Cedex Analyzer Operator s Manual

Size: px
Start display at page:

Download "Cedex Analyzer Operator s Manual"

Transcription

1 Cedex Analyzer Operator s Manual Software Version June 2016 For use in quality control/manufacturing processes only.

2 Cedex Analyzer Addendum 3 to Operator s Guide, Version 3.0 Software Version June 2016 For use in quality control/manufacturing process only.

3 2 Cedex Analyzer Addendum 3 to Operator s Guide, Version 3.0

4 Information Regarding the Cedex Analyzer Operator s Manual, Software Version Information Regarding the Cedex Analyzer Operator s Manual, Software Version Please read the following update information for the Cedex Analyzer Operator s Manual, Software Version This addendum includes: c Information about Cedex Software version c Updating from Cedex Software version or to Cedex Software version c Update of Section B, Chapter 4.6 of the Cedex Analyzer Operator s Guide, Set the Cedex Server to Autostart. If you have any further questions regarding this matter, please do not hesitate to contact Roche Technical Service at your convenience. To call, write, fax, or us, visit the Custom Biotech homepage, Software Version

5 Information About Cedex Software Version Information About Cedex Software Version All the functions and features described in the Cedex Analyzer Operator s Manual, Software Version 2.3.2, also apply to Cedex Software version For more information about the functions and features of Cedex Software version and 2.3.1, please refer to the Cedex Analyzer Operator s Manual, Software Version Cedex Analyzer Addendum 3 to Operator s Guide, Version 3.0

6 Updating from Cedex Software Version to Cedex Software Version Updating from Cedex Software Version to Cedex Software Version The procedure described in this chapter applies only for updating from Cedex Software version or to version c For details about installing or updating to Cedex Software version 2.3.2, please refer to Section B, Updating to Cedex Software or Installing the Cedex Software 2.3.2, in the Cedex Analyzer Operator s Guide, Software Version Before starting an update of your current Cedex Software to Cedex Software version 2.3.4, ensure that: c You have Cedex Software version or installed on your system, and you have the required software package for updating to Cedex Software version Consult with your local Roche Technical Service in case of questions. c You have administrator access to the Control Unit. c A storage device with enough disk space is available for a backup of the current installation. Check the size of the folder containing all Cedex Software 2 files, including the database file (usually the directory C:\Cedex2). The size of the backup will be approximately the size of this folder. c Enough time is scheduled for a backup of the current installation (approximately one hour for backup to a fast external hard drive per 10 GB disk space used in the Cedex2 directory, including the database file). Before performing any form of installation or update procedure, the actual (effective) values for the FlowFactor and ChamberHeight must be saved and stored for future reference. These values may need to be adjusted in the System Options after the installation or update procedure is complete. The value for FlowFactor is located in the System Options menu under the General tab. The value for the ChamberHeight is located in the System Options menu under the Hardware tab. See System Options and User Preferences in the Appendix for more information. Before updating the software, ensure that you have created a backup of the Cedex Software database in a remote, secure storage device that is not part of the Control Unit. Also, ensure that you fully read and understand the following instructions before proceeding with the update of the Cedex Software. If an error occurs or if you do something incorrectly, this could result in data loss and/or could prevent the Cedex Software from operating. If the Cedex Software version or is not yet installed on your Control Unit, please refer to Section B, Updating to Cedex Software or Installing the Cedex Software 2.3.2, in the Cedex Analyzer Operator s Guide for information updating to Cedex Software Software Version

7 Updating from Cedex Software Version to Cedex Software Version To update from Cedex Software version or to Cedex Software version 2.3.4, do the following: 1 Place the folder containing the Cedex Software version update on the Control Unit, and double-click on the Cedex Setup exe program. 2 Click on Install. Figure 1 If a window appears asking for administrator confirmation, click Yes and continue with the installation. 3 Click on Next. Figure 2 4 Put a checkmark in the box I accept the terms in the License Agreement and click on Next. Figure 3 ccc 6 Cedex Analyzer Addendum 3 to Operator s Guide, Version 3.0

8 Updating from Cedex Software Version to Cedex Software Version Click on Next to install the Cedex Software files into the recommended folder (C:\Cedex2). Figure 4 6 Click on Install to initiate the installation. Figure 5 7 The installation will begin. Figure 6 8 When the following dialog box appears, click on Finish. Figure 7 ccc Software Version

9 Updating from Cedex Software Version to Cedex Software Version The Setup Successful dialog box will appear if the installation was completed successfully. Confirm with OK. Figure 8 Cedex Software is now installed. 8 Cedex Analyzer Addendum 3 to Operator s Guide, Version 3.0

10 Section B Chapter 4.6: Set the Cedex Server to Autostart Update of Section B, Chapter 4.6 of the Cedex Analyzer Operator s Guide Cedex Analyzer Operator s Guide, sw 2.3.2, page 49 c Updated procedure for setting the Cedex Server to autostart. Section B Chapter 4.6: Set the Cedex Server to Autostart The Cedex Server must be started before the Cedex Client can be started. If desired, the Cedex Server can be configured to start automatically when the Control Unit is turned on. If not, continue with the next section. To configure the Cedex Server to autostart, do the following: 1 Open Windows Explorer by left-clicking on the Windows Start button, and then expand on All Programs. 2 Scroll down to the Startup folder, right click on the Startup folder and select the option Open All Users. 3 Copy the shortcut Cedex Server from the desktop to the Startup folder. ccc Software Version

11 Section B Chapter 4.6: Set the Cedex Server to Autostart 4 Open the Properties dialog box for the Cedex Server by right-clicking on the icon and selecting Properties. Select the Shortcut tab and change the property for Run to Minimized via the drop-down menu. Click on Apply, and then OK. Continue with Section B, Chapter 4.7 to start the Cedex Software for the first time after update or installation of the Cedex Software. 10 Cedex Analyzer Addendum 3 to Operator s Guide, Version 3.0

12

13 For use in quality control/manufacturing process only. CEDEX is a trademark of Roche. All other product names and trademarks are the property of their respective owners. Published by Roche Diagnostics GmbH Sandhofer Strasse Mannheim Germany 2016 Roche Diagnostics. All rights reserved

14 Cedex Analyzer Addendum 2 to Operator s Guide, Version 3.0 Software Version February 2016 For use in quality control/manufacturing process only.

15 2 Cedex Analyzer Addendum 2 to Operator s Guide, Version 3.0

16 Information Regarding the Cedex Analyzer Operator s Manual, Software Version Information Regarding the Cedex Analyzer Operator s Manual, Software Version Please read the following update information for the Cedex Analyzer Operator s Manual, Software Version This addendum includes: c Information about Cedex Software version c Updating from Cedex Software version to Cedex Software version c Information regarding functions that can be assigned to User Roles c Information about the Use blacklist feature If you have any further questions regarding this matter, please do not hesitate to contact Roche Technical Service at your convenience. To call, write, fax, or us, visit the Custom Biotech homepage, Software Version

17 Information About Cedex Software Version Information About Cedex Software Version All the functions and features described in the Cedex Analyzer Operator s Manual, Software Version 2.3.2, also apply to Cedex Software version For more information about the functions and features of Cedex Software version and 2.3.1, please refer to the Cedex Analyzer Operator s Manual, Software Version Cedex Analyzer Addendum 2 to Operator s Guide, Version 3.0

18 Updating from Cedex Software Version to Cedex Software Version Updating from Cedex Software Version to Cedex Software Version The procedure described in this chapter applies only for updating from Cedex Software version to version c For details about installing or updating to Cedex Software version 2.3.2, please refer to Section B, Updating to Cedex Software or Installing the Cedex Software 2.3.2, in the Cedex Analyzer Operator s Guide, Software Version Before starting an update of your current Cedex Software to Cedex Software version 2.3.3, ensure that: c You have Cedex Software version installed on your system, and you have the required software package for updating to Cedex Software version Consult with your local Roche Technical Service in case of questions. c You have administrator access to the Control Unit. c A storage device with enough disk space is available for a backup of the current installation. Check the size of the folder containing all Cedex Software 2 files, including the database file (usually the directory C:\Cedex2). The size of the backup will be approximately the size of this folder. c Enough time is scheduled for a backup of the current installation (approximately one hour for backup to a fast external hard drive per 10 GB disk space used in the Cedex2 directory, including the database file). Before performing any form of installation or update procedure, the actual (effective) values for the FlowFactor and ChamberHeight must be saved and stored for future reference. These values may need to be adjusted in the System Options after the installation or update procedure is complete. The value for FlowFactor is located in the System Options menu under the General tab. The value for the ChamberHeight is located in the System Options menu under the Hardware tab. See System Options and User Preferences in the Appendix for more information. Before updating the software, ensure that you have created a backup of the Cedex Software database in a remote, secure storage device that is not part of the Control Unit. Also, ensure that you fully read and understand the following instructions before proceeding with the update of the Cedex Software. If an error occurs or if you do something incorrectly, this could result in data loss and/or could prevent the Cedex Software from operating. If the Cedex Software version is not yet installed on your Control Unit, please refer to Section B, Updating to Cedex Software or Installing the Cedex Software 2.3.2, in the Cedex Analyzer Operator s Guide for information updating to Cedex Software Software Version

19 Updating from Cedex Software Version to Cedex Software Version To update from Cedex Software version to Cedex Software version 2.3.3, do the following: 1 Place the folder containing the Cedex Software version update on the Control Unit, and double-click on the Cedex Setup exe program. 2 Click on Install. Figure 1 If a window appears asking for administrator confirmation, click Yes and continue with the installation. 3 Click on Next. Figure 2 4 Put a checkmark in the box I accept the terms in the License Agreement and click on Next. Figure 3 ccc 6 Cedex Analyzer Addendum 2 to Operator s Guide, Version 3.0

20 Updating from Cedex Software Version to Cedex Software Version Click on Next to install the Cedex Software files into the recommended folder (C:\Cedex2). Figure 4 6 Click on Install to initiate the installation. Figure 5 7 The installation will begin. Figure 6 8 When the following dialog box appears, click on Finish. Figure 7 ccc Software Version

21 Updating from Cedex Software Version to Cedex Software Version The Setup Successful dialog box will appear if the installation was completed successfully. Confirm with OK. Figure 8 Cedex Software is now installed. 8 Cedex Analyzer Addendum 2 to Operator s Guide, Version 3.0

22 Section D Chapter 7: Administrator Functions Cedex Analyzer Operator s Guide, sw 2.3.2, page 120 Additional information regarding functions that can be assigned to User Roles Section D Chapter 7: Administrator Functions The table below provides a list of the functions that can be added to user roles, as well the access rights that are granted by the selected function. Function that can be added to a User Role Adjustment Archiving Audit Trail Cell Type Cleaning Data Exchange Diagnosis Hardware management Liquid container configuration Lock / Unlock Logging and Tracing Measurement Batch Measurement CTC Measurement Run Measurement View Operational Data Access rights granted by the function Access to the Adjustment and Alignment Verification dialog box; perform an Automatic Adjustment. Access to the Archive and Restore dialog boxes to allow for archiving measurements and restoring archived measurements. Access to the Audit Trail dialog box. Access to the Live Operator dialog box and the Cell Type List dialog box; define, modify, or delete cell types. A user who does not have this function can still reprocess measurements. Access to the Cleaning dialog box; perform cleaning functions. Access to the Import to DB and Export to DB dialog boxes to allow for import or export of complete measurement packages for data exchange with other instruments. Access to the Diagnosis dialog box for running various diagnoses of the system. Access and perform functions in the Hardware Management dialog box hardware management functions: HW Shutdown, Prime, LM Shutdown, HW Startup. Access the Reagent Container Configuration dialog box and set the minimum and maximum liquid levels for reagent and waste containers. Access to the Change System Status dialog box to allow for locking or unlocking the system (e.g., in case of an SST failure). Access Trace and Logging dialog box and modify settings concerning the trace and logs. Trace and Logging functionalities should only be activated at the request of an authorized service technician. Access the Multi Run dialog box to run batch measurements. Access the Cultivation Time Chart dialog box to create and view Cultivation Time Charts. Access the Measurement dialog box to run a single measurement. Access the Measurement List dialog box to view a list of measurements in the database and view results and histograms from past measurements. Access and reset operational data in the Operational Data dialog box. Print out information about operational data. Software Version

23 Section D Chapter 7: Administrator Functions Function that can be added to a User Role Reagent Kit Status Report Templates Reports Schedule SST Edit SST Run Syringe Maintenance System Options User Preferences User Rights Access rights granted by the function Access and reset the level of reagents in the Reagent Kit Status dialog box. Access the Report Templates dialog box in order to edit report templates. Access various options for printing reports. Access to the Schedule dialog box; define cleaning functions to be automatically performed at a certain intervals. Create and edit SST checkpoints. Run SST checkpoints and view SST trending charts. Access the Syringe Maintenance dialog box in order to exchange the syringe. Access to the System Options dialog box. Access the User Preferences dialog box to change the preferences of the logged-in user. Access the User Rights Management dialog box to define, create and modify users and their respective roles and rights. Five standard user roles are pre-installed by the Software. All of the roles are suggested roles that could be used for setting up specific distribution of access rights: c Administrator: By default, the Administrator only has the function User rights assigned to the role. c Superuser: By default, the Superuser has all functions assigned to the role with the exception of User rights. c Production staff: By default, no functions are assigned to this role. c Research staff: By default, no functions are assigned to this role. c Support: By default, no functions are assigned to this role. 10 Cedex Analyzer Addendum 2 to Operator s Guide, Version 3.0

24 Section D Chapter 7: Administrator Functions Cedex Analyzer Operator s Guide, sw 2.3.2, page 121 Information about the Use blacklist feature Section D Chapter 7: Administrator Functions Please note that the Use blacklist feature is not an active feature and, therefore, cannot be used. The option UseBlacklist appears in the System Options dialog box with a default value set to 1, but it is not active. Software Version

25 For use in quality control/manufacturing process only. CEDEX is a trademark of Roche. All other product names and trademarks are the property of their respective owners. Published by Roche Diagnostics GmbH Sandhofer Straße Mannheim Germany 2016 Roche Diagnostics. All rights reserved

26 Cedex Analyzer Addendum 1 to Operator s Guide, Version 3.0 Software Version April 2014 For use in quality control/manufacturing processes only.

27 Section B: System Description Chapter 6: Securing Access Rights Information Regarding the Cedex Analyzer Operator s Guide Please read the following information, which updates information given in the Cedex Analyzer Operator s Guide Dear valued user of the Cedex Analyzer This addendum includes: c Additional information about password format requirements for the Windows 7 Operating System when changing passwords or creating new users. c Additional information about saving reports in electronic file format. c Updated information about the procedure for removal, reinstallation or replacement of the syringe. If you have any further questions regarding this matter, please do not hesitate to contact Roche Technical Service at your convenience. To call, write, fax, or us, visit the Custom Biotech home page, Section B: System Description Chapter 6: Securing Access Rights Please note that when creating a new user with a corresponding password at the Windows Operating System level, or changing the password for an already created user, the following rules must be observed: c Passwords must be at least 12 characters. c Passwords must not contain the user s account name or parts of the user s full name that exceed two consecutive characters. c Passwords must contain characters from three of the following four categories: c English uppercase characters (A through Z). c English lowercase characters (a through z). c Base 10 digits (0 through 9). c Non-alphabetic characters (for example,!, $, #, %). To change the password settings and allow for other options, do the following 1 Log on to the Control Unit as the Win-Admin user. 2 Click the Start menu, type secpol.msc, without the quotes, in the Search area and press <Enter>. The Local Security Policy dialog box opens. 3 Using the tree structure on the left-hand side of the Local Security Policy dialog box, navigate to Security Settings -> Account Policies -> Password Policy. 4 Double-click on the settings in the right-hand pane to change the password policy as desired. 2 Cedex Analyzer Operator s Guide Addendum 1 to Operator s Guide, Version 3.0

28 Section D: Software Chapter : Printing Reports Section D: Software Chapter : Printing Reports Please note the following when using the Print Report function for printing out reports: The Preview dialog box of a report provides the option for saving the preview as a.pdf file type, using the Save icon at the top of the Preview dialog box. Choosing this option may result in a PDF report with an incorrect layout. To save the report in file format with a correct layout, Roche recommends the following: 1 In the preview window of a report, click the Save as icon at the top of the preview page and choose the file format option XPS File. 2 The generated.xps file can be saved, printed out, and viewed on other compatible computers with a Windows Operating System. Section E: Maintenance and Care Chapter 5: Syringe Maintenance Follow the syringe maintenance procedure described on pages to remove, reinstall or replace the syringe of the Cedex System. After removal, reinstallation or replacement of the syringe, a calibration check of the Cedex System must also be performed. Use Cedex Density Reference Standard Beads to check the calibration and confirm that the FlowFactor is correct. If necessary, adjust the FlowFactor. To perform the Cedex System calibration check and FlowFactor adjustment, follow the instructions described in the online Instructions for Use for the Density Reference Standard Beads, available for download via the Custom Biotech home page: Ordering Information Product Pack Size Cat. No. Density Reference Standard Beads 1 10 ml Batch A Density Reference Standard Beads 1 10 ml Batch B

29 For use in quality control/manufacturing processes only. CEDEX and INNOVATIS are trademarks of Roche. All other product names and trademarks are the property of their respective owners. Published by Roche Diagnostics GmbH Sandhofer Straße Mannheim Germany 2014 Roche Diagnostics. All rights reserved

30 Performing a Single Measurement (April 2014) Moving parts of the Multi Sampler may cause hand injuries. The Multi Sampler needle may cause injuries during operation. Never use the Cedex Analyzer without the protective cover in place for the Multi Sampler. Start the Cedex Analyzer and Software 1 Switch on the Cedex Analyzer. 2 Switch on the monitor and PC. Perform a Measurement 1 Click on the MEASURE button in the Cedex Control Center to open the Measurement dialog box. 2 In the Measurement dialog box, enter a clearly defined Reactor ID to describe the sample (e.g. the name of the cell culture or bioreactor name) in the Reactor ID area. You may either choose a Reactor ID from the drop down list or enter a new Reactor ID. 3 Enter a clearly defined Sample ID in the Sample ID area. Multiple Sample IDs can be listed under one Reactor ID. The Sample ID can be freely defined. 3 Log in to the Windows Operating System. 4 Start the Cedex Software 2.3 by double clicking on the Cedex Client icon located on the desktop (the Cedex Server should already be automatically started. It must be first started before the Cedex Software 2.3 can be started). The Log In dialog box of the Cedex Software 2.3 will open. 5 Enter the username in the User Name field and password in the Password field and press <Return>. The Cedex Control Center appears after a successful login. Perform a Hardware Startup and Prime 1 Click on the HWM button in the Cedex Control Center to open the Hardware Management dialog box. If the Hardware Management has not been started, the current status field will have the message Not started. 2 Click on HW Startup if the Hardware Management has not been started. The Hardware Management will start and the current status field will have the message HW started and LM not primed. 3 Ensure that a clean, empty Cedex Sample Cup is correctly positioned on the Multi Sample Tray in the DefaultCup position (usually sample cup position 1) or on the single sample port and click on Prime in the Hardware Management dialog box. 1 / 2 4 Choose the appropriate dilution factor from the Dilution drop-down list. For undiluted samples, enter a dilution factor of 1:1. When a dilution of 1:2 is prepared, then 1 part cell suspension has been added to 1 part dilution medium. A dilution of 1:3 means that 1 part cell suspension has been added to 2 parts dilution medium. The dilution factor will be automatically taken into account in the calculation of the results. 5 Select the sample volume of 1000 µl in the Volume drop-down menu. 6 Enter comments (if desired) in the Comment box. 7 Select the sample port type in the Sample Port drop-down list: c Auto Sampler: for systems with a Multi Sampler. c Single: for systems with a single sample port. 8 Enter the cup position for the sample in the Cup Position dialog box if there is a Multi Sampler. 9 Select the cell type that optimally recognizes your cells from the Cell Type drop-down list: c Factory-installed cell type is Std. Size (V5.00) If a new cell type has been created, it can also be selected from the same Cell Type drop-down list. ccc For use in quality control/manufacturing processes only. Cedex Software Quick Guide

31 Performing a Single Measurement (April 2014) Logging Out and/or Shutting Down 10 Select the desired precision level in the Precision drop-down list: c Minimum: 10 images are used for the analysis. c Normal: 20 images are used for the analysis. c Superior: 30 images are used for the analysis. 11 Prepare the sample. The Cedex Analyzer requires a volume of 1000 µl +/- 10%. Any greater variation in sample volume will lead to inaccurate results. 1 Open the Hardware Management dialog box (HWM button on the Cedex Control Center). 2 Click on LM Shutdown to shut down the Liquid Management system. 3 To log out of the Cedex Control Center, click on Logout under the System menu or on the LOGOUT button in the Cedex Control Center. The Cedex Software will be ended and the login dialog box will reappear Attach the Cedex Sample Cup containing the sample to the sample port, or place it in the appropriate sample cup position on the Multi Sample Tray. The sample cup is correctly attached to the single sample port when it is in an upright position directly beneath it and the capillary tube almost reaches the base of the sample cup. 13 Click on the START MEASUREMENT button to start the measurement. 14 When the measurement is finished, the top section of the Result Data area in the Measurement dialog box will display the overall results from the measurement. The bottom section displays, in succession, the results from each image taken. CEDEX is a trademark of Roche. All other product names and trademarks are the property of their respective owners. 2 / 2 4 Alternatively, shut down the Cedex Software by selecting Exit under the System menu or by clicking on to close the Cedex Control Center dialog box. 5 The security query, Do you really want to exit the Cedex Control Center?, will appear. Click on Yes to shut down the program. 6 The sample cup from the last measurement should remain attached to the sample port during the entire shutdown procedure and should only be removed when a new sample cup has been attached for the next measurement. In the case of a Multi Sampler, a sample cup should always be left in the DefaultCup position on the Multi Sample Tray at all times (see Quick Guide Working with the Multi Sampler ). Published by: Roche Diagnostics GmbH Sandhofer Strasse Mannheim For use in quality control/manufacturing processes only. Cedex Software Quick Guide

32 Working with the Multi Sampler (April 2014) Moving parts of the Multi Sampler may cause hand injuries. The Multi Sampler needle may cause injuries during operation. Never use the Cedex Analyzer without the protective cover in place for the Multi Sampler. The Multi Sampler DefaultCup The position of the Cedex Sample Cup used for Prime, LM Shutdown, calibration and cleaning routines is called the DefaultCup position. An empty Cedex Sample Cup must be manually placed in the position set for the DefaultCup before running LM Shutdown, focus adjustment, Prime and all cleaning routines. This Cedex Sample Cup does not differ from the usual sample cups. The standard (default) position for the DefaultCup is position 1 of the Multi Sample Tray. Using the Multi Sample Tray To insert the tray, gently push the tray into the notch until the automatic tray rope starts pulling it in. To eject the tray, gently push on the tray. The tray will be automatically ejected. The tray can only be ejected when the system is idle. It cannot be ejected if the system is moving or the needle is down in a cup. 1 / 2 Carrying out a Measurement with the Multi Sampler 1 Click on the MULTI RUN button on the Cedex Control Center to open the Multi Run dialog box. 2 Fill 1000 µl +/- 10% of the samples to be measured into individual Cedex Sample Cups (maximum 20) and place them in the Multi Sample Tray according to the desired sequence. Insert the tray into the Multi Sampler. 3 Click anywhere in the row of the Multi Run preparation area that corresponds to the location of a cup containing a sample. The row will be converted to edit mode, and the sample and process parameters for the measurement can be defined. 4 Enter the sample data and parameter information as described in the section Carry out a Measurement in the Quick Guide Performing a Single Measurement. 5 Repeat steps 3 4 for the remaining samples to be measured. 6 Activate the status of each sample row by double clicking in the Status field of the row to be activated. The row appears pale blue, and further modifications of sample information is impossible. Return to the Edit status by double clicking on the Status area of the sample row to allow for further changes, if desired. 7 Alternatively, activate or deactivate all samples simultaneously by double clicking on the word Status in the column heading at the top of the Multi Run preparation area. Confirm the safety query with YES to accept the modification. 8 After some or all rows have been activated, click on the START button on the right-hand side of the Multi Run dialog box to start the analysis of the activated measurements. For use in quality control/manufacturing processes only. Cedex Software Quick Guide

33 Working with the Multi Sampler (April 2014) Modifying Data Entry, Changing Samples Viewing results via the Multi Run Result List Information about the operation and process parameters for samples that have not yet been analyzed can be modified during the run as follows: 1 Double-click on the Status field of the measurement to be modified. The status field will indicate that the sample is in edit mode. 2 Make desired changes to the measurement. 3 Double-click on the Status field to re-activate the measurement (status: active or scheduled). Adding Measurements to the List while Measurements are Running Sample rows in which data has not yet been entered can be filled out at any time while the Multi Run is running. In addition, sample rows containing finished measurements (status: done) can be cleared and prepared for a new measurement by double-clicking in the Status field of the row with the finished measurement. Sample data for a measurement cannot be modified after that measurement has begun. CEDEX is a trademark of Roche. All other product names and trademarks are the property of their respective owners. 2 / 2 At the bottom of the Multi Run dialog box, the Analyzed Measurements field displays the list of results for measurements previously carried out. Measurements are listed in order of process time, from the newest measurements at the top of the list to the oldest measurements at the bottom. All measurements carried out using the Multi Run dialog box will be displayed in this field unless the Clear Resultlist button has been pressed, which will clear all measurement results from the list. In addition, measurements displayed in this field can be restricted to only the measurements carried out by the user logged into the system (mine), measurements that have not yet been printed out (unprinted), and/or measurements carried out on that particular day (today). Other results, such as Average Diameter, can be added for display in the result list via the User Preferences (see Adjusting Result Display in the Measurement List and Multi Run dialog boxes in the Cedex Operator s Guide). Double-click on a measurement to view all results. If the result list has been cleared, previously carried out measurements can still be viewed, printed out and exported via the Measurement List dialog box (see Using the Measurement List in the Cedex Operator s Guide). Published by: Roche Diagnostics GmbH Sandhofer Strasse Mannheim Germany For use in quality control/manufacturing processes only. Cedex Software Quick Guide

34 Preparing and Maintaining the Analyzer (April 2014) Moving parts of the Multi Sampler may cause hand injuries. The Multi Sampler needle may cause injuries during operation. Never use the Cedex Analyzer without the protective cover in place for the Multi Sampler. Changing the Reagent Kit Refilling Individual Containers Proceed as follows to install or change the Reagent Kit: 1 If the Liquid Management system has been primed, click on the HWM button in the Cedex Control Center to open the Hardware Management dialog box. 2 Attach a clean Cedex Sample Cup to the sample port or place a sample cup in the DefaultCup position on the Multi Sample Tray, and click on LM Shutdown in the Hardware Management dialog box to shut down the Liquid Management. 3 Remove the old Reagent Kit containers from the tray and dispose of the containers if necessary. 4 Place the new Reagent Kit containers in the appropriate positions on the Reagent Tray. 5 Insert the capillaries into the containers via the holes in the lids. Ensure that the capillary tubes are not bent and almost reach the base of the containers. 6 Select the Reagent Kit Status option in the Functions menu of the Cedex Control Center to open the Reagent Kit Status dialog box. 7 Click on the REPLACE ALL CONTAINERS button in right-hand corner of the Reagent Kit Status dialog box to confirm the changing of the Reagent Kit. The Reagent Control display at the bottom right-hand corner of the Cedex Control Center will turn from red to green and indicate the number of runs left. 8 Attach a clean Cedex Sample Cup to the sample port or place a sample cup in the DefaultCup position on the Multi Sample Tray, and perform a Prime via the Hardware Management dialog box (HWM button on the Cedex Control Center). 1 / 2 In order to ensure the optimal functioning of the analyzer, the reagent containers must be thoroughly cleaned before refilling with fresh reagents. Reagents can be refilled, or in the case of waste emptied, individually. 1 Shut down the liquid management via the Hardware Management dialog box as in step 1 2 of Changing the Reagent Kit, above. 2 Remove the reagent containers to be refilled, empty them and rinse thoroughly with distilled water. Empty waste container, if necessary. 3 Add fresh reagents to the appropriate reagent bottles and place them back in their correct positions on the Reagent Tray. 4 Insert the capillaries into the containers via the holes in the lids. Ensure that the capillary tubes are not bent and almost reach the base of the containers. 5 Select the Reagent Kit Status option in the Functions menu of the Cedex Control Center to open the Reagent Kit Status dialog box. 6 Confirm the refilling of each reagent container individually by clicking on the respective SET FULL button (or EMPTY button in the case of waste) in the Reagent Kit Status dialog box. For use in quality control/manufacturing processes only. Cedex Software Quick Guide

35 Preparing and Maintaining the Analyzer (April 2014) Cleaning the System Interrupting a Measurement Manual cleaning routines can be carried out in the Cleaning dialog box. To open the Cleaning dialog box, click on the CLEAN button in the Shortcuts area of the Cedex Control Center or select Cleaning routines in the Functions menu. The following cleaning routines can be run manually: c Fast Clean: Entire Liquid Management system is rinsed with detergent, and distilled water for approx. 60 seconds. c Standard Clean: Entire Liquid Management system is rinsed with disinfectant, detergent, and distilled water for approx. 90 seconds. c Intensive Clean: Entire Liquid Management system is rinsed with disinfectant, detergent, and distilled water for approx. 20 minutes. c Chamber Clean 1: Flow chamber is rinsed with water at high pressure for approx. 10 seconds. c Chamber Clean 2: Flow chamber is rinsed with water and detergent at high pressure for approx. 30 seconds. CEDEX is a trademark of Roche. All other product names and trademarks are the property of their respective owners. 2 / 2 An orange EMERGENCY STOP button is located on the left-hand side of the Measurement dialog box and can be activated during the measuring procedure to interrupt the analysis process. If the EMERGENCY STOP is selected, an error message will appear asking, Do you want to cancel the process?. c c Click on YES to stop and abort the process immediately. If YES is selected, the EMERGENCY STOP button will change to read Unlock Queue. The system must be unlocked by clicking on this button before more measurements can be run. Click on NO to put the process on hold until another action is chosen. If NO is selected, the EMERGENCY STOP button will change to read Resume. Click on this button to resume the measurement process. Only use the EMERGENCY STOP button in an emergency. Actual measurement data may be lost. Published by: Roche Diagnostics GmbH Sandhofer Strasse Mannheim Germany For use in quality control/manufacturing processes only. Cedex Software Quick Guide

36 Cedex Analyzer Operator s Guide Software Version April 2014 For use in quality control/manufacturing processes only.

37

38 Table of Contents Prologue 9 I. Document Information Revision History Edition Notice Copyright Trademarks... 9 II. III. IV. Contact Addresses...10 Warranty...10 Intended Use...10 V. Software Disclaimer...10 VI. VII. VIII. IX. Software License Agreement...11 Preamble...14 Contents of this Operator s Guide...14 Conventions Used in this Guide...15 X. Warnings and Precautions...16 XI. Disposal of the Analyzer...18 A Overview 19 1 Description of the Cedex System The Measurement Procedure The Trypan Blue Exclusion Method Data Analysis Technical Specifications of the Analyzer

39 Table of Contents B System Description 25 1 Installing the Cedex System Choosing a Suitable Location Connecting Hardware Components Connecting or Disconnecting the Device Updating to Cedex Software or Installing the Cedex Software Overview Overview: Updating from Cedex Software 1.x to Cedex Software Overview: Updating from Cedex Software 2.1.x or 2.2.x to Cedex Software Overview: Updating from Cedex Software 2.3.x to Cedex Software Create a Backup of the Cedex Software Version 2.3.x Database Update or Recover Windows Operating System to Windows Install the Frame Grabber and Multi I/O Drivers Install the Frame Grabber and Multi I/O Drivers Check the Driver Installation Install Cedex Software Version Initiate the Software Installation Install a New Database During Software Installation Update an Existing Database During Software Installation Set the Cedex Server to Autostart Start Cedex Software for the First Time After Installation Starting the Cedex System Securing Access Rights Access Control at the Windows Operating System Level Access Control at the Cedex System Software Level Cedex Analyzer Operator s Guide

40 Table of Contents C Operation 57 1 Overview of the Cedex Control Center Menu Bar System Menu Measurement Menu Functions Menu Reports Menu Master Data Menu Setup Menu Help Menu Shortcuts Area Tracking of Status of Events Carried Out by the Analyzer Preparing the Analyzer for Measurements Switching On Logging In at the Computer Operating System Level Starting the Cedex Software Performing a HW Startup and Prime Preparing the Reagent Kit Installing or Changing the Reagent Kit Refilling Containers Individually Checking the Analyzer Carrying Out a Single Measurement Opening the Measurement Dialog Box and Specifying the Operating Mode and Sample Data Defining the Measurement and Analysis (Process) Parameters Preparing the Sample and Attaching it to the Multi Sample Tray or Sample Port Starting the Measurement End of Measurement Interrupting a Measurement Working with the Multi Sampler The Multi Sampler DefaultCup Preparing the Measurement Using the Multi Sample Tray Ejecting the Multi Sample Tray Performing a Prime Carrying Out Measurements with the Multi Sampler The Multi Run Data Entry Dialog Box Preparing for Multiple Measurements in the Multi Run Dialog Box Activating Sample Rows and Starting the Measurement Adding Measurements to the List While Measurements are Running Modifying Data Entry, Changing Samples Non-Linear Measurements in a Sample Series LOAD DATA FROM XML Interrupting a Multi Run Disruption of Measurements Results The Multi Run Result List Switching Off the Cedex Analyzer Carrying Out an LM Shutdown and HW Shutdown Logging Out Shutting Down the Cedex Control Center

41 Table of Contents D Software 83 1 Using the Measurement Results Dialog Box Result Data Area Sample Parameters and Processing Parameters Areas Image Area Viewing Individual Cell Images Viewing a Cell Image Using the Image View Dialog Box Excluding Images from the Evaluation Process/Including Excluded Images Using the Measurement List Viewing Existing Analysis Results Searching for Measurements Editing Existing Analysis Results/Data Sets The Reprocess Button Effective Data Sets Graphical Display of the Analysis Results Enlarging the Histograms Aggregate Histogram Cell Diameter Histogram Defining Diameter Intervals in the Diameter Histogram Object Diameter Histogram Compactness Histogram Measurement Statistics Histogram Cultivation Time Chart Creating a CTC View The View Area The Series of Measurements Belonging to Selected View Area Adding Measurements to a View Editing Measurements in a View Viewing List of Measurements in a Series Deleting Views and Series Exporting a View Creating a Cultivation Time Chart The Data Selection Area Fitting to the Lowest Common Value Measurement Series Offset Variable Axis Calibration The Exponential Regression Button Printing Out a Cultivation Time Chart General Functions of the System Data Management Printing Reports Export to File Data Exchange Export Import Viewing and Evaluating the Audit Trail File User Preferences Adjusting Result Display in the Measurement List and Multi Run Dialog Boxes Specifying Default Measurement Parameters Specifying Other Default Parameters Specifying the Workarea for the Analysis Data Changing Own Password Cedex Analyzer Operator s Guide

