1 BRIT QC May 2007 Release UM-BQC

2

3 Table of Contents Notices and Copyrights Notice This document is subject to change without notice and does not represent a commitment by BRIT Systems, Inc. The information set forth in this document and all rights in and inventions disclosed herein and the patents that might be granted thereon disclosing or employing the materials, methods, techniques, or apparatus described herein are the exclusive property of BRIT Systems, Inc. Copyright Copyright 2007, BRIT Systems, Inc. All rights reserved. Printed in the United States of America Trademarks BRIT (Beyond Roentgen Imaging Technology), BRIT Systems, Inc., Roentgen RIS, and the Pincher-Man logo/icon are trademarks of BRIT Systems, Inc. Microsoft and MS-Windows are registered trademarks of Microsoft Corporation. All other product names or trademarks mentioned herein are the property of their respective owners BRIT QC User Manual 1

4 Table of Contents Revision Records Revision Record for User Manual Rev. # Date Sections/Pages Affected Change Authority Author Release Number 1 May 2004 All Initial Issue Unknown 2 Aug 2004 All Updates Unknown 3 Sep 2004 All Updates Unknown 4 Feb 2007 All Updates T. Harris May 2007 All Re-release T. Harris Copyright 2007 Technical Publications Department BRIT Systems, Inc. BRIT Systems, Inc. Printed in U.S.A Hi Line Drive, Suite A All rights reserved Dallas, Tx BRIT QC User Manual 2

5 Table of Contents Table of Contents I. SECTION 1 - INTRODUCTION...1 STARTING THE BRIT QC APPLICATION...1 PATIENT LIST WINDOW...2 EXAM VIEWING WINDOW...7 II. SPLIT A SERIES...9 III. SPLIT A STUDY...13 IV. MOVE IMAGES TO ANOTHER SERIES...17 V. MOVE IMAGES TO ANOTHER STUDY...21 STEP 1: SPLIT THE IMAGES INTO A NEW SERIES...22 STEP 2: MOVE THE NEW SERIES TO THE CORRECT STUDY...24 STEP 3: MOVE THE IMAGES TO THE CORRECT SERIES...26 VI. MOVE SERIES TO ANOTHER STUDY...29 VII. MOVE STUDY TO ANOTHER PATIENT...31 VIII. MOVE SERIES TO ANOTHER PATIENT...35 IX. MOVE IMAGES TO ANOTHER PATIENT...39 STEP 1: SPLIT THE IMAGES INTO A NEW SERIES...40 STEP 2: MOVE THE NEW SERIES TO A NEW STUDY...42 STEP 3: ASSIGN THE NEW STUDY TO THE CORRECT PATIENT...44 STEP 4: MOVE THE SERIES TO THE CORRECT STUDY...46 STEP 5: MOVE THE IMAGES TO THE CORRECT SERIES...47 X. DELETE SERIES FROM A STUDY...51 XI. DELETE ENTIRE STUDY...53 XII. DELETE IMAGES FROM A STUDY...55 XIII. EDIT STUDY OR SERIES INFORMATION...57 EDIT THE STUDY INFORMATION...57 EDIT THE SERIES INFORMATION...58 BRIT QC User Manual 3

6

7 Chapter 1 - Introduction I. Section 1 - Introduction The QC Workbench is an easy to use Windows application that provides the Technologist with a tool to edit and manipulate studies that need manual intervention of for the purpose of moving images to another series or study, splitting a series or performing other quality functions. It provides a higher level of data integrity in a PACS archive by providing a modality worklist capability to those modalities that don t have this DICOM service natively. The QC Workbench receives orders from a modality worklist server and studies from modalities via a DICOM store. It attempts to match order information with study information. If a good match is found, the study is forwarded to a DICOM Storage SCP, normally the PACS archive. Otherwise, it is held for a technologist to match it up before sending. These tools provide the following functions for manual intervention: Split a series Split a study Move an image from one series to another series Combine multiple studies Move a series to another study Move images to another study Move study to another patient Delete images from the series Delete images from the study Changes the order of the images in a study Change the series description Correct patient demographic information WARNING: This application can change data already stored in an archive, so it must be used very carefully and ONLY by qualified authorized personnel. Starting the BRIT QC Application To start the BRIT QC application, click on the BRIT QC icon ( the desktop. The Login window opens. Enter the login name and click on the ) on BRIT QC User Manual 1

8 Chapter 1 - Introduction The BRIT Quality Workbench main window opens with the Events Log window, as shown below: This window displays each event as it occurs in the QC. Select the radio button next to: Pop-up on each new event Pop-up once per minute, max Stop popping up If Pop-up on each new event is selected, then this dialog box opens each time that a new event is logged, basically each time the Enter key is hit. If Pop-up once per minute, max is selected, then this dialog box opens once a minute showing all the new events that have been logged since the last time the Enter key is pressed. If Stop popping up is selected, this dialog box ceases to display during the current session. The log is shown in the lower portion of the window identifying the time, user, and event that occurred for each event. Select the desired option, and click on the Patient List Window The BRIT Quality Control workbench with the Patient Panel window is open behind the Event Log, as shown: Menus Viewer Toolbar Patient Select Buttons Patient List Image Viewing Area BRIT QC User Manual 2

9 Chapter 1 - Introduction The components of the Patient List window include: Viewer Toolbar Contains the buttons that allow quick access to viewer functions, including: Moves to the next image on the selected series. Moves to the previous image on the selected series. Moves to the next exam for the patient. Closes all studies that are open for the patient. Fits the image to the size of the window. Changes the image to a one-to-one pixel image of the original image. Magnifies the image to two times the original image size. Flips the image top to bottom. Flips the image left to right. Rotates the image 90 counterclockwise. Rotates the image 90 clockwise. Display all images in the series and puts them in the appropriate format so that all images fit the window. Acts as a toggle switch between three different views of the images in the series, which includes a single image, a montage of images, and the complete set of images in the series. Toggles the window to the selected image in a one-up format and back to all series displaying in individual windows. Sets the window/leveling of the selected image with preset values. Refreshes the window. Displays only the key images. Displays the Presentation State of the images. BRIT QC User Manual 3

10 Chapter 1 - Introduction Displays the report for the study. Menus - Contain drop-down menus to allow additional features, including: File Contains the following menus: Open Save WYSIWYG DICOM Print WYSIWYG Paper Print Report + WYSIWYG Print General Images to Send Exit Browser Opens the BRIT RIS window. Utilities Contains the following utilities: Halt Download Setup Personal profile Unit Profile Site Profile Erase Local Database Build DB from Local Images Delete Old Images Browser Patient List Contains the list of patients that are downloaded to the local disk. Print Contains the following options for printing: This Image This Image True Size Marked, 1 by 1 Marked, 1 by 2 Marked, 2 by 2 Marked, 2 by 3 Marked, 3 by 3 Marked, 3 by 4 Marked, 4 by 5 Marked, all in one Select Printer Print WYSIWYG Paper Print Report Plus WYSIWYG Status Contains the following options to select for study status: Set to Read Set to Unread Set to Pending Set to Critical Show Transfer Status Format Views Contains the following options for selecting the format to display the study: One View Only Shows a single view of an image in the selected series BRIT QC User Manual 4

11 Chapter 1 - Introduction All Views Shows all the series in the window One View per screen Shows a single view of an image in the selected series Next View Next Exam/Study Tiles Stack All All Views/Images Shows all images in every series with each series in its own window. Group Views Close All Format Images Contains the following options for selecting the format to display the images: Single View Shows a single view of an image in the selected series. Entire View Shows all the series in the window. 1 Wide 2 Wide 3 Wide 4 Wide 5 Wide 2 High Reorder Images Zoom Contains the following options for selecting the magnification factor for the selected image. Adjustable Fit to Window X1 X1.5 X2 X3 X4 X5 X0.5 Close All Provides a menu to indicate the steps that have been performed on the study. It can be closed by clicking on the button, left open and continue through the QC process by clicking on, or cancel the Close all option by clicking on. Help Provides assistance for the application including Mouse Special Usage Patient List Summary Browser Summary Complete Instruction Manual Frequently Asked Questions Patient Select Buttons Contains the following buttons: Reloads the list of patients that are locally downloaded. BRIT QC User Manual 5

12 Chapter 1 - Introduction Provides a list, as shown below of the filters that can be used to narrow the search list for specific patients, or types of patients. Users can search for exams by: Date Body Part Modality Selects a list of studies that needs to be QC s, studies that are accepted, or studies that are deleted. Provides information for the selected patient, which includes: Patient Name (Last, first, and middle) Patient ID Birthdate Gender Primary Physician Other Patient ID Provides information for the select patient s study: Accession Number Date Referring Physician Study Description Current Patient Location Requesting Service Study Comment Provides information for the select patients study series: Body Part Body Part Modifier (Left, Right, etc) Modality Series Description Study ID Institution Name Performs the QC activity on the selected patient or study. Patient List Area Shows a list of the patients currently download to the local disk. Image Viewing Area Shows the images for the selected patients. To download a patient exam to work with click on the Patient name in the list and click on the BRIT QC User Manual 6

13 Chapter 1 - Introduction Exam Viewing Window The viewing window opens with the patient exam displayed, and the same menus and toolbars. Menus Patient Info Image Header Viewer Toolbar Image Viewing Area BRIT QC User Manual 7

