1 English VIDEOKIT VK8K/6358 SERIES 6 Wire bus one way, two way videokit VK8K VK8KC 6358 Installation handbook EN V 3.4 3/08/6 We recommend This equipment is installed by a Competent Electrician, Security or Communications Engineer.
2 Index Introduction... System components and available versions... 3 General directions for installation... 5 Troubleshooting guide... 6 Art Speaker unit... 7 Art Art Digital codelock module Series Surface and flush mounting door station installation... Art " colour display videophone Series Videophone wall mounting instructions... 7 Installation diagrams... 8 Introduction The VK8K Series is a new range of videokits that use the 8000 Series external door station and the Art videophone which is specific for this range of videokit and VK4K videokit. The camera/audio unit is the size of a one point five 8000 Series module and is available in either flush (VK8K) or surface (VK8K-S) mounting versions. As a result of using microprocessor technology in the door panel and videophone, a number of additional features have been added to enhance the operation of the videokits and give greater feedback to the visitor and user. Disability friendly, acoustic signals from the door panel to inform the visitor of call status (call made, ringing, speak, door open). Two methods of operating the electric lock:- ) Dry contact relay, ) capacitor discharge circuit. Connections for a push to exit button. Programmable door open and conversation time. Expandable to 4 entrance panels (requires an additional relay Art. 506N for each entrance panel). Facility for the connection of a codelock Art Programmable number of call tone rings from to a maximum of 8. Input for local door bell push button. Door open status LED (additional wire required from the door to the videophone). Programmable timed privacy function from 5 minutes to a maximum of 8 hours. Videophones can have a maximum of two additional audio telephone handsets connected in parallel. Up to 4 videophones can be connected in parallel, all with intercommunication facility. Camera recall on all systems, with selective recall on systems with multiple entrances. Door panel camera can be adjusted horizontally and vertically (0 degrees) EN - V 3.4-3/08/6
3 System components and available versions VK8K/6358 Colour videokit. OUTDOOR STATI INDOOR STATI Videophone Art pag. 4 Camera unit Art pag ACCESSORIES Power supply Art. 850K pag Flush Mounting Surface Mounting Fig. - VK8K/6358 components (measures in mm) E WAY VERSIS VK8K-/ flush mounting Outdoor station composed of: Art /DN/C: button camera unit Art. 8855: Flush mounting box Art. 8875: Rainshield VK8K-S/ surface mounting Outdoor station composed of: Art /DN/C: button camera unit Art. 8885: Surface mounting box Colour videophone Art Colour videophone Art Power supply Art. 850K Power supply Art. 850K TWO WAY VERSIS VK8K-/ flush mounting Outdoor station composed of: Art /DN/C: buttons camera unit Art. 8855: Flush mounting box Art. 8875: Rainshield VK8K-S/ surface mounting Outdoor station composed of: Art /DN/C: buttons camera unit Art. 8885: Surface mounting box Colour videophones Art Colour videophones Art Power supplies Art. 850K Power supplies Art. 850K EN - V 3.4-3/08/6
4 System components and available versions VK8KC/6358 Colour videokit plus a codelock module. OUTDOOR STATI INDOOR STATI Videophone Art pag. 4 Camera unit Art pag. 7 Codelock module Art pag ACCESSORIES Power supply Art. 850K pag. 5 Fig. - VK8KC/6358 components (measures in mm) Flush Mounting Surface Mounting E WAY VERSIS VK8KC-/ flush mounting Outdoor station composed of: Art /DN/C: button camera unit Art. 8800: Codelock module Art. 8857: Flush mounting box Art. 8877: Rainshield VK8KC-S/ surface mounting Outdoor station composed of: Art /DN/C: button camera unit Art. 8800: Codelock module Art. 8887: Surface mounting box Colour videophone Art Colour videophone Art Power supply Art. 850K Power supply Art. 850K TWO WAY VERSIS VK8KC-/ flush mounting Outdoor station composed of: Art /DN/C: buttons camera unit Art. 8800: Codelock module Art. 8857: Flush mounting box Art. 8877: Rainshield VK8KC-S/ surface mounting Outdoor station composed of: Art /DN/C: buttons camera unit Art. 8800: Codelock module Art. 8887: Surface mounting box Colour videophones Art Colour videophones Art Power supplies Art. 850K Power supplies Art. 850K EN - V 3.4-3/08/6