42 Table of Contents D Software continued 7 Administrator Functions Administration of User Accounts Creating User Accounts Assigning Access Rights Creating User Groups Editing and Deleting User Accounts Creating and Editing User Roles Password Management Specifying Password Characteristics Assigning New Passwords Assigning Work Areas The System Options Automatically Start the Hardware Management Modifying the Standard Setting for the Multi Sampler DefaultCup Turning Off Automatic Incrementation of Sample Cup Position Error Level Displayed to Users Liquid Container Configuration Disabling the Reagent Control Default Settings Adjustment of the Image Analysis Using the Live Operator Description of the Cell Type List and Live Operator The Cell Type List Dialog Box Creating a New Cell Type Editing an Existing Cell Type Viewing an Existing Cell Type Deleting an Existing Cell Type Working with the Live Operator Description of the Individual Operator Parameters Archiving Data Archive Restore Deleting Archived Data Reducing the Size of the Database After Archiving Data Backing up the Database Basic Backup of the Database Incremental Backup of the Database

43 Table of Contents E Maintenance and Care Cleaning and Maintenance Checklist Scheduling Automatic Cleaning Routines Daily and Manual Maintenance and Cleaning Routines Checking the Reagent Containers When Manually Refilling Cleaning Routines Carried Out by the Liquid Management Cleaning Options The Hardware Management Dialog Box Carrying Out a Cleaning Routine Interrupting/Terminating a Cleaning Routine Live View of the Flow Chamber Automatic Adjustment Syringe Maintenance Removing the Syringe Assembling and Installing the Syringe Maintenance of the Syringe Guide and Spindle Maintenance of the Flow chamber, Microscope Optic, 8-Way Valve and the remaining Hardware Components Operational Data The System Suitability Test (SST) Creating SST Checkpoints Creating SST Checkpoints with and without Measurements Running a Water Blank Setting up the SSTFailureReaction in the System Options Menu Performing an SST Performing an SST with Measurements Performing an SST without Measurements Tracking Trends in SST Results Over Time Tracking Trends in SST Checkpoints with Measurements Tracking SST Checkpoints without Measurements Locking Unlocking the System F Troubleshooting Diagnosis of the Cedex Analyzer Trace and Logging The System Audit Trail File G Appendix System Options and User Preferences Cedex Analyzer Operator s Guide

44 Document Information Prologue I. Document Information 1 Revision History Version Software Version Revision Date Changes 1.0 V 2.2 May 2011 First Edition 2.0 V 2.3 August 2013 Complete revision due to Software update. 3.0 V April 2014 Updated Intended Use Update of Section B, installation, based on new SW version Updated information about Windows Operating System to Win7 for SW version Edition Notice The Cedex Analyzer Operator s Guide is for users of the Cedex Analyzer (running Software Version 2.3.2). 3 Copyright Copyright 2014, Roche Diagnostics GmbH, all rights reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Roche Diagnostics GmbH. Questions or comments regarding the contents of this Operator s Guide can be directed to your local Roche Diagnostics representative. Every effort has been made to ensure that all the information contained in the Cedex Analyzer Operator s Guide is correct at the time of printing. However, Roche Diagnostics GmbH reserves the right to make any changes necessary without notice as part of ongoing product development. 4 Trademarks CEDEX and INNOVATIS are trademarks of Roche. All other product names and trademarks are the property of their respective owners. Prologue 9

45 Contact Addresses II. Contact Addresses Manufacturer Distribution Distribution in USA Roche Diagnostics GmbH Sandhofer Straße Mannheim Germany Roche Diagnostics GmbH Sandhofer Straße Mannheim Germany Roche Diagnostics 9115 Hague Road Indianapolis, Indiana USA III. Warranty The warranty conditions are specified in the sales contract. Contact your Roche Diagnostics representative for further information. Any unauthorized modification of the Cedex Analyzer and/or the Cedex Software will result in invalidity of the guarantee and service contract. IV. Intended Use The Cedex Analyzer automatically determines the cell concentration and viability of cell suspensions. It must be used exclusively by laboratory professionals who are trained in laboratory techniques and have studied the Instructions for Use of this system. The Cedex Analyzer is for use in quality control/manufacturing processes only. It was neither developed nor validated by the manufacturer for any kind of in vitro diagnostic application. V. Software Disclaimer Portions of the CEDEX SOFTWARE might include one or more Open Source or Commercial Software programs. For copyright and other notices and licensing information regarding such Software programs included with CEDEX SOFTWARE please see the CD/ DVD provided with the product. 10 Cedex Analyzer Operator s Guide

46 Software License Agreement VI. Software License Agreement Read the following terms and conditions of this Software License Agreement ( Agreement ) carefully before installing the Cedex 2 Software, hereinafter referred to as ( Software ). Proceeding with the installation of the Software will constitute acceptance of the terms and conditions of this Agreement. By accepting the terms and conditions of this Agreement, the end user ( Licensee ) assumes all responsibility and liability for the selection of this Software to achieve the intended results, and for its installation and subsequent use. If Licensee is not willing to be bound by the terms and conditions of this Agreement, the Software package must be promptly returned to Roche ( Supplier ) with a copy of the receipt against refunding of the purchase price for this Software. 1. Program License Agreement Licensee assumes all responsibility and liability for the selection of this Software to achieve the intended results, and for its installation and subsequent use. The Software is protected by copyright. 2. Grant of Software License Supplier is entitled to grant to Licensee subject to continuous compliance with all the provisions hereinafter, a non-exclusive, single use license to use the Software upon the terms and conditions contained in this Agreement. Licensee may: a. Use the Software on workstations which have to be owned, leased or otherwise controlled by Licensee, whether in a network or other configuration. b. Transfer the Software by assigning the rights under this Agreement to another party, provided that the other party agrees in writing to accept the terms and conditions of this Agreement. In addition, Licensee must ensure that the copyright notice is maintained on the Software transferred. Licensee may not: a. Use the Software, in whole or in part, except as expressly provided in this Agreement. b. Use the Software on more than one workstation at a time. c. Copy, sell, or otherwise transfer the Software or assign its rights under this Agreement, in whole or in part, to another party, except as expressly provided in this Agreement. d. Rent, distribute, license or sublicense the Software. e. Create derivative works based on Software. f. Modify, adapt, translate, reverse engineer, decompile or disassemble the Software. Supplier reserves all rights not expressly granted herein, including, but not limited to, the rights to market the Software either directly, or through affiliates, distributors and/or third parties. For further information, please contact your local Roche Applied Science support organization. You will find the contact information on the following webpage: 3. Limited Warranty The Software is provided as is without warranty of any kind, either expressed or implied, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose. The entire risk as to the quality and performance of the Software is with Licensee, should the Software prove to be defective. Licensee assumes the entire costs of all necessary servicing, repair, or correction. However, Supplier warrants that the program media on which the Software is furnished is free from defects in materials and workmanship under normal use for a period of ninety (90) days from the date of delivery as evidenced by a copy of your receipt. SUPPLIER MAKES NO FURTHER WARRANTIES OR GUARANTEES NOR EXPLICIT NOR IMPLIED Prologue 11

47 Software License Agreement 4. Disclaimer of Warranties AS FAR AS PERMITTED UNDER THE GOVERNING LAW AS SET FORTH UNDER SECTION 11 OF THIS AGREEMENT THE WARRANTY SET FORTH IN THE PREVIOUS PARAGRAPH, IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, ARISING BY LAW, FROM A COURSE OF PERFORMANCE, A COURSE OF DEALING, TRADE USAGE, OR OTHERWISE. AS FAR AS PERMITTED UNDER THE GOVERNING LAW AS SET FORTH UNDER SECTION 11 OF THIS AGREEMENT SUPPLIER AND ANY ENTITY CONTROLLING, CONTROLLED BY OR UNDER COMMON CONTROL WITH SUPPLIER ( SUPPLIER S AFFILIATE ) SPECIFICALLY DISCLAIM, WITHOUT LIMITATION, ALL WARRANTIES OF ANY KIND, WHETHER EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON INFRINGEMENT. SUPPLIER AND SUPPLIER S AFFILIATES MAKE NO REPRESENTATION OR WARRANTY AS TO THE SOFTWARE OR AS TO THE RESULTS TO BE ATTAINED BY LICENSEE OR ANY THIRD PARTY FROM THE SOFTWARE. LICENSEE ACKNOWLEDGES THAT IT HAS NOT RELIED UPON ANY REPRESENTATIONS OR WARRANTIES MADE BY SUPPLIER OR A SUPPLIER S AFFILIATE EXCEPT FOR THOSE EXPRESSLY AND SPECIFICALLY SET FORTH IN THIS AGREEMENT. 5. Limitations of Remedies Supplier s sole liability and Licensee s sole remedy shall be: a. The replacement of the program media not meeting Supplier s limited warranty and which is returned to Supplier with a copy of Licensee s receipt; b. If Supplier is unable to deliver replacement of program media which is free of defects in material and workmanship, Licensee may terminate this Agreement by returning the Software and a copy of Licensee s receipt to Supplier, and Licensee s money will be refunded. IN NO EVENT WILL SUPPLIER OR ANY OF SUPPLIER S AFFILIATES (OR THEIR RESPECTIVE OFFICERS, EMPLOYEES, CONSULTANTS, ATTORNEYS OR AGENTS), BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOST PROFITS, LOST DATA OR INFORMATION, LOSS OF USE OF THE SOFTWARE, BUSINESS INTERRUPTION, LOSS OF BUSINESS REPUTATION OR GOODWILL, OR DOWNTIME COSTS) WHICH THE LICENSEE OR THIRD PARTIES MAY INCUR OR EXPERIENCE, DIRECTLY OR INDIRECTLY ARISING OUT OF OR RELATING TO THE SOFTWARE, THIS AGREEMENT, OR THE TERMINATION OF THIS AGREEMENT, EVEN IF SUPPLIER OR A SUPPLIER S AFFILIATE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND NOTWITHSTANDING ANY FAILURE OF ESSENTIAL PURPOSE. THE AGGREGATE LIABILITY, ON A COMBINED BASIS, OF SUPPLIER AND SUPPLIER S AFFILIATES (AND THEIR RESPECTIVE OFFICERS, EMPLOYEES CONSULTANTS, ATTORNEYS, AND AGENTS) FOR DAMAGES FOR ANY CAUSE WHATSOEVER DIRECTLY OR INDIRECTLY RELATING TO OR ARISING OUT OF THIS AGREEMENT OR THE SOFTWARE, AND REGARDLESS OF THE FORM OF ACTION, SHALL BE LIMITED TO, AT SUPPLIER S OPTION, REPLACEMENT OF THE SOFTWARE OR REFUND OF THE FEES RECEIVED BY SUPPLIER OR A SUPPLIER S AFFILIATE FROM LICENSEE WITH RESPECT TO THE SOFTWARE. 6. General Information Licensee may not sublicense, assign or transfer the license or the Software, in whole or in part, except as expressly provided in this Agreement. Any attempt otherwise to sublicense, assign or transfer any of the rights, duties or obligations hereunder is void. 12 Cedex Analyzer Operator s Guide

48 Software License Agreement 7. Intellectual Property Rights Licensee shall only hold those rights to the Software that are expressly described in Section 2 of this Agreement. Any other rights with regard to the Software, including without limitation, ownership rights and patent, copyright, trademark, trade secret and other intellectual property rights, shall remain the sole property of Supplier. Licensee will not remove from the Software any references to copyrights, trademarks or other ownership rights, or cover up or alter any such references. Licensee will take all reasonable steps to prevent any unauthorized use, reproduction, sale, or publication of the Software or the unauthorized provision of access thereto. Licensee will indemnify and hold harmless Supplier from any losses, damages, claims and expenses (including, without limitation, reasonable legal expenses) relating to any infringement of the rights of Supplier caused by Licensee, Licensee s breach of this Agreement or Licensee s use of the Software in a manner not authorized under this Agreement. 8. Duration and Termination The Agreement is effective until terminated. Licensee may terminate this Agreement at any time by destroying the Software and documentation relating to the Software in any form. The Agreement will terminate automatically and without notice from Supplier, if Licensee fails to comply with any term or condition of this Agreement. Licensee agrees to destroy the Software upon termination of this Agreement by Supplier. On any termination of this Agreement, all rights of use of the Software held by Licensee shall expire. 9. Import, Export and Use of the Software Licensee shall be exclusively responsible for ensuring compliance with the relevant legislation relating to its rights to import, export or use the Software. 10. Miscellaneous Should any part of this Agreement be declared void or unenforceable by a court of competent jurisdiction, the remaining terms shall remain in full force and effect. Failure of Supplier to enforce any of its rights in this Agreement shall not be considered a waiver of its rights, including but not limited to its rights to respond to subsequent breaches. By opening and using this Software Licensee acknowledges that he has read this Agreement, understands it, and agrees to be bound by its terms and conditions. Licensee further agrees that this Agreement is the complete and exclusive statement of the Agreement between Licensee and Supplier and supersedes any proposal or prior agreement, oral or written, any other communications between Licensee and Supplier relating to the subject matter of this Agreement. The headings of the several Sections of this Agreement are intended for convenience of reference only and are not intended to be a part of or to affect the meaning or interpretation of this Agreement. 11. Governing Law and Place of Jurisdiction This Agreement shall be governed by and construed in accordance with the laws of Germany, without giving effect to any choice of law principles thereof. The parties agree that the United Nations Convention on Contracts for the International Sale of Goods (1980) is specifically excluded from application to this Agreement. The parties agree that courts of Mannheim, Germany, shall have exclusive jurisdiction over any dispute arising out of or in connection with this Agreement. Prologue 13

49 Preamble VII. Preamble Before setting up operation of the Cedex Analyzer, it is important to read this Operator s Guide thoroughly and completely. Non-observance of the instructions contained herein or performing an operation not stated in this Operator s Guide could involve safety hazards. VIII. Contents of this Operator s Guide This Operator s Guide describes the operation of the Cedex Analyzer. It contains the following chapters: Chapter A Overview presents the specifications of the Cedex Analyzer. Chapter B System Description contains the installation requirements of the Cedex Analyzer and a description of the system s components. This chapter also gives a short overview of the basic functions and operation of the system. Chapter C Operation describes the operating procedures for the Cedex Analyzer, including the correct placement of the reagents and disposables and instructions for carrying out single and multiple measurements of cell samples. Chapter D Software provides a detailed description of the Cedex Analyzer Software functions and features. Chapter E Maintenance and Care describes the maintenance and care procedures that are required for the Cedex Analyzer. Chapter F Troubleshooting contains troubleshooting information for the Cedex Analyzer. Chapter G Appendix contains a detailed list of System Options and User Preferences, and an Index. 14 Cedex Analyzer Operator s Guide

50 Conventions Used in this Guide IX. Conventions Used in this Guide Text Conventions To present information consistently and memorably, the following text conventions are used in this Operator s Guide: Numbered list: Italic type: Blue italic type: Steps in a procedure that must be performed in the order listed. Used for operating instructions for the Cedex Software. In addition, important notes and information notes are shown in italic type. Refers to a different section in this Operator s Guide, which should be consulted. Symbols In this Operator s Guide, the following symbols are used as visual signals: Symbol Heading Description WARNING IMPORTANT NOTE This symbol is used to indicate that non-compliance with instructions or procedures could lead to physical injury or even death or could cause damage to the system. Information critical to the success of the procedure or use of the product. INFORMATION NOTE Additional information about the current topic or procedure. ccc Procedure continued on next page. End of procedure. The following symbols appear on the analyzer: Symbol Heading Description CE MARK The CE mark on the Analyzer type plate indicates conformity with requirements of the directives relevant for this Analyzer. DANGEROUS ELECTRICAL VOLTAGE On the back of the Analyzer near the power box. Prologue 15

51 Warnings and Precautions X. Warnings and Precautions Moving parts may cause hand injuries. Never use the Cedex Analyzer without the protective cover on the Multi Sampler and Syringe Module. It is important that the following safety instructions and guidelines be observed in order to ensure safe and reliable operation of the Cedex Analyzer: c In an emergency, immediately turn the power switch off and unplug the instrument. c Place the device on a dry and sturdy surface, free of vibrations. c Avoid transporting the device as much as possible once it has been assembled. c Prevent the device from getting wet. c Protect the device from dust and smoke. c Do not expose the device to direct sunlight. c Ensure there is sufficient air circulation around the Cedex Analyzer during operation (particularly around the computer and monitor). c Operate within a constant temperature range of +10 C to +40 C (+50 F to +100 F). c For best performance, it is recommended to keep the Cedex Analyzer permanently on and only shut down the Software application on a regular basis. c The Cedex Analyzer should only be used with the supplied or specified devices (Cedex Analyzer, Cedex Software, monitor, computer, Multi Sampler, Reagent Tray). c Do not install any additional Software on the corresponding computer. c Only trained personnel in a controlled laboratory environment should operate the Cedex Analyzer. c All services and repairs should be performed only by authorized service technicians. c Always ensure that there are sufficient reagents in the reagent containers. c Clean the containers before reusing them. c Always observe the safety regulations when handling Trypan Blue, Detergent, Cleaning Solution or acids and bases. c Waste contaminated with tissue or cells, for example Cedex Sample Cups, pipette tips, etc., must be disposed of according to the recommended rules for handling biohazard materials. c Any leaks in the Liquid Management system must be repaired immediately. Contact your distributor or authorized service technician. c Always ensure that there is a Cedex Sample Cup attached to the single sample port or placed in the DefaultCup position on the Multi Sample Tray. c Only use Cedex Detergent for the cleaning process in the Liquid Management system. c Only use Cedex Sample Cups from Roche Diagnostics GmbH for the conveyance of cell samples to the sample port. Other sample cups can cause irreparable damage to the Cedex Analyzer! c Always wear protective clothing, particularly gloves, when handling samples. c To prevent damage to the flow chamber, no particles larger than 80 μm should enter the measurement system. c Particles (especially microcarriers) larger than 90 μm should not gain access into the Analyzer because they cause irreparable damage and render the device non-functional. c Dirt or dust particles should not gain access into the device. c Ensure that all equipment required for sample preparation, for example, Cedex Sample Cups, pipette tips, etc., are stored in a dust-free environment since coarse dust particles can impair the flow chamber s functionality. c Check that the Cedex Sample Cup is free of contamination before use. Only clean Cedex Sample Cups can guarantee optimal functioning of the Cedex Analyzer. c Ensure that the Trypan Blue solution is free of contamination, otherwise filter prior to use. Roche recommends the use of the Cedex Reagent Kit. c Secure your measurement data. 16 Cedex Analyzer Operator s Guide

52 Warnings and Precautions Installed anti-virus software should never be set up to scan the complete Cedex2 directory and especially not the FDB file itself. If the system has been upgraded from some previous version to Software version 2.3.2, it is possible that some default settings in the System Options may have slightly different values than those described in this manual. The settings described in this manual apply to systems on which Software version has been installed as the original Software. The Software and hardware of your Cedex System can differ from the information described here, but this should not make a difference to the operational functions in general. The manufacturer is not responsible or liable for any damages resulting from improper use or failure to comply with the regulations in the Operating Instructions. FCC Notification Changes or modifications to this unit not expressly approved by the party responsible for compliance may void the user s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate frequency energy and, if not installed and used in accordance with the Instruction Manual, may cause harmful interference to radio communications. Operating this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. Electrical Safety The Cedex Analyzer is designed in accordance with Protection Class I (IEC). The chassis/housing of the instrument is grounded to protection earth (PE) by means of a cord. For protection against electrical shock hazards, the instrument must be directly connected to an approved power source such as a three-wire grounded receptacle for the 110 V or 230 V line. Do not use an ungrounded receptacle; have a qualified electrician replace the ungrounded receptacle with a properly (PE) grounded receptacle in accordance with the local electrical code. Do not use an extension. Any break in the electrical ground path, whether inside or outside the instrument, could be hazardous. Under no circumstances should the user attempt to modify or deliberately defeat the safety features of this instrument. If the power cord becomes cracked, frayed, broken, or otherwise damaged, replace it immediately with the equivalent part from Roche Diagnostics. Malfunction due to interfering electromagnetic fields Malfunction of system and incorrect results due to interfering electromagnetic fields This system is designed and tested to CISPR 11 Class A standard. In a domestic environment it may cause radio interference, in which case, you may need to take measures to mitigate the interference. c The electromagnetic environment should be evaluated prior to operation of the device. c Do not operate this system in close proximity to sources of strong electromagnetic fields (for example unshielded intentional RF sources), as they may interfere with proper operations. Prologue 17

53 Disposal of the Analyzer XI. Disposal of the Analyzer Disposal Recommendations All electrical and electronic products should be disposed of separately from the municipal waste system. Proper disposal of your old appliance prevents potential negative consequences for the environment and human health. The Analyzer must be treated as biologically contaminated hazardous waste. Decontamination (i.e., a combination of processes, including cleaning, disinfection and/or sterilization) is required before reuse, recycling, or disposal. Dispose of the Analyzer according to local and/or laboratory regulations. For more information contact your local Roche Support personnel. Disposal of control unit components This symbol appears on any component of your control unit (such as the computer, monitor, or keyboard) that is covered by the European Directive on Waste Electrical and Electronic Equipment (WEEE). You must dispose of these items through designated collection facilities appointed by government or local authorities. Contact your city office, waste disposal service, or your Roche Service representative for more information about disposal of your old product. Constraint: It is left to the responsible laboratory organization to determine whether control unit components are contaminated or not. If contaminated, treat them in the same way as the system. 18 Cedex Analyzer Operator s Guide

54 A Overview The Cedex Analyzer automatically determines the cell concentration and viability of cell suspensions. The analysis is based on the Trypan Blue Exclusion Method whereby cell suspensions are stained and analyzed. The data obtained allows for the evaluation of the overall state of the cell culture, including the specific growth rate and doubling time of a cell population, as well as the documentation of the cultivation process. A The evaluation of the samples is based on automatically obtained digital images that are analyzed using analysis Software on a separate computer (Cedex Control Unit). All the necessary steps from the staining of the samples to the recording and evaluation of the image data are automatically performed by the Analyzer. Recognition and differentiation of cells as either viable or dead is done under standardized conditions, which provides very precise and objective results. A variety of parameters, including Viable Concentration, Total Concentration, Viability, Average Compactness and Average Diameter are analyzed using result data from single images, as well as from all of the selected images of a sample. Standard deviation (Std. Dev.) of the number of cells from image to image is also calculated. In addition, the Aggregate Rate, which shows the percentage of the total number of cells that appear in aggregates (clusters), is determined for both single images and all of the images. The use of a Live Operator makes it possible to directly observe the effects on the analysis of a sample when the image analysis Software (Operator) is adjusted. Graphical representations of the measurement results can be viewed in the Measurement Statistics Histogram, Diameter Histogram, Compactness Histogram, Aggregate Histogram and Cultivation Time Chart. In the Measurement Statistics Histogram, individual images can be compared to give a better overview of the distribution of the cells in the images. The Cell Diameter Histogram shows the diameter distribution of living cells. The deviation of the shape of living cells from that of an ideal sphere is represented in the Compactness Histogram. The Aggregate Histogram provides an overview of the amount and size of aggregation found in the cell culture. The Cultivation Time Chart displays growth curves and cultivation parameters in a time-dependent manner. The results of the Cultivation Time Chart can be separately printed out. For further processing of the results in other programs, data export in formats such as Excel-compatible formats and CSV (Comma Separated Values, generally applicable) is possible. The Cultivation Time Chart includes calculations for the doubling time [T] and specific growth rate [µ]. The Cedex Software is operated on Windows 7. Secure data handling, as well as a carefully designed user management system, guarantee compatibility with 21 CFR, Part 11. Access security for the Cedex Analyzer has been stepped up. Access is only allowed for authorized persons. The workstation can be automatically blocked after a certain number of consecutive entries of a false password via the Systems Options. A warning message will appear before the last allowed attempt. Contact your local Roche service representative for more information about setting up the Cedex System to be compliant with 21 CFR Part 11. Overview 19

55 Description of the Cedex System A 1 Description of the Cedex System The Cedex System consists of two functional units, the Analyzer (see Figure 1) and the Control Unit (computer equipped with the Cedex Software 2.3.2). Preparation and processing of the samples takes place in the Analyzer. The analysis Software is installed on a computer and controls the Analyzer, as well as the analysis and evaluation of the images obtained. Syringe Module with 8-way valve Sample port with Cedex Sample Cup 2.5 ml syringe ON/OFF switch Reagent Tray with 5 reagent containers (from left to right: Trypan Blue, Detergent, Cleaning Solution, distilled or deionized Water, Waste) Figure 1: The Cedex Analyzer The Analyzer consists of two main components, the hardware for image capturing and the Liquid Management system. The flow chamber is specially developed to allow for the analysis of a defined volume of cell suspension. The Liquid Management system is responsible for staining the sample as well as for filling and cleaning the flow chamber and liquid feed system. The volumes of sample and dye, as well as specific cleaning solutions required for each cleaning routine, are precisely controlled via the Syringe Module with the 8-way distribution valve. The individual components of the Liquid Management system are easily accessible to allow for trouble-free maintenance and control. 20 Cedex Analyzer Operator s Guide

56 The Measurement Procedure The Trypan Blue Exclusion Method 2 The Measurement Procedure The determination of the number of viable cells (cells/ml) and viability of cell suspensions (the percentage of viable cells from the total cell sample) is a fully automated, stand ardized procedure based on the manual Trypan Blue Exclusion Method. A defined volume of Trypan Blue is added by the syringe to the Cedex Sample Cup containing the cell suspension. The cell suspension and dye are optimally mixed between the syringe and Cedex Sample Cup by controlled pump actions and then incubated for exactly the same amount of time for each measurement. This minimizes effects on the viability measurements that might be caused by the toxicity of the Trypan Blue. A After the incubation period, the stained cell suspension in the syringe is then transported in small portions through the capillary tubes and 8-way valve to the flow chamber. A set number of microscopic images of the cell sample is taken in the flow chamber and transferred to the analysis Software via an integrated interface in the measurement system. Once the measurement procedure is completed, the Liquid Management system automatically performs a cleaning routine. It is only possible to begin a new measurement after the cleaning routine has finished. 2.1 The Trypan Blue Exclusion Method The Trypan Blue Exclusion Method is based on the principle that viable cells will not take up the dye, while dead or dying cells have a compromised membrane that allows for the uptake of the dye. Thus, dead cells appear darkly stained in a microscope. Trypan Blue has a greater affinity for serum proteins than cellular proteins. If the microscopic image has a dark background due to high quantities of stained serum proteins, centrifuge the cell sample and resuspend it in a protein-free medium or physiological saline solution prior to counting. Overview 21

57 Data Analysis A 3 Data Analysis The analysis Software and its graphical user interface (GUI), known as the Cedex Control Center, enables the user to work with the Cedex Analyzer. The image analysis Software (Operator) recognizes structures and identifies particles, thus differentiating cells from cell debris and dirt particles. Live and dead cells are differentiated according to their degree of Trypan Blue staining. Image processing is integrated in the Cedex Control Center in such a way that the user or Administrator can check on its function in the system. The analysis process cannot be altered during data recording in order to allow for consistent and objective measurement results. 22 Cedex Analyzer Operator s Guide

58 Technical Specifications of the Analyzer 4 Technical Specifications of the Analyzer Cedex Analyzer Method of measurement Digital image and pattern recognition A Viable/dead cell differentiation Detectable cell concentration range Trypan Blue Exclusion Method cells per ml Detectable cell diameter range 8 µm 40 µm Required sample volume 1,000 µl Average measurement period Geometric resolution < 4.0 min 2.08 µm/pixel Chamber height 100 µm Material and diameter of the capillaries Operating temperature (Optimal image quality is achieved between 20 C and 30 C) Maximum temperature change Maximum humidity deviation Operating humidity Teflon, 765 µm +10 C to + 40 C 5 C per hour 5% per hour 20% 80% relative humidity (non-condensing) Pollution degree 2 (according to IEC ) Dimensions Energy requirements Energy consumption Height: 660 mm (26.0 inches) Width: 300 mm (12.0 inches) Depth: 600 mm (23.6 inches) Weight without Multi Sampler: 33.0 kg (72.6 lbs) VAC, Hz 24 VDC 2.0 A Installation category II (according to IEC ) Overview 23

59 Technical Specifications of the Analyzer A Multi Sampler MS20C (optional) Number of samples 1 20 Average measurement period for 20 samples (20 images per sample) Dimensions < 90 min Height: 250 mm (9.84 inches) Width: 250 mm (9.84 inches) Depth: 190 mm (7.48 inches) Total Weight: 5.2 kg (11 Ibs) Energy requirements Energy consumption 24 VDC, 9A DC max. 30W Power supply Input: VAC, Hz Output: 24 VDC Hardware Requirements for the Cedex Control Unit Computer x86-architecture, Intel Pentium IV, Minimum 2 GHz required 3 GHz recommended Operating system Windows 7 RAM Hard-disk storage Serial ports Minimum 2 GB RAM 100 MB free hard-disk storage for installation of application Minimum 20 GB free hard-disk space for data storage of approx. 1,000 measurements Recommended: 80 GB Minimum 2 free ports (minimum 3 free ports if MS20/AS20 installed) Frame grabber Eltec PC-eye 4 CD/DVD burner Graphic card Monitor (color monitor or -TFT) Minimum CD burner required DVD burner recommended if the computer will not be connected to a server Resolution: pixel, 24-bit color pixel, 24-bit color 24 Cedex Analyzer Operator s Guide

60 Installing the Cedex System B System Description 1 Installing the Cedex System The Cedex System comprises the Cell Analyzer and the Control Unit (PC equipped with the Cedex Software 2.3). The Cell Analyzer and Control Unit are delivered and assembled by a service technician authorized by Roche Diagnostics GmbH. The service technician assembles the Cell Analyzer and controls the installation, runs the focus adjustments and ensures that the Cedex System is operational. Finally, the technician will create a report on the installation and current status of the device. We recommend choosing your local IT specialist as the system administrator for the general administration of the Windows operations. This person controls the configurations that regulate system access at the level of the operating system. B Installation of the Cedex System is done as follows: c The system administrator should set up net access and/or printer installation, if desired, before the service technician assembles the Cedex System. c The Cedex System is assembled by a service technician authorized by Roche Diagnostics GmbH. c The service technician installs the Analyzer and checks the settings in the Software. c The service technician checks the Software information, performs a focus adjustment and ensures that the Cedex System is ready to use. Finally, the technician creates a current status report of the device. c The system administrator is responsible for setting up the user accounts for the operating system. The system administrator is also responsible for ensuring data safety and security of the system. c The Administrator for the Cedex Software then sets up Cedex System user accounts and assigns users the appropriate rights (see Administration of User Accounts ). Please be aware that the correct operation of the Analyzer and Software can only be guaranteed if no other Software has been installed on the computer. The Software and hardware of your Cedex Analyzer may differ from the information described here, but this should not make a difference to the operational functions in general. Roche recommends only installing the software on the Control Unit and Windows Image version provided by Roche specifically for the Cedex System. Installations on other hardware will not be supported. For more details, please contact Roche Technical Service. Roche provides a secured remote service for the Cedex Control Unit that can be activated by Roche Technical Service. Please contact Roche Technical Service for more information. The Cedex Control Unit can be integrated into a network domain by activating some properties. This activation can be done by Roche Technical Service. Please contact Roche Technical Service for more information. System Description 25

61 Choosing a Suitable Location Connecting Hardware Components 2 Choosing a Suitable Location The Cedex Analyzer is highly sensitive and consists of top-quality electronic and optical components. To guarantee optimal and reliable performance of the Cedex Analyzer, select the appropriate location in accordance with the safety regulations described in the Prologue. B Avoid further transportation of the Cedex Analyzer after the installation. Vibrations or shaking must be avoided when operating or transporting the analyzer over short distances. Focus adjustment must be done after transportation (see Automatic Adjustment ). Injury from heavy loads The Cedex Analyzer weighs 33 kg (72.6 lbs). No attempt should be made by the user to remove or set up the instrument alone. You may injure your hands, fingers, or back when putting the Analyzer in place. 2.1 Connecting Hardware Components Follow the instructions below to connect the hardware components (see Figures 2 and 3 below): 1 Connect monitor, keyboard and mouse to their respective ports on the PC. 2 Connect one end of the video cable to the Video port of the measurement system. 3 Connect the other end of the video cable to the Video port of the PC. 4 Connect one end of the first serial cable to the Focus port of the measurement system. 5 Connect the other end of the first serial cable to the Focus port of the PC. 6 Connect one end of the second serial cable to the Syringe port of the measurement system. 7 Connect the other end of the second serial cable to the Syringe port of the PC. Check that your connections are correct otherwise an error message will appear: Error: HWManager Pump connection failed or Error: Device Pump is not connected. 26 Cedex Analyzer Operator s Guide

62 Choosing a Suitable Location Connecting Hardware Components B Figure 2: Cedex Analyzer connections Figure 3: PC connections Connect the measurement system, PC and monitor to the main power supply with the supplied cords. The power supply should not be located in the area around the sample, and should be placed at all times behind the Cedex Analyzer. Liquids must never come into contact with the power supply. System Description 27

63 Connecting or Disconnecting the Device 3 Connecting or Disconnecting the Device First, connect the device using the power cord to the external power supply. A blue power switch is located on the front panel of the Cedex System. When the switch is turned to ON it illuminates, indicating that the device is live. In case of problems, turn the device switch to OFF. B In case of emergency, remove the power line from the Cedex System immediately. ON/OFF switch Figure 4: The ON/OFF switch for the Cedex Analyzer 28 Cedex Analyzer Operator s Guide

