AIR Compressor. Efficient Cooling System. PCG Series 01/02

Size: px
Start display at page:

Download "AIR Compressor. Efficient Cooling System. PCG Series 01/02"

Transcription

1

2 AIR Compressor V-belt Connection Level energy efficiency motor Efficient motor specialized for compressors with long service life Rational configuration of compressors within the same range satisfies the needs of air displacement. Advanced gas-oil separation system with less oil, which is easy to maintain. 4KW-KW, belt transmission KW-0KW, direct coupling transmission PCG Series Coupling / Gear variable transmission High-end configuration of intake control system World-renowned compressor Gas-oil separator is in conformity with /DIR standard. Efficient Cooling System Radiator: sufficient cooling area, high-end manufacturing quality Cooling fan: in conformity with EU Eff standard, high efficiency, low noise and longer service life Intelligent operation: owing to adjustment of oil temperature by the, lubrication oil always keeps in the optimal working condition 0/0

3 AIR Compressor The compressor is equipped with monitoring system, of which the LCD monitor helps you monitor the operation of compressor in real time and has multiple functions such as data display and monitoring. Protection function when starting up Automatic alarm for overload, over and high temperature, shutdown protection Mechanical over protection Centrifugal Fan Driving Wheel Belt Pulley Shield Electric Motor Spring Air Filter Gas-oil Separator Core Safety Valve Clean outlet Drainage valve Electrical Safety World-renowned brand of components Passing UL Certification Self-test every time before start of the compressor Multi-layer self-protection functions Data recovery function after failure 03/04

4 Air Intake Valve Compressor Radiator Gas-oil Separator AIR Compressor Holes for Forklift Emergency Stop Button Control Panel Electrical Cabinet Power Input Drainage The chassis with anti-twist and liquid-impermeable design could bring 00% safety protection for the ground. Completely closed cavity in the chassis ensures drainage at one time in case of occurrence of internal leakage. Flexible pipes have good heat radiation performance with no leakage,low vibration and low noise. Large air-conditioned delivery system can make outlet air temperature only -0 C higher than that in the inlet,environmental-friendly. Multiple-layer anti-vibration design can reduce the noise pollution arising from vibration and friction. Double vibration absorbing bracket and chassis ensure lowest vibration in operation. The flexible chassis with self-supporting bracket ensures no structural friction noise in transportation. The integrated design of air duct and sound absorbing material can reduce the noise effectively. Energy Conservation and Environmental Protection Professional and accurate calculation of electromotor and compressor configuration data ensures highest operational efficiency with less consumption. The smooth surface is fire-resistant, dustproof, oil-proof and environmental-friendly. The unique internal dustproof design and the dustproof bars with specially-fabricated casing ensure perfect dustproof effect. 0/06

5 AIR Compressor Switch box conforming to DIN and VDE standards Luminous LCD for continuous simple text and important operating parameters display. Display of all operation data for help in form of figures. Display of operating condition of variable frequency compressor in percentage. Control Panel Easy Maintenance User-friendly design, reserve space for easy and convenient repair and maintenance. Automatically reminding maintenance time and fault inquiry of control system. Information maintenance through AIR CONTROL. Economic control panel can be seen from angle. Display of all important running statuses. The best operation mode is optional. Visibility of operating parameters-including hardware and software needed(optional). Automatic shutdown of compressor before activation of safety valve in fault condition. 0/0

6 AIR Compressor channels for change-over of compressor switch channels for display of compressor reduction time control channels for failure warning of 4 auxiliary outputs equipment Management of auxiliary input devices Air station including auxiliary equipment can be managed through Air Control 3. Each compressor can conduct cycle operation within the scope. All compressors operations are consistent with that of each other. The joint control of compressor could greatly improve efficiency with low cost. System load Activation of remote operation Final Text display of operation warning / fault Compressor temperature fault Motor fault Service interval fault.when service expires,the service hotline will appear. Date/real-time clock Compression temperature Sensor error Total running hours Full load hours No-load hours Standby hours Display of operating condition of variable frequency compressor in percentage Progress curve of and time Progress curve of final temperature and time 09/0

7 Technical Data of PCK Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCK/A PCK/0A PCK/A PCK/0A PCK0/A G" PCK0/0A G" PCK/A G" 40 PCK/0A PCK30/A PCK30/0A PCK40/A G" G" G" G /4" PCK- PCK inch inch inch 40 4 PCK40/0A G /4" 9 PCK PCK0/A PCK0/0A PCK60/A PCK60/0A PCK/A G /4" G /4" PCK60- PCK00 PCD-00 PCD PCK/0A PCD PCK00/A PCK00/A PCG00-0 PCG Technical Data of PCD Series () PCG kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCD/A PCD00/A PCD0/A PCD0/0A PCD0/A G /" PCD0/0A G /" 0 PCD0/A G /" 30 PCD0/0A G /" 300 PCD340/A DN0 00 Technical Data of PCG Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCG00/0A PCG0/A G /" 300 PCG0/0A G /" PCG0/A PCG0/0A PCG340/0A DN0 DN0 DN Voltages of 30V/V/400V and 60HZ are available. /

