MedFasee Project. Development and Applications. Department of Electrical Engineering Federal University of Santa Catarina (UFSC)
|
|
- Jayson Lamb
- 5 years ago
- Views:
Transcription
1 MedFasee Project Development and Applications Department of Electrical Engineering Federal University of Santa Catarina (UFSC) 1
2 The Federal University of Santa Catarina MedFasee Project: First Prototype (2003) The main goals were: Development of a Synchronized Phasor Measurement System prototype Applications for power system monitoring and analysis Project sponsored by: Brazilian Government (Finep/CT-Energ) Reason Tecnologia S.A. ( First Prototype 3 PMUs installed in Southern Brazil universities Three-phase low voltage Data transmission using Internet The PDC is located in the Federal University of Santa Catarina 2
3 MedFasee Project Current configuration of the National Synchronized Phasor Measurement System (SPMS MedFasee BT) PMUs are installed in 23 universities, covering the 5 geographical regions Virtual Private Network over Internet for communication between PMU and PDC (LabPlan/UFSC) PDC PMU 3
4 Main MedFasee Projects in partnership with industry First Prototype Eletrosul Project CTEEP Project (1) ONS Project CTEEP Project (2) UFSC UFSC UFSC UFSC UFSC Brazilian Government (Finep/CT-Energ) Reason Tecnologia Prototype of low voltage WAMS ELETROSUL Transmission Company R&D ANEEL Project WAMS prototype for the 500kV transmission system CTEEP Transmission Company R&D ANEEL Project WAMS prototype for the 440kV transmission system Official partnership between UFSC and the Brazilian ISO (ONS) Disturbance Analysis CTEEP Transmission Company R&D ANEEL Project Pilot system for automatic evaluation of dynamic security 4
5 MedFasee ELETROSUL Project ( ) Sponsor ELETROSUL Transmission Company Objective Development of a SPMS prototype for the ELETROSUL transmission system Developments: Prototype with 4 PMUs and 1 PDC Development of a new PDC Evaluation of the prototype performance Application for system analysis 5
6 MedFasee CTEEP Project Partner: CTEEP Transmission Company / UFSC / HPPA Project 1 ( ) Objective To implement a WAMS prototype for the 440kV transmission system of the CTEEP Company (São Paulo State) Main Developments Monitoring applications in real time Applications for off-line disturbance analysis 6 Project 2 ( ) Objective Development of a system for automatic evaluation of dynamic security based on security regions and synchronized phasor measurements
7 MedFasee ONS Project ( ) Partner National System Operator (ONS) Objective Application of synchronized phasor measurement data for the analysis of the dynamic performance of the Brazilian Interconnected Power System (BIPS) 7
8 MedFasee Project Applications Development Basic Applications (BA): Acquisition and processing of phasor data (PDC) Visualization tools for the dynamic behavior assessment using off-line and real time data Synchronized recording and analysis of perturbation data Monitoring Applications (MA): Off-line and real time analysis of electromechanical oscillations "Basic" Subsidies for other applications Specials Model Validations and Simulations Control and Protection Applications (CPA) Control for damping critical oscillation modes Special Applications (SA): Hybrid dynamic simulation Validation of simulation models Estimation of line parameters Fault location Monitoring Applications" Dynamic information of electrical systems " Control and Protection" Preventive, Corrective and Restorative Actions 8
9 Selected Cases 1 - Disturbance in BIPS (15/12/2012) Trip of 5 generation units in Itumbiara Hydroelectric Plant Load interruption (16,26% of BIPS) ~8.000 MW in S/SE ~1.704 MW in MG, MT, AC/RO e GO 9
10 Selected Cases 2 - Sustained oscillations in AC-RO November 12 th, 2014 Islanding 18h42min20s Resynchronization 18h45min10s 59,2 Hz 60,8 Hz PSS blocked PSS operation PSS blocked Resynchronization Zoom Islanding 10
11 Selected Cases 3 - Sustained oscillations in AC-RO November 12 th, 2014 Period: 19h08min21s 19h17min05s 11
