2/2 VALVES FOR WATER. Water 2 WAY VALVES. Actuation Body Function Specification Port
|
|
- Steven Griffin
- 6 years ago
- Views:
Transcription
1 The Parker 2 way valves (1 way for inlet and 1 way for outlet) for water and neutral liquids are optimized constructions for liquids handling. The exclusive diaphragm design gives a superior flow rate with one of the fastest response time. Typical applications are: and hot water supply in plumbing installations Breeding Irrigation Industrial washing machines Car washing systems Fire fighting These applications can be found in many markets dealing with water and hot water like plumbing, industries, water treatment, transportation, medical, process, etc Actuation Body Function Specification Port Size Pilot Operated (No minimum pressure required) Brass/ Pipe Mounting Normally Closed 3/8" to 2" 13 to () MOPD (bar) Manual override 1/2" Big / Anti water haer / Manual override 2 1/2" to 3" 65 to Normally Open 3/8" to 2" 13 to Page 41
2 V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 3/8" V/50Hz DIS Vdc DIS FKM V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 42
3 V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 1/2" V/50Hz DIS Vdc DIS FKM V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 43
4 V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 3/4" V/50Hz DIS Vdc DIS FKM V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 44
5 V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 1" V/50Hz DIS Vdc DIS FKM V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 45
6 1 1/4" /2" " V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 46
7 1/2" V/50Hz DIS Vdc DIS 47
8 2 1/2" " V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 48
9 NORMALLY OPEN V/50Hz DIS Vdc DIS 3/8" V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 1/2" V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 49
10 NORMALLY OPEN V/50Hz DIS Vdc DIS 3/4" V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 1" V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 50
11 NORMALLY OPEN V/50Hz DIS Vdc DIS 1 1/2" V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 2" V/50Hz DIS Vdc DIS V/50Hz DIS Vdc DIS 51
Pilot operated 2 port solenoid valve (general purpose valve) 100 VAC 50/60Hz 110 VAC 60Hz 200 VAC 50/60Hz 220 VAC 60Hz 12 VDC 24 VDC 48 VDC 100 VDC
D11/D1 Series (general purpose valve) D11/D1 Series NC (normally closed) type, NO (normally open) type Port size: Rc1/4 to Rc1 Diaphragm structure Refer to Ending 17 for more details. JIS symbol Common
More informationBlock diagram MB-VEF
0 0 Functional description Gas flow. If the valves and are closed, chamber a is under input pressure up to the double seat of valve.. A hole in the filter housing of MB-.../0 connects min. pressure switch
More informationPowermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control
Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control Description Features Application The Powermite 599 MT Series SAS Electronic Valve Actuator requires a 24 Vac
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationWall-mounted Heat Interface Unit HIU Instantaneous domestic hot water production Mechanical control
Wall-mounted Heat Interface Unit HIU Instantaneous domestic hot water production Mechanical control Code SATK DPCV ACCRDITD 04/ B ISO 900 FM 64 ISO 900 No. 000 Function The latest generation of mechanical
More informationICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive
ICON SERIES IDRIVE Intelligent Constant Pressure Water Supply Controller User Manual idrive1150-240 CONTENTS PREFACE 3 1. PRODUCT DESCRIPTION 4 1.1 Functions Description 4 1.2 Model List 4 1.3 Nameplate
More informationETV Control ETV Valve
R ISTALLATIO/OPERATI ISTRUCTIOS ELECTROIC TEMPERI VALVE () Actuator Display current temp and control settings LED indicates actuator operation 3 buttons to view and change settings L 1 2 3 4 5 6 7 8 9101112
More informationlectronic FasTest s ETS ool ystem Eliminate the mess Ultimate seal control Serial, Ethernet or DeviceNet
lectronic ool ystem FasTest s ETS is an electronic sealing device for leak test applications requiring ultimate seal control and clean operation. Our full featured drive systems provide Serial, Ethernet
More informationRadiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems
6 EN - Straight valves VDN Angle valves VEN Reverse angle valves VUN Radiator Valves NF norm, for -pipe heating systems VDN VEN VUN Valve bodies made of brass, mat nickel-plated DN, DN and DN (VDN, VEN
More informationDUKE UNIVERSITY DESIGN & CONSTRUCTION STANDARDS
1 33 19 00 District Thermal Energy and Water Utility Metering A. GENERAL 1. Duke FMD Utilities & Engineering Services operates district energy and water systems to provide power, heating, and cooling utilities
More informationQVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes
s 1 598 Flow sensor for liquids in DN10 25 pipes QVE3000.0xx QVE3100.0xx Vortex flow sensor made from robust red brass Output signal: DC 0 10 V or 4 20 ma Flow range: 1.8 150 l/min Used for temperature
More informationBartels Micropumps. DE Seite 14
EN DE Seite 14 Bartels Micropumps Micropumps transporting the tiniest amounts of gases or liquids can be considered the heart of microfluidics. In many sectors they have become indispensable. Dosing lubricants,
More informationRSK. Wafer Type Check Valve. Construction. Features. Advantages
Wafer Type Check Valve Construction The GEMÜ wafer type check valve is available in plastic or metal and the body, disc and seal can be chosen from various materials. The valve is clamped between two flanges
More information3/2 5/2 SERIES 362/562
Manual and Pilot Operated Spool Valves 6L Stainless Steel and Brass Bodies /4" to " NPT / / 6/6 Features Ideal for valve automation for the oil and gas market Reliable, robust design with high flow performance
More informationStandardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.
Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page
More informationLB74G - EXCELON Modular System General purpose filter/regulator
LBG - EXCELON Modular System > Port size: /... / (ISO G/PFT) > Push to lock adjusting knob with optional tamper resistant accessory > Excelon design allows in-line installation or modular installation
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES
The Transit Time Flow Meter of TTFM100 NEW GENERATION (NG) series measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe. This
More informationTECHNICAL FEATURES of A2 PANELS for ELECTRIC REMOTE CONTROLLED MONITORS
TECHNICAL FEATURES of A2 PANELS for ELECTRIC REMOTE CONTROLLED MONITORS General description The remote controlled monitors are available with foam/water flow rates from 50 up to 30.000 lt/min. and consequently
More informationElectronic Control Options for Automatic Control Valves. Jody Malo Singer Valve
Electronic Control Options for Automatic Control Valves Jody Malo Singer Valve Control Chamber Restriction Manual Ball Valve Inlet Outlet Advantages: No power required Ease of use Been used for 80+ years
More informationMount Pleasant Waterworks. Cross-Connection Control Program Guidelines October 2010
Mount Pleasant Waterworks Cross-Connection Control Program Guidelines October 2010 1 PREFACE The purpose of this policy is to protect the public water supply from the possibility of contamination. The
More information24V, Motorized Actuators
24V, Motorized Actuators AMV 435, 3-point floating Description Main data: Supply voltage: 24 VAC/DC, 50 or 60 Hz Available control input signal versions: -3-point floating Stem travel: 20 mm Selectable
More information8100, 8200, , 8202, 8203, 8204, 8205, 8206
800, 8200, 8300 820, 8202, 8203, 8204, 8205, 8206 W R A, O USA T: 800 32 7950 440 998 2788 F: 440 992 2925... 023208 2 INSTRUCTIONS FOR 3/4,, -/4 DIAMETER TAPS FIGURE A B C D E F G HOT TAP SPINDLE HOT
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationEmech Troubleshoot Guide
Actuator display lights up intermittently, but does not move Is 24 Vdc power supply is adequate? Is 24 Vdc supply stable at actuator terminals? The power supply does not have the required capacity. Review
More informationManual. NanoTron Dual Timer. Installation Maintenance Repair Manual
Manual NanoTron Dual Timer Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com email: support@advantagecontrols.com
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationOld documentation - Only for your information! Product is not available anymore!
Double solenoid valve Control and safety combination valve Servo pressure controller - / 7. Printed in Germany Rösler Druck Edition 0.08 Nr. 09 8 Technical description The DUNGS multiple actuator DMV-SE...