8 Technical Data of PCK Series () PCK/A-A PCK/0A-A PCK/A-A PCK/0A-A PCK0/A-A kw.. Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) 6 HZ/Phase/ Voltage Dimension G" Weight PCK- PCK0-30 PCK inch inch inch 40 4 PCK0/0A-A G" PCK PCK/A-A PCK/0A-A PCK30/A-A PCK30/0A-A PCK40/A-A G" G" G" G" G /4" PCK00 PCD-00 PCD0-0 PCD PCK40/0A-A G /4" 9 PCG PCK0/A-A G /4" 0 PCG PCK0/0A-A PCK60/A-A G /4" 40 PCG PCK60/0A-A PCK/A-A PCK/0A-A PCK00/A-A PCK00/A-A Technical Data of PCD Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCD/A-A PCD00/A-A PCD0/A-A PCD0/0A-A PCD0/A-A G /" PCD0/0A-A G /" 0 PCD0/A-A G /" 30 PCD0/0A-A G /" 300 PCD340/A-A DN0 00 Technical Data of PCG Series () kw Capacity (FAD) l/s m³min cfm Maximum working bar psig Noise level db(a) HZ/Phase/ Voltage Dimension Weight PCG00/0A-A PCG0/A-A G /" 300 PCG0/0A-A G /" PCG0/A-A PCG0/0A-A PCG340/0A-A DN0 DN0 DN Voltages of 30V/V/400V and 60HZ are available. 3/4

9 POWERLINK L Series Air Compressors VSD (variable speed driving) air compressors: alter the motor s rotate speed by changing frequency, the airflow can therefore be regulated. POWERLINK L Series Air Compressors With years permanent magnet technology, the motor and compressor air end utilize built-in gearless direct structure, which makes the machine more compact and ensures 00% transmission efficiency; Acquire 6 patents; Energy-efficient Features Working conditions: permanent magnet motor ensures very high efficiency even if the speed is low and air consumption is small. Save energy consumption when unloading the system (variable frequency and energy-saving). Save the wasted energy consumption when controlling bandwidth (variable frequency and energy-saving). Save energy consumption when starting the machine (variable frequency and energy-saving). Technical Advantages Motor Efficiency (%) Efficiency Comparation Motor Speed (rpm) Small in size: the size of the motor is about one third of that of normal frequency modulation motors, and the small size makes the machine easy to assembly and disassembly. Stable performance: permanent magnet High-Efficiency PM Motor New Screw Rotor High-end software design Simple structure greatly facilitates repair and maintenance Perfect combination between frequency converting control and permanent magnetic screw driving synchronous motors adopt superior Nd-Fe-B magnets which would not lose magnetic force even under 0 and have more than years service life; Stator coil utilizes corona resistant enameled wires that are specialized for inverters use only; the wires are characterized by excellent insulation performance and long service life. Distinction between POWERLINK TRL Series VSD Screw Compressors and Power Frequency Screw Compressors More stable air Shock-free when start-up Variable airflow control Cover Shaft Stator core Rotor core Magnet Coil Better voltage adaptability for AC supply Lower noise level /6

10 Technical Data of L Series () Technical Data of L Series () Rated bar psig Rated airflow rate m³min cfm kw Airend model (integrated permanent magnet motor and compressor) Max. RPM Oil seperator standard HZ/Phase /Voltage Rated bar psig Rated airflow rate m³min cfm kw Airend model (integrated permanent magnet motor and compressor) Max. RPM Oil seperator standard HZ/Phase /Voltage PCF/A TRLPM-. PCF/A-A TRLPM-. PCF/A TRLPM-. PCF/A-A TRLPM-. PCF30/0A TRLPM- PCF30/0A-A TRLPM- PCF30/3A TRLPM- PCF30/3A-A TRLPM- PCF0/A TRL0PM-3 PCF0/A-A TRL0PM-3 PCF0/A PCF60/0A PCF60/3A PCFD/A TRL0PM-3 TRL0PM- TRL0PM- TRLPM-. Gearless direct PCF0/A-A PCF60/0A-A PCF60/3A-A PCFD/A-A TRL0PM-3 TRL0PM- TRL0PM- TRLPM-. Gearless direct PCFD/A TRLPM-. PCFD/A-A TRLPM-. PCFD30/0A TRLPM- PCFD30/0A-A TRLPM- PCFD30/3A TRLPM- PCFD30/3A-A TRLPM- PCFD0/A TRL0PM-3 PCFD0/A-A TRL0PM-3 PCFD0/A TRL0PM-3 PCFD0/A-A TRL0PM-3 PCFD60/0A TRL0PM- PCFD60/0A-A TRL0PM- PCFD60/3A TRL0PM- PCFD60/3A-A TRL0PM-. The air displacement is caculated based on compressor suction condition (30 ).. The temperature of air outlet dew point is 30 and 0.69MPa. 3. The discharge is caculated in front of the one-way valve. 4. Motor service factor is SF=... The above permanent magnet motors meet energy efficiency level, vessel standard. 6. Meet JB/ , design and installation meet ISO 3 (also 09) standards, airflow rate test is in conformity with /T4, test meets safety requirements of ISO (also /33): JB 4-99 (also B 9.-9).. Voltages of 30V/V/400V and 60HZ are available.. The air displacement is caculated based on compressor suction condition (30 ).. The temperature of air outlet dew point is 30 and 0.69MPa. 3. The discharge is caculated in front of the one-way valve. 4. Motor service factor is SF=... The above permanent magnet motors meet energy efficiency level, vessel standard. 6. Meet JB/ , design and installation meet ISO 3 (also 09) standards, airflow rate test is in conformity with /T4, test meets safety requirements of ISO (also /33): JB 4-99 (also B 9.-9).. Voltages of 30V/V/400V and 60HZ are available. /