12 Selected Cases 3 - Sustained oscillations in AC-RO November 12 th, 2014 Period: 19h08min21s 19h17min05s (UTC) Period 1: 19h10min00s 19h10min59s 0,58 Hz Period 2: 19h14min00s 19h14min59s 0,55 Hz 12
13 Selected Cases 3 - Sustained oscillations in AC-RO November 12 th, 2014 Period: 19h08min21s 19h17min05s (UTC) Period: 19h16min35s 19h17min05s 13 Prony Analysis Frequency: 0,53 Hz Damping Rate: 1,7 %
14 Dif. Angular (graus) Dif. Angular (graus) Dif. Angular (graus) Selected Cases 4 - Sustained oscillations in Mato Grosso do Sul Oscillations in Mato Grosso do Sul (MS), observed at the PMU installed in Campo Grande (State capital): May, 2012 Angle Difference: UFSC (Florianópolis) x UFMS (Campo Grande) Diferença angulares. Ref.:UFSC [10f/s] Diferença angulares. Ref.:UFSC [10f/s] UFMS UFMS Início Fim Tempo(h) - Início:05/05/ :00:00 (UTC) Diferença angulares. Ref.:UFSC [10f/s] UFMS Tempo(h) - Início:05/05/ :00:00 (UTC) First period: 1h27min + 30min (UTC) Início Tempo(h) - Início:05/05/ :00:00 (UTC) Restart: 2h23min + 4,5 days (UTC)
15 Selected Cases 4 - Sustained oscillations in Mato Grosso do Sul Ambient Data acquired in 05/05/2012 DFT Stochastic Balanced Realization (SBR) Frequência Amortecimento Tempo(h) - Início:05/05/ :00:00 (UTC) The DFT results are coherent with the SBR results Importance of employing more than one methodology
16 Selected Cases 4 - Sustained oscillations in Mato Grosso do Sul Ambient Data acquired in: 06/05/ /05/
17 Dif. Angular (graus) Selected Cases 4 - Sustained oscillations in Mato Grosso do Sul Ambient Data acquired in: 09/05/2012: Disappearance of oscillations at 13h58min (UTC) Diferença angulares. Ref.:UFSC [10f/s] 24 UFMS Final das oscilações Tempo(h) - Início:09/05/ :00:00 (UTC) Cause: Associated with biomass driven generators in Mato Grosso do Sul
HPPA. Online Security Assessment in Brazil. J. Jardim June 2-5,2013. Software & Information Systems
Online Security Assessment in Brazil J. Jardim June 2-5,2013 Software & Information Systems Topics Brazilian System Overview DSA Characteristics Application and Cases New Developments Brazilian System
More informationSynchrophasor Applications on Brazilian Interconnected System
Synchrophasor Applications on Brazilian Interconnected System International Conference on Phasor Measurements Applications June, 2006 Rui Menezes de Moraes Héctor Andrés Rodriguez Volskis Introduction
More informationRTDMS CAISO TRAINING SESSION
Consortium for Electric Reliability Technology Solutions Real-Time Dynamics Monitoring System (RTDMS ) RTDMS CAISO TRAINING SESSION January 31, 2006 Manu Parashar & Jim Dyer Electric Power Group (EPG)
More informationSDG&E s Accomplishments and Future Plans
SDG&E s Accomplishments and Future Plans Tariq Raman and Subbu Sankaran San Diego Gas & Electric Work Group Meeting October 23-24, 2018 San Diego Gas & Electric San Francisco SDG&E Los Angeles San Diego
More informationSynchrophasor activities in Brazil
Synchrophasor activities in Brazil September 6, 2007 Montreal Canada Rui Moraes & Héctor Voskis Brazilian National Electrical System Operator 2 Introduction Brazil Territory: 8.5 8.5 million km km 2 20%
More informationTechnology Innovation Delivering Value to BPA Organized, Disciplined, Focused
B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Technology Innovation Delivering Value to BPA Organized, Disciplined, Focused Keeping the Lights on for the Long Term The Basics Bonneville Power
More informationOVERVIEW: KEY APPLICATIONS
WECC Reliability Coordinator Website OVERVIEW: KEY APPLICATIONS presented by Kirk Stewart, Manager Applications Agenda WECCRC.org Website Wide-Area Views (WAV) Historical Data Archiving and Reporting My
More informationSynchrophasors and Next Generation Energy Management Systems (EMS)
Synchrophasors and Next Generation Energy Management Systems (EMS) Manu Parashar Celebrating the Visions of Synchrophasor Pioneers: Arun Phadke and Jim Thorp May 9 th, 2013 Analog Data Acquisition Changing
More informationSIGUARD System for Phasor Data Processing
SIGUARD System for Phasor Data Processing Real Time Visualization and Disturbance Recording Dan Murray Siemens Energy, Inc. System Description SIGUARD is a software-based Phasor Data Concentrator Data
