QLC(Y) SERIES EMERGENCY FIRE FIGHTING WATER SUPPLY EQUIPMENT

Size: px
Start display at page:

Download "QLC(Y) SERIES EMERGENCY FIRE FIGHTING WATER SUPPLY EQUIPMENT"

Transcription

1 As we are constantly endeavouring to improve the performance of our equipment. The company reserves the right to make alteration from time to time and equipment differ from that detailed in this brochure. QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT -8 8 (08888 ( Address:-8 Cao'an Road, Jiangqiao Shanghai.C.: 8 Switchboard: ( Fax: ( Free consultation Tel: webmaster@lcpumps.com 08 roduct Catalog 08 The first printing of the 08 edition Date of printing th.oct.08 All rights reserved.irate is forbidden.

2 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT Outline meaning Structure principle selection erformance QLC(Y. GA0. QLC(Y QLC(Y series emergency fire fighting water supply equipment Mainly for the initial fire fighting water supply of 0- minutes for buildings, used as a high-positioned water tank for the places no way to set it and for such temporary buildings as available with fire fighting demand. Executed standard GA0. Fire fighting pneumatic water supply equipment About the product QLC(Y series fire fighting boosting & pressure stabilizing equipment consists of a water-supplementing pump, a pneumatic tank, an electric control cabinet, necessary valves, pipelines etc. Attachments. Usually two water pumps of an identical performance are set, with one used and one standby, and automatically work alternatively. In case of a failure with one of them, the other is put into use. The pneumatic tank, as the necessary link for the pressure keeping at the equipment stop, supplies water to and maintains the pressure for the fire fighting pipe-net, acts as a pressure switch and supplies 0-min water for the fire fighting system. The electric control cabinet is used to control starting/stopping the pump, realizing the automatic running control of the equipment. Figure and installing dimensions drawing Figure and installing dimensions table Use and maintenance Failures causes and troubleshooting QLC(Y QLC(Y QLC(Y QLC(Y QLC(Y Features of the product.qlc(y series fire fighting boosting & pressure stabilizing equipment is designed and made completely following the national and industrial standards..the parts used with QLC(Y series fire fighting boosting & pressure stabilizing equipment comply with the national and industrial standards and the key ones are the products of wellknown domestic and abroad brands..through continual improving and perfecting, QLC(Y series fire fighting boosting & pressure stabilizing equipment is made ripe in the technique, stable in the work and reliable in the performance..qlc(y series fire fighting boosting & pressure stabilizing equipment has a compact and reasonable structure and is flexible on the site arrangement and easily mountable and repairable..qlc(y series fire fighting boosting & pressure stabilizing equipment holds the alarming and self-protecting functions upon over-current, lack-of-phase, short-circuit etc. failures.

3 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT Q LC (Y / Fire-fighting of pump Effective water volume (m Fire-fighting working capacity (L/s Fire-fighting working pressure (Ma Emergency neumatic tank Liancheng product Fire fighting pneumatic water supply equipment Electric control cabinet To fire fighting pipe network 0 No Name Floating switch Fire fighting water pool (tank Electric joint pressure gauge (pressure control A A-A A Main water outlet pipe Butterfly valve (open-close Mounting valve (pressure discharge Flexible joint Check valve Shock isolating cushion ressure gauge (pressure readout neumatic tank Gate valve (open-close Butterfly valve (open-close Ball valve (sewage valve Usually both water-supplementing pump and pneumatic tank maintain the pressure of the fire fighting water supply pipe-net for the pressure loss caused by normal leak. When the pressure stabilizing pump works, it feeds water into the pipenet and, when the surplus water goes into the pneumatic tank, the water room gets expanded, the air-room gets shortened and the pressure gets raised. When the pressure of the pipe-net rises to the upper limit of the pressure stabilization, the water-supplementing pump stops working to enter the stopped and pressure-kept status and the stored water is fed into the pipe-net by the pressure of the compressed air inside of the pneumatic tank, then the water room gets shortened, the air room gets expanded and the pressure falls down therewith. When the pressure of the pipe-net lowers to the lower limit of the pressure stabilization, the water-supplementing pump restarts. In this repeated way, the water-supplementing pump continues working to make the pressure of the pipe-net kept in between both upper and lower limits of the pressure stabilization. In case of a fire, the hydrant or shower opens and the pressure of the pipe-net continues lowering, causing the work of the water-supplementing pump unable to meet with the requirement on the said pressure, the said pressure is then maintained and the ten-min emergency fire fighting water is supplied by the water pressed out of the pneumatic tank.