More informationCF-38, CF-80 and CF-100 Gallon Models
COMMERCIAL OIL FIRED REPLACEMENT PARTS LIST CF-38, CF-80 and CF-100 Gallon Models Includes Hydrojet Total Performance System Effective: April, 2007 ECO 7181 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED
More informationFrank Ruiz, Ruiz & Associates Steve Doe, Parker Hannifin Corporation. IFPAC SM Fifteenth International Forum Process Analytical Chemistry SM
Frank Ruiz, Ruiz & Associates Steve Doe, Parker Hannifin Corporation IFPAC SM - 00 Fifteenth International Forum Process Analytical Chemistry SM January -, 00, Amelia Island, Florida, U.S.A Instrumentation
More informationthe circuit breaker for your home plumbing system Intelligent Leak Detection and Water Conservation TM DIRECTIONS FOR USE
the circuit breaker for your home plumbing system Intelligent Leak Detection and Water Conservation TM DIRECTIONS FOR USE Date of Purchase / Installation Installed By Attach receipt here Contents General
More informationERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012
ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,
More informationFlow. Flow. N/en
/ poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated
More informationHigh Purity Laboratory Faucets
High Purity Laboratory Faucets GNF 0 GNF 0 5 /4 5 /4 /2 /2 2 /8 2 /8 Welded ssembly Deck mounted Laboratory Faucet with integral vacuum breaker manufactured Polypropylene per STM D 40 PVDF per STM D 222.
More informationULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES
Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100
More informationDVZ - Vortex Flowmeter and Switch
Measuring Ranges: 0.13-1.2 GPM to 2.7-26 GPM Accuracy: ±2.5 % of F.S. Vortex Shedding Technology with No Moving Parts Ryton Body with Nickel Plated Brass or 316 SS Fittings Outputs: Analog, Frequency,
More informationMaster Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification
SCC Inc. Master Panel Product Description February 15, 2017 The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with
More informationCONTROL BALL VALVES WITH EQUAL PERCENTAGE CHARACTERISTIC 2010 NEW ELECTRICAL ACTUATORS
CONTROL BALL VALVES WITH EQUAL PERCENTAGE CHARACTERISTIC 2010 NEW ELECTRICAL ACTUATORS 2 ACTUATORS Electrical actuators ACTUATORS Electrical actuators FEATURES R2813P00 AC 230V operating voltage, 2-position
More informationWATER TREATMENT SYSTEM CONDUCTIVITY and ph/orp CONTROLLER (With Isolation Kit)
LAKEWOOD INSTRUMENTS MODEL 1512e WATER TREATMENT SYSTEM CONDUCTIVITY and ph/orp CONTROLLER (With Isolation Kit) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road,
More information3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET
-PORT SEAT VALVES PN WITH EXTERNALLY THREADED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In small or medium-sized heating, ventilating and air conditioning plants as a control or safety shutoff valve. For
More informationSSV Special Compensating Bypass Check Valve
V 18-0 pecial Compensating Bypass Check Valve ew - 0 ANI 0-0 Δp V R V pecial Compensating Bypass Check Valve V 18-0 (type with integrated non-return valve in the bypass) Range of Applications Compared
More informationSPCH/ Big bottle blowing block
> > Blowing block for linear and rotating blow moulding machines > > Digital position indicator - counter with four decade from 000.0 to 00.0 > > Best suited for PET bottles from 5 up to 30 litres (up
More informationVALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT
975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT
1/4 to 2 NPT Features Direct mount ISO5211 Full Port 316 stainless steel ball valve 1000 PSI working pressure at 100 F (38 C) Highly visual dome style valve position indicator Rugged aluminum Type 4X weatherproof
More informationPressure Test Pumps. Test Pump. Electric Test Pump. Assembly and Maintenance Test Pumps
Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines and small bore pipelines.
