Content 1 Generally Installation...3

Size: px
Start display at page:

Download "Content 1 Generally Installation...3"

Transcription

1 Content 1 Generally Installation ETS App Documentation and sample project User interface XLSX-Excel-Template General Mass operation Errors during editing Excel template Common column description of all sheets Sheet Gateways Sheet DALI Lines Sheet DALI Groups Sheet ECGs Sheet Group addresses CSV file Import Messages Wrong device type selected Data not valid with this conditions Data out of range Address already in use Specialty of ETS Appendix Column names of XLSX file Sheet Gateways Sheet DALI Lines Sheet DALI Groups Sheet ECGs Sheet Group addresses CSV file and sheet ECGs field names Siemens AG DS01 1 / 28 Control Products and Systems Siemens AG

2 This ETS App enables the user to import data of a file to ETS to add configured KNX/DALI Gateways into a project. It is possible to import a Excel file or a CSV file. Create XLSX / CSV file Import Data ETS App add KNX/DALI Gateway ETS Commisioning KNX/DALI Gateway Limitations: - no data can be exported, only import is possible. - there is only a limited check of data inconsistency. - copy of cells within excel is only possible in columns - after importing in ETS parameters must be checked before download to the device. 1 General The ETS App is useful for the following devices: N141/03 03 : KNX/DALI Gateway plus N 141/03 5WG AB03 Application program N141/21 03 : KNX/DALI Gateway Twin plus N 141/21 5WG AB21 Application program N141/31 03 : KNX/DALI Gateway Twin N 141/31 5WG AB31 Application program The following procedure is recommended: Install ETS App Import of manually or software-based created CSV file or Create Excel template for the selected unit Edit Excel file according to project requirements Import Excel file Optionally edit additional parameters of the devices Requirements Current version of ETS4.2 or ETS5 is installed. The product databases of all devices are imported. Installation of Microsoft Excel 2007 or higher te about ETS5 The ETS App is also useful for ETS5, but there is an additional procedure necessary, see chapter 7.5. In the following description knowledge is required in - ETS4.2 / ETS5 ( ) - Product family KNX/DALI Gateway (look at. Documentation: 2 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

3 2 Installation 2.1 ETS App The ETS App KNX/DALI Gateway Data Import is available in KNX Onlineshop ( and can be installed and licensed according to ETS manual. Figure 2-1 In ETS installed ETS App Only within a ETS project the App can be started using Tools -> Siemens -> KNX/DALI Gateway Data Import or the menu bar 2.2 Documentation and sample project Figure 2-2 Startup Additional to ETS App itself this documentation and samples of xlsx and csv files are available. Siemens AG DS01 3 / 28 Control Products and Systems Siemens AG

4 3 User interface 1 2 Figure 3-1 User interface 1 Messages Status information and error messages are listed here. These can be stored with Save to file or Copy to clipboard for documentation reasons. 2 Import This area is useful for the following commands: Device type Create XLSX-Template Import XLSX-Data Import CSV-Data Save sample import file Selection of the correct device incl. application version Here an Excel template will be created according to the selected device type for a later import as XLSX file. The file will be created in the current user language of the ETS. If the ETS language is not supported, a English template will be created. Using this command edited xlsx files can be imported. For this import user languages must match. Optionally it is possible to import a CSV-file, which was created manually or by external software tools e.g. CAD tools. This command saves an example of a XLSX and a CSV file for an easy startup. The XLSX Template contains all structures and data, which are necessary for a later import. More information are described in chapter 4 XLSX-Excel-Template in detail. 4 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

5 4 XLSX-Excel-Template 4.1 General The Excel Template is structured in several sheet: te: Gateways DALI Lines DALI Groups ECGs Group addresses Either the name of the sheet nor the column of the XLSX-template must not be edited or changed because they match to the ETS-Plug-In parameter descriptions of the KNX/DALI Gateway. The input format of parameter is equal to the displayed format in the plug-in. If no parameter in filled into a cell the default value will be used. A device will be added, if it is referred in a sheet. A device will always be added to the project. The device must be imported to ETS4 catalogue or once be imported in an ETS5 project. A detailed list of all columns in all sheets including range of values, default values and dependencies are described in chapter Fehler! Verweisquelle konnte nicht gefunden werden Mass operation Microsoft Excel as editing software can be easily used for mass operations (like auto fill, copy-paste, ) for more than one identical parameterized devices. 4.3 Errors during editing Excel template Some errors of parameters will be displayed during editing the excel template. If a parameter value is out of range an excel message will inform you. 4.4 Common column description of all sheets Column - Gateway Here is the individual address: Format If the address is already used, the device will be added with the next free address. Column Group addresses You can use 2- and 3-level group addresses. The free structure is not supported. The configuration in ETS (2-oder 3-level) is not important. Siemens AG DS01 5 / 28 Control Products and Systems Siemens AG

6 The complete address range (16 bit) can be used. Valid group addresses are 1/2/3 and 1/24. The first group address (GA) is the sending. More GA must be separated with : (colon) or (space). Column with predefined values Only values within the dropdown menu can are supported. It is recommended to select from the dropdown instead of typing the value. Figure 4-1 Dropdown for predefined values 4.5 Sheet Gateways Column description Description Gateway Format If no individual address will be entered here, it will be ignored. Gateway Name Name of the gateway Description Description of the device Additional columns see Figure 4-2 ETS-PlugIn Parameter view General 6 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

7 4.6 Sheet DALI Lines Figure 4-2 ETS-PlugIn Parameter view General Column description Description Gateway Format If no individual address will be entered here, it will be ignored. DALI Line A or B is mandatory. For N 141/03 A is mandatory. A is equal to use as 1, B is equal to 2. Modus DALI Line Select here the channel mode of the DALI Line. In case of broadcast additional columns must be noticed. Additional columns See Figure 4-3 ETS-PlugIn Parameter view Channel A: channel mode Broadcast Siemens AG DS01 7 / 28 Control Products and Systems Siemens AG

8 Figure 4-3 ETS-PlugIn Parameter view Channel A: channel mode Broadcast 4.7 Sheet DALI Groups Column description Description Gateway Format If no individual address will be entered here, it will be ignored. DALI Line A or B is mandatory. For N 141/03 A is mandatory. A is equal to use as 1, B is equal to 2. DALI Group Edit here the name for the DALI group, which must be unique within the DALI line. Additional columns See Figure 4-4 ETS-PlugIn Parameter view Group 1 8 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

9 4.8 Sheet ECGs Figure 4-4 ETS-PlugIn Parameter view Group 1 Column description Description Gateway Format If no individual address will be entered here, it will be ignored. DALI Line A or B is mandatory. For N 141/03 A is mandatory. A is equal to use as 1, B is equal to 2. DALI Group Edit here the name for the DALI group, which must be unique within the DALI line. ECG Name Edit here the name of the ECG, which must be unique within the DALI line. Siemens AG DS01 9 / 28 Control Products and Systems Siemens AG