64 Updating to Cedex Software or Installing the Cedex Software Overview 4 Updating to Cedex Software or Installing the Cedex Software Roche strongly recommends that the procedures described in this chapter for installing or updating to Cedex Software only be carried out by a trained IT specialist. The Cedex Software is installed on the Control Unit delivered with the Cedex System. If the Cedex Software is already installed on your Control Unit, and the system has been installed in your lab, please refer to Section C, Chapter 2, Preparing the Analyzer for Measurements, for information about starting up an installed system. B 4.1 Overview The procedure required to update to Cedex Software version varies depending on the version of the Cedex Software installed on the Control Unit. The flowchart in Figure 5, located on the next page, provides an overview of the steps that must be taken, depending on the Software version. Before beginning the update procedure, please review the flowchart in Figure 5 carefully and refer to the relevant overview sub-chapters for further information. The steps described in this chapter must be followed exactly in order to guarantee correct installation of the Software. Do not turn off the Control Unit (PC) throughout the installation procedure. If there is any interruption during the installation procedure, a recovery of the entire Operating System will be required. The recovery DVD is located inside of the Control Unit above the CD drive, and the steps are described in Section B, Chapter 4.3, Update or Recover Windows Operating System to Windows 7. Please note that Cedex Software version requires Windows 7 operational software. In order to install Windows 7, the hard disk must be formatted, which will result in complete data loss. Therefore, all files to be backed up and saved must be stored in an external location before beginning installation of the Windows 7 image. System Description 29

65 Updating to Cedex Software or Installing the Cedex Software Overview Update to SW from Cedex SW 1.x Cedex SW 2.1.x or v.2.2.x Cedex SW 2.3.x B see overview Section B, Chap see overview Section B, Chap see overview Section B, Chap Contact your local Roche Technical Service for this update Update SW, inc. database, to Cedex SW 2.3.x (Instructions: Cedex Analyzer Operator s Guide; SW version 2.3, August 2013) Create backup of Cedex SW 2.3.x database (Section B, Chap. 4.2) Update or Recover Windows OS to Win7 (Section B, Chap. 4.3) Install the Framegrabber and Multi I/O drivers (see Section B, Chap. 4.4) Install Cedex SW (Section B, Chap. 4.5): c New database (Section B, Chap ), or c Existing database (Section B, Chap ) Create backup of Cedex SW 2.3.x database (Section B, Chap. 4.2) Update or Recover Windows OS to Win7 (Section B, Chap. 4.3) Install the Framegrabber and Multi I/O drivers (see Section B, Chap. 4.4) Install Cedex SW (Section B, Chap. 4.5): c New database (Section B, Chap ), or c Existing database (Section B, Chap ) Figure 5: Flowchart showing steps required for updating to Cedex SW Cedex Analyzer Operator s Guide

66 Updating to Cedex Software or Installing the Cedex Software Overview New install SW Including Win7 Update or Recover Windows OS to Win7 (Section B, Chap. 4.3) Install the Framegrabber and Multi I/O drivers (see Section B, Chap. 4.4) Install Cedex SW (Section B, Chap. 4.5): c New database (Section B, Chap ), or c Existing database (Section B, Chap ) Figure 6: Flowchart showing steps required for installing Cedex SW SW only Install the Framegrabber and Multi I/O drivers (see Section B, Chap. 4.4) Install Cedex SW (Section B, Chap. 4.5): c New database (Section B, Chap ), or c Existing database (Section B, Chap ) B System Description 31

67 Updating to Cedex Software or Installing the Cedex Software Overview Overview: Updating from Cedex Software 1.x to Cedex Software When updating a Cedex System from Software version 1.x to Software version 2.3.2, please contact Roche Technical Service for support. The procedure for this update is not described in this Operator s Guide. B Before proceeding with an update to Cedex Software version 2.3.2, ensure that: c You have administrator access to the Control Unit. c You have backed up all the files containing measurement data generated by measurements run on the Cedex Software 1.x. Before performing any form of installation or update procedure, the actual (effective) values for the FlowFactor and ChamberHeight must be saved and stored for future reference. These values may need to be adjusted in the System Options after the installation or update procedure is complete. The values for FlowFactor and ChamberHeight are located in the Cedex.ini file, located in the directory C:\Cedex. Contact your local Roche Technical Service for more information about accessing the Cedex.ini file. Cedex Software version uses a database system for storage of measurement results. Measurements performed with Cedex Software version 1.x are stored in a file folder format and cannot be imported into the Cedex Software 2.x database. Therefore, it is not possible to access measurements that were run on a Cedex System with Software version 1.x using Cedex Software version 2.x Overview: Updating from Cedex Software 2.1.x or 2.2.x to Cedex Software Before starting an update of your current Cedex Software version 2.1.x or 2.2.x to Cedex Software version 2.3.2, ensure that: c You have the complete required software packages, as well as the appropriate hardware, for the installation or update to Cedex Software Consult with your local Roche Technical Service in case of questions. c You have administrator access to the Control Unit. c A storage device with enough disk space is available for a backup of the current installation. Check the size of the folder containing all Cedex Software 2 files, including the database file (usually the directory C:\Cedex2). The size of the backup will be approximately the size of this folder. c Enough time is scheduled for a backup of the current installation (approximately one hour for backup to a fast external hard drive per 10 GB disk space used in the Cedex 2 directory, including the database file). Databases working with older Cedex Software 2.x must be updated to Cedex Software 2.3.x before they can be updated to Cedex Software Therefore, you must update your current 2.x Software version to version 2.3.x and back up the database after the update before beginning with the steps described in the subsequent chapters. To update from Cedex Software version 2.1.x through 2.2.x to Cedex Software version 2.3.2, the following steps must be performed: c Create a backup of the database. c Update older Cedex Software version 2.x to Cedex Software 2.3.x, if not already updated. Please refer to Section B, Chapter 4.3, Updating Older Cedex Software Version 2.x to Cedex Software 2.3 in the Cedex Analyzer Operator s Guide; Software Version 2.3 (August 2013), located on the installation CD for Cedex Software in the folder User Additional Features/Manual, for step-by-step instructions for updating to Cedex Software version Cedex Analyzer Operator s Guide

68 Updating to Cedex Software or Installing the Cedex Software Overview c Follow the instructions provided in Section B of this Operator s Guide to update from Cedex Software 2.3.x to Cedex Software Refer to the overview chart shown in Figure 5 for a description of the steps required. Before performing any form of installation or update procedure, the actual (effective) values for the FlowFactor and ChamberHeight must be saved and stored for future reference. These values may need to be adjusted in the System Options after the installation or update procedure is complete. The value for FlowFactor is located in the System Options menu under the General tab. The value for the ChamberHeight is located in the System Options menu under the Hardware tab. See System Options and User Preferences in the Appendix for more information. Before updating or installing the software on a system with an existing database, ensure that you have created a backup of the Cedex Software database in a remote, secure storage device that is not part of the Control Unit. Also, ensure that you fully read and understand the following instructions before proceeding with the update or installation of the Cedex Software. If an error occurs or if you do something incorrectly, this could result in data loss and/or could prevent the Cedex Software from operating. B Overview: Updating from Cedex Software 2.3.x to Cedex Software Before starting an update of your current Cedex Software 2.3.x installation to Cedex Software version 2.3.2, ensure that: c You have the complete required software packages, as well as the appropriate hardware, for the installation or update to Cedex Software Consult with your local Roche Technical Service in case of questions. c You have administrator access to the Control Unit. c A storage device with enough disk space is available for a backup of the current installation. Check the size of the folder containing all Cedex Software 2 files, including the database file (usually the directory C:\Cedex2). The size of the backup will be approximately the size of this folder. c Enough time is scheduled for a backup of the current installation (approximately one hour for backup to a fast external hard drive per 10 GB disk space used in the Cedex 2 directory, including the database file). Before performing any form of installation or update procedure, the actual (effective) values for the FlowFactor and ChamberHeight must be saved and stored for future reference. These values may need to be adjusted in the System Options after the installation or update procedure is complete. The value for FlowFactor is located in the System Options menu under the General tab. The value for the ChamberHeight is located in the System Options menu under the Hardware tab. See System Options and User Preferences in the Appendix for more information. Before updating or installing the software on a system with an existing database, ensure that you have created a backup of the Cedex Software database in a remote, secure storage device that is not part of the Control Unit. Also, ensure that you fully read and understand the following instructions before proceeding with the update or installation of the Cedex Software. If an error occurs or if you do something incorrectly, this could result in data loss and/or could prevent the Cedex Software from operating. System Description 33

69 Updating to Cedex Software or Installing the Cedex Software Create a Backup of the Cedex Software Version 2.3.x Database 4.2 Create a Backup of the Cedex Software Version 2.3.x Database Please note that Cedex Software version requires Windows 7 operational software. In order to install Windows 7, the hard disc must be formatted, which will result in complete data loss. Therefore, the database must be backed up and saved in an external location before beginning installation of the Windows 7 image. B 1 Connect an external USB disk driver to the Cedex Control Unit. 2 Navigate to the folder C:\Cedex2. Right-click on the folder and select Copy to copy the entire Cedex2 folder. Figure 7 3 Navigate to the external UBS disk drive, right-click on the drive, and select Paste to add the Cedex2 folder to the external disk drive. Figure 8 This step can take several minutes or hours depending on the size of the database. 4 Disconnect the external disk drive and proceed to the next Chapter to update or recover Windows operating system to Windows Cedex Analyzer Operator s Guide

70 Updating to Cedex Software or Installing the Cedex Software Update or Recover Windows Operating System to Windows Update or Recover Windows Operating System to Windows 7 A recovery of the entire Operating System may be required if there is any interruption during the installation procedure. In addition, the following procedure is used to update a Control Unit to Windows 7 (e.g., a Control Unit with Windows XP Professional that is suitable for updating to Windows 7). When updating an existing Control Unit to Windows 7, the Windows 7 Recovery DVD may not be located inside the Control Unit. In such a case, locate the Windows 7 Recovery DVD and proceed from Step 5. To recover or update the Operating System to Windows 7 for the Cedex Analyzer Control Unit, do the following: 1 Shut down the Control Unit (PC) and monitor. B 2 Unplug and remove all cables from the Control Unit (power supply included). 3 Remove the cover by pressing on the side of the Control Unit and at the same time pulling the Control Unit to its front and pulling the cover up. Figure 9 4 The Windows 7 Recovery DVD is located on top of the CD drive, as shown below. Remove the Recovery DVD and replace the cover of the Control Unit. Figure 10 5 Replace the cover of the Control Unit, plug the cables for the keyboard, mouse and power supply into the Control Unit and turn it on. ccc System Description 35

71 Updating to Cedex Software or Installing the Cedex Software Update or Recover Windows Operating System to Windows 7 6 Insert the Recovery DVD. B Figure 11 7 Restart the Control Unit. 8 When the following HP welcome screen appears, press <F9> on the keyboard. Figure 12 9 In the following window, select CD-ROM as the Boot Device and press <Enter>. 10 Figure 13 A pre-installation screen appears and then a Windows 7 starting screen appears. Figure 14 ccc 36 Cedex Analyzer Operator s Guide

72 Updating to Cedex Software or Installing the Cedex Software Update or Recover Windows Operating System to Windows 7 11 In the following dialog box, press <1> on the keyboard to recover Windows 7 ( OS Recovery CEDEX ). B 12 Figure 15 Press Y if all required data are saved on an external medium, including the Cedex 2 database, if required. Otherwise, press N and go back to Section B, Chapter, 4.2, Create a Backup of the Cedex Software Version 2.3.x Database. 13 Figure 16 The following dialog box appears and the recovery starts. The entire recovery procedure takes approximately 10 minutes. Figure 17 ccc System Description 37

73 Updating to Cedex Software or Installing the Cedex Software Update or Recover Windows Operating System to Windows 7 14 At the end of the recovery, the following dialog box appears. Remove the DVD, and then press any key to continue. B 15 Figure 18 The Control Unit automatically reboots. 16 Figure 19 When the following screen appears, enter the correct date, time, and time zone. Click OK in the Date and Time dialog box. 38 Figure 20 Cedex Analyzer Operator s Guide ccc

74 Updating to Cedex Software or Installing the Cedex Software Update or Recover Windows Operating System to Windows 7 17 Enter the serial number of the instrument and click OK. 18 Figure 21 Press CTRL + ALT + DELETE to log in. Enter the default administrator username and password as follows: c Username: Win-Admin c Password: Win-Admin B Figure 22 The Windows Operating System is now updated to Windows 7, and the drivers can be installed. System Description 39

75 Updating to Cedex Software or Installing the Cedex Software Install the Frame Grabber and Multi I/O Drivers 4.4 Install the Frame Grabber and Multi I/O Drivers B Install the Frame Grabber and Multi I/O Drivers The driver for the Frame Grabber connection and Multi I/O(PCI Multiport Serial Controller) driver must be installed before the Cedex Software can be installed. 1 Connect the video (Frame Grabber) and the two serial cables to the Cedex Analyzer and the Control Unit, as shown below. Figure 23 Figure 24 If there is a Multi Sampler, connect the cable to one of the Perle Serial Ports (shown above). 2 Turn on the Cedex Analyzer by pressing the ON/OFF switch. When the switch is turned to ON, it illuminates, indicating that the device is live. 3 The Muliti I/O driver (Perle Card) is now automatically installed. Continue with Step 4 to install the driver for the Frame Grabber. 4 Simultaneously press the Windows key and the Pause/Break key. Alternatively, go to the Start menu and open the Control Panel -> System and Security -> System Click on the Device Manager icon. Figure 25 ccc 40 Cedex Analyzer Operator s Guide

76 Updating to Cedex Software or Installing the Cedex Software Install the Frame Grabber and Multi I/O Drivers 5 Right-click on Multimedia Control, located under Other devices, and select the option Update Driver Software. B Figure 26 6 Click on the option Browse my computer for driver software. Figure 27 7 Click on Browse, and select the folder Framegrabber located on the Control Unit under C:\drivers\Cedex Standard. Click OK. Figure 28 ccc System Description 41

77 Updating to Cedex Software or Installing the Cedex Software Install the Frame Grabber and Multi I/O Drivers 8 Click on Next, then click on Install this driver software anyway. B Figure 29 9 Click on Install. 10 Figure 30 The driver for the Frame Grabber card is successfully installed. Click on Close to exit the dialog box. Figure Cedex Analyzer Operator s Guide

78 Updating to Cedex Software or Installing the Cedex Software Install the Frame Grabber and Multi I/O Drivers Check the Driver Installation 1 Simultaneously press the Windows key and the Pause/Break key. Alternatively, go to the Start menu and open the Control Panel -> System and Security -> System Click on the Device Manager icon. B Figure 32 2 Check that the drivers are correctly installed by comparing the window to the following image. Figure 33 System Description 43

79 Updating to Cedex Software or Installing the Cedex Software Install Cedex Software Version Install Cedex Software Version Initiate the Software Installation 1 Insert the Cedex Software installation CD and double-click on the Cedex Setup exe program. B 2 Click on Install. Figure 34 3 Click on Next. If a window appears asking for administrator confirmation, click Yes and continue with the installation. Figure 35 4 Put a checkmark in the box I accept the terms in the license agreement and click on Next. Figure 36 ccc 44 Cedex Analyzer Operator s Guide

80 Updating to Cedex Software or Installing the Cedex Software Install Cedex Software Version Click on Next to install the Cedex Software 2.3 files into the recommended folder (C:\Cedex2). B Figure 37 6 Click on Install to initiate the installation. Figure 38 In case of a system on which a new database should be installed, proceed with Section B, Chapter 4.5.2, Install a New Database During Software Installation. In case of a system on which an existing database should be updated, proceed with Section B, Chapter 4.5.3, Update an Existing Database During Software Installation. System Description 45

81 Updating to Cedex Software or Installing the Cedex Software Install Cedex Software Version Install a New Database During Software Installation 1 If the software is being newly installed and a new database is required, place a checkmark in the Create new Database box. Click on Next. B Figure 39 If an existing database should be used for the installation, place a checkmark in the Use existing database box, and proceed with the instructions in Section B, Chapter 4.5.3, Update an Existing Database During Software Installation. 2 During the installation, the following Cedex 2.3 Configuration dialog box appears. Figure 40 To continue with the installation, enter the following information in this dialog box: a) Enter the serial number of the Cedex Analyzer (e.g., G037D9047). b) Enter a description of the system in the Description area (e.g., my system ). c) If a Multi Sampler is not installed, uncheck the use Auto/Multi Sampler AS20/MS20 checkbox. d) Verify the Cedex System Type in the Cedex System Type area. Figure 41 3 After completing all steps in the Cedex 2.3 Configuration dialog box, the Next button will become active. Click on Next to continue the installation. ccc 46 Cedex Analyzer Operator s Guide

82 Updating to Cedex Software or Installing the Cedex Software Install Cedex Software Version Click on Finish. B Figure 42 5 The Setup Successful dialog box will appear if the installation was completed successfully. Confirm with Close. Figure 43 System Description 47

83 Updating to Cedex Software or Installing the Cedex Software Install Cedex Software Version Update an Existing Database During Software Installation 1 If a database already exists and should be updated during the installation, put a checkmark in the Use existing Database box, and select the path of the needed database. Click on Next. B Figure 44 Note that the database to be used for this procedure must first be updated to Cedex Software v2.3.x and saved in that format. If a new database should be installed, place a checkmark in the Create new database box, and proceed with the instructions in Chapter B, Section 4.5.2, Install a New Database During Software Installation. 2 Click on Finish. Figure 45 3 The Setup Successful dialog box will appear if the installation was completed successfully. Confirm with OK. Figure Cedex Analyzer Operator s Guide

84 Updating to Cedex Software or Installing the Cedex Software Set the Cedex Server to Autostart 4.6 Set the Cedex Server to Autostart The Cedex Server must be started before the Cedex Client can be started. If desired, the Cedex Server can be configured to start automatically when the Control Unit is turned on. If not, continue with the next section. To configure the Cedex Server to autostart, do the following: 1 Open Windows Explorer by left-clicking on the Windows Start button, then right-clicking on All Programs and selecting Open All Users. B Figure 47 2 Copy the shortcut Cedex Server from the desktop to the Start Menu folder. Figure 48 3 Open the Properties dialog box for the Cedex Server by right-clicking on the icon and selecting Properties. Select the Shortcut tab and change the property for Run to Minimized via the drop-down menu. Click OK. Figure 49 Continue with Section B, Chapter 4.7 to start the Cedex Software for the first time after update or installation of the Cedex Software version System Description 49

85 Updating to Cedex Software or Installing the Cedex Software Start Cedex Software for the First Time After Installation 4.7 Start Cedex Software for the First Time After Installation Once the installation of the Cedex Software is complete, the Software can be started and final adjustments made. Do the following: 1 Reboot the Control Unit and wait until it is fully booted. B 2 After the Control Unit is booted, log into the Windows Operating System with the following username and password: c Username: Win-Admin c Password: Win-Admin 3 The Cedex Server is normally started during the Windows 7 startup, and the window is automatically minimized. If the Cedex Server has not automatically started, follow the instructions in Section B, Chapter 4.6 to set the Cedex Server to autostart. Alternatively, double-click on the Cedex Server shortcut on the desktop to start the Cedex Server. Figure 50 4 Double-click on the Cedex Client shortcut located on the desktop. 5 In the Log In dialog box, enter the following: c User Name: Superuser c Password: spass Figure 51 6 In the Cedex Control Center Event area, verify that the message Hardware startup completed appears. This step can take several minutes. Figure 52 ccc 50 Cedex Analyzer Operator s Guide

86 Updating to Cedex Software or Installing the Cedex Software Start Cedex Software for the First Time After Installation 7 In the following dialog box, click OK to confirm the error message. B Figure 53 8 Click OK in the following message list dialog box to confirm the error. Figure 54 9 In the Cedex Control Center, choose the Reagent Kit Status option from the Functions menu. Figure 55 ccc System Description 51

87 Updating to Cedex Software or Installing the Cedex Software Start Cedex Software for the First Time After Installation 10 In the Reagent Kit Status dialog box, click on Replace All Containers, and then click on Close to exit the dialog box. If needed, replace or refill the Reagent Kit containers. See Preparing the Analyzer for Measurements. B 11 Figure 56 Click Yes to exit the dialog box that appears. Figure Close the Cedex Control Center with the in the top-right corner, and click on Yes to confirm. Figure Close the Cedex Server dialog box with the in the top-right corner. Double-click on the Cedex Server shortcut on the desktop and verify that the message Server is working appears in the dialog box. 15 Figure 59 Double-click on the Cedex Client shortcut on the desktop, and log in with: c User Name: Superuser c Password: spass ccc 52 Cedex Analyzer Operator s Guide

88 Updating to Cedex Software or Installing the Cedex Software Start Cedex Software for the First Time After Installation 16 The following error message will appear because the Automatic Adjustment must be performed before measurements can be run (see Automatic Adjustment ). Click on OK to close the error message. B Figure 60 Click OK to acknowledge the second error message and close the dialog box. Figure In the Cedex Control Center Event area, verify that the message Hardware startup completed appears. Figure Verify that the system is not running in demo mode (i.e., make sure there is no Demo label visible in the Cedex Control Center). Each Cedex Analyzer has a few unique specifications related to the particular flow chamber that has been put in. These numbers must be verified and/or adjusted in the System Options dialog box before measurements can be run. Verify and/or make the following changes in the System Options dialog box under either the General or the Hardware tabs: a. Verify MultiSamplerPresent (0 = Single Port, 1 = Auto/Multi Sampler) in the Hardware tab. (this parameter can only be changed by reinstalling the software or with a service software). b. Enter the appropriate value for the ChamberHeight in the Hardware tab. c. Enter the appropriate value for the FlowFactor in the General tab. Click on Save and close the System Options dialog box with the in the top-right corner. ccc System Description 53

89 Updating to Cedex Software or Installing the Cedex Software Start Cedex Software for the First Time After Installation 21 Select Diagnosis in the Setup menu of the Cedex Control Center. B 22 Figure 63 Click on Start Diagnosis and verify that parameters entered in Step 19 are correct. Without Multi Sampler: Figure 64 With Multi Sampler: Figure Close the Diagnosis dialog box. The system is ready to be primed and to carry out an Automatic Adjustment (see Preparing the Analyzer for Measurements and Automatic Adjustment ). 54 Cedex Analyzer Operator s Guide

90 Starting the Cedex System 5 Starting the Cedex System The hardware components of the Cedex Analyzer must all be switched on before the analysis Software can be started, otherwise the Software will not be properly initialized. After the initial installation, switch on the individual devices in the order given below: 1 Switch on the Cedex Analyzer. 2 Switch on the monitor and the PC. B System Description 55

91 Securing Access Rights Access Control at the Windows Operating System Level 6 Securing Access Rights B 6.1 Access Control at the Windows Operating System Level We recommend choosing your local IT specialist as the system administrator for the general administration of the Windows operations. This person should undertake the configuration of the settings that regulate access to the system at the operating system level. One default user at the operating system level has been factory installed: c The Win-Admin user (default password Win-Admin) acts as system administrator for the operating system and has full access to all elements on the desktop including the ability to add/delete programs. For security reasons, the Win-Admin user at the Windows Operating System level should protect the access to the Windows OS with a new password directly after initial installation. 6.2 Access Control at the Cedex System Software Level To launch the Software, do the following: 1 Check that the Cedex Server Software has already been automatically started (it may appear as a minimized dialog box in the task bar at the bottom of the computer screen). If it has not automatically started, start the server by double-clicking on the Cedex Server icon on the desktop. 2 Start the Cedex Software by double-clicking the Cedex Client icon on the desktop (the Cedex Server must be successfully launched before the Cedex Client can be started). The Log In dialog box of the Cedex System will open. 3 Enter the username password in the respective fields. By default, the following users are available after installation: a. Superuser (password spass) b. Administrator (password apass) For the Cedex Software, there should generally be at least three levels of users. In addition to normal Cedex System users, who will only use the Cedex System for carrying out measurements, both a Cedex System Superuser and an Administrator should be appointed. The Cedex System Superuser assumes the main responsibility of handling the Cedex System, whereas the Administrator creates and administers user accounts. For security reasons, both the Administrator and the Superuser should protect their access to the Cedex Software 2.3 with new passwords after initial installation. Follow the instructions below to secure access and define a new password: 1 Log in as Administrator or Superuser. 2 Click on the System menu in the Cedex Control Center. 3 Click on Change own password. The Change Password dialog box will appear. 4 Enter the old password first. The new password needs to be entered twice. 5 Confirm by pressing OK. After logging in, users can change their own passwords at any time by following the same procedure. After installation, the user Administrator should set up regular user accounts and provide the necessary rights before regular users run measurements (see Administration of User Accounts ). For security reasons, the Cedex System Administrator is generally only accorded administrative rights and cannot carry out, reprocess or view measurements. 56 Cedex Analyzer Operator s Guide

92 Overview of the Cedex Control Center Menu Bar C Operation 1 Overview of the Cedex Control Center The Cedex Control Center is divided into three elements: c Menu bar c Shortcuts area c Event window detailing status of events carried out by the Analyzer A description of the individual areas is given below: C Figure 66: The Cedex Control Center 1.1 Menu Bar The menu bar at the top of the Cedex Control Center has 7 menu items: c System menu c Measurements menu c Functions menu c Reports menu c Master Data menu c Setup menu c Help menu 1.2 System Menu The menu items have the following functions: c Exit: exits the Cedex Control Center. c Logout: for logging out of the Cedex Control Center. c Change own password: for changing the password of a user who is logged in. c Lock Unlock System: for automatically or manually locking and unlocking of the system with regard to running measurements. Operation 57

93 Overview of the Cedex Control Center Measurement Menu 1.3 Measurement Menu The menu items have the following functions: c Measurement List: This provides a list of the measurements that have been run. Measurements can be sorted or filtered using specific criteria and then viewed (see Using the Measurement List ). c Single Measurement: Selecting this menu item will open a new dialog box in which single measurements can be run (see Opening the Measurement Dialog Box and Specifying the Operating Mode and Sample Data ). c Multi Run: Selecting this menu item will open a new dialog box in which multiple measurements can be run (see The Multi Run Data Entry Dialog Box ). c Cultivation Time Chart: This opens a new dialog box in which multiple measurements can be analyzed in a graph form (see Cultivation Time Chart ). C 1.4 Functions Menu The menu items have the following functions: c Reagent Kit Status: This dialog box shows the percent of each reagent left. Confirmation of a reagent change is also executed. c Operational Data: The operating hours, number of measurements and liquid consumption are tracked. c Cleaning Routines: Various cleaning routines can be run. c Syringe Maintenance: Used for preparing the syringe for removal and installation. c Hardware Management: Prime and shutdown of the Liquid Management, as well as startup and shutdown of the hardware, are executed. c Automatic Adjustment: An automatic focus adjustment is run. c SST: This opens a dialog box in which System Suitability Tests (SST) can be set up and executed. The status of SSTs are also displayed. c Scheduling: Automatic Prime, LM Shutdown and cleaning routines can be scheduled. c Export to File: Measurement results can be exported into various formats, including Excel. c Data Exchange: Data can be imported or exported from the database of one system to the database of another system. c Archiving: Data from the database can be archived or restored. 58 Cedex Analyzer Operator s Guide

94 Overview of the Cedex Control Center Reports Menu 1.5 Reports Menu Reports can be generated using this menu for the following types of information: c Operational Data c Measurement Data c System Configuration Parameters c Audit Trail c Report about the Multi Run c Automatic Adjustment and Alignment Verification 1.6 Master Data Menu The menu items have the following functions: c Reagent Container Configuration: This dialog box allows the user to set the minimum and maximum volumes for the reagents, as well as to set the volumes for the warning and lock levels. c User Preferences: The user preferences for default parameters such as measurement parameters, measurement lists and Cultivation Time Chart can be individually set. c Cell Type List: This allows for the creation of customized Cell Types. C 1.7 Setup Menu The menu items have the following functions: c Audit Trail: Opens a dialog box that tracks all actions of the system. c System Options: Various system parameters can be changed by the Superuser. c User and Rights Management: The Administrator can create new users and administer their rights. c Diagnosis: At the request of Roche Technical Service, a diagnosis of the entire system can be run with the options listed. c Trace and Logging: At the request of Roche Technical Service, logs of various functions of the system can be created. c Report Templates: Report templates can be created. Operation 59

95 Overview of the Cedex Control Center Help Menu 1.8 Help Menu The Help menu provides general information about the analysis Software. C 1.9 Shortcuts Area Several buttons that act as shortcuts to certain functions are available in this area, including: c List: Opens the Measurement List dialog box. c Measure: Opens the Measurement dialog box for running a single measurement. c Multi Run: Opens the Multi Run dialog box for running multiple measurements. c CTC: Opens the CTC Views dialog box for setting up Cultivation Time Charts. c SST: Opens the System Suitability Test List dialog box for setting up and executing SSTs. c Clean: Opens the Cleaning dialog box. c HWM: Opens the Hardware Management dialog box. c Log Out: Logs the user out of the Cedex Control Center Tracking of Status of Events Carried Out by the Analyzer In the Event window below the Shortcuts area, the status of events that have been carried out by the Analyzer is tracked. If, for example, a cleaning routine is run, the completion of the routine will be noted in this window. Previous events can be looked at by using the scroll bar on the right. The window is cleared each time the Software is shut down. 60 Cedex Analyzer Operator s Guide

96 Preparing the Analyzer for Measurements Switching On 2 Preparing the Analyzer for Measurements 2.1 Switching On Each element is switched on separately as follows: 1 Switch on the Cedex Analyzer. 2 Switch on the Multi Sampler (if available). 3 Switch on the monitor and the PC. Cedex Analyzer hardware components must be switched on before starting the analysis Software. Otherwise, the analysis Software may not be correctly initialized. 2.2 Logging In at the Computer Operating System Level A prompt for a username and password will appear on the computer when everything has been turned on correctly. The user should log in as Win-Admin, password Win-Admin unless a different Windows operating system account has been set up. C 2.3 Starting the Cedex Software To launch the Software, do the following: 1 Check that the Cedex Server Software has already automatically started (it may appear as a minimized dialog box in the task bar at the bottom of the computer screen). If not, start the server by double-clicking on the Cedex Server icon on the desktop. 2 Start the Cedex Software by double-clicking the Cedex Client icon on the desktop (the Cedex Server must be started before the Cedex Client can be started). The Log In dialog box of the Cedex Analyzer program will open. 3 Enter the username and password (if a password is required) in the respective fields. c Factory installed default user is Superuser (password spass). 4 If you are logging in for the first time under a new username, you may be forced to change your password. 5 Click on the OK button to log in or press <Return>. The Cedex Control Center appears after a successful login. The user may be prompted to create a new password the first time the Cedex Software is started. This serves the purpose of replacing the temporary password given to the user by the Administrator when the user account was created. Follow the program instructions or see Changing Own Password. The Administrator, Superuser or regular user has access to the assigned functions once he/she has logged into the Cedex Control Center. The regular user only has access rights to routine operations depending on the configurations set by the Administrator. Access rights may vary according to options chosen for each user account. Operation 61

97 Preparing the Analyzer for Measurements Performing a HW Startup and Prime 2.4 Performing a HW Startup and Prime Two elements of the Analyzer are usually shut down at the end of the day: the Hardware Management and the Liquid Management. When the Hardware Management is shut down, several elements of the Analyzer, such as the Multi Sampler and pump, are not yet initialized. A HW Startup will initialize hardware interfaces and must be done before a measurement can be performed. If a measurement is attempted before the Hardware Management has been started, an error message will appear, Cannot start a new process: Hardware Management is not started. The HW Startup may be automatically carried out when the Software is launched if the Administrator has set this up in the System Options. C In the case of the Liquid Management, the capillary tubes and syringe are filled with air or water when the Analyzer is first installed or any time an LM Shutdown has been performed (see, Carrying Out an LM Shutdown and HW Shutdown ). Performing a Prime fills the capillary tubes and 8-way valve with the appropriate reagents. All measurements are based on the capillary tubes having a precise amount of reagents in them. Since LM Shutdown should be run at the end of the previous day, a Prime is necessary prior to the first measurement of the day. If a measurement is attempted before the machine has been primed, an error message will appear, Cannot start new process: system is not primed. Both the HW Startup and the Prime functions are located in the same dialog box. Follow the instructions below to perform a HW Startup and Prime: 1 Click on the HWM button in the Cedex Control Center or select Hardware Management under the Functions menu. The Hardware Management dialog box will open. 2 If the Hardware Management has not been started, the current status field will have the message HW not started and LM not primed. 3 Click on HW Startup if required. The Hardware Management will start and the current status field will have the message HW started and LM not primed. 4 Ensure that a Reagent Kit is installed (see Preparing the Reagent Kit ) and a clean, empty Cedex Sample Cup is correctly attached to the sample port or correctly positioned on the Multi Sample Tray, if present (see The Multi Sampler DefaultCup ). 5 Click on Prime. The duration of a Prime procedure is displayed in the Estimated total time area. The time displayed is an estimate based on the time required for the previous Prime. The message HW started and LM primed, appears in the current status field when the Prime has been completed. 6 Click on to close the dialog box. There should not be a break of more than 2 hours between a Prime and a measurement. If more than 2 hours have passed since the last measurement, a new Prime must be performed. 62 Cedex Analyzer Operator s Guide

98 Preparing the Analyzer for Measurements Preparing the Reagent Kit 2.5 Preparing the Reagent Kit To ensure optimal performance, the reagents must be free of impurities such as dust, crystals, biological material or fluff. The Roche Cedex Reagent Kit guarantees optimal handling with the best possible safety. One Reagent Kit pack is sufficient for approximately 100 measurements, including the standard cleaning routines Installing or Changing the Reagent Kit Proceed as follows to install or change the Reagent Kit: 1 Perform an LM Shutdown if the Liquid Management system has been primed (see Carrying Out an LM Shutdown and HW Shutdown ). 2 Open the new Reagent Kit and place the Reagent Kit containers in the appropriate positions on the reagent tray (see Figure 67). 3 Fill the water reagent container with distilled or deionized water. 4 Empty, clean and replace the waste container. 5 Connect the capillaries to the reagent bottles through the holes in the lids. Ensure that the capillary tubes are not bent and almost reach the bottom of the containers. Use the lids to close the reagent containers to avoid dirt particles getting into contact with the reagents. The tubes should not be shortened under any circumstances! C 6 Remove the lid of the waste container and ensure that the silicone and capillary tubes only reach about 1 cm into the container. 7 Select the Reagent Kit Status option in the Functions menu of the Cedex Control Center. The Reagent Kit Status dialog box will open. 8 Click on the Replace all containers button in the right-hand corner of the Reagent Kit Status dialog box to confirm the changing of the Reagent Kit (see Figure 68). The Reagent Control display at the bottom righthand corner of the Cedex Control Center will turn from red to green and indicate the number of runs left. 9 Attach a clean Cedex Sample Cup to the sample port (see Figure 69) or place it in the DefaultCup position on the Multi Sample Tray (see The Multi Sampler DefaultCup ). 10 Click on Prime in the Hardware Management dialog box. Operation 63

