JVMG* *NSF 61/Annex G Certification and Compliance with State Codes does not apply to JVMG Models
|
|
- Lydia Hancock
- 6 years ago
- Views:
Transcription
1 JVM, JVML SERIES Stainless Steel Construction Closed multi-stage impeller Flow: 4 to 38 GPM Head: to 82 ft. Range of HP: to HP Applications: Commercial booster system, Boiler feed, Jockey, Water Purification, Hot Water Applications NSF 61/Annex G Certified Certified California AB 193 Compliant Certified Vermont Act 193 Compliant CONTENTS: JVM, JVM L SPECIFICATIONS R1-3 SELECTION CHART R1- DIMENSIONS R1 17 MODEL No. PERFORMANCE CURVE JVM3 R1-7 JVM R1-8 JVM R1-9 JVM18 R1- JVMG* SPECIFICATIONS R1-4 SELECTION CHART R1- DIMENSIONS R1 21 MODEL No. PERFORMANCE CURVE JVMG32 R1-11 JVMG4 R1-12 JVMG64 R1-13 JVML3 R1-7 JVML R1-8 JVML R1-9 JVML18 R1- JVML32 R1 11 JVML4 R1 12 JVML64 R1 13 *NSF 61/Annex G Certification and Compliance with State Codes does not apply to JVMG Models R1-
2 Standard NEMA motors Integral thrust bearing on HP and larger pumps to handle axial thrust loads Air vent in casing cover allows proper venting preventing air entrapment and dry run Liner ring is a self-aligning, floating design constructed to prevent swelling at high temperatures Tungsten carbide lower pump bearings and sleeves are standard construction for all services, providing maximum operating life Direct drive pump and motor shafts are keyed for positive, reliable power transmission with no adjustments necessary Flexible floating outer casing allows for thermal expansion in hot water applications, preventing deformation due to pressure fluctuations Anti-erosion measures a dish-shaped insert is fitted to the intermediate casing designed to promote smooth flow and prevent high velocity areas that accelerate erosion Square-edge six spline shaft (JVM 3-18) or twelve spline shaft (JVM 32-64) provides positive location and drive of impellers eliminating wear Dimensions & flanges installation is to market accepted dimensions for easy upgrade of existing installations Mechanical seal Silicon/Carbon/Viton mechanical shaft seal Positive Sealing O-rings between intermediate casings provide positive sealing and increased efficiencies Typical Applications Water Supply Reverse Osmosis Water Boosting Washing Systems Fire Fighting Water Treatment Plants Boiler Feed Hot & Cold Water Circulation Irrigation Sprinkler Systems Filtration Heat Exchangers R1-1
3 Models JVM 3,,, 18 JVML 3,,, 18 JVMVM JVML Size ANSI raised face Suction 1 1 /4'' for JVM 3 and 2'' for JVM and 18 ANSI raised face Discharge 1 1 /4'' for JVM 3 and 2'' for JVM and 18 Range of HP 1 /2 to ÿ 1 /2 to 2HP Range of Performance Capacity Head Liquid handled Type of liquid Temperature Working pressure at 34 RPM 4 to 118 GPM 27 to 8 feet 4'' for EVMUG64 Clean water (for other clean liquids, consult factory) to +248 F (- to 1 C) 36 PSI (2 Bar) max. (see page R1-13 for specifics) Materials EVMU EVMUL EVMUG Impeller AISI 4 AISI 316 Intermediate casing AISI 4 AISI 316 Bottom casing AISI 4 AISI 316 Casing cover AISI 4 AISI 316 Outer casing AISI 4 AISI 316 Shaft AISI 316 AISI 316 Liner ring PTFE/AISI 316 Motor bracket Cast iron/4 Cast iron/316 Base Cast iron/4 Cast iron/316 Pump Bearing Sealed ball bearing/tungsten carbide Shaft Seal Mechanical seal Silicon/Carbide/Carbon/FPM (see page R1-14 for construction details) Motor Type Speed Three Phase Direction of Rotation Test standard NEMA C/TC/TSC frame 6 Hz, 34 RPM (2 poles) 8-2/46V Clockwise when viewed from motor end ISO 996 annex A Consult factory for optional motor types R1-2
4 Models JVMG 32, 4, 64 JVMGL 32, 4, 64 Size ANSI raised face Suction 2 1 /2'' for JVM 32 3'' for JVM 4 4'' for JVM 64 Discharge Range of HP Range of Performance Capacity Head Liquid handled Type of liquid Temperature Working pressure ANSI raised face 2 1 /2'' for JVM 32 3'' for JVM 4 4'' for JVM 64 to HP at 34 RPM 66 to 39 GPM 44 to 9 feet Clean water (for other clean liquids, consult factory) to +248 F (- to 1 C) to 4PSI ( Bar) max. (see page R1-13 for specifics) Materials Impeller AISI 4 AISI 316 Intermediate casing AISI 4 AISI 316 Bottom casing Cast iron AISI 316 Casing cover Cast iron AISI 316 Outer casing AISI 4 AISI 316 Shaft AISI 316 AISI 316 Liner ring PTFE/AISI 316 Motor bracket Cast iron Cast iron/316 Base Cast iron Cast iron/316 Pump Bearing Sealed ball bearing/tungsten carbide Shaft Seal Mechanical seal Silicon/Carbide/Carbon/FPM (see page R1- for construction details) Motor Type Speed Three Phase Direction of Rotation Test standard NEMA TC/TSC frame 6 Hz, 34 RPM (2 poles) 8-2/46V Clockwise when viewed from motor end ISO 996 annex A Consult factory for optional motor types R1-3
