CFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000Pa Filter area: m²

Size: px
Start display at page:

Download "CFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000Pa Filter area: m²"

Transcription

1 CFL filters Complete and space-saving Plug & Play compressed-air cleaned filter unit with integrated fan to be used for air filtration from processes that form limited dust volumes (welding, cutting, grinding and similar). Can be placed in the production room and filters extraction from up to 7 simultaneous welding places. CFL: Air volume: Up to 8,200m³/h Vacuum: Up to 5,000 Filter area: m² Description filter unit Polluted air is led in through the lowest connection on unit side, wherein preseparator is integrated. Air is filtered through vertical-placed filter cartridge with internal filter core, which optimizes cleaning effect. Differential pressure controlled cleaning of filter cartridges through integrated compressed-air system incl. automatic after-cleaning for optimized regeneration of filter cartridges. Clean air is led out through connection in unit side. Dust is collected in dust container in unit bottom. Dust container mounted in Gram Quicklock-adjustable dust container suspension. Description fan Unit is above equipped with a fan type VAE or RAV, 3x400 VAC, 50 Hz, 2800 rpm. Both fans are equipped with closed fan wheel with backward-curved straight self-cleaning blades, static/dynamic balanced according to ISO (BV3 G 6.3). Fan delivers air in fan enclosure, where air noise is dampen by sound absorbing material, before it is led out through bolted-on connection. Simple mounting, connection and operation Unit delivered ready for use. Equipped with fork pockets and crane lifting points for easy transport and installation. Integrated motor starter and CEE-plug on front make connection quick and easy. Unit is also available for opera-tion with external frequency converter. In that case motor is delivered with built-in thermo sensor. Compressed-air supply is connected on unit by Cejn-coupling incl. ø10mm hose nipple. Easily accessible differential pressure reading in digital display of filter control placed countersunk on unit front. Quicklock-adjustable dust container on 4 wheels ensures user-friendly dust container service. Can be used for room ventilation/air cleaning and is available with W3-certificate For cleaning of slightly polluted room air containing e.g. welding smoke Filterline CFL52 and FAL 104 can be delivered with mounted air distribution modules that effects extraction of polluted air in top and returning clean filtered air at floor level (recirculation). Filter units with/without selected Airtower modules (CPFL) are available with W3-certificate. Automatic and compressed-air Filter- and motor control supplied by CEE-plug on front bar dry compressed-air is connected by Cejn-coupling incl. ø10mm hose nipple. Dust container Quicklock-dust container system with 35L or 57Ldust container is placed behind bottom front door. Easy filter replacement with limited dust generation Cartridge replacement is performed by bayonet suspension, which is loosened from clean air chamber and inserted into sack. Connections Air is sucked in by lower connection and leaves unit by upper connection. Inlet connection can be mounted right/left.

2 CFL filters Filters: Filter cartridge ø325mm. Length: 0/1320mm Filter control: Differential pressure control type BA with auftomatic after-cleaning. 230V AC (constant) Compressed-air: bar dry compressed-air by cejn-coupling incl. ø10mm hose nipple Differential pressure can be seen in digital display, placed countersunk on front 1 -jet valves connected to central compressed-air tank in clean air chamber Filter change: Cartridge replacement made easily and dust-reduced by filter bayonet suspension that is loosened from clean air chamber and inserted into sack. Access by front door. Filter material: Standard Material Used for G102 Polyester flake Dry not-static loaded or hygroscopic dust particles > 0.2µm Alternative G105 Cellulose/Polyester Welding/soldering G113 Polyester flake with PFPTcoating, Static-loaded or hygroscopic particles antistatic G115A Polyester flake with teflon membrane Finer dust sorts, e.g. cutting smoke from plasma, flame and laser cutting G116A Polyester flake with teflon membrane, antistatic Finer static-loaded dust sorts The filters meet demands for extraction degree for dust class M according to DIN EN Appendix AA (extraction degree > 99.9).

