IBHNet. Content: Copyright IBHsoftec GmbH. All rights reserved.

Size: px
Start display at page:

Download "IBHNet. Content: Copyright IBHsoftec GmbH. All rights reserved."

Transcription

1 IBHNet Communication Adaptor Driver for the IBHLink S7, IBHLink S5 ethernet gateway and the IBHsoftec S7-SoftPLC for use with S7 for Windows, the IBHsoftec OPC Server and Simatic STEP 7 Content: 1.0 Introduction 1.1 System requirements 1.2 Installation 2.0 Local operation with a S7-SoftPLC 2.1 Operation in a local area network 2.2 Operation via the Internet 3.0 Configuration of connected PLCs 3.1 IBHLink S7 3.2 IBHLink S5 4.0 Defining access names to identify the PLCs 5.0 Settings within STEP Settings within STEP 7 MicroWin starting with V3.1 SP2 7.0 Using the IBHNet driver with WinCC 8.0 Using the IBHNet driver with the ProTool Pro V6 runtime 9.0 Using the IBHNet driver with WinCC Flexible 10.0 RFC1006 Communication 11.0 Change IBH Net stations with normal user rights 11.1 Registry entries for S7 for Windows access 12.0 Accessing PLC variables 13.0 Troubleshooting 14.0 Technical Data IBH-Link S Technical specifications IBH Link S7 Plus 16.0 Technical specifications IBH Link S7 ++ Copyright IBHsoftec GmbH. All rights reserved. Gesellschaft für Automatisierungstechnik mbh Turmstraße 77 D Beerfelden / Odw. Germany Fon / Fax / Internet: info@ibhsoftec.de Simatic, Step5, Step7, MicroWin, WinCC, ProTool, S7-200, S7-300, S7-400, Profibus and MPI are registered trademarks of Siemens AG, Berlin and Munich. Windows, ActiveX are registered trademarks of Microsoft Cooperation. Excel is a registered trademark of Microsoft Cooperation in the United States and other countries.

2 1.0 Introduction With the IBHNet driver for the IBHLink and the S7-SoftPLC, controllers can be easily programmed and maintained via ethernet using the TCP/IP protocol. Besides programming and variable access, also monitoring the block status of the controller is possible via the IBHNet driver. The IBHNet driver can be used in conjunction with S7 for Windows, with the IBH OPC Server and Simatic STEP 7. Also, the IBHNet driver enables you to gain a direct variable access via standard programming languages like Visual Basic or Delphi. The following PLC controllers can be accessed with the IBHNet driver: - An IBHsoftec S7-SoftPLC, operated on the same PLC. - An IBHsoftec S7-SoftPLC, connected via a local area network, via an Intranet or via the Internet. - Any Simatic S7-300 or S7-400 PLCs, connected via a local area network, via an Intranet or via the Internet. To establish a connection of a Simatic S7-300 or S7-400 PLC with the ethernet network, the communication adaptor IBHLink is required. 1.1 System requirements To install the IBHNet driver on your PC, the following minimum requirements need to be fulfilled by your system: The PC needs to have a 32-Bit Windows Operating System installed. S7 for Windows supports the IBHNet driver starting with version 4.14, the IBH OPC Server starting with version If you are using Simatic STEP 7, it can be used starting with version 5.1. Following operating systems are supported: Windows95 (with Internet Explorer 5.5 and Windows Sockets 2 Update installed), Windows98 (with Internet Explorer 5.5 installed), Windows ME (with Internet Explorer 5.5 installed), Windows NT4 (with Service Pack 6 and Internet Explorer 5.5 installed), as well as Windows 2000 (with Internet Explorer 5.5 installed) and Windows XP. Please also seek for the minimum requirements of your STEP 7 package. If the IBHNet driver is to be used in combination with the communication adaptor IBHLink, please ensure to connect the IBHLink whenever possible directly to the MPI or the Profibus connector of the Simatic S7-300 or S7-400 PLC. If this in some cases may not be possible, it can be necessary to externally supply the IBHLink communication adaptor with a 24V DC supply voltage. IBHsoftec offers special adaptors, if required. The IBHNet network support is integrated in the S7-SoftPLC starting with version If you are using an older version of the SoftPLC, you need to update the SoftPLC, to gain the networking capabilities of the S7-SoftPLC. The used PCs need to have a working network connection via TCP/IP installed. The network names and the IP-Addresses of the used PCs need to be known by the user. Please contact your administrator, if you do not know these numbers. As network hardware any network adaptor that supports Windows and TCP/IP can be used. In a local area network 100 MBit network adaptors and switches should be preferred, in order to gain the best performance. Of course 10 MBit network adaptors can also be used, but they will slow down operation, especially when viewing a block status.

3 1.2 Installation Please make sure to be logged in as administrator, if you are planning to install the IBHNet driver on one of the 32-Bit Windows operating systems Windows NT4, Windows 2000 and Windows XP, since the setup program needs to make entries into the Windows registry during the installation. To install the software, please run the program Setup.exe from the CD and follow the instructions on the screen. Please make sure, that the name of the installation folder does not contain any spaces or other special characters, since the STEP 7 software cannot find the driver in that case. Best is, to keep the old MS-DOS 8.3 convention (8 Characters for the filename, 3 characters as file extension). If STEP 7 is installed on Windows NT4, Windows 2000 and Windows XP, it is required to install the Siemens communication driver for the PC-Adapter (MPI) prior to installing the IBHNet network driver. Upon completion of the installation, please restart your PC. Only a complete restart enables Windows to activate the altered settings. After the installation, the new entry IBHNet can be found in Start-Programs. Run the program IBHNet and IBHLink Settings from the IBHNet menu. With this program, the IP addresses of the connected IBHLinks can be set. The configuration screens of the IBHNet driver can also be accessed from the menu Set PG/PC interface within STEP Local operation with a S7-SoftPLC If the programming software and the IBHsoftec SoftPLC are used on the same PC, the IBHNet driver needs to be installed only on this PC. Enter the IP Address of the local PC in the driver settings, to obtain access to the SoftPLC. 2.1 Operation in a local area network If the programming software and the IBHsoftec SoftPLC are used on different PCs in the same local area network, the IBHNet driver needs to be installed on the PC with the programming software, as well as on the PC with the IBHsoftec SoftPLC. If the IBHLink communication adaptor is used, it is sufficient to install the driver on the PC with the programming software. In order to set up a connection to the PLC in the driver settings, the IP address of the PC with the SoftPLC, respectively the IP address of the connected IBHLink needs to be known by the user.

4 2.2 Operation via the Internet If the programming software and the IBHsoftec SoftPLC are used on different PCs in the same local area network, the IBHNet driver needs to be installed on the PC with the programming software, as well as on the PC with the IBHsoftec SoftPLC. If the IBHLink communication adaptor is used, it is sufficient to install the driver on the PC with the programming software. In order to set up a connection to the PLC in the driver settings, the IP address of the PC with the SoftPLC, respectively the IP address of the connected IBHLink needs to be known by the user. To be sure that the network connection is alive, please make sure that the remote PLC can be reached via the ethernet network. The easiest way do this, is to send a PING <IP-Address> from the DOS-Box. Currently the SoftPLC uses the TCP ports 710, 711 and 712. If your PLC sits behind a firewall, you need to open the appropriate ports for a communication in your firewall-software. Consult your administrator or the documentation of your firewall on how to permit access via certain ports. For future revisions a 16-channel communication is planned. It may be a good idea to already configure the following 32 Ports starting at port 710 (total of 33 ports) in the firewall software. The IBHLink uses the port 1099.

5 3.0 Configuration of connected PLCs For an initial setup of the IP address, the IBH Link must be in the same network segment as the PC with the IBHNet driver software. From Start Programs IBHNet run the program IBHNet and IBHLink Settings. A window as shown below will be displayed: Since no PLC names are defined yet, an empty list will be displayed. Prior to defining a symbolic name for the PLC, an IP address needs to be set for the connected IBHLink. To setup or change a PLC, it is necessary to have at least default user rights. 3.1 IBHLink S7 To do so, please click IBHLink settings.