99 Preparing the Analyzer for Measurements Preparing the Reagent Kit Waste container Distilled or deionized Water container Cedex Cleaning Solution container Cedex Detergent container Cedex Trypan Blue Solution container C Figure 67: Position of the Reagent Tray with the individual containers Figure 68: Confirming change of the Reagent Kit For reliable functioning of the reagent control (correct number of possible measurements, or reporting an impending overflow of the waste container), it is critical that all of the reagent containers are correctly filled to the line with the appropriate liquid or, in the case of the waste container, completely emptied (see Refilling Containers Individually ). The changing of the reagents must then be confirmed appropriately in the Software as soon as the Reagent Tray has been put back into the chamber. Failure to do all of the above will result in a mismatch between the calculated reagents available as shown in the Reagent Control and the actual reagent amounts in the containers or space available in the waste container. The reagent control function that monitors reagent and waste levels can be turned off. See Disabling the Reagent Control, for more information. 64 Cedex Analyzer Operator s Guide

100 Preparing the Analyzer for Measurements Preparing the Reagent Kit Refilling Containers Individually In order to ensure optimal functioning of the Analyzer, each Reagent Kit container must be thoroughly cleaned before refilling. Impurities such as dust and fluff or contamination with microorganisms may thus be avoided. Reagents can be refilled, or emptied in the case of waste, on an individual basis. Each change can be individually confirmed by clicking on the respective Set Full button or Empty button, in the case of waste, in the Reagent Kit Status dialog box (see Figure 68). If you are using your own reagents, it may be necessary to filter them before use. Roche Diagnostics GmbH recommends using the Cedex Reagent Kit. To refill individual containers with reagents, follow the instructions below: 1 Rinse all reagent containers well before refilling. Ensure there are no impurities such as dust or fluff in the containers. 2 Fill the detergent container to the required level with Cedex Detergent (see label). Only Cedex Detergent or a detergent with identical specifications should be used for the cleaning procedures in order to prevent damage to the sensitive surface of the Liquid Management components. 3 Fill Cedex Cleaning Solution in the cleaning solution container to the required level (see label). C 4 Fill distilled or deionized water in the water container to the required level (see label). 5 Fill Cedex 0.2% Trypan Blue solution in the Trypan Blue container to the required level (see label). Roche recommends using 0.2% Trypan Blue solution. If necessary, dilute a more concentrated Trypan Blue solution with buffer (Phosphate Buffered Saline (PBS), ph 7.4). 6 Place all of the reagent containers, as well as the emptied waste container, in the appropriate positions in the Reagent Tray (see Figure 67). 7 A Cedex Sample Cup should always be attached to the single sample port (see Figure 69). The Cedex Sample Cup (4 ml) is correctly attached when it is in an upright position beneath the sample port and the capillary tube almost reaches the bottom of the Cedex Sample Cup. If there is a Multi Sampler connected to the Analyzer, a Cedex Sample Cup must be placed in the DefaultCup position on the Multi Sample Tray (see The Multi Sampler DefaultCup ). Operation 65

101 Preparing the Analyzer for Measurments Checking the Analyzer 2.6 Checking the Analyzer Since measurement results obtained with the Cedex Analyzer depend on correctly filled reagent containers and the proper performance of the Analyzer, the user should check the Analyzer for possible wear and tear, and also check whether the reagent containers have the correct volume prior to each set of measurements, as follows: C 1 Check the Syringe Module (2.5 ml syringe and 8-way valve) for wear and tear or contamination. Renew the syringe if required (see Syringe Maintenance ). 2 Check the number of runs possible. This is listed in the right-hand corner of the Cedex Control Center next to a green or red circle. Change the Reagent Kit when required. Observe the reminder to change the Reagent Kit (see Installing or Changing the Reagent Kit ). 3 Check whether there is an empty Cedex Sample Cup attached to the sample port or a Cedex Sample Cup in the DefaultCup position on the Multi Sample Tray in the case of a Multi Sampler (see Working with the Multi Sampler ). If there isn t, attach one. 4 Perform a Hardware Management (HW) Startup if necessary. 5 Perform a Prime if a Reagent Kit is installed and new measurements are to be carried out (see Performing a HW Startup and Prime ). 6 Have the cell suspension samples or particle solutions ready for the analysis. 66 Cedex Analyzer Operator s Guide

102 Carrying Out a Single Measurement 3 Carrying Out a Single Measurement The following section describes the procedure for carrying out a single measurement. For setting up and carrying out multiple measurements, see Working with the Multi Sampler. A number of relevant parameters and entries must be specified in the Measurement dialog box prior to carrying out measurements. They include: c Choosing the operating mode and specifying sample data. c Defining the measurement and analysis (process) parameters. The measurement procedure can only begin when the steps above have been completed. Perform a HW Startup and Prime prior to the first measurement if the Liquid and Hardware Management system were previously shut down (see Performing a HW Startup and Prime ). C Operation 67

103 Carrying Out a Single Measurement Opening the Measurement Dialog Box and Specifying the Operating Mode and Sample Data 3.1 Opening the Measurement Dialog Box and Specifying the Operating Mode and Sample Data The entry areas for choosing the desired operation and specifying the sample data are located in the Sample Parameters and Processing parameters areas of the Measurement dialog box. The parameters should be entered just before measuring in order to ensure a direct relationship between the sample and the data. Follow the instructions below to specify sample data for a single measurement: C 1 Open the Measurement dialog box by clicking on the Measure button in the Shortcuts area or by selecting Single Measurement in the Measurements menu. 2 Enter a clearly defined Reactor ID to describe the sample (e.g., the name of the cell culture) in the Reactor ID area. You may either choose a Reactor ID from the drop-down list or enter a new Reactor ID. A new entry can be defined by up to 20 alpha numerical symbols. 3 Enter a clearly defined Sample ID in the Sample ID area (e.g., P001). The Sample ID can be freely defined. If the intended measurement is not the first in a row of measurements (i.e., if it has the same Reactor ID as a previous measurement), then the Software will automatically enter the consecutive Sample ID into the Sample ID area (e.g., P001, P002,...). In that case, it is not necessary to enter the Sample ID manually unless a different Sample ID is desired. 4 If desired, use the Sample Drawing drop-down menu to select the date when the sample was drawn. Note that the process date and time (i.e., the date and time the sample was measured), is automatically entered. 5 Choose the appropriate dilution factor from the Dilution drop-down list (e.g., 1:1, 1:2, 1:5, etc.). When a dilution of 1:2 is prepared, then 1 part cell suspension has been added to 1 part dilution medium. A dilution of 1:5 means that 1 part cell suspension has been added to 4 parts dilution medium. For undiluted samples, a dilution factor of 1:1 should be entered. It may be necessary to dilute samples with very high cell densities ( > cells/ml) manually prior to measuring. The dilution ratio chosen from the dropdown list only relates to the manual dilution of the sample prior to placing the sample on the system. Dilutions that are an automatic part of the measurement process in the Analyzer are already taken into account by the Cedex Analyzer Software. The calculations are carried out automatically and have nothing to do with the entered dilutions. 6 Select the sample volume of 1000 µl in the Volume drop-down menu. Only the 1000 µl option is available for the Cedex Analyzer. 7 The System name, as well as the process date and time of the assignment, will be automatically transferred to the Processing parameters area in the Measurement dialog box. 8 Entering a comment for a measurement is optional. Enter the remarks in the Comment box on the Sample Identification parameters area, if desired. 68 Cedex Analyzer Operator s Guide

104 Carrying Out a Single Measurement Defining the Measurement and Analysis (Process) Parameters 3.2 Defining the Measurement and Analysis (Process) Parameters The measurement and analysis parameters are defined in the Processing Parameters area of the Measurement dialog box. In principle, all routine measurements can be carried out using the standardized default settings that are factory set. To change the settings, follow the instructions below: 1 Select the sample port type in the Sample Port drop-down list: c Auto: this option will only appear on systems with Multi Samplers. c Single: this option will only appear on systems with a single sample port. 2 Manually enter the cup position for the sample in the Cup Position dialog box if there is a Multi Sampler (see Working with the Multi Sampler ). In the case of single measurements run via the Measurement dialog box on a Cedex Analyzer with a Multi Sampler attached, the Software will automatically incrementally increase the sample cup position number with each new measurement. The cup position can also be fixed (see Turning Off Automatic Incrementation of Sample Cup Position ). 3 Select the Cell Type that optimally recognizes your cells from the Cell Type drop-down list (see Adjustment of the Image Analysis Using the Live Operator ). The following Cell Type is available by default: c Std. Cells (V5.00) for normal sized cells with a diameter of about 12 µm (e.g., HB58). If a new Cell Type has been created, it can also be selected from the same Cell Type drop-down list. See Adjustment of the Image Analysis Using the Live Operator for more detailed information about creating new Cell Types. 4 Select the desired precision level in the Precision drop-down list. The precision level determines the volume to be analyzed. A higher analyzed volume will require a some what longer measurement time but more cells will be counted, which will lead to a more precise calculation. c Minimum: approximately 10 images are used for the analysis. c Normal: approximately 20 images are used for the analysis. c Superior: approximately 30 images are used for the analysis. The precision names may appear differently if the system has been upgraded from some previous version to Software version In the case of a system that has been upgraded to version 2.3.2, the precision levels may be called Low (corres ponding to Minimum), Medium (corresponding to Normal) and High (corresponding to Superior). The same volumes are analyzed for the corresponding levels. 5 Prepare the sample and attach the Cedex Sample Cup containing the sample to the sample port or place it in the appropriate spot on the Multi Sample Tray (see Preparing the Sample and Attaching it to the Multi Sample Tray or Sample Port ). C Operation 69

105 Carrying Out a Single Measurement Preparing the Sample and Attaching it to the Multi Sample Tray or Sample Port 3.3 Preparing the Sample and Attaching it to the Multi Sample Tray or Sample Port Prepare the sample prior to measuring according to the following instructions: 1 Transfer the selected volume of a well-mixed cell suspension to a clean Cedex Sample Cup. The Cedex Analyzer tolerates volume variations of +/-10%. Any greater variation in sample volume will lead to inaccurate results, and the Reagent Control monitor will no longer function correctly. The Cedex Analyzer can determine cell concentrations in the range of cells/ml. Any higher concentration requires a manual dilution. Cells with a diameter range of between 8 µm 40 µm can be assessed accurately. 2 Remove the present Cedex Sample Cup from the sample port (or Multi Sample Tray). C 3 Attach the prepared Cedex Sample Cup containing the cell suspension to the sample port (see Figure 69; the Cedex Sample Cup is correctly attached to the sample port when it is in an upright position directly beneath it and the capillary tube almost reaches the base of the Cedex Sample Cup) or place in the appropriate cup position on the Multi Sample Tray (see Figure 71). Figure 69: Attaching the Cedex Sample Cup to the sample port Starting the Measurement Ensure that the entire measurement system, including the sample, is ready for a measurement as follows: 1 Ensure that the Cedex Sample Cup is correctly attached to the sample port or placed on the Multi Sample Tray. 2 Ensure that the reagent containers are sufficiently filled and in their correct positions. 3 Ensure that the waste container is empty. 4 Click on Start Measurement in the middle of the Measurement dialog box to begin the measurement. During the measurement, samples of the cell/trypan Blue mixture are injected into the flow chamber in successive steps. After each injection, an image of the sample is taken and sent to the computer for analysis. The number of images taken depends on the precision level determined for the measurement. 70 Cedex Analyzer Operator s Guide

106 Carrying Out a Single Measurement Preparing the Sample and Attaching it to the Multi Sample Tray or Sample Port End of Measurement A cleaning procedure automatically begins immediately after the last image is captured and the results have been displayed in the Measurement dialog box. The entire Liquid Management system is rinsed during this procedure (Ultra Fast Clean). Once this procedure is completed, a green bar appears in the Measurement dialog box. In addition, the message Process finished EndEvent (Measurement) appears in the Event dialog box on the Cedex Control Center. In the Measurement dialog box, the top section of the Result Data area displays the overall results of the measurement. The bottom section displays, in succession, the results from each image taken. When a line is selected in the list of results of single images, the corresponding image is displayed in the Image area (see Image Area ). C Figure 70: Cedex Analyzer Measurement dialog box with the final results The measurement results can be directly printed out via the Print button in the middle of the Measurement dialog box. To set up a new measurement, click on the New Measurement button in the middle of the Measurement dialog box. If the next measurement belongs to the same Reactor ID as previous measurements, then the consecutive Sample ID will automatically be entered into the Sample ID area by the analysis Software without further entries being necessary. If a different Sample ID is desired, the new Sample ID can be typed in manually. Operation 71

107 Carrying Out a Single Measurement Interrupting a Measurement When the final measurement in a set of samples has been completed, or if there is a longer pause before the next measurement, perform a Standard Clean in the Liquid Management system in addition to the Ultra Fast Clean procedure that is automatically carried out between measurements (see Cleaning Options ). If multiple users have been created for the Cedex Software, log out of the Software once the clean ing procedure has been completed to allow the next user access to the Cedex Analyzer. The Cedex Sample Cup from the last measurement should remain attached to the sample port or left in the Multi Sample Tray in the DefaultCup position during the complete cleaning procedure. The cup should only be removed when a new Cedex Sample Cup has been attached for the next measurement. C If the Cedex Analyzer is to be shut down after a set of measurements, or at the end of the day, clean the complete Liquid Management system with an LM Shutdown procedure to maximize the life-span of the Cedex Analyzer and guarantee optimal performance. The entire Liquid Management system is rinsed with distilled or deionized water during the LM Shutdown, and the Trypan Blue is then pumped out of the capillary (see Carrying Out an LM Shutdown and HW Shutdown ). 3.4 Interrupting a Measurement An orange EMERGENCY STOP button is located on the left-hand side of the Measurement dialog box and can be activated during the measuring procedure to interrupt the analysis process. If the EMERGENCY STOP is selected, an error message will appear asking, Do you want to cancel the process?. Click on Yes to stop to stop and abort the process immediately. Click on No to put the process on hold. If Yes is selected, the EMERGENCY STOP button will change to read Unlock Queue. The system must be unlocked by clicking on this button before more measurements can be run. If No is selected, the EMERGENCY STOP button will change to read Resume. Click on this button to resume the measurement process. Only use the EMERGENCY STOP button in an emergency. Actual measurement data may be lost. 72 Cedex Analyzer Operator s Guide

108 Working with the Multi Sampler 4 Working with the Multi Sampler Moving parts of the Multi Sampler may cause hand injuries. The Multi Sampler needle may cause injuries during operation. Never use the Cedex Analyzer without the protective cover in place for the Multi Sampler. The Multi Sampler is an accessory device for the Cedex Analyzer (see Figure 71 and Figure 72). The Multi Sampler can convey up to 20 cell suspension samples in sequence to the Cedex System for analysis. Once the samples have been loaded in the Multi Sample Tray and the analysis parameters for each sample have been set, the samples are automatically delivered to the Cedex System and analyzed. Protective Cover C Sampling probe Cedex Sample Cups Multi Sample Tray Figure 71: Multi Sampler Operation 73

109 Working with the Multi Sampler The Multi Sampler DefaultCup C Sampling probe Multi Sample Tray Figure 72: Cedex Analyzer including Multi Sampler 4.1 The Multi Sampler DefaultCup The position of the Cedex Sample Cup used for the Prime, LM Shutdown, calibration and cleaning routines is called the DefaultCup. This sample cup does not differ from the usual Cedex Sample Cups. The standard (default) position for the DefaultCup is position 1 of the Multi Sample Tray. The 20 numbered positions are clearly marked directly on the Multi Sample Tray. An empty Cedex Sample Cup must be manually placed in the position set for the DefaultCup before running LM Shutdown, focus adjustment, Prime and all cleaning routines. The position in which the DefaultCup is placed can be changed. See Modifying the Standard Setting for the Multi Sampler DefaultCup. The position of the DefaultCup does not influence measurements. All 20 positions on the Multi Sample Tray can be used for measurements. However, should a sample be present in the DefaultCup position during Prime, LM Shutdown, focus adjustment or any cleaning routines, it can no longer be used for a measurement. 74 Cedex Analyzer Operator s Guide

110 Working with the Multi Sampler Preparing the Measurement 4.2 Preparing the Measurement Using the Multi Sample Tray Fill the appropriate volume of samples into Cedex Sample Cups (maximum 20) and place them on the Multi Sample Tray according to the desired sequence. Gently insert the tray into the notch until the automatic tray rope starts pulling it in. As a safety precaution, leave all of the empty Cedex Sample Cups in the Multi Sample Tray after the measurements have been completed Ejecting the Multi Sample Tray To eject the Multi Sample Tray, gently push on the right-hand corner of the tray when the system is idle. The Multi Sample Tray can be ejected by gently pushing on the tray only when the system is idle. The tray cannot be ejected if the system is moving or the needle is down in a cup. If a problem occurs with the system when the needle is down (see, for example, Disruption of Measurements ), restart the Hardware Management to render the tray ejectable again (see Carrying Out an LM Shutdown and HW Shutdown ). In some cases it may be necessary to restart the Cedex Software and Analyzer. C Performing a Prime The Prime and HW Startup are performed as usual in the Liquid Management dialog box as described in Performing a HW Startup and Prime. An empty Cedex Sample Cup must be placed in the DefaultCup position (default position 1) of the Multi Sample Tray when running a Prime. 4.3 Carrying Out Measurements with the Multi Sampler Before carrying out measurements, ensure that the system is operational as described in Checking the Analyzer The Multi Run Data Entry Dialog Box Click on the Multi Run button in the Shortcuts area of the Cedex Control Center or select Multi Run in the Measurements menu. The Multi Run dialog box will appear, and entries for sample data and parameters for the analysis process are entered via this dialog box (see Figure 73). In addition to the entry columns for ReactorID, SampleID, Cell Type, Dilution and Precision (see Opening the Measurement Dialog Box and Specifying the Operating Mode and Sample Data for more details), there are also columns for Status and CupNr. The CupNr column shows the sample cup position on the Multi Sample Tray. The Status column displays the state of the sample before, during and at the end of a measurement. Operation 75

111 Working with the Multi Sampler Carrying Out Measurements with the Multi Sampler Preparing for Multiple Measurements in the Multi Run Dialog Box The Multi Run dialog box automatically displays all 20 possible sample cup positions. To set up and carry out multiple measurements with the Multi Run do the following: 1 Transfer 1000 µl of a cell suspension sample into Cedex Sample Cups and place the cups in the desired locations on the Multi Sample Tray. 2 Click anywhere in the row of the MultiRun Measurements Preparation area that corresponds to the location of a Cedex Sample Cup containing a sample. The row will be converted to edit mode, and the sample and process parameters for the measurement can be defined (see Opening the Measurement Dialog Box and Specifying the Operating Mode and Sample Data and Figure 44). 3 Enter the desired sample data and parameters for the sample (see Defining the Measurement and Analysis (Process) Parameters ). C 4 Enter a comment in the field Comment, if desired. 5 Repeat Steps 2 4 for the remaining samples to be measured. 6 The rows in which entries are in the process of being filled out will remain in edit mode. To clear the entire list of entries and start with a new list, click on the Clear List button on the right-hand side of the Multi Run dialog box. Measurement of up to 20 samples in a row leads to prolonged incubation (up to 90 minutes) of cells at room temperature. Tests in our lab using several different cell lines (CHO-K1 and several hybridoma cell lines) showed no noteworthy influence of the prolonged incubation times on the measurement results. However, this result may not necessarily apply to all cell lines available on the market. We, therefore, recommend testing especially sensitive cell lines in advance to determine the number of samples that can be measured in a row without affecting the cells. Figure 73: Adding sample information to the Multi Run dialog box 76 Cedex Analyzer Operator s Guide

112 Working with the Multi Sampler Carrying Out Measurements with the Multi Sampler Activating Sample Rows and Starting the Measurement After all sample information has been entered in the Multi Run preparation area, the samples can be activated and, thus, added to the process queue. To activate samples and start the measurement, do the following: 1 Activate the status of each sample row by double-clicking in the Status field of the row to be activated. The row appears pale blue, and further modifications of sample information is impossible. Return to the Edit status by double-clicking on the Status area of the sample row to allow for further changes, if required. 2 Alternatively, all samples can be activated or deactivated simultaneously by double-clicking on the word Status in the column heading at the top of the Multi Run preparation area. Confirm the safety query with Yes to accept the modification. 3 After some or all rows have been activated, click on the Start button on the right-hand side of the Multi Run dialog box to start the analysis of the activated measurements. When measuring begins, the row of the sample being measured will be highlighted in yellow, and the progress of the measurement will be tracked in the status column. When a measurement is finished, the row will be highlighted in green and status column will indicate Done. In addition, the estimated time required for the measurement is shown in the Estimated time remaining field. C Images taken of the sample are displayed in the upper right-hand corner of the Multi Run dialog box during the measurement. In addition, results for Total Cell Concentration, Viable Cell Concentration and Viability are displayed in the upper left-hand corner of the Multi Run dialog box during and after a measurement has finished. Before, during and after measuring, the Status column can display the following infor mation (see Figure 73 and Figure 116): Edit: Indicates that sample data is actively open for editing and is in the process of being edited. Sample data in edit mode has not yet been added to the process queue, and samples placed in positions in edit mode will not be analyzed when the Multi Run is started. Rows in edit mode are white. Active: Indicates that the sample is ready for analysis, which starts automatically once the Start button is pressed. Rows in active mode are highlighted light blue. Scheduled: All rows marked as active will be added to the process queue and converted to scheduled mode after pressing the Start button. Rows marked as edit will remain in edit mode. Prepare: Indicates that the system is preparing to measure the sample marked with this status. The row is highlighted in yellow. Measure: Indicates that the system is in the middle of carrying out a measurement of the sample marked with this status. The row is highlighted in yellow. Cleaning: Indicates that the system is carrying out the cleaning routine after a completion of a measurement. The row is highlighted in yellow. Done: indicates that measurement and analysis of a sample marked with this status has been completed successfully. The row is highlighted in green. Failed: The measurement of this cup has failed. Aborted: The measurement of this cup has been aborted by the user. No Cup: There was no cup at this position in the Multi Sampler when it was ready for measurement. Blocked: The lift was blocked when the cup should have been measured. The status of a particular measurement is tracked in the Status column. The Errors and messages dialog box gives a list of each step completed and any errors that may have occurred. Operation 77

113 Working with the Multi Sampler Carrying Out Measurements with the Multi Sampler C Figure 74: Multi Run dialog box during measurement Only samples that have the status of active or scheduled will be measured. Samples that are in edit mode have not yet been added to the process queue and will not be measured until they have been activated. If an automated cleaning has been scheduled via the Scheduler function, the cleaning routine has a lower priority than scheduled measurements and will be added to the process queue after all activated (status: active or scheduled) measurements have been carried out (see Scheduling Automatic Cleaning Routines for more information about automating cleaning routines). Note that measurement information placed in the Multi Run preparation area that have the status of edit are not added to the queue! Therefore, if a Cedex Sample Cup containing a sample is added to the Multi Sample Tray in the DefaultCup position, and the row for that sample is left in edit mode, the cup will be used for a cleaning routine should one be scheduled to be carried out at that time. It is therefore critical to ensure that a Cedex Sample Cup containing a sample to be measured is never placed in the DefaultCup position on the Multi Sample Tray and left in edit mode during a Multi Run. Samples placed in the DefaultCup position for measurement should be immediately set to active or scheduled in order to be added to the process queue and, thus, have precedence over all scheduled cleaning routines Adding Measurements to the List While Measurements are Running Sample rows in which data has not yet been entered can be filled out at any time while the Multi Run is running. In addition, sample rows containing finished measurements (status: done) can be cleared and prepared for a new measurement by double-clicking in the Status field of the row with the finished measurement. Sample data for a measurement cannot be modified after that measurement has begun. 78 Cedex Analyzer Operator s Guide

114 Working with the Multi Sampler Interrupting a Multi Run Modifying Data Entry, Changing Samples Information about the operation and process parameters for samples that have not yet been analyzed can be modified during the run. To modify information of measurements that are in active or schedule mode but have not yet been started, do the following: 1 Double-click on the Status field of the measurement to be modified. The status field will indicate that the sample is in edit mode. 2 Make desired changes to the measurement. 3 Double-click on the Status field to re-activate the measurement (status: active or scheduled). Wait until the Multi Sample Tray has stopped moving before changing the samples! Non-Linear Measurements in a Sample Series Measurements of activated samples are always done in a linear fashion following a sequence of If samples need to be analyzed individually and not in the usual linear ascending order of 1 20, the samples to be analyzed later should be inactivated and remain in the Edit status for the meantime. When all active samples in the sample tray are completed, subsequent measurements with the newly activated samples can begin. C LOAD DATA FROM XML The LOAD DATA FROM XML option is available in the Multi Run dialog box and can be used to upload sample and processing parameters simultaneously for multiple samples. For more information about this function, see the document, Using the Load Data from XML option, located in the folder User Additional Features\Load Data from XML on the Cedex Software CD. 4.4 Interrupting a Multi Run The Start button will switch to a Stop button after a Multi Run has started. Click on the Stop button to pause or stop the Multi Run. If a measurement is being carried out when the Stop button is pressed, that measurement will be completed. All scheduled measurements (status: scheduled) will switch to active mode, and the Stop button will revert to Start. Click on the Start button again to continue analysis of activated measurements. 4.5 Disruption of Measurements Error messages may appear if a sample can t be run. For example: c If a Cedex Sample Cup is not available in its position on the Multi Sample Tray during measurements, then the No Cup message will appear. c If the Multi Sample Tray is not inserted or not inserted correctly, then the Tray not inserted message will appear. Some errors may block the analysis of the rest of the measurements. The level of error that should stop the analysis of all samples can be determined using the Error Level drop-down list at the top of the Multi Run dialog box. The options for the level of error that will stop the analysis are: c Fatal: Only errors involving a system / hardware crash, when functionality is not available, will stop analysis. c Critical: Data loss or any other error that results in an invalid measurement will stop the analysis. c Error: Errors that do not result in an invalid measurement will stop the analysis. c Warning: Warning messages with information for the user will stop the analysis. c Message: Any message will stop the analysis. Operation 79

115 Working with the Multi Sampler Results 4.6 Results After a Multi Run has finished, the results for all measurements obtained by the Cedex Analyzer are stored and displayed as described in Using the Measurement List. In addition, some results for the measurements carried out are displayed in the Analyzed Measurements field at the bottom of the Multi Run dialog box The Multi Run Result List At the bottom of the Multi Run dialog box, the Analyzed Measurements field displays the list of results for measurements previously carried out. Measurements are listed in order of process time, from the newest measurements at the top of the list to the oldest measurements at the bottom. All measurements carried out using the Multi Run dialog box will be displayed in this field unless the Clear Resultlist button has been pressed. C Clicking on the Clear Resultlist button will clear all measurement results from the list. In addition, measurements displayed in this field can be restricted to only the measurements carried out by the user logged into the system (mine), measurements that have not yet been printed out (unprinted), and/or measurements carried out on that particular day (today). Measurement results can be printed out via the Print Report button located just above the Analyzed Measurements field (see Printing Reports for more information about print report options). The following information is shown in the result list: c User c Workarea c Reactor ID (classifying the cell sample) c Sample ID (naming the measurement) c Valid checkbox c Total cell concentration [ 10 5 cells/ml] c Viable cell concentration [ 10 5 cells/ml] c Viability [%] c Sample Drawing (defined by user, if desired) c Process Time (date and time sample was measured) c Comment (if added by the user) Other results, such as Average Diameter, can be added for display in the result list via the User Preferences (see Adjusting Result Display in the Measurement List and Multi Run Dialog Boxes ). Double-click on a measurement to view all results. If the result list has been cleared, previously carried out measurements can still be viewed, printed out and exported via the Measurement List dialog box (see Using the Measurement List ). 80 Cedex Analyzer Operator s Guide

116 Switching Off the Cedex Analyzer Carrying Out an LM Shutdown and HW Shutdown 5 Switching Off the Cedex Analyzer Switching off the Cedex Analyzer should always be carried out in the following order: 1 Carry out an LM Shutdown. 2 Shut down the analysis Software (optional, see note below regarding the use of the scheduler). 3 Shut down the operating system. 4 Switch off the individual devices at random. If Prime, LM Shutdown or routine cleaning routines have been scheduled via the scheduler, the Software application must be left on and the HW must be started (see Scheduling Automatic Cleaning Routines ). C 5.1 Carrying Out an LM Shutdown and HW Shutdown All of the capillary tubes in the Liquid Management system are cleaned and rinsed with distilled or deionized water during an LM Shutdown. In addition, the Trypan Blue is withdrawn from the 8-way valve/syringe and replaced with air. This is to prevent the capillary tubes and flow chamber from becoming damaged. The HW Shutdown shuts down several elements of the hardware system including the Multi Sampler (if present) and pump. Follow the instructions below to carry out an LM Shutdown: 1 Click on the HWM button in the Shortcuts area of the Cedex Control Center to open the Hardware Management dialog box. Alternatively, the Hardware Management dialog box can be opened by selecting Hardware Management in the Functions menu at the top of the Cedex Control Center (see Figure 75). 2 Click on the LM Shutdown button in the lower right-hand corner of the dialog box to shut down the Liquid Management. The estimated time required for the LM Shutdown is displayed in the Estimated Total Time section of the Hardware Management dialog box. 3 When everything has been shut down, the Current Status field will have the message HW started and LM not primed. If both the Liquid Management and the Hardware Management has been shut down, the message HW not started and LM not primed will appear. 4 Click on to close the dialog box. Figure 75: Hardware management dialog box Operation 81

117 Switching Off the Cedex Analyzer Logging Out 5.2 Logging Out To log out of the Cedex Control Center, select Logout under the System menu or click on the Logout button in the Cedex Control Center. If an LM Shutdown has not yet been carried out, the message, Do you really want to log out without performing an LM Shutdown?, will appear. Either click on Yes to log out immediately or click on No, perform an LM Shutdown, then log out. The Software will be ended and the login dialog box will reappear. Logout is possible during a measurement without influencing it. A message indicates that measurements are in progress. C 5.3 Shutting Down the Cedex Control Center Follow the instructions below: 1 Perform an LM Shutdown to shut down the Liquid Management system (see Carrying Out an LM Shutdown ). 2 Shut down the Software by selecting Exit under the System menu or by clicking on to close the dialog box. The security query, Do you really want to exit the Cedex Control Center?, will appear. 3 Click on Yes to shut down the program. Restarting the analysis Software is necessary for the next measurement session. If at all possible, the Analyzer should never be turned off. If it is necessary to turn it off, the Analyzer needs at least 2 hours to warm up before it can be used for measurements. 82 Cedex Analyzer Operator s Guide

118 Using the Measurement Results Dialog Box D Software 1 Using the Measurement Results Dialog Box Measurement results are displayed in the Measurement dialog box (see Figure 77). If a single measurement has been run using the Measurement dialog box, the analysis results obtained from that measurement are automatically displayed in the same dialog box after the analysis process has been completed. Measurement results from Multi Runs are displayed in the Multi Run result list until the list has been cleared. In addition, measurement results can be viewed via the Measurement List dialog box. To access this dialog box, click on the List button in the Shortcuts area of the Cedex Control Center or select Measurement List in the Measurements menu. The Measurement List dialog box will open, showing all of the measurements stored in the database (see Figure 76). See Using the Measurement List for more details about working with the Measurement List. D Figure 76: Measurement List dialog box To see the results of a particular measurement, highlight the row containing the measurement to be viewed by clicking on the field to the left of the appropriate line, then clicking on the View button in the bottom righthand corner. The Measurement dialog box will open with the results of that particular measurement. The Measurement dialog box has 4 separate sections (see Figure 77): c Result Data area c Sample Parameters area c Processing Parameters area c Image area Some of the obtained data can also be displayed as graphic diagrams by clicking on the Diagrams button (see Graphical Display of the Analysis Results and Cultivation Time Chart for more details). It is also possible to access the Live Operator from this dialog box by clicking on the Live Operator button (see Adjustment of the Image Analysis Using the Live Operator ). Software 83

119 Using the Measurement Results Dialog Box Result Data Area 1.1 Result Data Area The Result Data area in the bottom half of the Measurement dialog box has two separate sections: the section just below the words Result Data displays the overall results for the measurement, while the section further down displays the results for each image analyzed. D Figure 77: The Measurement dialog box with results The parameters shown in the Result Data area for both the overall results and individual image results include: c Viable Cell Conc. Value: Indicates the concentration of viable cells [ 10 5 cells/ml]. c Total Cell Conc. Value: Indicates the total cell concentration [ 10 5 cells/ml]. c Viability (%) Value: Indicates the proportion of viable cells (%) to the total number of cells (viable and dead cells). c Avg Compactness Value: Indicates the average variation, in shape, of viable cells from an ideal sphere, with the ideal sphere shape equaling >1<. Higher values indicate the extent of variation and, therefore, the overall state of the cell culture (e.g., damage caused by shear force, etc.). c Average Diameter Value: Indicates the average diameter of viable cells [µm]. c Aggregate Rate Value: Indicates the percentage of all cells (Total Cell Count) present in aggregates (cell clusters). c Dead Cell Conc. Value: Indicates the dead cell concentration [ 10 5 cells/ml]. c Viable Cell Count Value: Indicates the number of viable cells counted. c Dead Cell Count Value: Indicates the number of dead cells counted. c Total Object Count Value: The default image analysis software (Cell Type: Std. Cells (V5.00)) delivered with the Cedex Analyzer does not provide any detailed information about objects. 84 Cedex Analyzer Operator s Guide