3 CFL filters Principle sketch for flow through Filterline type CFL with built-in fan: Fan enclosure lined with sound absorbing material reduces air noise. Internal filter core optimizes filter cartridge cleaning. Integrated preseparator optimizes filter life. Principle sketch for flow through Filterline type CFL without built-in fan: Tegnet af: Skala: MTO A4 Integrated preseparator optimizes filter life. Godkendt af: Dato f. godkendelse: Matr.: V.Å. GRAM A/ Internal filter core optimizes filter cartridge cleaning. FL flow-tegning

4 CFL filters Construction/surface Filterline type CFL is constructed acording to : Machine directive 2006/42/EU EMC-directive 2004/108/EU Directive 97/23/EU about pressure equipment Low voltage directive 2006/95/EU Harmonized standards: EN 349, EN 4414, EN 12100, EN , EN ISO Further standards: ISO 3746 Filter cabinet is made in 2mm black steel plate Surface powder enamelled RAL 5007/7011 structure Further is available: Version in hot-galvanized, enamelled steel plates for outdoor mounting Backdraft damper type KTR for piping placement ½ -water separator with manometer and pressure reducing valve Remote start/stop by magnetic operated motor protection 230VAC-coil voltage Channel silencer for noise damping in outlet air Leak detector type DTC/TC 30 Precoat unit type PCA ( ) Precoat 11.5kg in sack ( ) Unit with mounted Airtower air distribution modules (only CFL 52/VE 5500 and CFL 104/VE 7500) - see data sheet for Airtower modules type CPFL Unit designed for filtration of welding smoke class W3 - see data sheet for W3-version Photo: Filterline type CFL 26/VAE in RAL 7035/7011 with channel silencer Photo: Airtower type CPFL 52/VAE 5500

5 CFL filter Filterline type CFL is available in the sizes as stated in the forms below. Please, contact us for assistance in selecting the optimal unit taking into consideration air volume, dust type and volume, operation times etc. Filter type CFL without built-in fan: Type Type CFL 26/VAE ) CFL 26/VAE 6) CFL 26/RAV 35/3 6) CFL 52/VAE 6) CFL 52/VAE ) CFL 52/RAV 45 7) CFL 52H/VAE 6) CFL 52H/VAE ) CFL 52H/RAV 45 7) CFL 104/VAE ) CFL 104/VAE ) CFL 104/RAV 45 7) Delta P start/end 3) [] Delta P start/end 3) [] 1) Filter cartridge ø325 x 0mm/ø13.5mm, 13m², G102 2) Filter cartridge ø325 x 1320mm/ø13.5mm, 26m², G102 3) Pressure drop stated over filter cartridge 4) Supply plug 16A 5) Supply plug 32A 6) Delivered with hand-operated motor protection 7) Delivered with star-delta-starter Number jet valves Number jet valves G102 filter area [m²] G102 filter area [m²] G105 filter area [m²] G105 filter area [m²] Numbr filter cartridges Compressedair [L/min.] Numbr filter cartridges Compressedair [L/min.] Dust container [L] CFL / 2 1) CFL 52H 200/ 2 2) CFL / 4 1) CFL / 4 2) Filter type CFL with built-in fan: Dust container [L] Weight [kg] 200/ 2 1) / 2 1) / 2 1) / 4 1) / 4 1) / 4 1) / 2 2) / 2 2) / 2 2) / 4 2) / 4 2) / 4 2) CFL 104/RAV 500 5) 200/ 4 2) Weight [kg] Consumption data for Filter type CFL with built-in fan: Type VAE 2200-CFL-C2 VAE -CFL-C2 VAE -CFL-C2 VAE 5500-CFL-C2 VAE 7500-CFL-C2 RAV 35/3-CFL-C2 RAV 45-CFL-C2 Volt [V] [rpm.] [kw] Max. amp. Start current 3x x x x x x ) x RAV 50-CFL-C2 3x ) ) Increased efficiency Motor data > 0.75kW, 3x400V, according to IE2-motors.