14 Chapter 1 - Introduction BRIT QC User Manual 8

15 Chapter 2 Split a Series II. Split a Series Occasionally a study is done in which the series contains images that should be split out into another series. When this happens the QC Workbench is used to split these images into a separate series. For example, in Study 1, Series 1, there are six images that need to be split out into a separate series in that study: Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 To create this new series, these six images are going to be split into a new series. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 Study 1 New Series 4 The final effect is that Study 1, Series 1 contains the 14 correct images, and a new series is created that contains the six images that were just split out. The other series in the Study were not affected. The following steps are used to split the series. 1) Select the patient from the patient list that has the study containing the series to split, and click on the 2) Select the series that contains needs to be split. 3) Display a single series by pressing the S (for Split) key on the keyboard. 4) Click on the button on the Toolbar to show all the images in the series to be split. 5) Click on the Utilities menu and select Split Series. Do you want to do this split series? BRIT QC User Manual 9

16 Chapter 2 Split a Series 6) A confirmation box appears providing instructions to mark the images that are to be put in the new series. Click on the 7) The Mark to Split box opens at the upper right. 8) To select individual images, click the left mouse button on each desired image that will be split into the new series. A appears in the box on each image as it is checked. To unmark the entire selected series, click on the To mark the entire selected series, click on the To unmark all series, click on the To mark all series, click on the To terminate the split series activity, and leave the series intact, click on the 9) Once all images are selected, click on the 10) A Verify Details dialog box opens for the user to confirm the action, as shown here: This dialog box shows a summary of the total number of images in the series, the number of images that were not selected, and the number of images selected. It also shows the name of the old series and the exact same name of the new series. The New description should be changed so that duplicate series names are avoided. Change the name of the New Series, and click on the New Series As the instructions indicate, a New series is created, and the marked images are moved from the Old sees to the New series. Selecting the activity. button terminates any BRIT QC User Manual 10

17 Chapter 2 Split a Series The images are now split into a new series; however, it is not saved on the archive yet. The window returns to display all the series. 11) From the Utilities menu, select Accept/Reject Images and a Mark Accept/Reject box displays, as shown here: 12) Verify that the new series has the correct images, and the old series retains the images that should remain in that series. 13) If all is correct and no other changes are to be made in the study, click on the If some images are left unmarked, the series will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 14) Click on the button when ready. 15) Click on the button to close the selected study, and another dialog box opens indicating the steps taken and verifying that the study should be archived. Click on the study. Click on the the study. button to accept the changes and archive the button to reject the changes and not archive 16) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 11

18 Chapter 2 Split a Series BRIT QC User Manual 12

19 Chapter 3 Split a Study III. Split a Study Occasionally a study is done in which multiple series need to be split into separate studies. This is done most frequently when multiple procedures are selected on the order, but the procedures are all included in one study. When this happens the QC Workbench is used to split these images into a separate study. For example, Study 1 needs to have Series 2 split to a separate study for the patient. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The process in this instance is that a new study is going to be created from the second series in Study 1. Study 1 Series 1 Study 1 Series 2 New Study 2 The final effect is that Study 1 contains the two series that were not affected, and the second series is moved into a separate Study 2. The following steps are used to split the study. 1) Select the patient from the patient list that has the study containing the series that need to be split into a different study, and click on the 2) From the Utilities menu, select Split Study. BRIT QC User Manual 13

20 Chapter 3 Split a Study 3) The SPLIT One Study Into Two Select series for each window opens, as shown here: 4) Click on the button, and click on the series that are to remain in the original study. Notice that as the series are selected the name is moved into the Original Study area. 5) Click on the button, and click on the series that are to be moved to a new study. Notice that as the series are selected the name is moved into the New Study area. 6) Click on the button to move the series as selected into the original or new studies. If any of the selections are incorrect, click on the button, and reselect the series for each. To terminate splitting series out of the study, click on the 7) Another dialog box opens asking if this is the correct action to take. It indicates the total number of series in the study, the number selected to remain in the original study, and the number to be moved to the new study. To confirm the action, click on the To cancel the action, click on the 8) The window now displays the old series in the left side, and the new series that is split out in the right side. BRIT QC User Manual 14

21 Chapter 3 Split a Study 9) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 10) Verify that the selected series have been correctly split. 11) Click on the button to accept all the images in all the series. If some images are left unmarked, the study will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 12) Click on the button when ready. 13) The selected images should now be split into two separate series. 14) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: If everything is correct, click on the changes and archive the study. If a series is incorrectly placed, click on the the changes and not archive the study. button to accept the button to reject 15) Another dialog box opens indicating the steps taken and verifying that the second study should be archived. It shows the number of series selected for Study #2, as shown here: If everything is correct, click on the changes and archive the study. button to accept the If a series is incorrectly placed, click on the the changes and not archive the study. button to reject 16) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 15

22 Chapter 3 Split a Study BRIT QC User Manual 16

23 Chapter 4 Move Images to Another Series IV. Move Images to Another Series Occasionally one or more images are associated with the incorrect series within the same patient study. When this happens the QC Workbench is used to move the images to the correct series. For example, Study 1 has five images that actually belong in Series 3. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The process in this example is that the five images that were incorrectly assigned to Series 1 need to be moved to Series 3. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The final effect is that Study 1, Series 1 contains the 15 correct images, and the other five images have been correctly moved to Series 3. The following steps are used to move an image to the correct series within the same study. 1) Select the patient from the patient list that has the study containing the images to move, and click on the 2) Select the series that contains the images to move by clicking on the series. 3) Display a single series by pressing the S (for Split) key on the keyboard. 4) Click on the button on the Toolbar to show all the images in the series. 5) From the Utilities menu, select Move Images. BRIT QC User Manual 17

24 Chapter 4 Move Images to Another Series 6) The Do you want to do this? box opens, as shown here. It provides the instructions on the steps to perform to select the images to move to a different series of the same study. If this is the correct action, click on the selected, click on the action. button to continue. If the wrong action was button to terminate the 7) To select individual images, click the left mouse button on each desired image that will be moved to the other series. Notice that when the image is selected a appears in the upper left corner of each selected image. Images that do have the are retained in the original series. 8) A Mark to Move dialog box in the upper right corner of the window. To unmark the entire selected series, click on the To mark the entire selected series, click on the To unmark all series, click on the To mark all series, click on the To terminate the split series activity, and leave the series intact, click on the 9) Select on this box, when all desired images are selected. BRIT QC User Manual 18

25 Chapter 4 Move Images to Another Series 10) A Move the marked images into a different series dialog box opens to allow the user to select the series where the selected image(s) are to be moved. 11) Click on the series where the selected image(s) are to be moved. 12) Click on the 13) A Verify Details dialog box opens for the user to confirm the action, as shown here: This dialog box shows a summary of the total number of images in the series, the number of images that were not selected, and the number of images selected. It also shows the name of the old series and the exact same name of the new series. The New description should be changed so that duplicate series names are avoided. Change the name of the New Series, and click on the As the instructions indicate, a New series is created, and the marked images are moved from the Old sees to the New series. Selecting the activity. button, terminates any 14) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 15) Verify that the selected images have been moved to the correct series. 16) Click on the button to accept all the images in all the series. If some images are left unmarked, the study will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 17) Click on the button when ready. 18) The selected images should now be moved into the correct series; however, they are not saved on the archive yet. BRIT QC User Manual 19

26 Chapter 4 Move Images to Another Series 19) Click on the button to close the selected study, and another dialog box opens indicating the steps taken and verifying that the study should be archived. Click on the study. button to accept the changes and archive the Click on the study. button to reject the changes and not archive the 20) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 20

27 Chapter 5 Move Images to Another Study V. Move Images to Another Study Occasionally a study is performed in which the series contains images that should be split out into another study. When this happens the QC Workbench is used to move these images into another study. For example, Series 2 in Study 1 has five images that should be assigned to Series 1 in Study 2. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 Study 2 Series 1 The process in this instance is that the images in Series 2 are split into a new series. The new series is moved to Study 2, and the five images are assigned to Series 1. Study 1 Series 1 Study 1 Series 2 Study 2 Series 1 The final effect is that Study 1 contains Series 1 and 3 completely, and the15 images that were originally in Series 2. The five images in Series 2 are now moved to Study 2, Series 1. To move the images from one study to another study, the following major steps must be taken: 1) Split the images into a new series. 2) Move the new series to the correct study. 3) Move the images to the correct series in the study. BRIT QC User Manual 21

28 Chapter 5 Move Images to Another Study Step 1: Split the Images into a New Series The following steps are used to move the images to another study. 1) Select the patient from the patient list that has the study containing the series to split, and click on the 2) Select the series that contains the images that needs to be split. 3) Display a single series by pressing the S (for Split) key on the keyboard. 4) Click on the button on the Toolbar to show all the images in the series to be split. 5) From the Utilities Menu, select Split Series. 6) A Do you want to do this? dialog box opens providing instruction to mark the images that need to be split into a separate series. Click on the Click on the is selected. button if the activity is correct. button if the incorrect series or study 7) Click on the image or images that are to be split into the new series. Notice that when the image is selected a appears in the upper left corner of each selected image. Images that have the are retained in the original series. 8) A Mark to Move dialog box appears in the upper right corner of the window. To unmark the entire selected series, click on the To mark the entire selected series, click on the To unmark all series, click on the To mark all series, click on the BRIT QC User Manual 22