4 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT The water pump in the equipment is used as a watersupplementing pump (with the water-supplementing time decided by the pump's flow and required to meet with the flow of the water used for the pressure stabilization of the fire fighting pipe-net, therefore it is suggested use a water pump of a small flow as can as possible, provided that the water used for the pressure stabilization can be met with (so as to reduce the equipment's installation space and the manufacturing cost; the working pressure is estimated upon the desired static-water pressure in the most adverse point of the pipe-net, so select a water pump mostly closed to the performance point upon both working flow and pressure. QLC(Y0./.0- QLC(Y0./.- QLC(Y0.0/.0- QLC(Y0./- QLC(Y0./.0- (Ma =0.77 =0.7 =0. =0. =0.77 =0.7 =0. =0. =0.77 =0.7 =0. =0.0 =0.77 =0.7 =0. =0. =0.77 =0.7 =0. =0. specs GDL- 7 GDL- 7 GDL- 7 GDL- 7 GDL- 7 pressure (Ma flow (L/s..... ower (kw of pump specs ML00*.0 ML00*.0 ML00*.0 ML0*.0 ML000*.0 Total volume (m 8.. Effective water volume (m. of LEC - Ac - Decide the model of the pneumatic tank according to the ten-min fire fighting water quantity of a building, with the volume a little bit larger. Recommended model of the electric control cabinet: 7 8 QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.7/.0- =0.88 =0.8 =0. =0.8 =0.88 =0.8 =0. =0. =0.88 =0.8 =0. =0.7 GDL- 8 GDL- 8 GDL ML00*.0 ML00*.0 ML00* LEC - Ac - QLC(Y0./- =0.88 =0.8 =0. =0. GDL ML0*.0 ower of water pump and motor 0 QLC(Y0./.0- =0.88 =0.8 =0. =0. GDL ML000*.0 Y On-Off of the pressure controlled pump Changeover of automatic alternation Number of controlled pump Electric control cabinet brand of Liancheng Remark: the control cabinet can be floor or wall-hung type upon the user's requirement. See Structure for both valve and pipeline and, in case of special requirements (fire fighting water tank, main pipe of water inlet, Y-type filter, material requirement etc., please note it in the order contract. 7 QLC(Y0./.0- QLC(Y0./.- QLC(Y0./.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0./.0- QLC(Y0./.- =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =0. =.0 =.0 =.0 =0. =.0 =.0 =.0 =0. GDL- GDL- GDL- GDL- GDL- GDL- 0 GDL ML00*.0 ML00*.0 ML00*.0 ML0*.0 ML000*.0 ML00*. ML00* QLC(Y0./.0- =.0 =.0 =.0 =0. GDL- 0.. ML00*.. QLC(Y0./- =.0 =.0 =.0 =0. GDL- 0.. ML0*. QLC(Y0./.0- =.0 =.0 =.0 =0. GDL- 0.. ML000*. QLC(Y0./.0- =. =. =. =0.8 GDL-.. ML00*. 8. QLC(Y0./.- =. =. =. =0. GDL-.. ML00*.. QLC(Y0./.0- =. =. =. =0.8 GDL-.. ML00*.. QLC(Y0./- =. =. =. =0. GDL-.. ML0*. QLC(Y0./.0- =. =. =. =0. GDL-.. ML000*.

5 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT (Ma specs pressure (Ma flow (L/s ower (kw of pump Total Effective of ower of Effective specs volume water volume (Ma Total specs pressure flow water volume (kw pump specs volume (m (m (Ma (L/s (m (m of QLC(Y0.7/.0- =. =.7 =. =0.7 GDL-.. ML00*. 8. QLC(Y0.0/.0- =.08 =.0 =.00 =0.0 0GDL ML00* QLC(Y0.7/.- =. =.7 =. =0.7 GDL-.. ML00*.. QLC(Y0.8/.- =.08 =.0 =.00 =0.8 0GDL ML00* QLC(Y0.7/.0- =. =.7 =. =0.7 GDL-.. ML00*.. QLC(Y0.0/.0- =.08 =.0 =.00 =0.0 0GDL ML00*. 8. QLC(Y0.7/- =. =.7 =. =0.7 GDL-.. ML0*. QLC(Y0.8/- =.08 =.0 =.00 =0.8 0GDL ML00* QLC(Y0.7/.0- =. =.7 =. =0.7 GDL-.. ML000*. QLC(Y0.8/.0- =.08 =.0 =.00 =0.8 0GDL ML00*. 8. QLC(Y0.8/.0- =. =.8 =. =0.8 GDL-.. ML00*. 8. QLC(Y0.8/.0- =. =. =. =0.8 0GDL ML00*. 8. QLC(Y0.7/.- =. =.8 =. =0.7 GDL-.. ML00*.. 7 QLC(Y0./.- =. =. =. =0. 0GDL ML00*.. QLC(Y0.8/.0- =. =.8 =. =0.8 GDL-.. ML00*.. 8 QLC(Y0.8/.0- =. =. =. =0.8 0GDL ML00*.. QLC(Y0.7/- =. =.8 =. =0.7 GDL-.. ML0*. QLC(Y0./- =. =. =. =0. 0GDL ML0*. QLC(Y0.7/.0- =. =.8 =. =0.7 GDL-.. ML000*. 0 QLC(Y0./.0- =. =. =. =0. 0GDL ML000*. QLC(Y0.8/.0- =0.7 =0.7 =0. =0.8 0GDL ML00*.0 8. QLC(Y0.7/.0- =. =.7 =. =0.7 0GDL-..7 ML00* QLC(Y0./.- =0.7 =0.7 =0. =0. 0GDL ML00*.0. QLC(Y0.7/.- =. =.7 =. =0.7 0GDL-..7 ML00*.. 8 QLC(Y0.7/.0- =0.7 =0.7 =0. =0.7 0GDL ML00*.0. QLC(Y0.7/.0- =. =.7 =. =0.7 0GDL-..7 ML00*.. QLC(Y0./- =0.7 =0.7 =0. =0. 0GDL ML0*.0 QLC(Y0.7/- =. =.7 =. =0.7 0GDL-..7 ML0*. 0 QLC(Y0./.0- =0.7 =0.7 =0. =0. 0GDL ML000*.0 QLC(Y0.7/.0- =. =.7 =. =0.7 0GDL-..7 ML000*. QLC(Y0./.0- =0.8 =0.7 =0.7 =0. 0GDL ML00*.0 8. QLC(Y0.8/.0- =. =. =. =0.8 0GDL-..7 ML00*. 8. QLC(Y0./.- =0.8 =0.7 =0.7 =0. 0GDL ML00*.0. 7 QLC(Y0./.- =. =.7 =. =0. 0GDL-..7 ML00*.. QLC(Y0./.0- =0.8 =0.7 =0.7 =0. 0GDL ML00*.0. 8 QLC(Y0.8/.0- =. =.7 =. =0.8 0GDL-..7 ML00*.. QLC(Y0./- =0.8 =0.7 =0.7 =0. 0GDL ML0*.0 QLC(Y0./- =. =.7 =. =0. 0GDL-..7 ML0*. QLC(Y0./.0- =0.8 =0.7 =0.7 =0. 0GDL ML000*.0 70 QLC(Y0./.0- =. =.7 =. =0. 0GDL-..7 ML000*. QLC(Y0./.0- =0. =0. =0.88 =0. 0GDL ML00* QLC(Y0.0/.0- =0.0 =0. =0. =0.0 0GDL- 0.. ML00* QLC(Y0./.- =0. =0. =0.88 =0. 0GDL ML00*.0. 7 QLC(Y0./.- =0.0 =0. =0. =0. 0GDL- 0.. ML00*0.. 8 QLC(Y0./.0- =0. =0. =0.88 =0. 0GDL ML00*.0. 7 QLC(Y0.0/.0- =0.0 =0. =0. =0.0 0GDL- 0.. ML00*0.. QLC(Y0./- =0. =0. =0.88 =0. 0GDL ML0*.0 7 QLC(Y0./- =0.0 =0. =0. =0. 0GDL- 0.. ML0*0. 0 QLC(Y0./.0- =0. =0. =0.88 =0. 0GDL ML000*.0 7 QLC(Y0./.0- =0.0 =0. =0. =0. 0GDL- 0.. ML000*0.