6 CFL filter Filter type CFL with fan prepared for frequency regulator control: Type CFL 26/VAE 2200 Delta P start/end 3) [] 1) Filter cartridge ø325 x 0mm/ø13.5mm, 13m², G102 2) Filter cartridge ø325 x 1320mm/ø13.5mm, 26m², G102 3) Pressure drop stated over filter cartridge Number jet valves G102 filter area [m²] G105 filter area [m²] Numbr filter cartridges Compressedair [L/min.] Dust container [L] Weight [kg] 200/ 2 1) CFL 26/VAE 200/ 2 1) CFL 26/RAV 35/2 200/ 2 1) CFL 26/RAV 35/3 200/ 2 1) CFL 52/VAE 200/ 4 1) CFL 52/VAE / 4 1) CFL 52/RAV / 4 1) CFL 52H/VAE 200/ 2 2) CFL 52H/VAE / 2 2) CFL 52H/RAV / 2 2) CFL 104/VAE 5500 CFL 104/VAE 7500 CFL 104/RAV / 4 2) / 4 2) / 4 2) CFL 104/RAV / 4 2) Consumption data for Filterline type CFL with fan prepared for operation with frequency converter/ external motor starter: Type 4) Volt [V] [rpm.] [kw] Max. amp. Start current VAE 2200-CFL-C2 3x ,20 4,70 34,30 VAE -CFL-C2 VAE -CFL-C2 VAE 5500-CFL-C2 3x ,00 6,20 51,50 3x ,00 7,70 65,50 3x ,50 10,10 88,90 VAE 7500-CFL-C2 3x ,50 13,20 112,20 RAVH 35/2-CFL-C2 RAV 35/3-CFL-C2 RAV 45-CFL-C2 3x ,00 7,70 65,50 3x ,50 5) 10,30 93,80 3x ,50 13,20 112,20 RAV 50-CFL-C2 3x ,00 5) 19,50 156,00 4) Delivered incl. thermo sensor 5) Increased efficiency Motor data > 0.75kW, 3x400V, according to IE2-motors. Other technical data: Fan* Achieved efficiency Measurement category Efficiency category VSD Production year Manufacturer page Modul number/ type Rated motor power input, flow rate and pressure kw m³/h (Ps) Rpm. Specific ratio Disposal page Environment page Mounting measurement page VAE 2200-CFL-C2 48,4 D Total No CE-mark A , ,02 A15 A15 A15 VAE -CFL-C2 48,3 D Total No CE-mark A , ,02 A15 A15 A15 VAE -CFL-C2 54,0 D Total No CE-mark A , ,02 A15 A15 A15 VAE 5500-CFL-C2 60,4 D Total No CE-mark A , ,02 A15 A15 A15 VAE 7500-CFL-C2 59,0 D Total No CE-mark A , ,02 A15 A15 A15 RAV 35/2-CFL-C2 55,4 D Total No CE-mark A , ,04 A15 A15 A15 RAV 35/3-CFL-C2 60,0 D Total No CE-mark A , ,04 A15 A15 A15 RAV 45-CFL-C2 58,30 D Total No CE-mark A , ,03 A15 A15 A15 RAV 50-CFL-C2 61,2 D Total No CE-mark A , ,03 A15 A15 A15 * None of fans are subject to ERP 2013/2015 according to EU327/2011

7 CFL filter line Fan type VAE 2200-C2/VBS (CFL-cabinet) m³/h Fan type VAE -C2/VBS (CFL-cabinet) m³/h Fan type VAE -C2/VBAS (CFL-cabinet) m³/h

8 CFL filter line Fan type VAE 5500-C2/VBS (CFL-cabinet) m³/h Fan type VAE 7500-C2/VBS (CFL-cabinet) m³/h Fan type RAV 35/2-C2/VBS (CFL-cabinet) m³/h

9 CFL filter line Fan type RAV 35/3-C2/VBS (CFL-cabinet) m³/h Fan type R AV 45-C2/VBS (CFL-cabinet) m³/h Fan type R AV 50-C2/VBS (CFL-cabinet) m³/h

10 CFL filter line Filterline type CFL with built-in fan: Type A B C D E F G H I J K L M CFL 26/VAE ø ø CFL 26/VAE ø ø CFL 52/VAE ø ø CFL 52/VAE ø ø CFL 52/RAV ø ø CFL 104/VAE ø ø CFL 104/VAE ø ø CFL 104/RAV ø ø CFL 104/RAV ø ø

11 CFL filter line Filterline type CFL with built-in fan: Type A B C D E F G H I J K L M CFL 26/RAV 35/ ø ø CFL 26/RAV 35/ ø ø CFL 52H/VAE ø ø CFL 52H/VAE ø ø CFL 52H/RAV ø ø

12 CFL filter line Filterline type CFL H without built-in fan: Type A B C D E F G H I J K CFL ø ø CFL 52H ø ø CFL ø ø CFL ø ø