More informationWide Area Monitoring System Planning, Strategy and Implementation in Thailand s Power Grid
Sept.3-5, 2013, China AORC-B-3-0002 CIGRE-AORC 2013 Wide Area Monitoring System Planning, Strategy and Implementation in Thailand s Power Grid W. PIMJAIPONG L.SURAPONGPUN Electricity Generating Authority
More informationReal Time Requirements and Closed-Loop Testing of Wide Area Protection and Control Schemes
XIII SIMPÓSIO DE ESPECIALISTAS EM PLANEJAMENTO DA OPERAÇÃO E EXPANSÃO ELÉTRICA XIII SEPOPE 18 a 21 de Maio 2014 May 18 th to 21 st 2014 FOZ DO IGUAÇU (PR) - BRAZIL XIII SYMPOSIUM OF SPECIALISTS IN ELECTRIC
More informationKarl Iliev, San Diego Gas & Electric Company
INTEGRATING DER THROUGH DISTRIBUTION SYNCROPHASORS Karl Iliev, San Diego Gas & Electric Company 2002 San Diego Gas and Electric Co. and Southern California Gas Company. All copyright and trademark rights
More informationTask Force Code System Dynamic Issues for the synchronous zone of Continental Europe
Task Force Code System Dynamic Issues for the synchronous zone of Continental Europe - Final - RG-CE System Protection & Dynamics Sub Group 14 September 2017 Table of Contents 1. Introduction... 3 2. Inertia
More informationWAProtector Power System Wide Area Monitoring Protection and Control
WAProtector Power System Wide Area Monitoring Protection and Control Bojan Mahkovec, Dr. Tadeja Babnik ELPROS, Slovenia Flavio Rabello NOVAKOASIN, Brasil Brasil April 2010 1 Presentation outline Presentation
More informationPhasor Technology Research Road Map to Improve Grid Reliability and Market Efficiency. Presented to TAC on April 5, 2005 and PAC on April 22, 2005
Phasor Technology Research Road Map to Improve Grid Reliability and Market Efficiency Presented to TAC on April 5, 2005 and PAC on April 22, 2005 Background Power Grid has evolved from a vertically integrated
More informationApplications and Analysis Tools for Monitoring Dynamics on the Grid
1 Applications and Analysis Tools for Monitoring Dynamics on the Grid Phil Overholt Program Manager Office of Electricity Delivery and Energy Reliability (OE) Energy Infrastructure Modeling and Analysis
More informationOptimal Power System Management with SIGUARD
Optimal Power System Management with SIGUARD Unrestricted www.siemens.com/siguard SIGUARD Suite Increase of Observability, Controllability, Security and Operator Awareness SIGUARD PDP Phasor Data Processing
More informationWISP. Western Interconnection Synchrophasor Program. Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 17-18, 2012
WISP Western Interconnection Synchrophasor Program Vickie VanZandt & Dan Brancaccio NASPI Work Group Meeting October 17-18, 2012 1 Acknowledgement and Disclaimer Acknowledgment: This material is based
More informationIn 2013 we are completing 25 years of activity, in which period we participate in the implementation of important projects in the area of electric
WELCOME ELTMAN is an engineering company working in the areas of engineering studies, basic and detailed projects and field services, related to energy and transportation markets. Our main focus is on
More informationResults 1Q11 and Strategic Framework. June, 2011
Results 1Q11 and Strategic Framework June, 2011 1 Agenda Regional Data Corporate Structure Operating Performance Financial Results Capex Sustainability Actions Strategic Framework 2 About Brazil 2010 Brazil
More informationSCE WASAS Combined Disturbance Fault Recorder (DFR) and Phasor Measurement Unit (PMU) Specifications. Anthony Johnson
SCE WASAS Combined Disturbance Fault Recorder (DFR) and Phasor Measurement Unit (PMU) Specifications Anthony Johnson Anthony.Johnson@SCE.com Summary Specifications for combined DFR/PMU to be used as part
More informationSmart Grid Operations - Clemson University Research, Education and Innovation-Ecosystem Opportunities
Smart Grid Operations - Clemson University Research, Education and Innovation-Ecosystem Opportunities G. Kumar Venayagamoorthy, PhD, FIET, FSAIEE Duke Energy Distinguished Professor & Director & Founder