29 Chapter 5 Move Images to Another Study To terminate the split series activity, and leave the series intact, click on the 9) Select on this box, when all desired images are selected. 10) A Verify Details dialog box opens for the user to confirm the action, as shown here: This dialog box shows a summary of the total number of images in the series, the number of images that were not selected, and the number of images selected. It also shows the name of the old series and the exact same name of the new series. The New description should be changed so that duplicate series names are avoided. Change the name of the New Series, and click on the As the instructions indicate, a New series is created, and the marked images are moved from the Old sees to the New series. Selecting the activity. button terminates any The images are now split into a new series; however, it is not saved on the archive yet. The window returns to display all the series. 11) From the Utilities men, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 12) Verify that the new series has the correct images, and the old series retains the images that should remain in that series. 13) If all is correct and no other changes are to be made in the study, click on the If some images are left unmarked, the series will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 14) Click on the button when ready. 15) Click on the button to close the selected study, and another dialog box opens indicating the steps taken and verifying that the study should be archived. Click on the study. button to accept the changes and archive the BRIT QC User Manual 23

30 Chapter 5 Move Images to Another Study Click on the button to reject the changes and not archive the study. 16) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. Step 2: Move the New Series to the Correct Study 1) Select the patient from the patient list that has the study containing the series to move, as well as the study where the series is to be moved, and click on the button for both studies. (Both studies need to be opened.) 2) Both studies are opened in the viewer, and are separated by a green border, as shown here. 3) Click on the study that is to be moved. 4) From the Utilities, select Move Series. 5) The Move The series shown into a different study dialog window opens, as shown here: 6) Click on the study shown in the lower portion of this window to select the study where this series is to be placed. 7) Click on the BRIT QC User Manual 24

31 Chapter 5 Move Images to Another Study 8) The Move Series to This Study dialog box opens, as shown here This box indicates that the series will be deleted from the selected study and moved to the selected study for the patient. 9) If this move is correct, click on the button to move the series into the selected study. If this move is incorrect, click on the move. button to terminate the 10) The window now displays the old study in the left side, and the other study on the right side that now contains the series that has been moved. 11) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 12) Verify that the selected series have been correctly moved. 13) Click on the 14) Click on the button when ready. 15) The selected series are now included in the other study. 16) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: BRIT QC User Manual 25

32 Chapter 5 Move Images to Another Study If everything is correct, click on the button to accept the changes and archive the study. If a series is incorrectly placed, click on the study. 17) Another dialog box opens indicating the steps taken and verifying that the second study should be archived. It shows the number of series selected for Study #2, as shown here: button to reject the changes and not archive the If everything is correct, click on the accept the changes and archive the study. button to If a series is incorrectly placed, click on the to reject the changes and not archive the study. button 18) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. Step 3: Move the Images to the Correct Series 1) Select the patient from the patient list that has the study containing the images to move, and click on the 2) Select the series that contains the images to move by clicking on the series. 3) Display a single series by pressing the S (for Split) key on the keyboard. 4) Click on the Utilities menu, and select Move Images. 5) The following dialog box opens indicating the steps that need to be taken next. If these steps are correct, click on the If the incorrect steps is selected, click on the button to terminate the action. To select individual images, click the left mouse button on each desired image that will be moved to the other series. Notice that when the image is selected a appears in the upper left corner of each selected image. Images that do have the are retained in the original series. BRIT QC User Manual 26

33 Chapter 5 Move Images to Another Study 6) A Mark to Move dialog box in the upper right corner of the window. 7) Select on this box, when all desired images are selected. 8) A Move the marked images into a different series dialog box opens to allow the user to select the series where the selected image(s) are to be moved. 9) Click on the series where the selected image(s) are to be moved. 10) Click on the 11) A Verify Details dialog box opens for the user to confirm the action, as shown here: This dialog box shows a summary of the total number of images in the series, the number of images that were not selected, and the number of images selected. It also shows the name of the old series and the exact same name of the new series. The New description should be changed so that duplicate series names are avoided. Change the name of the New Series, and click on the As the instructions indicate, a New series is created, and the marked images are moved from the Old series to the New series. Selecting the button, terminates any activity. 12) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 13) Verify that the selected images have been moved to the correct series. 14) Click on the button to accept all the images in all the series. If some images are left unmarked, the study will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. BRIT QC User Manual 27

34 Chapter 5 Move Images to Another Study 15) Click on the button when ready. 16) The selected images should now be moved into the correct series. 17) Click on the button to close the selected study, and another dialog box opens indicating the steps taken and verifying that the study should be archived. Click on the the study. button to accept the changes and archive Click on the the study. button to reject the changes and not archive 18) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 28

35 Chapter 6 Move Series to Another Study VI. Move Series to Another Study Occasionally a study is performed in which the series contains images that should be split out into another study. When this happens the QC Workbench is used to move these images into another study. For example, Series 2 that is included in Study 1, should actually be assigned to Study 2. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 Study 2 Series 1 The process in this instance is that the Series 2 is moved from Study 1 to Study 2. Study 1 Series 1 Study 1 Series 2 Study 2 Series 1 Study 2 Series 2 The final effect is that Study 1, contains Series 1 and Series 3, and Study 2 now contains its original series, plus the series that was previously assigned to Study 1. The following steps are used to move the series to another study. 1) Select the patient from the patient list that has the study containing the series to move, and click on the Select the study where the series is to be moved, and click on the 2) From the Utilities menu, select Move Series. 3) The Move The series shown into a different study dialog window opens, as shown here: BRIT QC User Manual 29

36 Chapter 6 Move Series to Another Study 4) Click on the study shown in the lower portion of this window to select the study where this series is to be placed. 5) Click on the 6) The Move Series to This Study dialog box opens, as shown here. This box indicates that the series will be deleted from the selected study and moved to the selected study for the patient. 7) If this move is correct, click on the button to move the series into the selected study. If this move is incorrect, click on the move. button to terminate the 8) The window now displays the old study in the left side, and the other study on the right side that now contains the series that has been moved. 9) From the Utilities menu, click on Accept/Reject Images, and the Mark Accept/Reject box displays, as shown here: 10) Verify that the selected series have been correctly split. 11) Click on the If some images are left unmarked, the study will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 12) Click on the button when ready. 13) The selected series are now included in the other study. 14) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: If everything is correct, click on the changes and archive the study. button to accept the If a series is incorrectly placed, click on the study. button to reject the changes and not archive the 15) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 30

37 Chapter 7 Move Study to Another Patient VII. Move Study to Another Patient Occasionally a study is performed that is assigned to the incorrect patient. When this happens the QC Workbench is used to assign the study to the correct patient. For example, Study 1 should actually be assigned to Patient B. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The procedure in this instance is that all series that were in Study 1, assigned to Patient A, are now reassigned to patient B. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 Now the Patient B contains all series in Study 1, previously assigned to Patient A. The following steps are used to assign the study to the correct patient. 1) Select the patient from the patient list that has the study that needs to be assigned to the correct patient, and click on the 2) From the Utilities menu, select Assign Study. BRIT QC User Manual 31

38 Chapter 7 Move Study to Another Patient 3) The Find a Patient dialog box opens, as shown here: 4) Enter the Accession Number, patient ID, Patient Name, Date, or Modality, and click on the 5) In the list at the lower part of the window, click on the patient ID, where the study is to be moved, and click on the 6) The Edit NEW Exam Info window opens, as shown here: The patient information on the left of this window identifies the destination of this study, while the patient information on the right identifies the patient where the study is currently located. It shows the new values for the study, as well as the new Accession Number. If any of the information needs to be changed for the study, it can be done at this time. Click on the button if all the information is correct. Click on the button of the incorrect patient was selected to terminate the process of reassigning the study. If the button is selected, a warning dialog box opens, as shown here to indicate that the entry will be restored to its original state and all changes will be erased. 7) A warning message appears asking if it is ok to reassign the study. It indicates that the archive will delete all of the images that it has for the old study and that the only images that will be reassigned to the new study are the ones that are on the local disk. It also indicates that if the archive is still receiving images for this study, or if only a part of the study is downloaded, that images could be lost without an easy way to get them back. BRIT QC User Manual 32

39 Chapter 7 Move Study to Another Patient It then asked if the user is sure that it is ok to reassign the study. Click on the button to continue and reassign the study to the selected patient. 8) If the study was successfully reassigned the correct patient information is now reassigned and shown. 9) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 10) Verify that the selected series have been appropriately moved to the correct patient. 11) Click on the If some images are left unmarked, the study will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 12) Click on the button when ready. 13) The selected study is now assigned to the other patient. 14) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: If everything is correct, click on the changes and archive the study. button to accept the If a series is incorrectly placed, click on the reject the changes and not archive the study. button to 15) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 33

40 Chapter 7 Move Study to Another Patient BRIT QC User Manual 34

41 Chapter 8 Move Series to Another Patient VIII. Move Series to Another Patient Occasionally a series is included in the incorrect patient. If a series that is part of a study is assigned to the wrong patient, that series must be split out into a separate study before it can be assigned to the correct patient. A series cannot be reassigned or moved to another patient without being split into a separate study in order to be reassigned. When this happens the QC Workbench is used to assign the study to the correct patient. For example, Series 2 that is included in Study 1 for Patient A, should actually be assigned to Patient B. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The process in this example is that the series is moved to a separate study, the study is reassigned to the correct patient. Study 1 Series 1 Study 1 Series 2 Study 1 Series 1 Study 1 Series 2 Now the Patient A contains its original Study 1, with Series 1 and Series 3, and Patient B contains its original Study 1 plus the series that was previously assigned to Patient A. BRIT QC User Manual 35

