short description of the Subtyped Feature Best Practice Keep it short

13 Subtypes - Parts Parts of a Subtype Default Value Default value for a specific Subtype Domain This is where can assign a specific Domain for a Subtyped Field

14 Subtypes - Creating & Modifying Where How ArcCatalog ArcMAP ArcGIS Pro (not to be discussed in this session) ArcCatalog ArcToolbox tools

15 Subtypes Best Practices Best practices Only Subtype for small distinct groupings such as phase Don t Subtype based on broad attributes such as wire type If using NISC for modeling substation devices should have a sub bay designation If you don t need to use a Subtype then don t Lake, streams, sections, etc.

16 Subtypes Best Practices Field typically called SubtypeCD or SubtypeCode However, you may use any field that makes sense Keep the Descriptions short Long descriptions may not be fully visible in the attributes window with out making the display wider More critical for web mapping applications Too many Subtypes can get cumbersome. Consider breaking it into different feature classes

17 Subtype s that frustrate ORIGIN DATA MODEL FOR PRIMARY MULTISPEAK FOR SECTIONALIZING

18 Domains - Basics Specified values that define acceptable values for an attribute in a field. Specific wire sizes Specific fuse sizes Specific pole attachments Field Type must match the field type. Short Integer Long Integer Float Double Text Date

19 Domains - Basics Assignment One domain can be applied to any number of fields and any number of feature classes Domain Types Coded Values Specified Values Range Can be used in all Field Types Allows entry of a value between a minimum and maximum value Can be used on all field types except TEXT

20 Domains - Basics Complexity Can be as basic as a simple Yes or No Can be as complicated as a complete list of pole attachments, fuse sizes, or wire types A domain can be created to match any list of attributes RUS Specs entries Maximum Length -??? Updating a domain will update it in all Fields that use it in all Feature Classes

21 Domain - Parts Parts of a Subtype Domain Name Name of Domain Description Basic description of the domain Not required

22 Domain - Parts Parts of a Subtype Field Type Must match the Field type you are going to associate the Domain to Domain type Coded Values Range

23 Domain - Parts Parts of a Subtype Field Type Must match the Field type you are going to associate the Domain to Domain type Coded Values Range

24 Domain - Parts Parts of a Subtype Minimum/Maximum Values Not with Text values Range Domains only Min and Max values

25 Domain - Parts Parts of a Subtype Split Policy Duplicate Duplicates value when pasted or split Default Value Uses default value when pasted or split Merge Policy Can sum Integer values on Merge Default only on Text

26 Domain - Parts Parts of a Subtype Code Short value used to define the attribute Can be sorted Alpha Numerically Description Description of the specific attribute This is what you will see

27 Domains Creating and Modifying Where How ArcCatalog ArcMAP ArcGIS Pro (not to be discussed in this session) ArcCatalog ArcToolbox tools

28 Domains Best Practices Integer vs Text Smaller database size Conductor features 8772 kb with Integer domain 1296 kb larger with Text domain Faster speeds System can read integer values faster than text When using Field Calculator you can simply enter the number if you know it. Keep descriptions short for view purposes

29 Domains that frustrate

30 Before you begin Plan it out PLAN IT OUT Determine how many Subtypes you need Determine which fields you want to use Determine which fields will use a domain Determine the Attributes you want to use in each Domain Write out your Domains? Create Domains first Automatically assigned when creating Subtypes

31 Plan it out Primary Overhead Conductor Subtypes 0 Select Phase 1 A Phase 2 B Phase 3 C Phase 4 AB Phase 5 AC Phase 6 BC Phase 7 ABC Phase

32 Plan it out Primary Overhead Conductor Domain Phase Coded Values, short integer Code Description 1 A Ø 2 B Ø 3 C Phase Primary Overhead Conductor

33 Plan it out Primary Overhead Conductor Domain WireType OH Coded Values, Text Code Description #1 ACSR #1 ACSR #2 ACSR #2 ACSR #4 ACSR #4 ACSR Etc