11 Aftertreatment Equipment Air Dryer Technical Data Air dryer AD0L Air process volume m³min 0.6 Work bar 0bar Voltage Phase/0V/0HZ dimension G½ Net weight Net weight Size Excellent design ensures high efficiency, low consumption, long lifetime; Real time operation parameters display; AD0M ADL ADM ADL bar 0bar 0 3bar 0bar Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ G½ G G G Easy operation and cost-effective. ADM AD3L. 0 3bar 0bar Phase/0V/0HZ Phase/0V/0HZ G G Precision filters AD3M AD0L 0 3bar 0bar Phase/0V/0HZ Phase/0V/0HZ G G½ Four class filter Q, P, S, C, meet various filtration needs; High filtration precision, easy maintenance and change; AD0M AD0L AD0M ADL ADM bar 0bar 0 3bar 0bar 0 3bar Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ Phase/0V/0HZ G½ G½ G½ Long service life. AD0L AD0M bar 0 3bar 3Phase/300V/0HZ 3Phase/300V/0HZ Air receiver Standard vessel for safe use; AD30L AD30M AD60L.. 6 0bar 0 3bar 0bar 3Phase/300V/0HZ 3Phase/300V/0HZ 3Phase/300V/0HZ Multiple models of volume and ; Quality product with cost-effective. AD60M AD0L AD0M 6 0 3bar 0bar 0 3bar 3Phase/300V/0HZ 3Phase/300V/0HZ 3Phase/300V/0HZ AD0L 6. 0bar 3Phase/300V/0HZ DN AD30L 3 0bar 3Phase/300V/0HZ DN AD430L 43. 0bar 3Phase/300V/0HZ DN Also adapt to other voltage or frequency. 9/0

12 Precision Filters Specification (Class Q) Precision filters specification (Class P) Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element AF0LQ 0.6 0bar G AF0LP 0.6 0bar μm ppm G AF0MQ bar G AF0MP bar μm ppm G AFLQ. 0bar G AFLP. 0bar μm ppm G AFMQ. 0 3bar G AFMP. 0 3bar μm ppm G AFLQ. 0bar G AFLP. 0bar μm ppm G AFMQ. 0 3bar G AFMP. 0 3bar μm ppm G AF3LQ 0bar G AF3LP 0bar μm ppm G AF3MQ 0 3bar G AF3MP 0 3bar μm ppm G AF0LQ 0bar G½ 3 63 AF0LP 0bar μm ppm G½ 3 63 AF0MQ 0 3bar G½ 3 63 AF0MP 0 3bar μm ppm G½ 3 63 AF0LQ 6. 0bar G½ 3 63 AF0LP 6. 0bar μm ppm G½ 3 63 AF0MQ bar G½ 3 63 AF0MP bar μm ppm G½ 3 63 AFLQ. 0bar 3 63 AFLP. 0bar μm ppm 3 63 AFMQ. 0 3bar 3 63 AFMP. 0 3bar μm ppm 3 63 AF0LQ 0.9 0bar 3 63 AF0LP 0.9 0bar μm ppm 3 63 AF0MQ bar 3 63 AF0MP bar μm ppm 3 63 AF30LQ. 0bar 3 63 AF30LP. 0bar μm ppm 3 63 AF30MQ. 0 3bar 3 63 AF30MP. 0 3bar μm ppm 3 63 AF60LQ 6 0bar φ9 399 AF60LP 6 0bar μm ppm φ9 399 AF60MQ 6 0 3bar φ9 399 AF60MP 6 0 3bar μm ppm φ9 399 AF0LQ 0bar φ AF0LP 0bar μm ppm φ AF0MQ 0 3bar φ AF0MP 0 3bar μm ppm φ AF0LQ 6. 0bar DN0 6 φ AF0LP 6. 0bar μm ppm DN0 6 φ AF30LQ 3 0bar DN0 φ9 9 9 AF30LP 3 0bar μm ppm DN0 φ9 9 9 AF430LQ 43. 0bar DN0 φ AF430LP 43. 0bar μm ppm DN0 φ Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice.. Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice. /