5 General directions for installation CNECTI TO MAINS The system must be installed according to national rules in force, in particular we recommend to: Connect the system to the mains through an all-pole circuit breaker which shall have contact separation of at least 3mm in each pole and shall disconnect all poles simultaneously; The all-pole circuit breaker shall be placed for easy access and the switch shall remain readily operable. POWER SUPPLY INSTALLATI Remove the terminal side covers by unscrewing the retaining screws; Fix the power supply to a DIN bar or directly to the wall using two expansion type screws; Switch off the mains using the circuit breaker mentioned above and then make the connections as shown on the installation diagrams; Check the connections and secure the wires into the terminals; Replace the terminal covers and fix them using the relevant screws; When all connections are made, restore the mains. CABLE SIZE Video connections and Audio connections must be wired in twisted pair: pair the video lines (terminals/signals V and V ), pair the audio lines (terminals /signals and ). Power supply Distance Up to 40mt wires Ø mm 0mt max Suggested cables type CAT5/CAT6 FTP/UTP AWG4 Videophone BROWN WHITE/BROWN BLUE WHITE/BLUE ORANGE WHITE/ORANGE GREEN WHITE/GREEN Up to 40mt +V * * V V * Couple the two wires to double the section. Outdoor station Power supply Distance Up to 50mt From 50 to 00mt From 00 to 00mt wires Ø mm 0mt max Suggested cables type Belden 9746 or equivalnet 4 pair (8 cores) 0.35mm AWG - 48Ω/Km Belden 9690 or equivalnet 3 pair (6 cores) 0.8mm AWG8-9.Ω/Km Belden 957 or equivalnet 4 pair (8 cores) 0.8mm AWG8-9.Ω/Km Videophone "+V" and " " Ø 0.35mm "" and "" Ø 0.35mm Twisted pair "V" and "V" Ø 0.35mm Twisted pair Up to 50mt "+V" and " " Ø 0.75mm "" and "" Ø 0.5mm Twisted pair "V" and "V" Ø 0.5mm Twisted pair from 50 to 00mt "+V" and " " Ø.5mm "" and "" Ø 0.75mm Twisted pair "V" and "V" Ø 0.75mm Twisted pair from 00 to 00mt +V V V Outdoor station +V V V Outdoor station +V V V Outdoor station EN - V 3.4-3/08/6
6 Troubleshooting guide In case of system failure, try the following preliminary checks: Check that the cables are connected as shown in the installation diagram and that the cables are firmly fixed into the relevant terminals; Check that the mains voltage is available on terminals 30Vac (or 7Vac) and 0 of the power transformer Art. 850K; Check the 4Vac voltage output of the power transformer Art. 850K. If this voltage is not available it could be the,6a fuse, in this case remove the mains voltage, remove possible short-circuits or overload sources then replace the fuse with an equal or equivalent one. Check that the voltage between the terminals + and - of the speaker unit is between 6 and 0Vdc. If the problem persists try the tests in the following table or contact technical support. SYMPTOM CAUSE SOLUTI The door station is not able to call the extension (the bell LED is switched on for seconds): Wrong connection between door station and the videophone Cable size too small. Programmed videophone address incorrect. You have changed the videophone address without power down the system. External call works but when answered Cable size too small. the communication fails: During the conversation it is not possible Cable size too small. to open the door: During the conversation it is not possible to open the door but the key LED on the door station switches on for the programmed time: Incorrect position of J jumper. Electric lock wires unconnected or in short. Wrong electric lock type. Check the 6 common wire connections especially wire (speech line/data). Increase cable size or double up using two wires for each connection. Check videophone address on dip-switches. Power down the system then power up again to detect the new videophone address. Increase cable size or double up using two wires for each signal. Increase cable size or double up using two wires for each signal. Check J