120 Using the Measurement Results Dialog Box Sample Parameters and Processing Parameters Areas In addition, the Result Data area for the individual images has an Excluded column next to the image number. Images that could lead to incorrect measurement results during analysis (e.g., due to impurities or large bubbles), are automatically recognized as invalid and excluded from evaluation by the analysis Software. If this occurs, the image will be marked with a check in the checkbox of the Excluded column. Users can also manually exclude individual images from the calculations or include images that were automatically excluded by the Software by clicking on the checkbox in this column. 1.2 Sample Parameters and Processing Parameters Areas The Sample Parameters area of the Measurement dialog box shows the parameters entered by the user before running the measurement. If any measurements have been reprocessed, the original or reprocessed data can be selected in the drop-down menu of the Data Set section. If data has been reprocessed at some point, the Effective checkbox will indicate which data set has been determined to be the effective version (see The Reprocess Button ). Comments for the measurement can be added in this area at any time. The Processing Parameters area lists the process parameters of the measurement, including Cell Type, used to analyze the images (see Adjustment of the Image Analysis Using the Live Operator ), the precision selected and the date and time the process was run. None of the values in this area can be changed. Click on the Show parameters button below the Cell Type drop-down menu to open a dialog box that shows the actual Live Operator Parameters values used for that Cell Type (see Figure 78, below). D Figure 78: Dialog box displaying the Live Operator parameter settings for the Cell Type used for a measurement Software 85

121 Using the Measurement Results Dialog Box Image Area 1.3 Image Area Viewing Individual Cell Images The Cedex Software enables a close view of a single image or an enlarged display for evaluation. Individual images can be viewed in the Image area of the Measurement dialog box. The results from the individual images are listed at the bottom of the Measurement dialog box in the Result Data area. When a row with the results of a particular image is highlighted in this section, the image connected with those results is displayed in the Image area at the top right-hand corner of the Measurement dialog box. To see a different image in this area, click on a different row in the Result Data area. Only one image is displayed in the Image area in the Measurement dialog box. Alternatively, an overview of all cell images can be displayed by clicking on the Image List button beneath the Image area, which will display the Image List dialog box containing thumbnails of all of the images used for the calculation of results (see Figure 79, below). D Figure 79: Image List dialog box showing all images used for the analysis Double-click on an image in the Image List dialog box to open a new dialog box, called the Image View. This dialog box contains an enlarged version of the selected image, as well as some further options for viewing the image. Double-clicking on the image displayed in the Image area of the Measurement dialog box will also open the Image View dialog box. The image list also displays an image taken of the analyzed area in the flow chamber just before cells are introduced into the chamber (Prescan Image). This image can be used to check whether large impurities that might affect the image analysis are present in the analyzed area of the flow chamber. 86 Cedex Analyzer Operator s Guide

122 Using the Measurement Results Dialog Box Image Area Viewing a Cell Image Using the Image View Dialog Box It is possible to see which cells were marked viable and dead cells by the analysis Software via the Image View dialog box. The user can thus get a sense of how cell shapes and clusters have been evaluated by the Software. The Cedex Software offers various options for optimizing measurement results by adjusting the Operator used for the analysis. Thus, the image analysis Operator can be adjusted for abnormal cell culture images or for specific internal counting strategies. For more information about adjusting the image analysis, see Adjustment of the Image Analysis Using the Live Operator. The Image View offers the following information and options: c Viable Cells: number of viable cells. c Dead Cells: number of dead cells. c Show Circles checkbox: switches on/off the marking of cells recognized as living or dead. Viable cells are marked with a uniform green circle and dead cells are marked with a red circle. The circle diameter corresponds to the cell diameter. Aggregates are marked with a blue circle. c Zoom: image enlargement. c Brightness and contrast settings. c Navigating a dialog box when the image is enlarged (scroll bars appear at the bottom and right edge of the image when the image is zoomed in). c Scrolling through all of the images for a particular measurement using the arrows lower right-hand corner. in the D Figure 80: Viewing a cell image using the Image View dialog box Software 87

123 Using the Measurement Results Dialog Box Image Area Certain areas of the image can be enlarged by following the instructions below: 1 Place the mouse pointer on the top left-hand corner of the area to be enlarged. 2 Hold the left mouse button pressed down and move it to the lower right-hand corner of the area to be enlarged. 3 Release the mouse button; the selected area will fill the whole dialog box. Return to the original size of the image by following the instructions below: 1 Place the mouse pointer anywhere on the diagram. 2 Hold the left mouse button pressed down and form a box from the bottom right corner to the upper left corner. 3 Release the mouse button. The chart will then return to its original size. D Click on Close to shut the dialog box or use the button Excluding Images from the Evaluation Process/Including Excluded Images Images can be excluded from analysis by the user. Also, images that have been excluded automatically by the analysis Software (due to, for example, excessive bubbles or dirt) can be included in the result analysis, if desired. Exclusion and inclusion of images for a particular measurement are done via the checkbox in the Excluded column in the Result Data area of the Measurement dialog box. If there is a check in the Valid checkbox, the image is considered valid, which means that the cell image has been included in the calculation process. The user can choose to manually exclude the image by clicking on the checkbox in the Excluded column for the selected image. The image will still be marked as Valid, but will also be excluded from the calculation of results. No check in the Valid checkbox means that the cell image is not considered valid and has been automatically excluded from the calculation process. In that case, a checkmark will automatically appear in the Excluded column. To include an image that was excluded by the Software, click away the checkmark in the Excluded column. The image will still be marked as invalid via the lack of checkmark in the Valid checkbox, but will be included in the calculation of results. 88 Cedex Analyzer Operator s Guide

124 Using the Measurement List 2 Using the Measurement List Data from measurements that have been carried out and stored in the database can be accessed via the Measurement List dialog box. Open the Measurement List dialog box by either clicking on the List button in the Shortcuts area of the Cedex Control Center or by selecting Measurement List in the Measurements menu at the top of the Cedex Control Center. Measurements are stored in the order in which they were carried out, with the most recent measurement placed at the top of the list. Two types of information can be displayed in the list of measurements: information about sample and process parameters and information about some results. If there is no check in the Show measurement results box at the bottom left-hand corner of the dialog box, sample and process parameters for measurements are displayed (see Figure 81). D Figure 81: Measurement List dialog box displaying the Sample Identification and Process Parameters To see measurement results, click on the checkbox next to Show measurement results (see Figure 82). By default, the list displays the results for total cell concentration, viable cell concentration and viability. Other results, such as Average Diameter or Compactness, can be added for display in the result list of the Measurement List dialog box via the User Preferences (see Adjusting Result Display in the Measurement List and Multi Run Dialog Boxes ). Figure 82: Measurement List dialog box with the option Show measurement results selected Software 89

125 Using the Measurement List Viewing Existing Analysis Results A number of actions can be carried out in the Measurements List dialog box including searching for measurements using a variety of filters, viewing measurement sample and process parameters, viewing measurement results, printing reports, exporting measurements to a file and reprocessing measurements (see The Reprocess Button ). 2.1 Viewing Existing Analysis Results View existing data sets by double-clicking on the measurement or by highlighting the row containing the desired measurement and then clicking on the View button in the bottom right-hand corner of the Measurement List dialog box. This will open a Measurement dialog box containing all of the relevant data results for the selected measurement (see Using the Measurement Results Dialog Box ). 2.2 Searching for Measurements It is possible to search for measurements using a number of different filter criteria including sample drawing date, process date, Reactor ID, and Sample ID in the Filter By area at the top of the Measurement List dialog box. To search for measurements based on the sample drawing date or the process date, for example, do the following: D 1 Click on the drop-down menu button next to the Sample Drawing Date From or Process Date From sections. A calendar will appear in which the desired starting date for filtering can be selected. 2 When a date has been selected, a check will appear in the checkbox next to the date to indicate that a filter is active based on that date. 3 Click on the drop-down menu button next to the date in order to select the desired ending date. 4 Once the dates for filtering the measurements have been selected, click on the Find button in the upper right-hand corner of the Measurement List dialog box. 5 All of the measurements that match the dates given for sample drawing (using the Sample Drawing Date From section,) or that were run within the dates specified in the Process Date From section, will be displayed in the measurement list in the bottom half of the dialog box. It is possible to select measurements with regard to both sample drawing date and process date. If the desired dates for both the sample drawing dates and process dates are selected, only those measurements that meet all 4 date criteria will be displayed when the Find button is clicked on. Measurements can also be searched for based on Reactor ID and/or Sample ID by filling in the information in these sections of the Filter By area. In addition, measurements can be searched for based on user by typing in the user name in the User section, by work area (using the drop-down menu in the Workarea section), by data set (in the DataSet area) and by Cell Type (using the drop-down menu in the Cell Type section). If a measurement has been reprocessed, the original and all reprocessed versions of the measurement will be listed. The data set version of a particular measurement that has been selected as the Effective data set will have a check in the checkbox of the DSEffective column. The original data set of a particular measurement will have a check in the checkbox of the DSOriginal column (see Effective Data Sets ). 90 Cedex Analyzer Operator s Guide

126 Editing Existing Analysis Results/Data Sets The Reprocess Button 3 Editing Existing Analysis Results/Data Sets The Cedex Software allows for existing measurement results or data sets to be modified and reprocessed. These changes are done on existing Software data (image and analysis results) and, therefore, do not require any adjustments to the Analyzer. Existing measurement results can be edited via the Reprocess button in the lower right-hand corner of the Measurement List dialog box. 3.1 The Reprocess Button Reprocessing existing measurement results/data sets (i.e., viewing a set of image data and evaluating them with new analysis parameters), can be done in the Reprocess mode, which is only accessible to authorized system users. The reprocess mode offers the following options: c Enter, modify or delete a comment. c Correct the dilution (see Defining the Measurement and Analysis (Process) Parameters ). c Change the Cell Type (see Adjustment of the Image Analysis Using the Live Op era tor ). To reprocess a measurement, do the following: 1 Open the Measurement List dialog box by clicking on the List button in the Shortcuts area of the Cedex Control Center or by selecting the Measurement List option in the Measurements menu of the Cedex Control Center. 2 Highlight the row of the measurement to be reprocessed and click on the Reprocess button in the lower right-hand corner. A Measurement dialog box will open containing all of the result data for that measurement. D 3 Enter a new name for the data set in the DataSet section of the Sample Parameters area. 4 Make the desired changes to the new data set. Changes can be made with regard to the comment, dilution factor and Cell Type in the appropriate sections of the Sample Parameters and Processing Parameters areas. 5 Click on the Reprocess button in the center of the Measurement dialog box to start the reprocessing of the measurement based on the new parameters. 6 When the reprocessing is finished, a dialog box will open asking whether the new data set should be the effective data set (see Effective Data Sets ). A new data set is available once the evaluation has been completed. All changes can be retraced by viewing previously created data sets, which are shown in the Measurement List dialog box. The reprocessing procedure creates additional data sets. Original data is not overwritten. Reprocessing of previous measurements cannot be performed while the Cedex Analyzer is measuring a cell sample. Software 91

127 Editing Existing Analysis Results/Data Sets Effective Data Sets 3.2 Effective Data Sets When measurements are reprocessed, it is possible to label one of the resultant data sets as Effective. The Effective data set is the version of the measurement (original or reprocessed) that has the correct parameters. Once a data set has been selected as Effective, it will be labeled as such in the Measurement List dialog box. It is possible to later change which data set is labeled the Effective data set by doing the following: 1 Select the data set version of the measurement to be labeled Effective in the Measurement List dialog box. 2 Click on the Reprocess button. A Measurement dialog box will open containing the results for that data set. 3 Click on the box to the left of the word Effective in the Measurement dialog box. A check will appear in the box. 4 Close the Measurement dialog box. 5 Click on Find in the Measurement List dialog box to refresh the list; the newly selected data set will appear as the Effective data set. D 92 Cedex Analyzer Operator s Guide

128 Graphical Display of the Analysis Results Enlarging the Histograms 4 Graphical Display of the Analysis Results In addition to displaying the overall analysis values, the Cedex Software can also display graphic diagrams of the results. These diagrams can be viewed after the analysis is finished by clicking on the Diagrams button in the Result Data area of the Measurement dialog box. When the Diagrams button has been selected, the Diagram dialog box will open. Four different histograms are available: Aggregate Histogram, Cell Diameter Histogram, Compact Histogram, and Measurement Statistics. Click on the respective button to open the desired diagram. The Object Diameter Histogram function is present, but no data is delivered by the presently available Cell Type. All the results represented in the diagrams are based on valid images accepted for evaluation. This means that individual images may be sorted out due to poor quality (e.g., bubbles, dirt particles, etc.) in the interest of an accurate measurement result. This is done automatically by the analysis Software or manually by the user (see Excluding Images from the Evaluation Process/Including Excluded Images ). 4.1 Enlarging the Histograms Certain areas of the histograms can be enlarged by following the instructions below: 1 Place the mouse pointer on the top left-hand corner of the area to be enlarged. 2 Hold the left mouse button pressed down and move it to the lower right-hand corner of the area to be enlarged. 3 Release the mouse button and the selected area will fill the complete dialog box. D Return to the original size of the histogram by following the instructions below: 1 Place the mouse pointer anywhere on the diagram and right click with the mouse. 2 A small dialog box will open with the options Unzoom or Undo all Zoom/Pan. 3 If the chart was enlarged more than once, selecting Unzoom will reduce the image to the point before the last enlargement. Selecting Undo all Zoom/Pan will return the chart to its original size. In addition, the diagrams can be moved around within the dialog box by placing the mouse pointer anywhere in the diagram, holding down the middle mouse button and moving the mouse. Software 93

129 Graphical Display of the Analysis Results Aggregate Histogram 4.2 Aggregate Histogram The Cedex Analyzer offers an evaluation of aggregates in cell cultures. Click on the Aggregate Histogram button in the Histograms dialog box to open the corresponding Histogram dialog box. The Aggregate Histogram shows the number of cells in the cell culture found in aggregates, as well as how many cells each aggregate is composed of. Both the actual cell number and the percentage distribution can be displayed. D Figure 83: The Aggregate Histogram, detailed view (divided into living and dead cells), here: (absolute) number of cells The Number of Cells [#] identified is displayed on the y-axis and at the top of the bars. The Aggregate Size, in terms of the number of cells per aggregate, is given on the x-axis. Figure 83 shows, for example, that 148 living and 40 dead cells of all identified cells were found in aggregates of two cells. 94 Cedex Analyzer Operator s Guide

130 Graphical Display of the Analysis Results Aggregate Histogram The percentages can be displayed using the percent button. Figure 84: The Aggregate Histogram, detailed view (divided into living and dead cells), here: percentage distribution of cells The percentage of cells [%] found in aggregates compared to the total live or dead cell count is displayed on the y-axis. The aggregate size, in terms of the number of cells per aggregate, is given on the x-axis. Figure 84 shows, for example, that 3.66% of all living cells and 7.29% of all dead cells are found in aggregates of two cells. The Total Cell Count (living and dead cells combined) per aggregate is mapped in the histogram using the total button. Figure 85 shows, for example, that 188 cells of the measurement are found in aggregates of two cells. D Figure 85: The Aggregate Histogram, total view (sum of living and dead cells), here: number of cells Software 95

131 Graphical Display of the Analysis Results Cell Diameter Histrogram The percentage of cells found in aggregates, in relation to the total cell count, can be displayed using the percent button as is shown in Figure 86. D Figure 86: The Aggregate Histogram, total view (sum of living and dead cells), here: percentage of cells 4.3 Cell Diameter Histogram Clicking on the Cell Diameter Histogram button will bring up the Cell Diameter Histogram. The Cell Diameter Histogram represents living cells (!) with a definable diameter. This diagram is based on the single diameters of all cells in the measurement. Figure 87: Cell Diameter Histogram 96 Cedex Analyzer Operator s Guide

132 Graphical Display of the Analysis Results Object Diameter Histogram Defining Diameter Intervals in the Diameter Histogram The Cell Diameter Histogram has three sliders that can define separate diameter intervals. This allows for dividing a histogram into a maximum of four parts. The sliders can be activated by clicking on the corresponding boxes and moving the sliders to the desired positions. One can also define the margins of the intervals by entering the numerical values on the left-hand side of each slider. The borders of the first interval are defined by the minimum value and the first numerical value entered. The next two values define the upper borders of the second and third intervals. The fourth interval is defined by the upper border of the third interval and the maximum value. The number of viable cells, their percentage of the total viable cell number and the viable cell concentrations [ 10 5 cells/ml] are listed in a table for each of the individual intervals.the intervals set in the Cell Diameter Histogram can be saved for future reference. 4.4 Object Diameter Histogram Clicking on the Object Diameter Histogram button will bring up the Object Diameter Histogram. Analogous to the representation of the diameter of the living cells, the diameter of all recognized objects such as cells, debris, air bubbles and viable and dead cell aggregates may be displayed in this histogram depending on whether the information is provided by the image analysis Software. The default image analysis Software (Cell Type: Std. Cells (V5.00)) delivered with the Cedex Analyzer does not provide any detailed information about objects. Therefore, clicking on the Object Diameter Histogram button will result in a message that there is nothing to display, and nothing will be shown in the diagram. D Software 97

133 Graphical Display of the Analysis Results Compactness Histogram 4.5 Compactness Histogram The ratio between the cell circumference and the cell area is based on an ideal sphere (4p), which is equivalent to the value >1< on the abscissa of the Cell Compactness Histogram. The extent of variation between the cell shapes and an ideal sphere is reflected in values being greater than 1. The shape of a cell is known as the Compactness. Click on the Compactness Histogram button to display a diagram that compares viable (!) cell shapes to that of an ideal sphere. If a significant number of cells (ordinate) have a high value, this could indicate improper handling of a sample. The Compact Histogram can be used to check the state of the cell culture (e.g., if the stirring speed is too high or nutrient composition is incorrect). D Figure 88: Compactness Histogram This diagram is based on the compactness of all viable cells in the measurement. To view results of individual cell images, see Result Data Area. 98 Cedex Analyzer Operator s Guide

134 Graphical Display of the Analysis Results Measurement Statistics Histogram 4.6 Measurement Statistics Histogram Click on the Measurement Statistics button to display a column diagram showing the total number of viable cells (green columns) and dead cells (red columns) found in the images analyzed. Figure 89: Measurement Statistics Histogram In the bar diagram, the number of living cells is represented in green bars and the number of dead cells in red bars on top of the green bars. The Combine button, which appears when the Measurement Statistics Histogram is open, can be used to combine several images to give a better overview of the whole sample. Conspicuous bars can thus be immediately identified, and the user can then view and assess the relevant images (see Image Area ). D The results of each individual image can be seen again by clicking on the Single button. If an image has been automatically excluded by the Software or manually excluded by the user, the corresponding position in the diagram will be empty. Software 99

135 Cultivation Time Chart Creating a CTC View 5 Cultivation Time Chart In the Cultivation Time Chart (cultivation progress/result diagram), the growth patterns of cell cultures can be graphically evaluated. It is also possible to export and print out the data. The CTC Views dialog box required for creating a Cultivation Time Chart is opened by clicking on the CTC button in the Shortcuts area of the Cedex Control Center or by selecting the Cultivation Time Chart option in the Measurements menu. In the CTC Views dialog box, charts can be created, viewed, edited, exported and deleted. A collection of data used for the creation of a particular chart is called a View. Each View can have up to 5 separate series of measurements for comparison of data. D 5.1 Creating a CTC View The CTC Views dialog box has two areas (see Figure 90): c The View area is used for viewing, exporting, creating and deleting charts. The Filter By section located at the top of this area is used for finding previously created cultivation time charts. c The Series belonging to selected view area is used for creating, editing, listing or deleting the various measurement series belonging to the View highlighted in the View area. Figure 90: CTC Views dialog box 100 Cedex Analyzer Operator s Guide

136 Cultivation Time Chart Creating a CTC View The View Area This area is used for viewing, exporting, creating or deleting a View. If no filters have been set, all Views that have been created will be displayed under the View Name column. If filters have been set, only those Views that match those filters will appear under this column. To see the chart for a particular View, highlight the row of the desired view and click on the View Chart button. To create a new View, click on the button New. Highlighted rows of Views can also be exported with the Export button or deleted using the Delete button. Previously created views can be searched for using various filter criteria in the Filter By section at the top of the View area. One can filter by name of the View, username of the creator or by the date a View was created or modified. Enter the desired parameters and click on the Find button. When searching by date, the checkbox next to the date must first be checked. After checking the box, clicking on the drop-down menu to the right of the date will open up a calendar in which the desired date can be selected. When the button New is selected, a dialog box will open asking for a name for the new View. A name must be given before a View can be created. Give a name for the new View and click on OK. The new View will appear highlighted in the left-hand section of the View dialog box. It is now possible to select the desired measurements for this View using the Series belonging to selected view area at the bottom half of the CTC Views dialog box The Series of Measurements Belonging to Selected View Area This area is used for creating, editing, viewing and deleting measurement series for a particular View. In order add to or modify specific measurement series for a particular View, that View must be highlighted in the View area. D Software 101

137 Cultivation Time Chart Creating a CTC View Adding Measurements to a View Do the following to find and select measurements for a new View or for a View that has already been created: 1 Highlight the View to be modified in the View area of the CTC Views dialog box and click on the New button on the right-hand side of the Series belonging to the selected view area. This will open the Selection of Data Series dialog box, in which measurements can be selected for the creation of a View (see Figure 91). 2 Choose the desired System name in case measurements from other systems that have been imported into the database should be added to the chart (see Data Exchange ). 3 Choose the Workarea (base directory in which measurement data are stored), the Reactor ID and the preferred Data Set (original or effective measurement data, see Effective Data Sets ). 4 Click on the Find button. All of the Sample IDs associated with that particular Reactor ID will appear in the upper section of the Selection of Data Series dialog box. 5 Click on the empty column to the left of the measurement to be added to the series in order to highlight that measurement. Multiple measurements can be highlighted either by holding down the <Shift> or <Ctrl> key. 6 When all of the desired measurements have been selected, click on the Add selected measurements button. D 7 Click on Save. The Selection of Data Series dialog box will automatically close. The CTC Views dialog box will reappear and show the measurements that have been added to the View in the Series belonging to the selected view area. 8 To add another series to a View, click on the New button again. The Selection of Data Series dialog box will open. Follow Steps 2 7 above to add measurements to the new series. 9 Up to 5 separate series can be added to one View. Once 5 series have been added to a View, the New button will no longer be available for that View. Figure 91: Selection of Data Series dialog box 102 Cedex Analyzer Operator s Guide

138 Cultivation Time Chart Creating a CTC View Editing Measurements in a View Measurements can be added or removed from a particular View by using the Edit button in the Series belonging to the selected view area of the CTC Views dialog box. To edit the measurements found in a View, do the following: 1 Highlight the row of the View to be edited in the View area of the CTC Views dialog box. 2 Highlight the particular series of a View to be edited in the Series belonging to the selected view area. 3 Click on the Edit button. This will open the Selection of Data Series dialog box (see Figure 91). 4 Add or remove measurements from the series list by highlighting the measurements and clicking on the Remove button at the bottom of the dialog box. 5 Click on the Save button. The changes will be saved and the dialog box will automatically close. 6 The CTC Views dialog box will become available and other series in the same View or other Views can now be edited. Measurements can also be excluded from a Cultivation Time Chart without being removed from the series. All measurements selected for a series that are marked with a (4) in the checkbox of the Use column will be displayed in the Cultivation Time Chart. Should it not be desirable to display a particular single measurement, the measurement can be unselected by removing the (4) in the Use column with a mouse click Viewing List of Measurements in a Series If measurements have been added to a View, a simplified list of the series will appear in the left-hand side of the Series belonging to the selected view area of the CTC Views dialog box. To see the full list of all measurements from all series created, click on the List button. This will open the Series List dialog box (see Figure 92). A search for specific measurements in the list can be done using the Filter By area in the upper right-hand corner of the Series List dialog box. Searches can be made by Workarea, Reactor ID or date of measurement. Once the filter parameters have been set, click on the Find button. The measurements that fit the parameters will be displayed in the Measurements area in the lower left-hand corner. Only series that contain measurements with the correct parameters will be displayed in the Series area in the upper left-hand corner of the Series List dialog box. D Figure 92: Series List dialog box Software 103

139 Cultivation Time Chart Creating a Cultivation Time Chart Deleting Views and Series Entire Views can be deleted by highlighting the View and clicking on the Delete button in the View area of the CTC Views dialog box. If one series of a particular View should be deleted, highlight the relevant View in the View area, then highlight the series to be deleted in the Series belonging to the selected view area. Click on the Delete button in the Series belonging to the selected view area of the CTC Views dialog box Exporting a View The series of measurements in a view can be exported via the Export button in the CTC Views dialog box. Select the View to be exported in the View area of the CTC Views dialog box and click on the Export button. An Export dialog box will open in which the desired settings and parameters can be selected (see Export to File ). 5.2 Creating a Cultivation Time Chart Once a View has been created with the desired series of measurements to be used for a chart, the Cultivation Time Chart can be created. To create a Cultivation Time Chart, do the following: 1 Highlight the View to be used for the creation of a Cultivation Time Chart in the CTC Views dialog box. D 2 Click on the View Chart button, this will open the Cultivation Time Chart dialog box (see Figure 93). 3 Select the parameters to be displayed in the chart by clicking on the desired parameters in the Data Selection area in the upper right-hand corner of the dialog box (see The Data Selection Area ). 4 Select the series to be displayed in the Chart area in the lower right-hand corner of the dialog box. 5 A graph will then be generated showing the selected parameters and series. Only measurements already loaded will be displayed in the Cultivation Time Chart diagram. The Selection of Data Series dialog box must be brought up again to add additional measurements. 104 Cedex Analyzer Operator s Guide

140 Cultivation Time Chart Creating a Cultivation Time Chart The Data Selection Area Which curves should be displayed in the diagram is determined in the Data Selection area of the Cultivation Time Chart dialog box. The following values can be selected for display: c Viable Cell Conc.: viable cell concentration[ 10 5 cells/ml] c Total Cell Conc.: total cell concentration [ 10 5 cells/ml] c Viability [%]: percent viability c Total Cell Count: total number of all cells counted c Avg. Compactness: average compactness of living cells [without unit] c Avg. Diameter: average diameter of living cells [µm] c Std. Dev.: the deviation from image to image of the number of cells found in each image c Aggregate Rate [%]: percent of cells found in aggregates c Dead Cell Conc.: dead cell concentration [ 10 5 cells/ml] c Viable Cell Count: the total number of viable cells counted c Dead Cell Count: the total number of dead cells counted c Total Object: the total number of objects counted Click on the appropriate checkboxes to select the desired values. D Figure 93: Cultivation Time Chart dialog box The measurement series, including information about which measurements have been used to create the chart, are listed in the Data Series area in the bottom left-hand corner of the Cultivation Time Chart dialog box. A legend indicating the symbol (form and color) used for each parameter is at the top of the graph. The color used for each series is indicated in the Chart area in the lower right-hand corner of the dialog box. The x-axis units can be displayed as either days [d] or hours [h]. Click on the Time[d] below the x-axis to switch to hours. The x-axis calibration will be automatically recalculated. Software 105

141 Cultivation Time Chart Creating a Cultivation Time Chart If the mouse pointer is placed over a measurement point in the diagram, detailed information, including the date and time of the measurement as well as the results, will be displayed next to the point. Also, the graphic representation can be enlarged or scaled down again with the use of the mouse (see Enlarging the Histograms ) Fitting to the Lowest Common Value The Fit lowest common value button enables automatic shifting of the zero-point of single measurement series to each other. The following can be selected: c Viable Cell Density c Dead Cell Density c Total Cell Density By means of this function, the zero-point of each series will automatically be shifted on the x-axis, in order to be able to better compare the measurement series to each other. The lowest common value of all the measurement series is automatically determined, and the graphs in the diagram are shifted to each other so that the lowest common value falls on the x-axis at the same point. While doing so, the left-most point of the graph of all the measurement points is set at value 0. D Measurement Series Offset In the graph, measurement series are automatically displayed such that all measurement series begin at time 0. The different measurement series can, however, be best compared to each other when the beginning of the exponential growth phase (log phase) starts at the same time. Therefore, it is possible to shift the curves in the diagram by changing the offset for each series. A button in the Offset column of the Data Series area displays the offset set by the user (the button displays 0 [h], if an offset was not set). Clicking on this button opens the Measurement Offset dialog box. The measurement series offset can be then manually shifted in this dialog box. Figure 94: The Measurement Offset dialog box The offset can be separately entered for each of the five measurement series by clicking the button with the corresponding number of the measurement series. Large time differences can be entered in days [d], small ones in hours [h] by clicking on the appropriate buttons [d]/[h]. The offset can be set by selecting the desired series number (colored boxes) and then moving the slider to the desired offset. Using the slider will cause an immediate shift of the measurement series in the diagram so that it can be immediately seen where the best position for a series is in the diagram. The smallest time unit that can be set is 0.10 hours. The OK button confirms the offset values in the graphics. 106 Cedex Analyzer Operator s Guide

142 Cultivation Time Chart Creating a Cultivation Time Chart Variable Axis Calibration The buttons lin and log are used to determine whether the y-axis should display in a linear (lin) or logarithmic (log) scale for cell concentration data. The default value is lin. The x-axis units can be displayed as either days [d] or hours [h]. Click on the Time[d] below the x-axis to switch to hours. The x-axis calibration and division will be automatically adjusted The Exponential Regression Button Using the Exponential Regression button in the View section of the CTC Views dialog box, cell culture growth patterns can be displayed with their Specific Growth Rate [µ] and Doubling Time [T]. The corresponding values appear in the Data Series list (see Figure 95). D Figure 95: The Exponential Regression dialog box Only viable cell concentration will be shown in this graph. The measurement parameters Specific Growth Rate [µ] and Doubling Time [T] of the culture are computed by means of the differential curve. Click on the to close the Exponential Regression dialog box. The CTC Views dialog box will reappear Printing Out a Cultivation Time Chart Cultivation Time Charts can be printed out via the Print button in the Cultivation Time Chart and the Exponential Regression dialog box. To print out a chart, click on the Print button. A dialog box will open in which the printer settings can be selected or the chart can be directly printed. Clicking on the Print button will open a dialog box with a preview of the page to be printed. Software 107

143 General Functions of the System Data Management 6 General Functions of the System The Cedex Control Center offers users with the appropriate rights access to a set of functions in addition to the basic functions of analyzing, modifying and reprocessing samples and measurement results. These functions allow for easy and user-friendly operations with the Cedex Control Center, although some functions are only available to the Administrator (see Administrator Functions ). 6.1 Data Management Printing Reports The main Report menu is located directly on the menu bar of the Cedex Control Center; this menu serves as direct access to the report functionality for all of the different reports. In addition, Print Report buttons are located in all of the appropriate dialog boxes (e.g., Measurement List, Audit Trail, etc.). Pre-configured report templates can be selected for printing reports, and new templates can be created. D The following information can be printed out: c Operational data Allows the user to track a device s operating hours, number of measurements and liquid consumption. c Measurement data Contains information about measurement parameters and calculated results (e.g., sample identification data, name and parameters of the Cell Type used, calculated measurement result data, etc.). Select the desired option for the form in which the result data should be printed via the Name drop-down menu in the Report Template for the measurement report. Options include: c Standard (standard measurement report without details) c Full Details (full report including detailed images, results and histograms) c List (for multiple measurements displayed in a list) c Measurement audit trail (measurement report with audit trail entries) c Multiple long (for multiple measurements printed one after the other) c System configuration parameters Provides a list of system parameters as displayed in the System Options. c Audit trail Provides a statement of all user initiated activities and related data. c Automatic adjustment and alignment verification Presents results from the automatic adjustment of focus and brightness. 108 Cedex Analyzer Operator s Guide

144 General Functions of the System Data Management Export to File Exporting measurement result data is done via the Export to file area of the Measurement List dialog box or via the Export to file option in the Functions menu of the Control Center. Four different formats can be chosen including CSV, XML, Excel-DIF and Flat file. In addition, a sub-set of parameters to be included in the file can be selected. To export measurement results, follow the instructions below: 1 Select the Export to file option in the Functions menu of the Cedex Control Center. The Measurement List dialog box will appear with the Export To File button located at the bottom of the dialog box. 2 Select a single measurement from the list by clicking on the field to the left of the desired line. To choose a set of measurements, hold down the <Ctrl> button while selecting the appropriate lines. Alternatively, the desired measurements can be searched for using different filter criteria (see Searching for Measurements ). 3 Click on the Export To File button. The Export dialog box opens: Figure 96: The Export dialog box 4 In the Export dialog box, individual Parameter and String delimiters can be defined (this only applies to CSV and Flat files). D 5 In the Location area, the target path to be used for storage of the export file is entered. The button on the right of the entry field opens a dialog box in which the path can be directly selected. The name of the file will be automatically generated. 6 To specify a sub-set of parameters to be exported, either click the checkboxes beside the preset options (i.e., All Parameters, Cell Data and Overall Results) or select the desired parameters from the Columns to Export area. To choose a set of parameters, keep the <Ctrl> button pressed while making selections. The preset options are: c All Parameters: All parameters about the measurement. c Cell Data: Data for each and every cell detected in the measurement. c Overall Results: Results such as average cell diameter, %viability, total cell concentration, viable cell concentration, etc. 7 In the File format area, select the file format by clicking on the appropriate checkboxes. The files will automatically and unchangeably receive DIF or CSV file name extensions. The file format Excel-DIF should always be chosen if a file is to be exported into Excel. 8 Click on the Export Selected Data button. 9 A message dialog box will appear to confirm successful export of information. Click on OK. The measurement data can then be viewed in the file created. Software 109

145 General Functions of the System Data Exchange 6.2 Data Exchange The Data Exchange function allows for the exchange of a complete measurement package, including all data and images, between different Cedex Software databases (DBs). The user can export selected measurements from one Cedex Software database and import them into another database. This enables the user to view a measurement performed on one system within the context of the Cedex Software on a completely different system and Control Unit. Measurement data cannot be exported from a DB and then re-imported back into the same DB. The Archive/ Restore function must be used when the intention is to move measurement data to an external storage media for possible future restoring to the original DB from which it was moved. See Archiving Data, for more information about archiving measurements Export In order to exchange measurement data between Cedex Systems, the data first needs to be exported from the system on which it was created to external storage. To export complete measurement packages, including data and images, proceed as follows: D 1 Select the Data Exchange option in the Functions menu of the Cedex Control Center, and choose the option Export. A Measurement List dialog box appears with an EXPORT TO DB button located at the bottom of the dialog box: Figure 97 2 Select a single measurement from the list by clicking on the field to the left of the appropriate line, or choose a set of measurements by holding down the <Ctrl> button and selecting the appropriate lines. Alternatively, search for the desired measurements using filter criteria. 3 Click on the EXPORT TO DB button to open the Export dialog box: Figure 98 ccc 110 Cedex Analyzer Operator s Guide