FMC cartridge filter. Compact cartridge filter for solving dust problems within a wide range of industries

FMC cartridge filter. Compact cartridge filter for solving dust problems within a wide range of industries Compact cartridge filter for solving dust problems within a wide range of industries The FMC cartridge filter series offers many operational benefits thanks to its compact design and patented UniClean

More information

Filter Fan Unit LIGHT

Filter Fan Unit LIGHT Filter Fan Unit LIGHT Type LIGHT EC Technical Concept Technical Concept Filter Fan Unit LIGHT Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air to individual

More information

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC Technical Concept Filter Fan Unit LIGHT Type LIGHT AC Type LIGHT EC Filter Fan Unit LIGHT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean air

More information

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw Chiller CG 010 to 130 Remote Air Cooled Condensers Engineering Data Manual 9.4 to 131 kw Specifications Unit identification CG. O. O55. FSC. R407C LN Configuration Refrigerant rpm fans Size Air flow Remote

More information

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks

Technical Concept. Tunnel Air Shower. All Types Air Shower / Air Locks Technical Concept Tunnel Air Shower All Types Air Shower / Air Locks Tunnel Air Shower Technical Concept Product Description Personnel air showers minimize the transfer of dust particles on cleanroom clothing

More information

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC Technical Concept Filter Fan Unit RETURN AIR Type RA-AC Type RA-EC Filter Fan Unit RETURN AIR Technical Concept Product Description Technical Data M+W Products Filter Fan Units RETURN AIR (FFU-RA) are

More information

v E h i c l E h E at E r s ThE spare parts list is only valid for ThE following ENgiNE- independent water heaters

v E h i c l E h E at E r s ThE spare parts list is only valid for ThE following ENgiNE- independent water heaters Vehicle Heaters Technical Documentation EN Spare parts list Hydronic II The spare parts list is only valid for the following engineindependent water heaters Heaters for petrol B 4 S 12 V 20 1909 05 00

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement.

NEOSTAR AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE HFC. 18 > 1240 kw. NEOSTAR POWER The choice of performance and low space requirement. AXIAL FAN CONDENSER COMMERCIAL AND INDUSTRIAL RANGE Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres Food processing - Canteen kitchens HFC 18 >

More information

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers

Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers Chilled Water Computer Room Air Handler (CRAH) Critical Infrastructure for the World s Leading Data Centers DATA CENTER COOLING EXPERTISE Data Center managers have unique needs. Nortek Air Solutions listens

More information

Manual Control Unit GFCD 16

Manual Control Unit GFCD 16 Manual Control Unit 1400002_EN/04.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Filter taps 5 7. Settings 6 8.

More information

IDS 500 mobile Intelligent mobile chart recorder

IDS 500 mobile Intelligent mobile chart recorder IDS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

VLT The general purpose drive. Phone: Fax: Web: -

VLT The general purpose drive. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE VLT 2800 The general purpose drive The pace-setter among general purpose drives The VLT 2800 series are among the smallest multi-purpose drives in the market, designed for

More information

Chart recorder. DS 500 mobile Intelligent mobile chart recorder

Chart recorder. DS 500 mobile Intelligent mobile chart recorder DS 500 mobile Intelligent mobile chart recorder The intelligent mobile chart recorder - energy analysis according to DIN EN ISO 50001 Energy analysis - ow measurement - leakage calculation at compressed

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches.

Thermostat KP. Data sheet. The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. Data sheet Thermostat KP The KP Thermostats are single-pole, doublethrow (SPDT) temperature-operated electric switches. They can be connected directly to a single-phase AC motor of up to approx. 2 kw or

More information

PI 500 Hand-held instrument for industry

PI 500 Hand-held instrument for industry PI 500 Hand-held instrument for industry The new PI 500 is an all-purpose hand-held measuring instrument for many applications in industry like e. g.: Flow measurement Pressure/vacuum measurement Temperature

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

FEATURES AND BENEFITS. Installation and operation. Controller

FEATURES AND BENEFITS. Installation and operation. Controller DFC 350 & 450 DISPLACEMENT FREE COOLING Function The Dantherm Displacement Free Cooling (DFC) unit is a slim, passive cooling solution designed to remove excess heat from rooms with sensitive equipment.