More informationPJM Interconnection Smart Grid Investment Grant Update
PJM Interconnection Smart Grid Investment Grant Update Bill Walker walkew@pjm.com NASPI Work Group Meeting October 12-13, 2011 Acknowledgment: "This material is based upon work supported by the Department
More informationMeeting the Demands of Power Hungry China through a Real-time Data Driven Enterprise Platform
Meeting the Demands of Power Hungry China through a Real-time Data Driven Enterprise Platform Place your company logo in this area. Then delete this text box FibrLINK Dr. Jun Zha EMS Users Conference San
More informationEvolution of Control for the Power Grid
Evolution of Control for the Power Grid Anjan Bose Washington State University Pullman, Washington, USA University of Seville Seville, Spain June 17, 2016 THE INTERCONNECTED GRID Economics Transfer electric
More informationElectric Transmission and Distribution Future R&D Needs
Electric Transmission and Distribution Future R&D Needs Planning, Operation, Control, and Visualization The Center for Advanced Power Systems Florida State University, Tallahassee, Florida February 1,
More informationDr. Yi Hu, Dr. Damir Novosel Quanta Technology LLC
Brazil CIGRE B5 PDC Workshop Considerations and Requirements of PDCs for WAMPAC Systems Dr. Yi Hu, Dr. Damir Novosel Quanta Technology LLC Rio de Janeiro, Brazil April 6, 2010 Presentation Outline Global
More informationPerry. Lakeshore. Avon. Eastlake
Perry Lorain Avon Lakeshore Eastlake Ashtabula Mansfield Sammis Beaver Valley Conesville Tidd Burger & Kammer Muskingum Perry Lorain Avon Lakeshore Eastlake Ashtabula Mansfield Sammis Beaver Valley Conesville
More informationChapter 2 State Estimation and Visualization
Chapter 2 State Estimation and Visualization One obvious application of GPS-synchronized measurements is the dynamic monitoring of the operating conditions of the system or the dynamic state estimation
More informationImplementation of Wide Area Monitoring System for interconnected power system in India
REETA-2K16 ǁ PP. 400-405 Implementation of Wide Area Monitoring System for interconnected power system in India B.Lahari 1, K.Gireeshma 2, B.S.Lokasree 3 1 (Electrical Power Systems, Sree Vidyanikethan
More informationDigital Transformation of Power Delivery
Digital Transformation of Power Delivery Keynote Speech Professor Saifur Rahman, PhD Virginia Tech, USA IEEMA Engineer Infinite Conference, Delhi NCR, India, 14 March 2018 Traditional Electricity Delivery
More informationSituational Intelligence in Control Centers
Situational Intelligence in Control Centers G. Kumar Venayagamoorthy, PhD, FIET, FSAIEE Duke Energy Distinguished Professor & Director of the Real-Time Power and Intelligent Systems Laboratory Holcombe
More informationMultilin P30 Phasor Data Concentrator
Multilin P30 Phasor Data Concentrator Secure high performance Phasor Data Concentrator (PDC) for wide area monitoring and dynamic disturbance analysis KEY BENEFITS Reduce deployment and operation cost
More informationNorth American SynchroPhasor Initiative (NASPI) Overview
North American SynchroPhasor Initiative (NASPI) Overview Data Exchange Panel ipcgrid 2013 hosted by Pacific Gas & Electric March 28, 2013 Jeff Dagle, PE Chief Electrical Engineer Advanced Power and Energy
More informationADM Commitment to No Deforestation, No Peat and No Exploitation
ADM Commitment to No Deforestation, No Peat and No Exploitation Policy Implementation Q3 2016 Soy Progress Report In Partnership with The Forest Trust Introduction ADM committed to Our No Deforestation,
More informationMultifunctional System Protection for Transmission Lines Based on Phasor Data
Multifunctional System Protection for Transmission Lines Based on Phasor Data Igor Ivanković Croatian transmission system operator HOPS igor.ivankovic@hops.hr Igor Kuzle University of Zagreb, Faculty of
More informationPower System Resilience & Reliability. Robert W. Cummings Senior Director of Engineering and Reliability Initiatives i-pcgrid March 28, 2017