6 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT (Ma specs pressure (Ma flow (L/s ower (kw of pump Total Effective of ower of Effective specs volume water volume (Ma Total specs pressure flow water volume (kw pump specs volume (m (m (Ma (L/s (m (m of 7 QLC(Y0.0/.0- =0.7 =0.70 =0.7 =0.0 0GDL ML00* QLC(Y0.8/.0- =.0 =. =. =0.8 0GDL- 0.. ML00* QLC(Y0.8/.- =0.7 =0.70 =0.7 =0.8 0GDL ML00*.0. 0 QLC(Y0.8/.- =.0 =. =. =0.8 0GDL- 0.. ML00*.. 78 QLC(Y0./.0- =0.7 =0.70 =0.7 =0. 0GDL ML00*.0. 0 QLC(Y0.8/.0- =.0 =. =. =0.8 0GDL- 0.. ML00*.. 7 QLC(Y0.8/- =0.7 =0.70 =0.7 =0.8 0GDL ML0*.0 0 QLC(Y0.8/- =.0 =. =. =0.8 0GDL- 0.. ML0*. QLC(Y0.8/.0- =0.7 =0.70 =0.7 =0.8 0GDL ML000*.0 0 QLC(Y0.8/.0- =.0 =. =. =0.8 0GDL- 0.. ML000*. 8 QLC(Y0./.0- =0.0 =0.8 =0.8 =0. 0GDL- 0.. ML00* QLC(Y0.0/.0- =0.0 =0. =0. =0.0 0GDL- 0. ML00* QLC(Y0.7/.- =0.0 =0.8 =0.8 =0.7 0GDL- 0.. ML00* QLC(Y0./.- =0.0 =0. =0. =0. 0GDL- 0. ML00*0.. 8 QLC(Y0./.0- =0.0 =0.8 =0.8 =0. 0GDL- 0.. ML00* QLC(Y0.0/.0- =0.0 =0. =0. =0.0 0GDL- 0. ML00*0.. 8 QLC(Y0.7/- =0.0 =0.8 =0.8 =0.7 0GDL- 0.. ML0*.0 0 QLC(Y0./- =0.0 =0. =0. =0. 0GDL- 0. ML0*0. 8 QLC(Y0.7/.0- =0.0 =0.8 =0.8 =0.7 0GDL- 0.. ML000*.0 0 QLC(Y0./.0- =0.0 =0. =0. =0. 0GDL- 0. ML000*0. 8 QLC(Y0.8/.0- =.0 =.00 =0.7 =0.8 0GDL ML00*. 8. QLC(Y0.0/.0- =0.7 =0.70 =0.7 =0.0 0GDL- 0.7 ML00* QLC(Y0./.- =.0 =.00 =0.7 =0. 0GDL ML00*.. QLC(Y0.8/.- =0.7 =0.70 =0.7 =0.8 0GDL- 0.7 ML00* QLC(Y0.8/.0- =.0 =.00 =0.7 =0.8 0GDL ML00*.. QLC(Y0./.0- =0.7 =0.70 =0.7 =0. 0GDL- 0.7 ML00*.0. 8 QLC(Y0./- =.0 =.00 =0.7 =0. 0GDL ML0*. QLC(Y0.8/- =0.7 =0.70 =0.7 =0.8 0GDL- 0.7 ML0*.0 0 QLC(Y0./.0- =.0 =.00 =0.7 =0. 0GDL ML000*. QLC(Y0.8/.0- =0.7 =0.70 =0.7 =0.8 0GDL- 0.7 ML000*.0 QLC(Y0.8/.0- =. =. =. =0.8 0GDL- 8.. ML00*. 8. QLC(Y0./.0- =0.0 =0.8 =0.8 =0. 0GDL8-0. ML00*.0 8. QLC(Y0./.- =. =. =. =0. 0GDL- 8.. ML00*.. 7 QLC(Y0.7/.- =0.0 =0.8 =0.8 =0.7 0GDL8-0. ML00*.0. QLC(Y0.7/.0- =. =. =. =0.7 0GDL- 8.. ML00*.. 8 QLC(Y0./.0- =0.0 =0.8 =0.8 =0. 0GDL8-0. ML00*.0. QLC(Y0./- =. =. =. =0. 0GDL- 8.. ML0*. QLC(Y0.7/- =0.0 =0.8 =0.8 =0.7 0GDL8-0. ML0*.0 QLC(Y0./.0- =. =. =. =0. 0GDL- 8.. ML000*. QLC(Y0.7/.0- =0.0 =0.8 =0.8 =0.7 0GDL8-0. ML000*.0 QLC(Y0.77/.0- =. =.0 =.7 =0.77 0GDL-.. ML00*. 8. QLC(Y0.8/.0- =.0 =.00 =0.7 =0.8 0GDL8-7.0 ML00* QLC(Y0.7/.- =. =.0 =.7 =0.7 0GDL-.. ML00*.. QLC(Y0./.- =.0 =.00 =0.7 =0. 0GDL8-7.0 ML00*.. 8 QLC(Y0.7/.0- =. =.0 =.7 =0.7 0GDL-.. ML00*.. QLC(Y0.8/.0- =.0 =.00 =0.7 =0.8 0GDL8-7.0 ML00*.. QLC(Y0.7/- =. =.0 =.7 =0.7 0GDL-.. ML0*. QLC(Y0./- =.0 =.00 =0.7 =0. 0GDL8-7.0 ML0*. QLC(Y0.7/.0- =. =.0 =.7 =0.7 0GDL-.. ML000*. QLC(Y0./.0- =.0 =.00 =0.7 =0. 0GDL8-7.0 ML000*.