34 Plan it out Misc Features Domain RUSSpecs Coded Values, Text RUS Units 386 Unique Values

35 Very long Domains possible A1 Single Primary Support B4-1A Vertical Construction C7-1 Crossarm F1-1C Line Anchor Cable M5-15 Miscellaneous UG6 Single Phase Pad- ( Amp) Three UM8-2 Meter Pedestal VDC-C4-1 Vertical A1-1 Double Primary B5-1 Vertical Construction Construction Deadend Assembly (Cone) K10L Service Assembly Primary Assembly Mounted Transformer Phase Wood Post Construction--60 to 90 Support Deadend (Single) (Single) F1-1P Line Anchor (Large Conductors) M foot Crossarm (Radial Feed) UM48-1 Grounding UM8-3 Trough Type Meter Angle A1-1A Double Primary B5-1A Vertical Construction C7-2 Crossarm Assembly (Plate) K11 Service Assembly M5-17 Single Wooden UG6-1 Single Phase Pad- Assembly for Pad Mounted Pedestal VG105 Self Protected Support Deadend (Single) Construction Deadend F1-1S Line Anchor K11C Service Assembly, Crossarm Brace Mounted Transformer Single Phase Transformers UM8-3A Trough Type Transformer A1-1AP 0 to 5 Angle, B7 Vertical Construction (Single) Assembly (Screw) Cable M5-18 Pole Top Post (Radial Feed) and Enclosures Meter Pedestal VG106 Self Protected Double Primary Support Deadend (Single) C7A Crossarm Construction F1-2 Line Anchor Assembly K11L Service Assembly Insulator UG6-1B Single Phase Pad- UM48-2 Grounding UM8-4 Meter and Switch Transformer A1-1P 0 to 5 Angle, B7-1 Vertical Construction Deadend (Single) F1-2C Line Anchor (Large Conductors) M5-19 Neutral Standoff Mounted Transformer Assembly for Pad Mounted Installation Underfround VG136 Self Protected Double Primary Support Deadend (Single) C8 Crossarm Construction Assembly (Cone) K14 Service Assembly Bracket (Radial Feed) Multi Phase Transformers Source Transformer A1A Single Primary Support B8 Vertical Construction Deadend (Double) F1-2P Line Anchor K14C Service Assembly, M5-2 Miscellaneous UG6B Single Phase Pad- and Enclosures UM PED WITH VG150 One A1AP Single Primary Deadend (Double) C8-1 Crossarm Assembly (Plate) Cable Primary Assembly Mounted Transformer UM48-3 Grounding ONE SKT Autotransformer Support B9 Crossarm Construction Construction Deadend (Radial Feed) Assembly for Underground F1-2S Line Anchor A1P Single Primary Support Double Line Arm (Double) K14L Service Assembly M5-20 Suspension Insultor UM8-4A Meter and Switch VG65 Single Phase Assembly (Screw) (Large Conductors) Bells UG7 Single Phase Pad- Primary Cable Installation Underfround Transformer at One-Phase A2 Double Primary Support B9-1 Crossarm C9 Crossarm Construction Mounted Transformer UM5 Secondary Cable F1-3 Line Anchor Assembly A22 Crossarm Construction Construction Single Line Double Line Arm K15C Service Assembly, M5-21 Primary Suspension Source Tangent (Loop Feed) Terminal Pole F1-3C Line Anchor Cable Insulator Bolt UM8-5 Pad Mounted VG66 Transformer with Single Phase Junction Arm C9-1 Crossarm UG7B Single Phase Pad- UM5-6 Secondary Cable Assembly (Cone) A22P Crossarm B9-1P Crossarm Construction Single Line K16C Service Assembly (For M5-22 Hot Line Connector Switch Installation Double Gap and Internal Mounted Transformer Terminal to Meter Base Underground Source Fuse Construction Single-Phase Construction Single Line Arm F1-3P Line Anchor Range Type House) M5-23 Insulated Extension (Loop Feed) UM5-6A Secondary Cable Assembly (Plate) Junction Arm C9-1P Crossarm K17 Service Assembly (For Link UM8-6 C.T. Meter VG67 Transformer with UJ1-2 Secondary Terminal to Meter Base Installation Single Phase Double Gap and Internal A2P Double Primary B9-2 Crossarm Construction Single Line F1-3S Line Anchor Range Type House) M5-24 Miscellaneous Connector Blocks UM6-1 Uhp Load Break Support Construction Double Line Arm Assembly (Screw) K17L Service Assembly (For Assembly UM9-2 Pad Mounted Fuse UJ1-3 Secondary Elbow (200 A) Switched Capacitor VM10-14 Single Phase, Arm C9-2 Crossarm F1-4 Line Anchor Assembly Range Type House) M5-25 Miscellaneous Connector Blocks UM6-10 Uhb Insulated Enclosure Arcing Horn Assembly A3 Primary 1-Phase 20 to 60 Angle B9-2P Crossarm Construction Double Line F1-4P Line Anchor M2-1 Grounding Assembly Assembly UJ1-4 Secondary Protective Cap (200 A) UR2 Trenching Unit, One Guide Construction Double Line Arm Assembly (Plate) Ground Rod Type M5-26 Miscellaneous Connector Blocks UM6-11 Uhb Insulated Cable or Cable Assembly VM10-15 Three Phase, A4 Primary 1-Phase 60 to Arm C9-2PL Crossarm F1-4S Line Anchor M2-11 Grounding Assembly UJ1-6 Secondary Protective Cap (600 A) UR2-2 Trenching Unit, Arcing Horn Assembly 90 Angle B9-3 Crossarm Construction Double Line Assembly (Screw) Assembly Ground Rod Type M5-3 Miscellaneous Connector Blocks UM6-12 Uhx Cable Marker Power and Telephone Cable Guide A5 Deadend (Single) Construction Single Line Arm F2-1 Log Anchor Assembly M2-12 Pole Protection Primary Assembly UJ1-8 Secondary Assembly UR2-3 Trenching Unit, VM2-11 Grounding A5-1 Primary, Single Phase Arm C9-3PL Crossarm F2-2 Log Anchor Assembly Assembly Plate Type M5-4 Miscellaneous Connector Blocks UM6-13 Uhb Load Break Service or Secondary and Assembly--Ground Rod Tap B9-3P Crossarm Construction Single Line F2-3 Log Anchor Assembly M2-12A Pole Protection Primary Assembly UJ2-1 Secondary Insert (200 A) Telephone Type A5-2 Primary, Single Phase Construction Single Line Arm F2-4 Log Anchor Assembly Assembly Wrap-Around M5-5 Miscellaneous Connector Blocks UM6-14 Uhb Deadbreal UR2-4 Trenching Unit, VM2-11A Grounding Tap Arm DC-C25 Crossarm Type Primary Assembly F4-1 Service Anchor UJ2-2 Transformer Insert (600 A) Primary and Secondary or Assembly--Ground Rod A5-2A Primary, Single B9P Crossarm Construction Construction Double Circuit Assembly M2-12A2 Pole Protection M5-6 Miscellaneous Connector Blocks UM6-15 Uhq Stand-Off Telephone Type Phase Tap Double Line Arm 3-Phase Tap Assembly Plate Type Primary Assembly F4-2 Log Anchor Assembly UJ2-4 Transformer Insulator (200 A) UR2-5 Trenching Unit, VM2-12 Pole Protection A5-3 Primary, Single Phase C1 Crossarm Construction DC-C3 Double Circuit, M2-13 Ground Assembly M5-7 Miscellaneous Tap Single Primary Support Vertical Construction F4-3 Log Anchor Assembly Connector Blocks UM6-17 Uhb Insulating Primary, Secondary and Assembly--Butt Type Trench Type Primary Assembly A5-4 Primary, Single Phase C1-1 Crossarm DC-C4-1 Double Circuit, F5-1 Rock Anchor UJ2-6 Transformer Plug 600 Amp Connector Telephone VM3-10A One M2-17 Galvanic Anode M5-8 Miscellaneous Tap Construction Double Vertical Construction Assembly Connector Blocks UM6-18 Backing Plate for UR2-NT Trenches for Direct Sectionalizing Oil Circuit Assembly Primary Assembly A6 Vertical Deadend Primary Support E11 Single Loop Guy, F5-2 Rock Anchor UJ2-8 Transformer U-Guard Riser Shield Burial Cable Recloser M2-2 Pole Protection M5-9 Fuse Cutout (Double) C1-1A Crossarm Wrapped Type Assembly Connector Blocks UM6-19 Uhq Stand-Off UR2-ST Trenches for Direct VM3-16 Sectionalizing Air Assembly Plate Type M7-11 One Voltage A7 Crossarm Construction Construction Double E1-1 Single Down Guy, F5-3 Rock Anchor UK5 Secondary Pedestal Insulator Feed Through Burial Cable Break Switch M2-2A Pole Protection Regulator Pole Mounted Deadend (Single) Primary Support Through Bolt Type Assembly Underground Cable (200 A) VA1-1A Single-Phase - VM3-19 Two or Three Assembly Wrap-Around M7-13 Three Voltage A7-1 Crossarm C1-1AP Crossarm E12 Single Loop Guy, F6-1 Swamp Anchor UK6 Secondary Handhole UM6-2 Uhp Fused Elbow Double Primary Support Sectionalizing Oil Circuit Type Regulators Platform Construction Deadend Construction Double Wrapped Type Assembly Underground Cable Termination (200 A) VA1-2 Single-Phase - Reclosers M2-2A2 Pole Protection Mounted (Single) Primary Support E1-2 Single Down Guy, F6-2 Swamp Anchor UM12 Cable Route Marker UM6-20 Uhq Two Point Double Primary and Neutral VM3-19A Two or Three Assembly Plate Type M8 MTR SKT A8 Crossarm Construction C1-1P Crossarm Through Bolt Type Assembly UM1-5C Pad Assemblies Junction (200 A) Supports Sectionalizing