10 Column description Selection of type Additional columns Description 8 types of DALI norm are supported: 0 - Fluorescent lamps 1 - Self-contained emergency lighting 2 - Discharge lamps 3 - Low voltage halogen lamps 4 - Incandescent lamps (dimmer) 5-10V converter 6 - LED modules 7 - Switching function see Figure 4-5 ETS-Plug-in Parameter view ECG device parameter und Figure 4-6 ETS-Plug-in Parameter view ECG Dimming behavior To select a type for a ECG add a x to the corresponding column. The gateway N 141/31 supports no single ECG control, therefore add no ECG specific parameters. Figure 4-5 ETS-Plug-in Parameter view ECG device parameter 10 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

11 4.9 Sheet Group addresses With this sheet group addresses can be predefined: Figure 4-6 ETS-Plug-in Parameter view ECG Dimming behavior Column description Group address Name Group address Description group address Comment group address Description Use 2 and 3 level group addresses. You can use the full range of the addressing room (16 Bit). Valid address formats are 1/12 and 1/2/3. Name for the group address Description for the group address Comment for the group address 5 CSV file The CSV file contains only the sheet ECG of the XLSX template with the assignments to groups, channels and devices. The structure and content matches to the description of chapter 4.8 Sheet ECGs. The CSV file must have a headline with field descriptions, which matches to the column names of sheet ECGs and so to the ETS Plug-In names. Those must not be edited or changed. Siemens AG DS01 11 / 28 Control Products and Systems Siemens AG

12 HINWEIS: The input format of parameter is equal to the displayed format in the plug-in. If no parameter is filled into a cell the default value will be used. Through a CSV Import no general parameters and group addresses for the device and the channel or a group can be edited all parameter keep its default value. These configurations must be edited in ETS after the import and before of a download. A detailed list of all columns in all sheets including range of values, default values and dependencies are described in chapter Fehler! Verweisquelle konnte nicht gefunden werden. Appendix beginning at sheet ECGs. The according field names are described in chapter Import For an import the according device type must be selected. Via Import XLS-data the Excel file can be selected and the import starts. In the view Messages all steps including errors will be displayed. The messages of the import procedure can be documented via Save as file in a txt file or copy to clipboard in other files. The content will be deleted before the next action of the ETS App automatically. 12 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

13 Figure 6-1 successful import of Excel file Siemens AG DS01 13 / 28 Control Products and Systems Siemens AG

14 7 Messages Errors during import are displayed in text field Messages. Find typical error descriptions and possible steps to solve these in the following section. 7.1 Wrong device type selected If a user tries to import another template of device type than created as template, typically these errors will be displayed. Reason: The following example shows the messages for type N 141/31 if you import device type N 141/21. Solution: Ensure that device type of template for import matches together. Row 0, col 'Emergency mode', object 'DALI groups': column does not exist in sheet Row 0, col 'Dimming value emergency mode', object ' DALI groups ': column does not exist in sheet Row 0, col 'Behavior after emergency mode', object ' DALI groups': column does not exist in sheet Row 0, col 'Behavior after burn-in ', object ' DALI groups': column does not exist in sheet Row 0, col 'Operation mode', object 'ECGs': column does not exist in sheet Row 0, col 'Minimum dimming value', object 'ECGs': column does not exist in sheet Row 0, col 'Maximum dimming value', object 'ECGs': column does not exist in sheet 7.2 Data not valid with this conditions This error message will be displayed, if a value cannot be imported because of wrong conditions or dependencies to other parameters. e.g. Parameter Duration night mode in the same column in sheet Gateways in 2. row causes through Sheet Gateways, row 2, col ' Duration night mode ', Object '1.1.21': value 10 is not possible under these conditions. Because of this error during import the device was not added. In this example above the user has selected no for night mode active, but additional Duration night mode was set to 10 min. The ETS App cannot decide which parameter is correct. Solution: The user has to verify the parameters. 7.3 Data out of range This error message will be displayed, if a value is out of valid range. e.g. Parameter Delay after restart in the same column in sheet Gateways in 3. row, which is between 00:00 and max. 04:15. Sheet Gateways, row 3, column Delay after restart, Object '1.1.22': value 04:30 is out of range Because of this error during import the device was not added. Because of ETS App cannot decide, which parameter should be implemented the device will not be added to the project. Solution: The user has to verify the parameters. 7.4 Address already in use If the physical address of the device is already used, the device will be added with the following message and with the next free address in the same KNX line. 14 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

15 The desired address is occupied. The imported device was created at address Specialty of ETS5 This ETS App is developed for ETS4.2.. It can be used with ETS5 as well. The main difference is the use of the product database catalogue, which can cause occur this error message: devices from Siemens found in catalog / project. Figure 7-1 devices from Siemens found in catalog / project. device found with manufacturer Siemens, application no and application-version-id 03 in catalog / project. Figure 7-2 Missing specific device here N 141/21 If one of these messages will be displayed in ETS4.2, the products are not available in the product catalogue. Solution: Import the product database in ETS via KNX Online Catalogue or von In case of ETS5 the device must be added additional once in the project. The device can be deleted afterwards at once again. Siemens AG DS01 15 / 28 Control Products and Systems Siemens AG

16 8 Appendix In the following tables show the column names (field names) in the 1 st line of the XLSX file. If fields are left empty, the default values will be used. The field types show which fields are mandatory or optional. Type of field: Type Description M Mandatory field. An empty field causes an error message. M31 Mandatory filed only for device type N 141/31 O Optional field P Optional fields for device types N 141/21 and N 141/03. In case of N 141/31 no data must be added. The tables describe first the parameters and then the communication objects. Column name (fields) for parameters and Communication objects in line 1 Sheets 16 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

17 8.1 Column names of XLSX file Sheet Gateways Type Column - sheet Gateways Parameter in ETS Range of values Default value M Gateway Gateway phys. KNX Address e.g M Gateway name Gateway name O Description Description O DALI status failure DALI, status failure O Group status switching Group, status switching O Group status dimming value Group, status dimming value O Group status failure Group, status failure O Channel status failure Channel, status failure Send only on read request Send status changes Send status changes / bus voltage recovery Send only on read request Send status changes Send status changes / bus voltage recovery Send only on read request Send status changes Send status changes / bus voltage recovery Send only on read request Send status changes Send status changes / bus voltage recovery Send only on read request Send status changes Send status changes / bus voltage recovery O Optimize DALI communication after return of power supply Optimize DALI communication after return of power supply, Yes O ON period during direct mode ON period during direct mode [minutes, 0 = endless] O Night mode Night mode, Yes Yes O On-time night mode On-time night mode [minutes] O Delay after restart Delay after restart [mm:ss] 00:00 04:15 00:00 O At bus powered failure switch to standalone mode At bus power failure switch to standalone mode, Yes Send status changes / bus voltage recovery Siemens AG DS01 17 / 28 Control Products and Systems Siemens AG