Power System Resilience & Reliability Robert W. Cummings Senior Director of Engineering and Reliability Initiatives i-pcgrid March 28, 2017 NERC, Reliability, & Resilience NERC has addressed reliability
More informationAchieving Smarter Grid Operation With On-Line DSA Technology
Achieving Smarter Grid Operation With On-Line DSA Technology Powercon 2014 October 20-22, 2014, Chengdu, China Lei Wang Powertech Labs Inc. 12388 88 th Avenue Surrey, BC, Canada A very simple version of
More informationCPqD Experience Conformity Assessment and Interoperability
6/12/2012 CPqD Experience Conformity Assessment and Interoperability ITU Forum on Conformance and Interoperability for the Americas region Agenda CPqD Who we are CPqD Approach for Conformity Assessment
More informationIndian Power Grid Developments
Indian Power Grid Developments Rathin Basu Country President, Alstom Grid, March 25 th 2015 Evolution of Voltage level of Indian Grid kv Anticipated the evolution & Timely Investment in Indian Facilities
More informationBig Data Analytics: Research Needs. Ali Ghassemian
Big Data Analytics: Research Needs Ali Ghassemian April 28, 2016 Plan DOE s Grid Modernization Initiative (GMI) represent a comprehensive effort to help shape the future of our nation s grid and solve
More informationReal-time visualization for detecting and solving power system challenges
SEL-5078-2 synchrowave Central Software Real-time visualization for detecting and solving power system challenges Automatically detect transients induced by renewable generation. Gain power system insight
More informationNew illustration is coming
New illustration is coming MINING USER CONFERENCE, MAY 3-5, 2017 Vale Itabira Case Operating and maintaining digital substations based on IEC 61850 Leandro Monaco, Global Product Manager Operations & Electrical
More informationSynchrophasor Technology and Systems
PNNL-SA-106051 Synchrophasor Technology and Systems Jeff Dagle, PE Chief Electrical Engineer and Team Lead Electricity Infrastructure Resilience Pacific Northwest National Laboratory Richland, Washington
More informationWAMS Analytics for Electrical Transmission Systems
WAMS Analytics for Electrical Transmission Systems Prof. S A Soman Indian Institute of Technology Bombay August 7, 2013 1 of 17 Agenda Synchrophasor analytics architecture List of WAMS analytics to be
More informationAlways an eye to security
Always an eye to security SIGUARD the perfect supervision of your power system www.siemens.com/siguard Answers for infrastructure and cities. Keeping the overview SIGUARD is a suite of innovative software
More information10 th Annual University of Pittsburgh Electric Power Industry Conference
10 th Annual University of Pittsburgh Electric Power Industry Conference System Studies for Grid Level Integration of Power Electronic Devices Presentation November 16, 2015 1:30 PM Session Adam R. Sparacino
More informationImplementation of phasor measurement technology at Eskom
Implementation of phasor measurement technology at Eskom by Reshin Moodley and Brian Berry, Eskom The modern era of power delivery is faced with many challenges due to decreased reserves, increased use
More informationAlarming and Operations of openpdc at ISO-NE
A U G 1 4, 2 0 1 3 A T L A N T A, G A Alarming and Operations of openpdc at ISO-NE Qiang Frankie Zhang, Patrick Pentz (Developer) Outline Project Overview Project Status Development Challenges Discussion
More informationPMU Communication Network Analysis
PMU Communication Network Analysis what - why - how with PMU existence CS620: New Trends in Information Technology Course Seminar Presentation By Gelli Ravikumar & Kedar Khandeparkar Roll No. 114070015
More informationAdvanced Real-Time Situational Awareness Sourced from Synchrophasor Data
Advanced Real-Time Situational Awareness Sourced from Synchrophasor Data Faster than the Eye, not faster than PI Presented by Kliff Hopson, Bonneville Power Administration Jeff Hopper, Casne Engineering,
More informationStudy of Transient Stability Improvement of IEEE 9-Bus System by using SVC