Oil Circuit M2-3 Ground Assembly M8-15 Primary Metering Deadend (Double) Construction Double E1-3 Single Down Guy, F6-3 Swamp Anchor Trench Type UM1-5NC Pad Assemblies UM6-21 Uhq Three Point VA5 Single-Phase - Vertical Reclosers Guide Three-Phase 4-Wire A9 Crossarm Construction Primary Support Through Bolt Type Assembly M26-5 Security Light Wye UM1-6C Three Phase Junction (200 A) Deadend (single) VM3-1A One Sectionalizing Double Line Arm C1-2 Crossarm E2-1 Single Overhead Guy, G10 Single Phase Installation Guide Transformer Concrete Pads UM6-22 Uhq Four Point VA5-1 Single Phase Tap Fuse Cutout M9-11 Single-Phase A9-1 Crossarm Construction (Large Through Bolt Type Transformer at Deadend (Unmetered) Capacitor Assembly UM1-7C Ground Sleeve Junction (200 A) VA5-2 Single Phase Tap VM3-2 Two or Three Sectionalizing Disconnect Construction Single Line Conductors) E2-2 Single Overhead Guy, G105 Single Phase M2-7 Galvanic Anode Assembly UM6-24 Ugk Outdoor VA5-2A Single Phase Tap M9-12 Two or Three Phase Switches Arm C1-4 Crossarm Through-Bolt Type Transformer at 1-Phase Assembly Capacitor Assembly UM1-7NC Ground Sleeve Termination VA5-3 Single Phase Tap VM3-20 Two or Three A9-1P Crossarm Construction (Large Tangent E2-3 Single Overhead Guy, M2-9 Pole Top Protection Assembly UM6-26 Ugk Indoor Stress VA5-4 Single Phase Tap M9-13 Two or Three Phase Sectionalizing Oil Circuit Construction Single Line Conductors) Through-Bolt Type G106 Single Phase Assembly Capacitor Assembly UM27-1 Sacrifical Anode Relief Cone VA6 Single-Phase - Vertical Reclosers Arm C1-4PL Crossarm Transformer at Deadend E3-10 Single Down Guy, M3-10 One Sectionalizing for Cable Splice Protection UM6-28 Uhy In Line Deadend (double) UA1 Single Phase Cable VM3-20A Two or Three A9P Crossarm Construction Construction Double Pole Wrapped Type G136 Single Phase or Oil Circuit Recloser (bare to jacketed cable) Primary Splice (For Jacketed Deadend Terminal Pole VB1 Two-Phase - 0 to 5 Sectionalizing Oil Circuit Double Support Top Support Transformer on Three- E3-2 Single Down Guy, M3-11A 2 or 3 UM27-2 Sacrificial Anode Cable) angle, Single Primary Reclosers B1 Crossarm Construction C1A Crossarm Construction Phase Circuit UA2 Single Phase Cable Wrapped Type Sectionalizing Oil Circuit for Equipment Ground UM6-3 Uhb Dead Break Support Deadend Terminal Pole VM3-3 Two or Three Single Primary Support Single Primary Support G150 One Autotransformer E3-3 Single Down Guy, Reclosers Protection Termination (600 A) VB1-1 Two-Phase - 0 to 5 Sectionalizing Disconnect UA3 Single Phase Cable B1-1 Crossarm C1AP Crossarm Wrapped Type G39 Single Phase M3-12A 2 or 3 UM27-3 Sacrificial Anode UM6-32 Ugq Boot or angle, Double Primary Switches Tangent Terminal Pole Construction Double Construction Single Primary Transformer on Three- E4-2 Single Overhead Guy, Sectionalizing Oil Circuit for Cable Ground Sleeve - Insulated (600 Volt) Support VM3-4 One Sectionalizing Primary Support Support Phase Circuit UB1 VEE-PHASE CABLE Wrapped Type Reclosers Protection UM6-33 Uae Surge VB1-1A Two-Phase - 0 to Fuse Cutout TERMINAL POLE B1-1A Crossarm C1P Crossarm Construction G65 Single Phase E4-3 Single Overhead Guy, M3-15 Sectionalizing Air UM28 Test Station Arrester 5 angle, Double Primary VM5-1 Miscellaneous Construction Double Single Primary Support Transformer at 1-Phase UB4 VEE-PHASE CABLE Wrapped Type Break Switch UM3-14 Single Phase UM6-34 Uae Dead Break Support Primary Assembly Primary Support C1PL Crossarm Tangent TERMINAL POLE E5-1 Crossarm M3-1A One Sectionalizing Sectionalizing Enclosure Elbow Surge Arrester VB1A Two-Phase - 0 to 5 VM5-2 Miscellaneous B1-1AP Crossarm Construction Single Primary G66 Single Phase UC2-1 Three Phase Cable Construction Deadend Guy Fuse Cutout UM3-15 Single Phase UM6-35 UaxCutout- angle, Single Primary Primary Assembly Construction Double Support Transformer at Deadend Deadend Terminal Pole E5-2 Crossarm M3-2A 2 or 3 Sectionalizing Sectionalizing Enclosure Arrester Combination Support VM5-3 Miscellaneous Primary Support C2 Crossarm Construction G67 Single Phase UC2-2 Three Phase Cable Construction Deadend Guy Disconnect Switches UM33 Multi Phase UM6-36 af Load Break VB2 Two-Phase - Double Primary Assembly B1-1P Crossarm Double Primary Support Transformer on Three- Tangent Terminal Pole E6-2 Double Down Guy M3-3A 2 or 3 Sectionalizing Sectionalizing Enclosure Cutout Primary Support VM5-4 Miscellaneous Construction Double C2-1 Crossarm Phase Circuit UC3 Three Phase Cable Disconnect Switches Pad or Sleeve Mounted UM6-37 Uae Parking Stand VB9 Two-Phase - Crossarm Primary Assembly Primary Support Construction Double E6-2X Double Down Guy - G9 Single Phase Terminal Pole B1A Crossarm Construction Primary Support Narrow Profile Construction M3-3B Line Tension UM33 MVI Multiphase Arrester Construction--Double Line VM5-5 Miscellaneous Transformer at 1-Phase UC4 Three Phase Cable Switches Sectionalizing Enclosure UM6-38 Uae Bushing Arm Primary Assembly Single Primary Support C22 Crossarm Construction E6-3 Double Down Guy Tangent Terminal Pole Pad or Sleev e Mounted Arresters VB9-1 Two-Phase - M3-4 One Sectionalizing VM5-6 Miscellaneous B1AP Crossarm Single-Phase Junction E6-3X Double Down Guy - J10 Secondary Assembly UG17 Three Phase Pad Fuse Cutout UM3-44 Single Phase Pad UM6-39 Uhf Jacketed Crossarm Construction-- Primary Assembly Construction Single Primary C2-2PL Crossarm Narrow Profile Construction J11 Secondary Assembly Mounted Transformer Mounted Sectionalizer or Cable Grounding Kits Single Line Arm M3-41 One Sectionalizing Support Construction Double E7-2 Three Down Guys (Radial Feed) VM5-7 Miscellaneous J12 Secondary Assembly Recloser or Oil Circuit Recloser UM6-4 Ugo Fault Indicator VB9-2 Two-Phase - Primary Assembly B1P Crossarm Construction Primary Support (Large Conductors) UG17-2 Three Phase Pad J5 Secondary Assembly UM3-45 Single Phase Pad M5-1 Miscellaneous UM6-5 Uhb Feed Through Crossarm Construction-- Single Primary Support C24 Crossarm Construction E7-3 Three Down Guys Mounted Transformer Mounted Sectionalizer or J6 Secondary Assembly Primary Assembly Load Break Insert Double Line Arm VM5-8 Miscellaneous B2 Crossarm Construction Two-Phase Junction (Large Conductors) (Loop Feed) Primary Assembly Recloser J6Alum Secondary M5-10 Fuse Cutout with UM6-6 ai - aj - cj Ground VB9-3 Two-Phase - Double Primary Support C3 Vertical Construction E8-2 Four Down Guys UG17-2B Three Phase Pad UM3-46 Three Single Phase Assembly Lightning Arrestor Rod Assembly Crossarm Construction-- VM7-1 One Voltage B22 Crossarm Construction C3-1 Vertical Construction (Large Conductors) Mounted Transformer Pad Mounted Reclosers Single Line Arm Regulator Assembly, J6Copper Secondary M5-11 Single Steel (Loop Feed) UM6-7 Uhb Bushing Well Platform Mounted Single-Phase Junction (Large Conductors) E8-3 Four Down Guys UM3E-1 Single Pole Assembly Crossarm Brace Plug (200 A) VC1-2 Three-Phase - 0 to B2P Crossarm Construction C4-1 Vertical Construction (Large Conductors) UG17B Three Phase Pad Switching 200 Amp Fuse 2 angle, (Large Conductors) VM7-3 Three Voltage J7 Secondary Assembly M5-12 Metal Crossarm Mounted Transformer UM6-8 Ugc Riser Shield (U Regulators, Platform Double Primary Support C5-1 Vertical Construction E9-2 Guy for Narrow Enclosure B3 Vertical Construction Deadend (Single) Profile Construction J8 Secondary Assembly Brace Assembly (Radial Feed) Guard) VC1-4 Three-Phase - 2 to Mounted UM3E-2 Single Pole 5 angle, (Large Conductors) B3A Vertical Construction C7 Crossarm Construction E9-3 Guy for Narrow J9 Secondary Assembly M5-13 Wooden Crossarm UG23 Primary Riser UM6-9 Ugc Conduit Cable Switching 200 Amp Fuse B4-1 Vertical Construction Deadend (Single) Profile Construction K10 Service Assemblies Brace Assembly Feeding Single Phase Riser VDC-C3 Vertical Enclosure Construction--30 to 60 F1-1 Line Anchor Assembly K10C Service Assembly, M foot Crossarm Transformer UM8 Meter Installation UM3E-3 Fuse Enclosure Angle Underground Source