More information2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET
-PORT SEAT VALVES PN WITH FLANGED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In boiler, district heating and refrigeration plants, cooling towers, heating groups, in ventilation and air-handling units as
More informationSignet 2552 Metal Magmeter Flow Sensors
Signet 2552 Metal Magmeter Flow s Features Test certificate included Award winning hot-tap magnetic flow sensor up to DN2550 (102 in.) Patented Magmeter technology* Operating range 0.05 to 10 m/s (0.15
More informationLCP Hybrid Efficient performance with heat pipe technology
LCP Hybrid Efficient performance with heat pipe technology 2 LCP Hybrid The whole is more than the sum of its parts The same is true of "Rittal The System." With this in mind, we have bundled our innovative
More informationIMPAGINATO ing :25 Pagina 1 PRODUCT RANGE
IMPAGINATO ing 5-02-2007 12:25 Pagina 1 PRODUCT RANGE IMPAGINATO ing 5-02-2007 12:25 Pagina 2 MILLIONS OF CUBIC METERS IN 90 YEARS IMPAGINATO ing 5-02-2007 12:25 Pagina 3 YOU CAN COUNT Precision is of
More informationDIN-Rail Mounted Ultrasonic Flow Meter
DIN-Rail Mounted Ultrasonic Flow Meter The ultrasonic flowmeter is a transit-time fixed type flowmeter and can be as ultrasonic heat meter. Its installing way is standard din-rail mounted and have a very
More informationUPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo
UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline
More informationFlow Visualization. Detailed Design Review 2/15/08
Flow Visualization Detailed Design Review 2/15/08 Team Allen Luccitti Kyle Hadcock Mark Bacon Steve Sedensky Topics of Review Customer needs Design specifications Bill of material Pump design Flow loop
More informationLast Update: 1 July Version 3.0. Model # Valve Description - Flushbuy ULTRA & ULTRA Plus List Price
Model # Valve Description - Flushbuy ULTRA & ULTRA Plus List Price U402-1.28-SC-T42 U402-1.6-SC-T42 U402-3-SC-T42 U414-SC-T42 U414-1.28-SC-T42 U414-1.6-SC-T42 U414-3-SC-T42 U451-0.125-SC-T42 U451-0.5-SC-T42
More informationUltrasonic Flow Meter Brochure
Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant
More informationInstruction Manual DR58 Brass Paddle Wheel Flow Meter
Instruction Manual DR58 Brass Paddle Wheel Flow Meter PKP Prozessmesstechnik GmbH Borsigstraße 24 D-65205 Wiesbaden-Nordenstadt Tel.: ++49-(0)6122-7055-0 Fax: ++49-(0)6122-7055-50 Email: info@pkp.de Table
More informationBartels Micropumps. ( ) rev mp6 double actuator micropump. Functional principle of mp6. mp5 smallest available plastic micropump
EN Bartels Micropumps Micropumps transporting the tiniest amounts of gases or liquids can be considered the heart of microfluidics. In many sectors they have become indispensable. Dosing lubricants, feeding
More informationVAREC 2010B/2020B PRESSURE AND VACUUM RELIEF VALVES
VAREC 0B/B PRESSURE AND VACUUM RELIEF VALVES Weight-loaded relief valves that protect tanks from damage or deformation, minimize emissions to the environment and loss of product due to evaporation FEATURES
More informationQ-Flow product information. Variable area flowmeters for gases and liquids
Q-Flow product information Variable area flowmeters for gases and liquids MyScale Air mm ALU Attractive design and price: Variable area flowmeters Q-Flow The proven variable area flowmeter with compact,
More informationPre-installation Manual
Pre-installation Manual Rinse Gum Unit 85-125-165 Pre-installation Manual Rinse Gum Unit 85-125-165 T11018 Edition BA, March 2006 This book has part no 51477 0-2 Introduction Part 0: Introduction This
More informationRemote Process Actuation Control System AirLINE PHOENIX INLINE
Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationPEX Press EN_US_2014_V2.indb 79 2/7/ :15:37 AM
79 For both residential and commercial applications, Viega PEX Press is the trusted way to join PEX tubing. As the world leader in press technology, Viega was the first to offer a press system to the PEX
More informationFrom intermittent water supply to 24/7. Approach and methodology to face water crisis
From intermittent water supply to 24/7. Approach and methodology to face water crisis Alessandro Bettin HITACHI Tirana, 04 October 2016 Hitachi Europe Ltd. 2016. All rights reserved. Segment Constitution*
More informationEverything under control
SAMSON Everything under control SAMSON building automation Ready-configured user interfaces support the user during start-up as well as provide powerful features to control and monitor building facilities.