position on the door station. Check connection. Check that the electric lock type (ac or dc) is suitable for the J position chosen. Speech only from outside to inside: Wire broken or in short. Check connection of wire. Low volume of speech: Volume trimmers of door station require Adjust the trimmers until the required adjustment. volume is reached. Noise over the speech line during the conversation: Camera recall service does not work: Intercommunicating call does not work: The video shown on the monitor is of a bad quality and the image is distorted or double Local call does not work: The 6 common wires are cabled together with 30 or 380Vac power lines. The 6 common wires are cabled together with 4Vac videophone power supply wires. Camera recall button pressed for a number of times different from the ID of the door station to be switched on. Key button pressed for a number of times different from the videophone address value. V,V signals unconnected, reversed or shorted. The switches of the two way dip-switch are not both in position. V,V of the last Art. 36N (if present) not closed with 75 Ohm resistor. Separate the 6 common wires from the high voltages cables. Separate the 6 common wires from the two 4Vac wires or cable them together only for a short distance. Check the ID (..4) of the door station to be recalled and press the camera recall button as many time as the ID value. Check the address of the videophone you are calling and try again. Check that the wires are not broken or shorted. Set both switches to the position. Use x 75 Ohm resistors to connect V & V to 0V. Wrong connection or call button broken. Check connection or replace the button EN - V 3.4-3/08/6
7 Art Speaker unit When installing you see the back side of the door panel Colour B&W Aluminium Stainless steel Fig. Fig. CTROLS (SPEAKER & MICROPHE VOLUME) Trimmer to adjust the speaker volume. Rotate clockwise to increase or anti- clockwise to decrease. Trimmer to adjust the microphone volume. Rotate clockwise to increase or anticlockwise to decrease. SETTINGS (DIP-SWITCH & JUMPERS) 4 WAY DIP-SWITCH First two switches are used to set the speaker unit address: the speaker unit address is required for camera recall operation on or more entrance systems. SW Switches, Unit Address OFF OFF OFF OFF 3 4 SW Switch 3 Conversation Time OFF 60 seconds 0 seconds SW Switch 4 Door opening time (J = L position) OFF seconds 6 seconds EN - V 3.4-3/08/6
8 Art Speaker unit JUMPERS J, J, J3 J= J= J= J= J3= Reassurance tone volume = High Reassurance tone volume = Low Door open relay operating mode = Capacitor discharge Door open relay operating mode = Dry Contacts Only for Art , call buttons operating mode = each button calls a different videophone Only for Art , call buttons operating mode = both buttons call the same videophone J3= When the door open relay operating mode is set to capacitor discharge *, one terminal of the electric lock must be connected to ground while the second must be connected to NO terminal. The NO terminal will supply a temporary voltage when the speaker unit receives the door open command. * When capacitor discharge operating mode is set, one terminal of the electric lock must be connected to the ground while the second one must be connected to NO terminal. The NO terminal will supply a temporary voltage when the speaker unit receives the door open command (we suggest to use a Vac/dc A max electric lock). Setting dry contacts operating mode, when the speaker unit receives the door open command, the NO terminal will be internally linked to the C terminal for the programmed time (switch 4 of the 4 way dip-switch bank). SIGNALS (TERMINALS) NO Door open relay normally open contact NC Door open relay normally closed contact Max 4Vdc, 3mA when used as dry contacts relay C Door open relay common contact PTE Active low input to control directly the door open relay SL Active low output to enable the enslavement relay for video signal exchange (active with a call in progress) BS Input/Output busy signal (about V in stand-by, about 0V with a call in progress) V Balanced video signal sync.+ V Balanced video signal sync. Speech line output from the microphone (about V in stand-by, about 3V with a conversation in progress) Speech line input toward the loudspeaker and data signal (about V in stand-by, about 5V with a conversation in progress) Vout Vdc. 0,3A max. output to supply accessiories Power input ground +V Power input 6 0Vdc TECHNICAL SPECIFICATI Power Supply: 0Vdc Power consumption: Stand-by: 70mA Operating: 50mA Working Temperature: C EN - V 3.4-3/08/6