36 Flow chart of a feature Primary Overhead Subtypes 1 (A Ø) 2 (B Ø) 3 (C Ø) Phase Domain Phase Domain Phase Domain 1 = A Ø 1 = A Ø 1 = A Ø 2 = B Ø 2 = B Ø 2 = B Ø 3 = C Ø 3 = C Ø 3 = C Ø

37 Demonstration Feature Class Primary Overhead Conductor Create a PHASE Domain Create in ArcCatalog Create Subtypes Create in ArcCatalog Import a WireType Domain Import from existing feature Assign using ArcToolbox Tools

38 Demonstration Feature Class MiscFeatures Create RUS Units Domain Create using a document and ArcToolbox tools Documents MS Access Excell Text» Tab» Csv Assign in ArcMap

39 Questions Any Questions so far?

40 Demonstration Switching to demonstration mode. In case of epic demonstration failure the following slides are the demonstration

41 Create first Domain Open Feature Class Properties in ArcCatalog There is no field for domain in the phase Observe that Phase is Long Integer

42 Create first Domain Open Database Properties Click on Domains Tab Enter Domain Name Enter Description Optional Change Domain Type to Coded Value Enter Coded Values

43 Create first Domain Open Database Properties Click on Domains Tab Enter Domain Name Enter Description Optional Change Domain Type to Coded Value Enter Coded Values

44 Assign Domain Open Feature Properties Click on Fields Tab Click on the Field you wish to Domain Select Domain from drop down menu Default value Best practice to leave default as nothing

45 Assign Domain Open Feature Properties Click on Fields Tab Click on the Field you wish to Domain Select Domain from drop down menu Default value Best practice to leave default as nothing

46 Create Subtypes Close the Feature Class Properties Window Open the Feature Class Properties Window Click Suptypes tab Phase Domain assigned