18 Type Column - sheet Gateways Parameter in ETS Range of values Default value O Behavior after partial download Behavior after partial download ECG off, controls disabled ECG on, controls enabled Like before download Like before download O Optimized acknowledge Optimized acknowledge, Yes Yes O Channel A failure of more than DALI devices Channel A, failure of >= DALI device(s) O Channel B failure of more than DALI devices Channel B, failure of >= DALI device(s) O Transmission period after state change value Transmission period after state change value [seconds] O On period lock failure messages On period lock failure messages [mm:ss] (0 = endless) 00:00 59:59 00:00 P ECG status switching ECG, status switching Send only on read request Send status changes Send status changes / bus voltage recovery P ECG status dimming value ECG, status dimming value Send only on read request Send status changes Send status changes / bus voltage recovery P ECG status failure ECG, status failure P ECG test ECG, test P ECG Test result ECG, Test result Send only on read request Send status changes Send status changes / bus voltage recovery Send only on read request Send status changes Send only on read request Send at the end of testing Send only on read request Send at the end of testing P Extended test result Extended test result Send only on read request Send at the end of testing Send at the end of testing P Record test results Record test results Yes, P Test results status memory capacity Test results, status memory capacity Send only on read request Send status changes Send status changes / bus voltage recovery 18 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

19 Type Column - sheet Gateways Parameter in ETS Range of values Default value P Test results memory capacity left Test results, memory capacity left Send only on read request Send status changes Send status change and undershot threshold Send status changes / bus voltage recovery P Threshold for memory capacity left Threshold for memory capacity left P Duration Burn-in Duration Burn-in [h] P Delay after emergency mode OFF Delay after emergency mode OFF [mm:ss] 00:00 20:00 00:00 Type Column - sheet Gateways Communication objects in ETS O night mode GroupAddress night mode O net power failure GroupAddress net power failure O direct mode status GroupAddress direct mode status P emergency mode GroupAddress emergency mode P status memory capacity GroupAddress status memory capacity P memory capacity left GroupAddress memory capacity left O failure messages disabled GroupAddress failure messages disabled Siemens AG DS01 19 / 28 Control Products and Systems Siemens AG

20 8.1.2 Sheet DALI Lines Type Column - sheet DALI Lines Parameter in ETS Range of values Default value M Gateway Gateway phys. KNX Address e.g M DALI Line DALI Line A, B, 1, 2 O DALI channel mode DALI channel mode (change of channel mode will reset all settings of the channel.) Disabled rmal mode (bus mode) Broadcast rmal mode (bus mode) O Operating mode Operating mode rmal mode rmal- / night-mode Constant light Time switch 1-level Time switch 2-level rmal mode O Minimum dimming value Minimum dimming value 0%-100% 10% O Maximum dimming value Maximum dimming value 0%-100% 100% O Power-on mode Power-on mode Switch-on value Last dimming value Dimming value at switch off Switch-on value O Switch-on value Switch-on value 0%-100% 100% Dimming time at switching on / off O Dimming time at switching on / off from min % [hh:mm:ss] 00:00:00 15:00:00 00:00:00 Dimming time at dimming brighter/darker O Dimming Time Brighter/Darker [s] from min % [hh:mm:ss] 00:00:01 15:00:00 00:00:10 Dimming time at dimming value O Dimming Time at dimming value from min % [hh:mm:ss] 00:00:00 15:00:00 00:00:00 O Switch-on time 1 Switch-on time 1 [hh:mm:ss] 00:00:00 15:00:00 00:02:00 O Switch-on time 2 Switch-on time 2 [hh:mm:ss] 00:00:00 15:00:00 00:00:30 O Dimming Value after Switch-on time 1 Dimming value after switch-on time 1 0%-100% 5% O Behavior in case of failure KNX voltage or DALI voltage Behavior in case of failure KNX voltage or DALI voltage action Switch on value Maximum dimming value Minimum dimming value Dimming value at emergency illumination Switch off action 20 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

21 Type Column - sheet DALI Lines Parameter in ETS Range of values Default value O Behavior in case of return KNX voltage or DALI voltage Behavior in case of return KNX voltage or DALI voltage action like before bus voltage failure Switch on value Maximum dimming value Minimum dimming value Switch off Last received dimming value like before bus voltage failure O Warn before switching off Warn before switching off, Yes O Switching ON/OFF via dimming brighter/darker Switching ON/OFF via dimming brighter/darker t possible Switching on possible Switching off possible Switching off / on possible t possible O Switching On/Off via set dimming value Switching On/Off via set dimming value O 8-bit dimming value 8 bit dimming value t possible On if dimming value >= minimum dimming value Off if dimming value < minimum dimming value Switching off / on possible On if dimming value > 0% and off if dimming value = 0% Adopt immediately Adopt at ON only action Approach value t possible Adopt immediately P Behaviour in emergency mode Behaviour in emergency mode Approach value P Dimming value with emergency mode Dimming value with emergency mode 0%-100% 100% like before emergency mode Switch on value Maximum dimming value Minimum dimming value Switch off Last received dimming value P Behaviour in emergency mode OFF Behavior in Emergency mode OFF action P Behaviour after burn-in Behaviour after burn-in like before burn-in Switch off max. dimming value min. dimming value no burn-in possible like before emergency mode like before burn-in Siemens AG DS01 21 / 28 Control Products and Systems Siemens AG

22 Type Column - table DALI Lines Communication objects in ETS O switching GroupAddress channel, broadcast, switching O dimming GroupAddress channel, broadcast, dimming O dimming value GroupAddress channel, broadcast, dimming value O dimming value / time GroupAddress channel, broadcast, dimming value/time O status switching GroupAddress channel, broadcast, status switching O status dimming value GroupAddress channel, broadcast, status dimming value O status failure GroupAddress channel, broadcast, status failure O DALI device failure GroupAddress channel, DALI device failure O DALI shortcut GroupAddress channel, DALI shortcut P test result extended GroupAddress channel, extended test result P Burn-in GroupAddress channel, burn-in P Burn-in status GroupAddress channel, burn-in status O error status GroupAddress channel, Error status 22 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

23 8.1.3 Sheet DALI Groups Type Column - table DALI Groups Parameter in ETS Range of values Default value M Gateway Gateway phys. KNX Adresse e.g M DALI Line DALI Line A, B, 1, 2 M31 DALI Group DALI Group (max. 25 characters) (max. 25 characters) O Operating mode Operating mode rmal mode rmal- / night-mode Constant light Time switch 1-level Time switch 2-level rmal mode O Minimum dimming value Minimum dimming value 0%-100% 10% O Maximum dimming value Maximum dimming value 0%-100% 100% O Power-on mode Power-on mode Switch-on value Last dimming value Dimming value at switch off Switch-on value O Switch-on value Switch-on value 0%-100% Dimming time at switching on / off O Dimming time at switching on / off from min % [hh:mm:ss] 00:00:00 15:00:00 00:00:00 Dimming time at dimming brighter/darker O Dimming Time Brighter/Darker [s] from min % [hh:mm:ss] 12:00:01 AM 15:00:00 00:00:10 Dimming time at dimming value O Dimming Time at dimming value from min % [hh:mm:ss] 00:00:00 15:00:00 00:00:00 O Switch-on time 1 Switch-on time 1 [hh:mm:ss] 00:00:00 15:00:00 00:02:00 O Switch-on time 2 Switch-on time 2 [hh:mm:ss] 00:00:00 15:00:00 00:00:30 O Dimming Value after Switch-on time 1 Dimming value after switch-on time 1 0%-100% 5% O Behavior in case of failure KNX voltage or DALI voltage Behavior in case of failure KNX voltage or DALI voltage action Switch on value Maximum dimming value Minimum dimming value Dimming value at emergency illumination Switch off action Siemens AG DS01 23 / 28 Control Products and Systems Siemens AG