13 Precision filters specification (Class S) Precision filters specification (Class C) Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element Air flow Work m³min bar Filter fineness Oil content dimension Net weight Size Qty of element AF0LS 0.6 0bar 0.0μm 0.0ppm G AF0LC 0.6 0bar 0.0μm G AF0MS bar 0.0μm 0.0ppm G AF0MC bar 0.0μm G AFLS. 0bar 0.0μm 0.0ppm G AFLC. 0bar 0.0μm G AFMS. 0 3bar 0.0μm 0.0ppm G AFMC. 0 3bar 0.0μm G AFLS. 0bar 0.0μm 0.0ppm G AFLC. 0bar 0.0μm G AFMS. 0 3bar 0.0μm 0.0ppm G AFMC. 0 3bar 0.0μm G AF3LS 0bar 0.0μm 0.0ppm G AF3LC 0bar 0.0μm G AF3MS 0 3bar 0.0μm 0.0ppm G AF3MC 0 3bar 0.0μm G AF0LS 0bar 0.0μm 0.0ppm G½ 3 63 AF0LC 0bar 0.0μm G½ 3 63 AF0MS 0 3bar 0.0μm 0.0ppm G½ 3 63 AF0MC 0 3bar 0.0μm G½ 3 63 AF0LS 6. 0bar 0.0μm 0.0ppm G½ 3 63 AF0LC 6. 0bar 0.0μm G½ 3 63 AF0MS bar 0.0μm 0.0ppm G½ 3 63 AF0MC bar 0.0μm G½ 3 63 AFLS. 0bar 0.0μm 0.0ppm 3 63 AFLC. 0bar 0.0μm 3 63 AFMS. 0 3bar 0.0μm 0.0ppm 3 63 AFMC. 0 3bar 0.0μm 3 63 AF0LS 0.9 0bar 0.0μm 0.0ppm 3 63 AF0LC 0.9 0bar 0.0μm 3 63 AF0MS bar 0.0μm 0.0ppm 3 63 AF0MC bar 0.0μm 3 63 AF30LS. 0bar 0.0μm 0.0ppm 3 63 AF30LC. 0bar 0.0μm 3 63 AF30MS. 0 3bar 0.0μm 0.0ppm 3 63 AF30MC. 0 3bar 0.0μm 3 63 AF60LS 6 0bar 0.0μm 0.0ppm φ9 399 AF60LC 6 0bar 0.0μm φ9 399 AF60MS 6 0 3bar 0.0μm 0.0ppm φ9 399 AF60MC 6 0 3bar 0.0μm φ9 399 AF0LS 0bar 0.0μm 0.0ppm φ AF0LC 0bar 0.0μm φ AF0MS 0 3bar 0.0μm 0.0ppm φ AF0MC 0 3bar 0.0μm φ AF0LS 6. 0bar 0.0μm 0.0ppm DN0 6 φ AF0LC 6. 0bar 0.0μm DN0 6 φ AF30LS 3 0bar 0.0μm 0.0ppm DN0 φ9 9 9 AF30LC 3 0bar 0.0μm DN0 φ9 9 9 AF430LS 43. 0bar 0.0μm 0.0ppm DN0 φ AF430LC 43. 0bar 0.0μm DN0 φ Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice.. Special specifications accept customization. Other flow filter inquiries welcomed.. The specification and detail are subject to change without prior notice. 3/4

14 Air Receiver Technical Data Specification Work Total height Inner diameter φ bar dimension Net weight AT06L() 0.6m³/.0Mpa 0bar AT06M() 0.6m³/.3Mpa 0 3bar AT0L().0m³/.0Mpa 0bar AT0M().0m³/.3Mpa 0 3bar AT0L().0m³/.0Mpa 0bar DN0 6 AT0M().0m³/.3Mpa 0 3bar DN0 6 AT30L() 3.0m³/.0Mpa 0bar DN0 9 AT30M() 3.0m³/.3Mpa 0 3bar DN0 9 AT40L() 4.0m³/.0Mpa 0bar DN00 AT40M() 4.0m³/.3Mpa 0 3bar DN00 AT0L().0m³/.0Mpa 0bar DN00 6 AT0M().0m³/.3Mpa 0 3bar DN00 6 AT06L() C 0.6/.0 0bar AT06M() C 0.6/.3 0 3bar AT0L() C.0/.0 0bar AT0M() C.0/.3 0 3bar AT0L() C.0/.0 0bar DN0 6 AT0M() C.0/.3 0 3bar DN0 6 AT30L() C 3.0/.0 0bar DN0 9 AT30M() C 3.0/.3 0 3bar DN0 9 AT40L() C 4.0/.0 0bar DN00 AT40M() C 4.0/.3 0 3bar DN00 AT0L() C.0/.0 0bar DN00 6 AT0M() C.0/.3 0 3bar DN00 6. The specification and detail are subject to change without prior notice. /6

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling IBM Symposium 2008 Data Center Cooling EC Systems for HVAC architecture and Direct air Cabinet Cooling Presented by David J. Spofford Product Manager IT/Telecomm 1 Agenda Data Center trends for IT and

More information

Performance and Efficiency

Performance and Efficiency 01 GB Performance and Efficiency Compressed air management system Superior control solutions SmartAir Master Efficiency. Performance. Monitoring. Great energy saving potential Energy management is crucial

More information

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP) High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes

More information

Ver.1.1. subject to be changed without prior notice

Ver.1.1. subject to be changed without prior notice Ver.1.1 subject to be changed without prior notice SMT EUROPE 1. SMT LINE Configuration (External PSA) 8 1 2 3 4 5 6 7 9 N70-e Series Reflow Is developed to realize ultra low energy consumption following

More information

Compressor Controller MAM 890

Compressor Controller MAM 890 Compressor Controller MAM 890 OPERATION MANUAL Revision 1.0 04.08.2017 Notice Please read all the operation manual before operating the set and keep this manual for further reference. Installation of MAM