More informationSpare part catalogue GB 03/2007. Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7
Spare part catalogue 0020037555.03 GB 03/2007 Wall-hung boilers ecotec exclusive 832, 838 VUW 326/4-7 VUW 386/4-7 Content General view of sheet Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing
More informationPressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI
Pressure reducing valve in straightway form NPS 1-6 Pressure reducing valve Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling diaphragm Cast steel Fig. 701 Page
More informationManual Control Unit GFC 32
Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control
More informationDigital electropneumatic Positioner for the integrated mounting on process control valves
Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive
More informationTechnology that makes its mark
Technology that makes its mark KSB EasySelect Guided Tour September 2015 2 List of contents 1. Step by Step to the Right Pump 2. Finding the right valve the easy way 3 Step by Step to the Right Pump (3)
More informationsize size
BE/BE ISO 99/ Valves - Compliance with ISO 99/ international standards - Full range: - - - size - Two different internal commutation system: mixed and spool, appreciated for decades thanks to their maximum
More informationPlumbing Brass Specification Guide
Plumbing Brass Specification Guide www.wattscanada.ca The Dial-ese Cartridge, a Standard in Canadian Plumbing for 0 Years Since its conception in the early 0s, the Dial-ese cartridge has proven to be one
More informationPressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI
Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve ARI-PREDU - ANSI Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling
More informationSafety valves. Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50
Safety valves Safety valves Safety valves for heating, cooling and solar systems, DN 15 DN 50 IMI PNEUMATEX / Accessories and Service / Safety valves Safety valves For the safeguarding of thermostatically
More informationPneumatic Control Unit for the integrated mounting on process valves
Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator
More informationActuators for modulating control AME 55, AME 56
Data sheet Actuators for modulating control AME 55, AME 56 Description Features: Self stroking function Load related Switch off function that prevents overloading Diagnostic LED The actuators are used
More informationB64G - Olympian Plus plug-in system Filter/regulator
BG - Olympian Plus plug-in system > > Port size: /... / (ISO G/PTF) > > High efficiency water removal > > Diaphragm and balanced valve design ensure good regulation characteristics > > on-rising adjusting
More informationUTECHNICAL FEATURES of A6 PANELS for UELECTRIC REMOTE CONTROLLED MONITORS. UGeneral description
UTECHNICAL FEATURES of A6 PANELS for UELECTRIC REMOTE CONTROLLED MONITORS UGeneral description The remote controlled monitors are available with foam/water flow rates from 50 up to 30.000 lt/min. and consequently
More informationRemote Process Actuation Control System AirLINE PHOENIX INLINE
Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility
More informationFxM. ISO7/1 thread, EN331 standard PN40~PN25(5MOP/20MOP) Size:1/4 ~2
BA VAVE - EVER ANDE F/F Model: E0 Advantica british gas, wras, en approved ball valves yellow stainless steel lever handle; FxF ISO/ thread, EN standard PN0~PN(MOP/0MOP) Size:/ ~ According to EN standard.
More informationETV. Electronic Tempering Valve. Installation and Operation Manual. Operates a Modulating Motorized Valve to Regulate Domestic Hot Water Temperature
Installation and Operation Manual Operates a Modulating Motorized Valve to Regulate Domestic Hot Water Temperature Electronic Tempering Valve WARNING This Heat-Timer control is strictly an operating control;
More informationThank you for purchasing one of our products. Please read this manual before using this product. When using this product, always follow the
Thank you for purchasing one of our products. Please read this manual before using this product. When using this product, always follow the instructions contained in this manual, and pay attention to the
More informationJVMG* *NSF 61/Annex G Certification and Compliance with State Codes does not apply to JVMG Models
JVM, JVML SERIES Stainless Steel Construction Closed multi-stage impeller Flow: 4 to 38 GPM Head: to 82 ft. Range of HP: to HP Applications: Commercial booster system, Boiler feed, Jockey, Water Purification,