42 Chapter 8 Move Series to Another Patient The following shows all of the individual steps that are used to assign the series to the correct patient. 1) Select the patient from the patient list that has the study containing the series to be moved to the correct patient, and click on the 2) Select the patient where the study is to be moved, and click on the 3) A warning message appears indicating that two separate patients are being opened. Be extremely cautious here, make sure that the correct patient is selected for both series where they are for different patients! 4) Click on the button because the action is correct and the study is to be moved into the other patient opened. It splits the screen so that the first patient selected, which has the series to be moved, is shown on the left, and the second patient selected is shown on the right, which is where the series is to be moved. 5) Click on the series to be moved on the left side. 6) From the Utilities menu, select Move series to another patient. 7) The Move The series shown into a different study dialog window opens, as shown here: 8) Click on the study shown in the lower portion of this window to select the study where this series is to be placed. 9) Click on the 10) The Move Series to This Study dialog box opens, as shown below: This box indicates that the series will be deleted from the selected study and moved to the selected study for the patient. 11) If this move is correct, click on the button to move the series into the selected study. If this move is incorrect, click on the button to terminate the move. BRIT QC User Manual 36

43 Chapter 8 Move Series to Another Patient 12) The window now displays the old study in the left side, and the other study on the right side that now contains the series that has been moved. 13) From the Utilities menu, select Accept/Reject Images, and the Mark Accept/Reject box displays, as shown here: 14) Verify that the selected series have been split out to the correct study in the other patient. 15) Click on the If some images are left unmarked, the study will not be split, and a message box displays to indicate there are unmarked images. When this happens, the option is to return to the study and ensure all images are marked, or select to return to the study and finish it later. It will only be archived when all images are marked. 16) Click on the button when ready. 17) The selected series are now included in the other study for the other patient. 18) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, in the first patient, as shown here: If everything is correct, click on the the changes and archive the study. If a series is incorrectly placed, click on the reject the changes and not archive the study. button to accept button to 19) Another dialog box opens indicating the steps taken and verifying that the second study should be archived. It shows the number of series selected for Study #2, in the second patient, as shown here: If everything is correct, click on the the changes and archive the study. button to accept If a series is incorrectly placed, click on the reject the changes and not archive the study. button to 20) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer until all images are archived. BRIT QC User Manual 37

44 Chapter 8 Move Series to Another Patient BRIT QC User Manual 38

45 Chapter 9 Move Images to Another Patient IX. Move Images to Another Patient Occasionally a study is performed but the images are assigned to the wrong study. When this happens the QC Workbench is used to assign the images to the correct study. For example, there are seven images in series two for Patient A that should be assigned in Series 1 for Patient B. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The process in this example is that the series has to be split in the study, the study has to be split, the new study has to be reassigned to the correct patient, and if the images need to be part of an existing study in the new patient, the series needs to be moved to the correct study; however if the images need to be part of an existing series, the images need to be moved to that series. Study 1 Series 1 Study 1 Series 2 Study 1 Series 1 Study 1 Series 2 The final results is that Patient A contains its original Study 1, with Series 1 and Series 3 complete, as well as the 13 images that are correct in series 2. Patient B contains its original Study 1 with Series 1 and 2, plus the images that were previous assigned to Patient A s Study 1 Series 2 are now art of Patient B s Study 1 Series 1. BRIT QC User Manual 39

46 Chapter 9 Move Images to Another Patient There are several major steps that are required to move the images from one study to another study. It is not just a simple process of selecting the images and moving them. There are several steps, which include: 1) The images must be split into another series, if they are part of a series. 2) The series need to be assigned to a new study, (since only a study can be moved to a different patient). 3) The newly created study must be assigned to the correct patient. 4) If the images are to be part of a study that is currently exists for the patient, the images need to be moved to that correct study. 5) If the Images are to be part of a series that currently exist in that study, move the images to the correct series. The following steps are used to assign the images to the correct study. Step 1: Split the Images into a New Series The following steps are used to assign the images to the correct study. 1) Select the patient from the patient list that has the study containing the images to split, and click on the 2) Click on the series that contains the images that needs to be split. 3) Display a single series by pressing the S (for Split) key on the keyboard, and click on the 4) From the Utilities menu, and click on Split Series. To select individual images, click the left mouse button on each desired image that will be moved to the other series. Notice that when the image is selected a appears next to each selected image, and those with are not selected to be moved, as shown here: Get new image here BRIT QC User Manual 40

47 Chapter 9 Move Images to Another Patient 5) A Verify Details dialog box opens for the user to confirm the action, as shown here: This dialog box shows a summary of the total number of images in the series, the number of images that were not selected, and the number of images selected. It also shows the name of the old series and the exact same name of the new series. The New description should be changed so that duplicate series names are avoided. Change the name of the New Series, and click on the As the instructions indicate, a New series is created, and the marked images are moved from the Old sees to the New series. Selecting the activity. button terminates any 6) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 7) Verify that the selected series is correct, and that the image, or images, to be moved into this series is correct. Click on the button to accept the changes. 8) Click on the 9) The selected images should be split into a separate series. 10) Click on the button to close the selected study, and another dialog box opens indicating the steps taken and verifying that the study should be archived. Click on the study. button to accept the changes and archive the Click on the study. button to reject the changes and not archive the 11) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer BRIT QC User Manual 41

48 Chapter 9 Move Images to Another Patient Step 2: Move the New Series to a New Study 1) Select the patient from the patient list that has the study containing the series that need to be split into a different study, and click on the 2) From the Utilities menu, click on Split Study. 3) The SPLIT One Study Into Two Select series for each window opens, as shown here: 4) Click on the button, and click on the series that are to remain in the original study. Notice that as the series are selected the name is moved into the Original Study area. 5) Click on the button, and click on the series that are to be moved to a new study. Notice that as the series are selected the name is moved into the New Study area. 6) Click on the button to move the series as selected into the original or new studies. If any of the selections are incorrect, click on the button, and reselect the series for each. To terminate splitting series out of the study, click on the 7) Another dialog box opens asking if this is the correct action to take. It indicates the total number of series in the study, the number selected to remain in the original study, and the number to be moved to the new study. To confirm the action, click on the BRIT QC User Manual 42

49 Chapter 9 Move Images to Another Patient To cancel the action, click on the 8) The window now displays the old series in the left side, and the new series that is split out in the right side. 9) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 10) Verify that the selected series have been correctly split. 11) Click on the 12) Click on the button when ready. 13) The selected images should now be split into two separate studies. 14) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: If everything is correct, click on the the changes and archive the study. If a series is incorrectly placed, click on the reject the changes and not archive the study. button to accept button to 15) Another dialog box opens indicating the steps taken and verifying that the second study should be archived. It shows the number of series selected for Study #2, as shown here: If everything is correct, click on the changes and archive the study. button to accept the If a series is incorrectly placed, click on the reject the changes and not archive the study. button to 16) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer BRIT QC User Manual 43

50 Chapter 9 Move Images to Another Patient Step 3: Assign the New Study to the Correct Patient 1) Select the patient from the patient list that has the study that needs to be assigned to the correct patient, and click on the 2) From the Utilities menu, select Assign Study. 3) The Find a Patient dialog box opens, as shown here: 4) Enter the Accession Number, patient ID, Patient Name, Date, or Modality, and click on the 5) Click on the patient ID, where the study is to be moved, in the list below and click on the 6) The Edit NEW Exam Info window opens, as shown here: The patient information on the left of this window identifies the destination of this study, while the patient information on the right identifies the patient where the study is currently located. It shows the new values for the study, as well as the new Accession Number. If any of the information needs to be changed for the study, it can be done at this time. Click on the button if all the information is correct. Click on the button of the incorrect patient was selected to terminate the process of reassigning the study. If the button is selected, a warning dialog box opens, as shown here to indicate that the entry will be restored to its original state and all changes will be erased. BRIT QC User Manual 44

51 Chapter 9 Move Images to Another Patient 7) A warning message appears asking if it is ok to reassign the study. It indicates that the archive will delete all of the images that it has for the old study and that the only images that will be reassigned to the new study are the ones that are on the local disk. It also indicates that if the archive is still receiving images for this study, or if only a part of the study is downloaded, that images could be lost without an easy way to get them back. It then asked if the user is sure that it is ok to reassign the study. Click on the button to continue and reassign the study to the selected patient. 8) If the study was successfully reassigned the correct patient information is now reassigned and shown. 9) From the Utilities menu, select Assign/Reject Images and the Mark Accept/Reject box displays, as shown here: 10) Verify that the selected series have been correctly split. 11) Click on the 12) Click on the button when ready. 13) The selected study is now assigned to the other patient. 14) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: If everything is correct, click on the changes and archive the study. button to accept the If a series is incorrectly placed, click on the reject the changes and not archive the study. button to 15) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer BRIT QC User Manual 45

52 Chapter 9 Move Images to Another Patient Step 4: Move the Series to the Correct Study 1) Select the patient from the patient list that has the study containing the series to move, and click on the 2) Select the patient from the patient list that has the study where the series is to be moved, and click on the 3) From the Utilities menu, select Move Series. 4) The Move The series shown into a different study dialog window opens, as shown here: 5) Click on the study shown in the lower portion of this window to select the study where this series is to be placed. 6) Click on the 7) The Move Series to This Study dialog box opens, as shown here: This box indicates that the series will be deleted from the selected study and moved to the selected study for the patient. If this move is correct, click on the series into the selected study. button to move the If this move is incorrect, click on the the move. button to terminate 8) The window now displays complete study containing the new series that was moved. 9) From the Utilities menu, select Assign/Reject Images and the Mark Accept/Reject box displays, as shown here: 10) Verify that the selected series have been correctly split. 11) Click on the 12) Click on the button when ready. 13) The selected series are now included in the other study. BRIT QC User Manual 46