More information

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear

DDDM 45 (40-60 TPH) DDDM 60 ( TPH) COLD AGGREGATE FEEDER. Auxiliary belt No. of bins. Gathering conveyor reduction gear I TECHNICAL SPECIFICATIONS ROAD BUILDING DDDM 45 (40-60 TPH) DOUBLE DRUM ASPHALT PLANT - DDDM 50 (60-90 TPH) DDDM 60 (90-120 TPH) COLD AGGREGATE FEEDER Stationary four bin cold aggregate feeder unit is

More information

Digital Overhead Stirrer

Digital Overhead Stirrer A Geno Technology, Inc. (USA) brand name Digital Overhead Stirrer Cat. No. BT1021 1-800-628-7730 1-314-991-6034 info@btlabsystems.com Thanks for choosing BT1021 Digital Overhead Stirrer. This operation

More information

Oil Free Scroll. Air Compressors

Oil Free Scroll. Air Compressors Oil Free Scroll Air Compressors History of HITACHI Air Technology 1910 1930 1950 1970 1980 1911: 75kW Reciprocating First Compressor in Japan 1977: Smallest 5.5kW Oil Injected Rotary Screw 1976: Oil Injected

More information

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive ICON SERIES IDRIVE Intelligent Constant Pressure Water Supply Controller User Manual idrive1150-240 CONTENTS PREFACE 3 1. PRODUCT DESCRIPTION 4 1.1 Functions Description 4 1.2 Model List 4 1.3 Nameplate

More information

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity

HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT. Min. Circuit Ampacity ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) Product Specifications HIGH EFFICIENCY 15 and 17 TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208 / 230 Volt,

More information

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control APPLICATIONS FEATURES Flood control Irrigation Land drainage Pollution control Industry Water refineries Water parks Design OPERATING DATA Capacity:...up to.000 m/h Head:...up to m Max. water temperature:...0

More information

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw IT COOLING CLOSE CONTROL AIR CONDITIONERS CHILLED WATER HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw 3 Versions available Single chilled water coil Double chilled water coil High temperature IT COOLING

More information

U-Match Series DC Inverter Service Manual PRODUCT

U-Match Series DC Inverter Service Manual PRODUCT PRODUCT 1 PRODUCT 1 MODELS LIST 1.1 Outdoor Unit Name Product Code Power Supply (V, Ph, Hz) Appearance GUHD24NS3GO CF090W0800 220-240V~ 50/60Hz GUHD36NS3GO CF090W0860 220-240V~ 50/60Hz GUHD42NS3GO CF090W0870

More information

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...)

Electromotoric actuators Torques up to 60 Nm Running times ¹) s. ¹) Predefined by the basic unit (LMV5...) 7 818 Actuators SQM9... Electromotoric actuators Torques up to 60 Nm Running times ¹) 30...120 s ¹) Predefined by the basic unit (LMV5...) The SQM9... and this Data Sheet are intended for use by OEMs which

More information

ES 4000 STANDARD. 1 General information Document Overview General description Introduction... 4

ES 4000 STANDARD. 1 General information Document Overview General description Introduction... 4 Controller Instruction 1 General information ES 4000 STANDARD Printed Matter Number : 2946 7002 09 Applicable to : MB compressors Preliminary Operations: : Safety Instructions : General Persons Required

More information

Slim duct (AMTTTFNLDEH ) Indoor units

Slim duct (AMTTTFNLDEH ) Indoor units Slim duct (AMTTTFNLDEH ) Slim duct. Specifications 1) Technical specifications Model AM22FNLDEH AM28FNLDEH AMFNLDEH AM4FNLDEH AMFNLDEH Power Supply Ø, #, V, Hz 1,2,22-24, 1,2,22-24, 1,2,22-24, 1,2,22-24,

More information

CFM-9225V XX - CXX

CFM-9225V XX - CXX date 7/1/217 page 1 of 1 SERIES: CFM-2V DESCRIPTION: DC AXIAL FAN FEATURES omnicool TM bearing system 2 x 2 mm frame multiple speed options for different cooling needs tachometer signal and rotation detect

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money SmartAir Master The intelligent compressed air management system Developed by Compair to save your customers money Customers will need more Energy Efficient Systems Why do we make more energy efficient

More information

Model QRS CPVS

Model QRS CPVS SPARE PARTS LIST EN CP COMPRESSOR Model QRS 0-5 - 0 CPVS 0-5 - 0 6 05 50 65 KEY - Door Panel: 655900 Lock - Door Panel: 005076 QRS 0 CONTENTS Title Page MAINTENANCE HOW TO READ THIS SPARE PART LIST? KIT

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILA1F572PB1A0 integrated drive ILA with servo motor V - CANopen - PCB connector Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

The Rogers QNW HP Series is a state-of-the-art, high pressure compressor for service applications requiring high pressure.