6 In the list all IBHLink S7 that are connected to the same network segment will show up. If no IP address has been defined yet, it will show up with the address If no IBHLink S7 is shown in the list, it is either not in the same network segment (i.e. cannot be reached with a broadcast) or it is not in configuration mode. In this case please click Search again. A message box as shown below will be displayed: Follow the instructions on the screen and disconnect the IBHLink S7. Re-connect it after 2-3 seconds. 6 seconds after re-connecting it, click OK. The list will be refreshed and the IBHLink S7 will be displayed in the list. In the first 3 minutes after power on the IBHLink S7, the IP address can be set, if the IBHLink S7 is in the same network segment. Select the IBHLink S7 you want to configure from the list and click Settings. If the selected IBHLink S7 has not got an IP address the following window will appear. This dialog also shows up, if IP address and network segment, between PC and IBHLink S7 are not matching.

7 The IP address set in this dialog is just temporary and is exclusively to configure the IBHLink S7 for the first time. If the IP address could set up successfully, the real configuration dialog will be opened. If you will not confirm the following dialog with Save permanently, the IP address will be set, after the next restart of the IBHLink S7 back on the old value ( ). In the following dialog, set the IP address, the subnet mask and if available a gateway address. If no gateway is available in the network, leave these fields empty. Select the data transfer rate of your MPI or Profibus network. If MPI is selected normally the setting is 187,5 kbaud. If the IBHLink is to be used on a Profibus network, it needs to be set to the baudrate, which is configured on the CPU. For a CPU315 2DP the standard setting is 1,5 Mbit/s. Exactly the same data transfer rate as on the CPU needs to be chosen. If the CPU has some weird timing parameters, an advanced profibus parameter screen can be opened to set these parameters. The setting of these parameters can be found in the hardware configuration of the CPU. Since the IBHLink is also a device, which is connected to the MPI/Profibus network, it also has to have an unique MPI/Profibus address. The factory setting is address 0. The Siemens factory setting for a programming device is 0, an Operator panel has the address 1 and a CPU the address 2. Take care to not set a conflicting address for the IBHLink. Also the maximum address in the network, as configured on the CPU and the busprofile MPI/Profibus needs to be selected.

8 After all settings are made, click Save permanently to save the settings in the IBHLinks flash memory. Follow the instructions in the appearing message box to save the settings. Then the configuration of the IP address and the bus is completed. The IBHLink S7 can now be used. The firmware release is also shown in the in the dialog box. By clicking Firmware download the IBHLink S7 can be updated to the newest firmware release. In the installation folder (normally C:\winnt\system32 or C:\windows\system) the file Nlmpi.e11 can be found. This file holds the firmware of the IBHLink communication adaptor. This file needs to be replaced with a file that holds a more recent firmware, if the firmware of the adaptor is to be replaced. If Firmware download is selected, you will be asked to confirm this operation. Clicking Yes will start the update. 3.2 IBHLink S5 For this click the button S5 IBHLink.

9 The list is empty, after a click on the button Suche im lokalem Netz, which means Search on LAN, all IBHLink S5 in the same network segment as your PC shows up. If no IP address is setup, on the list the address appears. If no IBHLink S5 shows up, it is not in the same network segment or not in configuring mode. In this case click on Suche bestimmte Adresse, which means Search given address. The following dialog shows up: Enter the IP address of the IBHLink S5 you want to configure and press suchen, which means search. Select the IBHLink S5 you want to configure and press the button Einstellungen, which means Setup. In the following dialog enter the PLC name (Gerätename), the S5-PG-Port, the S5- Server-Port, the network segment (Subnet-Maske) in which the IBHLink S5 is used and the address of a possibly existing gateway. If there is no gateway available, leave these fields empty. After you entered all your settings, click on OK. The IBHLink S5 now has the new IP address and can be, if your PC is in the same network segment, found as described before in the S5LANMangager. The Firmware of the connected adapter is shown in the dialog field too. After pressing the button Firmware laden, which means Load firmware, the IBHLink S5 can be setup to the updated state. It will open an open data dialog, in it you can search for the new firmware version on your PC. After quitting the dialog with open the firmware update starts.

10 4.0 Defining access names to identify the PLCs By defining a symbolic name for the PLC, it is not necessary to always remember the IP addresses of the CPU. In the next step, we will assign the IBHLinks IP address to a symbolic name for the PLC. From Start Programs IBHNet run the program IBHNet and IBHLink Settings. The screen as shown below will be displayed: In the list, existing stations can be selected. If Change Station is clicked, changes can be applied to definitions of already existing stations. The buttons S7 IBHLink and S5 IBHLink will lead back to the settings of the IBHLink S7/S5, as already discussed in section 3. We assume, that no station has yet been defined. Click New Station to define a new symbolic name. The dialog below will appear:

11 Enter the IP address of the IBHLink S7, IBHLink S5 or the SoftPLC. A selection needs to be made, which type of device it is. Enter a time for a connection timeout. For Step7 a time about 2000 ms has approved, for ProTool CS 4000 ms, for ProTool RT or OPC Servers use 1000 ms. For an S7-300/400 or OP it needs to be chosen, whether the IBHLink S7 is connected to the MPI or Profibus interface. For the S7-200 the PPI interface needs to be selected. Additionally you can choose if you want to test your network connectivity with a ping before you connect. This should be done if you can not be sure about the reliability of your cable connection. If firewalls and/or routers are used, it might be necessary to disable that option. With ProTool RT or OPC Servers Test network connectivity should always be activated. Type a unique name for the PLC and click Apply. The dialog will close upon clicking OK. If S5 IBHLink is selected, the Advanced connection settings will change. Of course the IBHLink S5 can not be used for S7-PG-functions. With the IBHNet drivers it is only possible to read/write data in an S5-PLC via IBHNet object using Delphi, VisualBasic a.s.o.. For using PG functions with S5 software separate drivers are supplied with the IBHLink S5. Enter the port you setup on 3.2 in the field S5-PG-Port.

12 A valid licence need to be entered in order to use the IBHLink S5. The licence information is supplied with the IBHLink S5. To enter the licence information press Enter registration. It will open the following dialog: Attention: Minimum requirements are at least default user rights to complete this step successfully. Enter your name and company. In the field Serial number enter the serial number of the IBHLink S5 in the following format: S5L-XXXXXX-XXXX. Then enter the PIN supplied with your IBHLink S5. If you do not have a valid serial number and/or PIN code, please contact our support. If all information is correct, Add licence will activate itself. To apply your registrations press this button. Attention: Every serial number can be entered only once. With a click on Exit all entered changes are committed, if the dialog is closed by pressing [x] all changes are lost. By clicking Language in the IBH Network settings window, the user interface language can be chosen. The software needs to be restarted to apply the changes. After all names for the PLC have been defined, these can be chosen by selecting the symbolic name, since the IP address is assigned to that name. The dialog below shows, how to select a PLC from STEP 7.

13 5.0 Settings within STEP 7 Once the installation and configuration of the IBHNet driver has been completed successfully, please run your copy of STEP 7. To choose IBHNet as communication driver, select Extras Set PG/PC interface from the STEP 7 menu bar. Alternatively "Set PG/PC interface can also be accessed via the Windows control panel. Starting with Version 1.19 of the IBHNet network driver, the installation of the Siemens driver for the PC-Adapter (MPI) for the Siemens STEP 7 software is not required any more. It simply appears in the list.

14 Select IBHNet as your default communication driver. Click properties to select an already defined PLC or IBH Network Settings to define a new name for a PLC. Confirm your selection by clicking OK. When closing the dialog Set PG/PC interface, STEP 7 will inform you that driver selections have been altered.

15 If you are using an IBHLink, the configuration is now complete. If a SoftPLC in the version 2.x is used, the option TCP/IP (available starting with version 2.10) needs to be selected. To apply the settings, the SoftPLC needs to be restarted.