5 6 Hz, Synchronous Speed 34 RPM Q m 3 /h H ft Q l/min H m 7 JVM 3 JVM JVM JVM 18 JVM 32 JVM 4 JVM 64 US GPM lmp. GPM R1-4
6 JVM 3.HP - HP JVM JVM 3 18 Synchronous Speed: 34 RPM 2# ANSI 1¼'' 4-Bolt R1-
7 JVM.7HP - 7.HP JVM -2 - JVM -16 Synchronous Speed: 34 RPM 2# ANSI 1 1 /4'' 4-Bolt R1-6
8 JVM 1. HP - HP JVM 2 - JVM 16 Synchronous Speed: 34 RPM 2# ANSI 2'' 8-Bolt R1-7
9 JVM 18 HP - 2HP JVM JVM Synchronous Speed: 34 RPM 2# ANSI 2'' 8-Bolt R1-8
10 JVM 32 HP - HP JVM 32 1 JVM RPM # ANSI 2 1 /2'' 4-Bolt JVM 32 JVM RPM # ANSI 2 1 /2'' 8-Bolt 33 H (m) 4 1 H (ft) J VM32-1 HP Min. Flow JVM 32 9 HP J VM HP JVM32 7 HP JVM32 6 2HP 2 JVM32 HP 122 J VM HP 6 91 JVM32 3 HP J VM HP J VM HP 3 JVM32 1 HP NPSH US GPM NPSH (ft) 1. NPSH (m) eff. % Q m 3 /h US GPM Water Temperature: C (68 F) R1-9
11 JVM 4 7.HP - HP JVM JVM 4 3RPM # ANSI 3'' 4-Bolt JVM JVM RPM # ANSI 3'' 8-Bolt 274 H (m) H (ft) 8 J VM4 7-2 HP Min. Flow JVM4 6 HP JVM4 HP 2 J VM4 4-1 HP 122 JVM4 3 2HP 6 91 J VM4 3-2 HP 4. JVM4 2-1 HP 61 JVM4 1 HP JVM HP NPSH NPSH (ft) 3 1. NPSH (m) 2 US GPM eff. % Q m 3 /h 2 US GPM Water Temperature: C (68 F) R1-
12 JVM 64 HP - HP JVM JVM RPM # 4'' ANSI 8-Bolt H (m) H (ft) JVM64 4 HP Min. Flow 2 J VM HP 122 JVM64 3 HP J VM HP 91 JVM64 2 2HP J VM HP 61 6 JVM64 1 HP J VM HP NPSH NPSH (m) US GPM eff. % Q m 3 /h US GPM Water Temperature: C (68 F) R1-11
13 Maximum Working Pressures Model JVM 3 2 JVM 3 9 JVM 2 JVM JVM 2 JVM 8 JVM 18 2 JVM 18 6 JVM 32 1 JVM JVM JVM 4 3 JVM JVM 64 3 JVM 3 11 JVM 3 18 JVM 11 JVM 16 JVM JVM 16 JVM 18 7 JVM JVM 32 JVM JVM JVM JVM JVM 64 4 JVM 32-9 JVM 32-1 Maximum Working Pressure 2 PSI 36 PSI 4 PSI R1-12
14 Mechanical Seal JVM 3,,, 18 JVML 3,,, 18 Mechanical Seal Pump Type Size [inch] Max.working pressure [PSI] d [inch] D 1 [inch] L [inch] L 1 [inch] L 2 [inch] stationary seal ring Carbon graphite Material 2 rotary seal ring Silicon carbide 3 elastomer FPM R1-13
15 Mechanical Seal JVMG 32, 4, 64 JVML 32, 4, 64 working pressure to 36 PSI Standard Seal working pressure to 4 PSI Standard Seal Size (inch) Max. working pressure (psi) 2 d (inch) d1 (inch) d2 (inch) d3 (inch) d4 (inch) 2.47 L1 (inch) L2 (inch) L3 (inch) L4 (inch) L (inch) A stationary seal ring Carbon graphite Material B rotary seal ring Silicon Carbide elastomer FPM R1-14
16 Models JVM(L)3 JVM(L) C* Approximate Motor Dimensions C* for 3 phase, TEFC, NEMA Motors HP Frame Size 6C 6C 6C 143TC 14TC 14TC C* Inches Motor Wt LBS Note: C* may vary slightly by manufacturer Flange Detail: JVM(L) 3 2Lb. ANSI JVM(L) 2Lb. ANSI Refer to page R1-17 for dimension details. R1-
17 Models JVM(L)3 JVM(L) Pump Type EVMU(L) HP Dimensions Motor Frame D D1 D2 D3 H H1 Weight [lbs] C 1 3/8" 2 63/64" 33/64" 6 39/64" 11 /16" 23/32" C 1 3/8" 2 63/64" 33/64" 6 39/64" 12 9/64" 23/32" C 1 3/8" 2 63/64" 33/64" 6 39/64" 12 31/32" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 13 /64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 14 11/16" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 17/32" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 16 23/64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 17 3/16" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 18 27/32" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 19 43/64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 7/64" 23/32" /8" 2 63/64" 33/64" 9 1/16" 22 7/64" 23/32" /8" 2 63/64" 33/64" 9 1/16" 2 3/8" 23/32" C 1 3/8" 2 63/64" 33/64" 6 39/64" 11 7/8" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 13 1/32" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 14 9/64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" /64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 16 23/64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 17 /64" 23/32" TC 1 3/8" 2 63/64" 33/64" 6 39/64" 18 61/64" 23/32". 1 3/8" 2 63/64" 33/64" 9 1/16" 21 33/64" 23/32" /8" 2 63/64" 33/64" 9 1/16" 22 /8" 23/32" /8" 2 63/64" 33/64" 9 1/16" 23 23/32" 23/32" /8" 2 63/64" 33/64" 9 1/16" 2 9/64" 23/32" /8" 2 63/64" 33/64" 9 1/16" 28 /32" 23/32" R1-16