7 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT (Ma specs pressure (Ma flow (L/s ower (kw of pump specs Total volume (m Effective water volume (m of QLC(Y0.8/.0- =. =. =. =0.8 0GDL8-8. ML00* QLC(Y0./.- =. =. =. =0. 0GDL8-8. ML00*.. 8 QLC(Y0.7/.0- =. =. =. =0.7 0GDL8-8. ML00*.. QLC(Y0./- =. =. =. =0. 0GDL8-8. ML0*. (H 0 QLC(Y0./.0- =. =. =. =0. 0GDL8-8. ML000*. A-A DN QLC(Y0.7/.- =. =.0 =.7 =0.7 0GDL8-.. ML00*.. DN QLC(Y0.7/.0- =. =.0 =.7 =0.7 0GDL8-.. ML00*.. QLC(Y0.7/- =. =.0 =.7 =0.7 0GDL8-.. ML0*. H H DN QLC(Y0.7/.0- QLC(Y0.8/.0- =. =.0 =.7 =0.7 =.0 =. =. =0.8 0GDL8-0GDL ML000*. ML00*. 8. H L L L L L L n- d W W W 7 QLC(Y0.8/.- =.0 =. =. =0.8 0GDL8-0.. ML00*.. 8 QLC(Y0.8/.0- =.0 =. =. =0.8 0GDL8-0.. ML00*.. QLC(Y0.8/- =.0 =. =. =0.8 0GDL8-0.. ML0*. A A 0 QLC(Y0.8/.0- =.0 =. =. =0.8 0GDL8-0.. ML000*. W L/s Remark:. upper limit of pressure stabilization, lower limit of pressure stabilization, pump to start, the pressure for a fire fighting lower limit of fire fighting water supply pressure;.the effective water volume in the table of model selection is calculated from the total volume upon the designed therein, that means the effective volume will varies along with the change of the ;.The effective water volume is set for satisfying the ten-min water supply at the initial of fire fighting, so it needs to be set upon the fire fighting flow (L/s and more than or equal to the water used time;.any product according to the actual need of users can be made to order, if no suitable one can be found within the standard ones. DN d n- (W

8 mm d QLC(Y0./.0- QLC(Y0./.- QLC(Y0.0/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.7/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0./.0- QLC(Y0./.- QLC(Y0./.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0./.0- QLC(Y0./.- QLC(Y0./.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0./.0- QLC(Y0./.- QLC(Y0./.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.7/.0- QLC(Y0.7/.- QLC(Y0.7/.0- QLC(Y0.7/- QLC(Y0.7/.0- QLC(Y0.8/.0- QLC(Y0.7/.- QLC(Y0.8/.0- L L L L L L W W W W W W H H H H DN DN DN DN n n d W (" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" mm d QLC(Y0.7/- QLC(Y0.7/.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.7/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0./.0- QLC(Y0./.- QLC(Y0./.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0./.0- QLC(Y0./.- QLC(Y0./.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.0/.0- QLC(Y0.8/.- QLC(Y0.0/.0- QLC(Y0.8/- QLC(Y0.8/.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.8/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.7/.0- QLC(Y0.7/.- QLC(Y0.7/.0- QLC(Y0.7/- QLC(Y0.7/.0- QLC(Y0.8/.0- L L L L L L W W W W W W H H H H DN DN DN DN n n d W (" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT

9 mm d QLC(Y0./.- QLC(Y0.8/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.0/.0- QLC(Y0./.- QLC(Y0.0/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.0/.0- QLC(Y0.8/.- QLC(Y0./.0- QLC(Y0.8/- QLC(Y0.8/.0- QLC(Y0./.0- QLC(Y0.7/.- QLC(Y0./.0- QLC(Y0.7/- QLC(Y0.7/.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.8/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.7/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.77/.0- QLC(Y0.7/.- QLC(Y0.7/.0- QLC(Y0.7/- L L L L L L W W W W W W H H H H DN DN DN DN n n d W (" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" mm d QLC(Y0.7/.0- QLC(Y0.8/.0- QLC(Y0.8/.- QLC(Y0.8/.0- QLC(Y0.8/- QLC(Y0.8/.0- QLC(Y0.0/.0- QLC(Y0./.- QLC(Y0.0/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.0/.0- QLC(Y0.8/.- QLC(Y0./.0- QLC(Y0.8/- QLC(Y0.8/.0- QLC(Y0./.0- QLC(Y0.7/.- QLC(Y0./.0- QLC(Y0.7/- QLC(Y0.7/.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.8/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.8/.0- QLC(Y0./.- QLC(Y0.7/.0- QLC(Y0./- QLC(Y0./.0- QLC(Y0.77/.0- QLC(Y0.7/.- L L L L L L W W W W W W H H H H DN DN DN DN n n d W (" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" 0(" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" (" QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT

10 QLC(Y SERIES EMERGENCY FIRE FIGHTING WATER SULY EQUIMENT mm d H DN DN DN DN n d n L L L L L L W W W W W W H H H W 0 QLC(Y0.7/ (" (" 0 QLC(Y0.7/ (" (" 0 QLC(Y0.7/ (" (" 0 0 QLC(Y0.8/ (" (" 0 7 QLC(Y0.8/ (" (" 0 8 QLC(Y0.8/ (" (" 0 QLC(Y0.8/ (" (" 0 0 QLC(Y0.8/ (" (" recautions in installation:.take convenient repair and disassembly into consideration on the installation space and also pay attention to water drainage and ventilation..use self-pouring water abstraction with the equipment and set an individual water-suction pipe with each pump..recommended to keep the water supply from the municipal works, provided that the pressure of the pipe-net of the municipal works is stable and can often meet with the upper limit of pressure stabilization..foot bolts may not be used in the equipment installation, just place it on a poured basis of sufficient bearing capacity. When to use foot bolts, preset the foot holes upon the size in the table and, after get it positioned, lay down the bolts and then pour concrete..both sewage port and pressure discharge port are screw connected and other joints are flange connected.. See the failure troubleshooting of their own for the failures with the pump, electric control cabinet.. Connect the control circuit correctly upon the electric control wiring diagram.. Before work, check and get all the valves at their right open-close positions.. After the equipment is put into normal work, it is -7 / suggested to manually drain out the water inside of the pump, - if not working for a long time, in a fixed time (-7days/once and let each pump run for -min.. Set an upward-drawing device (such as a vacuum pump, a vacuum tank etc. in case of upward-sucking water leading.. Inspect the pneumatic tank and safety valve once a year. Failure Cause Troubleshooting a a Water leaks from pipe network Fix the sealing face b b Check valve damaged Replace check valve c c frequently started Rubbish exists on the sealing face of check valve Get rid of rubbish d d Air leaks from the air room of pneumatic tank Fix the sealing face e e The capsule of pneumatic tank damaged Replace capsule a a Water leaks from pipe network Fix the sealing face b b Check valve damaged Replace check valve unable to stop c c Rubbish exists on the sealing face of check valve Get rid of rubbish d d Too high air-filling pressure with pneumatic tank Exhaust and lower the pressure Safetyvalveunabletobeclosed Safety valve does not go back to place after being opened Slightly knock on the body Equipment vibrated Fixing bolt loosened Tighten it Remark: see the failure troubleshooting of their own for the failures with water pump and electric control cabinet.

SSV Special Compensating Bypass Check Valve

SSV Special Compensating Bypass Check Valve V 18-0 pecial Compensating Bypass Check Valve ew - 0 ANI 0-0 Δp V R V pecial Compensating Bypass Check Valve V 18-0 (type with integrated non-return valve in the bypass) Range of Applications Compared

More information

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive ICON SERIES IDRIVE Intelligent Constant Pressure Water Supply Controller User Manual idrive1150-240 CONTENTS PREFACE 3 1. PRODUCT DESCRIPTION 4 1.1 Functions Description 4 1.2 Model List 4 1.3 Nameplate

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

DN100 (4") - DN500 (20") Hot Tappings

DN100 (4) - DN500 (20) Hot Tappings DN00 (4") - DN500 (20") Hot Tappings TONISCO B40 Hot Tapping Machine is versatile and easy to operate. It has a full range capability of setting valves DN00 DN500 by completing it with proper adapters.

More information

Oil Free Scroll. Air Compressors

Oil Free Scroll. Air Compressors Oil Free Scroll Air Compressors History of HITACHI Air Technology 1910 1930 1950 1970 1980 1911: 75kW Reciprocating First Compressor in Japan 1977: Smallest 5.5kW Oil Injected Rotary Screw 1976: Oil Injected

More information

Installation and Operation Manual SPC1

Installation and Operation Manual SPC1 Installation and Operation Manual SPC1 BIA-SPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMP FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMP FLOAT CONNECTED TO PUMP 6-7 QUICK GUIDE

More information

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0) User Manual AquaControl + Rainwater System Controller Item no.: 351027 Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0)7641-5890 Kunststofferzeugnisse D-79 331 Teningen Fax: +49(0)7641-58950 Page 1 Figure

More information

User & Maintenance Manual (original)

User & Maintenance Manual (original) User & Maintenance Manual (original) Type: IMPORTANT Carefully read this User Manual and follow the instructions and warnings before operating the machine. Any modification or change may cause the loss

More information

DN40 (1 1/2") - DN200 (8") Hot Tappings

DN40 (1 1/2) - DN200 (8) Hot Tappings DN40 ( /2") - DN200 (8") Hot Tappings TONISCO B30 Hot Tapping Machine is versatile and easy to operate. It has a full range capability of setting valves DN40 DN200 by completing it with proper adapters.

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

Installation and Operation Manual DPC1

Installation and Operation Manual DPC1 Installation and Operation Manual DPC1 BIA-DPC1 rev 5 Page 1 TABLE OF CONTENTS Page QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PANEL 4-5 QUICK GUIDE DRAINAGE PUMPS FLOATS CONNECTED TO PUMPS 6-7 QUICK

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4

OPERATION MANUAL E/P REGULATOR MODEL NAME. Series. For DeviceNet TM CONTENTS. Contents. Safety Instructions. Precautions for Handling P3-4 OPERATION MANUAL E/P REGULATOR MODEL NAME ITV*0*0 *0*0-DE**** series Series For DeviceNet TM CONTENTS TM Contents Safety Instructions P1 P2 Precautions for Handling P3-4 Wiring and LED display P5-6 Mounting

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

REMOTE THROTTLE. FOR CUMMINS CELECT and CELECT+ ENGINES SERIES M11, N14, L10 MODEL : RTU 1 OPERATING INSTRUCTIONS IDLE SETTING RTU

REMOTE THROTTLE. FOR CUMMINS CELECT and CELECT+ ENGINES SERIES M11, N14, L10 MODEL : RTU 1 OPERATING INSTRUCTIONS IDLE SETTING RTU REMOTE THROTTLE FOR CUMMINS CELECT and CELECT+ ENGINES SERIES M11, N14, L10 MODEL : RTU 1 OPERATING INSTRUCTIONS PRESET FRC IDLE INCREASE s 1200 SETTING s DECREASE RTU FIRE RESEARCH CORP. 26 Southern Blvd.,