47 Create Subtypes From Subtype Field drop down select you Field you want to Subtype from First Subtype is automatically created

48 Create Subtypes From Subtype Field drop down select you Field you want to Subtype from First Subtype is automatically created Assign Domain You can change the description

49 Create Subtypes Create the rest of your Subtypes Domain is automatically filled out for new Subtypes Set Default Value

50 Create Additional Subtypes Open Feature Class Properties and simply add them in using the same methods ArcToolbox Tools Good for ModelBuilder Best practice: Do it direct in ArcCatalog May not resort

51 Create WireType Domain Rather than manually entering a Domain you can import a feature that already uses it to port the Domain directly to your database simply by copying the feature class or importing it. Beware of duplicate Domains

52 Assign New Domain You can assign new Domains in ArcCatalog or ArcToolBox ArcCatlog you need to update all requisite fields one at a time Using Assign Domain To Field in ArcToolbox can assign it to each subtype

53 Create RUS Specs Domain You can create Domains from very long text files if formatted correctly using Table To Domain

54 Create RUS Specs Domain Input table is the text file Select Code Select Description Input Workspace is your datebase Enter Domain Name Update as Append Assign it to the fields

What is a Deadfront and Separable Arrester

What is a Deadfront and Separable Arrester What is a Deadfront and Separable Arrester ArresterFacts 025 What are Deadfront and Separable Arresters Photo ArresterWorks Separable Arrester sketch Courtesy Tyco Electronics Deadfront Arrester Photo

More information

Specif ications. S&C Alduti-Rupter Switches Outdoor Distribution (14.4 kv through 69 kv)

Specif ications. S&C Alduti-Rupter Switches Outdoor Distribution (14.4 kv through 69 kv) S&C Alduti-Rupter Switches Outdoor Distribution ( through 69 ) Specif ications Conditions of Sale STANDARD: The seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

Spring Test 17 due 06/14/2013

Spring Test 17 due 06/14/2013 Spring Test 17 due 06/14/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. The NEC defines cable as a cylindrical assembly composed of a conductor centered

More information

600-Amp Elbow Connectors 600 Series Deadbreak Components

600-Amp Elbow Connectors 600 Series Deadbreak Components 600-Amp Elbow Connectors 600 Series Deadbreak Components 600 Series deadbreak elbows, straight receptacles, junctions, vault stretchers and accessories are used to connect equipment and cable on primary

More information

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template.

It is acceptable to place all required information in the main element (such as G4010) and delete the sub-elements provided in this template. 6. ENGINEERING SYSTEMS REQUIREMENTS G40 SITE ELECTRICAL UTILITIES SYSTEMS REQUIREMENTS SITE ELECTRICAL UTILITIES TEMPLATE 02/18 Instructions for using this template: There are template files for each UNIFORMAT

More information

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D. Electrical Integration of PV Systems Ridha Hamidi, Ph.D. 1 Many articles in the NEC are applicable to the electrical integration of a PV system, particularly Article 690. 2 The NEC defines the various

More information

(Above 100km Distance) (Streetlight Pole) (Above 100km Distance) (Streetlight Pole)

(Above 100km Distance) (Streetlight Pole) (Above 100km Distance) (Streetlight Pole) Part 9 Miscellaneous Drawing Register Number Description M1-1 SSN Network Device with LV Aerial Supply (ABC) Arrangement M1-2 SSN Network Device with LV Aerial Supply Arrangement M1-3 SSN Network Device

More information

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 5 APPR:LWB:DBP:07-31-13

More information

PAR+ & MSC+ Controller. Installation Manual

PAR+ & MSC+ Controller. Installation Manual PAR+ & MSC+ Controller Installation Manual Contents Introduction... 1 System Configuration...1 Parts List and Tools Required for Installation...1 Installation Checklist...1 Mount Controller Pedestal on

More information

Meter Enclosure and Equipment Standards

Meter Enclosure and Equipment Standards Meter Enclosure and Equipment Standards (a) (b) General Requirements: CITY OF OCALA UTILITY SERVICES METER ENCLOSURE AND EQUIPMENT STANDARDS: (1) To avoid the costs associated with having to replace unacceptable

More information

Section 20 Distribution (Underground)

Section 20 Distribution (Underground) PREVIOUS SEARCH NEXT Section Distribution (Underground) Table of Contents Page Underground Connectors...-2 Padmount Transformer Connectors...-3 Pedestal Connectors...-4 Pedestal Block Connector...-6 Street

More information

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and

More information

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters Lightning current and surge arresters Application-specific SPD designs SPD for use in satellite and cable TV systems with measuring output Combined lightning current and surge arrester for high discharge

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

AIR TERMINALS: COPPER

AIR TERMINALS: COPPER AIR TERMINALS: COPPER A ADAPTER TYPE B LESS ADAPTER LA TYPE A B C A B C A B C 3 8 COPPER POINTS (CLASS I ONLY) 1 2 COPPER POINTS (CLASS I OR II) 5 8 COPPER POINTS (CLASS I OR II) THE 3 8 COPPER AND ALUMINUM

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories

NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories NT-300 & NT-2300 Series Single & Dual Circuit Track System & Accessories PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated flat, solid integral conductors. Variety of connectors

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION

MICHIGAN DEPARTMENT OF TRANSPORTATION MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR GROUNDING, BONDING, LIGHTNING PROTECTION AND SURGE PROTECTION FOR INTELLIGENT TRANSPORTATION SYSTEM EQUIPMENT ITS:CLC 1 of 6 APPR:MDW:JVG:06-08-18

More information

ADAPTERS AMPLIFIERS ATTENUATORS DIAL ADAPTERS GONG ATTACHMENTS MAGNETIC AMPLIFIERS TRANMITTER ARMS TRANSMITTER ATTACHMENTS

ADAPTERS AMPLIFIERS ATTENUATORS DIAL ADAPTERS GONG ATTACHMENTS MAGNETIC AMPLIFIERS TRANMITTER ARMS TRANSMITTER ATTACHMENTS Table of Contents A... 2 B... 2 C... 3 D... 4 E... 4 F... 4 G... 4 H... 4 I... 5 J... 5 K... 5 L... 6 M... 6 N... 6 O... 7 P... 7 R... 7 S... 8 T... 9 U... 10 V... 10 W... 10 A ADAPTERS AMPLIFIERS ATTENUATORS

More information

PhaseID System. Phase Attribute Acquisition. Field Probe Instruction Manual U.S. Patent