24 Type Column - table DALI Groups Parameter in ETS Range of values Default value O Behavior in case of return KNX voltage or DALI voltage Behavior in case of return KNX voltage or DALI voltage action like before bus voltage failure Switch on value Maximum dimming value Minimum dimming value Switch off Last received dimming value like before bus voltage failure O Warn before switching off Warn before switching off Yes, O Switching ON/OFF via dimming brighter/darker Switching ON/OFF via dimming brighter/darker t possible Switching on possible Switching off possible Switching off / on possible t possible O Switching On/Off via set dimming value Switching On/Off via set dimming value O 8-bit dimming value 8 bit dimming value t possible On if dimming value >= minimum dimming value Off if dimming value < minimum dimming value Switching off / on possible On if dimming value > 0% and off if dimming value = 0% Adopt immediately Adopt at ON only action Approach value t possible Adopt immediately P Behaviour in emergency mode Behaviour in emergency mode Approach value P Dimming value with emergency mode Dimming value with emergency mode 0%-100% 100% action like before emergency mode Switch on value Maximum dimming value Minimum dimming value Switch off P Behaviour in emergency mode OFF Behavior in Emergency mode OFF Last received dimming value P Behaviour after burn-in Behaviour after burn-in like before burn-in Switch off max. dimming value min. dimming value no burn-in possible like before emergency mode like before burn-in 24 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

25 Type Column - sheet DALI Groups Communication objects in ETS O switching GroupAddress Channel, Group, switching O dimming GroupAddress Channel, Group, dimming O dimming value GroupAddress Channel, Group, dimming value O dimming value / time GroupAddress Channel, Group, dimming value/time O status switching GroupAddress Channel, Group, Switch status O status dimming value GroupAddress Channel, Group, dimming value status O status failure GroupAddress Channel, Group, status failure Sheet ECGs See chapter 8.2 CSV file and sheet ECGs field names Sheet Group addresses Type Column - sheet Group addresses Parameter in ETS Range of values Default value O Group Address Group Address 2 or 3 level type e.g. 1/2/3 or 1/24 O Group Address Name Group Address Name O Group Address Description Group Address Description O Group Address Comment Group Address Comment Siemens AG DS01 25 / 28 Control Products and Systems Siemens AG

26 8.2 CSV file and sheet ECGs field names Type Column - sheet ECGs Parameter in ETS Range of values Default value M Gateway Gateway phys. KNX Address e.g M ECG Name Name M DALI Line DALI Line A, B, 1, 2 M DALI Group DALI Group O 0 - Fluorescent lamps Device type x P 1 - Self-contained emergency lighting Device type x O 2 - Discharge lamps Device type x O 3 - Low voltage halogen lamps Device type x O 4 - Incandescent lamps (dimmer) Device type x O 5-10V converter Device type x O 6 - LED modules Device type x O 7 - Switching function Device type x P CIN Device identification number (CIN) (16 digits = 8x 2-digit numbers) FF:FF:FF:FF:FF:FF:FF:FF P BrightnessControl 0 - Fluorescent Lamps additional functions With brightness control additional functions P Emergency light Emergency Light Single battery emergency luminaire with 1 DALI device Single battery emergency luminaire with 2 DALI device Central battery supplied P Emergency light Emergency Light Converter dimming value emergency operation Converter dimming value emergency operation P 0%-100% 100% P Converter prolog time Converter prolog time [min] P Partial duration test interval Partial duration test interval (weeks) P Duration test interval Duration test interval (weeks) P Function test interval Function test interval (days) P Duration partial duration test Duration partial duration test (min) P Operating mode Operating mode rmal mode rmal- / night-mode Constant light Time switch 1-level Time switch 2-level rmal mode P Minimum dimming value Minimum dimming value 0%-100% 10% Single battery emergency luminaire with 2 DALI device 26 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

27 Type Column - sheet ECGs Parameter in ETS Range of values Default value P Maximum dimming value Maximum dimming value 0%-100% 100% P Power-on mode Power-on mode Switch-on value Last dimming value Dimming value at switch off Switch-on value P Switch-on value Switch-on value 0%-100% P Behaviour in emergency mode Behaviour in emergency mode action Approach value Approach value P Dimming value with emergency mode Dimming value with emergency mode 0%-100% 100% P Behaviour in emergency mode OFF Behavior in Emergency mode OFF like before emergency mode Switch on value Maximum dimming value Minimum dimming value Switch off Last received dimming value action like before emergency mode P Behaviour after burn-in Behaviour after burn-in like before burn-in Switch off max. dimming value min. dimming value no burn-in possible like before burn-in Dimming time at switching on / off P Dimming time at switching on / off from min % [hh:mm:ss] 00:00:00 15:00:00 00:00:00 Dimming time at dimming brighter/darker P Dimming Time Brighter/Darker [s] from min % [hh:mm:ss] 12:00:01 AM 15:00:00 00:00:10 Dimming time at dimming value P Dimming Time at dimming value from min % [hh:mm:ss] 00:00:00 15:00:00 00:00:00 P Switch-on time 1 Switch-on time 1 [hh:mm:ss] 00:00:00 15:00:00 00:02:00 P Switch-on time 2 Switch-on time 2 [hh:mm:ss] 00:00:00 15:00:00 00:00:30 P Dimming Value after Switch-on time 1 Dimming value after switch-on time 1 0%-100% 5% P Behavior in case of failure KNX voltage or DALI voltage Behavior in case of failure KNX voltage or DALI voltage action Switch on value Maximum dimming value Minimum dimming value Dimming value at emergency illumination Switch off action Siemens AG DS01 27 / 28 Control Products and Systems Siemens AG

28 Type Column - sheet ECGs Parameter in ETS Range of values Default value P Behavior in case of return KNX voltage or DALI voltage Behavior in case of return KNX voltage or DALI voltage action like before bus voltage failure Switch on value Maximum dimming value Minimum dimming value Switch off Last received dimming value like before bus voltage failure P Warn before switching off Warn before switching off Yes, P Switching ON/OFF via dimming brighter/darker Switching ON/OFF via dimming brighter/darker t possible Switching on possible Switching off possible Switching off / on possible t possible P Switching On/Off via set dimming value Switching On/Off via set dimming value P 8-bit dimming value 8 bit dimming value t possible On if dimming value >= minimum dimming value Off if dimming value < minimum dimming value Switching off / on possible On if dimming value > 0% and off if dimming value = 0% Adopt immediately Adopt at ON only t possible Adopt immediately Type Column - table EVGs Communication objects in ETS P ECG test result GroupAddress Channel, ECG, test result P ECG test GroupAddress Channel, ECG, test P switching GroupAddress Channel, ECG, switching P dimming GroupAddress Channel, ECG, dimming P dimming value GroupAddress Channel, ECG, dimming value P dimming value / time GroupAddress Channel, ECG, dimming value/time P status switching GroupAddress Channel, ECG, Switch status P status dimming value GroupAddress Channel, ECG, dimming value status P status failure GroupAddress Channel, ECG, status failure 28 / 28 DS01 Siemens AG Siemens AG 2016 Control Products and Systems

Contents. GAMMA instabus Application program - Descriptions. June B0 KNX / DALI Gateway Twin N 141/

Contents. GAMMA instabus Application program - Descriptions. June B0 KNX / DALI Gateway Twin N 141/ Contents 1. Product description...2 1.1 DALI fundamentals...2 1.2 Gateway fundamentals...2 2. Functional overview...2 2.1 Modes... 3 2.1.1 Normal mode... 3 2.1.2 Standalone mode... 3 2.1.3 Direct mode...