More information

Installation & Operation and Maintenance

Installation & Operation and Maintenance Gas Safety Products Dual Current Monitor Installation & Operation and Maintenance Read these instructions carefully before operating or servicing Rev: 01 Date: 12-02-18 1 CONTENTS Chapter Content Page

More information

SAFETY re-defined. Backwater Protection. The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection. Quality Safety Success

SAFETY re-defined. Backwater Protection. The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection. Quality Safety Success SAFETY re-defined Backwater Protection The new Staufix FKA/SWA and Pumpfix F series Top-level backwater protection Quality Safety Success Backwater protection: KE System innovations Body with only mm gradient

More information

Spare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7

Spare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Spare part catalogue 0020037555.03 GB 03/2007 Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Content General view of sheet Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

shop online:

shop online: Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid

More information

GRUNDFOS INSTRUCTIONS. Hydro 2000 F. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Hydro 2000 F. Installation and operating instructions GRUNDFOS INSTRUCTIONS Hydro 2000 F Installation and operating instructions Declaration of Conformity We GRUNDFOS declare under our sole responsibility that the products Hydro 2000 F, to which this declaration

More information

Manual Control Unit GFCD 16

Manual Control Unit GFCD 16 Manual Control Unit 1400002_EN/04.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Filter taps 5 7. Settings 6 8.

More information

Compressor Controller MAM 890

Compressor Controller MAM 890 Compressor Controller MAM 890 OPERATION MANUAL Revision 1.0 04.08.2017 Notice Please read all the operation manual before operating the set and keep this manual for further reference. Installation of MAM

More information

"PVL" SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev)

PVL SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev) "PVL" SERIES Fixed Displacement - Single PVL Up to 5 (70 ), cm /rev (7 CU.IN./rev) Pub. EC-0 The PVL series single pumps are designed for use with small size machine tools requiring comparatively low pressure

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

Variable Area Flowmeters Installation Instructions G Series and M Series

Variable Area Flowmeters Installation Instructions G Series and M Series Variable Area Flowmeters Installation Instructions G Series and M Series Safety Definitions Potential danger to life or of serious injuries. Potential for personal injury from electrical shock. Safety

More information

AIR Compressor. Efficient Cooling System. PCG Series 01/02

AIR Compressor. Efficient Cooling System. PCG Series 01/02 AIR Compressor V-belt Connection Level energy efficiency motor Efficient motor specialized for compressors with long service life Rational configuration of compressors within the same range satisfies the

More information

Mini Design Inverter. For applications which need tiny installation space. HNC Electric Limited

Mini Design Inverter. For applications which need tiny installation space. HNC Electric Limited H V 90 Mini Design Inverter For applications which need tiny installation space HNC Electric Limited 07.8 About HNC Electric HNC Electric is an automation & drive focused global company, providing global

More information

Océ CS9060. User s Guide. Eco Solvent

Océ CS9060. User s Guide. Eco Solvent Océ CS9060 User s Guide Eco Solvent Océ CS9060 - INSTALLATION GUIDE Thank you for purchasing a Océ CS9060 Eco Solvent Printer! Please read this manual before using the printer, otherwise things might go

More information

DIP. Spare parts list. Centrifugal pumps 25, 25-US, 35, 35-US, 65, 65-US Atlas Copco Construction Tools AB No c

DIP. Spare parts list. Centrifugal pumps 25, 25-US, 35, 35-US, 65, 65-US Atlas Copco Construction Tools AB No c DIP 5, 5US, 35, 35US, 65, 65US Spare parts list Centrifugal pumps 0 Atlas Copco Construction Tools AB No. 9800 5 0c 003 DIP 5, 5US, 35, 35US, 65, 65US Contents Contents General information................................................................

More information

Can eliminate static charge over an extensive range

Can eliminate static charge over an extensive range No.BK-P3 Static Electricity Removing Unit Ionizer Wide Area Fan Type Overhead Fan Type Can eliminate static charge over an extensive range Wide area fan type RoHS compliant product Overhead fan type Static

More information

Ultra Filtration System

Ultra Filtration System Ultra Filtration System PTUF series have been engineering for permeate capacity ranging from 2.5T/H to 10T/H. Environmental World Products (China) Inc No.3, Lane 1015, South Boxue Road, Malu Town, Jiading

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

TEPI11 P/I signal converter

TEPI11 P/I signal converter Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation

More information

Gas Pressure Regulator HON

Gas Pressure Regulator HON Gas Pressure Regulator HON 0 0.0 OPERATING AND MAINTENANCE INSTRUCTIONS/ SPARE PARTS EDITION 0/07 Serving the Gas Industry Worldwide Contents page. General Remarks 3. Safety Instructions 3. Special Operating

More information

Operating Instructions Drill rigs DRU400 DRA400

Operating Instructions Drill rigs DRU400 DRA400 Operating Instructions Drill rigs DRU400 DRA400 Index 001 Original operating instructions 10988838 en / 12.05.2017 Congratulations! With a Hydrostress unit from TYROLIT you have chosen a tried and tested

More information

Mount Pleasant Waterworks. Cross-Connection Control Program Guidelines October 2010

Mount Pleasant Waterworks. Cross-Connection Control Program Guidelines October 2010 Mount Pleasant Waterworks Cross-Connection Control Program Guidelines October 2010 1 PREFACE The purpose of this policy is to protect the public water supply from the possibility of contamination. The

More information

Chiller Replacement and System Strategy. Colin Berry Account Manager

Chiller Replacement and System Strategy. Colin Berry Account Manager Chiller Replacement and System Strategy Colin Berry Account Manager Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit

More information

Rack & Enclosure Systems

Rack & Enclosure Systems Knürr CoolTherm 4 35 KW Energy-efficient Server Cabinet Technology With Outstanding Benefits, To Minimize Energy Costs In The Data Center And Help Reduce Carbon Dioxide Emmisions Rack & Enclosure Systems

More information

LS 5000 series Vibration Level Switch for liquids

LS 5000 series Vibration Level Switch for liquids Vibration Level Switch for liquids Set-up without adjustment Integrated fault monitoring Unaffected by product variations in density, conductivity, dielectric constant or viscosity Insensitive to foam,

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703

SC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703 SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION

More information

We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity.