53 Chapter 9 Move Images to Another Patient 14) Click on the button to close the selected study. A dialog box opens indicating the steps taken and verifying that the first study should be archived. It shows the number of series selected for Study #1, as shown here: If everything is correct, click on the changes and archive the study. button to accept the If a series is incorrectly placed, click on the reject the changes and not archive the study. button to 15) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer Step 5: Move the Images to the Correct Series This last step is used if the images are supposed to be part of an existing series in the new patient. If the moved images are not supposed to be part of another series, stop here because the images are already in it s own series in the study. 1) Select the patient from the patient list that has the study containing the images to move, and click on the 2) Select the series that contains the images to move by clicking on the series. 3) Display a single series by pressing the S (for Split) key on the keyboard. 4) From the Utilities menu, select Move Images. 5) The following dialog box opens indicating the steps that need to be taken next. 12) To select individual images, click the left mouse button on each desired image that will be moved to the other series. Notice that when the image is selected a appears next to each selected image, and a appears next to images that are not selected to be moved. BRIT QC User Manual 47

54 Chapter 9 Move Images to Another Patient 6) A Mark to Move dialog box in the upper right corner of the window, select, to mark the series. 7) Select on this box, when all desired images are selected. 8) A Move the marked images into a different series dialog box opens to allow the user to select the series where the selected image(s) are to be moved. 9) Click on the series where the selected image(s) are to be moved. 10) Click on the 11) A Verify Details dialog box opens for the user to confirm the action, as shown here: This dialog box shows a summary of the total number of images in the series, the number of images that were not selected, and the number of images selected. It also shows the name of the old series and the exact same name of the new series. The New description should be changed so that duplicate series names are avoided. Change the name of the New Series, and click on the As the instructions indicate, a New series is created, and the marked images are moved from the Old sees to the New series. Selecting the activity. button, terminates any 12) From the Utilities menu, select Accept/Reject Images and the Mark Accept/Reject box displays, as shown here: 13) Verify that the selected series is correct, and that the image, or images, to be moved into this series is correct and click on the 14) Click on the button when ready. 15) The selected images should be moved into the correct series. BRIT QC User Manual 48

55 Chapter 9 Move Images to Another Patient 16) Click on the button to close the selected study, and another dialog box opens indicating the steps taken and verifying that the study should be archived. Click on the study. button to accept the changes and archive the Click on the the study. button to reject the changes and not archive 17) When the images are moved, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer BRIT QC User Manual 49

56 Chapter 9 Move Images to Another Patient BRIT QC User Manual 50

57 Chapter 10 Delete Series from a Study X. Delete Series from a Study Occasionally a study is performed in which the images need to be deleted. Follow these steps to delete the images from a series. For example, Series 2 needs to be removed from the study. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The process is that the images will be removed from Series 2 in the Study using the Accept/Reject Images function. Study 1 Series 1 Study 1 Series 3 The result is that the 20 images from Series 2 are deleted from the Study, and the Study only contains the original Series 1 and Series 3. The following steps are used to delete the images from the series. 1) Select the patient from the patient list that has the study containing the images to delete, and click on the 2) Select the series that contains the images to delete. 3) From the Utilities menu, select Accept/Reject Images 4) Click on each series that needs to be deleted. Notice that when the series is selected a red x appears next to each selected image. Also notice all other series which are selected are shown with green. 5) The Mark Accept/Reject box opens. BRIT QC User Manual 51

58 Chapter 10 Delete Series from a Study 6) If the selected series is to be deleted, click on the 7) A dialog box appears identifying the selections for the study and verifying that the correct steps are taken. Click on the Click on the button to delete the series. button to cancel the action. 8) When the images are removed, the selected series is closed, and the window returns to the Patient Select window. It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer BRIT QC User Manual 52

59 Chapter 11 Delete Entire Study XI. Delete Entire Study Occasionally a study is performed which need to be deleted. Follow these steps to delete the study. For example, the entire Study 1 needs to be removed from Patient A. Study 1 Series 1 Study 1 Series 2 Study 1 Series 3 The process is that study will be removed by utilizing the Accept/Reject Images function. The result Study 1 is completely removed from Patient A. The following steps are used to delete the entire study. 1) Select the patient from the patient list that has the study containing the images to delete, and click on the 2) Select the study to be deleted. 3) From the Utilities menu, select Accept/Reject Images. 4) The Mark Accept/Reject box opens. 5) If all series in the selected study are to be deleted, click on the Notice that all series in the study are selected and a red x appears next to each series. 6) A dialog box appears identifying the selections for the study and verifying that the correct steps are taken. Click on the button to delete the series. Click on the button to cancel the action. 7) When the series are removed, the selected series is closed, and the window returns to the Patient Select window. BRIT QC User Manual 53

60 Chapter 11 Delete Entire Study It may take a while for all the images in the study to be archived. It depends on the connection to the server, and the number of images in the study. The study will not be available on the RIS or the Viewer BRIT QC User Manual 54

61 Chapter 12 Delete Images from a Study XII. Delete Images from a Study Occasionally a study is performed in which the images need to be deleted. Follow these steps to delete the images from a series. The following steps are used to delete the entire study. 1) Select the patient from the patient list that has the study containing the series with the images to delete, and click on the 2) Select the series that contains the images to delete. 3) Display a single series by pressing the S (for Split) key on the keyboard, and click on the 4) From the Utilities menu, select Accept/Reject Images. 5) The Mark Accept/Reject box opens. 6) If there are just a few images to delete, click on the button, then click on an individual images until the red x appears, if only a few images are to be deleted. To select separate individual images, click the left mouse button on each desired image that will be deleted. Notice that when the image is selected a red x next to each selected image, as shown here: 7) A dialog box appears identifying the selections for the study and verifying that the correct steps are taken. Click on the Click on the button to delete the image. button to cancel the action. BRIT QC User Manual 55

Using IPACS Webserver:

Using IPACS Webserver: Using IPACS Webserver: Logging On: The IPACS Webserver can be accessed from any PC with internet connectivity. 1. Open Internet Explorer or your internet service provider. 2. Type the IPACS web address

More information

BRIT PACSView March 2010 Release 1.3 UM-BPV-001.3

BRIT PACSView March 2010 Release 1.3 UM-BPV-001.3 BRIT PACSView March 2010 Release 1.3 UM-BPV-001.3 Notices, Copyrights, and Revision Records Notices and Copyrights Notice This document is subject to change without notice and does not represent a commitment

More information

PACS Web. Training Documentation

PACS Web. Training Documentation PACS Web Training Documentation Table of Contents Section Page 1. LOGIN TO PACS WEB... 2 2. LOGOUT OF PACS WEB... 4 3. SEARCHING FOR A PATIENT... 5 4. PACS WEB REPORTS... 10 4.1. PATIENT INFO BUTTON...

More information

ClinicalConnect TM eunity TM Training Guide

ClinicalConnect TM eunity TM Training Guide ClinicalConnect TM eunity TM Training Guide October, 2013 Launch eunity TM from ClinicalConnect TM Search and select the patient whose record you wish to view. Navigate to the Radiology module in ClinicalConnect

More information

BRIT Roentgen Works System Administrator s Guide

BRIT Roentgen Works System Administrator s Guide BRIT Roentgen Works System Administrator s Guide June 2011 Release 1.2 UM-SMRW_0012, Notices, Copyrights, and Revision Records Notices and Copyrights Notice This document is subject to change without notice

More information

PACS ADMIN. Quick Reference Guide

PACS ADMIN. Quick Reference Guide Quick Reference Guide PACS ADMIN Creating Domain Users.......................................................... Adding NOVARAD Users......................................................... Adding Console

More information

Instructions for using Borg and Ide CONNECT. Referring Provider Portal. Version 3.5.

Instructions for using Borg and Ide CONNECT. Referring Provider Portal. Version 3.5. Instructions for using Borg and Ide CONNECT Referring Provider Portal www.borgideconnect.com Version 3.5 Topic Table of Name Contents Description Getting Started...1 Home Page and Finding Patient Exams...2

More information

PACS Scan Mobile. User Help. Version: Written by: Product Knowledge, R&D Date: September 2016 LX-DOC-PSM2.0.1-UH-EN-REVB

PACS Scan Mobile. User Help. Version: Written by: Product Knowledge, R&D Date: September 2016 LX-DOC-PSM2.0.1-UH-EN-REVB PACS Scan Mobile User Help Version: 2.0.1 Written by: Product Knowledge, R&D Date: September 2016 2016 Lexmark. All rights reserved. Lexmark is a trademark of Lexmark International Inc., registered in

More information

9 Working With DICOM. Configuring the DICOM Option

9 Working With DICOM. Configuring the DICOM Option 9 Working With DICOM DICOM (Digital Imaging and Communications in Medicine) is a format created by NEMA (National Electrical Manufacturers Association) to aid in the distribution and viewing of medical

More information

2. Type your use name and password in their respective fields.

2. Type your use name and password in their respective fields. Logging on to the Portal To log on to the application 1. Open a Web browser and in the address bar type https://mrp.oiarad.com/amikportal.web/ 2. Type your use name and password in their respective fields.