More information

Contents. GAMMA instabus Application program description. August 2017

Contents. GAMMA instabus Application program description. August 2017 Contents 1. Product description 4 1.1 DALI fundamentals... 4 1.2 Gateway fundamentals... 4 2. Functional overview of both devices 5 2.1 Modes... 5 2.2 Replace defective DALI-ECGs... 7 2.3 Failure messages

More information

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016

Use of the application program. Contents overview. Gamma instabus Application program description. November 2016 Use of the application program Product family: Product type: Manufacturer: Application: Name: Description: Order no: Application: Name: Description: Order no: Lighting Dimmer Siemens Switch-/Dimming Actuator

More information

Use of the application program

Use of the application program Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Output Controller Siemens UP 255/11 brightness controller or AP 255/12 brightness controller 5WG1 255-4AB11 or

More information

DALI Link User Manual

DALI Link User Manual 1.Overview Digital Addressable Lighting Interface (DALI) is a communication protocol for lighting control in buildings. The interface was first described in the IEC60929 standard for fluorescent lamp ballast,

More information

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit

Use of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit Use of the application program Product family: Product type: Manufacturer: Displays Display and operating units Siemens AG Name Room control unit UP 227 DELTA i-system Order no.: Table of Contents 5WG1

More information

Use of the application program

Use of the application program Use of the application program Product family: Product type: Manufacturer: Display Display units Siemens AG Name: Contouch Room Controller UP 204 Order no.: 5WG1 204-2AB11, titanium white, 5WG1 204-2AB21,

More information

Table of contents. Use of the application program. GAMMA instabus Application program description. July B CO IP Gateway KNX-BACnet

Table of contents. Use of the application program. GAMMA instabus Application program description. July B CO IP Gateway KNX-BACnet Table of contents Use of the application program... 1 1.Functional description... 2 Behavior at bus voltage failure / recovery... 4 Factory default state... 4 Behavior on unloading the application program...

More information

Use of the application program

Use of the application program Use of the application program Product family: Product type: Manufacturer: Display Display units Siemens AG Name: Contouch Room Controller UP 204 Order no.: 5WG1 204-2AB11, titanium white, 5WG1 204-2AB21,

More information

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information Gamma instabus Technical Product Information RL 513D23 Switching actuator (relay), 3 x 6A 5WG1 513-4DB23 Switching actuator for independent switching of three lighting luminaire groups or other loads one

More information

PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX. Product Handbook

PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX. Product Handbook PRESENCE DETECTOR, CONSTANT LIGHT CONTROLLER PD00D01KNX Product Handbook Product: PD00D01KNX Description: PRESENCE DETECTOR, CONSTANT CONTROLLER Document Version: 1.3 Date: 03/10/2017 Tribunale di Mila

More information

KNX devices can be updated using the Firmware Download Tool. The download takes place over the KNX bus.

KNX devices can be updated using the Firmware Download Tool. The download takes place over the KNX bus. KNX devices can be updated using the. The download takes place over the KNX bus. Υ NOTE WHILE THE UPDATE IS DOWNLOADING TO KNX DEVICES, THE KNX DEVICE IS NOT FUNCTIONAL. THIS IS WHY IT IS ESSENTIAL, BEFORE

More information

PRODUCT MANUAL LUZEN PLUS. Universal Dimmer ZN1DI-P400. Program version: 3.0 Manual edition: a

PRODUCT MANUAL LUZEN PLUS. Universal Dimmer ZN1DI-P400. Program version: 3.0 Manual edition: a PRODUCT MANUAL LUZEN PLUS Universal Dimmer ZN1DI-P400 Program version: 3.0 Manual edition: a INDEX Document updates... 3 1. Introduction... 4 1.1. LUZEN PLUS... 4 1.2. Types of load... 5 1.3. Installation...

More information

DALI Professional Frequently asked questions Light is OSRAM

DALI Professional Frequently asked questions Light is OSRAM www.osram.com DALI Professional Frequently asked questions Light is OSRAM DALI PROFESSIONAL Frequently Asked Questions What is the max. cable length in OSRAM DALI PROFESSIONAL system? Is it 300 m in total

More information

HiPath Description. We are now Unify.

HiPath Description. We are now Unify. HiPath Description We are now Unify. This document references our previous company name; all othercontent is still valid and correct. For further information, please visit unify.com HiPath License Management

More information

Technical Manual. KNX/DALI ACTUATOR 1x8 channels Art /70100

Technical Manual. KNX/DALI ACTUATOR 1x8 channels Art /70100 KNX/DALI ACTUATOR 1x8 channels Art. 1630.04140/70100 DATEC ELECTRONIC AG Hochbergerstrasse 60C 4057 Basel Tel. +41 61 633 22 25, Fax. +41 61 633 22 27 www.datec.ch, support@datec.ch Because of continuous

More information

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX 307031 VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX 8269210 8269211 GB Installation and operating instructions Room thermostat D GB F I E NL VARIA 826 S KNX Contents Basic safety instructions 3 Display

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

GAMMA instabus Application Program Description. July CO Colour Touch-Panel

GAMMA instabus Application Program Description. July CO Colour Touch-Panel Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Name: Order no.: Display Display units Siemens UP 588/12 Colour Touch Panel UP 588/13 Colour Touch Panel (AC

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

KNX 2-channel Dimmer module EK-GA1-TP

KNX 2-channel Dimmer module EK-GA1-TP KNX 2-channel Dimmer module EK-GA1-TP Contents 1 Scope of the document... 4 2 Product description... 5 3 Switching, display and connection elements... 6 4 Configuration... 7 5 Commissioning... 7 6 Function

More information

Communication objects. Use of the application program. Note. Functional description. Parameters General

Communication objects. Use of the application program. Note. Functional description. Parameters General Use of the application program Product family: Product type: Manufacturer: Input Binary input, 4-fold Siemens Name: Push button interface UP 220/03 Order no.: 5WG1 220-2AB03 Name: Push button interface

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

KNX DALI-Gateway Basic REG-K/1/16/64

KNX DALI-Gateway Basic REG-K/1/16/64 Using the application program Product family: Product type: Manufacturer: Name: Order no.: 1.3 Interfaces/Gateways 1.3.13 DALI-Gateway Schneider Electric Industries SAS KNX DALI-Gateway Basic REG-K/1/16/64

More information

DALI Touchpanel. Manual. Control Device. Multifunctional DALI control device with flexible layout. Art. Nr Art.Nr.