We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity. We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity. ENGINEERED FOR SUPERIOR PERFORMANCE Compressed Air & Gas Systems

More information

MODEL : Nozzle. Hand shower. Top shower WS-501. Drawing of water connection. Cold/hot water switch. Water fall. Steam generator. Function shift switch

MODEL : Nozzle. Hand shower. Top shower WS-501. Drawing of water connection. Cold/hot water switch. Water fall. Steam generator. Function shift switch Drawing of water connection Top shower Function shift switch Cold/hot water switch Hand shower Install manual Steam bathroom MODEL : WS-50 Nozzle Cold water connection (blue pipe) Hot water connection

More information

Safety valves. Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50

Safety valves. Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50 Safety valves Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50 IMI PNEUMATEX / Accessories and Service / Safety valves Safety valves For the safeguarding of thermostatically

More information

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002 S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................

More information

INSTALLATION & OPERATION

INSTALLATION & OPERATION INSTALLATION & OPERATION MANUAL FOR MultiTrode Indicator Controller (MTIC) & MultiTrode Remote Indicator Controller (MTRIC) MTIC - Indicator Controller MTRIC - Remote Indicator Controller Version 598 MTIC

More information

SOLARIMMERSION IV Advanced Installation Manual v1.9

SOLARIMMERSION IV Advanced Installation Manual v1.9 SOLARIMMERSION IV Advanced Installation Manual v1.9 1 Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio Forward and reversible plate Hatz Electric start 0 mm Hatz Electric start 0 mm Bio Hatz Electric start mm Bio Valid from serial number 0000 0000 0000 Contents Contents General information.....................................................................................................................................

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved. R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.

More information

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio LH 00 Spare parts list Forward and reversible plate LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio Valid from serial

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AS8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ

LINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ Hitachi screw chiller unit widely used for air conditioning and industrial purposes Newly released, equipped with a new screw compressor realizing drastic energy saving and great functionality ( RCUP75AUZ

More information

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control

FEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control APPLICATIONS FEATURES Flood control Irrigation Land drainage Pollution control Industry Water refineries Water parks Design OPERATING DATA Capacity:...up to.000 m/h Head:...up to m Max. water temperature:...0

More information

Close-coupled centrifugal pumps

Close-coupled centrifugal pumps CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

ORB TM 4-20 ma Input Box Installation & Operation Manual

ORB TM 4-20 ma Input Box Installation & Operation Manual IOM ORB TM 4-20 ma Input Box Installation & Operation Manual ORB TM 4-20 ma Input Box Installation & Operation Manual CONTENTS I. HANDLING & STORAGE... 1 Inspection and Handling Disposal and Recycling

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac KG9-AR- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 8 8- Fax +49 8 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart

More information

Installation and Operation Guide

Installation and Operation Guide Installation and Operation Guide Table of Contents Safety Introduction 3 Package Contents 4 Installation 5 Setup and Configuration 6 Operation 7 Maintenance 8 Troubleshooting 9 Specifications Safety This

More information

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to

More information

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016 Operating Instructions Power Supply & Latching Relay For Switches Model: RL-6000 manual_rl-6000_1016 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

Thermal Mass Flowmeter Sensyflow FMT200-D

Thermal Mass Flowmeter Sensyflow FMT200-D Data Sheet Thermal Mass Flowmeter Sensyflow FMT200-D Direct measurement of mass flow or standard volume flow of compressed air, nitrogen and biogas independent of media pressure and temperature Wide measuring

More information

Edge banders CNC machining centres Vertical panel saws Pressure beam saws Panel Handling. Nesting Technology with High-End Format DYNESTIC 7521

Edge banders CNC machining centres Vertical panel saws Pressure beam saws Panel Handling. Nesting Technology with High-End Format DYNESTIC 7521 Edge banders CNC machining centres Vertical panel saws Pressure beam saws Panel Handling Nesting Technology with High-End Format DYNESTIC 7521 P R O D U C T I V I T Y A N D P R E C I S I O N D Y N E S

More information

DVFP Series Variable Frequency Drive - Product Manual. pg. 1

DVFP Series Variable Frequency Drive - Product Manual. pg. 1 pg. 1 Set Up Instructions for DVFP Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. Remove the system from the packaging. Make sure everything is included and

More information

MP54 SOUND for AC track power by

MP54 SOUND for AC track power by ACv0 MP54 SOUND for AC track power by CAUTION: THIS DEVICE CAN BE DAMAGED BY STATIC DISCHARGE. PLEASE EXERCISE CARE DURING INSTALLATION TO AVOID THIS POSSIBILITY. DISCHARGE YOURSELF TO AN ELECTRICAL GROUND

More information

Operating and installation instructions Differential pressure monitor

Operating and installation instructions Differential pressure monitor Operating and installation instructions Differential pressure monitor RM-DPC Micro SensorLine Table of contents 1 Safety instructions...3 2 Equipment specification...3 3 Assembly...4 4 Step-by-step installation...4

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP) High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes

More information

List of forms CLAP/WGP by subject /68/UE

List of forms CLAP/WGP by subject /68/UE List of forms CLAP/WGP by subject - 2014/68/UE Subject Assembly - Assembly including an item of pressure equipment placed on the market before 29 May 2002 in compliance with national pre-ped regulations

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

C-POWER AC AUTOMATIC CONTROL

C-POWER AC AUTOMATIC CONTROL Issue 1 Print 1 C-POWER AC AUTOMATIC CONTROL INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model: 93 ACMC100I A Charles Industries, Ltd. All rights reserved. Printed in the United States of America. Issue