More informationVS Ultra & VS Integra
B FRONT OF DEVICE C REAR VIEW - SIDE VIEW ACCESSORIES View from above Rear view External battery (optional) D VS Ultra & VS Integra Illustrations Components of the NOT044- System A COMPONENTS (Components
More informationControl Head for the integrated mounting on process valves
Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated
More informationZMICROFLEX-C ULTRASONIC LEVEL TRANSMITTER
ZMICROFLE-C ULTRASONIC LEVEL TRANSMITTER http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 The ultrasonic level indicator is a non-contact, lowcost and easy-to-install
More informationVSG, VSL, VSKH and VSKV Two-line Metering Devices
VSG-KR These high quality, galvanized steel metering devices are designed for high-pressure (up to 400 bar) two-line systems. They can also be used in low to medium-pressure systems. They are available
More informationManual Simatek Control Unit GFC 32
Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections
More informationKitchen Sinks & Bathware
Kitchen Sinks & Bathware Index KITCHEN SINKS /2 FLUSHING CISTERNS 13 SEAT COVERS 16 PTMT BATHROOM WATER TAPS ACCESSORIES 2/ 23 WATER DRAINS 27 About us Prabhat Plastic Industries an ISO 9001:2008 Certified
More informationChemlock PFA and PP Filter Housings
CONTAMINATION CONTROL SOLUTIONS Chemlock PFA and PP Filter Housings Installation and use manual Table of Contents Introduction... 2 Safety... 2 Specifications... 2 PFA... 2 PP... 2 Dimensions... 3 Minimum
More informationCANOpen System Installation manual rev. 3.0
CANOpen System INSTALLATION MANUAL rev. 3.0 page 1 /12 Technical characteristics CANOpen System Installation manual rev. 3.0 SUPPLY VOLTAGE: 24 V ± 10 % WORKING TEMPERATURE: 0 50 C PERCENTAGE OF HUMIDITY:
More informationNew. Products. piezo switches piezo keypads piezo keyboards piezo technology IP68/ip69k/atex Fax:
New Products piezo switches piezo keypads piezo keyboards piezo technology IP68/ip69k/atex 262.652.8660 Fax: 262.652.1388 www.safeworkplace.org Piezo switches Stern s SmartSwitch Piezo switches line, offers
More information4-step Chiller and Heat Pump Controller
4-step Chiller and Heat Pump Controller Technical Data Sheet GENERAL DESCRIPTION MODELS CODE MODEL DESCRIPTION MW324000 ECH 420 HEAT PUMP WITH 4 STEPS/ 2 CIRCUITS + MODBUS MW324005 ECH 420/V WITH SCREW
More information/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual
More informationFCU-MULTI Modbus Fan Coil Unit Controller
Product Sheet CT2.61 Controller Type FCU-MULTI FCU-MULTI Modbus Fan Coil Unit Controller FCU-MULTI is completely stand-alone operating room controller designed for room heating, cooling, ventilation, lighting
More informationElectrical Actuators
4 891 SSB without auxiliary switch SSB1 with auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB31 SSB81 SSB61 SSB31 operating voltage AC 230
More informationVane Pump Series SDV. Fixed Displacement zp14. Catalogue HY0738-A/CH November Hydraulics. Hydraulics
SDV Fixed Displacement zp4 Catalogue HY078-/CH November 004 Contents SDV Introduction General applications instructions... Maximum speed... Pressure ratings... Minimum allowable inlet pressure... General
More informationThe LVS Directional Valve with Digital Pilot Control A New Generation
The LVS Directional Valve with Digital Pilot Control A New Generation Flexible Economical Harmonised Secure motion and progress Harmoniously Combined Hydraulics, Sensors, Electronics Plug and Play No adjustments
More informationElectrical Actuators
4 891 SSB without auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB1 with auxiliary switch SSB31 SSB61 SSB81 SSB31 operating voltage AC 230
More informationLINE UP LINE UP (RT) ( RCUP75AUZ / 50Hz ) Products Series RCUP-AUZ
Hitachi screw chiller unit widely used for air conditioning and industrial purposes Newly released, equipped with a new screw compressor realizing drastic energy saving and great functionality ( RCUP75AUZ
More informationTechnical features. 12/ f. N/en
/, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based
More informationComputer Controlled Pelton Turbine TPC
Computer led Pelton Turbine TPC Technical Teaching Equipment Always included in the supply: SCADA. EDIBON Computer System Teaching Technique used 5 6 2 Interface Box Cables and Accessories Manuals 3 Data
More information