More information

Searching for Images in v10

Searching for Images in v10 Searching for Images in v10 Following are the steps to search for images in Docfinity version 10. Searching for Images: Log into Docfinity on www.controller.psu.edu/docfinity Open Searching Workspace in

More information

PACS QUICK REFERENCE GUIDE

PACS QUICK REFERENCE GUIDE Version: 7.6.2.22 QUICK REFERENCE ADMIN/RADIOLOGIST PACS QUICK REFERENCE GUIDE Critical Findings The purpose of this document is to instruct Radiologists how to mark images with any critical finding or

More information

Index. 1. Introduction Installation and Getting started MediGate

Index. 1. Introduction Installation and Getting started MediGate Index Rex2 Premium Software Part 1. Introduction... 3 2. Installation and Getting started... 4 3. MediGate 1.0... 9 3.1 Outline... 9 3.2 Toolbar... 11 3.3 Viewer... 25 3.4 Local Database... 28 3.5 DICOM

More information

Contents. User's Guide

Contents. User's Guide Contents i User's Guide ii Contents No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without prior written permission from

More information

VXVUE USER GUIDE. For Technical Support Questions please call 888.4VETRAY or Page1

VXVUE USER GUIDE. For Technical Support Questions please call 888.4VETRAY or Page1 The following describes VXvue software as it pertains to end user applications. Detailed instructions are included in the ViewWorks Setup Guide and ViewWorks Control Setup Operation provided with each

More information

ClinicalExpress Operator s Guide. version 6.1 for general radiography and mammography

ClinicalExpress Operator s Guide. version 6.1 for general radiography and mammography ClinicalExpress Operator s Guide version 6.1 for general radiography and mammography Copyright by VIDAR Systems Corporation. All rights reserved. No part of this publication may be reproduced, stored in

More information

DataMaster for Windows

DataMaster for Windows DataMaster for Windows Version 3.0 April 2004 Mid America Computer Corp. 111 Admiral Drive Blair, NE 68008-0700 (402) 426-6222 Copyright 2003-2004 Mid America Computer Corp. All rights reserved. Table

More information

E-Report. User Manual

E-Report. User Manual E-Report User Manual 2011 All rights reserved. No parts of this work may be reproduced in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information

More information

FaxFinder Fax Servers

FaxFinder Fax Servers FaxFinder Fax Servers Models: FF130 FF230 FF430 FF830 Client User Guide FaxFinder Client User Guide Fax Client Software for FaxFinder Series PN S000460B, Version B Copyright This publication may not be

More information

Enrollment Operator Guide. Avigilon Access Control Manager System Version

Enrollment Operator Guide. Avigilon Access Control Manager System Version Enrollment Operator Guide Avigilon Access Control Manager System Version 5.12.0 2018, Avigilon Corporation. All rights reserved. AVIGILON, the AVIGILON logo, ACCESS CONTROL MANAGER, ACM, and ACM VERIFY

More information

User s Quick Reference. EMC ApplicationXtender Web Access 5.40 P/N REV A01

User s Quick Reference. EMC ApplicationXtender Web Access 5.40 P/N REV A01 EMC ApplicationXtender Web Access 5.40 User s Quick Reference P/N 300-005-669 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994 2007 EMC

More information

14 July Ver CRView V3 User Guide. 1 P a g e

14 July Ver CRView V3 User Guide. 1 P a g e Ver. 080707 CRView V3 User Guide 1 P a g e Contents Copyright notice... 3 Trademarks... 3 System requirements... 4 Required hardware... 4 Recommended hardware... 4 Installing CRView... 5 Installing from

More information

Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ. Tel: +44 (0) Fax: +44 (0) mailmarkup.com funasset.

Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ. Tel: +44 (0) Fax: +44 (0) mailmarkup.com funasset. Funasset Limited Foundry House Foundry Road Taunton Somerset TA1 1JJ Tel: +44 (0)1823 365864 Fax: +44 (0)1823 277266 mailmarkup.com funasset.com Copyright 2012 Funasset Limited. All rights reserved. Products

More information

JobSite OnLine User s Guide Table of Contents

JobSite OnLine User s Guide Table of Contents JobSite OnLine User s Guide Table of Contents For the Beginner: 2 Preparing and Logging In to Run JobSite OnLine...2 How Drawings and Specs are Organized - Ease of Use...3 Searching for Files or Containers...4

More information

GreenFolders User Manual

GreenFolders User Manual GreenFolders User Manual Welcome! Welcome to GreenFolders the Electronic Records Management Solution. GreenFolders allows you to store and retrieve files with many easy-to-use features for working with

More information

efilm Workstation Quick Reference

efilm Workstation Quick Reference efilm Workstation Quick Reference Toolbar Features Customizing the Toolbar Toolbar Properties NOTE: Some tools have function key shortcuts, which can be adjusted. You can alter the mouse button selection

More information

Approving a Requisition

Approving a Requisition Approving a Requisition If you are both the Requester and the Approver you will not need to follow this process. The requisition that you save and approve will bypass the Worklist and move on to Budget

More information

Palm Reader Handbook

Palm Reader Handbook Palm Reader Handbook Copyright 2000-2002 Palm, Inc. All rights reserved. Graffiti, HotSync, the Palm logo, and Palm OS are registered trademarks of Palm, Inc. The HotSync logo and Palm are trademarks of

More information

Océ Engineering Exec. Electronic Job Ticket

Océ Engineering Exec. Electronic Job Ticket Océ Engineering Exec Electronic Job Ticket Océ-Technologies B.V. Copyright 2004, Océ-Technologies B.V. Venlo, The Netherlands All rights reserved. No part of this work may be reproduced, copied, adapted,

More information

Opal RAD User Manual

Opal RAD User Manual Opal RAD Mini Manual Table of Contents Basic Workflow of Opal RAD... 3 Introduction... 4 Logging On... 5 The Study List screen... 6 Searching and Sorting Your Studies... 7 Installing and Updating the Image

More information

Single Menus No other menus will follow necessitating additional user choices

Single Menus No other menus will follow necessitating additional user choices 57 UNIT-III STRUCTURES OF MENUS Single Menus No other menus will follow necessitating additional user choices Sequential Linear Menus Simultaneous Menus 58 Hierarchical Menus When many relationships exist

More information

Gear View QC. User Help. Version Written by: Product Documentation and R&D Date: August 2015 LX-DOC-GVQC UH-EN-REVA

Gear View QC. User Help. Version Written by: Product Documentation and R&D Date: August 2015 LX-DOC-GVQC UH-EN-REVA Gear View QC User Help Version 2.2.0 Written by: Product Documentation and R&D Date: August 2015 2015 Lexmark International Technology, S.A. All rights reserved. No part of this publication may be reproduced,

More information

TABLE OF CONTENTS. 1 Installation Instructions 1.1 Prior to Install 1.2 Download the software 1.3 Obtaining the PIKO-PACS by Opal License

TABLE OF CONTENTS. 1 Installation Instructions 1.1 Prior to Install 1.2 Download the software 1.3 Obtaining the PIKO-PACS by Opal License 1 TABLE OF CONTENTS 1 Installation Instructions 1.1 Prior to Install 1.2 Download the software 1.3 Obtaining the PIKO-PACS by Opal License 2 Introduction to PikoPACS by Opal 2.1 What is PikoPACS by Opal?

More information

ECR Vault User Guide. An ImageDirector product from Milner Technologies, Inc. ECR Vault Version 8.0

ECR Vault User Guide. An ImageDirector product from Milner Technologies, Inc. ECR Vault Version 8.0 ECR Vault User Guide An ImageDirector product from Milner Technologies, Inc. ECR Vault Version 8.0 COPYRIGHT Copyright 1995-2015 Milner Technologies, Inc. This manual and the software described in it are

More information

VXvue User Manual (For Human Use)

VXvue User Manual (For Human Use) VXvue User Manual (For Human Use) Page 2 of 90 Revision History Version Date Description 1.0 2012-03-20 Initial Release Page 3 of 90 Contents Safety and Regulatory... 8 Safety Notice... 8 1. Introduction...

More information

XnView Image Viewer. a ZOOMERS guide

XnView Image Viewer. a ZOOMERS guide XnView Image Viewer a ZOOMERS guide Introduction...2 Browser Mode... 5 Image View Mode...14 Printing... 22 Image Editing...26 Configuration... 34 Note that this guide is for XnView version 1.8. The current

More information

AllFusion Harvest Change Manager Help Guide

AllFusion Harvest Change Manager Help Guide AllFusion Harvest Change Manager Help Guide Help and Reference Document Developed for: Ministry of Community Services Ministry of Tourism, Sport and the Arts Version 6.00 March 29, 2007 Revision Notes

More information

KMnet Viewer. User Guide

KMnet Viewer. User Guide KMnet Viewer User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We cannot be

More information

Unicon TM CL Series Software REFERENCE MANUAL

Unicon TM CL Series Software REFERENCE MANUAL Unicon TM CL Series Software REFERENCE MANUAL Trademarks The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. Unicon Windows, Windows 2000,

More information

Help us make this document better smarttech.com/docfeedback/ SMART Ink 3.1 USER S GUIDE FOR WINDOWS OPERATING SYSTEMS

Help us make this document better smarttech.com/docfeedback/ SMART Ink 3.1 USER S GUIDE FOR WINDOWS OPERATING SYSTEMS Help us make this document better smarttech.com/docfeedback/170830 SMART Ink 3.1 USER S GUIDE F WINDOWS OPERATING SYSTEMS Trademark notice SMART Ink, SMART Notebook, SMART Meeting Pro, Pen ID, smarttech,

More information

JAZZ HARMONY User Manual

JAZZ HARMONY User Manual JAZZ HARMONY User Manual Copyright 2017 Imaging. All rights reserved. This manual and the software described herein are protected by copyright laws and international copyright treaties, as well as other

More information

If your webpage looks like the screen below please go to your browsers tools section and clear out all history.