More information

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions Controls Guide for XeteX Units Beyond meeting the typical specification and performance requirements, controlling the equipment is usually the most important success factor for HVAC projects. XeteX provides

More information

Furnace Camera System Operator s Manual. Version

Furnace Camera System Operator s Manual. Version Furnace Camera System Operator s Manual Version 12-2010 Contents 1. Introduction... 2 2. Description... 2 2.1 Model Nomenclature... 2 2.2 Specifications... 3 2.3 Confirmation of Camera Field of View...

More information

kyalfa V- VDD/VDD6 General Contents

kyalfa V- VDD/VDD6 General Contents General Contents. kyalfa V- VDD/VDD6 ky General Contents General Features A dry cooler is a forced convection air-cooled fluid cooler, designed for outdoor installation. Air is forced over the finned coil

More information

GTH. Rectangular double deflection grille QUICK FACTS

GTH. Rectangular double deflection grille QUICK FACTS Rectangular double deflection grille QUICK FACTS For supply air Adjustable air deflectors Cleanable Installed using mounting frames FHB / FHA or commissioning box TRG Standard colour White RAL 900 -- alternative

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c. Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing

More information

Model VDL 115 Vacuum drying chambers for flammable solvents

Model VDL 115 Vacuum drying chambers for flammable solvents Model VDL 115 Vacuum drying chambers for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with TÜV/GS. The inner chamber

More information

Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO

Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO CMRS-X Belt-driven fans fitted with electric motors and a standardised set of pulleys, belts and protectors in accordance with standard ISO 13857. Fan: Sheet steel casing. Impeller with reaction blades

More information

Diagonal, xx-4. User manual Mounting instruction. Keep this folder with product at all times! PDF 6117 /

Diagonal, xx-4. User manual Mounting instruction. Keep this folder with product at all times! PDF 6117 / Diagonal, 30-409xx-4 User manual Mounting instruction Keep this folder with product at all times! PDF 6117 / 30.09.2014 Page 1 Ropox 2014 Table of Contents TABLE OF CONTENTS... 1 1. INTRODUCTION... 3 2.

More information

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U) (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications

More information

Flow VA 500/

Flow VA 500/ VA 500/ 520 Verbrauch 79 What are the advantages of the flow measuring technology of CS Instruments? 1) 500 is mounted by means of a standard 1/2 ball valve. During mounting and dismounting the safety

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Blue e+ chillers with the principle

Blue e+ chillers with the principle Blue e+ chillers with the principle Blue e+ chillers The world s most efficient range of chillers. The principle: Efficient Energy savings of up to 70% thanks to DC inverter technology Flexible Worldwide

More information

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD Air-Cooled Condensers/Air-Cooled Fluid Coolers 09LD/GD 09GD 09LD/GD Nominal cooling capacity 281-987 kw The 09LD air-cooled condensers are designed for refrigeration plants where a halogenated hydrocarbon,

More information

Manual Control Unit GFC 16

Manual Control Unit GFC 16 Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down

More information

START & GRIND. A complete assortment of floor grinders and dust extractors for an easy grinding experience. htc-floorsystems.com

START & GRIND. A complete assortment of floor grinders and dust extractors for an easy grinding experience. htc-floorsystems.com START & GRIND A complete assortment of floor grinders and dust extractors for an easy grinding experience. htc-floorsystems.com 1 HTC PRESENTS MACHINES FOR AN EASY GRINDING EXPERIENCE HTC is introducing

More information

Technical data sheets

Technical data sheets echnical data sheets Ready-to-connect spring return actuator with emergency function for VAV and CAV units in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m 2 orque

More information

Pulsatron Compact Range. High efficiency cartridge dedusting filters with compressed air self-cleaning system

Pulsatron Compact Range. High efficiency cartridge dedusting filters with compressed air self-cleaning system Pulsatron Compact Range High efficiency cartridge dedusting filters with compressed air self-cleaning system Hascon Engineering spa has been operating for 0 years in the field of air dedusting and filtering

More information

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS RAH 913 K AIR R-407C R-134a Series RAH... from 307 to 1879 kw - from 1 to 4 circuits The air cooled chillers of RAH series are extremely compact units so to reduce the installation spaces and weights.