146 General Functions of the System Data Exchange 4 Enter the path under which the exported measurements should be stored in the Location area. Alternatively, the button on the right of the entry field opens Windows Explorer in which the path for the exported measurement package can be directly selected. Select the preferred path for the measurements and click on OK. The Export dialog box reappears. 5 Click on the Export button to start the exporting process. A message appears as soon as export has been successfully completed. Confirm the message by clicking on OK. 6 Click on to close the Export dialog box. 7 Three files are generated for each exported measurement package and stored in the selected location: c CX2 file c SIG file c Text document Figure 99 All three files are required for importing the measurement package into a different Cedex System DB. Ensure that all three files are always stored in the same location to enable importing of measurement packages in the future. A default entry for the path under which the export file should be stored can be entered in the System Options under the Setup menu. Open the Data Exchange tab and look for the ExportPath parameter. In the Value column, enter the default path (see list of User Preferences and System Options in the Appendix). The following message may appear after selecting the measurements to be exported and clicking on the Export button: D Figure 100 If this message appears, click on Yes to confirm the message and install the certificate. The export will continue after confirming the installation of the certificate. Software 111

147 General Functions of the System Data Exchange Import Once the measurement package has been exported from one system to external storage, the data can then be imported to another database. To import the measurement package into a different Cedex Software database, follow the instructions below: 1 Ensure that these three files generated when the measurement package was exported are placed in the same folder (see Export ): c CX2 file c SIG file c Text document 2 Select the Data Exchange option in the Functions menu on the Cedex Control Center and choose the option Import. The Import from external DB dialog box appears, with ADD and REMOVE buttons located on the righthand side of the dialog box: D Figure Click on the ADD button; an Open archive files(s) dialog box opens in which measurements to be imported are selected. 4 Navigate to the folder where the exported measurement files are stored: Figure 102 Only the CX2 file is shown in the Open archive files(s) dialog box. The SIG and text file must be in the same location in order for the measurement package to be successfully imported, but these two files are not visible in the Open archive files(s) dialog box. 5 Select the measurements to be imported, and click on Open. The Import from external DB dialog box reappears showing the measurement selected for importing and with the IMPORT button activated: Figure 103 ccc 112 Cedex Analyzer Operator s Guide

148 General Functions of the System Viewing and Evaluating the Audit Trail File 6 To import further measurements located in other folders, click on the ADD button, and select the measurements via the Open archive files(s) dialog box, as described in Steps 4 and 5. 7 Once you have selected all measurements to be imported, click on the IMPORT button to start the import process. A message appears when the import is successfully completed. Click on OK. 8 Click on to close the Import From External DB dialog box. It is not possible to import more than 200 measurements at one time. A default entry for the path under which the import file should be stored can be entered in the System Options under the Setup menu. Open the Data Exchange tab and look for the ImportPath parameter. In the Value column, enter the default path (refer to list of User Preferences and System Options in the Appendix). To view imported measurements that come from a different system and, consequently, have a different System ID, select the appropriate System ID for those measurements in the SystemName drop-down menu in the Measurement List dialog box. 6.3 Viewing and Evaluating the Audit Trail File The Cedex Analyzer Software automatically creates an Audit Trail (log) file for each sample and records all relevant hardware information relating to the sample. The Audit Trail file data can never be overwritten. This ensures that all recorded, analyzed and modified measurement data is documented (see The System Audit Trail File ). D Software 113

149 General Functions of the System User Preferences 6.4 User Preferences The User Preferences dialog box is located under the Master Data drop-down file menu in the Cedex Control Center (see Figure 104). Figure 104: User Preferences dialog box with the tab Measurement List Default Filter selected D A logged-in user with specific access rights to the User Preferences option can set preferences for a number of elements, including the result parameters to be displayed in the Multi Run result list and Measurement List dialog box and default measurement parameters for carrying out measurements Adjusting Result Display in the Measurement List and Multi Run Dialog Boxes The result data to be displayed in the Measurement List dialog box, as well as the result list area of the Multi Run dialog box, can be adjusted in the User Preferences dialog box. The numbers in the entry ResultsToShowInList located under the Measurement List Default Filter tab indicate which types of results will be displayed in the Measurement List. The numbers in the entry DisplayedResultTypes under the General tab indicate which types of results will be displayed in the result list of the Multi Run dialog box as follows: c 1: Avg Diameter c 5: Avg Compactness c 6: Viable Cell Count c 7: Dead Cell Count c 8: Total Object Count c 9: % Viability c 10: Viable Cell Conc. c 11: Dead Cell Conc. c 12: Total Cell Conc. c 13: Std. Deviation c 14: Total Cell Count c 15: % Aggregate Rate The default entry for these fields is 12, 10, 9, which corresponds to Total Cell Conc., Viable Cell Conc. and % Viability, respectively. The order in which the numbers are listed is the order in which the results will appear in the lists. To add more results to be displayed, enter the number that corresponds to the desired result parameter in the fields. Numbers must be separated by a comma with no space in between. 114 Cedex Analyzer Operator s Guide

150 General Functions of the System User Preferences Specifying Default Measurement Parameters The logged-in user with specific access rights to the User Preferences option in the Master Data menu, can determine the preferred default values for certain measurement parameters (Cell Type, dilution, etc.). The default parameter settings are only valid for this user. Follow the instructions below to change the default values for certain measurement parameters: 1 Select User Preferences in the Master Data menu of the Cedex Control Center. This will open the User Preferences dialog box. 2 Select the Measurement tab in the User Preferences dialog box. 3 Manually type in the appropriate default measurement parameters in the Value column. The defaults for the following parameters can be determined: c CellType c DefaultCombinedNumber (for the Measurement Statistics Histogram) c MeasurementPrecision c ReactorID c SampleInitialDilution c SampleVolume c Workarea 4 Put a checkmark in the checkbox of the Save Last column if the last value used for a measurement should be used as the default for the next measurement. 5 Click on Save to confirm. 6 Close the dialog box. The new default parameters will apply to new measurements. D Specifying Other Default Parameters Other default parameters can be specified for the Measurement List dialog box, the CTC Views dialog box and the Audit Trail. Select the following tabs to create or alter default parameters: c Measurement Default Filter: Create or alter default parameters for filter settings in the Measurement List dialog box. c CTC Views Default Filter: Create or alter default parameters for the filter settings in the CTC Views dialog box. c Audit Trail Default Filter: Create or alter default parameters for the filter settings in the Audit Trail dialog box. Software 115

151 General Functions of the System Changing Own Password Specifying the Workarea for the Analysis Data The analysis results are stored in the workarea that is selected in the Measurement dialog box before a measurement is run. If analysis results from a specific workarea are to be viewed, the appropriate workarea needs to be chosen from the drop-down list in the Measurement List dialog box. The user can only choose a workarea from the list of workareas to which she/he has been assigned. Only the Administrator has the right to assign workareas (see Administration of User Accounts ). 6.5 Changing Own Password Users may change their own passwords. Follow the instructions below: 1 Click on the System menu on the Cedex Control Center. 2 Click on Change my Password; the Change password area will appear. 3 Enter your present password in the first field. D 4 Enter your new password in the second and third fields. 5 Click on OK to confirm the entry, and a message will confirm the entry. 6 Click on OK to shut the dialog box. 116 Cedex Analyzer Operator s Guide

152 Administrator Functions Administration of User Accounts 7 Administrator Functions The following system functions are generally only available to the Administrator and/or Superuser: c Administration of user accounts c Password management and assigning workareas c Adjustment of the image analysis c Securing data 7.1 Administration of User Accounts The user usually has limited access rights. All administration rights relating to user accounts(i.e., creating, deleting, modifying and delegating rights), should remain exclusively with the Administrator. All administration of user accounts and rights management is done in the User Rights Management area. To open the User Rights Management area, click on the Setup menu in the Cedex Control Center and select User and Rights Management. The User Rights Management dialog box is structured with menus and sub-menus similar to the directories in Windows Explorer (see Figure 105). The distinction between functions, roles, users and groups, which is mainly connected to the delegation of rights, is explained in the appropriate sections of this chapter. Password settings can also be configured in this area. D Creating User Accounts Before creating new user accounts, the password configurations should be set up (see Password Management ). Follow the instructions below to create a user account: 1 Click on the Setup menu in the Cedex Control Center. 2 Click on User and Rights Management; the User Rights Management dialog box will appear. 3 Right click on the All Users folder and click on Create new user. The User account area will appear. 4 Enter the user s first name and last name in the first and second rows and a username for the account in the third row. 5 Enter a temporary password for this user account in the fourth field. Click on Save to confirm. If the option, must change on first login is selected, the user will be forced to change the password the first time he or she logs into the Cedex Control Center. 6 Restart the Cedex Software application. A user is only authorized to carry out measurements after he has been assigned at least one work area. Software 117

153 Administrator Functions Administration of User Accounts Assigning Access Rights The user is normally denied access rights to certain areas, for example administration of user accounts and sensitive system functions (focus adjustment, creating SST-Checkpoints, etc.). The user, therefore, cannot access all of the menus on the Cedex Control Center after login. Access rights can be modified at any time by the Administrator. Rights are generalized in user roles that can comprise a single access right or a set of access rights. To grant rights, you will need to assign one or more user roles to a user. The following user roles are available after installation of the Software: c Administrator c Production Staff c Research Staff c Superuser c Support By default, the pre-installed Production Staff, Research Staff and Support roles have no functions assigned to them. More detailed information about creating functions for each pre-set user role, as well as editing existing functions and creating new user roles, can be found under Creating and Editing User roles. D Follow the instructions below to assign rights to a user account: 1 Click on the Setup menu in the Cedex Control Center. 2 Click on User and Rights Management, and the User Rights Management dialog box will appear. 3 In the All Users main menu, open the user account menu that is to be modified. A User Role sub-menu will appear. 4 Open the All Roles main menu and drag the appropriate user role from the All Roles menu into the All Users sub-menu. The access rights available for this user role will be added to the account. To deny certain access rights, the corresponding user role needs to be deleted from the All Users sub-menu. Right click the user role which is to be deleted and click on Remove the role from the user. Figure 105: User Rights Management dialog box 118 Cedex Analyzer Operator s Guide

154 Administrator Functions Administration of User Accounts Creating User Groups It is possible to generalize one or more user accounts in user groups. Instead of assigning rights to a single user, a user role or a set of user roles can be assigned to a user group. The whole user group, therefore, receives all access rights that have been assigned to the user roles. To create a user group and add user accounts, proceed as follows: 1 In the User Rights Management area, right click on the User Groups main menu and click on Create new user group. 2 A name for the new group can be entered in the User Group dialog box. 3 Click on OK to add user group to User Groups list. 4 Open the All Users main menu and drag from it the desired user account into the appropriate user group sub-menu. The user is added to the user group and receives all access rights assigned to this group. A user can be added to one or more user groups Editing and Deleting User Accounts The first name, last name and username of a user account can be edited if, for example, an existing user is to be replaced by a new user with identical access rights. A user account can also be deleted in the editing area. Proceed as follows to edit a user account: 1 Click on User and Rights Management, and the User Rights Management dialog box will appear. D 2 Open the All Users main menu and right click the user account menu to be edited. 3 Click on Edit the user and the User Account dialog box will appear. The name, last name, username, password and priority can be changed. 4 Click on the Deleted checkbox if the user account is to be deleted. 5 Click on Save to store the changes. In order to avoid confusion, the Software will not allow for the creation of a new user with the same user name as a user name that has been deleted. Measurements that have been run under a user name that has been deleted are still available for viewing. Software 119

155 Administrator Functions Administration of User Accounts Creating and Editing User Roles Rights are generalized in user roles that comprise a single access right or a set of access rights. In the User Rights Management area, access rights are called functions. It is necessary to determine the different responsibilities for the different roles and, therefore, functions they should have access to. D Five standard user roles are pre-installed by the Software. All of the roles are suggested roles that could be used for setting up specific distribution of access rights: c Administrator: The Administrator is allowed to use all administrative functions of the system. He is not allowed to use any operational functions. c Production Staff: It is intended for members of the Production Staff who are only allowed to use specific operational functions depending on company policies (i.e., execute measurements, execute an SST, change consumables). c Research Staff: Members of the Research Staff who could be allowed to use all operational functions of the system. c Superuser: The Superuser is allowed to use all operational functions of the system mainly for maintenance purposes. c Support: Support of the Cedex System by Roche Technical Service requires access to all operational functions similar to the Superuser role. Access to the System Options should be restricted to the Administrator, Superuser and Support. All options necessary for a user to modify his workplace according to his needs can be found under User Preferences. Only selected users should be authorized to edit SST-Checkpoints. See Creating SST Checkpoints for further information. Follow the instructions below to create a new user role: 1 In the User Rights Management dialog box, right click on the All Roles main menu and then click on Create new role. 2 A name for the new role can be entered in the Role dialog box. 3 Click on OK to add the new user role to the All Roles list. To add rights to or delete rights from an existing user role, proceed as follows: 1 Open the user role menu that is to be modified in the All Roles main menu. A Role Functions sub-menu will appear. 2 Open the All Functions main menu and drag from it the desired functions into the Role Functions sub-menu. These functions will be added to the user role. To delete certain functions from the User Role sub-menu, right click on the desired function and select Remove the function from the role. 120 Cedex Analyzer Operator s Guide

156 Administrator Functions Password Management 7.2 Password Management The Cedex Software has been equipped with a detailed password management that is compliant with CFR 21 Part 11 guidelines Specifying Password Characteristics Password settings can be specified and changed in the User Rights Management dialog box. The following password settings can be configured: Composition rules Min characters/min digits Min length/max length Attempts to login Minimum requirements for the number of characters and digits used. Minimum and maximum length of the password. Number of times wrong passwords can be entered consecutively before this user is denied access. Only the Administrator can reverse denial of access by issuing a new password. The user will be warned before the last allowed attempt. Password never expires expires in Warn the user Old password can be reused after Use blacklist Passwords never lose their validity. Number of days after which passwords lose validity. Number of days before password expiration to warn the user. Number of new passwords that must be used before old password can be reused. The so-called BlackList can be used to restrict selection of passwords to only those that fulfill a specific security standard. This list contains passwords that are not allowed to be used. The list is empty after installation of the Software by default. D The Administrator can enter incorrect passwords without limits with an extended time period after each retry Assigning New Passwords Follow the instructions below: 1 Click on User and Rights Management, and the User Rights Management dialog box will appear. 2 Open the All Users main menu and right click on the user account menu that is to be edited. 3 Click on Edit the user and the User Account dialog box will appear. 4 Enter new password in the corresponding line (Password). 5 Click on Save to store the change. Software 121

157 Administrator Functions Assigning Work Areas 7.3 Assigning Work Areas The analysis results from a measurement are organized in work areas. A user needs to be assigned to at least one work area to be able to run a measurement, otherwise an error message will appear. All measurement data produced by this user will be saved in the work area selected during execution of measurements. The user can only work with measurement data from work areas to which he has been assigned. New work areas can be created and assigned to one or more users via the User Rights Management area. Follow the instructions below to create and delegate work areas: 1 Click on the Setup menu on the Cedex Control Center. 2 Click on User and Rights Management. The User Rights Management dialog box will appear. 3 In the All Users main menu, open the user account menu that is to be assigned the work area. A User Workareas sub-menu will become available. 4 Open the All Workareas main menu and drag the desired work area into the User Workareas sub-menu. This work area will be added to the user account. D To later deny access to a work area, follow the instructions below: 1 Open the User Workareas sub-menu in the user account that is to be modified. 2 Right click on the work area that is to be removed and click on Remove the workarea from the user. 122 Cedex Analyzer Operator s Guide

158 Administrator Functions The System Options 7.4 The System Options The System Options dialog box, in which system parameters are configured, is located in the Setup menu on the Cedex Control Center. Only those users who have been given access to the System Options function, for example, the Superuser and Support, can change system parameters. Setting system parameters includes several changes and modifications, some of which are explained in detail in the sections below. The parameters are organized based on the application areas that are affected (e.g., Measurement, Hardware, Data Exchange). See System Options and User Preferences in the Appendix for a detailed description of all of the System Options. The Cedex Software may need to be restarted in order for changes in the Systems Options to take effect. All elements in the System Options that have not been explicitly described in this Operator s Guide must not be changed without prior arrangement with Roche Diagnostics. In all cases, contact must be made with the local Roche Technical Service before any such changes are made. Access to the Systems Options should be restricted to only the users who are responsible for maintenance of the system! Changing default values in the Systems Options dialog box can have an adverse effect on the system and measurement results Automatically Start the Hardware Management If the AutomaticallyStartHardware parameter is active (entry 1 in the Value column), the hardware management will automatically be initialized when the Software is started. To turn off this function, set the value to 0 in the Value column. D Modifying the Standard Setting for the Multi Sampler DefaultCup The default setting for the Multi Sampler DefaultCup (Cedex Sample Cup position used for Prime, LM ShutDown, focus calibration and all cleaning routines) is position 1 on the Multi Sample Tray. The default position can be changed to any other position. To change the position for the DefaultCup location, do the following: 1 Open the System Options dialog box and click on the General tab. 2 Look for the parameter DefaultCupPosition. The number entered in the Value column will determine the position for the DefaultCup on the Multi Sample Tray. 3 Click on Save to confirm the change. The position chosen for the Multi Sampler DefaultCup does not influence measurements. All 20 positions on the Multi Sample Tray can be used for measurements. Should a sample be present in the DefaultCup position during Prime, LM ShutDown, calibration or any cleaning routines, it can no longer be used for measurements. Software 123

159 Administrator Functions The System Options Turning Off Automatic Incrementation of Sample Cup Position In the case of single measurements run via the Measurement dialog box on a Cedex Analyzer with a Multi Sampler attached, the Software will automatically incrementally increase the sample cup position number with each new measurement. To switch off this feature, do the following: 1 Open the Systems Options dialog box and click on the Measurement tab. 2 Look for the parameter SuggestNextCupPosition. 3 Select 0 from the drop-down menu to turn off the feature. 4 Click on Save to confirm the change. When 0 has been selected, the suggested cup position will always be the same Error Level Displayed to Users D Errors in the Software and hardware will be displayed to the user in the form of an error message. The level of error that will result in the display of an error message depends on the setting of the parameter ErrorLevelDisplayToUser in the General tab of the Systems Options dialog box. The following levels are available: c Level 1 (Fatal): fatal error, system/hardware crash. c Level 2 (Critical): Error as a result of invalid measurement. c Level 3 (Error): Error, but the result does not cause an invalid measurement. c Level 4 (Warning): Information for user. If, for example, the ErrorLevelDisplayToUser is set at Level 1, only error messages regarding system or hardware crashes will be displayed to users. The factory-installed default for the ErrorLevelDisplayToUser is set at Level 3 (Error) Liquid Container Configuration In the Liquid Container Configuration area, the minimum and maximum liquid levels for reagent and waste containers can be set. To open the Liquid Container Configuration dialog box proceed as follows: 1 Click on the Master Data menu on the Cedex Control Center. 2 Click on Liquid Container Configuration and the dialog box will appear. Maximum and minimum volumes can be defined using this dialog box. When standard sized containers are used, it is not advisable to change default settings for the Min volume and Max volume. It is also possible to define a Warn Level and a Lock Level. The standard default for the Warn Level is 6. This means that a warning message will appear if the amount of reagents left is 6 ml or less. The standard setting for the Lock Level is 3, which means that the system will be locked (i.e., no further measurements will be possible) if there are only 3 ml left. The settings for the Warn Level and Lock Level can be changed. Saving changes will immediately update the estimation of the number of remaining measurements. 124 Cedex Analyzer Operator s Guide

160 Administrator Functions Adjustment of the Image Analysis Using the Live Operator Disabling the Reagent Control The Reagent Control function keeps track of the amount of reagents used and notifies the user when the levels are running low. The function can be disabled in the General tab of the System Options dialog box. The Reagent Control function is enabled when the value for the DisableReagentControl entry is set to 0. To disable the function, set the value to Default Settings In general, Research or Production Staff users should not be assigned access rights to the System Options dialog box in which default settings that apply to the whole system can be configured. However, some parameters needed to customize the individual workplace (e.g., definition of the default settings for certain measurement parameters) can be found under User Preferences (see User Preferences ). 7.5 Adjustment of the Image Analysis Using the Live Operator The Cell Type (operator) selected for a measurement takes care of the image evaluation. Roche has put in one pre-setting: c Std. Cells (V5.00) for normal-sized cells with a diameter of about 12 µm (e.g., HB58). Individual adjustments of the operator can be helpful or necessary for cell cultures that, for instance, have an unusual optical appearance or for a counting strategy that deviates from the Cedex Analyzer (e.g., counting aggregates differently). D Adjustment of the operator is referred to as creating a new Cell Type. A new Cell Type can be created or an already existing Cell Type can be re-adjusted. This can be done with the help of eight parameters that influence the way in which an image is evaluated. Each of these parameters directly influences the image processing strategy and, hence, the measurement results. In the available Software version, an algorithm with the pre-setting mentioned above is available. The parameters of the factory installed pre-setting are overwritable. For data safety reasons the parameters of the factory installed pre-setting should not be altered. Since original settings are overwritable, caution should be advised for all authorized users Description of the Cell Type List and Live Operator The Live Operator dialog box, in which Cell Types can be created and modified, is accessed in two ways: c Via the Measurement dialog box in the View mode. c Via the Cell Type List option in the Master Data menu on the Cedex Control Center. Software 125

161 Administrator Functions Adjustment of the Image Analysis Using the Live Operator The Cell Type List Dialog Box To open the Live Operator dialog box directly from the Measurement dialog box when it is in the View mode, click on the Live Operator button located in the middle of the Measurement dialog box. When the Cell Type List option in the Master Data menu is selected, the Cell Type List dialog box will open (see Figure 106). There are several options in this dialog box including: c New: Create new Cell Types c Edit: Modify existing Cell Types c View: View existing Cell Types c Delete: Delete existing Cell Types c Live Operator: Open the Live Operator dialog box D Figure 106: Cell Type List dialog box 126 Cedex Analyzer Operator s Guide

162 Administrator Functions Adjustment of the Image Analysis Using the Live Operator Creating a New Cell Type A new Cell Type must be created and saved via the Cell Type dialog box before the Live Operator dialog box can be opened for modification of that Cell Type. A new Cell Type can be created by following the instructions below: 1 Open the Cell Type List dialog box. Highlight the existing Cell Type upon which the new Cell Type should be based. 2 Click on the New button. A message will appear asking if the new Cell Type should be based on the highlighted Cell Type in the list. Click on Yes. The Cell Type dialog box will open (see Figure 106). The Live Operator button will be inactive at this time. 3 Fill in the information for: c The name of the new Cell Type c Sample preparation procedure (Std. is currently the only option) c Focus Offset: the offset from the ideal focus point. The Focus Offset should be set to 0 to ensure best results for cell count and determination of viability. Please consult local Roche Technical Service before using any other number for the Focus Offset as selecting another value for this parameter may lead to poor results. Note that the Sedimentation Duration does not apply to the Cedex Standard Analyzer. Make sure that the IR Operator is set to CXStdImageOperator. 4 Click on the Save button. The Cell Type dialog box will automatically close. The Cell Type List dialog box will be active again and include the just-created Cell Type in the list. 5 Highlight the row of the new Cell Type and click on the Edit button. The Cell Type dialog box will reopen and the Live Operator button will be active. 6 Click on the Live Operator button and the Live Operator dialog box will open (see Figure 108). D 7 In the Data Source area, select the Work Area, followed by the Reactor ID, Sample ID and Data Set of the measurement for which the image analysis should be improved. The parameters for the loaded measurement are preset. 8 Select an image of the measurement in the Image ID section. This image will be loaded and displayed in the dialog box in the upper right-hand corner, with the living cells marked with a green circle and the dead cells marked with a red circle. 9 Make the desired modifications on a single parameter first. As soon as a parameter has been modified, reprocessing of the data is automatic (see Description of the Individual Operator Parameters ). The image display then shows the reprocessed image (see Working with the Live Operator ). 10 When an optimized adjustment of the Operator parameters has been found, click on Save to confirm the modification for the new Cell Type. When Cancel is clicked on, the Live Operator dialog box will close without saving the changes. Software 127

163 Administrator Functions Adjustment of the Image Analysis Using the Live Operator Editing an Existing Cell Type An existing Cell Type can be modified. However, it is NOT advisable for data safety reasons to modify an existing Cell Type that has been used for measurements. A new Cell Type based on an existing Cell Type should be created instead. Follow the instructions below to modify an existing Cell Type (not advisable!): 1 Select the Cell Type to be edited from the list of Cell Types at the top of the Cell Type List dialog box and then click on the Edit button. The Cell Type dialog box will open. 2 Modify the following information if desired: c The name of the Cell Type c Sample preparation procedure (Std. is currently the only option) c Focus Offset 3 Make sure that the IR Operator is set to CXStdImageOperator. D 4 Click on the Live Operator button in order to modify other parameters within the Live Operator dialog box for that Cell Type (see Working with the Live Operator ). 5 In the Data Source area, select the Work Area, followed by the Reactor ID, Sample ID and Data Set of the measurement for which the image analysis should be improved. The parameters for the loaded measurement are preset. 6 Select an image of the measurement in the Image ID section. This image will be loaded and displayed in the dialog box in the upper right-hand corner with the living cells marked with a green circle and the dead cells marked with a red circle. 7 Make the desired modifications on a single parameter first (see Description of the Individual Operator Parameters ). As soon as a parameter has been modified, data reprocessing is automatic. The image display then shows the reprocessed image. 8 When an optimized adjustment of the Operator parameters has been found, click on Save to confirm the modifications. 9 Click on Cancel to close the dialog box without saving any changes Viewing an Existing Cell Type Select the Cell Type to be viewed from the list of Cell Types at the top of the Cell Type List dialog box and then click on the View button. The Cell Type dialog box will open in which the information for focus point (Focus Offset) and sedimentation time (Sedimentation Duration) can be viewed. Click on the Live Operator button in order to view other parameters within the Live Operator dialog box for that Cell Type (see Description of the Individual Operator Parameters ). 128 Cedex Analyzer Operator s Guide

164 Administrator Functions Adjustment of the Image Analysis Using the Live Operator Deleting an Existing Cell Type Select the Cell Type to be deleted from the list of Cell Types at the top of the Cell Type List dialog box and then click on the Delete button. A confirmation box will appear, asking the user if he/she wants to delete the Cell Type. If confirmed, the Cell Type will be deleted and disappear from the list. All parameters of the measurements are logged. Deleted Cell Types have no influence on future measurements, but the parameters of deleted Cell Types used for past measurements will still appear in the printed reports of those measurements. D Figure 107: Cell Type dialog box Working with the Live Operator The Live Operator dialog box can be opened via the Cell Type List dialog box, the Cell Type dialog box and the Measurement dialog box. If the Live Operator button in a Measurement dialog box containing specific results is clicked on, the Live Operator will open with the images of that measurement already loaded. If the Live Operator is opened via the Cell Type or Cell Type List dialog boxes, the first measurement in the Measurement List will be loaded. In the Live Operator dialog box, some of the 8 parameters can be displayed on the screen at the same time. Parameters at first not visible can be scrolled into view using the scroll bar under the Operator Parameter display. The table below displays the positions and settings of the 8 Operator parameters. See also Description of the Individual Operator Parameters for a detailed description of each parameter. Software 129

165 Administrator Functions Adjustment of the Image Analysis Using the Live Operator Identifier Minimum Maximum Std. Cells (V5.00) LivingAppearance DeadSize DeadAppearance DeadAggregateMin DeadAggregateMax DeadAggregateApp BorderWidth MinPollutionArea Table 1: A list of the Operator parameters After loading a measurement (Reactor ID and Sample ID) and selecting an image, the selected image is displayed in the upper right-hand corner of the Live Operator dialog box. Each single cell detected by the Cedex Analyzer is marked as dead (red circle) or living (green circle). D Figure 108: Setting parameters for Cell Type Standard Cells 130 Cedex Analyzer Operator s Guide

166 Administrator Functions Adjustment of the Image Analysis Using the Live Operator In the Process Data area, the values for new and previous results are displayed for viable cells (the number of living cells of the current image), dead cells (the number of dead cells of the current image) and %viability. If an Operator parameter is modified, the newest values will appear under New column when an automatic reprocessing of the selected image is finished. The values of the previous processing are displayed under Previous column. Thus, direct comparison to each previous evaluation is possible. The labeling of the cells can be switched on and off in the upper right-hand corner in order to allow for better evaluation of the results from changes in parameter settings. If multiple parameter changes should be made at the same time, remove the checkmark in the Automatic process box by clicking on it. When the checkmark is removed, the button Process now becomes active. Make all changes, then click on the Process now button for an analysis based on the new parameter settings Description of the Individual Operator Parameters LivingAppearance (Living Cells Appearance) Range: [-20, 20], Default: 0, Unit: [absolute measure]. This parameter influences the recognition of living cells. When the value of this parameter is set high, contrastweak objects are also counted as living cells provided they additionally fulfill the size criterion. The lower this value is set, the more contrast an object must have for it to be counted as a viable cell. If the value is changed to positive, shadowy and greyish objects are increasingly counted as living cells. Such a change is sensible if, for example, the optical image shows little contrast due to the structure of the medium or of the cells in the medium. D In standard situations, a change of this parameter can result in the labeling of debris as cells! DeadSize (Dead Cells Size) Range [40, 250], Default 110, Unit [µm²]. Defines the minimum cross-sectional area of a particle in µm². Increasing this value means that fewer particles will be recognized as dead cells. DeadAppearance (Dead Cells Appearance) Range [-10, 10], Default 0, Unit [absolute measure]. This parameter influences the recognition of dead cells. If the value is set high, contrast-weak objects are also counted as dead cells as long as they additionally fulfill the size criterion. The lower this value is set, the sharper the contrast an object must have in order to be counted as a dead cell. DeadAggregateApp (Dead Cells Aggregate Appearance) Range [-10, 10], Default 0, Unit [absolute measure]. Defines the automatic evaluation of a dead cell aggregate (cluster).the cross-sectional area of dead cell aggregates are automatically partitioned into single cells. Increasing this value means that there are more single cells determined in the aggregate. Software 131

167 Administrator Functions Adjustment of the Image Analysis Using the Live Operator DeadAggregateMax (Dead Cells Aggregate Maximum) Range [1500, 5000], Default 2250, Unit [µm²]. Defines the maximum cross-sectional area of a dead cell aggregate (cluster). The dead cell aggregate area within this range is automatically partitioned into single cells. Any aggregate larger than the specified maximum area is not taken into account. DeadAggregateMin (Dead Cells Aggregate Minimum) Range [250, 1500], Default 360, Unit [µm²]. Defines the minimum cross-sectional area of a dead cell aggregate (cluster). When this size is reached, it is then automatically partitioned into single cells. MinPollutionArea (Minimum Pollution Area) Range [5000, 30000], Default 5400, Unit [µm²]. Defines the minimum cross-sectional area of the pollution size (e.g., debris particles, air bubbles, etc). Any pollution size larger than the specified minimum area results in the entire image being excluded. D BorderWidth [µm] Range: [0, 20], Default: 7, Unit: [pixels]. The border frame around the image not used for evaluation. The Borderwidth should not be adjusted in general. Consult with Roche Technical Service before making any adjustments to this parameter. The use of the sliders, especially in combination, can lead to unexpected results. 132 Cedex Analyzer Operator s Guide

168 Administrator Functions Archiving Data 7.6 Archiving Data The objective of the archive function is to secure measurement for future reference data by exporting it to external storage media. Measurement data must be secured at regular intervals and thereafter deleted from the Measurement List in order to ensure enough storage capacity on the Cedex Control Unit. All data from a single or a set of measurements, or optionally only the images, can be deleted from the database once the measurement or measurements have been archived. Archiving should only be carried out by the Administrator and selected users. Measurement data can later be restored from the archive, but restoring the data is only possible using the Cedex System database from which the data has been archived. Measurement data cannot be archived from one Cedex Software database and restored to a different Cedex Software database. The Data Exchange (Import/Export) function must be used when the intention is to import measurement data into a different database. See Data Exchange for more information about the Data Exchange function. All data should also be backed up on a regular basis. Archiving does not replace a back-up strategy. Back-ups of the database should be carried out on a regular basis. See Backing up the Database for more information Archive To archive measurement data, proceed as follows: 1 Open the Functions menu in the Cedex Control Center and select the Archive function found within the Archiving menu. A Measurement List dialog box appears with an ARCHIVE button at the bottom of the dialog box: D Figure Select a single measurement from the list by clicking on the field on the left of the appropriate line, or choose a set of measurements by holding down the <Ctrl> button and selecting the appropriate lines. Alternatively, search for desired measurements using filter criteria. ccc Software 133

169 Administrator Functions Archiving Data 3 After measurements have been selected, click on the ARCHIVE button. The Archive dialog box opens: Figure Enter the path under which the archive files should be stored in the Location area. Alternatively, the button on the right of the entry field opens Windows Explorer in which the path can be selected directly. 5 Click on Save. The Archive dialog box reappears. D 6 (Optional) If desired, choose one of the following options in the Archive dialog box: c Delete records: selecting this option results in measurements, including all respective images, being simultaneously archived to the selected target location and deleted entirely from the local Cedex Software database. c Delete only images: selecting this option results in the selected measurements, including all respective images, being simultaneously archived to the selected target location while images only are deleted from the local Cedex Software database. If no checkmark is placed in either box, measurements will be archived and simultaneously retained in the local Cedex Software database. 7 Click on the Archive button to start the archiving process. A message appears as soon as archiving of information is completed successfully. Click on OK. 8 Click on to close the Archive dialog box. 9 Three files are generated for each archived measurement package and stored in the selected location: c CX2 file c SIG file c Text document Figure 111 All three files are required for restoring the measurement package back into the Cedex Software DB. Ensure that all three files are always stored in the same location to enable restoring of measurement packages in the future. A default entry for the path under which the archive file should be stored can be entered in the System Options dialog box under the Setup menu. Open the Data Exchange tab in the Systems Options dialog box and look for the ArchivePath parameter. In the Value column, enter the default path. The following message may appear after selecting the measurements to be archived and clicking on the Archive button: Figure 112 If this message appears, click on Yes to confirm the message and install the certificate. The archive will continue after confirming the installation of the certificate. 134 Cedex Analyzer Operator s Guide