If your webpage looks like the screen below please go to your browsers tools section and clear out all history. Quick Notes: Please use internet explorer 9 or higher to have an optimal experience New URL to access the Nav Web Digital experience is http://navweb.mom365.com/login.aspx o You will be redirected to the

More information

Voxar 3D ColonMetrix. Reference Guide

Voxar 3D ColonMetrix. Reference Guide Voxar 3D ColonMetrix Reference Guide The software described in this document is furnished under a license, and may be used or copied only according to the terms of such license. Toshiba means, Toshiba

More information

How to update or change your banking information in isolved

How to update or change your banking information in isolved How to update or change your banking information in isolved 1. Login to isolved through the Purdue intranet site or from the NASDA web page. 2. Choose the Direct Deposit Updates tab under Employee Self

More information

CARESTREAM Vita/Vita LE/Vita XE CR System Software / V3.2 User Guide

CARESTREAM Vita/Vita LE/Vita XE CR System Software / V3.2 User Guide CARESTREAM Vita/Vita LE/Vita XE CR System Software / V3.2 User Guide 2012-07-12 9G8916 Version 1.0 Use of the Guide CARESTREAM CR Systems are designed to meet international safety and performance standards.

More information

User's Guide. Voice Messaging and Fax Software. FaxTalk Communicator SETM

User's Guide. Voice Messaging and Fax Software. FaxTalk Communicator SETM User's Guide Voice Messaging and Fax Software FaxTalk Communicator SETM FaxTalk Communicator SE for Windows Version 4.7 Telephone Consumer Protection Act of 1991 "It shall be unlawful for any person within

More information

MillinPro+ USER GUIDE. A Complete Web-Based Platform for Managing Medical Bills and Insurance Claims

MillinPro+ USER GUIDE. A Complete Web-Based Platform for Managing Medical Bills and Insurance Claims MillinPro+ A Complete Web-Based Platform for Managing Medical Bills and Insurance Claims MILLIN ASSOCIATES, LLC USER GUIDE 2010-2012 Copyrights Reserved Millin Associates, LLC Document Change History Version

More information

With Online Fax, you can send and receive faxes, view queued/archived faxes, add contacts from the following North American locations:

With Online Fax, you can send and receive faxes, view queued/archived faxes, add contacts from the following North American locations: AT&T Online Fax allows you to send and receive faxes in email format, access your faxes from virtually any device with internet without the need for a dedicated fax line. AT&T Intellectual Property. All

More information

NETWORK PRINT MONITOR User Guide

NETWORK PRINT MONITOR User Guide NETWORK PRINT MONITOR User Guide Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change for improvement without notice. We

More information

To access the images that accompany a Radiology result from Memorial Health System select the document in Chart Viewer and click on View.

To access the images that accompany a Radiology result from Memorial Health System select the document in Chart Viewer and click on View. ImageLink To access the images that accompany a Radiology result from Memorial Health System select the document in Chart Viewer and click on View. On the upper right side of the Order Viewer select the

More information

Oracle General Navigation Overview

Oracle General Navigation Overview Oracle 11.5.9 General Navigation Overview 1 Logging On to Oracle Applications You may access Oracle, by logging onto the ATC Applications Login System Status page located at www.atc.caltech.edu/support/index.php

More information

Diagnostic Viewer User Manual

Diagnostic Viewer User Manual Diagnostic Viewer User Manual NovaPACS Diagnostic Viewer User Manual March 28, 2013 Version 8.0.7 Copyright 2013 Novarad Corporation. All rights reserved. This publication may not be copied, reproduced,

More information

TEL:

TEL: 1 This document is intended to be used as user s manual of VetView. For more details on this user s manual or VetView, contact the following information. TEL: +82-70-8672-6220 E-Mail: dr_service@rayence.com

More information

User Guide 701P Wide Format Solution Wide Format Scan Service

User Guide 701P Wide Format Solution Wide Format Scan Service User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.

More information

User Manual. DICOM workstation software. Doc No. : TM-706-KR Rev Nov 2014 Part No. : CR-FPM EN

User Manual. DICOM workstation software. Doc No. : TM-706-KR Rev Nov 2014 Part No. : CR-FPM EN DICOM workstation software Doc No. : TM-706-KR Rev 1.2.1 Nov 2014 Part No. : CR-FPM-04-003-EN 3DISC, FireCR, Quantor and the 3D Cube are trademarks of 3D Imaging & Simulations Corp, South Korea, and its

More information

2. Type your use name and password in their respective fields.

2. Type your use name and password in their respective fields. Logging on to the Portal To log on to the application 1. Open a Web browser and in the address bar type https://mrp.oiarad.com/nhiportal.web/account/logon 2. Type your use name and password in their respective

More information

Layout and display. STILOG IST, all rights reserved

Layout and display. STILOG IST, all rights reserved 2 Table of Contents I. Main Window... 1 1. DEFINITION... 1 2. LIST OF WINDOW ELEMENTS... 1 Quick Access Bar... 1 Menu Bar... 1 Windows... 2 Status bar... 2 Pop-up menu... 4 II. Menu Bar... 5 1. DEFINITION...

More information

FactoryLink 7. Version 7.0. Client Builder Reference Manual

FactoryLink 7. Version 7.0. Client Builder Reference Manual FactoryLink 7 Version 7.0 Client Builder Reference Manual Copyright 2000 United States Data Corporation. All rights reserved. NOTICE: The information contained in this document (and other media provided

More information

IMAGE VIEWER. Following is the explanation of different settings and features: Page. First Page

IMAGE VIEWER. Following is the explanation of different settings and features: Page. First Page IMAGE VIEWER All scanned and or imported documents can be seen in Image Viewer. SequelMed image viewer is a powerful viewer where you can manipulate scanned documents. It has basic features starting from

More information

Secure Guard Central Management System

Secure Guard Central Management System Speco Technologies, Inc. Secure Guard Central Management System Usage Information Contents 1 Overview... 7 2 Installation... 7 2.1 System Requirements... 7 2.2 System Installation... 7 2.3 Command Line

More information

RG3 Meter Company. AMR Software Solutions. Operation and Procedure Manual. for. Field Meter Reading.

RG3 Meter Company. AMR Software Solutions. Operation and Procedure Manual. for. Field Meter Reading. RG3 Meter Company AMR Software Solutions Operation and Procedure Manual for Field Meter Reading www.rg3meter.com TABLE OF CONTENTS I Import Data from Billing System to AMRSS Server Software Pg 3 II Mobile

More information

DICOM * /30* /30 MADE IN GERMANY

DICOM * /30* /30 MADE IN GERMANY DICOM 9000-608-108/30 *9000-608-108/30* MADE IN GERMANY Contents Important Information 1. Notes.................................. 4 Installation and Usage 2. Installation............................ 5

More information

Quick Reference Guide

Quick Reference Guide Key functions Quick Reference Guide Philips isite Enterprise Version 3.6 Enhance mouse cursor mode Function Wheel mouse 2-button mouse Adjust WW/WL Left click and drag Left click and drag Scroll/Cine Wheel

More information

DICOM Conformance Statement

DICOM Conformance Statement DICOM Conformance Statement McKesson Cardiology Release 13.2.1 June 2016 Doc ID DCM-10018 Doc Revision 1.0 Produced in Cork, Ireland Revision History Revision Revision Date Summary of Changes Rev. 1.0

More information

TOF-Watch SX Monitor

TOF-Watch SX Monitor TOF-Watch SX Monitor User manual Version 1.2 Organon (Ireland) Ltd. Drynam Road Swords Co. Dublin Ireland Contents General information... 3 Getting started... 3 File Window... 7 File Menu... 10 File Open

More information

Wholesale Lockbox User Guide

Wholesale Lockbox User Guide Wholesale Lockbox User Guide August 2017 Copyright 2017 City National Bank City National Bank Member FDIC For Client Use Only Table of Contents Introduction... 3 Getting Started... 4 System Requirements...

More information

8.0.6 New Features Guide Auto Window/Level Adjustments

8.0.6 New Features Guide Auto Window/Level Adjustments 8.0.6 New Features Guide Improvements to the feature allow users to quickly and easily set for images. These adjustments will be automatically and consistently applied to similar images. Window/Level Adjustments

More information

Teleradiology Management System. User Guide Technologist Supplement

Teleradiology Management System. User Guide Technologist Supplement Teleradiology Management System User Guide Technologist Supplement User Guide Technologist Supplement Table of Contents 1. Life Cycle of an Exam...3 2. Login...3 3. Worklist...4 4. Tech Workflow...6 I.

More information

Virtual Desktop (Windows 7 VM) User Guide

Virtual Desktop (Windows 7 VM) User Guide Virtual Desktop (Windows 7 VM) User Guide Welcome to using your new Virtual Desktop. This technology will offer mobility, enhanced security, and extreme versatility via Citrix technologies and Windows

More information

ATEK Intelligence Platform

ATEK Intelligence Platform ATEK Intelligence Platform for Instruction Guide www.tankscan.com AIP (ATEK Intelligence Platform)... 3 Log In... 3 AIP Navigation... 4 a. Menu Tabs... 4 1. Views Menu... 4 2. Grids Menu... 4 3. Actions

More information

XnView 1.9. a ZOOMERS guide. Introduction...2 Browser Mode... 5 Image View Mode...15 Printing Image Editing...28 Configuration...