18 Models JVM(L) JVM(L)18 C* Approximate Motor Dimensions C* for 3 phase, TEFC, NEMA Motors HP Frame Size 143TC 14TC 213TC 26TC 284TSC C* Inches Motor Wt LBS Note: C* may vary slightly by manufacturer Flange Detail: EVMU(L) 2Lb. ANSI EVMU(L)18 2Lb. ANSI Refer to page R1-19 for dimension details. R1-17
19 Models JVM(L) JVM(L)18 Pump Type EVMU(L) Motor Dimensions HP Frame D1 D3 H Weight [lbs] TC 4 1/64" 6 39/64" 14 1/64" 23/32" TC 4 1/64" 6 39/64" 13/64" 23/32" TC 4 1/64" 6 39/64" 16 49/64" 23/32" /64" 9 1/16" 18 13/16" 23/32" /64" 9 1/16" " 23/32" /64" 9 1/16" 22 3/8" 23/32" TC 4 1/64" 9 1/16" 24 3/4" 23/32" /64" 9 1/16" 27 7/64" 23/32" /64" 9 1/16" 29 41/64" 23/32" /64" 9 1/16" 32" 23/32" /64" 9 1/16" 9/16" 23/32" /64" 9 1/16" 17 41/64" 23/32" /64" 9 1/16" 19 7/32" 23/32" /64" 9 1/16" 2/32" 23/32" /64" 9 1/16" 22 9/16" 23/32" /64" 9 1/16" 24 9/64" 23/32" /64" 9 1/16" 2 4/64" 23/32" TC 4 1/64" 9 1/16" 28 /64" 23/32" TSC 4 1/64" 11 1/32" 37/64" 23/32" H1 R1-18
20 Models JVML 32 1 JVML JVML JVML 4 3 JVM 32 1 JVM JVM JVM 4 3 Approximate Motor Dimensions C* for 3 phase, TEFC, NEMA Motors HP 7. Frame Size 26TC C* Inches Motor Wt LBS Note: C* may vary slightly by manufacturer C* Flange Detail: EVMU /2" Lb. ANSI EVMU4 3" Lb. ANSI Refer to page R1-23 for dimension details. R1-19
21 Models JVM JVM 64 3 JVML JVML 64 3 Approximate Motor Dimensions C* for 3 phase, TEFC, NEMA Motors HP 2 Frame Size 26TC 284TSC 286TSC C* Inches Motor Wt LBS Note: C* may vary slightly by manufacturer C* Flange Detail: JVM 64 4" Lb. ANSI Refer to page R1-23 for dimension details. R1-
22 Models JVM 32 JVM 32-1 JVM JVM JVM JVM 64 4 JVML 32 JVML 32-1 JVML JVML JVML VML 64 4 Approximate Motor Dimensions C* for 3 phase, TEFC, NEMA Motors HP 2 Frame Size 26TC 284TSC 286TSC 326TSC C* Inches Motor Wt LBS Note: C* may vary slightly by manufacturer C* Flange Detail: JVM 3 2½" Lb. ANSI JVM 4 3 " Lb. ANSI JVM 64 4" Lb. ANSI Refer to page R1-23 for dimension details. R1-21
23 Model Pump Type HP 7 1/ /2 2 2 Weight Lbs Motor Frame* 26TC 284TSC 286TSC 286TSC 26TC 284TSC 286TSC 326TSC 326TSC 26TC 284TSC 286TSC 326TSC PL 18 3/16 19/ / / / / / / / / / / / / / / / / /64 26 / / /4 32 3/ / / /64 H 4 9/64 33/64 33/64 Dimensions (inches) G ST SA SG SF SD SN 4/64 7 2/ /32 2 9/ /64 1 1/16 7 1/2 3/4-UNC 8 /16 7 1/2 2/ /8 3 / / /64 8 1/4 29/ /32 9 2/ /8 3 /16 33/ /64 29/32 Model Pump Type HP 7 1/ /2 2 2 Motor Frame* 26TC 284TSC 286TSC 286TSC 26TC 284TSC 286TSC 326TSC 326TSC 26TC 284TSC 286TSC 326TSC SE 1/2 7/8 6 6 /8 7 1/2 7 7/8 BM 6 11/ / /64 BY1 9 29/64 /32 /32 Dimensions (inches) *Motor frame for Three Phase TEFC only. Consult factory for single phase and alternate enclosures. Bare Pump only. BL 8 17/64 9 7/64 9 7/64 BW 11 1/ / /32 BF 3/64 3/64 3/64 BH 1 3/8 1 49/ /64 R1-22
Standardised EN 733 centrifugal pumps
F Standardised EN 733 centrifugal pumps PERFORMANCE RANGE Flow rate up to l/min (3 m³/h) Head up to 9 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between - C and +9 C Ambient
More information2CP. Centrifugal twin-impeller pumps
CP Centrifugal twin-impeller pumps Clean water Domestic use Civil use Industrial use PERFORMANCE RANGE Flow rate up to l/min (7 m³/h) Head up to m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid
More informationStainless Steel Submersible Pumps DATA BOOKLET. ISO 9001 Company. 60 Hz. Pumping Solution
Stainless Steel Submersible Pumps DATA BOOKET ISO Company Pumping Solution Hz Photographs of a few Manufacturing Units Contents Stainless steel submersible bore well pumps Product data Introduction Operating
More informationHANKIA. DSV type. Single stage,vertical Axially split case double suction pump
DSV type Single stage,vertical Axially split case double suction pump High efficiency and low pulsation Wind performance range with up to 280m head Stable service and low maintenance Heavy duty design
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Seal-less circulator with flanged connection. Two speed, manually adjustable to match
More informationL P Linn-Pumpen GmbH. Submersible Vertical Electric pumps. SVI Series. with high efficiency PLM motors. SVI Series MARKET SECTORS INDUSTRIAL, CIVIL.