DALI Touchpanel. Manual. Control Device. Multifunctional DALI control device with flexible layout. Art. Nr Art.Nr. DALI Touchpanel Manual Control Device Multifunctional DALI control device with flexible layout Art. Nr. 24035465 Art.Nr. 24035465-AL DALI Touchpanel DALI Touchpanel Control Module Content 1. Function...

More information

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD KNX Product documentation Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD Issue: 19.12.2012 Page 1 of 153 KNX Product documentation Contents 1 Product

More information

application software

application software application software application software RF input product Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices 8565 52 xx 8565 62

More information

Description of SMS notification

Description of SMS notification The application has 4 steps: Step 1 - entering recipients Description of SMS notification Sending SMS Several methods of adding a list of recipients and SMS content to the message are available: file upload;

More information

OT EASY 60 II. LED control unit Operating instructions

OT EASY 60 II. LED control unit Operating instructions II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

KNX DALI Gateway Plus - User Manual

KNX DALI Gateway Plus - User Manual KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64

More information

Lighting control for commercial buildings

Lighting control for commercial buildings [ INTELLIGENT SOLUTIONS ] Products and systems Lighting control for commercial buildings For management of different functions in a simultaneous and integrated way, via a BUS line Cost saving thanks to

More information

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX

Switching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1

More information

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-020: Answers for infrastructure and cities. SIPROTEC 5 - Application: Content 1 Application: 3 1.1 Summary 3 1.2 General 3 1.3 Download PICS

More information

Product and function description

Product and function description Product and function description Fig. 1 This document provides information on the full range of functions for the 983403 (Firmware V03). The range of functions of 141/03 983703 is limited to channel A.

More information

Product documentation

Product documentation Product documentation DALI gateway ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de Service Center Kupferstr.

More information

Use of the application program

Use of the application program Use of the application program Product family: Product type: Manufacturer: with red LED cover with white LED cover Functional description Push button Push button, 4-fold Siemens Push button UP 212 titanium

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

Tebis application software

Tebis application software 5 Tebis application software SXB322AU V 1.x 2 inputs / 2-output module LED SXB344AU V 1.x 4 inputs / 4-output module LED Product reference Product designation TXB322AU TXB344AU Embedded module: 2 inputs

More information

Connections, displays and operating elements

Connections, displays and operating elements KNX DALI gateway REG-K/1/16(64)/64MTN680191 Merten2005V6801-561-0007/08 GB KNX DALI gateway REG-K/1/16(64)/64 Operating instructions MTN680191 For your safety Connections, displays and operating elements

More information

Technical Manual. DALI GATEWAY Art A

Technical Manual. DALI GATEWAY Art A DALI GATEWAY Art. 119914 14783 003A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850 www.tacdubai.com,

More information

Application description

Application description Manufacturer Berker Motion detector Application description KNX motion detector module comfort 1.10m KNX motion detector module comfort 2.20m ETS KNX motion detector module comfort 1.10m ETS KNX motion

More information

Technical Manual MDT DaliControl IP Gateway w/ Webinterface

Technical Manual MDT DaliControl IP Gateway w/ Webinterface 05/2013 Technical Manual MDT DaliControl IP Gateway w/ Webinterface SCN-DALI64.02 1 Content 1 Content... 2 2 Overview... 5 2.1 Operation Instructions... 5 2.2 Usage & Handling... 6 2.3 Installation DaliControl

More information

GAMMA instabus Application Program Description. November CO Touch-Panel

GAMMA instabus Application Program Description. November CO Touch-Panel Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Name: Order no.: Display Display units Siemens UP 588/2 Colour Touch Panel (AC 230 V) 5WG 588-2AB2 UP 588/22

More information

Tebis application software

Tebis application software Tebis application software 6-fold switch actuator 16A 230V current monitoring Electrical/Mechanical characteristics: See product user manual A faire Product reference Product designation Application software

More information

Translation of Original Installation Guide ESS 3.0 / ESS 7.0 Firmware

Translation of Original Installation Guide ESS 3.0 / ESS 7.0 Firmware Translation of Original Installation Guide ESS 3.0 / ESS 7.0 Firmware Adresses, Identification and Notes Impressum Product Identification Service Document Identifikation Copyright BMZ Batterien-Montage-Zentrum

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

IntesisBox MAPS. Configuration & monitoring software of IntesisBox Modbus series. User's manual Issue Date: 01/18 r1.1 eng

IntesisBox MAPS. Configuration & monitoring software of IntesisBox Modbus series. User's manual Issue Date: 01/18 r1.1 eng IntesisBox MAPS Configuration & monitoring software of IntesisBox Modbus series User's manual Issue Date: 01/18 r1.1 eng Intesis Software S.L.U. 2018 All Rights Reserved. Information in this document is

More information

EAE KNX Room Control Unit Product Manual RCUXXYY

EAE KNX Room Control Unit Product Manual RCUXXYY EAE KNX Room Control Unit Product Manual RCUXXYY RCU2018 RCU2016 RCU1212 RCU0808 RCU2000 RCU2000 RCU1200 RCU0800 Note: RCUXXYY where XX denotes the number of outputs and YY number of inputs. Index 1 General...

More information

EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO

EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO EDIFICIOS INTELIGENTES Y MULTIMEDIA: DOMOTICA Y CABLEADO ESTRUCTURADO Hojas de Aplicaciones para los módulos domóticos de Siemens de las Prácticas 5 y 6 Producto Número Pedido Programa Aplicación Base

More information

Application program description

Application program description Content 1. Using the application program... 4 2. General product information... 4 2.1. DALI Bus system properties... 4 2.2. product features... 4 3. General properties of the ETS application program: DALI

More information

Wi-Fi Lighting Controls ELECTRONIC GMBH

Wi-Fi Lighting Controls ELECTRONIC GMBH Wi-Fi Lighting Controls ELECTRONIC GMBH Contents The WiFi AQStation System Characteristics of the Wi-Fi AQStation System The AQStation Universal, Technical Data, wiring diagram AQStation Universal in combination

More information

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/

K-BUS R. Dimming Actuators. User manual-ver. 4 KA/D KA/D KA/D KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/ Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Dimming Actuators User manual-ver. 4 KA/D 0103.1 KA/D 0203.1 KA/D 0403.1 KA/D 04.T1.1 ADTV-04/16.1 KA/D 04.L1.1 ADLD-04/03.1...... KNX/EIB Intelligent

More information

USER MANUAL 1 OZONE TOOLSET PC SOFTWARE SW VERSION V Ozone ToolSet PC Software User Manual

USER MANUAL 1 OZONE TOOLSET PC SOFTWARE SW VERSION V Ozone ToolSet PC Software User Manual Ozone ToolSet PC Software User Manual www.efore.com Page 1 UM1_Ozone ToolSet_Rev06, June 2016 Table of Contents 1. Introduction... 3 2. Minimum PC Requirements and License Agreement... 4 3. Software Installation

More information

Operation and installation manual KNX IP Multi IO 580 (48I/O) Application. 2. Factory default settings. 1. Installation and connection ❹ ❼ ❻ ❷

Operation and installation manual KNX IP Multi IO 580 (48I/O) Application. 2. Factory default settings. 1. Installation and connection ❹ ❼ ❻ ❷ EN ❶ Operation and installation manual KNX IP Multi IO 580 (48I/O) (Art. # 5238) KNX IP Multi IO with 48 configurable In- and Outputs ❸ ❹ ❼ ❺ ❽ ❻ ❷ ❶ ❶ ❶ Inputs and Outputs 1-48 ❷ LAN Connector ❸ OLED

More information

EXCEL IMPORT user guide

EXCEL IMPORT user guide 18.2 user guide No Magic, Inc. 2015 All material contained herein is considered proprietary information owned by No Magic, Inc. and is not to be shared, copied, or reproduced by any means. All information

More information

RSR-DALI User Manual. What is the RSR-DALI?