PhaseID System. Phase Attribute Acquisition. Field Probe Instruction Manual U.S. Patent PhaseID System Phase Attribute Acquisition Field Probe Instruction Manual U.S. Patent 6667610 Operating Manual The PhaseID System Primary Distribution Phase Attribute Identification Model MB-0414F Field

More information

Utility Network Management in ArcGIS: Migrating Your Data to the Utility Network. John Alsup & John Long

Utility Network Management in ArcGIS: Migrating Your Data to the Utility Network. John Alsup & John Long Utility Network Management in ArcGIS: Migrating Your Data to the Utility Network John Alsup & John Long Presentation Outline Utility Network Preparation - Migration Patterns - Understanding the Asset Package

More information

CROSSARMS 1-1. SIZE: 100 x 50 x 10.73kg/m, 2.4m LONG MOUNTED FOR CUT OUT BRACKET DESCRIPTION: H-POLE MOUNTED VOLTAGE REGULATOR PLATFORM D-DT #: 3016

CROSSARMS 1-1. SIZE: 100 x 50 x 10.73kg/m, 2.4m LONG MOUNTED FOR CUT OUT BRACKET DESCRIPTION: H-POLE MOUNTED VOLTAGE REGULATOR PLATFORM D-DT #: 3016 DESCRIPTION: STEEL CHANNEL CROSSARM D-DT #: 3000 CROSSARMS 1-1 NOTES: SAP #: 0189877 STEEL CHANNEL CROSSARM; H-POLE SIZE: 100 x 50 x 10.73kg/m, 2.4m LONG MOUNTED FOR CUT OUT BRACKET MATERIAL: STEEL PARALLEL

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

UNDERGROUND CONSTRUCTION MANUAL SERVICES

UNDERGROUND CONSTRUCTION MANUAL SERVICES UNDERGROUND CONSTRUCTION MANUAL ack to MAIN INDEX Go to SECTION INDEX CONSTRUCTION DESCRIPTION DWG CONSTRUCTION DESCRIPTION DWG Construction code guide - Underground service from overhead system 53 SERVICE

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Terminal Junction System (MIL-T and Commercial)

Terminal Junction System (MIL-T and Commercial) Introduction Product Facts The TJS connections are inherently more reliable than conventional threaded and solder terminations. The user s wiring is crimped to gold plated pin contacts, conforming the

More information

Power-Style QED-2, Series 2 Low Voltage Switchboards

Power-Style QED-2, Series 2 Low Voltage Switchboards Power-Style QED-2, Series 2 Low Voltage Switchboards Catalog 2742CT1001 (Addendum to 2742CT9501R12/09) 2010 Class 2742 CONTENTS Description............................................. Page Features...................................................

More information

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT ISOLATION Info: 9070 = Isolation RELAY RACK ISOLATION KIT 19 RACK MOUNT 9070-1019 19" Rack Mount 23 RACK MOUNT 9070-1023 23" Rack Mount RELAY RACK ISOLATION (KIT) RELAY RACK ISOLATION KIT, SLOTTED 19 RACK

More information

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries

INSTRUCTION MANUAL DIGI-LOCK. Keyless Entry System. Installation. Programming. Troubleshooting. BASE Industries INSTRUCTION MANUAL DIGI-LOCK Keyless Entry System Installation Programming Troubleshooting BASE Industries 45 Pomona Rd. Corona, CA. 9880 Revision F TABLE OF CONTENTS OWNER REGISTRATION CARD INTRODUCTION

More information

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co.

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co. Collector System Design Considerations for Wind Farms Sean Carr Ernst Camm S&C Electric Co. 1 Overview Challenges in wind farm collector systems Design considerations for collector systems Summary The

More information

APS4 Inductive Proximity Sensors

APS4 Inductive Proximity Sensors APS4 Inductive APS4-S-E-D APS4-S-E2-D APS4-M-E-D APS4-M-E2-D Compact x27 mm plastic DC 4 models available Compact polycarbonate housing; comes with mounting plate High-frequency oscillation type DC 3-wire,

More information

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 September 2011 STATE OF NEW JERSEY BUREAUS OF ITS ENGINEERING AND SAFETY & DATA DEVELOPMENT DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 MATERIAL SPECIFICATIONS FOR WEIGH-IN-MOTION SYSTEM The

More information

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 3a. IEM Indoor Metal Clad Medium Voltage Switchgear 25KV 16346-1 3a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

Circuit Breakers,Reclosers, Switches, and Fuses

Circuit Breakers,Reclosers, Switches, and Fuses Section 17 Circuit Breakers,Reclosers, Switches, and Fuses 170. ARRANGEMENT This rule requires circuit breakers, reclosers, switches, and fuses be accessible only to qualified persons. Section 17 is part

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

SM Sygnus Hybrid Quick Installation Guide Version

SM Sygnus Hybrid Quick Installation Guide Version SM Sygnus Hybrid Quick Installation Guide Version 1.0.4 2017 WARNINGS Do not work on the system or connect or disconnect cables during periods of lightning activity. This equipment must be grounded. Never

More information

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216

More information

Small Power Station Surge Protection Analysis and Plan

Small Power Station Surge Protection Analysis and Plan [Type the document title] Small Power Station Surge Protection Analysis and Plan By ArresterWorks Jonathan Woodworth ArresterWorks Page 1 Contents 1.0 Executive Summary... 3 1.1 Project Overview... 3 1.2

More information

Effective May 2018 Supersedes October 2017

Effective May 2018 Supersedes October 2017 Technical Data TD280028EN Supersedes October 2017 COOPER POWER SERIES NOVA NX-T Recloser, Form 6 NX-T, and Form 6LS NX-TRecloser Control and Accessories Ordering Guide Eaton provides reliable, economical

More information

Modular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308

Modular Splicing FAX MODULAR SPLICING. Modular Splicing Kits 305 Cable Adapter Kits 308 Modular Splicing Modular Splicing Kits 305 Cable Adapter Kits 308 MODULAR SPLICING 3M Modular Splice Kits form a 5 to 25 kv 600 Amp separable insulated connector system. The system is easy to expand and

More information

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module , Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION

More information

ELECTRO-MECH SCOREBOARD CO.