Submersible Vertical Electric pumps with high efficiency PLM motors MARKET SECTORS INDUSTRIAL, CIVIL. APPLICATIONS Pumping of coolants, lubrificants and condensate. Machine tools, welders, engine test
More informationClose-coupled centrifugal pumps
CombiBloc Close-coupled centrifugal pumps CombiBloc CombiBloc is the premier solution for pumping clean thin liquids in a very cost-effective way. The pump is part of Johnson Pump s Combi-system, a modular
More informationPUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...
PUMPS FOR INDUSTRY CONTENTS: The Vertical Pump Specialists Introduction & User List Product Overview Vertical Process Pumps... Vertical Sewage Pumps... Series 700 Vertical Sump Pumps... Series 800 Vertical
More informationSERIES 1300 Quality Design Features Assure Long, Trouble-Free Service
SERIES Quality Design Features Assure Long, Trouble-Free Service End Suction WIDE RANGE OF APPLICATIONS: Industrial Process Pollution Control General Pumping Spray Systems Deionized Water Waste Water Clear
More informationASTRO 2 CIRCULATORS. ASTRO 2 3-Speed Circulators (except Astro 286):
DATE: January 30, 015 DATE: January 5, 014 ASTRO 3-Speed Circulators (except Astro 86): ASTRO CIRCULATORS IRON BODY CONSTRUCTION (Includes Check Valve) Model No. Part No. Connection List Price Wt.ea.lbs.
More informationStandard Circulating Pumps
Product review Range: 1 1 3Q [ m³/h] Hz - North America 1 3 1 1 1.x1 1.x x x3 x 1 1 Q [ US gpm] >Single-head pumps: Circulating pumps with flanged connection > Applications: Drinking-water circulation
More informationASTRO CIRCULATORS. IRON BODY CONSTRUCTION Model No. Part No. Connection List Price Wt.ea.lbs. ASTRO
ASTRO CIRCULATORS ASTRO 3 Speed: IRON BODY CONSTRUCTION Model No. Part No. Connection List Price Wt.ea.lbs. ASTRO-30-3 110123-305 Replaced by 110223-305 (Astro 2) ASTRO-50-3 110123-307 Replaced by 110223-307
More informationBARE SHAFT PUMPS AND MOTOR PUMPS
APPLICATIONS Air Conditioning Heating and ventilation Refrigeration Fire protection Plumbing Water Circulation Transfer and Irrigation Pressure Boosting Process Industries Water Treatment and Supply DESIGN
More informationMAX FLUID TEMPERATURE
Centrifugal pumps are designed to transfer both corrosive and non-corrosive fluids at maximum hydraulic efficiencies. Centrifugal pumps are not self-priming and must be used in applications where flooded
More informationVARIABLE SPEED BOOSTER SYSTEMS AURORA INTELLIBOOST WITH INTELLIMANAGER. Distributed by Flow-Tech Industries
AURORA INTELLIBOOST WITH INTELLIMANAGER VARIABLE SPEED BOOSTER SYSTEMS Certified to NSF/ANSI 61-G AURORA INTELLIBOOST Variable Speed Booster System Take A Leap Toward Technology The IntelliBoost Variable
More information4" MULTISTAGE CENTRIFUGAL SUBMERSED PUMPS COMPLETE WITH MOTOR
NOCCHI SCM 4 PLUS Maximum rigidity and resistance to water hammer, Strong resistance to the abrasive action of sand, Excellent hydraulic efficiency SCM 4 PLUS submersible pumps consist of a multi-stage
More informationLenntech BMP GRUNDFOS DATA BOOKLET. High-pressure piston pumps 50/60 Hz
Lenntech GRUNDFOS DATA BOOKLET BMP High-pressure piston pumps 50/60 Hz Contents Product data Introduction Page 3 Features and benefits Page 3 Applications Page 3 Pumped liquids Page 3 key Page 4 Motor
More informationE SERIES CIRCULATORS
E SERIES CIRCULATORS CAST IRON BODY CONSTRUCTION BRONZE BODY CONSTRUCTION Part No. Part No. Model 120V Motor 240V Motor List Price Wt (lbs) Model 120V Motor 240V Motor List Price Wt (lbs) E7 180200-643
More informationSubmersible Pumps. Pumping Solution. 50 Hz
Submersible Pumps Pumping Solution 0 Hz INTRODUCTION Submersible bore well pumps for (DN 0 mm), (DN 0 mm), (DN 0 mm), (DN 00mm), (DN 0 mm) and (DN 00 mm) wells. Sized for connection to the motor according
More informationCR, CRN high pressure
GRUNDFOS PRODUCT GUIDE CR, CRN high pressure Vertical multistage centrifugal pumps 6 z Contents Mission 3 Product overview Performance range Product range 5 Applications 6 CRNE 1 and 3 S 7 CRN 5, 1, 15,
More information4W 50Hz 2900 RPM Noryl Pump
50Hz Noryl Pump DCODE Identification system for Pump x x x xxx x x xx Example :- No of Stage Design No Frequency 50= A /60=B Meter 3 / Hour Mix Flow / Radial Flow Material A=AISI316, B=AISI304 C=Bronze,
More informationRA /2.95. Gear Pump Model G2 (Series 4X) For Flange Mounting with SAE threaded Ports. Functional description. Symbols
/2.9 Gear Pump Model G2 (Series X For Flange Mounting with SE threaded Ports s to 22... 6 PSI (2 bar....7 in /rev. (22. cm /rev. /2.9 eplaces: 2.92 New principle of sealing the pump body, increases service
More informationCR, CRN high pressure
GRUNDFOS DATA BOOKLET CR, CRN high pressure Vertical multistage centrifugal pumps 5/6 Hz Contents Product Data Performance range 3 Product range 4 Applications 4 CRNE 1 and 3 HS 5 CRN 5, 1, 15, SF 6 x
More informationSUBMERSIBLE VERTICAL ELECTRIC PUMPS SVI SERIES
SUBMERSIBLE VERTICAL ELECTRIC PUMPS SVI SERIES EDIZIONE 09-99 ISO 9001 (UNI - EN 29001) Lowara has obtained top level Quality System certification for the following production plants: Montecchio Maggiore
More informationshop online:
Process systems Liquid ring vacuum pumps Single stage pumps 8 Alpha series single stage liquid ring vacuum pumps 9 AL series single stage liquid ring vacuum pumps 97 Two stage pumps 00 SHR series liquid
More informationSpectrum 175D. meter performance with no maintenance.