16 With the current Version 3.x of the SoftPLC the TCP/IP protocols are ON by default. A separate driver installation and/or configuration is not required with the SoftPLC Version 3.x. All required settings are completed. The PLC can now be reached by the Simatic Manager via the IBHLink. Access to the PLC or the SoftPLC will now be performed via TCP/IP.

17 The IBHLink displays the real MPI respectively Profibus address of the PLC. To work with hardware PLC as you would with a PC Adaptor the address of the CPU need to be selected. The SoftPLC always shows the MPI address 2. Work with the Simatic Manager, as you are used to.

18 6.0 Settings within STEP 7 MicroWin starting with V3.1 SP2 After successful installation and configuration of the IBHNet driver, please run your copy of STEP 7 MicroWin. For configuring please select View-Communication Alternatively you can also select Communication from the left bar. If STEP 7 MicroWin is installed on the operating systems Windows NT4, Windows 2000 and Windows XP, the Siemens driver for the PC-Adapter (MPI) needs to be installed. If the PC-Adapter (MPI) is not installed, the IBHNet network driver will not show in the list.

19 Double click on the adaptor, which is displayed as a circuit board to open the dialog Set PG/PC interface. Select IBHNet(PPI) as desired driver. Click Properties to select an already configured PLC or, via IBH Network settings add a new PLC to the list. Save your settings by confirming Ok. All required settings are completed. The PLC can now be reached by the STEP 7 MicroWin software via the IBHLink. Access to the PLC will now be performed via TCP/IP

20 The IBHLink shows the real address of the PLC. In order to work with the PLC, you need to select the PPI address, you want to work with. Then you can work with STEP 7 MicroWin as usual. There is one difference, if the baudrate of the CPU changes, because the SDB has been transferred to the CPU with a different setting in the baudrate. At the end of the transmission, the communication will fail due to the changed baudrate. However, the transmission has been completed successfully. Disconnect the IBHLink from the PLC and terminate STEP 7 MicroWin. After restarting STEP 7 MicroWin first of all, the adaptor has to be set to the new baudrate, prior to any access to the plc. At this pint, it is a good idea to verify all settings and to make sure - confirm these.

21 7.0 Using the IBHNet driver with WinCC To use the IBHNet driver with WinCC, please follow the instructions step by step. - Install WinCC and make sure, the installation was successful. - Now install the IBHNet driver. - Configure the IBHLink and specify the the PLC Names and their connections. - From the control panel open the Set PG/PC interface dialogbox and. select IBHNet (MPI). In the properties dialog choose the previously... configured PLC. - Use some programming software to make sure that the connected PLC. is available. If no programming software is available, the Visual Basic. samples that come with the driver may ba used for testing. The. samples may be found in C:\IBH softec GmbH\IBH_Net\samples. - Now we are sure the PLC is available. Start WinCC and create a new. project. - To make configuration changes, the project must not be active. Make. sure to deactivate the project. - Highlight the Tag Manager and right click. From the context menu,. select Add New Driver.

22 - From the list the driver SIMATIC S7 Protocol Suite.CHN needs to be chosen. - After selecting the driver, the communicatione listed below are. available. Please select the branch MPI.

23 - Before a PLC may be added, the communication parameters need to be set. Right clicking the branch "MPI" opens a context menu. Select System Parameter". - Now set the communication parameters as shown in the two screens below. In the register Unit now the driver IBHNet (MPI) may be chosen. Please make sure to assign a PLC via Set PG-PC interface from the control panel.

24 - To create a PLC, MPI needs to be highlighted again. From the context menu, choose New Driver Connection. - In next dialog a name may be entered for the PLC. WinCC will use this name.

25 - After the PLC has a name, the Properties needs to be opened. Here the MPI address and Rack/Slot nubers of the CPU need to be entered. In the sample a PLC on rack 0, slot 2 with the MPI address 2 is used. Disable the option Send/Receive raw data block.

26 - Now variables for WinCC may be entered. Save your project and verify your settings after restarting the project. In case of questions and/or comments, please contact our product support.

27 8.0 Using the IBHNet driver with the ProTool Pro V6 runtime To use the IBHNet driver with ProTool, please follow the instructions step by step. - Install ProTool and make sure, the installation was successful. - Now install the IBHNet driver. - Configure the IBHLink and specify the the PLC Names and their connections. - From the control panel open the Set PG/PC interface dialogbox and select IBHNet (MPI). In the properties dialog choose the previously configured PLC. - Use some programming software to make sure that the connected PLC is available. If no programming software is available, the Visual Basic samples that come with the driver may ba used for testing. The samples may be found in C:\IBH softec GmbH\IBH_Net\samples. - Now we are sure the PLC is available. Start ProTool and create a new project. - In the newly created project, select the item PLC control. For the protocol Simatic S7-300/400 V6.0 needs to be chosen. The PLC may have any name!

28 - Verify the parameters. - The next screen shows the creation of a boolean variable. For the PLC, select the newly created PLC, here "IBH_Link".

29 - After all settings are made, the ProTool Pro runtime engine should be able to communicate with the PLC. 9.0 Using the IBHNet driver with WinCC Flexible To use the IBHNet driver with WinCC Flexible, please follow the instructions step by step. - Install WinCC Flexible and make sure, the installation was successful. - Now install the IBHNet driver. - Configure the IBHLink and specify the the PLC Names and their connections. - From the control panel open the Set PG/PC interface dialogbox and select IBHNet (MPI). In the properties dialog choose the previously configured PLC.

30 - Use some programming software to make sure that the connected PLC is available. If no programming software is available, the Visual Basic samples that come with the driver may be used for testing. The samples may be found in C:\IBH softec GmbH\IBH_Net\samples. - Now we are sure the PLC is available. Start WinCC Flexible and create a new project. - For the protocol Simatic S7-300/400 needs to be chosen.

31 - After the project is entirely created, verify the parameters in the tree "Communication - Connections". Be sure to disable "Cyclic operation". The next screen shows the creation of a boolean variable. For the PLC, select the newly created PLC, here "Connection_1". - After all settings are made, the WinnCC Flexible runtime should be able to communicate with the PLC.

32 10.0 RFC1006 Communication In order to communicate via RFC1006 with the IBH Link S7 or IBH Link S7 Plus like with a Siemens CP343/443, the "RFC1006 to IBHLink" converter service can be started on the local PC or on a PC in the network. Visualizations (HMI) or other applications, that would normally communicate via RFC1006 with a Siemens CP343/443 can talk to the IBH Link S7 or IBH Link S7 Plus this way. The connection will be established from the HMI to the PC with the "RFC1006 to IBHLink" converter service. The converter translates the requests into the IBH Link S7 or IBH Link S7 Plus protocol and routes them to the PLC. The RFC communication takes place via the TCP Port 102. The Siemens "SIMATIC IEPG Help Service (s7oiehsx.exe)" or the CP emulation of the IBHsoftec S7-SoftPLC may have already occupied this port. Make sure the port is free. Starting the RFC to IBHLink converter via the Start menu enables configuration. Clicking the icon left to the clock in the taskbar opens the configuration dialogs. If configuration is finished, the startup of the service can be set to "Automatic" with the Windows service control manager "Control Panel - Administrative Tools - Services". If started as service, only status dialogs can be opened. To go back to configuration, the Service must be stopped and the converter must be started via the Windows Start menu. To create a connection, click "Create/Edit conection". Connections can be exported and also be imported. The dialog below is used to Create/Edit connections:

33 The RFC1006 communication defines TSAPs to identify connection definitions. Normally those are set up as a combination of Rack/Slot number of the PLC and the HMI. User defined TSAPs are also possible. The assignement between the TSAPs to the connected IBHNet station and its relative PLC must be unique. If unsure which TSAPs are sent by the Visualization/HMI, the user can try to establish a connection from the HMI to the "RFC1006 to IBHLink converter" service. It shows the last requested TSAPS from the HMI in the configuration dialog. Accepting these TSAPs into the current configuration is also possible. The "RFC1006 to IBHLink converter" is ready, as soon as all configuration dialogs were exited with "OK". The status dialog shows the currently established connections and a telegram counter.