ELECTRO-MECH SCOREBOARD CO. ELECTRO-MECH SCOREBOARD CO. MODEL 2150 SHOT TIMER OWNER S HANDBOOK Thank you for choosing an Electro-Mech Scoreboard for your athletic complex. We are confident that your new shot timer will give many

More information

Plug and Operate Transformer Technology

Plug and Operate Transformer Technology Plug and Operate Transformer Technology Deepal Shah PFISTERER deepal.shah@pfisterer.com by and Andre Goessler PFISTERER andre.goessler@pfisterer.com 1 THE POWER CONNECTION We have always worked closely

More information

VRp Three-Phase Precision AC Voltage Regulator

VRp Three-Phase Precision AC Voltage Regulator VRp-22500-0338 Three-Phase Precision AC Voltage Regulator INSTALLATION INSTRUCTIONS Inspection and Unpacking Please inspect the wooden crate for obvious shipping damage. Some crates contain up to six (6)

More information

NT-2300 Series Dual Circuit Track System & Accessories

NT-2300 Series Dual Circuit Track System & Accessories ILLUMINATING THE FUTURE...SINCE 1989 NT-2300 Series Dual Circuit Track System & Accessories Type Project Catalog No. Lamp/Wattage PRODUCT DESCRIPTION Low profile, extruded aluminum track with 20-Amp rated

More information

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters

MARWELL CORPORATION Manufacturer of UL Listed Meter Socket Adapters Yellow Section Capacitor Sockets and Monitors, Temporary Service Adapters, Quick Set/Gen Set, Temporary Load Center, TSA, Transformer Load Management CAPACITOR CONTROLLER SOCKET Four - Six Jaws Wire Lugs

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS OUTDOOR HARDWIRE INSTALLATION INSTRUCTIONS Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all safety information, warnings and cautions.

More information

COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR. Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa

COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR. Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa Alexandre Taijun Ohara S&C Electric Company Curitiba/PR Brazil

More information

Road Ahead for Network Management. Larry Young Esri Product Management

Road Ahead for Network Management. Larry Young Esri Product Management Road Ahead for Network Management Larry Young Esri Product Management Network Management Session Presentation Agenda - Overview - Why you want a Utility Network? - What exactly is a Utility Network? -

More information

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0 Contents DMC2

More information

Basketball Shot Clock Set LX2180 Manual

Basketball Shot Clock Set LX2180 Manual Basketball Shot Clock Set LX2180 Manual 72 Industrial Boulevard Wrightsville, GA 31096 Phone: (800) 445-7843 Fax: (800) 864-0212 www.electro-mech.com LX2180 Revision 5 February 8, 2013 Table of Contents

More information

COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION

COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION COCKPIT DOOR SURVEILLANCE SYSTEM - DESCRIPTION AND OPERATION 1. General A. The FlightVu video surveillance system is designed to augment aircraft security by providing a secured unobstructed view of the

More information

SERVICE PARTS MANUAL

SERVICE PARTS MANUAL SERVICE PARTS MANUAL DX SERIES SNOW PLOW FOR SERIES SNOW PLOWS SERIAL NUMBERS AFTER DX0000 00 Sno-Way International 0G TABLE OF CONTENTS Page HYDRAULIC SYSTEM (DX)... POWER PACK FRAME... 3 BLADES... LIFT

More information

4100/4120-Series and 4010ES Relay Modules Installation Instructions

4100/4120-Series and 4010ES Relay Modules Installation Instructions 4100/4120-Series and 4010ES Relay Modules Installation Instructions Introduction This publication describes the installation procedure for the relay cards listed in the following table. Model Number Description

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

Safety switches with separate actuator

Safety switches with separate actuator A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT

More information

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority

Custom Switchracks: Built to Comply with NEC/CEC Standards From Design to Installation, Appleton is The Switchrack Authority From Design to Installation, Appleton is The Switchrack Authority With over 80 years in the industry, Appleton is one of the first and the most respected names in custom switchracks for hazardous and adverse

More information

Safety switches with separate actuator

Safety switches with separate actuator 4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME Reclosers Form 4C Microprocessor-Based Recloser Control Analog Current Metering Accessory KME4-82-1, KME4-82-2 Installation and Operation Instructions Service Information S280-77-8 Figure 1. Kyle Form

More information

Call Before You Dig/811 Virtual Reality Experience Setup Documentation

Call Before You Dig/811 Virtual Reality Experience Setup Documentation Call Before You Dig/811 Combination Locks CGA has purchased combination locks for all cases. The code for all locks is 5823. Tablet Setup Remove tablet (TA) from sleeve and power on Screw in tablet stand

More information

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1

Residential 1-Line Multifamily Instructions. User s Manual APPROVED. Copyright 2016 Durand & Associates. Page 1 Residential 1-Line 2017 Multifamily Instructions APPROVED User s Manual Copyright 2016 Durand & Associates Page 1 Using Residential 1-Line 2017 with Excel Excel 1997-2003 This product was designed with

More information

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...

5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays... .1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....

More information

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or

More information

INDOOR SPORTS SCOREBOARD INSTALLATION RECOMMENDATIONS REV

INDOOR SPORTS SCOREBOARD INSTALLATION RECOMMENDATIONS REV INDOOR SPORTS SCOREBOARD INSTALLATION RECOMMENDATIONS 98-0001-23 REV 1805.03 TABLE OF CONTENTS DISCLAIMER The suggestions and recommendation within this document are intended as a guide for the installation

More information

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide This Quick Installation Guide is intended for experienced installers. For more information refer to the relevant sections in the BreezeMAX Wi² and BreezeACCESS Wi² System Manual. Wi² Package Content Check

More information

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc

Redundant Bus Protection Using High-Impedance Differential Relays. Josh LaBlanc Redundant Bus Protection Using High-Impedance Differential Relays Josh LaBlanc Purpose Discuss the configuration of the bus under study, and touch on the needs for redundant protection on the bus. Briefly

More information

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC

TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC TokiLux TM Series TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC General Description Tokistar's TokiLux Series may be operated at 24 VDC or 24 VAC. Light Bars are installed end-to-end within the

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Safety switches for hinged doors

Safety switches for hinged doors C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Progressive Industries, Inc. EMS Electrical Management System

Progressive Industries, Inc. EMS Electrical Management System Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.