The Spectrum Single-Jet Meter is the widest range, single measuring element meter available to U.S. utilities. They have been designed to replace maintenance-intensive compound meters and limited range
More information8 Submersible Motors Hi-Temp 75
Applications These motors are built for dependable operation in vertical 8 diameter or larger wells, in applications with higher temperature, higher thrust or low flow. Basic Features Able to operate in
More informationCR, CRI, CRN, CRE, CRIE, CRNE
GRUNDFOS PRODUCT GUIDE CR, CRI, CRN, CRE, CRIE, CRNE Vertical multistage centrifugal pumps 6 z Contents Mission Product data Introduction 4 Product range 6 Applications 8 Pump 9 Motor 9 Terminal box positions
More informationProduct Overview. Product Overview. How To Order. Flange Input - Shaft Output Right Hand Output. Flange Input - Shaft Output.
Product Overview Product Overview Flange Input - Shaft Right Hand Flange Input - Shaft Double End Shaft Input - Shaft Left Hand How To Order 5:1-60:1 ratios sizes 1.33-3.25 One piece # Fc20 all cast iron
More informationFB-Hygia.book Page 1 Monday, June 21, :58 PM GRUNDFOS PRODUCT GUIDE. Sanitary pumps. Centrifugal pumps 60 Hz
FB-ygia.book Page Monday, June, : PM GRUNDFOS PRODUCT GUIDE Sanitary pumps FB Centrifugal pumps z FB-ygia.book Page Monday, June, : PM Contents Mission Mission Introduction Grundfos sanitary pumps ygienic
More information8 Submersible Motors Standard
Applications These motors are built for dependable operation in vertical 8 diameter or larger water wells. Basic Features Double Flanged NEMA mounting design Stainless steel splined shaft StatorShield
More informationZMD ZMDV. AXIALLY SPLIT, ONE-STAGE, BETWEEN-BEARINGS PUMPS 50/60 Hz. High reliability and efficiency. Wide range of material options
AXIALLY SPLIT, ONE-STAGE, BETWEEN-BEARINGS PUMPS 0/ Hz ZMD ZMDV High reliability and efficiency Wide range of material options Excellent suction capability due to low NPSH Simple installation and maintenance
More informationSpectrum 130D. Warranty 5 Yr. Materials & Workmanship 5 Yr. OER Register Standards AWWA C NSF-61/372
The Spectrum Single-Jet Meter is the widest range, single measuring element meter available to U.S. utilities. They have been designed to replace limited range displacement meters. The Spectrum meters
More informationFEATURES APPLICATIONS OPERATING DATA MATERIALS OF CONSTRUCTION. Flood control
APPLICATIONS FEATURES Flood control Irrigation Land drainage Pollution control Industry Water refineries Water parks Design OPERATING DATA Capacity:...up to.000 m/h Head:...up to m Max. water temperature:...0
More informationimag-series Flanged Magmeter
s Flow Meters & Controls imag-series o M o vi n g P a r t N FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved (3 only) IP68 rated 9001:2008 ISO
More informationSpectrum 500D 3/4 gpm Functional Specifications Physical Specifications Standards Spectrum 500D (3 or 4 )
The Spectrum Single-Jet Meter is the widest ranged, single measuring element meter available to U.S. utilities. They have been designed to replace maintenance-intensive compound meters and limited range
More informationJVB VERTICAL MULTISTAGE IN-LINE PUMPS FULL STAINLESS STELL. 50 Hz POMPE VERTICALI IN-LINE COMPLETAMENTE IN ACCIAIO INOX
JVB VERTICAL MULTISTAGE IN-LINE PUMPS FULL STAINLESS STELL Hz JMS ELETTROPOMPE S.R.L. POMPE VERTICALI IN-LINE COMPLETAMENTE IN ACCIAIO INOX VERTICAL MULTISTAGE IN-LINE PUMPS FULL STAINLESS STEEL POMPE
More informationHM, HMC, HMN. Horizontal Multistage Centrifugal Pump, 60Hz
HM, HMC, HMN Horizontal Multistage Centrifugal Pump, 60Hz Approvals CERTIFICATE IQNet and SQS hereby certify that the organization Swiss Pump Company AG CH-3645 Thun-Gwatt Certified area Whole company
More informationimag 4700 Series FLANGED MAGMETER
p r (Remote Display) RIGHT METER FOR Water & Wastewater Treatment Municipal Pump skids Pump stations Packaged plants Filtration systems Reclaimed water Hydraulic fracturing -300 Features Easy setup Minimal
More informationEasy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI
Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,
More informationSpectrum 50DL. Warranty 5 Yr. Materials & Workmanship 5 Yr. OER Register. Standards AWWA C NSF-61/372. Spectrum 50DL (1 )
The Spectrum Single-Jet Meter is the widest ranged, single measuring element meter available to U.S. utilities. They have been designed to replace limited range displacement meters. The Spectrum meters
More informationVane Pump Series SDV. Fixed Displacement zp14. Catalogue HY0738-A/CH November Hydraulics. Hydraulics
SDV Fixed Displacement zp4 Catalogue HY078-/CH November 004 Contents SDV Introduction General applications instructions... Maximum speed... Pressure ratings... Minimum allowable inlet pressure... General
More informationPump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018
Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018 Tags: P-8 1800RPM Premium Efficient Motor 460/3/60 Pump and Motor Weight: 183lbs
More informationLCC Pump Series - Wear Resistant, High Performance Slurry Pumps