34 11.0 Change IBH Net stations with normal user rights Open the Registry Editor with administrative rights: <Start> <Run> regedt32 Navigate to the key HKEY_LOCAL_MACHINE\SOFTWARE\IBH softec GmbH\ and highlight the key IBHNet Right-click and select <Permissions...>: Select <Full Control> for the desired user.

35 11.1 Registry entries for S7 for Windows access Navigate to the key HKEY_LOCAL_MACHINE\SOFTWARE\IBH softec GmbH\S5W- Connect\ and highlight the key S7WILINK Right-click and select <Permissions...>: Select <Full Control> for the desired user.

36 12.0 Accessing PLC variables The IBHNet network driver ships with an object, which allows access to variables of the PLC. This COM-Server can be used in any programming language, such as VisualBasic, Delphi a.s.o.. Its interface name is IIIBHnet. In VisualBasic for instance, it is presented as IBHNet 1.0 Type Library from the menu Project References. To access variables from the PLC the methods and properties listed below are available: Methods of the interface S5 S7 300/400 SoftSPS V2.x SoftSPS V3.x FirstStation(BSTR* pval) X X X X X NextStation(BSTR* pval) X X X X X Connect([in, string] BSTR Station,[in] long X X X X X MPIAdr) Disconnect() X X X X X ReadVal(long typ,long nr,long DBNr,long size, X X X X X long *val) ReadVals(long typ,long nr,long DBNr,long X X X X X size,safearray(unsigned char) vals) WriteVal(long typ, long nr, long DBNr, long X X X X X size, long val) WriteVals(long typ, long nr, long DBNr, long X X X X X size,safearray(unsigned char) vals) PLC_Store() X - PLC_Restore() X - Properties of the interface PLC_Run([out, retval] BOOL *pval) X X - X - PLC_Version([out, retval] long *pval) X - PLC_Cycles([out, retval] long *pval) X - PLC_Stop([in] BOOL newval) X X - X - PLC_Run_OB100([in] BOOL newval) X X - X - PLC_Run_OB101([in] BOOL newval) X X - X - PLC_Terminate([in] BOOL newval) X - PLC_SerialNr([out, retval] BSTR *pval) X - PLC_Name([out, retval] BSTR *pval) X - PLC_Firma([out, retval] BSTR *pval) X - PLC_Mlfb([out, retval] BSTR *pval) X X - X - PLC_CycleAct([out, retval] long *pval) X - PLC_CycleMin([out, retval] long *pval) X - PLC_CycleMax([out, retval] long *pval) X - PLC_JitterMax([out, retval] long *pval) X - PLC_JitterAct([out, retval] long *pval) X - PLC_Load([in] long newval) X - PLC_InitPath([out, retval] BSTR *pval) X - PLC_MemTotal([out, retval] long *pval) X - PLC_MemFree([out, retval] long *pval) X - Station(long Nr, [out, retval] BSTR* pval) - X X X - S7 200 Properties to access Variables MD(long nr, [out, retval] long *pval) MD(long nr, [in] long newval) MW(long nr, [out, retval] long *pval) MW(long nr, [in] long newval) MB(long nr, [out, retval] long *pval) MB(long nr, [in] long newval) M(long nr,long bit, [out, retval] BOOL *pval) M(long nr,long bit, [in] BOOL newval) ED(long nr, [out, retval] long *pval) ED(long nr, [in] long newval) EW(long nr, [out, retval] long *pval) EW(long nr, [in] long newval) EB(long nr, [out, retval] long *pval) EB(long nr, [in] long newval) E(long nr,long bit, [out, retval] BOOL *pval) E(long nr,long bit, [in] BOOL newval) X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

37 AD(long nr, [out, retval] long *pval) AD(long nr, [in] long newval) AW(long nr, [out, retval] long *pval) AW(long nr, [in] long newval) AB(long nr, [out, retval] long *pval) AB(long nr, [in] long newval) A(long nr,long bit, [out, retval] BOOL *pval) A(long nr,long bit, [in] BOOL newval) DD(long DBNr,long nr, [out, retval] long *pval) DD(long DBNr,long nr, [in] long newval) DW(long DBNr,long nr, [out, retval] long *pval) DW(long DBNr,long nr, [in] long newval) DB(long DBNr,long nr, [out, retval] long *pval) DB(long DBNr,long nr, [in] long newval) D(long DBNr,long nr,long bit, [out, retval] BOOL *pval) D(long DBNr,long nr,long bit, [in] BOOL newval) X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X System functions ResetDevice(BSTR device); - X X X X Key_Position([out, retval] long *pval); - X - X - LifeList(BSTR device, VARIANT * - X X X X lifelist); SZ_List(long SZL_ID, long INDEX, VARIANT - X - X - * SZ_List); TerminateDriver(); - X X X X Extended functions and.net Connect_DP(BSTR Station, long DPAdr, long Rack, long Slot) Subnet_Connect_DP(BSTR Station, long MPIStart, long MPIZiel, long RackZiel, long SlotZiel, long Subnet_HH, long Subnet_LL) Subnet_Connect_IP(BSTR Station, long MPIStart, BSTR IPZiel, long RackZiel, long SlotZiel, long Subnet_HH, long Subnet_LL) SubnetConnectH1(BSTR Station, long MPIStart, BSTR H1Ziel, long RackZiel, long SlotZiel, long Subnet_HH, long Subnet_LL) - X X X X ReadDB(long DBNr, VARIANT*DB, long * X X X X X Len) WriteDB(long DBNr, VARIANT DB, long Len) X X X X X DotNetReadVals(long typ, long nr, long X X X X X DBNr, long size, VARIANT * vals) DotNetWriteVals(long typ, long nr, long DBNr, long size, VARIANT vals) X X X X X

38 In the installation folder of the IBHNet driver, samples for Visual Basic 6 can be found. The samples are commented. Samples for other programming languages will follow. Contact our product support to ask for more samples. Following error codes will be returned: Errorcode Description 1 netpcomv.createinstance failed 2 netpcomv.mpi_open failed 3 netpcomv.mpi_connrequest failed 4 connection request to SoftPlc failed 5 netpcomv.mpi_close failed If accessing a variable fails, still an exception will be raised.

39 13.0 Troubleshooting Q: The property dialogs will not show in the Simatic Manager: A: Make sure, that you had administrative rights during installation. After the installation, the PC must be restarted. Make sure to have at least version 5.1 of the Simatic Manager. Run the MS-DOS prompt and go to the installation folder of the IBHNet driver, normally \WINNT\SYSTEM32 or \WINDOWS\SYSTEM. Type the following commands: Regsvr32.exe ibh_netpd.dll Regsvr32.exe ibh_netpdl.dll Regsvr32.exe ibh_netpdldp.dll Regsvr32.exe ibh_netpdlppi.dll Regsvr32.exe ibh_netspl.dll Regsvr32.exe ibhnet.dll As result a message box should show "Dll Register Server Succeeded". Run the program IBH_Netpcom.exe with the option RegServer. Example: C:\Winnt\System32> IBH_NETPCOM.EXE -RegServer No error message should appear. Q: With some older versions of Windows 95, the file IBH_NetPcom.exe can not be correctly registered during installation. A: Your Windows95 lacks the Update for Windows Sockets 2. This can be downloaded from Microsoft free of charge. The filename is: W95ws2setup.exe Q: When accessing a PLC, I get an error message. A: Make sure, that the IP address is correctly entered in the driver settings. If a SoftPLC is used, make sure to have TCP/IP selected in the SoftPLC dialog box. With the command PING <IP address> from the MS-DOS prompt, verify that the IBHLink respectively the PC that holds the SoftPLC can be reached via the Ethernet network. Q: When using a SoftPLC, no Stations are displayed in the Simatic Manager. A: Make sure to have TCP/IP selected in the SoftPLC dialog box. Altering the settings require a restart of the SoftPLC to apply the settings. If no changes are applied, probably the file PLC43.INI in the installation folder of the SoftPLC is write protected. Q: The driver IBHNet does not show in the properties dialog Set PG/PC interface of the STEP7 software. A: Install the driver for the serial adaptor PC-Adaptor (MPI), since this adaptor preinstalls basic functions required by the IBHNet driver. Q: In the properties dialog of the STEP7 software, the no properties for the IBHNet can be opened: A: During the installation pathnames have been used, that do not match the MS-DOS 8.3 convention. The name of the installation path must not have spaces and/or other special characters.