The Rogers QNW HP Series is a state-of-the-art, high pressure compressor for service applications requiring high pressure. The Rogers QNW HP Series is a state-of-the-art, high pressure compressor for service applications requiring high pressure. www.rogers-machinery.com Inside the QNW HP Series When your production requirements

More information

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller

Pocket Quick. Reference Guide. On the TOSHIBA RBC-AMS51E. Remote Controller Pocket Quick Reference Guide On the TOSHIBA RBC-AMS51E Remote Controller Quick Reference Guide To assist service engineers working on Toshiba air conditioning equipment, there is a large quantity of data

More information

07. har-link Interface Connectors

07. har-link Interface Connectors . Interface Connectors The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications Product Information ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications January 2009 ECN 1023/EQN 1035 Series Rotary encoders for safety-related applications With integral

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

Provided services catalogue

Provided services catalogue «Provided Services» Provided services catalogue 1. Condition monitoring services (vibration analysis, ultra-sound analysis) on rotating equipment. 2. On-site dynamic balancing of impellers. 3. High precision

More information

Voltage Current Front-mounting bracket

Voltage Current Front-mounting bracket Switching Power Supply S8PS Compact DIN-Rail Mounting Industrial Power Supplies with Capacities Up to 600 W Models range from 0 W to 600 W. Universal input: voltage range 0 to 240 VAC. Power Factor Correction

More information

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW. CENTRIFLOW PUR 3D (A, PLUG B, C, D) FAN GMPM FC101 AND SLIDE IN FREQUENCY ROTOR CASSETTE CONVERTER QUICK GUIDE FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS

More information

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 60 W Main Range of product Product or component type Power supply type Rated power in W Input voltage Output voltage Power

More information

Shenzhen VTdrive Technology Co.,Ltd.

Shenzhen VTdrive Technology Co.,Ltd. V&T INVERTER PRODUCT CATALOGUE Development from Accumulation,Achievement from Innovation Following Tide of the World,Forging Paradigm of Industry English Version:VX 20111018 H 1.0 BOM:37110050 print for

More information

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply Switching Power Supply Compact and Economical Switching Power Supply Models range from 10 to 50 W Open-frame and covered types Wide range of output voltage: 5-, 12-, 15- and 24-V models UL, CSA approved

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution

Stainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution Stainless Steel Submersible Pumps DATA BOOKET ISO Company Pumping Solution Hz Photographs of a few Manufacturing Units Contents Stainless steel submersible bore well pumps Product data Introduction Operating

More information

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI NOVOTURN Multiturn-Sensor non-contacting Series RSM2800 digital SSI, SPI Special features True Power On System: counts turns even when not powered. Patented non-volatile technology does not require gears

More information

Manual Vibration Meter PCE-VT PCE Instruments

Manual Vibration Meter PCE-VT PCE Instruments Manual Vibration Meter PCE-VT 2700 EN PCE Instruments Thank you for purchasing a vibration meter PCE-VT2700 from PCE Instruments. This vibration meter is perfectly suitable for maintenance as it tests

More information

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

Motor Controllers. On-Road AC Motor Controller. Model 1239E.

Motor Controllers. On-Road AC Motor Controller. Model 1239E. Motor Controllers Model 29E www.curtisinstruments.com The E difference A significant enhancement to the Curtis AC family, The E models utilize a powerful dual-microprocessor logic architecture to provide

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015

ESC 201. Installation and Operating Instructions Manual. SG Jan 2015 ESC 201 Installation and Operating Instructions Manual SG-0002-03 Jan 2015 Table of Contents 1.0 FUNCTIONS... 5 2.0 FEATURES... 5 3.0 ESC 201 DESCRIPTION... 6 4.0 GENERAL OPERATIONS... 6 4.1 MANUAL MODE

More information

Easy interface A large monitor, comprehensible interface allow getting any information required, or setting up the control system.

Easy interface A large monitor, comprehensible interface allow getting any information required, or setting up the control system. of new generation are intended for hand-operated, automatic and remote monitoring, control and protection of the ESP systems, equipped with asynchronous or ac motors, rated capacity up to 320 kw. ALSU

More information

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W Characteristics regulated SMPS - single phase - 100..240 V input - 24 V output - 240 W Complementary Input voltage limits Network frequency limits Inrush current Main Range of product Product or component

More information

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU

SINGLE. Technical Data Book. Big Duct for EU (R410A, 50Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU SINGLE Technical Data Book Big Duct for EU (R4A, 0Hz, HP) Model : IDU : AC***KNHPKH/EU ODU : AC***KXAPNH/EU History Version Modification Date Remark Ver 1.0 Release SINGLE Big Duct for EU (R4A, 0Hz, HP)

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

QLC(Y) SERIES EMERGENCY FIRE FIGHTING WATER SUPPLY EQUIPMENT

QLC(Y) SERIES EMERGENCY FIRE FIGHTING WATER SUPPLY EQUIPMENT As we are constantly endeavouring to improve the performance of our equipment. The company reserves the right to make alteration from time to time and equipment differ from that detailed in this brochure.

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

W Economic: Can be installed quickly and efficiently. W Compact and versatile: Top technology for limited

W Economic: Can be installed quickly and efficiently. W Compact and versatile: Top technology for limited Incremental and Absolute Encoders especially for Drive Technology RoHS 2/22 Complete Solutions for geared motors W Sturdy: Withstands even the toughest conditions. W Economic: Can be installed quickly

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/ V(7.5kW) Product datasheet Characteristics ATS22D17Q soft starter-ats22-control 220V-power 230V (4kW)/400...440V(7.5kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

Gardner Denver / Tamrotor Enduro 12 Rotary Screw Compressor, with Adaptable Compressor Speed, designed to produce more gas flow per bhp.