More information

AIR Compressor. Efficient Cooling System. PCG Series 01/02

AIR Compressor. Efficient Cooling System. PCG Series 01/02 AIR Compressor V-belt Connection Level energy efficiency motor Efficient motor specialized for compressors with long service life Rational configuration of compressors within the same range satisfies the

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

Interface I-300 / I-300 Pro Technical data sheet

Interface I-300 / I-300 Pro Technical data sheet Interface I-300 / I-300 Pro Technical data sheet The Interface I-300 or I-300 Pro are the central control unit for all process parameters of a Rotavapor R-300 system: rotation speed, temperature (heating

More information

Lenntech BMP GRUNDFOS DATA BOOKLET. High-pressure piston pumps 50/60 Hz

Lenntech BMP GRUNDFOS DATA BOOKLET. High-pressure piston pumps 50/60 Hz Lenntech GRUNDFOS DATA BOOKLET BMP High-pressure piston pumps 50/60 Hz Contents Product data Introduction Page 3 Features and benefits Page 3 Applications Page 3 Pumped liquids Page 3 key Page 4 Motor

More information

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS Circular ceiling air diffuser for supply air QUICK FACTS Ceiling air diffuser for supply air in rooms with high ceiling Manual operated change of spread direction as standard Motor operated change of spread

More information

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers OEM CLIMATIX TM Room unit QAA822 with2- wire interface For use with Climatix controllers Remote control of air conditioning unit Mandík Measurement of the room temperature Buttons for starting, setting

More information

Room controller STRA-17

Room controller STRA-17 Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control

More information

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage The ideal extractor for industrial environments. New technology in combination with new materials and a focus on design gives Movex PR many new and important advantages: - Unique ease of maneuverability.

More information

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O Product Data Sheet CODEL Continuous Emission Monitoring GCEM4000 Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O In-situ, low maintenance devices for continuous process and emissions

More information

Blower and EC-filters

Blower and EC-filters 16.10.18 Blower and EC-filters The blower and EC-filter is an under- and over-pressure filter, designed for continuous operation.constructed as a self-supporting sheet metal construction. The round design

More information

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline

More information

Variable Speed Drives

Variable Speed Drives Technical Note 14 Variable Speed Drives On Single Phase Supplies Note: This article is intended as a guide only. It is the responsibility of the installer to define and accommodate all environmental &

More information

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors IDS 400 mobile Affordable, mobile chart recorder Energy analysis - ow measurement - leakage calculation at compressed air systems Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party

More information

Drawing on 40 years of

Drawing on 40 years of Systems Drawing on 40 years of blower and manufacturing experience, Republic Blower Systems are designed to outperform any blower on the market. Providing the ideal combination of powerful air movement,

More information

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_

Flow. Order number VA 550. Order no. VA 570. Further accessories A_...M_ Order number VA 550 housing High-pressure rig for VA 550 recoended for mounting from 10 to 100 bar Order no. 0695 0550 A_...M_ 0530 1155 Order no. VA 570 Order no. 0695 0570 0695 0571 0695 0572 0695 0573

More information

Interface I-300 / I-300 Pro Technical data sheet

Interface I-300 / I-300 Pro Technical data sheet Interface I-300 / I-300 Pro Technical data sheet The Interface I-300 or I-300 Pro are the central control unit for all process parameters of a Rotavapor R-300 system: rotation speed, temperature (heating

More information

North Power 5H04 PRIME POWER:454 KVA KW STANDBY POWER: 504 KVA KW

North Power 5H04 PRIME POWER:454 KVA KW STANDBY POWER: 504 KVA KW DATA SHEET North Power 5H04 STANDBY POWER: 504 KVA - 403 KW Standard Specifications Water cooled, Diesel engine Radiator with mechanical fan Protective grille for rotating and hot parts Electric starter

More information

Technical Manual Nova: Cabinet Security Management System (CSMS)

Technical Manual Nova: Cabinet Security Management System (CSMS) Technical Manual Nova: Cabinet Security Management System (CSMS) KP_nova_TM_160501_EN 1 Publication May, 2016, Keyprocessor BV Paasheuvelweg 20 1105BJ Amsterdam, The Netherlands www.keyprocessor.com/nova

More information

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB SKIVING MACHINE ASSK2 MAINTENANCE & INSTRUCTIONS MANUAL A. WARRANTY AND RESPONSIBILITY Warranty: It's the supplier's responsibility to guarantee the conformity of the product, assuring that it's manufactured