XnView 1.9. a ZOOMERS guide. Introduction...2 Browser Mode... 5 Image View Mode...15 Printing Image Editing...28 Configuration... XnView 1.9 a ZOOMERS guide Introduction...2 Browser Mode... 5 Image View Mode...15 Printing... 22 Image Editing...28 Configuration... 36 Written by Chorlton Workshop for hsbp Introduction This is a guide

More information

Document Management System GUI. v6.0 User Guide

Document Management System GUI. v6.0 User Guide Document Management System GUI v6.0 User Guide Copyright Copyright HelpSystems, LLC. All rights reserved. www.helpsystems.com US: +1 952-933-0609 Outside the U.S.: +44 (0) 870 120 3148 IBM, AS/400, OS/400,

More information

OnBase Quick Reference Guide

OnBase Quick Reference Guide Support: Team M teamm@onbase.com 440.788.6605 Prepared by: Hyland Software, Inc. 28500 Clemens Road Westlake, Ohio 44145 Ph: (440) 788-5000 Fax: (440) 788-5100 www.hyland.com DISCLAIMER Copyright Hyland

More information

NJUNS Users Guide.

NJUNS Users Guide. NJUNS Users Guide www.njuns.com The National Joint Utilities Notification system, NJUNS, is a national organization of member utilities formed for the purpose of improving the coordination of joint ventures.

More information

Instructions for Display of Imaging Studies Using Stentor isite

Instructions for Display of Imaging Studies Using Stentor isite Instructions for Display of Imaging Studies Using Stentor isite Open http://isite.rad.tju.edu in Internet Explorer Log-In: Enter your user name (case Sensitive) and password (case sensitive) and press

More information

emix Implementation Steps

emix Implementation Steps emix Implementation Steps Copyright 2009-2013 DR Systems, Inc. 1 Contents About emix 3 Benefits... 3 How emix works... 3 1 Installing the emix Gateway 4 Station requirements... 4 Additional station requirements...

More information

Quick & Simple Imaging. User Guide

Quick & Simple Imaging. User Guide Quick & Simple Imaging User Guide The Quick & Simple Imaging software package provides the user with a quick and simple way to search and find their documents, then view, print, add notes, or even e- mail

More information

OrderSmart. April 21, Passport Health Communications, Inc. All Rights Reserved

OrderSmart. April 21, Passport Health Communications, Inc. All Rights Reserved OrderSmart P hysician Office userguide April 21, 2014 2014 Passport Health Communications, Inc. All Rights Reserved Table of Contents 1.0 General Information... 7 1.1 Product Overview... 7 1.2 Authorized

More information

RIS RECEPTION. Quick Reference Guide

RIS RECEPTION. Quick Reference Guide Quick Reference Guide RIS RECEPTION Adding and Editing Physician Information........................................ Next Avaiable Time Slot.......................................................... Editing

More information

interactive lockbox User Guide

interactive lockbox User Guide interactive lockbox User Guide 1 TABLE OF CONTENTS INTRODUCTION... 3 Calendar & Buttons... 3 GETTING STARTED.... 5 Dashboard.... 7 INTERACTIVE LOCKBOX BASICS... 9 ILB Menu.... 9 Batch List... 9 Transaction

More information

2. Click New in the upper left corner of the standard toolbar (along the top) to open a new message box.

2. Click New in the upper left corner of the standard toolbar (along the top) to open a new message box. Mail Exercise 1: Sending a Message 1. Click Mail in the Navigation Pane. 2. Click New in the upper left corner of the standard toolbar (along the top) to open a new message box. 3. Enter utstr3@mailbox.sc.edu

More information

Online Submission Tool: Packet Management

Online Submission Tool: Packet Management Online Submission Tool: Packet Management OLS: Packet Management December 2012 Disclaimer The materials in this reference guide are for demonstration purposes only. The forms are subject to change at any

More information

Easy Windows Working with Disks, Folders, - and Files

Easy Windows Working with Disks, Folders, - and Files Easy Windows 98-3 - Working with Disks, Folders, - and Files Page 1 of 11 Easy Windows 98-3 - Working with Disks, Folders, - and Files Task 1: Opening Folders Folders contain files, programs, or other

More information

Software Quick Manual

Software Quick Manual XX177-22-00 Virtual Matrix Display Controller Quick Manual Vicon Industries Inc. does not warrant that the functions contained in this equipment will meet your requirements or that the operation will be

More information

Physicians Quick Guide. Software Version 5.3

Physicians Quick Guide. Software Version 5.3 Physicians Quick Guide Software Version 5.3 1 DOC-0033746-A 9/20/2016 Locating a Study in Worklist or Folder 1. Log on to Synapse using the method prescribed by your PACS administrator 2. If prompted,

More information

LOCKBOX EXCEPTION MODULE USER GUIDE March 2018

LOCKBOX EXCEPTION MODULE USER GUIDE March 2018 LOCKBOX EXCEPTION MODULE USER GUIDE March 2018 2018 First Tennessee Bank National Association operating as First Tennessee Bank and Capital Bank. Member FDIC. TABLE OF CONTENTS Introduction 3 Startup 4

More information

TeamSpot 2. Introducing TeamSpot. TeamSpot 2.5 (2/24/2006)

TeamSpot 2. Introducing TeamSpot. TeamSpot 2.5 (2/24/2006) TeamSpot 2 Introducing TeamSpot TeamSpot 2.5 (2/24/2006) Table of Contents AN INTRODUCTION TO TEAMSPOT...3 INSTALLING AND CONNECTING (WINDOWS XP/2000)... 4 INSTALLING AND CONNECTING (MACINTOSH OSX 2.8

More information

Practice Labs User Guide

Practice Labs User Guide Practice Labs User Guide This page is intentionally blank Contents Introduction... 3 Overview... 3 Accessing Practice Labs... 3 The Practice Labs Interface... 4 Minimum Browser Requirements... 5 The Content

More information

Table of Contents RURO, Inc. All Rights Reserved

Table of Contents RURO, Inc. All Rights Reserved Table of Contents ABOUT THIS GUIDE... 7 Purpose of this Guide...7 ACCESSING THE SYSTEM AS A CLIENT PORTAL USER... 7 Navigating the Client Portal...7 Creating and Submitting a New Requisition...8 Accepting

More information

User Guide For Universal Devices Administrative Console (ISY)

User Guide For Universal Devices Administrative Console (ISY) User Guide For Universal Devices Administrative Console (ISY) - 1 - Table of Contents 1. PURPOSE 6 2. THEORY OF OPERATION 6 3. INSTALLATION 7 4. CONFIGURATION 8 4.1 Prerequisites 8 4.1.1 Host Computer

More information

Quick Reference. EMC ApplicationXtender Media Distribution Viewer 5.40 P/N REV A01

Quick Reference. EMC ApplicationXtender Media Distribution Viewer 5.40 P/N REV A01 EMC ApplicationXtender Media Distribution Viewer 5.40 Quick Reference P/N 300-005-645 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1994-2007

More information

OnBase Quick Reference Guide

OnBase Quick Reference Guide OnBase Quick Reference Guide Unity Client Retrieval For OnBase 10.0 Support: Team M teamm@onbase.com 440.788.6605 Prepared by: Hyland Software, Inc. 28500 Clemens Road Westlake, Ohio 44145 Ph: (440) 788-5000

More information

RemotEye Viewer, version 9. User Manual

RemotEye Viewer, version 9. User Manual RemotEye Viewer, version 9 User Manual Table of Contents 1 ABBREVIATIONS... 6 2 INDICATIONS FOR USE... 6 3 BEFORE YOU BEGIN... 6 3.1 MINIMUM HARDWARE REQUIREMENTS... 7 3.2 SUPPORTED OPERATING SYSTEMS...

More information

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1

IMAGE STUDIO LITE. Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 IMAGE STUDIO LITE Tutorial Guide Featuring Image Studio Analysis Software Version 3.1 Notice The information contained in this document is subject to change without notice. LI-COR MAKES NO WARRANTY OF

More information

1 Introduction to AutoCAD

1 Introduction to AutoCAD 1 Introduction to AutoCAD The term CAD (Computer Aided Design) applies to a wide range of programs that allow th user to created drawings, plans, and designs electronically. AutoCAD is one such program

More information

Astra Schedule User Guide Scheduler

Astra Schedule User Guide Scheduler Astra Schedule User Guide 7.5.12 Scheduler 1 P a g e ASTRA SCHEDULE USER GUIDE 7.5.12... 1 LOGGING INTO ASTRA SCHEDULE... 3 LOGIN CREDENTIALS... 3 WORKING WITH CALENDARS... 4 CHOOSING A CALENDAR AND FILTER...

More information

Aerial iexchange Users Guide

Aerial iexchange Users Guide Aerial iexchange Users Guide 2014.1 How to Run the Util\\\ \user Disclaimer How to reach us Copyright Information contained in this document is subject to change without notice and does not present a commitment

More information

C CURE HDVR Integration User Guide. Version 1.93 REVISION A0

C CURE HDVR Integration User Guide. Version 1.93 REVISION A0 C CURE 9000 Version 1.93 HDVR Integration User Guide REVISION A0 6 Technology Park Drive Westford, MA 01886-3140 http://www.swhouse.com Fax: 978-577-4392 Phone: 978-577-4000 Copyright and Trademarks C

More information

Quick KVM 1.1. User s Guide. ClearCube Technology, Inc.

Quick KVM 1.1. User s Guide. ClearCube Technology, Inc. Quick KVM 1.1 User s Guide ClearCube Technology, Inc. Copyright 2005, ClearCube Technology, Inc. All rights reserved. Under copyright laws, this publication may not be reproduced or transmitted in any

More information

For the Beginner: c) Click the settings tab to set screen resolution d) Set resolution with slider bar.

For the Beginner: c) Click the settings tab to set screen resolution d) Set resolution with slider bar. For the Beginner: Preparing and Logging In to Run JobSite OnLine 1) Jobsite works best with a screen resolution of at least 800 x 600 preferably 1024 x 768. To set this, follow the instructions below.

More information