Gardner Denver / Tamrotor Enduro 12 Rotary Screw Compressor, with Adaptable Compressor Speed, designed to produce more gas flow per bhp. Technical Specifications Compressor Gardner Denver / Tamrotor Enduro 12 Rotary, with Adaptable Compressor Speed, designed to produce more gas flow per bhp. Engine Cummins G5.9, 6 cylinder natural gas engine.

More information

External level devices for conductive point level switch

External level devices for conductive point level switch SENSORS FOR FOOD AND BIOPHARMA. Product Information VNV-2, ZNV-2 CONTROLS External level devices for conductive point level switch Application/Specified usage Point level detection of aqueous, conductive

More information

MAJOR VA Power Inverter

MAJOR VA Power Inverter MAJOR500-500 VA Power Inverter The Major500 is a highly reliable, telecom quality, DC to AC power inverter. The Major500 features full electronic protection, high efficiency and low output noise. The built-in

More information

Reliability and extended operation

Reliability and extended operation CLIMAVENETA TELECOMSOLUTIONS Units for mobile telecounication applications, with free cooling and full DC Inverter technology. 1,5 20. Low operational and maintenance costs Wide range of full inverter

More information

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書 Read and save these insturctions 2008 Antari Lighting & Effects Ltd. User Manual Antari DNG-200 Low fog Generator Congratulations on the purchase

More information

POWERLINK Motor Test (Eddy Current Dynamometer)

POWERLINK Motor Test (Eddy Current Dynamometer) POWERLINK Motor Test (Eddy Current Dynamometer) info@powerlinkpt.com POWERLINK Motor Performance Test (Eddy Current Dynamometer) POWERLINK Motor Test (Eddy Current Dynamometer) KEY FEATURES High precision

More information

MINIMAT-EC-Servo Screwdriver handheld

MINIMAT-EC-Servo Screwdriver handheld Screwdriving Technology Automation Air Motors Air Tools MINIMAT-EC-Servo Screwdriver handheld straight handle design - torque ranges between 0.01-2.0 Nm The flexible EC-Servo screwdriver for low torque

More information

Asynchronous motors. 5/48 Permissible combinations of mechanical designs for 1PL6 motors,

Asynchronous motors. 5/48 Permissible combinations of mechanical designs for 1PL6 motors, Asynchronous motors 5 Asynchronous motors 5/2 Type overview and rated data 5/4 Technical definitions 5/4 Encoder systems 5/5 1PH7 motors 5/5 1PH7 motors, forced ventilation 5/32 Permissible combinations

More information

Gardner Denver / Tamrotor Enduro 25 Rotary Screw Compressor, with Adaptable Compressor Speed, designed to produce more gas flow per bhp.

Gardner Denver / Tamrotor Enduro 25 Rotary Screw Compressor, with Adaptable Compressor Speed, designed to produce more gas flow per bhp. Technical Specifications Compressor Gardner Denver / Tamrotor Enduro 25 Rotary, with Adaptable Compressor Speed, designed to produce more gas flow per bhp. Engine Cummins G8.3, 6 cylinder natural gas engine.

More information

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are

More information

CFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000Pa Filter area: m²

CFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000Pa Filter area: m² CFL filters Complete and space-saving Plug & Play compressed-air cleaned filter unit with integrated fan to be used for air filtration from processes that form limited dust volumes (welding, cutting, grinding

More information

Unique Compressed Air Management System. GD Connect 12. The perfect fit

Unique Compressed Air Management System. GD Connect 12. The perfect fit Unique Compressed Air Management System GD Connect 12 The perfect fit State-of-the-art Technology Advanced Microprocessor Technology Safe and fast exchange of large amounts of data is ensured by large

More information

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured

More information

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW) Characteristics soft starter-ats22-control 220V-power 230V(4kW)/400...440V(7.5kW) Main Range of product Altistart 22 Product or component type Product destination Product specific application Component

More information

DATA SHEET. L1210/65/68 Tray loaders incorporating VAM1202/12 mechanism for 2x Speed. Philips Optical Storage. Philips Components

DATA SHEET. L1210/65/68 Tray loaders incorporating VAM1202/12 mechanism for 2x Speed. Philips Optical Storage. Philips Components DATA SHEET Tray loaders incorporating VAM1202/12 mechanism for 2x Speed Product specification MAY 2000 Version 1.0 Philips Components SCOPE OF THIS DOCUMENT This document describes the Commercial specification

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

2 Telecommunications Data Center Facility Requirements

2 Telecommunications Data Center Facility Requirements Generic Requirements for Telecommunications Data Center Equipment and Spaces GR-3160-CORE Table of Contents Table of Contents Generic Requirements Notice of Disclaimer..................... iii Preface...........................................

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline

More information

Removal and Installation8

Removal and Installation8 8 Screw Types 8-4 Top Cover Assembly 8-5 Left Hand Cover 8-6 Right Hand Cover 8-10 Front Panel Assembly 8-14 Left Rear Cover 8-15 Right Rear Cover 8-16 Extension Cover (60" Model only) 8-17 Media Lever

More information

Laserline LDM The compact class for diode laser

Laserline LDM The compact class for diode laser Laserline LDM The compact class for diode laser Compact, Powerful and Reliable in any Application Compact The 19-inch rack mount technology offers a significant simplification of the laser integration

More information

Provisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Provisional Product Information. ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications Provisional Product Information ECN 1123 EQN 1135 Rotary Encoders with EnDat 2.2 for Safety-Related Applications November 2007 ECN 1123/EQN 1135 Series Rotary encoders for safety-related applications With

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Intelligent vibration monitoring.