RSR-DALI User Manual. What is the RSR-DALI? RSR-DALI User Manual This manual covers all features of the RSR-DALI, for a simple step by step guide to programming DALI in Rasoft Pro see DALI programming quick guide. What is the RSR-DALI? The RSR-DALI

More information

BAC/S1.5.1 Building Automation Controller Function Description

BAC/S1.5.1 Building Automation Controller Function Description BAC/S1.5.1 Building Automation Controller Function Description GPG BUILDING AUTOMATION 9.11 Doc.-Type: Function Description Doc.-Nr. 9AKK107046A7725 Revision: B Department: BA Engineering Author: Engineering

More information

SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION

SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION SWISS GARDE 360 HOKUSPOKUS KNX/KLR APPLICATION DESCRIPTION MODEL TYPE NO. SG HOKUSPOKUS KNX/KLR 25010 Program version 2.7 2012 M. Züblin AG Neue Winterthurerstrasse 30, 8304 Wallisellen, Switzerland The

More information

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual

ABB i-bus KNX DALI Gateway Emergency Lighting DGN/S Product Manual DALI Gateway Emergency Lighting DGN/S 1.16.1 Product Manual Contents Contents Page 1 General... 3 1.1 Product and functional overview...4 1.2 DALI general...6 1.3 ABB i-bus DALI-Gateway in comparison...7

More information

KNX function and configuration

KNX function and configuration 2 KNX function and configuration Introduction A presence detector monitors the detection zone for occupancy, and causes one or more actions to be executed when a person enters the detection area. In their

More information

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001 SK 0012 B 98 The control unit is a DIN rail mounted device for insertion in the distribution board. It is used to control digitally dimmable electronic ballast devices or transformers via the EIB. In a

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

High-performance switching actuators

High-performance switching actuators High-performance switching actuators Wide-ranging applications efficient installation and set-up operation for many years The worldwide standard for home and building control siemens.com/gamma Switching

More information

Use of the application program. Functional description. GAMMA instabus Application program description. March S1 rocker (BCU2)

Use of the application program. Functional description. GAMMA instabus Application program description. March S1 rocker (BCU2) Use of the application program Product family: Product type: Manufacturer: Push button Push button, 1-fold Siemens Name: Pushbutton UP 241, single, neutral DELTA profil Order-no.: 5WG1 241-2AB_1 Name:

More information

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-010: Answers for infrastructure and cities. SIPROTEC 5 - Application: SIP5-APN-010 SIPROTEC 5 Application Content 1 Application 3 1.1 Summary

More information

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-014: Answers for infrastructure and cities. SIPROTEC 5 - Application: SIP5-APN-014 Mixed configurations of SIPROTEC 4 and SIPROTEC 5 Content

More information

Sirius Lighting Design User Manual

Sirius Lighting Design User Manual Sirius Lighting Design User Manual Updated 21 Mar, 2016 Page 1 / 32 Table of Contents 1 Introduction... 3 2 System requirements... 4 3 Interface board... 5 4 GUI for Sirius Lighting Design... 6 4.1 Main

More information

SNMP Web Management. User s Manual

SNMP Web Management. User s Manual SNMP Web Management User s Manual Suitable Product: SNMP Web Card SNMP Web Box Management Software for Uninterruptible Power Supply Systems Table of Contents 1. Overview... 1 1.1 Introduction... 1 1.2

More information

- Recent developments in the IEC standard and impact on lighting technology

- Recent developments in the IEC standard and impact on lighting technology - Recent developments in the IEC 62386 standard and impact on lighting technology Dr. Scott Wade, Technical & Certification Manager Presented at Light+Building 2018 Wednesday 21st March at 16:00 Hall 8.0,

More information

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual

ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual ABB i-bus KNX Application Unit Time ABZ/S 2.1 Product Manual ABZ/S, Application Unit Time Contents Page 1 General 6 1.1 Product and functional description...7 2 Device technology 8 2.1 Technical data...8

More information

Application description for the KNX Roombox. (Art. no. ORBK8L0S4HW/ORBK8D0S4HW/ORBK4L4S4HW/ORBK4D4S4HW)

Application description for the KNX Roombox. (Art. no. ORBK8L0S4HW/ORBK8D0S4HW/ORBK4L4S4HW/ORBK4D4S4HW) Application description for the KNX Roombox (Art. no. ORBK8L0S4HW/ORBK8D0S4HW/ORBK4L4S4HW/ORBK4D4S4HW) Introduction to the ORB plug-in... 1 Zone Global... 9 Zone Energy metering... 11 Push-button interface...

More information

DALI Wizard Analysis and commissioning tool for DALI installations ECG configuration tool Light is OSRAM

DALI Wizard Analysis and commissioning tool for DALI installations ECG configuration tool Light is OSRAM www.osram.com DALI Wizard Analysis and commissioning tool for DALI installations ECG configuration tool Light is OSRAM Contents DALI Wizard... 1 Analysis and commissioning tool for DALI installations...

More information

Using the application program. Functional description. GAMMA instabus Application Program Description. October Event Module 800A06

Using the application program. Functional description. GAMMA instabus Application Program Description. October Event Module 800A06 Using the application program Product range: Product type: Manufacturer: Controllers Controllers Siemens Name: Event Module N 341 Order No.: 5WG1 341-1AB01 Functional description With the help of a special

More information

DALI Gateway KNX plus. Manual. Application description for the DALI-Gateway KNX plus

DALI Gateway KNX plus. Manual. Application description for the DALI-Gateway KNX plus Manual Application description for the DALI-Gateway KNX plus 01/2017 Theben HTS AG Page 1 of 66 Content 1. Use of the application programme...4 2. General product information...4 2.1 DALI bus system properties...