More information

Ultima X5000 Rectangular Duct Mount Kit User Instructions

Ultima X5000 Rectangular Duct Mount Kit User Instructions Ultima X5000 Rectangular Duct Mount Kit User Instructions MSA Kit 10176947 - Ultima X5000 316 Stainless Steel Parts List / Instructions Rectangular Gasket (1) Rectangular Duct Mount Base Plate (1) Base

More information

Adapter Kit - Remote QSI Electronics Installation Instructions

Adapter Kit - Remote QSI Electronics Installation Instructions Adapter Kit Remote QSI Electronics Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics. The instructions

More information

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS

M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS M ISCELLANEOUS A CCESSORIES O BSTRUCTIONS LIGHTS MISCELLANEOUS ACCESSORIES OBSTRUCTION LIGHTS G1 Outdoor Surge Protector for AC/Traction network VP range Dimensions (in mm) 19 M8 44 73 diam. 47 6 mm² Electrical

More information

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module

INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold. Tru-Break switchgear module INSTALLATION PRODUCTS CAA GROUP OCTOBER 2018 Elastimold Tru-Break switchgear module Tru-Break switchgear module agenda Design platform and value Product specifications Operation Configuration examples

More information

TSR A & B - FACILITIES STUDY REPORT

TSR A & B - FACILITIES STUDY REPORT TSR-11-0502A & B - FACILITIES STUDY REPORT Transmission Service Request No. TSR-11-0502A&B 2 x 25 MW Wind Energy Generating Facilities From POI on Gladstone Walsenburg 230 kv Line to Ojo Substation 345

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist. CONSOLE CONNECTOR KIT 8101 INSTALLATION INSTRUCTIONS FOR USE WITH: HAMMOND Organ Models A-100, D-100, RT2, RT3 LESLIE Speaker Models 122, 122RV KIT CONTENT Console Connector Assembly 047357 Echo Control

More information

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits

Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Basics of Industrial Electricity and Troubleshooting Electrical Control Circuits Course Details Date: January 28 January 31, 2019 Time: 8:00 A.M. - 4:30 P.M. Capacity: 12 attendees Provider: National Technology

More information

TOKISTAR LIGHTING INSTRUCTION MANUAL

TOKISTAR LIGHTING INSTRUCTION MANUAL TokiLux TM WG Series TOKISTAR LIGHTING INSTRUCTION MANUAL 24 VDC or 24 VAC General Description Tokistar s TokiLux WG Series may be operated at 24 VDC or 24 VAC. Light Bars are installed end-to-end within

More information

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations Navigator II Installation MANUAL For Static and Pan/Tilt Configurations Document Number: 432-0001-00-12, rev 100 FLIR Systems, Inc., 2008. All rights reserved worldwide. No parts of this manual, in whole

More information

Crane Control Class 9004

Crane Control Class 9004 Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................

More information

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices

Owner s Manual. Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices Owner s Manual Models 1503 and 1504 Basic Stand Alone Digital Keypad Entry Devices DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com

More information

Safety wherever needed

Safety wherever needed Safety wherever needed Low Voltage Surge Arrestors Uninsulated version Isolated version Rope-throwing-off-function MM: Bild angeben Content 280 Technical data see page 281 System The Low Voltage Surge

More information

Search & Rescue Map Specifications and Production Workflows

Search & Rescue Map Specifications and Production Workflows Search & Rescue Map Specifications and Production Workflows About The Search & Rescue map product and production procedures discussed in this document can be utilized to support search, rescue, and relief

More information

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 Supersedes 6/2015 Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2 XXCFXXX10-DIN Contents Description Page 1.0 Setup...2 1.1 Before Installation...2 1.2 Installation...3 For AC Applications...3

More information

TCS Series of Manual CP Rectifier (O63 Model, Oil-Cooled)

TCS Series of Manual CP Rectifier (O63 Model, Oil-Cooled) TCS Series of Manual CP Rectifier (O63 Model, Oil-Cooled) ARMIN's 63 Step Manual Controlled Cathodic Protection TR Units (Oil-Cooled) are specially designed for safe and long term operation in environments

More information

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION

POWERHOUSE. -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION POWERHOUSE TM -- the finest in Digital Command Control -- PRODUCT MANUAL FOR PB-110A TEN AMP POWER STATION NCE Corporation 1260 CREEK STREET Suite 105 WEBSTER NEW YORK 14580 FAX : (716) 671-9337 E-mail:

More information

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all

More information

NU-LEC. Loop Automation. Reclosers & Sectionalizers

NU-LEC. Loop Automation. Reclosers & Sectionalizers NU-LEC Loop Automation Reclosers & Sectionalizers 1 NU-LEC LLC NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd. Sales and service center for United States, Canada, and the Caribbean. Warehouse

More information

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers

DECK All-In-One Enclosure. Quick Installation Guide for Field Installers DECK All-In-One Enclosure Quick Installation Guide for Field Installers 1 Contents Legal Statement... 2 Preliminary Considerations... 2 Required Installation Tools and Materials... 2 Networking Information...

More information

Universal Tongue-Operated Safety Interlock Switch

Universal Tongue-Operated Safety Interlock Switch Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,

More information

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection CONTA-ELECTRONICS CONTA-PROTECT overvoltage protection When choosing the correct device for overvoltage protection, it is important to consider the regulations VDE 110-1, IEC 61643-1, EN 61643-11 and VDE

More information

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

Section 21. Telecommunication Hardware.  BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

Feed Screeners. Model 90 Screener: Model 108 Screener: Model 125 Screener: Manufactured until 3/2002

Feed Screeners. Model 90 Screener: Model 108 Screener: Model 125 Screener: Manufactured until 3/2002 Back Home FLEX-AUGER Repair Parts Model 90 Screener: 25895 Model 108 Screener: 34347 Model 125 Screener: 25712 Manufactured until 3/2002 25895 34347 25712 25895 34347 25712 Model 90 Model 108 Model 125

More information

MULTIBAND Dual Radio V4

MULTIBAND Dual Radio V4 Dual Radio V4 WI FI Compatibility Speed Package Contents: Multiband Dual Radio v4 Mounting Bracket (Include: 2 stainless & steel U-Bolt, 1 Bracket and 4 screw nuts) 100-240VAC 48VDC, 350 ma PoE Injector

More information

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions

More information

Power-Over-Ethernet Weatherproof 18" x 16" x 8" Enclosure with Equipment Mounting Plate and Cooling Fans

Power-Over-Ethernet Weatherproof 18 x 16 x 8 Enclosure with Equipment Mounting Plate and Cooling Fans Power-Over-Ethernet Weatherproof 18" x 16" x 8" Equipment Mounting Plate and Cooling Fans Applications and Features Applications: Remote Wireless LAN WiFi equipment installations using Power- Over-Ethernet

More information