More information

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_ Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573

More information

USER S MANUAL. TurboCharger Analyser Compact

USER S MANUAL. TurboCharger Analyser Compact USER S MANUAL TurboCharger Analyser Compact USE OF THE ORIGINAL EXHAUST (TURBINE HOUSINGS) FOR BEST TEST SIMULATION SIMPLE TO WORK WITH TO REDUCE THE TESTING TIME AMPLE AND WELL-LIT WORK AREA INDEX Introduction

More information

i. Prepare an SPCC plan in accordance with good engineering practices. (40 C.F.R )

i. Prepare an SPCC plan in accordance with good engineering practices. (40 C.F.R ) SPCC PLANS To prepare a Spill Prevention Control and Countermeasure (SPCC) plan in accordance with U.S. Code of Federal Regulations, Title 40, Part 112 (40CFR112), you must: i. Prepare an SPCC plan in

More information

Manual PCE-A 344W Microwave Consistency Sensor

Manual PCE-A 344W Microwave Consistency Sensor PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

Electronic Oil Meter OM 20

Electronic Oil Meter OM 20 INSTRUCTION MANUAL S1710, Rev A Electronic Oil Meter OM 20 Congratulations on purchase of this World Class Electronic Oil Meter! Electronic digital meter featuring an oval-gear measurement system. Designed

More information

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial

More information

Level switch NS 10/NS 25..-AM

Level switch NS 10/NS 25..-AM Level switch NS 10/NS 25..-AM Fluidcontrol Oil tanks in lubrication and oil supply systems are often under overpressure compared to the ambient atmosphere. All oil moistened parts of devices mounted externally

More information

Wafer Type Butterfly Valve

Wafer Type Butterfly Valve Rev.B Wafer Type Butterfly Valve Type Summary Butterfly valve actuator type Actuator Type Description Rated Output Force Supply* Control/ Feedback Signal Running Time Weight kg TBV-50-X.V Proportional

More information

ABB i-bus KNX HCC/S Heating/cooling circuit controller

ABB i-bus KNX HCC/S Heating/cooling circuit controller ABB i-bus KNX HCC/S 2.2.1.1 Heating/cooling circuit controller Description of product The device is a modular DIN rail component (MDRC) in pro M design. It is intended for installation in distribution

More information

VJ-1618 INSTALLATION MANUAL

VJ-1618 INSTALLATION MANUAL Please read this manual before using Thank you for purchasing a MUTOH product. This manual explains the steps for unpacking, mounting and basic installation before using the MUTOH Full-color inkjet printer

More information

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31

More information

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline

More information

High Pressure E/P Regulator. ITVH Series

High Pressure E/P Regulator. ITVH Series Doc. No. DIQ-69200-OM002-A P R O D U C T N A M E High Pressure E/P Regulator MODEL/ Series/ Product Number ITVH Series Install and operate the product only after reading the Operation Manual carefully

More information

DUKE UNIVERSITY CONSTRUCTION STANDARDS

DUKE UNIVERSITY CONSTRUCTION STANDARDS 1 00 01 10 Table of Contents DIVISION 00: PROCUREMENT AND CONTRACTING REQUIREMENTS 00 01 10 Table of Contents 06.17.2014 00 21 13 Instructions to Bidders 11.08.2013 00 22 13 Supplementary Instructions

More information

To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls.

To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls. MI 330 UNIVERSAL PROCESS CONTROL TRAINER OBJECTIVE To demonstrate wide range of experiments, applications and advanced control techniques using industry standard instrumentation and controls. FEATURES

More information

Furnace Camera System Operator s Manual. Version

Furnace Camera System Operator s Manual. Version Furnace Camera System Operator s Manual Version 12-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Specifications... 3 2.3 Confirmation of Camera Field of View...

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Collections Exam Need to Know Criteria

Collections Exam Need to Know Criteria Equipment Operation & Evaluation Class 1 Class 2 Class 3 Class 4 Operate drives X X X X Operate electronic testing equipment X X X X Operate hand and power tools X X X X Operate heavy equipment X X X X

More information

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS

H Manual Stretch Wrap Machine uline.com FILM ROLL CAPACITY TECHNICAL DATA ELECTRICAL SPECIFICATIONS TURNTABLE SPECIFICATIONS H-2304 Manual Stretch Wrap Machine 1-800-295-5510 uline.com SYSTEM SpecificationS IMPORTANT! Read this manual thoroughly and familiarize yourself with ALL controls and operating features. Keep this manual

More information

Vertex Pro Motor Driven Compressor Control

Vertex Pro Motor Driven Compressor Control Product Specification 03364 (Rev. A) Description Vertex Pro Motor Driven Compressor Control The Vertex-Pro is an anti-surge controller, designed to control and protect industrial-sized motor-driven axial

More information

Manual Control Unit GFC 16

Manual Control Unit GFC 16 Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down

More information

VARIABLE SPEED BOOSTER SYSTEMS AURORA INTELLIBOOST WITH INTELLIMANAGER. Distributed by Flow-Tech Industries

VARIABLE SPEED BOOSTER SYSTEMS AURORA INTELLIBOOST WITH INTELLIMANAGER. Distributed by Flow-Tech Industries AURORA INTELLIBOOST WITH INTELLIMANAGER VARIABLE SPEED BOOSTER SYSTEMS Certified to NSF/ANSI 61-G AURORA INTELLIBOOST Variable Speed Booster System Take A Leap Toward Technology The IntelliBoost Variable

More information

Pneumatic positioning module contiuous kpa output signal, with manual operation

Pneumatic positioning module contiuous kpa output signal, with manual operation 8 167 DEIGO I/O modules Pneumatic positioning module contiuous 0...138 kpa output signal, with manual operation Electro-pneumatic signal converter for connection to P-bus, output with a continuous control

More information