Study of Transient Stability Improvement of IEEE 9-Bus System by using SVC Rathnasagar Rangu 1, Poonam Upadhyay 2 1 PG Student, VNR VJIET, Hyderabad, India 2 Professor, VNR VJIET, Hyderabad, India Abstract
More informationFive Year Synchrophasor Plan NOVEMBER 2011
Five Year Synchrophasor Plan NOVEMBER 2011 SynchrophasorReport2011.indd 1 12/22/2011 11:07:36 AM Table of Contents 1.0 Overview...2 2.0 Background...3 3.0 Key Activities...5 3.1 Infrastructure...5 3.1.1
More informationWIDE-AREA CONTROL OF POWER SYSTEMS USING CLOUD-IN-THE-LOOP FEEDBACK
WIDE-AREA CTROL OF POWER SYSTEMS USING CLOUD-IN-THE-LOOP FEEDBACK Matthew Weiss Jianhua Zhang Aranya Chakrabortty North Carolina State University Department of Electrical and Computer Engineering Raleigh,
More informationHVDC in CSG Challenges and Solutions
HVDC in CSG Challenges and Solutions LI, Licheng lilc@csg.cn LI, Peng lipeng@csg.cn China Southern Power Grid Co., Ltd June 2013 1 Outline I. Overview of CSG II. Overview of HVDC&UHVDC in CSG III. Challenges
More informationEvaluation of Latent Similarity Search in DSS4LA by Using Big PMU Data
Evaluation of Latent Similarity Search in DSS4LA by Using Big PMU Data i-pcgrid Workshop 2017 3/31/2017 Hitachi America, Ltd. Big Data Lab Mika Takata Panitarn (Joseph) Chongfuangprinya Contents Introduction
More informationA HYDRAULIC ROBOT APPLIED TO POWER LINE INSULATOR MAINTENANCE. Prof Daniel Martins, UFSC
A HYDRAULIC ROBOT APPLIED TO POWER LINE INSULATOR MAINTENANCE Prof Daniel Martins, UFSC daniel.martins@ufsc.br Authors Martins, Daniel, daniel.martins@ufsc.br De Negri, Victor Juliano, victor@emc.ufsc.br
More informationInternational Internet Connectivity Brazilian Experience
ITU Workshop on Apportionment of Revenues and International Internet Connectivity (Geneva, Switzerland, 23-24 January 2012) International Internet Connectivity Brazilian Experience Salerme Oliveira, Operational
More informationNERC Event Analysis Update Webinar. Hassan Hamdar Chair, Event Analysis Subcommittee October 20, 2016
NERC Event Analysis Update Webinar Hassan Hamdar Chair, Event Analysis Subcommittee October 20, 2016 Webinar Agenda ERO Event Analysis Process Update Lesson Learned Presentation from Entity ERO Lessons
More informationNorth American SynchroPhasor Initiative An Update of Progress
North American SynchroPhasor Initiative An Update of Progress Jeff Dagle Pacific Northwest National Laboratory jeff.dagle@pnl.gov Abstract In 2007, the U.S. Department of Energy (DOE) and the North American
More informationStandard EOP Disturbance Reporting
A. Introduction 1. Title: Disturbance Reporting 2. Number: EOP-004-1 3. Purpose: Disturbances or unusual occurrences that jeopardize the operation of the Bulk Electric System, or result in system equipment
More informationIncorporating PMUs in Power System State Estimation for Smart Grid EMS
1 Panel 3: Experiences in Incorporating PMUs in Power System State Estimation, IEEE PES General Meeting, Denver, USA, July 26-30 Incorporating PMUs in Power System State Estimation for Smart Grid EMS Boming
More informationSouthern Company Smart Grid
Southern Company Smart Grid Smart Grid Investment Grant Update July 25, 2011 Southern Company Southern Company is one of the nations largest generators of electricity Has 4.4 million retail customers across
More informationPJM Interconnection Smart Grid Investment Grant Update
PJM Interconnection Smart Grid Investment Grant Update Bill Walker walkew@pjm.com NASPI Work Group Meeting October 22-24, 2013 Acknowledgment: "This material is based upon work supported by the Department
More informationThe strategic plan of HEDNO for the Non- Interconnected Islands Investments Smart Islands Innovation
The strategic plan of HEDNO for the Non- Interconnected Islands Investments Smart Islands Innovation Ioannis Margaris Vice-Chairman BoD Hellenic Electricity Distribution Network Operator (ΔΕΔΔΗΕ - HEDNO)
More informationA Case for Multi-Function PMU
A Case for Multi-Function PMU Harish I. Mehta Mehta Tech, Inc. www.mehtatech.com NASPI Chattanooga, TN Meeting PMU Definition PMU is generally defined as: IEEE C37.118 compliant device Time synchronized
More informationIJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 10, 2015 ISSN (online):
IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 10, 2015 ISSN (online): 2321-0613 Comparison of Shunt Facts Devices for the Improvement of Transient Stability of Two Machine
More informationWide-Area Reliability Monitoring and Visualization Tools
OE Visualization and Controls Peer Review Wide-Area Reliability Monitoring and Visualization Tools Carlos Martinez CERTS - Electric Power Group 21 October 2008 Washington, D.C. Presentation Outline Research
More informationPower System Monitoring Recorder TESLA 3000
Power System Monitoring Recorder TESLA 3000 Product Overview TESLA 3000 is an easy-to-use and cost-effective, stateof-the-art, multi-time frame (simultaneous) power system recording monitor. The optional
More informationPrivacy Security Trust in the light of the Brazil EU partnership
Privacy Security Trust in the light of the Brazil EU partnership IBE Institute for Studies Brazil- Europe EPUSP Escola Politécnica da USP UFU Universidade Federal de Uberlândia Prof. Dr. Sergio Takeo
More informationIMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS
IMPROVING POWER SYSTEM RELIABILITY USING MULTIFUNCTION PROTECTIVE RELAYS Armando Guzmán Schweitzer Engineering Laboratories, Inc. Pullman, WA 99163 A reliable power system maintains frequency and voltage
More informationGrid Operations - Program 39
Grid Operations - Program 39 Program Description Program Overview In many ways, today's power system must be operated to meet objectives for which it was not explicitly designed. Today's transmission system
More informationIMPLEMENTATION OF A WIDE-AREA MONITORING SCHEME FOR THE INDIAN POWER SYSTEM
IMPLEMENTATION OF A WIDE-AREA MONITORING SCHEME FOR THE INDIAN POWER SYSTEM Peter Harding, GE Grid Solutions UK, peter.harding@ge.com Ritesh Bharat, GE Grid Solution India, ritesh.bharat@ge.com A.Gillies,
More informationHigh impedance protection relay
High impedance protection relay Page 1 Issued: April 1999 Status: New Data subject to change without notice Features High impedance type differential current earth-fault protection, so called restricted
More informationNASPI Work Group meeting April 24-26, 2018 Albuquerque, NM
NASPI Work Group meeting April 24-26, 2018 Albuquerque, NM Pavel Kovalenko Viktor Litvinov from data to action Premium Information Services from Data to Action Design, Develop and Deploy digital transformation
More informationPower System Monitoring Recorder
Power System Monitoring Recorder TESLA 4000 Model 4000 Model 4003 Product Overview TESLA 4000 is an easy-to-use and cost effective, state of the art, multi-time frame (simultaneous) power system monitoring
More informationExposing vulnerabilities in electric power grids: An experimental approach
Exposing vulnerabilities in electric power grids: An experimental approach International Journal of Critical Infrastructure Protection Luigi Coppolino, S. D Antonio, and L. Romano (Tropea, 24-26 Settembre
More informationEvolution of Control for the Power Grid
Evolution of Control for the Power Grid Anjan Bose Washington State University Pullman, WA, USA PaiFest In Honor of Prof. M. A. Pai Urbana-Champaign, IL October 15, 2015 The Past (before 1960s) Hard
More informationWide Area Monitoring and Control
Wide Area Monitoring and Control Schweitzer Engineering Laboratories André du Plessis Copyright SEL 2015 SEL Headquarters: WA US Manufacturing: ID, IL, WA Invent, Design, Build, and Support the Systems
More informationIEEE PES Initiatives and Industry Role in Standards
1 Smart Solutions, Practical Results IEEE PES Initiatives and Industry Role in Standards Dr. Vahid Madani, PG&E Dr. Damir Novosel, IEEE PES President March 31, 2016 1 Outline IEEE Benefits Need for Standards
More informationSynchrophasor Data Management Survey
Synchrophasor Data Management Survey The purpose of this questionnaire is to gain an understanding of the volume of data being generated by your company, how this data is being stored, used and archived.