170 Administrator Functions Archiving Data Restore To restore measurement data, follow the instructions below: 1 Ensure that all three files generated when the measurement package was archived are placed in the same folder (see Archive): c CX2 file c SIG file c Text document 2 Select the Archiving option in the Functions menu on the Cedex Control Center and choose the option Restore. The Restore dialog box appears, with ADD and REMOVE buttons located on the right-hand side of the dialog box: Figure Click on the ADD button; an Open archive files(s) dialog box opens in which measurements to be imported are selected. 4 Navigate to the folder where the archived measurement files are stored: D Figure 114 Only the CX2 file is shown in the Open archive files(s) dialog box. The SIG and text file must be in the same location in order for the measurement package to be successfully restored, but these two files are not visible in the Open archive files(s) dialog box. 5 Select the measurements to be restored, and click on Open. The Restore dialog box reappears showing the measurement selected for importing and with the IMPORT button activated: Figure To restore further measurements located in other folders, click on the ADD button, and select the measurements via the Open archive files(s) dialog box, as described in Steps 4 and 5. ccc Software 135

171 Administrator Functions Archiving Data 7 Once you have selected all measurements to be restored, click on the RESTORE button to start the restore process. A message dialog appears when the measurements have been successfully restored. Click on OK. 8 Click on to close the Restore dialog box Deleting Archived Data Only data that has been archived can be deleted from the Cedex System database. Archived data still located in the database can be searched for and displayed in the Measurement List dialog box. D Figure 116: Measurement List dialog box with archived measurement shown To delete archived data, do the following: 1 Click on the Archived measurements(s) checkbox in the upper right-hand corner of the Measurement List dialog box. 2 Click on Find to display archived measurements. Highlight measurements to be deleted by clicking on the field on the left of the appropriate line. When choosing a set of measurements, hold the <Ctrl> button down while selecting the appropriate lines. 3 Click the checkbox beside Delete records if all measurement data is to be deleted from the system database. If the option Delete only images is chosen, all data apart from the images will stay in the system database. 4 Click on the Delete button to delete selected measurements from the Control Unit database. 136 Cedex Analyzer Operator s Guide

172 Administrator Functions Archiving Data Reducing the Size of the Database After Archiving Data The Archive function does not decrease the size of the database file after archiving measurements, even if the checkbox to delete the measurements and images has been selected. The space where deleted data was removed is only assigned to be overwritten by future measurement data. Therefore, the size of the database file will remain the same until the assigned database space has been filled with new data. Since a large database may cause the Cedex Software to slow down, the database file size should be reduced if the size of the file exceeds 10 GB. Reduce the database file size with the use of the CX2_backup.bat and CX2_restore.bat batch files located on the Cedex Software CD under User Additional Features\ Reducing the Database File Size. Step-by-step instructions for this procedure, Reducing Cedex Database Filesize are located in the folder User Additional Features\Reducing the Database File Size on the Cedex Software CD. D Software 137

173 Administrator Functions Backing up the Database 7.7 Backing up the Database In addition to the complete measurement data (including the images), the database contains also the entries for the System Options and User Preferences. A backup system should be implemented to avoid any loss of data in case of a computer failure and to allow access to measurement results after a long period of time. A backup creates a copy of the current database on a second medium that then exists in addition to the original database. Creating a backup copy enables restoration of the database with the copy in case of data loss or corruption of the original database. This is especially useful for the full restoration of a system (e.g., crash recovery) Basic Backup of the Database The easiest way to back up the Cedex Software database is to copy the complete database file, Cedex.fdb, to a different medium (e.g., portable hard drive, network, etc.) at regular intervals. In case of a crash, after the necessary reinstallation of the Software, the database file can simply be replaced by the backup file. To create a backup of the Cedex Software database, do the following: 1 Shut down the Cedex Client and Cedex Server. D 2 Open a Windows Explorer window. 3 Navigate to the C:\ folder and select the folder Cedex2 (default path C:\Cedex2). Press <Ctrl+C> (Copy) to copy the complete C:\Cedex2 folder, which contains the database file (Cedex.fdb). 4 Navigate to the external hard drive, network share, etc., where the backup should be stored. 5 Press <Ctrl+V> (Paste) to initiate copying of the Cedex2 folder to the new location. 6 Wait until the copying process has been completed successfully. This may take several hours, depending on the size of the database Incremental Backup of the Database Because the basic backup method may be time-consuming and use a lot of memory space, Roche recommends an incremental backup procedure. An incremental backup is a method whereby multiple backups are kept. The backups are incremental in the sense that each original piece of backed up information is stored only once, and successive backups only contain the information that has changed since a previous backup. An incremental backup can be created with a tool available for the Firebird DBMS - Database Management System, nbackup, located on the Cedex Software CD. More information about the nbackup tool is provided in the file nbackup_firebird back up located in the folder User Additional Features\Backing up the Database on the Cedex Software CD. 138 Cedex Analyzer Operator s Guide

174 E Maintenance and Care The Analyzer should be regularly serviced to guarantee optimal performance and maximize the life span of the Cedex Analyzer. This includes the following maintenance procedures: c Recurrent manual maintenance and cleaning routines when necessary. c Cleaning routines with the Liquid Management. c Cleaning and maintenance of the Syringe Module. c Maintenance of the capillary tubes. c Maintenance of the flow chamber, the microscope optic and the 8-way valve. This maintenance routine must be carried out only by an authorized service technician. This chapter provides detailed instructions and guidelines for each individual cleaning and maintenance procedure. E Maintenance and Care 139

175 Cleaning and Maintenance Checklist 1 Cleaning and Maintenance Checklist This checklist shows when each cleaning and maintenance routine should be done. Carry out these routines on a daily basis: c LM Shutdown: always after the last measurement and before a Cedex Analyzer shutdown. If a Prime has been scheduled to be automatically run the next morning, the Hardware Management should not be shut down as a Prime can only be run when the Hardware Management is active (see Scheduling Automatic Cleaning Routines ). c Standard Clean: after the final measurement of a set of samples or before a longer pause between measurements. c Chamber Clean 2: at least twice a day. Carry out these routines on a weekly basis: c Intensive Clean c Change of Trypan Blue solution The following routines should be done every week for users that refill reagents themselves: c Empty the reagent containers and the waste container. c Thoroughly clean the containers. c Refill the reagent containers (see Refilling Containers Individually ) Carry out this routine twice per month. E c Special Intensive Clean: at least twice a month with N HCl instead of detergent. Carry out these routines on a regular basis (once a week or after 250 measurements): c Clean the casing, Reagent Tray, Multi Sampler housing (if installed) and Reagent Port by wiping down with 70% alcohol and a lint-free cloth. c Run a focus adjustment of the Analyzer every month or after any change of position or vibration of the measurement system. 140 Cedex Analyzer Operator s Guide

176 Scheduling Automatic Cleaning Routines 2 Scheduling Automatic Cleaning Routines Routine cleaning operations can be scheduled so that they are automatically included in the process queue. Depending on the settings, the cleaning operations are automatically run at a pre-defined time or after certain events. To create a new entry in the schedule, proceed as follows: 1 Select Scheduling from the Functions menu in the Cedex Control Center. The Schedule dialog box will appear. 2 Click on New to open the Schedule process dialog box. 3 Select the Process that is to be included in the schedule from the drop-down menu at the top of the dialog box. The available processes include both cleaning routines (e.g., Fast Clean) and Hardware Management routines (e.g., Prime, LM Shutdown). 4 Select one of the three options with regard to the time schedule for an automatic process: c Every: The process is automatically run at the selected interval of one or more days. A specific time of the day for operation can also be set. c After an event: The process is automatically run after system startup or after a selectable number of measurements. c After certain time of inactivity: A certain amount of time of inactivity can be defined after which the process is run automatically. If the only once box is checked, the scheduled process will only be run once, even if there is another period of inactivity afterwards. 5 Click on Save to add the entry to the Schedule list. The Schedule process dialog box will automatically close and the Scheduling dialog box will reappear showing the newly scheduled process in the list. Scheduled processes can also be edited and deleted by highlighting the appropriate row in the Schedule dialog box and then clicking on the Edit or Delete buttons. Clicking on the Edit button will open the Schedule process dialog box in which the process can be edited. When scheduling an LM Shutdown or a Prime, it is important to ensure that the Hardware Management is not shut down before the scheduled Prime or LM Shutdown is run (e.g., the hardware is shut down in the evening before a scheduled Prime is to be performed in the morning). Prime and LM Shutdown can only be executed if the Hardware Management is active. E Maintenance and Care 141

177 Daily and Manual Maintenance and Cleaning Routines Checking the Reagent Containers When Manually Refilling 3 Daily and Manual Maintenance and Cleaning Routines The following cleaning and maintenance routines should be carried out on a regular basis or whenever necessary. 3.1 Checking the Reagent Containers When Manually Refilling Empty reagent containers lead to wrong measurement results and can cause a dry run, thereby damaging the syringe and the 8-way valve. Regular checks of the liquid level are done via the Reagent Kit Status dialog box, which is located under the Functions menu. For safety reasons, the liquid level of the individual reagent containers, as well as the capillary positions, should also be manually checked before each measurement and, if necessary, replaced or refilled. For detailed information, see Refilling Containers Individually. Cleaning the reagent containers when manually re-filling All reagent containers must be thoroughly cleaned at regular intervals and rinsed with distilled or deionized water. Impurities caused by dust or fluff must absolutely be avoided! The Trypan Blue is especially critical as it can become contaminated with microorganisms. In the case of such contamination, exact measurements are no longer possible. If the Trypan Blue solution is contaminated, intense areas may be visible in the image that will make image analysis difficult or even impossible. Replacing the reagents after 5 days is recommended. For detailed information, see Refilling Containers Individually. E 3.2 Cleaning Routines Carried Out by the Liquid Management The Liquid Management plays a key role in the Cedex Analyzer. It is necessary to Prime the system at the beginning of the day, and to carry out an LM Shutdown prior to shut down of the system in the evening (see Carrying Out an LM Shutdown and HW Shutdown ). The Liquid Management automatically runs an Ultra Fast Clean routine after every sample measurement. During the Ultra Fast Clean (approx. 30 seconds), the entire Liquid Management system, including capillary tubes, flow chamber and sample port, are rinsed out thoroughly. Manual cleaning routines can be carried out in the Cleaning dialog box. To open the Cleaning dialog box, click on the Clean button in the Shortcuts area of the Cedex Control Center or select Cleaning routines in the Functions menu (see Figure 117). Figure 117: The Cleaning dialog box of the Analyzer 142 Cedex Analyzer Operator s Guide

178 Daily and Manual Maintenance and Cleaning Routines Cleaning Routines Carried Out by the Liquid Management Cleaning Options The following cleaning routines can be run manually: c Fast Clean c Standard Clean c Intensive Clean c Chamber Clean 1 c Chamber Clean 2 Fast Clean and Standard Clean involve the entire Liquid Management system including capillary tubes, flow chamber and sample port. Therefore, always ensure that there is a Cedex Sample Cup attached to the sample port to prevent flooding. Fast Clean (with detergent, and distilled water for approx. 60 seconds) The entire Liquid Management system is rinsed with distilled water, then with detergent and finally with distilled water. Use this routine between measurements to remove dirt particles and air bubbles quickly from the flow chamber. Standard Clean (with cleaning solution, detergent, and distilled water for approx. 90 seconds) The entire Liquid Management system is rinsed with distilled water, cleaning solution, detergent and finally with distilled water again. This routine removes dirt particles and is used after measuring a set of samples or before a longer pause. Intensive Clean (with cleaning solution, detergent, and distilled water for approx. 20 minutes) The flow chamber is thoroughly rinsed with distilled water, cleaning solution, distilled water, detergent and finally distilled water. The detergent remains in the flow chamber for a longer period to work on resistant particles. The Intensive Clean routine is used on weekly basis to remove heavy and resistant contamination of the flow chamber, capillaries tubes, syringe and 8-way valve. Even the smallest dirt particle attached to the glass wall of the flow chamber can negatively influence a measurement. See also Live View of the Flow Chamber. If measurement values within a sample measurement show large variations, this could indicate that the flow chamber is soiled. E Intensive Clean with HCl A special Intensive Clean is required twice per month for a thorough cleaning. For this cleaning, a solution of N HCl is used instead of detergent. Follow the instructions below: 1 Remove the Detergent container and replace it with an appropriate container with a N HCl solution, taking care that the capillary tube reaches far enough into the solution. 2 Start Prime. 3 Start Intensive Clean after Prime has ended. 4 Replace the HCl container with the Detergent container at the end of the Intensive Clean process. 5 Start Prime again. 6 Start Standard Clean after Prime has ended. Maintenance and Care 143

179 Daily and Manual Maintenance and Cleaning Routines Cleaning Routines Carried Out by the Liquid Management The Chamber Clean 1 and Chamber Clean 2 cleaning routines are only required for the flow chamber. Chamber Clean 1 (with water for approx. 10 seconds) The flow chamber is rinsed at high pressure with distilled or deionized water being drawn in through the syringe. Use this routine to remove resistant protein aggregates, fluff particles or other obstructions from the flow chamber. Chamber Clean 2 (with water, detergent, and air for approx. 30 seconds) This routine is more intense than the Chamber Clean 1 procedure. Once the flow chamber is rinsed with water and detergent, the remaining liquid in the capillary tubes between the syringe and valve head is drawn through the flow chamber and then pressed back again with compressed air. Use this routine twice daily to remove resistant protein aggregates, fluff particles or other obstructions from the flow chamber The Hardware Management Dialog Box Prime and LM Shutdown can be executed in this dialog box. An LM Shutdown must be carried out after the last measurement has been run and before shutting down the Cedex Software. The Liquid Management system is then prepared for an extended pause, such as overnight or on the weekend. An LM Shutdown is automatically preceded by a Standard Clean routine. The 8-way valve is then rinsed with distilled or deionized water to prevent crystallization, and compressed air finally presses the Trypan Blue solution back into its container (see Carrying Out an LM Shutdown and HW Shutdown ). E Carrying Out a Cleaning Routine The different cleaning routines always have the same starting procedure. Ensure that there is always a Cedex Sample Cup attached to the single sample port or placed in the DefaultCup position on the Multi Sample Tray. Follow the instructions below: 1 Click on the Clean button in the Shortcuts area of the Cedex Control Center or else select Cleaning Routines in the Functions menu. The Cleaning dialog box will open. 2 Click on the appropriate button (e.g., Fast Clean) to automatically start the cleaning routine. The Cedex Analyzer is blocked during the cleaning routine, and the duration is continuously displayed in the Estimated Total Time field. 144 Cedex Analyzer Operator s Guide

180 Daily and Manual Maintenance and Cleaning Routines Live View of the Flow Chamber Interrupting/Terminating a Cleaning Routine Use the EMERGENCY STOP button to interrupt the cleaning routine immediately if any leaks are detected in the Liquid Management system, even in the case of an Ultra Fast Clean being carried out automatically. The Intensive Clean procedure can be interrupted to shorten the long detergent phase in the flow chamber. Click on the Cancel button, which is only activated during the long detergent phase, in the Liquid Management dialog box. 3.3 Live View of the Flow Chamber The Live View option can be activated by clicking on the appropriate checkbox in the Cleaning dialog box. This function allows for monitoring of the area in the flow chamber from which images are taken in order to check the effectiveness of a cleaning routine. In the Previous area, an image of the previous state of the flow chamber is displayed while the Current area on the right presents a live view of the flow chamber after a cleaning routine has been carried out. The Live View should be turned off while a measurement or cleaning routine is being carried out. If it has not been turned off, the Live View will be automatically stopped and the message, warning: live view has been stopped automatically, will appear in the message area of the Cedex Control Center. E Maintenance and Care 145

181 Automatic Adjustment 4 Automatic Adjustment The automatic adjustment adjusts the focus position to ensure that images of consistent quality are taken during measurements. The service technician will carry out a focus adjustment before the initial operation of the Cedex Analyzer. The focus adjustment is always necessary after the Analyzer has been moved. Additionally, Roche recommends running a focus adjustment once per month for control purposes. Both the brightness and the focus on the objects to be examined are optimally set during this focus adjustment. The focus adjustment lasts approximately 20 minutes and is done with the Cedex Calibration Beads included in the contents of delivery. If at all possible, the Analyzer should never be turned off. If it is necessary to turn it off, the Analyzer needs at least 2 hours to warm up before an Automatic Adjustment can be carried out. Proceed as follows to do the focus adjustment: 1 Open the Functions menu in the Cedex Control Center s menu bar. 2 Click on Automatic adjustment to open the Automatic Adjustment and Alignment Verification dialog box. 3 Pipet 1 ml of a well-mixed bead solution (Cedex Calibration Beads) into a Cedex Sample Cup. E 4 Attach the Cedex Sample Cup to the sample port, or place the Cedex Sample Cup in the DefaultCup position on the Multi Sample Tray (see The Multi Sampler DefaultCup ). 5 Click on the Start Automatic Adjustment button. You will be asked to verify that the beads have been prepared. Click on OK to confirm and start the adjustment process. 146 Cedex Analyzer Operator s Guide

182 Automatic Adjustment Figure 118: The Automatic Focus Adjustment dialog box after adjustment The automatic adjustment is automatically carried out in several steps. First, water is pumped into the flow chamber, after which the Cedex Calibration Beads are injected into the flow chamber. The complete path of the microscope stage is scanned as it moves to its lowest and then to its highest position. Based upon the obtained image information, a preliminary focus position is set. The area around the located focus position is then examined closely and scanned several times to find the optimal focus. An automatic cleaning of the flow chamber and the capillaries is done at the end of the adjustment. The focus adjustment s time-progression is displayed as an estimated value in the form of a blue progression bar. The focus quality for every stage/focus position is displayed in a diagram. A distinct peak around the middle of the graph indicates the optimal focus position. The following criteria can be inspected to evaluate the result of an automatic focus adjustment: c Verify that the pink line marking the newly set focus lies within close range of the distinct peak. c New and previous focus position values are both displayed in the message box appearing at the end of the focus adjustment. Ensure that variations between these values don t exceed a range of +/-30. c The image quality should be checked. A valid image shows clearly outlined beads with a bright cell interior. E If any one or more of these criteria is not met, an authorized service technician must re-adjust the Cedex Analyzer. The Automatic Adjustment and Alignment Report can be printed out via the Print Report button. Maintenance and Care 147

183 Syringe Maintenance Removing the Syringe 5 Syringe Maintenance Moving parts of the Syringe Module may cause hand injuries. Never run a measurement on the Cedex Analyzer without the protective cover for the Syringe Module in place. When performing a syringe maintenance, be aware of the risks from moving parts. The flow chamber, tubes, syringe and 8-way valve are cleaned during the Intensive Clean routine carried out by the Liquid Management (see Cleaning Options ). However, the syringe is subject to wear and tear and must, therefore, be regularly replaced to maximize the life span of the 8-way valve and to guarantee optimal performance. The syringe should be replaced approximately every 6 months under normal use of the Analyzer. More frequent use may require more frequent changing of the syringe. To change the syringe, follow the steps specified in the sections below: 5.1 Removing the Syringe Follow the instructions below: 1 Click on Syringe Maintenance in the Functions menu of the Cedex Control Center. The Syringe Maintenance dialog box will open (see Figure 119). 2 Click on the Remove Syringe button. The syringe barrel will be moved to a position to allow easy removal. 3 Remove the protective cover. E 4 Hold the syringe barrel by the Luer lock and turn it counter clockwise to remove it from the 8-way valve (see Figure 120). 5 Once the connection is loosened, keep holding the syringe barrel in an upright position beneath the 8-way valve to prevent it from jamming with the plunger. 6 Remove the bottom screw that connects the plunger to the Syringe Module with the other hand. 7 Remove the syringe from the Syringe Module. Figure 119: Syringe Maintenance dialog box 148 Cedex Analyzer Operator s Guide

184 Syringe Maintenance Assembling and Installing the Syringe Luer lock Syringe barrel Bottom screw connecting plunger to Syringe Module Figure 120: Syringe 5.2 Assembling and Installing the Syringe Rinse a new syringe with 70% alcohol and then with distilled or deionized water before installing it. Follow the instructions below: 1 Gently press the plunger into the syringe barrel. 2 Insert the syringe back onto the Syringe Module. 3 Hold the syringe barrel by the Luer lock and turn it clockwise into the port of the 8-way valve. E 4 Secure the plunger to the Syringe Module with the screw at the bottom. Ensure that the syringe barrel and plunger do not get jammed. 5 If the Syringe Maintenance dialog box has not been opened yet, select Syringe Maintenance in the Functions menu on the Cedex Control Center. 6 Click on the Install button. The plunger will be correctly positioned and the Syringe Module initialized. 7 Ensure that there are no leaks in the Liquid Management system. This can be done with one of the cleaning routines in the Cleaning dialog box. Interrupt the cleaning procedure immediately with the EMERGENCY STOP button if there are any leaks in the Syringe Module. 8 Put the protective cover back on. Never use the Cedex Analyzer without the protective cover on the Multi Sampler and Syringe Module. Maintenance and Care 149

185 Syringe Maintenance Maintenance of the Syringe Guide and Spindle 5.3 Maintenance of the Syringe Guide and Spindle The syringe guide and spindle are mounted on either side of the Syringe Module inside the casing (see Figure 121). They should be lubricated twice a year (or, when necessary, more often, for example, if you hear noises coming from the syringe guide) with the lubricant supplied by your local Roche representative to guarantee optimal performance of the syringe. Follow the instructions below: 1 Remove the syringe (see Removing the Syringe ). 2 Switch off the Cedex Analyzer. 3 Lubricate the top part of the syringe guide and spindle. 4 Switch on the Cedex Analyzer. 5 Click on Install in the Syringe Maintenance dialog box. 6 Switch off the Cedex Analyzer. 7 Lubricate the bottom part of the syringe guide and spindle. 8 Switch on the Cedex Analyzer. 9 Click on Remove Syringe in the Syringe Maintenance dialog box. 10 Install the syringe (see Assembling and Installing the Syringe ). E Syringe guide Spindle Figure 121: Syringe Guide and Spindle 150 Cedex Analyzer Operator s Guide

186 Maintenance of the Flow chamber, Microscope Optic, 8-Way Valve and the remaining Hardware Components 6 Maintenance of the Flow chamber, Microscope Optic, 8-Way Valve and the remaining Hardware Components To ensure that the Cedex Analyzer functions uninterruptedly, maintenance work is necessary at regular intervals. An arrangement for a maintenance contract with your local Roche representative is recommended. During maintenance, worn-out and defective components are replaced and the functioning of the Cedex Analyzer checked. Only an authorized service technician is permitted to carry out maintenance when the Cedex Analyzer needs to be opened! 7 Operational Data The Cedex System keeps track of some operational data including operating hours, number of measurements and liquid consumption. Select Operational Data in the Functions menu of the Cedex Control Center to open the Operational Data dialog box. The values on the left-hand side of the dialog box can be set to 0 by clicking on the Reset button. This can be useful for tracking the operational information for short periods of time. The values on the right-hand side track the overall operating hours, number of measurements and liquid consumption. These values cannot be reset. A report of the operational data can be printed out via the Print Report button. E Maintenance and Care 151

187 The System Suitability Test (SST) Creating SST Checkpoints 8 The System Suitability Test (SST) To ensure proper operation of the Cedex Analyzer and valid analysis results, it is essential that the system is in good condition. The majority of the critical parameters are regulated by design or preventive maintenance activities carried out by local Roche Technical Service. The routine checkups performed by the user of the Cedex Analyzer mainly focuses on the liquid management process (such as flow chamber, capillaries, etc.). A feature of the Cedex Software 2.3, the System Suitability Test (SST), is designed to help monitor the state of the system for quality supervision/assurance purposes. A routine checkup procedure that meets the system owner s specific needs can be created using the SST Software feature. Verification that the Analyzer is in the required condition comprises both manual checks (internal as well as external scrutiny of the equipment, for example chamber inspection) and various checkup and calibration measurements. These individual procedures are known as SST checkpoints. When an SST is set up on a Cedex System, checks and measurements will have to be performed on a regular basis. Passing the checkpoints will then be mandatory for normal continuation of measurement procedures. The System Suitability Test consists of different types of SST checkpoints. Each checkpoint needs to be created and its parameters, including the acceptance criteria, configured by an authorized user (the Superuser or Administrator). Once created and activated, the checkpoints apply to the whole system. E 8.1 Creating SST Checkpoints The System Suitability Test consists of different types of SST checkpoints. There are two main types of checkpoints: an SST requiring inspection or maintenance activity performed by the user (e.g., syringe change, chamber inspection) and SST procedures involving measurements with either Cedex Control Beads or Density Reference Standard Beads. In order to pass a checkpoint involving Control Beads measurements, the average result of a pre-defined number of one or more measurements needs to be valid according to the checkpoint criteria. A checkpoint requiring an inspection or maintenance activity demands an active confirmation in the System Suitability Test dialog box that the activity or inspection has been performed. Each checkpoint needs to be created and its parameters, including the acceptance criteria, configured by an authorized user. For this, authorized users need to be assigned the SST edit function. Users who perform SST procedures only need access to the SST run function. Once created and activated, the checkpoints apply to the whole system. On some systems, an inactive list of proposed SST checkpoints may be automatically provided in the System Suitability Test List dialog box. To activate these checkpoints, click in the box under the Active column for the checkpoint. A checkmark will appear in the Active column, which indicates that the checkpoint has been activated. 152 Cedex Analyzer Operator s Guide

188 The System Suitability Test (SST) Creating SST Checkpoints Creating SST Checkpoints with and without Measurements To create a new SST Checkpoint, proceed as follows: 1 Click on SST in the Functions menu to access the System Suitability Test List dialog box, or click directly on the SST button in the Cedex Control Center. 2 Click on the New button and the System Suitability Test New dialog box will appear. Using this dialog box, a measurement checkpoint or a manual checkpoint can be created. 3 To create a checkpoint for a manual check or maintenance activity, click on the SST Without Measurement button. This will open the System Suitability Test New dialog box that allows for the creation of a checkpoint for a manual check. Enter an SST Name (e.g., Flow Chamber) and an SST Description that provides sufficient information for any user performing this SST. 4 To create checkpoints for calibration measurements, click on the SST including Measurement button. The appropriate System Suitability Test New area will appear. A set of parameters needs to be defined. See Table 2, for a detailed description of the parameters. 5 Click on the Save button to create a new SST checkpoint. The checkpoint will immediately be added to the System Suitability Test List. 6 Clicking on Close will close the dialog box without creating an SST checkpoint. Parameters for SST including Measurement: SST Name/SST Description Overall Type Cell Type/Measurement Precision/ Sample Volume/ Sample Initial Dilution Target Value Offset Target Value Check / Upper Limit / Lower Limit Fixed Target Value Count For Passing Enter an SST Name and Description for identification purposes during routine checkup procedures. Select the characteristic that is to be inspected during the measurements for this checkpoint (e.g., Total Cell Count, Total Concentration) from the drop-down list. Define different measurement parameters for different checkpoints to verify operational reliability in various situations. The Target Value serves as benchmark for the acceptance criteria. It can be based, for example, on the average result of a set of measurements carried out with Cedex Control Beads. The offset in % determines the acceptance range applicable to the results of SST measurements carried out for this checkpoint based on the target value entered. If the Target Value Check is activated, the user carrying out SST measurements can enter another target value before running the first SST measurement for this checkpoint (e.g., when a new container of Control Beads is used). Acceptable limits for what can be entered by a user for the variable target value are set using Upper Limit and Lower Limit fields. Note: the Upper Limit and Lower Limit fields are not related to the acceptable range for results from an SST measurement. The acceptable range for results is determined by the % entered in the Offset field. If the target value is not entered by users, the Fixed Target Value must be activated. Count for Passing refers to the number of SST measurements that has to be carried out for this checkpoint. E Table 2: SST parameters for SST with Measurement Maintenance and Care 153

189 The System Suitability Test (SST) Creating SST Checkpoints In general, the Target Value is determined before the SST checkpoint is activated. For further information on the procedure for the determination of a target value, Roche Technical Service provides appropriate recommendations. It is necessary to re-determine the target value if a new container of Cedex Control Beads is used. An SST checkpoint includes a validity period. This can be set in the System Suitability Test List in the Days Valid column. After this period of time, the SST procedures must be performed. If the SST procedure is not performed within the validity period, all measurements apart from SST measurements will be prohibited (e.g., the system status is changed to MeasurementLock) Running a Water Blank Before an SST including Measurement can be run, a water blank (Water For Injection [WFI]) should be run to check the condition of the reagents. No more than 20 counts should be recorded for this measurement. This can be scheduled using the SST including Measurement button (see Creating SST checkpoints with and without measurements ). The WFI measurement requires a relative deviation rather than an absolute deviation, which means that 0 cannot be used as a Target Value as a relative deviation from 0 will always be 0. Therefore, when setting up a WFI measurement, the Target Value should be set to 10 with a relative deviation of 100%. This will result in an acceptance range of 0 20 objects (see Table 2) Setting up the SSTFailureReaction in the System Options Menu The reaction of the system to an SST failure depends on the configuration in the System Options. The System Options dialog box can be accessed under the Setup menu on the Cedex Control Center: E 1 Open the System Options dialog box and click on the General tab. 2 Look for the parameter SSTFailureReaction. c Entering Restrict in the Value column will lead to prohibition of any further measurements, including SST measurements, in the event of an SST failure. This will require a manual unlocking of the system in the Lock Unlock System area before measurement activity can be resumed (see Locking Unlocking the System ). c If Warning is entered, measurement activity can be continued but there will be a warning about SST failure before a measurement is carried out. c Choosing the Audit option will simply lead to a log entry in the audit trail file in the case of an SST failure. There will not be any restrictions or warnings. 3 Click on Save to store the change. Measurements that are run despite the fact that not all SST procedures are up to date or valid will have no checkmark in the SST Valid box in the Measurement dialog box. 154 Cedex Analyzer Operator s Guide

190 The System Suitability Test (SST) Performing an SST 8.2 Performing an SST All procedures related to the System Suitability Test can be controlled via the System Suitability Test List. To access the list, open the Functions menu in the Cedex Control Center and click on SST or directly click on the SST button in the Cedex Control Center. The System Suitability Test List provides an overview of all SST checkpoints and their current status. Valid SST checkpoints are displayed in black while red indicates an invalid checkpoint. SST checkpoints need to be carried out at regular intervals, the length of these intervals being specified in the Days Valid column. To confirm a checkpoint, either manual checks have to be done or measurements need to be carried out. It is recommended to include confirmation of checkpoints in the daily/weekly work routine and not to wait until the validity period of a checkpoint has expired Performing an SST with Measurements If the SST to be performed requires a measurement or series of measurements, do the following: 1 Select SST from the Functions menu on the Cedex Control Center. Alternatively, click on the SST button in the Shortcuts area of the Cedex Control Center. The System Suitability Test List dialog box will appear. 2 Select the SST checkpoint to be confirmed by clicking on the field to the left of the appropriate line. 3 Click on Run SST to start the SST procedure. The System Suitability Test Measurement Run dialog box will appear. The parameter settings can be viewed but not altered. 4 Whether or not the Target Value can be changed depends on configuration. If the Fixed Target Value option is not activated, the user will be able to change the target value. However, if the Target Value Check is activated, the user will have to enter a value within the defined limits (Upper Limit, Lower Limit). 5 Click on Run to start the SST measurement. The Measurement dialog box will appear and the measurement will be carried out automatically. 6 Close the Measurement dialog box. 7 Repeat measurement as often as required for this checkpoint (see note below). E The Count For Passing value given in the System Suitability Test Measurement Run dialog box indicates the number of measurements that have to be carried out for this checkpoint. The average value will be calculated from all of the measurements required for a particular SST checkpoint. The average value of all test measurements needs to be within the acceptance range. The acceptance range is defined by the target value and the offset (in %). In the event of an invalid SST measurement, the system will immediately be locked. Once in SSTLock, the system needs to be unlocked manually by authorized users before any further SST or other types of measurements can be carried out. If the average result of all test measurements for an SST checkpoint is valid, the checkpoint will automatically be displayed in black. Maintenance and Care 155

191 The System Suitability Test (SST) Tracking Trends in SST Results Over Time Performing an SST without Measurements For SST procedures that don t require any measurements, clicking on the Run SST button will open the System Suitability Test Run dialog box. The SST Name and/or Description should provide information regarding the nature of the manual check or the maintenance step that needs to be taken. Once the System Suitability Test Run dialog box has been opened, do the following: 1 Perform the required inspection or maintenance routine. 2 Click on the Valid checkbox in the middle of the System Suitability Test Run dialog box if inspection or maintenance procedure was successful. 3 Add a comment in the Comment box (optional). 4 Click on the Save button to confirm the completion of the SST check and return to the System Suitability Test List dialog box. If the valid checkbox has been activated, the checkpoint will automatically be displayed in black in the System Suitability Test List dialog box. E Figure 122: System Suitability Test List dialog box On some systems, an inactive list of proposed SST checkpoints may automatically be provided in the System Suitability Test List dialog box. Check with the Administrator to see if these SST checkpoints should be activated. 8.3 Tracking Trends in SST Results Over Time The results of SST checkpoints can be tracked over time using the SST Trending button. Trends for both checkpoints with and without measurements can be tracked Tracking Trends in SST Checkpoints with Measurements To see all of the results over time from a particular SST checkpoint with measurements, do the following: 1 Select the SST checkpoint to be monitored by clicking on the field to the left of the appropriate line. 2 Click on the SST Trending button to open the Trending list for SST with measurement dialog box (see Figure 123). 156 Cedex Analyzer Operator s Guide