Intelligent vibration monitoring. Intelligent vibration monitoring. Diagnostic systems www.ifm.com/gb/octavis fluid sensors and diagnostic systems position sensors and object recognition bus, identification and control systems For industrial

More information

Matsushita. VF-C Compact. Inverter NEW: - Ultra-compact - Latest technology - Cost effective. Configurator software Motion Control Ver.1.

Matsushita. VF-C Compact. Inverter NEW: - Ultra-compact - Latest technology - Cost effective. Configurator software Motion Control Ver.1. Matsushita NEW: Configurator software Motion Control Ver.1.3 VF-C Compact Inverter - Ultra-compact - Latest technology - Cost effective VF-C inverter - a new generation for the 0.25 kw to 4.0 kw power

More information

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours! Data sheet MK 20 GR Customized solution or off-the-shelf: The choice is yours! MK20-GR data sheet Looking for a quick and reliable solution? Then rely on our standard products: Our universal controls provide

More information

07. har-link INTERFACE CONNECTORS

07. har-link INTERFACE CONNECTORS . INTERFACE CONNECTORS The highest data rates in combination with perfect shielding characterize the connector. This way data can be passed on optimally within the control cabinet. The locking mechanism

More information

List of forms CLAP/WGP by subject /68/UE

List of forms CLAP/WGP by subject /68/UE List of forms CLAP/WGP by subject - 2014/68/UE Subject Assembly - Assembly including an item of pressure equipment placed on the market before 29 May 2002 in compliance with national pre-ped regulations

More information

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24,

Min. Circuit Ampacity. Max. Fuse or Breaker. Ship / Operating Weight lbs. (kg) C4H524GKD 2 24, ENVIRONMENTALLY SOUND REFRIGERANT C4H(5, 7) SXT+ Product Specifications HIGH EFFICIENCY 15 and 17 SEER TWO STAGE HEAT PUMP ENVIRONMENTALLY SOUND R 410A REFRIGERANT 2, 3, 4, and 5 TONS SPLIT SYSTEM 208

More information

IDS 500 mobile Intelligent mobile chart recorder

IDS 500 mobile Intelligent mobile chart recorder IDS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

8 Submersible Motors Standard

8 Submersible Motors Standard Applications These motors are built for dependable operation in vertical 8 diameter or larger water wells. Basic Features Double Flanged NEMA mounting design Stainless steel splined shaft StatorShield

More information

PFC Mini TM Power Factor Corrected AC-DC Switchers

PFC Mini TM Power Factor Corrected AC-DC Switchers 21 PFC Mini TM Power Factor Corrected AC-DC Switchers Overview Technical Description The PFC Mini is an extremely low profile switching power supply that combines the advantages of power factor correction,

More information

Thin clients JC500X - 1 Reference guide

Thin clients JC500X - 1 Reference guide Thin clients JC500X - 1 Reference guide 1. Product introduction 1-1 product overview Using Intel N2840 BayTrail dual-core embedded processor ( or Intel J2900), low power consumption new fashionable appearance,

More information

DATA SHEET Compact Genset Controller, CGC 200

DATA SHEET Compact Genset Controller, CGC 200 DATA SHEET Compact Genset Controller, CGC 200 Auto start and parameter monitoring Warnings and shutdown protections Includes 5 digital inputs, 5 relay outputs Configurable for other applications Licence-free

More information

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Keor HPE UPS THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES LEGRAND UPS SERVICE continuity ENERGY efficiency SUPERIOR PERFORMANCES Legrand, world

More information

Tel: AC Power for Business-Critical Continuity TM

Tel: AC Power for Business-Critical Continuity TM Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications Product Information ROC 425 ROQ 437 Absolute Rotary Encoders with EnDat 2.2 for Safety-Related Applications 10/2016 ROC 425, ROQ 437 with synchro flange Rotary encoders for absolute position values with

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

Rotary Measuring Technology

Rotary Measuring Technology Multiturn Type 8 Profibus-DP Very compact (only 87.8 mm installation depth); Ideal for dynamic applications thanks to its non-contact multiturn stage Solid shaft or blind hollow shaft Long service life

More information

PRODUCT FEATURES AND ADVANTAGES

PRODUCT FEATURES AND ADVANTAGES Flatpack2 24/1800 HE 24VDC Rectifier/Converter Modules The combination of innovative design, efficiency and reliability makes the Flatpack2 HE stand out. With efficiency up to 96.2%, the losses have been

More information

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input

(877) CPCI-3U Series. Input Voltage Range AC Input. Input Voltage Range 48VDC Input. Input Voltage Range 24/28VDC Input (877) 634-0982 www.digipwr.com 200 300 Watt Compact PCI Power Supply Product Specification Universal AC Input with PFC, 48VDC or 24/28VDC Input Key Product Features Up to 3U Cabinet Environmentally Rugged

More information