40 Q: During the transfer with ProTool I get the message Server is busy, and it looks as if ProTool hangs. A: The timeout for the IBHLink is set to a too high value. If the timeout is > 4 seconds, this message may show up. Q: The adaptor is connected to the profibus, but there are no online functions possible. A: Verify the timing parameters for the Profibus in the Step7 project. Look at the properties of your profibus and write down the timing parameters. Enter the values read from the Step7 project in the advanced screen of the baudrate settings for the IBHLink adaptor. If there is still no online communication possible, increase the parameter Ttr (Target Rotation Time) as well in the IBHLink and on the CPU by means Technical Data IBH-Link S7 The IBHLink is an ethernet gateway. IBHLink fits in a DSub-housing. It consists of a complete fieldbus master together with a 10/100 MBit/s ethernet interface which uses Auto-Negotiation to determine the speed of the network ist is connected to. Due to the design in a D-Sub housing the IBHLink can be directly attached on the fieldbus-connector of a MPI-capable device. The IBHLink is connected to the next hub or switch by a 3m long STP-cable. To connect the IBHLink directly to a PC, you have to use a cross-over cable. The IBHLink is directly supplied over its MPI interface. The configuration takes place over ethernet. Therefore you have to start IBHNet on a PC which is connected to the same ethernet segment like the IBHLink. A diagnosis channel to the IBHLink is established over a defined TCP/IP port. The configuration is stored in a flash memory inside the IBHLink.

41 Drawing :

42 MPI-Interface pin signal explanation 1 - unused 2 DGND reference potential 3 RxD / TxD-P receive- / send-data-p 4 - unused 5 DGND reference potential 6 - unused 7 VP supply voltage 24 V 8 RxD / TxD-N receive- / send-data-n 9 - unused For the connection of the IBHLink to the MPI interface of a Siemens S7 or another MPI-capable device no connection-cable is needed. The IBHLink is directly attached on the MPI interface of the device. No external power supply is needed, the IBHLink is supplied by the MPI interface. Attention - Due to its compact size, the IBHLink does not have a reverse voltage protection! - Some PLCs may have a temporary error condition on the the MPI/Profibus for the startup period of the internal profibus chip, if the IBHLink is connected in an angular position. If the IBHLink needs to be connected to a PLC that reacts sensitive to this behaviour, the IBHLink must only be connected in powerless state of the PLC. RJ45 connector pin signal explanation 1 TX+ send-data 2 TX- send-data 3 RX+ receive-data 4 - unused 5 - unused 6 RX- receive-data 7 - unused 8 - unused

43 Connection with Hub/Switch IBHLink Hub / Switch PC LED Controls RDY / RUN red Flashing (1 Hz) Bootloader active Flashing fast (10 Hz) Booting, Firmware gets initialized RDY / RUN green On Ready, IP-Address set Flashing irregular no IP-Address or Address exists in the network Flashing fast (10 Hz) Firmware-Update in Progress Link LED On Connection to the ethernet is up Off No connection to the ethernet Technical Data Ethernet-Interface speed interface PROFIBUS-Interface 10 / 100 MBit/s 10 / 100 Base-TX Connector RJ45 RS485, max 12 MBaud PROFIBUS-Interface according to EN supply voltage +24 V / 50 ma operating temperature 0 C - 50 C IP 20 dimensions 65 x 48 x 16 mm weight ~ 140 g with cable

44 15.0 Technical specifications IBH Link S7 Plus Connections The following figure indicates the connections X1, X2 and X3 of the IBH Link S7 Plus. Connection X1 1 2 X2 X3 Description Power Supply Ground 24V Front Connection Cable Connection

45 LED Controls RDY = Ready... yellow Static On Device is ready... yellow Flashing cyclic at 1 Hz Device is in bootloader mode and is waiting for firmware download... yellow Flashing cyclic at 5 Hz Firmware download is in progress... yellow Flashing irregular (*) Hardware or heavy runtime error detected... Off Device has no power supply or hardware defect... (*) 3 times fast at 5 Hz, 8 times between 0,5 Hz and 1 Hz RUN = Communication... green Static On communication is running... green Flashing irregular (*) Power Up: Configuration missing or faulty, device needs commissioning... Off No Communication... (*) 3 times fast at 5 Hz, 8 times between 0,5Hz and 1Hz

46 ERR = Error red Static On Communication error on PROFIBUS... Off No communication error or PROFIBUS STA = Status... yellow On Device is holding the PROFIBUS token and is able to transmit telegrams... yellow Flashing acyclic (**) Device is sharing the PROFIBUS token with other master devices in the PROFIBUS network... Off Device is not configured or has not received the Token permission on the PROFIBUS network... (**) between 0,5 Hz and 100 Hz ACT = Activity... yellow On The device has a link to Ethernet... yellow Flashing The device sends/receive Ethernet frames... Off The Device has no link to Ethernet

47 X2 Ethernet Interface Ethernet pinning at the RJ45 female connector: Pin Signal Meaning 1 TD+ Receive Data + 2 TD Receive Data 3 RD+ Transmit Data + 4 n.c. not used 5 n.c. not used 6 RD Transmit Data 7 n.c. not used 8 n.c. not used Ethernet Connection Data Topology Star Topology Medium 4 x 2 Twisted Pair copper cable Cat 3 (10 MBit/s), Cat 5 (100 MBit/s) Length of cable Transmission rate to the Device or to the next Hub and Switch respectively 10 MBit/s / 100 MBit/s Direct Connection Connection via Hub/Switch

48 Technical data Protection Class IP 20 Cable Connection Cable length 2 m Mounting on DIN rail EN Weight ca. 200 g with Cable Operating Temperature 0 C 50 C Ethernet Interface Transmission rate Interface Connector Dimensions (L x W x H) 10 / 100 MBit/s max. 100 Base-TX potential free RJ45 male connector 65 x 25 x 100 mm PROFIBUS-Interface Transmission rate Power supply Dimensions (L x W x H) RS485, max 12 MBit/s VDC / 100 ma 55 x 16 x 60 mm Attention The IBH Link S7 Plus requires 24 VDC at X1 (see draft section 6.0). Pay attention to polarity.

49 16.0 Technical specifications IBH Link S7 ++ Features: - 16 PC-connections at the same time - 32 MPI / DP-connections at the same time - Automatic Baudrate-detection - RFC Diagnostic LEDs - PG(PU)-Connector - RJ45-Connector - Power supply from the MPI / DP interface - Connection also to passive nodes with power supply via integrated 24V connector Connections Ethernet Interface Ethernet pinout of the RJ45 female connector: Pin Signal Meaning 1 TD+ Receive Data + 2 TD Receive Data 3 RD+ Transmit Data + 4 n.c. not used 5 n.c. not used 6 RD Transmit Data 7 n.c. not used 8 n.c. not used

50 Ethernet Connection Data Topology Medium Length of cable Star Topology 4 x 2 Twisted Pair copper cable Cat 3 (10 MBit/s), Cat 5 (100 MBit/s) 100m to the Device or to the next Hub and Switch respectively Transmission rate 10 MBit/s / 100 MBit/s Direct Connection Connection via Hub/Switch Technical data Ethernet Interface Transmission rate Interface Connector PROFIBUS- Interface Transmission rate 10 / 100 MBit/s max. 100 Base-TX potential free RJ45 female connector RS485, max. 12 MBit/s Attention The IBH Link S7 ++ only requires 24 VDC if not supplied by the PLC. Pay attention to polarity!