192 The System Suitability Test (SST) Tracking Trends in SST Results Over Time All of the measurements for the selected SST checkpoint are listed in this dialog box. The Filter by area in the bottom left-hand corner can also be used to search for and list specific measurements based on date run and Reactor ID. The information in the Trending list for SST with measurement dialog box can be exported via the Export button or printed via the Print button. The SST checkpoint results are displayed in the result column in the units of the Overall Type selected for that particularly SST checkpoint. Clicking on the normalized view checkbox will normalize the results to the target value and display the differences in percent. To create a chart showing result trends over time, do the following: 1 Click on the use checkbox to mark the measurements that should be included in the calculations for the trending chart. A indicates that the measurement will be used. All measurements will be included on the Trending Chart, but excluded measurements will be circled in red and not used for curve calculations. 2 Click on the Trending Chart button to create a Trending Chart. Figure 123: Trending list for SST with measurement dialog box E Clicking on the Trending Chart button will open a Trending Chart dialog box showing all of the SST measurements (marked on the chart) (see Figure 124). If multiple measurements were required for a particular checkpoint, the average of the measurements is marked by, while the results from the individual measurements for that checkpoint are marked with an. In addition, the following parameters are included: c Target value c Upper limit c Lower limit c Invalid checkpoints ( s ) c Mean value c Moving average c Variation coefficient The Trending Chart can be enlarged or reduced (see Enlarging the Histograms ), and can be printed out via the Trending chart print button. Maintenance and Care 157

193 The System Suitability Test (SST) Tracking Trends in SST Results Over Time Figure 124: Trending Chart dialog box There are several additional options in the Trending Chart dialog box. Excluded measurements can be removed from the chart completely by clicking on the show excluded checkbox to remove the checkbox. For SST checkpoints with multiple measurements, the individual measurements can be removed from the chart by removing the checkmark in the box next to single measurements, leaving only the average of the measurements. E Clicking on the normalized view checkbox will normalize the results to the target value and display the differences in percent. Both the mean curve and the moving average curve can be shown or hidden by selecting or de-selecting the appropriate checkboxes Tracking SST Checkpoints without Measurements To see results from SST checkpoints without measurements over time, do the following: 1 Select the SST checkpoint to be monitored by clicking on the field to the left of the appropriate line to highlight the whole line. 2 Click on the SST Trending button to open the Trending list for SST without measurement dialog box (see Figure 125). All of the measurements for the selected SST checkpoint are listed in this dialog box. The Trending list for SST without measurement dialog box shows all comments given for each SST check that was made and indicates whether the checkpoints passed or not. The list can be printed out via the Print button or exported in either a CSV or Excel-DIF format via the Export button. Figure 125: Trending list for SST without measurement dialog box 158 Cedex Analyzer Operator s Guide

194 The System Suitability Test (SST) Locking Unlocking the System 8.4 Locking Unlocking the System Measurements that are carried out after the validity period of an SST checkpoint has expired are marked as invalid in the Audit Trail. In addition, the system may be locked for any further routine measurements except SST measurements. The System Status describes the capability of the system for performing certain tasks involving the hardware. The current state of the system can be viewed in the Change System Status dialog box, which is accessed by selecting the Lock Unlock System option in the System menu of the Cedex Control Center (see Figure 126). The state of the system is set automatically depending on the validity of all SST checkpoints, and the configuration of the SSTFailureReaction parameter in the System Options. Depending on the configuration, if an SST checkpoint is out of date, only SST measurements can be carried out. No routine measurements will be possible (Current State: MeasurementLock). Once all SST checkpoints are up to date and valid again, the system is fully usable and the Current State is automatically set to SystemOK. In the event of a failed SST procedure, the system may be locked for any further measurements, including SST measurements (this is only the case if the SSTFailureReaction parameter in the System Options dialog box is set on Restrict (see Setting up the SSTFailureReaction in the System Options menu ). The Current State will be automatically set to SSTLock. The system status can be changed manually by authorized users. Manually changing the system status may be necessary for a variety of reasons. For more details, see the following table: Manually set System Status to: ManualLock SSTManualUnlock MeasurementManualUnlock Warning SystemOK Table 3: Manually settable system status Description of the manually set System Status: Any action involving hardware is prohibited. SST measurements (and any other process involving the hardware except routine measurements) are allowed. System is fully usable but all measurements are marked as Invalid because of SST failure in the Audit Trail. System is fully usable but there will be a warning before a measurement is run, and the measurements will be marked Invalid because of SST failure in the Audit Trail. System is fully usable until system rechecks validity of SST checkpoints (which is done at an interval of 300 sec.). As a possible reaction to the following automatic System Status: SSTLock after failed SST procedure. SSTLock, SSTManualUnlock or MeasurementLock SSTLock, SSTManualUnlock or MeasurementLock SSTLock, SSTManualUnlock or MeasurementLock E Maintenance and Care 159

195 The System Suitability Test (SST) Locking Unlocking the System Figure 126: System Status dialog box E 160 Cedex Analyzer Operator s Guide

Cedex HiRes Analyzer Operator s Manual

Cedex HiRes Analyzer Operator s Manual Cedex HiRes Analyzer Operator s Manual Software Version 2.3.2 June 2016 For use in quality control/manufacturing process only. How to Use the Cedex HiRes Analyzer Guides Before reading, please review the

More information

User manual user manual

User manual user manual User manual user manual User Manual Version 1.4 for Cedex XS Software Version 1.0.3 12/04/09 (MM/DD/YY) 2 Cedex XS User Manual Contents Contents Copyright...5 Disclaimer...5 Intended Use...5 Declaration

More information

Cedex HiRes Analyzer Operator s Guide

Cedex HiRes Analyzer Operator s Guide Cedex HiRes Analyzer Operator s Guide Software Version 2.3 August 2013 For life science research only. Not for use in diagnostic procedures. Table of Contents Prologue 7 I. Document Information... 7 1

More information

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up FlowAccess TM V3 Windows software for Skalar SAN plus systems Version 3.1.0.4 and up GETTING STARTED FlowAccess TM V3 Windows software for Skalar SAN plus systems Version 3.1.0.4 and up Getting started

More information

Administrator Manual Cedex Version 1.6.1

Administrator Manual Cedex Version 1.6.1 Administrator Manual Cedex Version 1.6.1 Version: Cedex 1.6.1. 10/29/03 (MM/DD/YY) 2 Administrator Manual Cedex Version 1.6.1 Contents Contents CONTENTS...3 1 RIGHTS...5 Copyright...5 Disclaimer...5 Warranty...5

More information

xponent Version 4.2 RELEASE NOTES

xponent Version 4.2 RELEASE NOTES xponent Version 4.2 RELEASE NOTES Copyright Luminex Corporation, 1996-2013. All rights reserved. Part Number: 89-30000-00-462 Disclaimer Subject to change without notice. Although prepared to ensure accuracy,

More information

Renalog RM User Guide

Renalog RM User Guide INSTRUCTION MANUAL Renalog RM User Guide SOFTWARE Part Number 50090-859/B Copyrights Copyright 2002 Minntech Corporation. All rights reserved. Information in this document is subject to change without

More information

CITO2 Installation & User Instructions

CITO2 Installation & User Instructions CITO2 Installation & User Instructions DD 56107 Stoneridge Electronics Ltd 1. Installation...4 1.1. System Requirements...4 1.2. Installing CITO2...4 1.3. Uninstalling CITO2...4 2. Starting and closing

More information

FlowAccess TM V3 USER MANUAL. Windows software for Skalar SAN plus systems. Version and up

FlowAccess TM V3 USER MANUAL. Windows software for Skalar SAN plus systems. Version and up FlowAccess TM V3 Windows software for Skalar SAN plus systems Version 3.1.11 and up USER MANUAL FlowAccess TM V3 Windows software for Skalar SAN plus systems Version 3.1.11 and up User Manual Publication

More information

Fiery proserver User Guide

Fiery proserver User Guide Fiery proserver User Guide Congratulations on your purchase of the Fiery proserver, a powerful production solution for your printer. Before you begin Make sure that you have: About this document Installed

More information

Agilent ChemStation. ECM Interface Guide. Agilent Technologies

Agilent ChemStation. ECM Interface Guide. Agilent Technologies Agilent ChemStation ECM Interface Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2005-2007 No part of this manual may be reproduced in any form or by any means (including electronic

More information

Portal Access Software Technical Manual

Portal Access Software Technical Manual Portal Access Software Technical Manual Instructions for using the Portal Access Software with the Maxprep, Maxwell RSC and Maxwell RSC 48 Instruments TM549 Revised 1/19 Table of Contents 1 Description...1

More information

PA 800 Plus Pharmaceutical Analysis System. System Administration Guide

PA 800 Plus Pharmaceutical Analysis System. System Administration Guide PA 800 Plus Pharmaceutical Analysis System RUO-IDV-05-5520-A January 2018 This document is provided to customers who have purchased SCIEX equipment to use in the operation of such SCIEX equipment. This

More information

TopPoint User's Guide

TopPoint User's Guide TopPoint User's Guide LT2152/ 2000 Gilson, Inc. All rights reserved August 2000 Table of Contents 1 Introduction 2 Operation 3 Troubleshooting Steps to Using TopPoint... 1-2 Accessing Online Help... 1-3...

More information

Verity Central Quick Reference Manual. Document ID A04

Verity Central Quick Reference Manual. Document ID A04 Verity Central Quick Reference Manual Document ID 6620-003-A04 Welcome to Verity Central. This Quick Reference Manual is intended to be used in tandem with the Verity Central Technical Reference Manual,

More information

Fiery proserver User Guide

Fiery proserver User Guide Fiery proserver User Guide Congratulations on your purchase of the EFI Fiery proserver, a powerful production solution for your printer. Before you begin Make sure that you have: About this document Installed

More information

Agilent OpenLAB ECM Intelligent Reporter

Agilent OpenLAB ECM Intelligent Reporter Agilent OpenLAB ECM Intelligent Reporter Installation and Configuration Guide Agilent Technologies Notices Agilent Technologies, Inc. 2007-2016 No part of this manual may be reproduced in any form or by

More information

Client Installation and User's Guide

Client Installation and User's Guide IBM Tivoli Storage Manager FastBack for Workstations Version 7.1.1 Client Installation and User's Guide SC27-2809-04 IBM Tivoli Storage Manager FastBack for Workstations Version 7.1.1 Client Installation

More information

ConTeS. Contamination Test Software. Operating Instruction. Valid from software version: English (translation of original instructions)

ConTeS. Contamination Test Software. Operating Instruction. Valid from software version: English (translation of original instructions) ConTeS Contamination Test Software Operating Instruction Valid from software version: 1.10 English (translation of original instructions) Documentation no.: 3606806b Trademarks Trademarks The trademarks

More information

Chromeleon-PA Analyzer User s Guide Dionex Corporation

Chromeleon-PA Analyzer User s Guide Dionex Corporation Chromeleon-PA Analyzer User s Guide 2003 Dionex Corporation Document No. 031964 Revision 01 October 2003 2003 by Dionex Corporation All rights reserved worldwide. Printed in the United States of America.

More information

ATX Document Manager. User Guide

ATX Document Manager. User Guide ATX Document Manager User Guide ATX DOCUMENT MANAGER User Guide 2008 CCH Small Firm Services. All rights reserved. 6 Mathis Drive NW Rome, GA 30165 No part of this manuscript may be copied, photocopied,

More information

Agilent ChemStation Plus

Agilent ChemStation Plus Agilent ChemStation Plus Getting Started Guide Agilent Technologies Notices Agilent Technologies, Inc. 2004, 2006-2008 No part of this manual may be reproduced in any form or by any means (including electronic

More information

UNICORN Administration and Technical Manual

UNICORN Administration and Technical Manual UNICORN 7.0.2 Administration and Technical Manual Table of Contents Table of Contents 1 Introduction... 1.1 Administrator functions overview... 1.2 Network terms and concepts... 1.3 Network environment...

More information

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1

CLIQ Web Manager. User Manual. The global leader in door opening solutions V 6.1 CLIQ Web Manager User Manual V 6.1 The global leader in door opening solutions Program version: 6.1 Document number: ST-003478 Date published: 2016-03-31 Language: en-gb Table of contents 1 Overview...9

More information

Release Notes Life Technologies Attune NxT Software v2.3

Release Notes Life Technologies Attune NxT Software v2.3 Release Notes Life Technologies Attune NxT Software v2.3 In the following pages you will find instructions describing: New software features Known software/system issues with troubleshooting guidance Software

More information

AvePoint Online Services 2

AvePoint Online Services 2 2 User Guide Service Pack 7 Issued August 2017 Table of Contents What s New in this Guide...6 About...7 Versions: Commercial and U.S. Government Public Sector...7 Submitting Documentation Feedback to AvePoint...8

More information

Overview Provides an overview of the software application functions.

Overview Provides an overview of the software application functions. Optical Disc Archive File Manager Help Overview Provides an overview of the software application functions. Operation Screens Describes the name and function of the software application screens. Operating

More information

ClonePix TM 2 QUICK SET-UP INTRUCTIONS MANUAL SOFTWARE RELEASE

ClonePix TM 2 QUICK SET-UP INTRUCTIONS MANUAL SOFTWARE RELEASE ClonePix TM 2 QUICK SET-UP INTRUCTIONS MANUAL SOFTWARE RELEASE 1.2.80.1071 07MAN1181.A1 Effective Date: 30-Jan-11 ECO #: 3093 Contents What are Quick Set-Up Instructions?... 3 Starting up ClonePix 2...

More information

AUTOMATED APPOINTMENT REMINDER AND ANNOUNCEMENT SYSTEM

AUTOMATED APPOINTMENT REMINDER AND ANNOUNCEMENT SYSTEM SARS Messages AUTOMATED APPOINTMENT REMINDER AND ANNOUNCEMENT SYSTEM USER MANUAL 2011-2015 by SARS Software Products, Inc. All rights reserved. COPYRIGHT Copyright 2011-2015 SARS Software Products, Inc.

More information

Getting Started With DO Analyser Software Version 4

Getting Started With DO Analyser Software Version 4 Getting Started With DO Analyser Software Version 4 Getting Started With The DO Analyser Sofware Version 4 Jochen Arndt SiS Sensoren Instrumente Systeme GmbH Schwentinental The author and publisher have

More information

AMS ValveLink Software Quick-Start Guide

AMS ValveLink Software Quick-Start Guide Quick-Start Guide Form 5745 September 2006 AMS ValveLink Software Quick-Start Guide D102813X012 www.fisher.com FIELDVUE, PlantWeb, ValveLink, and Fisher are marks owned by Fisher Controls International

More information

Secure Workstation for OpenLAB CDS ChemStation Edition User's Guide

Secure Workstation for OpenLAB CDS ChemStation Edition User's Guide Secure Workstation for OpenLAB CDS ChemStation Edition User's Guide Secure Workstation for OpenLAB CDS ChemStation Edition User's Guide Agilent Technologies Notices Agilent Technologies, Inc. 2014-2017

More information

Microsoft Office Groove Server Groove Manager. Domain Administrator s Guide

Microsoft Office Groove Server Groove Manager. Domain Administrator s Guide Microsoft Office Groove Server 2007 Groove Manager Domain Administrator s Guide Copyright Information in this document, including URL and other Internet Web site references, is subject to change without

More information

TraceFinder Acquisition Quick Reference Guide

TraceFinder Acquisition Quick Reference Guide TraceFinder Acquisition Quick Reference Guide This quick reference guide describes the Thermo TraceFinder acquisition tasks assigned to the Technician role. Contents Acquisition Mode Selecting a Batch

More information

Client Installation and User's Guide

Client Installation and User's Guide IBM Tivoli Storage Manager FastBack for Workstations Version 7.1 Client Installation and User's Guide SC27-2809-03 IBM Tivoli Storage Manager FastBack for Workstations Version 7.1 Client Installation

More information

Printer Driver. User Guide. Macintosh

Printer Driver. User Guide. Macintosh Card Photo Printer CP-100/CP-10 Printer Driver User Guide Macintosh 1 Contents Safety Precautions...4 Read This First...5 About the Manuals...5 Printing Flow Diagram...6 About the Connection Cable...7

More information

Virtual CD TS 1 Introduction... 3

Virtual CD TS 1 Introduction... 3 Table of Contents Table of Contents Virtual CD TS 1 Introduction... 3 Document Conventions...... 4 What Virtual CD TS Can Do for You...... 5 New Features in Version 10...... 6 Virtual CD TS Licensing......

More information

LINAX Series Videographic Recorders

LINAX Series Videographic Recorders User Guide 154534_8 LINAX Series Videographic Recorders DataManager Software Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 'Safety Requirements for Electrical

More information

Upgrading the Cisco ONS CL to Release 7.0

Upgrading the Cisco ONS CL to Release 7.0 This document explains how to upgrade Cisco ONS 15310-CL Cisco Transport Controller (CTC) software from Release 5.x or Release 6.x to Release 7.0.x, or from Release 7.0.x to a later maintenance release

More information

Nanosight NS300 NBTC User Instructions

Nanosight NS300 NBTC User Instructions Nanosight NS300 NBTC User Instructions Preliminary notes: -The laser module is delicate and expensive. Handle it with care and do not leave it on the bench unattended. Only leave it in place in the instrument

More information

Early Data Analyzer Web User Guide

Early Data Analyzer Web User Guide Early Data Analyzer Web User Guide Early Data Analyzer, Version 1.4 About Early Data Analyzer Web Getting Started Installing Early Data Analyzer Web Opening a Case About the Case Dashboard Filtering Tagging

More information

Process Eye Professional. Recall

Process Eye Professional. Recall Process Eye Professional Recall Process Eye Professional Recall User Manual SP104010.101 August 2005 As part of our continuous product improvement policy, we are always pleased to receive your comments

More information

FROG-4000TM Quick Start Guide

FROG-4000TM Quick Start Guide FROG-4000TM Quick Start Guide 1 Precautions DO NOT invert the instrument with the sparge bottle attached. DO NOT transport or store the instrument with liquid in the sparge bottle. DO NOT handle or carry

More information

Document revision: F

Document revision: F Document revision: F Important Notice Copyright 2017 Enforcement Video, L.L.C. (dba WatchGuard Video). All rights reserved. This document and supporting data are the exclusive property of Enforcement Video,

More information

UPDATES THESE RELEASES:

UPDATES THESE RELEASES: Release Notes for Amicus Attorney 2008 Premium Edition Service Pack 1 RELEASE DATE: June 2008 BUILD: 8.0.1.1 UPDATES THESE RELEASES: Premium Edition (Builds 8.0.0.2 and 8.0.1.0) Service Pack 1 (SP1) provides

More information

FaxFinder Fax Servers

FaxFinder Fax Servers FaxFinder Fax Servers Models: FF130 FF230 FF430 FF830 Client User Guide FaxFinder Client User Guide Fax Client Software for FaxFinder Series PN S000460B, Version B Copyright This publication may not be

More information

Gallios TM Quick Reference

Gallios TM Quick Reference Gallios TM Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic

More information

SIMATIC Automation License Manager Manual 02/2008 A5E

SIMATIC Automation License Manager Manual 02/2008 A5E s Contents SIMATIC Automation License Manager Product Overview 1 Installation 2 Working with the Automation License Manager 3 Glossar Index Manual 02/2008 A5E02128430-01 Safety Guidelines This manual contains

More information

Top Producer for Palm Handhelds

Top Producer for Palm Handhelds Top Producer for Palm Handhelds Quick Setup Top Producer Systems Phone number: 1-800-830-8300 Email: support@topproducer.com www.topproducer.com Fax: 604.270.6365 Top Producer for Palm handhelds Quick

More information

Table of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4

Table of Contents. 1. Intended Use Overview Materials Required System Requirements User Mode 4 Table of Contents 1. Intended Use.. 3 2. Overview.. 3 2.1 Materials Required. 3 2.2 System Requirements. 3 2.3 User Mode 4 3. Installation Instructions.. 5 3.1 Installing the On Call Diabetes Management

More information

Canto II Operation Protocol

Canto II Operation Protocol Canto II Operation Protocol Make sure the following actions have been taken before running your samples. Make sure the waste tank is empty and refilled with 500 ml clean (see page 15 for details) Make

More information

Register your instrument! PCR-Assistant. Software manual

Register your instrument!   PCR-Assistant. Software manual N) alanual Register your instrument! www.eppendorf.com/myeppendorf Software manual Copyright 2013 Eppendorf AG, Hamburg. No part of this publication may be reproduced without the prior permission of the

More information

Chapter 3.12: End-of-Month Procedures

Chapter 3.12: End-of-Month Procedures Chapter 3.12: End-of-Month Procedures Overview This chapter describes essential month-end procedures as well as other items that may be useful to your company as you create and follow a monthly routine.

More information

EMC ApplicationXtender Web Access.NET eroom Integration 6.0

EMC ApplicationXtender Web Access.NET eroom Integration 6.0 EMC ApplicationXtender Web Access.NET eroom Integration 6.0 Administrator s Guide 300-008-282 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

8380 RPC Return Path Combiner. User s Guide

8380 RPC Return Path Combiner. User s Guide 8380 RPC Return Path Combiner User s Guide Notice Every effort was made to ensure that the information in this manual was accurate at the time of printing. However, information is subject to change without

More information

TopPoint Administrator User's Guide

TopPoint Administrator User's Guide TopPoint Administrator User's Guide LT2153/ 2000 Gilson, Inc. All rights reserved December 2000 Table of Contents 1 Introduction 2 Installation 3 Operation System Requirements... 1-2 Minimum... 1-2 Recommended...

More information

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes

Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Applied Biosystems Attune Cytometric Software version 1.2 Release Notes Customer ( you ) must review these notes prior to installing or operating the Attune Cytometric Software version 1.2 ( Attune Software

More information

Instruction Manual XLComm Data Acquisition Software For XL Series Meters

Instruction Manual XLComm Data Acquisition Software For XL Series Meters Data Acquisition Software For XL Series Meters (XL 15, 20, 25, 30, 40, 50 and 60 meters) 68X090832 Rev. 0 JAN 07 Preface This manual serves to explain the use of the Acquisition Software. The manual functions

More information

Legacy Client Chart (LCC) Installation Guide for Purkinje System

Legacy Client Chart (LCC) Installation Guide for Purkinje System Legacy Client Chart (LCC) Installation Guide for Purkinje System A Guide to Run and Configure the Legacy Client Chart (LCC) Solution For questions about using this guide please contact IMS@aohc.org Table

More information

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements Preface SIMATIC HMI Software SIMATIC HMI Software Programming Manual Overview 1 Range of functions of the RemoteOperate software 2 Hardware and software requirements 3 Installing RemoteOperate 4 Server

More information

Client Installation and User's Guide

Client Installation and User's Guide IBM Tivoli Storage Manager FastBack for Workstations 6.1.2.0 Client Installation and User's Guide SC27-2809-01 IBM Tivoli Storage Manager FastBack for Workstations 6.1.2.0 Client Installation and User's

More information

Manual. Software Protection. TwinCAT 3. Version: Date:

Manual. Software Protection. TwinCAT 3. Version: Date: Manual Software Protection TwinCAT 3 Version: Date: 1.7 2018-10-25 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions... 6 2 Introduction...

More information

HP Video Over Ethernet. User Guide

HP Video Over Ethernet. User Guide HP Video Over Ethernet User Guide 2016 HP Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth

More information

Radiometer AQT90 FLEX Troponin I ERROR CODES

Radiometer AQT90 FLEX Troponin I ERROR CODES Radiometer AQT90 FLEX Troponin I ERROR CODES The meter automatically performs electronic self-tests, i.e. environmental check ensures that the analyser is ready for testing and that consumables have not

More information

Pre-Operation Confirmation Login and Logout Displaying Device Information Downloading and Installing Packages Appendix

Pre-Operation Confirmation Login and Logout Displaying Device Information Downloading and Installing Packages Appendix Professional IS/Standard Client Reference 1 2 3 4 5 Pre-Operation Confirmation Login and Logout Displaying Device Information Downloading and Installing Packages Appendix Read this manual carefully before

More information

USER MANUAL FOR. Nano-Checker 710 THE PIONEER AND CONSISTENT INNOVATOR FOR IN VITRO DIAGNOSTICS

USER MANUAL FOR. Nano-Checker 710 THE PIONEER AND CONSISTENT INNOVATOR FOR IN VITRO DIAGNOSTICS USER MANUAL FOR Nano-Checker 710 THE PIONEER AND CONSISTENT INNOVATOR FOR IN VITRO DIAGNOSTICS Read before initial operation Any questions call our technical support line: TABLE OF CONTENTS Chapter Page

More information

INSTALLATION GUIDE. Trimble AllTrak Software

INSTALLATION GUIDE. Trimble AllTrak Software INSTALLATION GUIDE Trimble AllTrak Software INSTALLATION GUIDE Trimble AllTrak software Version 3.5 Revision A_ENG November 2012 F Trimble Navigation Limited Building Construction 5475 Kellenburger Road

More information

Web Self Service Administrator Guide. Version 1.1.2

Web Self Service Administrator Guide. Version 1.1.2 Version 1.1.2 Web Self Service Administrator Guide Version 1.1.2 Copyright and Trademark Notice Use of the product documented in this guide is subject to your prior acceptance of the End User License Agreement.

More information

Data setting software MEXE02

Data setting software MEXE02 HM-40143 Data setting software MEXE02 OPERATING MANUAL Before Use Thank you for purchasing an Oriental Motor product. This operating manual describes product handling procedures and safety precautions.

More information

IBM Personal Computer. About Your Software Windows NT Workstation 4.0, Applications, and Support Software

IBM Personal Computer. About Your Software Windows NT Workstation 4.0, Applications, and Support Software IBM Personal Computer About Your Software Windows NT Workstation 4.0, Applications, and Support Software IBM Personal Computer About Your Software Windows NT Workstation 4.0, Applications, and Support

More information

Aurora Multi-image System Control Software. User Manual

Aurora Multi-image System Control Software. User Manual Aurora Multi-image System Control Software User Manual Product Information Model: Aurora Controller Software Version: V010200 Release Date: January 18th, 2017 Company OSEE TECHNOLOGY CO., LTD. Contact

More information

Calendar & Buttons Dashboard Menu Features My Profile My Favorites Watch List Adding a New Request...

Calendar & Buttons Dashboard Menu Features My Profile My Favorites Watch List Adding a New Request... remitview User Guide 1 TABLE OF CONTENTS INTRODUCTION... 3 Calendar & Buttons... 3 GETTING STARTED.... 5 Dashboard.... 7 Menu Features... 8 PROFILE.... 10 My Profile... 10 My Favorites... 12 Watch List...

More information

Upgrade Instructions for Version 8.3.3

Upgrade Instructions for Version 8.3.3 Upgrade Instructions for Version 8.3.3 CONTENTS INTRODUCTION... 1 ABOUT THESE UPGRADE INSTRUCTIONS... 1 IMPORTANT NOTES... 1 UPGRADE SUPPORT... 2 PHASE 1: BACKUP YOUR WINSPC DATABASE... 3 PHASE 2: UPGRADE

More information

UNIVERSAL SOFTWARE. Universal Software. Data Sheet

UNIVERSAL SOFTWARE. Universal Software. Data Sheet Universal Software Data Sheet System Requirements: The minimum requirements for using the Software are: 1). Windows XP/Vista/7 2). A minimum of 512 MB RAM 3). 1 GB of hard disk space 4). Microsoft Office

More information

UniPoint System Software User s Guide

UniPoint System Software User s Guide UniPoint System Software User s Guide LT2137 1998 Gilson, Inc. All rights reserved Exercise 3-Creating operations list... 4-22 Create and name operations list... 4-22 Set up steps... 4-23 Identify sample

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide 2013 DataNet Quality Systems. All rights reserved. Printed in U.S.A. WinSPC and QualTrend are registered trademarks of DataNet Quality Systems. All other trademarks

More information

The Plasmon UDO Archive Appliance

The Plasmon UDO Archive Appliance The Plasmon UDO Archive Appliance System Upgrade Guide Document Number: 810-103029-03 Rev A PREFACE Copyright Copyright 2008 by Plasmon. All rights reserved. This item and the information contained herein

More information

Veeam Endpoint Backup

Veeam Endpoint Backup Veeam Endpoint Backup Version 1.5 User Guide March, 2016 2016 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may be reproduced,

More information

KV-SS090. Operating Instructions. Instant Scanning Software. Model No.

KV-SS090. Operating Instructions. Instant Scanning Software. Model No. Operating Instructions Instant Scanning Software Model No. KV-SS090 Thank you for purchasing this Panasonic product. Please read this manual carefully before using this product and save this manual for

More information

1. Introduction Minimum system requirements Basic Concept Server mode

1. Introduction Minimum system requirements Basic Concept Server mode 1. Introduction TC Monitor is software for monitoring and control of Ethernet (TCW) and GSM/GPRS (TCG) controllers. The supported devices are TCW122B-CM, TCW181B-CM, TCW241, TCW220, TCW210-TH and TCG120.

More information

Tofino CMP Installation & Upgrade Guide Tofino CMP Version Tofino Firmware Version 1.7.0

Tofino CMP Installation & Upgrade Guide Tofino CMP Version Tofino Firmware Version 1.7.0 Tofino CMP Installation & Upgrade Guide Tofino CMP Version 1.7.0 Tofino Firmware Version 1.7.0 March 9, 2012 Copyright Information By res Security Inc and MT L Instrum ents While this information is presented

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

Sciex QTrap Operational Steps for Trained Personnel

Sciex QTrap Operational Steps for Trained Personnel Sciex 6500+ QTrap Operational Steps for Trained Personnel Last Updated 09172017 1. If any of the following instructions does not make sense to you or was not covered during your hand-on training, stop

More information

Copyright SolarWinds. All rights reserved worldwide. No part of this document may be reproduced by any means nor modified, decompiled,

Copyright SolarWinds. All rights reserved worldwide. No part of this document may be reproduced by any means nor modified, decompiled, APM Migration Introduction... 3 General Requirements... 3 Database Requirements... 3 Stopping APM Services... 4 Creating and Restoring Orion Database Backups... 4 Creating a Database Backup File with Database

More information

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2

SIMATIC. STEP 7 PLUS TIA Portal Teamcenter Gateway. Introduction to TIA Portal Teamcenter Gateway 1. System requirements 2 Introduction to TIA Portal Teamcenter Gateway 1 System requirements 2 SIMATIC STEP 7 PLUS Basics of working with TIA Portal Teamcenter Gateway 3 Notes on the installation sequence for the TIA Portal and

More information

Perceptive TransForm E-Forms Manager

Perceptive TransForm E-Forms Manager Perceptive TransForm E-Forms Manager Installation and Setup Guide Version: 8.x Date: February 2017 2016-2017 Lexmark. All rights reserved. Lexmark is a trademark of Lexmark International Inc., registered

More information

User Guide. Sage ERP MAS 90 Online

User Guide. Sage ERP MAS 90 Online User Guide Sage ERP MAS 90 Online Sage ERP MAS 90 Online Page 1 Last Updated: November 18, 2011 Table of Contents OVERVIEW... 1 SUPPORT... 1 SAGE ERP MAS 90 ONLINE 24 X 7 CONNECTIVITY SUPPORT... 1 PRODUCT

More information

Version 1.1 March 2017

Version 1.1 March 2017 Version 1.1 March 2017 QuantiFERON -TB Gold Plus Analysis Software (v2.71) Instructional Guide For installation, setup, and use of the QuantiFERON-TB Gold Plus Analysis Software 10595642 QIAGEN, 19300

More information

Equipment Overview: Safety:

Equipment Overview: Safety: PerkinElmer Series 200 HPLC: Operating Procedure 12/2/11 R.C Equipment Overview: This document outlines the basic procedure for using the Sedex light scattering detector and the PE series 200 HPLC system

More information

Working with Mailbox Manager

Working with Mailbox Manager Working with Mailbox Manager A user guide for Mailbox Manager supporting the Message Storage Server component of the Avaya S3400 Message Server Mailbox Manager Version 5.0 February 2003 Copyright 2003

More information

Wholesale Lockbox User Guide

Wholesale Lockbox User Guide Wholesale Lockbox User Guide August 2017 Copyright 2017 City National Bank City National Bank Member FDIC For Client Use Only Table of Contents Introduction... 3 Getting Started... 4 System Requirements...

More information

TestAnyTime User Manual (Imaging) English Version

TestAnyTime User Manual (Imaging) English Version TestAnyTime User Manual (Imaging) English Version 1 User Manual Notes & Notices Thank you for choosing TestAnyTime. This quick start guide will teach you the basics and have you up & running in a few minutes.

More information

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode s SIMATIC Process Control PCS 7 V7.0 PCS 7 OS Process Control Operating Instructions Preface, Contents Additional Documentation 1 Functions of the PCS 7 OS in Process Mode 2 PCS 7 OS Process Mode - User

More information

IMS Client Operation Guide Version V1.1 Date

IMS Client Operation Guide Version V1.1 Date Version V1.1 Date 2015-10-20 About This Document About This Document About This User Manual Please note the following points before using this user manual: This user manual is intended for persons who

More information

QAM-I-102 Operation and Calibration of the Autoanalyzer

QAM-I-102 Operation and Calibration of the Autoanalyzer 1. Applicability and Purpose a. This procedure applies to the operation and calibration of the LaChat Quikchem 8000 Automated Ion Analyzer. An equivalent system may be used with proper revision of this

More information

READ ME FIRST Windows 98/ME/2000

READ ME FIRST Windows 98/ME/2000 READ ME FIRST Windows 98/ME/2000 *DSL Equipment Installation Guide: Alcatel Speed Touch PC *Digital Subscriber Line Part Number: AlcatelPC9x02A Version 1.2-A Table of Contents Follow Steps 1 through 7

More information

Monitor Application for Panasonic TDA

Monitor Application for Panasonic TDA Monitor Application for Panasonic TDA MAP Demo Getting Started Version 1.0 G3 NOVA Communications SRL 28 Iacob Felix, Sector 1, Bucharest, ROMANIA Phone: +1 877 777 8753 www.g3novacommunications.com 2005

More information

User Manual. TSDiag+ Part Number: Version: 5. Date: TSDiag

User Manual. TSDiag+ Part Number: Version: 5. Date: TSDiag User Manual TSDiag+ Part Number: 80860.691 Version: 5 Date: 2011-05-27 Valid for: TSwin.net TSDiag+ 1.5.2 TSDiag+ Version Date Modifications 1 2006-02-13 First edition 2 2006-06-01 New Layout, product

More information

Desktop & Laptop Edition

Desktop & Laptop Edition Desktop & Laptop Edition USER MANUAL For Mac OS X Copyright Notice & Proprietary Information Redstor Limited, 2016. All rights reserved. Trademarks - Mac, Leopard, Snow Leopard, Lion and Mountain Lion

More information

Windows 2000 / XP / Vista User Guide

Windows 2000 / XP / Vista User Guide Windows 2000 / XP / Vista User Guide Version 5.5.1.0 September 2008 Backup Island v5.5 Copyright Notice The use and copying of this product is subject to a license agreement. Any other use is prohibited.

More information