More information

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH

MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH MCFCW-20-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 60,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane Filter Caps for Humidity and Dewpoint Transmitters with probe 12 mm (0.47 ) The right choice of appropriate filter cap is essential for best long term performance in the application. For assistance please

More information

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH

MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH MCFCW-08-4LS-1 (4-Pipe) Low Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 24,000 BTUH 1 Chilled and Hot Water Fan Coil Low Static 4-Pipe Nominal Size:

More information

Thermal Diffusivity Instruments DLF-2 with EM-1600

Thermal Diffusivity Instruments DLF-2 with EM-1600 Thermal Diffusivity Instruments DLF-2 with EM-1600 Site Preparation Guide Revision A Issued February 2017 Table of Contents Table of Contents... 1 Ideal Setup... 2-3 System Components... 3 Instrument Measurements...

More information

Flow. Flow. N/en

Flow. Flow. N/en / poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated

More information

CC-80 and CC-160. R B Control details for CC-80-V Page 2. R B Control details for CC-160-V Page 3. R A Power Pack Parts Page 4

CC-80 and CC-160. R B Control details for CC-80-V Page 2. R B Control details for CC-160-V Page 3. R A Power Pack Parts Page 4 List of contents R-040.02.B Control details for CC-80-V Page 2 R-040.04.B Control details for CC-160-V Page 3 R-040.06.A Power Pack Parts Page 4 R-040.07.A Heater Details Page 5 R-040.09.A Container Details

More information

DISSOLVED OXYGEN MEASUREMENT

DISSOLVED OXYGEN MEASUREMENT DISSOLVED OXYGEN MEASUREMENT ACTEON 2030 TRANSMITTER Potentiometric measurement technology Robust, watertight, easy to install, Widescreen graphic display: instant measurements, trend line, relay state,

More information

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH

MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH MCFCW-06-4HS-1 (4-Pipe) High Static Chilled/Hot Water Ceiling Concealed Cased Fan Coil 208/230V 4-Pipe Heating & Cooling Fan Coil 18,000 BTUH 1 Chilled and Hot Water Fan Coil High Static 4-Pipe Nominal

More information

LW50A Series Facility Requirements

LW50A Series Facility Requirements LW50A Series Facility Requirements Effected Models: LW50A(C)(E), LW70A(C)(E) and LW150A(E) ML-2351A(F)(-CE), ML-2350A(F)(-CE), ML-2450A(-CE) Purpose The purpose of this document is to describe the facility

More information

AC5160 SiPass integrated controller kit

AC5160 SiPass integrated controller kit AC5160 SiPass integrated controller kit SiPass integrated Wall housing with pre-assembled basic SiPass integrated components Equipped with one ACC (AC5100), two dual reader interfaces (ADD5100) and one

More information

of the dew point curve/ the switching behavior of the dryer over a longer period of time.

of the dew point curve/ the switching behavior of the dryer over a longer period of time. DP 500/ DP 510 Portable dew point meters with data logger The new instruments DP 500/ DP 510 are the ideal portable service instruments for dew point measurement for all types of driers down to -80 Ctd

More information

Operating Instructions Wall saw DZ-S2

Operating Instructions Wall saw DZ-S2 Operating Instructions Index 001 10987273 EN /25.07.2007 Congratulations! With a Hydrostress unit from TYROLIT, you have chosen a tried and tested piece of equipment which has been designed and built to

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet SF24A-MOD Communicative spring-return actuator with emergency control function for adjusting dampers in technical building installations orque motor 20 Nm Nominal voltage AC/DC 24 V

More information

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool echnical data sheet LHA-MF..-P Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

Linear Luminaire with LED Series 6012/5

Linear Luminaire with LED Series 6012/5 > For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

DP 500/DP 510 Portable dew point meters with data logger

DP 500/DP 510 Portable dew point meters with data logger DP 500/DP 510 Portable dew point meters with data logger The new instruments DP 500/DP510 are the ideal portable service instruments for dew point measurement for all types of driers down to -80 Ctd dew

More information

EC centrifugal module - RadiPac

EC centrifugal module - RadiPac K3G-AP25-1 ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 81- Fax +49 7938 81-11 info1@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft echnical data sheet LH24A-MF2-P Parmeterisable linear actuator for adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 5 N Nominal voltage