Besides PU functions with S5 for Windows also S7-HMI devices can read and write variables from the PLC. The following protocols are supported:

Besides PU functions with S5 for Windows also S7-HMI devices can read and write variables from the PLC. The following protocols are supported: Page 1 of 3 IBH Link S5++ The IBH Link S5++ is a communication adaptor that permits to establish ethernet connections to the standard PU port of a SIMATIC S5 PLC. Under normal circumstances the IBH Link

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways NETL ink gateways Ethernet gateways WLAN gateways High-speed USB gateways ETHERNET NETL ink PRO PoE, PROFIBUS Ethernet gateway FEATURES RFC (ISO on TCP) CPU-to-CPU communication (with S-¹ and S-¹) (POE)

More information

Manual. Profi-S-Link. Document 26/834; Edition EN

Manual. Profi-S-Link. Document 26/834; Edition EN Manual Profi-S-Link Document 26/834; Edition EN03 2013-10-17 Content 0 Content 0 Content 0.1 Document History... 0-2 0.2 About this manual... 0-2 0.3 Brands and trademarks... 0-2 0 1 Quickstart 1.1 Summary...

More information

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014 FAQ 03/2014 Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - http://support.automation.siemens.com/ww/view/en/88633853 This entry is from the Siemens Industry Online

More information

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

SIMATIC NET. S7 CPs for Industrial Ethernet CP Version 3 or later (Firmware version V2.2) for SIMATIC S LED displays.

SIMATIC NET. S7 CPs for Industrial Ethernet CP Version 3 or later (Firmware version V2.2) for SIMATIC S LED displays. SIMATIC NET S7 CPs for Industrial Ethernet CP 443-1 6GK7 443 1EX11 0XE0 for SIMATIC S7 400 Version 3 or later (Firmware version V2.2) LED displays Mode selector MAC address label TP interface: AUI/ITP

More information

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25

Manual. VIPA Accessories USB-MPI adapter 950-0KB31. Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 Manual VIPA Accessories USB-MPI adapter 950-0KB31 Order No.: VIPA HB158E_PC-AG Reference: RE_950-0KB31 Rev. 08/25 This manual is relevant for: Product Order number as of state: HW SW USB-MPI adapter VIPA

More information

DGH A3000 Configuration Guide For use with DGH Modules

DGH A3000 Configuration Guide For use with DGH Modules DGH A3000 Configuration Guide For use with DGH Modules Revision Date: 12/07/05 Version: 1.00 Contact Information: http://www.dghcorp.com Ph: (603) 622-0452 Fax: (603) 622-0487 Mailing Address: DGH Corporation

More information

modunet292: novanet-ethernet interface

modunet292: novanet-ethernet interface SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

S5-PCLink. Ethernet-Gateway for Siemens S5 Controller. User Manual. Edition 1 /

S5-PCLink. Ethernet-Gateway for Siemens S5 Controller. User Manual. Edition 1 / S5-PCLink Ethernet-Gateway for Siemens S5 Controller User Manual Edition 1 / 2006-11-17 STEP, Protool and SIMATIC are trademarks of Siemens AG. MS-DOS and Windows are trademarks of Microsoft Corporation.

More information

Siemens Distributor SIMATIC. WinAC MP for MP370 V3.1. Preface, Contents. Product Overview. Transferring WinAC MP to the Multi Panel

Siemens Distributor SIMATIC. WinAC MP for MP370 V3.1. Preface, Contents. Product Overview. Transferring WinAC MP to the Multi Panel Preface, Contents SIMATIC WinAC MP for MP370 V3.1 User Manual Product Overview Transferring WinAC MP to the Multi Panel Developing and Downloading a STEP 7 Project for WinAC MP Controlling Your Process

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

User s Manual. INAT echolink Serial / Industrial Ethernet- Converter. Manual-Version e

User s Manual. INAT echolink Serial / Industrial Ethernet- Converter. Manual-Version e User s Manual Serial / Industrial Ethernet- Converter Manual- 2 Copyright The contents of this manual an the related configuration software are the property of the INAT GmbH. This material is subject to

More information

Getting Started. OPC Server Manual Version ek

Getting Started. OPC Server Manual Version ek INAT Industrial Networks for Automation Technology Getting Started OPC Server Manual Version 0207-004ek C OPYRIGHT The contents of this manual and the related software are the property of INAT GmbH. This

More information

SINAUT ST7 station control system SIMATIC NET. Industrial Remote Communication - TeleControl SINAUT ST7 station control system.

SINAUT ST7 station control system SIMATIC NET. Industrial Remote Communication - TeleControl SINAUT ST7 station control system. Preface Properties of the SINAUT components 1 SIMATIC NET Industrial Remote Communication - TeleControl System Manual Network structures and topologies 2 Installation guide 3 Installing and putting a TIM

More information

FAQ Communication over PROFIBUS

FAQ Communication over PROFIBUS FAQ Communication over PROFIBUS Communication over PROFIBUS FAQ Table of Contents Table of Contents... 2 Question...2 How do I configure a PC station as DP Slave interfacing to a S7 station (as DP Master)

More information

Profibus Gateway 3E V Technical Bulletin

Profibus Gateway 3E V Technical Bulletin Profibus Gateway 3E V1.0.0 Technical Bulletin TECHNICAL BULLETIN 2 Profibus Gateway 3E Liability for errors and misprints excluded. V1.0.0en/23.06.16 TECHNICAL BULLETIN Profibus Gateway 3E V1.0.0en/23.06.16

More information

CP ADVANCED. Function

CP ADVANCED. Function CP 343-1 ADVANCED Function The CP 343-1 Advanced independently handles data traffic over Industrial Ethernet. The module has its own processor and can be put into service directly using the unique preset

More information

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO DeviceNet/PROFIBUS-DP Adapter - User Manual REV 4.0 SiboTech Automation Co., Ltd. Technical Support: +86-21-5102 8348 E-mail:gt@sibotech.net Table of Contents 1 ABOUT THIS DOCUMENT...2 1.1 GENERAL... 2

More information

Serial to Ethernet Converter

Serial to Ethernet Converter Serial to Ethernet Converter User s Manual Version 1.1 2004 Infosystem Technology Corporation Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Infosystem

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4 SIMATIC NET S7-CPs for PROFIBUS Manual Part B4 CP 443-5 Extended for PROFIBUS 6GK7 443-5DX04-0XE0 Version 1 or higher (Firmware Version V6.1 or higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs

More information

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS.

FAQ 03/2014. How do I go online? SIMOTION & SINAMICS. FAQ 03/2014 How do I go online? SIMOTION & SINAMICS http://support.automation.siemens.com/ww/view/de/22016709 This article is taken from Siemens Industry Online Support. The terms of use specified there

More information

CP BACNET Function

CP BACNET Function CP 343-1 BACNET Function The CP 343-1 BACnet independently handles data traffic via Industrial Ethernet and BACnet protocol. The module has its own processor and can be put into service directly using

More information

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation HART / EtherNet/IP Gateway GT200-HT-EI V 1.0 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features... 4 1.3 Technical

More information

EasyConnect PROFIBUS-Connector, 90

EasyConnect PROFIBUS-Connector, 90 32 Catalog 10 Bus Connectors Repeater Active Dropcable Terminal Block DP/DP Coupler Ethernet Gateways OPC Server Systeme Helmholz GmbH 91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135 7380-110

More information

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW Version 2 en ab FW 1.02 Quick Start Guide PN/CAN Gateway Layer 2 www.helmholz.de Content 1. Introduction 3 2. Preparation of the PN/CAN Gateway 3 3. Configure PN/CAN Gateway 4 4. PN/CAN Gateway settings

More information

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214PG (214-2BE03) Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:

More information

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec PROFIBUS DP / Modbus TCP Gateway EP-321MP User Manual REV 1.2 Sibotech Automation Co., Ltd Technical Support: 021-5102 8348 E-mail:support@sibotech.net Catalog 1 Product Overview... 4 1.1 General...4 1.2

More information

SIMATIC. Windows Logic Controller (WinLC) Preface, Contents. Product Overview 1. Setting Up WinLC Software 2

SIMATIC. Windows Logic Controller (WinLC) Preface, Contents. Product Overview 1. Setting Up WinLC Software 2 SIMATIC Windows Logic Controller (WinLC) User Manual Preface, Contents Product Overview 1 Setting Up WinLC Software 2 Connecting SIMATIC Client Software to WinLC 3 Running the WinLC Software 4 Operations

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH485Ex1 Doc No: PH485Ex1-UM-001 #1 RS-485 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning SIMATIC NET S7-CPs for PROFIBUS Configuring and Commissioning Manual Part A - General Application Preface, Contents Communication over S7-CPs 1 Characteristics of the PROFIBUS CPs 2 NCM S7 for PROFIBUS

More information

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet VIPA CPU 214NET PG (214-2BT13) Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active

More information

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3 SIMATIC Component based Automation - WinLC PN Addendum to WinAC Basis V3.0 Manual Foreword 1 Introduction to CBA and WinAC PN 2 Routing with WinLC PN 3 Installing WinLC PN 4 Commissioning WinLC PN 5 Notes

More information

https://support.industry.siemens.com/cs/ww/de/view/

https://support.industry.siemens.com/cs/ww/de/view/ Operating System Update (OS Update) ProSave https://support.industry.siemens.com/cs/ww/de/view/19701610 Siemens Industry Online Support Siemens AG 2017 All rights reserved This entry originates from Siemens

More information

Gateway 1400 Reference Manual

Gateway 1400 Reference Manual Profibus-DP Gateway 1400 Reference Manual Copyright All Rights Reserved. No part of this document may be copied, reproduced, republished, uploaded, posted, transmitted, distributed, stored in or introduced

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

SSE232-LE Serial Server- User s Manual

SSE232-LE Serial Server- User s Manual www.exemys.com Rev.6 1 Products are in constant evolution to satisfy our customer needs. For that reason, the specifications and capabilities are subject to change without prior notice. Updated information

More information

Revision History. Version Date Changes Description of bridge mode settings via web interface Initial version

Revision History. Version Date Changes Description of bridge mode settings via web interface Initial version MANUAL ANAGATE CAN ANALYTICA GmbH Vorholzstrasse 36 Tel. +49 721 35043-0 E-mail: info@analytica-gmbh.de D-76137 Karlsruhe Fax: +49 721 35043-20 WWW: http://www.analytica-gmbh.de 1 2004-2006, Analytica

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

FAQ Communication over IE

FAQ Communication over IE FAQ Communication over IE Communication over Industrial Ethernet FAQ Table of Contents Table of Contents... 2 Question...2 How do I configure a PC station as PROFINET IO controller interfacing to a S7

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

SINAUT ST7. SINAUT ST7cc Control Center A I. Manual. Introduction to ST7cc. Installation. Preparation. Working with ST7cc Config

SINAUT ST7. SINAUT ST7cc Control Center A I. Manual. Introduction to ST7cc. Installation. Preparation. Working with ST7cc Config Introduction to ST7cc 1 Installation 2 SINAUT ST7 SINAUT ST7cc Control Center Manual Preparation Working with ST7cc Config 3 4 ST7cc Config with EXCEL 5 Valid for ST7cc Server 6 Product Software Version

More information

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522 4.2 ISDN devices 502 506 512 522 532 536 542 552 556 Voltage VDC 24 Current ma (24V) 60 60 70 90 90 100 80 100 110 Protection class (IP) 20 Range of use Dry Surroundings Temperatures (Plant) 0 50 C Temperatures

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en.

Quick Start Guide PROFINET Switch 4/8-port. Version. 1en. Quick Start Guide PROFINET Switch 4/8-port Version 1en www.helmholz.de Contents 1. Introduction 3 2. Preparing the PROFINET switch 4 3. Project planning for PROFINET switch 4 4. Setting the port properties

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Modbus Server Fidelio IP User Manual r1 eng Issue Date: 10/04/2014 Intesis Software S.L. All Rights Reserved. Information in this document is subject to change without notice. The software described

More information

X-Series System Manual Part 7: Interfaces and data communication

X-Series System Manual Part 7: Interfaces and data communication X-Series System Manual Part 7: Interfaces and data communication Version check: Version No. Date Version 3.1 April 2012 Version 3.0 April 2011 Version 2.0 October 2007 Version 1.0 March 2006 Mettler-Toledo

More information

RTU560 Remote Terminal Unit Connections and Settings

RTU560 Remote Terminal Unit Connections and Settings Remote Terminal Unit Connections and Settings Communication Unit 560CMG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CMG10 1KGT 150 645 Operation

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Why is it Not Possible to Transfer the HMI Configuration to the Panel? Ethernet Connection Subhead https://support.industry.siemens.com/cs/ww/en/view/88633853 Siemens Industry Online Support Copyright

More information

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB Automation Technology > Automation Systems > Industrial Automation Systems SIMATIC > Distributed I/Os SIMATIC ET200 > ET 200 systems for the cabinet > ET 200S > Interface modules > Interface modules with

More information

Date Revision Change(s) First version

Date Revision Change(s) First version Revision overview Revision overview Date Revision Change(s) 04.06.2015 0 First version Copyright 2015 Indu-Sol GmbH We reserve the right to amend this document without notice. We continuously work on further

More information

Modbus TCP/RTU Gateway

Modbus TCP/RTU Gateway Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional

More information

Revision History. Version Date Changes Error in PIN description SPI jack Initial version

Revision History. Version Date Changes Error in PIN description SPI jack Initial version MANUAL ANAGATE SPI ANALYTICA GmbH Vorholzstrasse 36 Tel. +49 721 35043-0 E-mail: info@analytica-gmbh.de D-76137 Karlsruhe Fax: +49 721 35043-20 WWW: http://www.analytica-gmbh.de 1 2004-2006, Analytica

More information

S7-200 PPI Monomaster Remote connection How To

S7-200 PPI Monomaster Remote connection How To ewon Application User Guide AUG 017 / Rev 1.0 You Select, We Connect S7-200 PPI Monomaster Remote connection How To Content The purpose of this guide is to explain in a few steps how to configure your

More information

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA)

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA) Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA) MODULE E07 Diagnosis on the PROFINET with IO Controller CPU 315F-2 PN/DP, Switch SCALANCE X208 and IO Device ET

More information

SIMATIC. Windows Automation Center WinAC Basis V4.1. User Manual. Version: 05/2004 A5E Siemens Automation

SIMATIC. Windows Automation Center WinAC Basis V4.1. User Manual. Version: 05/2004 A5E Siemens Automation SIMATIC Windows Automation Center WinAC Basis V4.1 User Manual Version: 05/2004 A5E00340325-01 Siemens Automation Copyright and Safety Notification This manual contains notices that you should observe

More information

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA) SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA) Siemens Automation Cooperates with Education TIA Portal Module 060-010 PROFIBUS with Master CPU 315F-2 PNDP

More information

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted

SITRAIN. Introduction TIA Portal. Siemens AG All rights reserved. Unrestricted Introduction TIA Portal Unrestricted Siemens AG 2011. All rights reserved. Orange juice factory TIA-PRO1 / Introduction TIA Portal Page 2 Siemens AG 2011 HMI System HMI and SCADA TIA-PRO1 / Introduction

More information

Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366

Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366 Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366 AS-i master profile: M4 Firmware: from version RTS 3.0 onwards Target: from V.15 onwards for CoDeSys from

More information

SIMATIC. Windows Automation Center. WinAC Basis. Overview. Preface. Product Overview 1. Installing the Components of. WinAC Basis