More information

Sirius Lighting Design ENG User Manual

Sirius Lighting Design ENG User Manual Sirius Lighting Design ENG User Manual Updated 17 July, 2017 Copyrightc 2017 LG Innotek Co., Ltd. Table of Contents 1 Introduction... 1-- 4-2 System requirements... 2-- 5-3 Interface devices... 3-- 6-3.1

More information

EAE KNX Switch Actuator

EAE KNX Switch Actuator EAE KNX Switch Actuator Order Number: 48002 Content 1 General... 2 2 Device Technology... 3 2.1 Connection Diagram... 3 2.2 Technical Data... 4 3 Communication Object Table... 5 4 Parameters... 6 4.1 Main

More information

wdali MC Datenblatt Wireless DALI Multi Control Module wireless- control module for DALI circuits and four freely programmable switching inputs

wdali MC Datenblatt Wireless DALI Multi Control Module wireless- control module for DALI circuits and four freely programmable switching inputs wdali MC Datenblatt Wireless DALI Multi Control Module wireless- control module for DALI circuits and four freely programmable switching inputs Art. Nr. 89453848 subject to change, Information provided

More information

User Manual PDUTracker

User Manual PDUTracker User Manual PDUTracker Management Software for PDU Table of Contents 1. Overview... 1 1.1. Introduction... 1 1.2. Features... 1 2. Install and Uninstall... 1 2.1. System Requirement... 1 2.2. Software

More information

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB

Product Manual V ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1. Intelligent Installation Systems ABB Product Manual V1-0 31.07.2006 ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1 Intelligent Installation Systems ABB This manual describes the function of the 1-fold DALI-Gateway with its application programs

More information

Brief description SV - Server. Smart Visu Server

Brief description SV - Server. Smart Visu Server Brief description SV - Server Smart Visu Server Brief description SV - Server The concept of the Visu-Server allows to generate an attractive visualisation of a KNX project with a few clicks only. An IP-Gateway

More information

Installation and Operating Instructions. PC Software CGLine+ Web-Controller

Installation and Operating Instructions. PC Software CGLine+ Web-Controller PC Software CGLine+ Web-Controller Installation and Operating Instructions PC Software CGLine+ Web-Controller Target group: Installer, end user PC Software CGLine+ Web-Controller Content INTRODUCTION /

More information

Gateway configuration manual DALI KNX EK-BP1-TP

Gateway configuration manual DALI KNX EK-BP1-TP DALI KNX EK-BP1-TP Indice Scope of the document... 3 1 Product description... 3 1.1 Main functions... 4 1.2 Technical data... 4 1.3 Supply... 5 1.4 System requirements for configuration software... 5 1.5

More information

Application program usage. Functional description. instabus EIB Application Program Description. December IP-Router

Application program usage. Functional description. instabus EIB Application Program Description. December IP-Router Application program usage Product family: Product type: Manufacturer: Name: Order-No.: System devices IP- Siemens Functional description IP N146 5WG1 146-1AB01 The IP N146 is a DIN rail mounted device.

More information

Colour Touch Panel 3.5

Colour Touch Panel 3.5 Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Colour Touch Panel 3.5 User manual-ver. 1.2 CHTF-35/01.1 CHTF-35/01.2.21 CHTF-35/01.2.22 CHTF-35/01.2.24 KNX/EIB Intelligent Installation Systems

More information

DALI Cockpit. Startup Guide V5. DALI Configuration Tool. Traffic Monitoring. 2017/12/15, Lunatone Industrielle Elektronik GmbH DALI Cockpit

DALI Cockpit. Startup Guide V5. DALI Configuration Tool. Traffic Monitoring. 2017/12/15, Lunatone Industrielle Elektronik GmbH DALI Cockpit DALI Cockpit Startup Guide V5 DALI Configuration Tool Commissioning of DALIcomponents and DALI-line Traffic Monitoring 2017/12/15, Lunatone Industrielle Elektronik GmbH DALI Cockpit 2 DALI Cockpit Configuration

More information

Dimmers - Clipsal by Schneider Electric

Dimmers - Clipsal by Schneider Electric 13/12/2017 Dimmers - Clipsal by Schneider Electric Dimmers Intelligent and comprehensive dimming solutions for a wide variety of control requirements. The ranges available share an innovative modular design

More information

ThermoSecure medical equipment GmbH

ThermoSecure medical equipment GmbH ThermoSecure medical equipment GmbH Thermosecure GmbH. Richmodstr 6 D-50667 Cologne Germany Tel:+ 49(0)2203 103960 Fax:+ 49(0)2203 104385 E-mail: info@thermosecure.de Manual for active thermosystems 1.1.1

More information

LUXORliving System manual Version 1

LUXORliving System manual Version 1 LUXORliving System manual Version 1 2018-04-18 Contents 1 General 3 2 System 4 3 Installation 5 4 Start-up 7 4.1 Establish a connection 7 4.2 Configuration with LUXORplug 10 4.3 Programming with LUXORplug

More information

Operation and installation manual KNX IO 511 (1O2I) Application. 1. Installation and Connection

Operation and installation manual KNX IO 511 (1O2I) Application. 1. Installation and Connection EN Operation and installation manual KNX IO 511 (1O2I) (Art. # 5232) Switching actuator with 1 output and 2 binary inputs A. KNX Programming mode The KNX programming mode is activated/deactivated either

More information

Use of the application program

Use of the application program Use of the application program Product family: Product type: Manufacturer: Output Binary Siemens Name: Switching Actuator N 53/ Order no.: 5WG 53-AB Name: Switching Actuator N 52/ Order no.: 5WG 52-AB

More information

DALI x/e-touchpanel 02. Product manual

DALI x/e-touchpanel 02. Product manual DALI x/e-touchpanel 02 Product manual Table of Contents Table of contents 1 Validity........................................................................ 4 1.1 Copyright.............................................................................

More information

DALI Commissioning Guide (Using a NPU) Contents

DALI Commissioning Guide (Using a NPU) Contents Contents 1 The edin DALI commissioning philosophy... 2 2 Requirements... 2 3 Notes... 2 4 Pre-commissioning procedure... 3 5 Creating an edin operational configuration... 5 6 Commissioning procedure...

More information

Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX

Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX Operating and Installation Instructions GePro Pushbutton KNX4 Frontlight- / Backlight 1 -KNX Email: info@knx-taster.de Internet: www.knx-taster.de Order code: Basic element KNX4 Order code: Plaster compensation

More information

DELTA profil wall switch, single UP 241/2 5WG AB_2

DELTA profil wall switch, single UP 241/2 5WG AB_2 UP 241/2 5WG1 241-2AB_2 UP 241/3,with status LED 5WG1 241-2AB_3 UP 243/2 5WG1 243-2AB_2 UP 243/3,with status LED 5WG1 243-2AB_3 UP 245/2 5WG1 245-2AB_2 UP 245/3,with status LED 5WG1 245-2AB_3 UP 245/4,with

More information

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012 Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation

More information

OPTRIS PlugIn October

OPTRIS PlugIn October OPTRIS PlugIn October 2015 12.10.2015 Information Tabel of Contents 1 Information... 3 1.1 About this manual... 3 1.1.1 Version... 3 1.1.2 Support for this PlugIn... 3 2 System Overview... 4 2.1 Introduction...

More information

Applications & Tools. SINAMICS G/S: Commissioningsupport scripts for SINAMICS drives. SINAMICS commissioning auxiliary scripts

Applications & Tools. SINAMICS G/S: Commissioningsupport scripts for SINAMICS drives. SINAMICS commissioning auxiliary scripts SINAMICS G/S: Commissioningsupport scripts for SINAMICS drives Application description July 2013 Applications & Tools Answers for industry. Siemens Industry Online Support This article originates from

More information

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply Emergency CATALOGUE Vol. 01 Lighting Decentralised and centralised supply Light is safety Light must be safe! Interior luminaire, exterior luminaire and emergency luminaire are all important to ensure

More information