LCC Pump Series - Wear Resistant, High Performance Slurry Pumps 02 LCC Pump Series Solutions for the most Abrasive and Corrosive Slurry Applications With High Performance Wear Resistance, the GIW Minerals
More informationShaft Seal. Accessories
Type series booklet Hz.5/- G Standardized Pumps Fields of Application Water supply Sprinkling Irrigation Drainage Air-conditioning Drinking water Waste water Cooling water Fluid Pure liquids not chemically
More informationTD End-Suction Pumps. Operating data Flow rates up to 300 l/sec Head up to 160 metres Temperature 20 0 C to C
TD End-Suction Pumps One of the broadest ranges of pumps available from any British manufacturer, with discharge sizes from mm to 0 mm. Widest choice of materials of construction and options to suit many
More informationCompact Bellows Pumps
Compact Bellows Pumps Compact Bellows Metering Pumps were specifically designed for metering applications requiring low discharge pressures. Compact pumps have been successfully applied in photo, X-ray
More informationSUBMERSIBLE PUMPS SEWAGE RANGE
OPERATING LIMITS Flow rates up to: 00 m /h Head up to: 0 m CL Liquid temperature range: + to 0 C* Density of liquid:.0 max. ph of liquid: - Max. immersion depth: 0 m Max. particle size: Ø 0-0 mm ND discharge
More informationMAG. ECO FLO imag Series NSF FEATURES
Flow Meters & Controls MAG ECO FLO imag Series M o vi n g P s N o rt w U NSF o n Easy setup Minimal straight pipe Mounted or remote rate & total 4-2mA output available Tamper-evident seal NSF-61 approved
More information2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET
-PORT SEAT VALVES PN WITH FLANGED CONNECTIONS STAZ-, STBZ-, STCZ- DATASHEET In boiler, district heating and refrigeration plants, cooling towers, heating groups, in ventilation and air-handling units as
More informationFEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated
s Flow Meters & Controls ECO FLOMAG i M A G S e r i e s o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal
More informationKVC / KVCX GENERAL DATA. motralec VERTICAL MULTISTAGE PUMPS
/ X VERTICL MULTISTGE PUMPS motralec rue Lavoisier. Z Lavoisier. ERBLY CEDEX Tel. :... / Fax. :... Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com X GENERL DT pplications Vertical
More informationFEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated
s Flow Meters & Controls ECO FLOMAG imag Series o M o vi n g P a r t N NSF Certified to NSF/ANSI 61 FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved
More informationimag 4700 Series FLANGED MAGMETER
r (Remote Display) RIGHT METER FOR Water & Wastewater Treatment Municipal Pump skids Pump stations Packaged plants Filtration systems Reclaimed water Hydraulic fracturing Features Easy setup Minimal straight
More informationModel RFM. Model RFM. Materials and Specifications. Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" Features 1" RFM 50 2" RFM 160
Residential Fire Meter Sizes 3/4", 1", 11/2" and 2" Features APPLICATIONS: The Hersey Residential Fire Meter (RFM) is specifically designed for use in residential fire protection systems or combination
More informationIMMERSON S6. SUBMERGED BOREHOLE PUMPS Domestic - Agriculture - Industry 50 Hz OPERATING RANGES APPLICATIONS ADVANTAGES. Certified
OPERATING RANGES Flow rates of up to: 7 m 3 /h Manometric heads of up to : m Max. water temperature: + 3 C Max. sand content: 5 g/m 3 DN of delivery port : G / to G3 IMMERSON S-S SUBMERGED BOREOE PUMPS
More informationAG3000 SERIES FLANGED MAGMETER
SERIES p Precision Flow Measurement An ONICON Brand RIGHT METER FOR Irrigation Chemigation Agricultural automation Well usage monitoring Dairy lagoons Features 5 5-YEAR WARRANTY LONGEST IN THE IRRIGATION
More informationL P Linn-Pumpen GmbH. Electric-gear-pumps series FKM
Electric-gear-pumps series FKM Construction Self-priming electric-gear-pumps, bellhousing with foot-flange, pump-casing in cast iron. Gear-pumps series FKM with motor-power up to 1,5. Suction- and -ports
More informationStandard Bellows Metering Pumps
Standard Bellows Metering Pumps Bellows Metering Pumps operate on a positive displacement principle. Pumps are designed to displace both corrosive and noncorrosive fluids. Accurate to ± 0.5% from stroke
More informationTB-mag Pump Series Sales Guide
WWW.INNOMAG.COM Page 1 of 65 TB-mag Pump Series Sales Guide Thrust Balanced, Sealless, Mag-drive pumps Page 2 of 65 # Document Description Page # 1 Pump Specification & Features 3 2 Thrust Balancing 6
More informationTechnical Specification _5.0. Concertor N/EA/DP
Technical Specification 886_. Concertor N/EA/DP Table of Contents Table of Contents System Description.... System overview..... Concertor N..... Concertor EA..... Concertor DP... Product Description...6.
More informationMini Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:
Mini Bellows Pumps Mini Bellows models are ideal for low flow, low pressure metering applications. The pump is constructed entirely of plastic and utilizes GRI s time-proven bellows technology to provide
More informationPACO PUMPS PACO INACTIVE MODELS DRY PIT NON-CLOG REPLACEMENT PARTS GUIDE TYPES NCF, NCP, NCH, NCVU & NCU WITH 5-DIGIT MODEL NUMBERS. D2b.