More informationSynchrophasor Fact Sheet
Synchrophasors and SEL For more than 25 years, Schweitzer Engineering Laboratories, Inc. (SEL) has delivered reliable, high-quality solutions that lead the electric power industry in price, features, innovation,
More informationSacramen Sacr t amen o t Municipal Utility Dis t Dis rict t SMUD May Ma 10,
Sacramento Municipal Utility District SMUD May 10, 2010 1 SMUD Facts and Figures 900 Sq. Miles Service Area 585,500 Customers 1.4 million Area Population 10 Bulk Substations 473 Miles of Transmission Lines
More informationPSSS/PSAC Engineering, Muhammad Adil, Substation Automation Systems. ABB Group October 29, 2014 Slide 1
PSSS/PSAC Engineering, Muhammad Adil, 30-10-2014 Substation Automation Systems October 29, 2014 Slide 1 CONTENT INTRODUCTION IEC61850 ABB s BAY LEVEL SOLUTIONS ABB s STATION LEVEL SOLUTIONS ABB s AS A
More informationPower System Monitoring Recorder. Product Overview. 10 Year WARRANTY
Power System Monitoring TESLA 4000 Product Overview TESLA 4000 is an easy-to-use, state of the art, multi-time frame (simultaneous) power system monitoring recorder. Its integrated Phasor Measurement Unit
More informationTransmission Interconnection Handbook, Appendix F. System protection, generation interconnection, substation test, and telecommunication personnel
Utility Bulletin: TD-1013B-002 Publication Date: 07/03/2012 Rev: 0 Direct Transfer Trip (DTT) Telecommunication Options Summary Interconnection partners (customers) are requesting additional options for
More informationManaging Database Services: An Approach Based in Information Technology Services Availabilty and Continuity Management
ISSN: 2468-4376 Managing Database Services: An Approach Based in Information Technology Services Availabilty and Continuity Management 1 Universidade de Fortaleza, BRAZIL Leonardo Bastos Pontes 1 *, Adriano
More informationSCADA SYSTEM ROLE IN A DEREGULATED ENVIRONMENT. Alexandria Electricity Distribution Company
SCADA SYSTEM ROLE IN A DEREGULATED ENVIRONMENT Galal Ahmed Tarek Emara Nader Abdelghani Amira Taha Alexandria Electricity Distribution Company SCADA SYSTEM ROLE IN A DEREGULATED ENVIRONMENT Introduction
More informationTime Synchronization and Standards for the Smart Grid
Time Synchronization and Standards for the Smart Grid Tom Nelson National Institute of Standards and Technology 2011 NIST - ATIS - Telcordia Workshop on Synchronization in Telecommunication Systems (WSTS
More informationApplications on openpdc platform at Washington State University
Applications on openpdc platform at Washington State University Mani V. Venkatasubramanian Washington State University Pullman WA WSU projects OMS - Oscillation Monitoring System Stand-alone system for
More informationDemand for sustainable power is growing worldwide. Energy producers are broadening their offerings for a quickly evolving marketplace.
Power delivery Demand for sustainable power is growing worldwide. Energy producers are broadening their offerings for a quickly evolving marketplace. Forward-thinking power grid design This evolution has
More informationSynchro-check relay. Application
Issued: April 1999 Status: Updated Version: B/08.11.2001 Data subject to change without notice Features Two identical operation stages allowing the closing conditions of two separate circuit breakers to
More informationHigh Impedance Protection Relay SPAE010, SPAE011. Product Guide
SPAE010, SPAE011 SPAE010, SPAE011 1MRS750383-MBG Issued: April 1999 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features High impedance type differential current earth-fault
More information9 th Electricity Conference at CMU
Power Systems/Communication System Co-Simulation and Experimental Evaluation of Cyber Security of Power Grid Yi Deng, Sandeep Shukla, Hua Lin, James Thorp February 5, 2014 9 th Electricity Conference at
More informationSensitive Earth-fault Relay SPAJ 111 C. Product Guide
Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent
More informationFeeder protection relay SPAA 121 C. Product Guide
Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase
More informationDeveloping a Roadmap for A Smart(er) and Strong Transmission Grid
Developing a Roadmap for A Smart(er) and Strong Transmission Grid By: Navin Bhatt Manager, Advanced Transmission Studies & Technologies American Electric Power (AEP) PSERC 2009 Summer Workshop Breckenridge,
More informationImproving data quality in PSE&G s synchrophasor network PING YE PHD PSE&G ZACHARY HARDING PSE&G (IBRIDGE)
Improving data quality in PSE&G s synchrophasor network PING YE PHD PSE&G ZACHARY HARDING PSE&G (IBRIDGE) Synchrophasors at PSE&G PJM SynchroPhasor Project ~Circa 2008 DOE PJM AEP AP BGE ComEd DOM DUQ
More informationA Virtual Smart Grid
A Virtual Smart Grid Real-Time Simulation for Smart Grid Control and Communications Design IIT IS GENERALLY RECOGNIZED THAT A HIGH-BANDWIDTH and highly available networked communication system should overlay
More informationAlex Soares de Moura
Alex Soares de Moura alex@rnp.br GLIF Americas (GLIF-A) Community Meeting Wednesday, October 2, 2013 (1:30 4:30 pm) Parallel and Distributed Computing Centre School Of Computer Engineering, Nanyang Technological
More information