More information

Pre-installation Manual

Pre-installation Manual Pre-installation Manual Rinse Gum Unit 85-125-165 Pre-installation Manual Rinse Gum Unit 85-125-165 T11018 Edition BA, March 2006 This book has part no 51477 0-2 Introduction Part 0: Introduction This

More information

Electromotoric actuator

Electromotoric actuator Acvatix Electromotoric actuator SUA21/3 For zone valves AC 230 V operating voltage, 2-position control signal Positioning force 170 N Direct mounting with M30 x 1.5 union nut (no tools required) 3-wire

More information

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)

High Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP) High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes

More information

IBIS. Duct diffuser with discs for supply air QUICK FACTS

IBIS. Duct diffuser with discs for supply air QUICK FACTS Duct diffuser with discs for supply air QUICK FACTS 0 flexible distribution pattern Suspended installation Easy installation Modular length: 00 mm Standard colour White RAL 900 -- alternative standard

More information

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors DS 400 mobile Affordable, mobile chart recorder Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party s Internal rechargeable Li-Ion batteries, approx. 8 h continous operation Easy

More information

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug Vibration Limit Switch Features Limit switch for liquids External function test with test magnet Onsite function check possible thanks to LED indication Large selection of process connections for hassle-free

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

Radiator Lockshield Valves ADN.. AEN..

Radiator Lockshield Valves ADN.. AEN.. 07 EN - Straight version ADN.. Angle version AEN.. ACVATIX TM Radiator Lockshield Valves ADN.. AEN.. for -pipe heating systems Valve bodies made of brass, mat nickel-plated DN 0, DN and DN 0 Integrated

More information

Room Temperature Controller

Room Temperature Controller 3 023 Room Temperature Controller for four-pipe fan coil units RCC30 Outputs for on / off valve actuators Outputs for three-speed fan Control depending on room or return air temperature Operating modes:

More information

Manual Simatek Control Unit GFC 32

Manual Simatek Control Unit GFC 32 Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections

More information

Linear Luminaire with LED Series 6412/5

Linear Luminaire with LED Series 6412/5 > For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless

More information

EC axial fan - HyBlade

EC axial fan - HyBlade WG-HU- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D- Mulfingen Phone +9 9 - Fax +9 9 - info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59 General

More information

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw IT COOLING EVAPORATIVE COOLING SYSTEM 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 8 TO 3 kw IT COOLING EVAPORATIVE COOLING SYSTEM ADIABATIC COOLING FOR HIGH EFFICIENCY - Variable

More information

Room Temperature Controllers

Room Temperature Controllers 3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic

More information

Dewatering pumps for raw water pumping GRUNDFOS DW RANGE. Dewatering pump kw

Dewatering pumps for raw water pumping GRUNDFOS DW RANGE. Dewatering pump kw Dewatering pumps for raw water pumping GRUNDFOS DW RANGE Dewatering pump 0.7-20 kw efficient state-of-art dewatering pumps Unique user benefits The Grundfos DW pumps form part of a complete range of wastewater

More information

PARTS LIST

PARTS LIST 2017.09.2 PARTS LIST TABLE OF CONTENTS Cabinet Push Clean & Basic & XC 1 Container ATTIX 30 4 Accessories 6 Filtersystem XC Filtersystem Push Clean & Basic 10 Motor Basic and Push Clean 12 Motor XC 14

More information

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems 6 EN - Straight valves VDN Angle valves VEN Reverse angle valves VUN Radiator Valves NF norm, for -pipe heating systems VDN VEN VUN Valve bodies made of brass, mat nickel-plated DN, DN and DN (VDN, VEN

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place.

Unpacking and Installing the Flora 2512 UV Printer. Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place. Unpacking and Installing the Flora 2512 UV Printer Steps 1: Unscrew the 10mm bolts holding the top. Then remove the top and put in a safe place. Step 2: Unscrew 10mm bolts holding the end panels. On the

More information

PARTS LIST

PARTS LIST 2016.12.09 PARTS LIST TABLE OF CONTENTS Cabinet and control panel 01 IC -21 IC - 2L IC 1 Filter system IC 3 Suction unit L 5 Base_M_L 7 Container 42L 9 Filter and bags 11 Hoses, tubes and nozzles 13 RECOMMENDED

More information