PACO INACTIVE MODELS DRY PIT NON-CLOG REPLACEMENT PARTS GUIDE TYPES NCF, NCP, NCH, NCVU & NCU WITH 5-DIGIT MODEL NUMBERS PACO CAT#: STOCK#: SER#: PACO GPM: TDH: IMP. DIA. 34014412 While PACO Dry Pit Non-Clog
More informationA3b.2 September, 2014 Supercedes October, 2013 INLINE CENTRIFUGAL PUMPS REPLACEMENT PARTS GUIDE VL, VLC, VLS, VLSC
INLINE CENTRIFUGAL PUMPS REPLACEMENT PARTS GUIDE VL, VLC, VLS, VLSC This guide is valid for all PACO brand products beginning with product codes 16, 17 and Grundfos prodcut codes 26 and 27 only. See back
More informationLenntech GRUNDFOS DATA BOOKLET. CME 10. Horizontal, multistage centrifugal pumps 50/60 Hz
Lenntech info@lenntech.com www.lenntech.com GRUNDFOS DATA BOOKLET CME 1 Horizontal, multistage centrifugal pumps 5/6 Hz General description CME Stainless-steel version Fig. 2 Grundfos CME pumps Cast-iron
More informationVESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS)
VESSEL FUEL MEASUREMENT & MANAGEMENT SYSTEM (VFMMS) Reference: - June 2012 Kral Fuel Flowmeters History: TECHNICAL APPROACH The Kral Flowmeter was developed over 20 years ago a solution to an internal
More informationFrame, End Brackets, & Conduit Box With Heavy Gauge Steel Fanguard and Non-sparking Fan, for Severe
W Series 143T-447T - TEFC Heavy Duty Construction Frame, End Brackets, & Conduit Box With Heavy Gauge Steel Fanguard and Non-sparking Fan, for Severe Single Phase 56/56C : RF - Removable Feet TM - Thermistors
More informationVonk Choke Valve. Flow Control. Features and benefits. Product overview. Technical data. General applications. Model YCV (Y-Type body)
Flow Control Vonk choke valves provide superior performance in abrasive environments, precise flow control and ease of maintenance, delivering operational reliability in the most challenging applications.
More informationNDP-50 Series Specifications
NDP-50 Series Specifications Port Dimensions Intake & discharge connection: Polypropylene (PPG) 2 50mm DIN DN80 PN10 Kynar (PVDF) 2 50mm DIN DN80 PN10 Aluminum (ADC-12) 2 50mm DIN DN80 PN10 (with tapped
More informationMAGFLO MAG 5100 W Benefits Application Flow Measurement Mode of operation Function Integration
Benefits N5 to N2000 (½" to 78") Connection flanges NSI and Ebonite Hard Rubber liner for all water applications EPM liner with drinking water approvals Hastelloy Integrated grounding and measuring electrodes
More information"PVL" SERIES. Fixed Displacement - Single PVL1. Up to 5 MPa (730 PSI), 10.6 cm /rev (.647 CU.IN./rev)
"PVL" SERIES Fixed Displacement - Single PVL Up to 5 (70 ), cm /rev (7 CU.IN./rev) Pub. EC-0 The PVL series single pumps are designed for use with small size machine tools requiring comparatively low pressure
More informationData is only for informational purpose. All specifications are subject to change without notice.
MV Data is only for informational purpose. All specifications are subject to change without notice. 1 First in knife gate 2018-12-19 solutions issue 24 Knife gate valve MV Stafsjö s knife gate valve MV
More informationDewatering pumps for raw water pumping GRUNDFOS DW RANGE. Dewatering pump kw
Dewatering pumps for raw water pumping GRUNDFOS DW RANGE Dewatering pump 0.7-20 kw efficient state-of-art dewatering pumps Unique user benefits The Grundfos DW pumps form part of a complete range of wastewater
More informationType Electrically Actuated 3-way Ball Valves
GF Piping Systems Electrically Actuated 3-way Ball Valves Type 167-17 General Size: ⅜ 2 aterial: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPD, FP End Connection: Solvent
More informationNSF/ANSI 61 Drinking Water System Components - Health Effects
Page 1 of 7 The Public Health and Safety Organization NSF Product and Service Listings These NSF Official Listings are current as of Monday, September 19, 2016 at 12:15 a.m. Eastern Time. Please contact
More informationUPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo
UPGRADE PROGRAM V250 Series Pumps vs V301 Series Pumps Technical Memo INDEX Outline drawings ISO100 3 Outline Drawing CFF6 5 Technical Specification 7 Notes 8 Accessories 8 Controller comparison 9 Outline
More informationIC Series Constant Pressure Inverter Control System
I Series onstant Pressure Inverter ontrol System racsystems PUMP ISO 0 ertified Explanation pplications: Suitable liquids: pplication onditions: Product Features: ode: Optional order: Installation Precautions
More informationData sheet: Wilo-Stratos 40/1-8
Data sheet: Wilo-Stratos 4/1-8 Pump curves 1 2 v 3 4 DN4 m/s,5 1, 1,5 2, 2,5 DN5 H/m Wilo-Stratos 4/1-8 p/kpa Wilo-Stratos 5/1-8 48 1 /min - 1 V 1~23 V - DN 4 / DN 5 8 8 P 1/W n= const 6 383 1 /min - 8
More informationTaylor Valve Technology, Inc
MULTI-ORIFICE VALVE MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JUL0-TVT-OKC SERIES
More informationVAREC 5000/5010 SERIES FLAME ARRESTERS
VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL
More informationData sheet: Wilo-Stratos 50/1-9