SIMATIC. Windows Automation Center. WinAC Basis. Overview. Preface. Product Overview 1. Installing the Components of. WinAC Basis SIMATIC Windows Automation Center WinAC Basis Overview Preface Product Overview 1 Installing the Components of WinAC Basis Getting Started with WinAC Basis 3 Using the Tool Manager 4 2 Manual Appendix

More information

Tech Note 220 Configuring the S7 Server for MPI or Profibus Communications for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP5613 Card

Tech Note 220 Configuring the S7 Server for MPI or Profibus Communications for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP5613 Card 페이지 1 / 12 Tech Note 220 Configuring the S7 Server for MPI or Profibus Communications for Windows NT 4.0 to Access S7-400 PLCs via the Siemens CP5613 Card All Tech Notes and KBCD documents and software

More information

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng IntesisBox Modbus Server KILSEN KSA-7xx User s Manual 08/2013 r1.2 eng Intesis Software S.L. 2013 All rights reserved. Information in this document is subject to change without notice. The software described

More information

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation

HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation HART/ Modbus TCP Gateway GT200-HT-MT User Manual V 1.2 REV A SST Automation E-mail: SUPPORT@SSTCOMM.COM WWW.SSTCOMM.COM Catalog 1 Product Overview... 4 1.1 Product Function...4 1.2 Product Features...

More information

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA) SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA) Siemens Automation Cooperates with Education TIA Portal Module 070-010 PROFINET with IO Controller CPU 315F-2

More information

Modular Control System KS VARIO

Modular Control System KS VARIO Modular Control System KS VARIO Interface Description PROFINET 9499 040 94211 valid from: 1/2015 SIMATI is a registered trademark of Siemens AG STEP is a registered trademark of Siemens AG is a registered

More information

Date Revision Change(s) First version Firmware Update 1.5

Date Revision Change(s) First version Firmware Update 1.5 Revision overview Revision overview Date Revision Change(s) 04.06.2015 0 First version 30.06.2016 1 Firmware Update 1.5 Copyright 2016 Indu-Sol GmbH We reserve the right to amend this document without

More information

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve

More information

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide

BNI PNT Z015. IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide BNI PNT-502-105-Z015 IP67 Modules 4 IO-Link/In-/Outputs,12 In-/Outputs User s Guide Content 1 Notes 3 1.1. About this guide 3 1.2. Structure of the guide 3 1.3. Typographical Conventions 3 Enumerations

More information

Document: S7 Driver Configuration. Setting up the S7 driver to communicate with Siemens Hardware (S7-300/400 Series) using CP

Document: S7 Driver Configuration. Setting up the S7 driver to communicate with Siemens Hardware (S7-300/400 Series) using CP Document: S7 Driver Configuration S7 Driver Configuration Setting up the S7 driver to communicate with Siemens Hardware (S7-300/400 Series) using CP 5613/CP5611, CP1613 cards and Standard Network Adapter

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU315F-2 PN/DP, CENTRAL PROCESSING UNIT WITH 512 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

More information

BCOM-USB Device. User Manual.

BCOM-USB Device. User Manual. BCOM-USB Device User Manual www.kalkitech.com Version 2.1.2, December 2017 Copyright Notice 2017 Applied Systems Engineering, Inc. All Rights reserved. This user manual is a publication of Applied Systems

More information

SERIAL TO ETHERNET CONVERTER E-P User Manual

SERIAL TO ETHERNET CONVERTER E-P User Manual SERIAL TO ETHERNET CONVERTER E-P132-100 User Manual 1 Table of Contents Introduction... 4 Overview.. 5 Package Checklist 6 Block Diagram 7 Product Features...8 Product Specifications 9 Converter Description

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual

CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual 1/36 CVIC II - CVIL II - CVIR II - MULTICVIL II - Memory Mapping - Manual N - Copyright 2011, St Herblain France All rights reserved. Any unauthorized use or copying of the contents or part thereof is

More information

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway

GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway GW-7238D J1939 to Modbus TCP Server / RTU Slave Gateway User s Manual www.icpdas.com 1 Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one

More information

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E09. PROFINET with 2x CPU 315F-2 PN/DP

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E09. PROFINET with 2x CPU 315F-2 PN/DP Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE PROFINET with 2 x CPU 315F-2 PN/DP T I A Training Document Page 1 of 45 Module This document has been

More information

SK CU4-PNT-C Part number:

SK CU4-PNT-C Part number: SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

RTU560 Connections and Settings DIN Rail RTU 560CIG10

RTU560 Connections and Settings DIN Rail RTU 560CIG10 Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail

More information

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode Global FW Rulesets SIMATIC NET Industrial Ethernet Security Preface 1 Firewall in standard mode 2 Firewall in advanced mode 3 Configuring a VPN tunnel 4 Configuring remote access via a VPN tunnel 5 Getting

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 1 MB WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

More information

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS TELESERVICE Teleservice with TS Adapter IE Teleservice with TS Adapter II Page 1864 Mar 2008 Siemens ITS For performing remote maintenance over the telephone network: A PG/PC with an Engineering Tool installed,

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU 315-2 PN/DP, CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY

More information

ecov-110 User s Manual (V0.9f_Eng)

ecov-110 User s Manual (V0.9f_Eng) ecov-110 User s Manual (V0.9f_Eng) 1. Product Introduction 2. Windows Utility 3. Web Console 4. Command Mode 5. Connection Test Appendix A. ecov-110 Firmware Upgrade Appendix B. ecov-110 Serial Advanced

More information

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual Third Edition, Dec. 2008 www.korenix.com Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

More information

High-response valve with integrated digital axis controller (IAC-R) and clocksynchronized PROFIBUS DP/V2 (PROFIdrive profile)

High-response valve with integrated digital axis controller (IAC-R) and clocksynchronized PROFIBUS DP/V2 (PROFIdrive profile) 4WRPNH.../24F.. High-response valve with integrated digital axis controller (IAC-R) and clocksynchronized PROFIBUS DP/V2 (PROFIdrive profile) Commissioning instructions for WinHPT on Siemens SINUMERIK

More information

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual Motors Automation Energy Transmission & Distribution Coatings Profibus DP SRW 01 User s Manual Profibus DP User s Manual Series: SRW 01 Firmware Version: V6.0X Language: English Document Number: 10000521541

More information

General information. Supply voltage. Input current

General information. Supply voltage. Input current Data sheet SIMATIC S7-300 CPU319F-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT

More information

Provisional documentation, Profibus-DP and Profi-S-IO Contents

Provisional documentation, Profibus-DP and Profi-S-IO Contents Provisional documentation, Profibus-DP and Profi-S-IO Contents 1 INTRODUCTION 3 2 CONFIGURATION 3 2.1 INTERFACES 3 2.2 POSSIBLE COMBINATIONS 3 2.2.1 Overview 3 2.2.2 Configuration details 4 2.2.3 Recommended

More information

RS232+LAN INTERFACE USER MANUAL

RS232+LAN INTERFACE USER MANUAL LAN202 USER MANUAL May 2006 - Ed. 1 English 1 SUMMARY 1 LAN202 module... 3 1.1 Connections via Ethernet... 4 2 Configuration... 5 2.1 Saving and protection of the configuration... 8 3 Virtual COM... 9

More information

The possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005.

The possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005. 5.2 CP260 5.2.1 General Information The CPU is inserted in the main rack directly next to the power supply module. It requires two slots. Only the status LEDs can be seen with the module door closed. The

More information

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld FACTORY AUTOMATION MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld R With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

PROFIBUS DP/CAN Gateway PCA-100. User Manual

PROFIBUS DP/CAN Gateway PCA-100. User Manual PCA-100 REV 4.0 SiboTech Automation Co., Ltd. Technical Support: 021-5102 8348 E-mail: support@sibotech.net Catalog 1 Introduction... 2 1.1 About This Instruction... 2 1.2 Copyright... 2 1.3 Related Products...

More information