Data sheet: Wilo-Stratos 5/1-9 Pump curves H/m 2 5 1 15 2 1 v 1 2 3 1 41 1 /min-1 V 8 3714 1 /min-9 V 3329 1 /min-8 V 6 4 57 1 /min-6 V 2 4 6 P 1/W n= const 4 8 V 2 H/m 2943 1 /min-7 V 2171 1 /min-5 V
More informationBC 35 DOUBLE-CHANNEL. Submersible pumps. PERFORMANCE RANGE Flow rate up to 1900 l/min (114 m3/h) Head up to 31 m
BC 5 Suersile pups DOUBLE-CHANNEL Sewage water Civil use Industrial use PERFORMANCE RANGE Flow rate up to 900 ( /h) Head up to APPLICATION LIMITS 0 axiu iersion depth (with a sufficiently long power cale)
More informationData sheet: Wilo-Stratos 50/1-10
Data sheet: Wilo-Stratos 5/1-1 Pump curves v,4,8 1,2 1,6 2, 2,4DN 4 m/s,4,8 1,2 DN 5 H/m p/kpa Wilo-Stratos 4/1-1 445 1 /min - 1 V Wilo-Stratos 5/1-1 1 1~23 V - DN 4, DN 5 8 P 1/W n= const 6 314 1 /min
More informationLoader Directional Control Valve
Engineering & Manufacturing Solutions Specifications: 10 gpm (38 lpm) Nominal Capacity Rated up to 4000 psi (275 bar) Port Sizes: - Inlet/Outlet #8 SAE - Work Ports #6 or #8 SAE Weighs 10.9 lbs. (4.9 kg)
More informationCLAMSHELL PIPE CUTTING AND BEVELLING MACHINES. Mactech Europe LTD
CLAMSHELL PIPE CUTTING AND BEVELLING MACHINES Mactech Europe LTD Mactech s Clamshell lathes are portable pipe cutting machines designed for on-site precision severing, severing/beveling, and severing/double
More informationAir Moving Solutions. axipal adjustable pitch airfoil fans
Air Moving Solutions. axipal adjustable pitch airfoil fans ATAD ATAB CATALOG AX210 December 2012 AdjustablePitch Models ATAD ATAB Model ATAD Arrangement 4 - Direct Drive The ATAD Adjustable Pitch Airfoil
More informationData sheet: Wilo-Stratos 30/1-8
Data sheet: Wilo-Stratos 3/1-8 Pump curves 7 337 1 /min - 9 V 6 34 1 /min - 8 V 5 271 4 1 /min - 7 V 239 1 /min - 6 V 3 26 1 /min - 5 V 2 173 1 /min - 4 V 14 1 1 /min - 3 V 2 4 6 8,5 1, 1,5 2, 2,5 Q/l/s
More informationTaylor Valve Technology, Inc
MULTI-ORIFICE VALVE Taylor Valve MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JAN00-TVT-OKC
More informationHigh Voltage Induction Motors. 21-MII Series. New High Efficiency Design for High Capacity Applications Up to 3,550 kw (4,750 HP)
High Voltage Induction Motors -MII Series New High Efficiency Design for High Capacity Applications Up to,0 kw (,0 HP) MII Series: Combining over 00 years of experience with innovative new technology makes
More informationNDP-20 Series Specifications
NDP-20 Series Specifications Port Dimensions Intake & discharge connection: Polypropylene (PPG) 3/4 20 mm Female BSPT Aluminum (ADC-12) 3/4 20 mm Female BSPT Stainless Steel (316) 3/4 20 mm Female BSPT
More informationAxially Split Volute Casing Pump RDLO / RDLO V. Type Series Booklet
xially Split Volute Casing Pump RDLO / RDLO V Type Series ooklet Legal information/copyright Type Series ooklet RDLO / RDLO V ll rights reserved. The contents provided herein must neither be distributed,
More informationCatalog 1402
farm DUTY Catalog 0 WWW.PEMSMOTORS.COM Note Key 0 0 0.0 Service Factor / x / Shaft / x / Shaft.0 Service Factor / x / Shaft / x / Shaft / x Shaft 0- HP Volt Tap Off Main Winding to Power Gear Drive Unit
More informationPRIMING-ASSISTED. GRpumps.com
G O R M A N - R U P P P U M P S PUMPS FOR CONSTRUCTION PRIMING-ASSISTED GRpumps.com P R I M I N G - A S S I S T E D P U M P S GORMAN-RUPP SETS A WHOLE NEW STANDARD IN PRIMING-ASSISTED PERFORMANCE Gorman-Rupp,
More informationThe 5400A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel.
Varec 00A Series The 00A Series, Group D, end-of-line flame arrester is designed to prevent the propagation of flames into a storage vessel. Introduction Varec s have been the industry standard for over
More informationMC Series Drives. Flexible, simple, rugged, robust!
Drives Flexible, simple, rugged, robust! Our promise Commitment to Price Leadership Price leadership is serious business. It takes continuous life cycle management to make price leadership a sustainable
More informationYour Clean Air Source!
In-Line Centrifugal Fans Your Clean Air Source! CENTRIFAN IN-LINE CENTRIFUGAL FAN HIGH QUALITY... HIGH EFFICIENCY... VERSATILITY CENTRIFAN IN-LINE CENTRIFUGAL FANS INDEX Centrifan Brochure Index..................
More informationDrawing on 40 years of
Systems Drawing on 40 years of blower and manufacturing experience, Republic Blower Systems are designed to outperform any blower on the market. Providing the ideal combination of powerful air movement,
More informationAssembly and Maintenance
Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines
More informationGRUNDFOS DATA BOOKLET. Dewatering pumps 50 Hz
GRUNDFOS DATA BOOKLET Dewatering pumps 50 Hz Table of contents 1. Introduction 3 Applications 3 Pumped liquids 3 Constructional features 3 2. Identification 5 Type key 5 3. Selection of pump Ordering a
More informationOptical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:
SERVO-TEK SERVO-TEK PRODUCTS COMPANY, INC. Optical Encoders www.servotek.com Toll Free Phone: 877-378-0240 sales@servo2go.com RC-800 Summary Hollow Shaft Encoders ST50 Series High Performance Rotary Incremental
More information