9 Art Art Digital codelock module DESCRIPTI Access control system with codes and Relay outputs for Art (3 codes and 3 Relay outputs for Art ). Engineer s code to enter into the Programming Menu ( from 4 to 8 digits). Programming of the activation time of each relay from up to 99 seconds or latching. Possibility to activate relay by shorting terminal SW to GND and relay by shorting terminal SW to GND. Both relays will operate for the programmed time. Keypad gives an acoustic (buzzer) signal during the entering of codes and a continuous melody for 4 or more seconds, according to the number of mistakes (self protection). Keypad includes panel illumination and LED s to show the following:»» Correct relay code (green LED on for seconds).»» Red LED to indicate when in the programming menu. MODELS Art. 8800: Module Relay with keypad illumination LEDs Art : Module 3 Relay with keypad illumination LEDs Fig. OPERATI To use the system, type in the programmed code and press ENTER, the green LED will illuminate and the relay will operate for the programmed time.to cancel remain open time, type in the same code and press CLEAR. If a wrong code is entered, a continuous melody will sound for 4 or more seconds, according to the number of mistakes. INITIALIZATI When the installation is concluded and carried out according to the wiring diagram, power up the system and program it by following the VX8800 PROGRAMMING Flow Chart. PROGRAMMING Refer also to flow chart. Enter ENGINEER S CODE : first time type six times ( factory preset) and press ENTER (The red LED will illuminate). Confirm ENGINEER S CODE (typing again the same) or type the new code (4 to 8 digits) then press ENTER (Melody). Pressing twice the ENTER button without changing the ENGI- NEER S CODE, will exit from the programming. Enter the code (4 to 8 digits) to enable RELAY (ACCESS ) or re-enter the existing code then press ENTER (Melody). Enter the RELAY operation time ( digits 0 to 99 I.E. 05=5 seconds, 00= remain open time) or re-enter the existing time then press ENTER (Melody). Enter the code (4 to 8 digits) to enable RELAY (ACCESS ) or re-enter theexisting code then press ENTER (Melody). Enter the RELAY operation time ( digits 0 to 99 I.E. 05=5 seconds, 00=remain open time) or re-enter the existing time then press ENTER (Melody). Enter the code (4 to 8 digits) to enable RELAY 3 (ACCESS 3 only for Art ) or re-enter the existing code then press ENTER (Melody). Enter the RELAY 3 (only for Art ) operation time ( digits 0 to 99 I.E. 05=5 seconds, 00=remain open time) or re-enter the existing time then press ENTER (Melody). The system is ready to use (the red LED will be off). Press Enter (Red LED will be ) Press Enter (melody) Press Enter (melody) Press Enter (melody) Press Enter (melody) Press Enter (melody) Press Enter (melody) Press Enter (melody) *** Only for Art ENTER THE "ENGINEER S CODE" CFIRM OR CHANGE "ENGINEER S CODE" ENTER "ACCESS CODE" ENTER "ACCESS TIME" ENTER "ACCESS CODE" ENTER "ACCESS TIME" ENTER "ACCESS 3 CODE"*** ENTER "ACCESS 3 TIME"*** SYSTEM READY TO USE First time six times factory preset Type again six times or the new engineer s code 4 to 8 digits Code to enable relay 4 to 8 digits Two digits (0 to 99) i.e. 05=5 Seconds 00= remain open Code to enable relay 4 to 8 digits Two digits (0 to 99) i.e. 05=5 Seconds Code to enable relay 3 4 to 8 digits Two digits (0 to 99) i.e. 05=5 Seconds Red led will be off EN - V 3.4-3/08/6
10 Art Art Digital codelock module INSTRUCTI TO RETURN SYSTEM TO PRESET ENGINEER S FACTORY CODE Turn off power to code lock. Keep ENTER button pressed while turning back on the power to the code lock. Release ENTER button. The master code is now set at factory engineer s code (six times ). Proceed with programming for a new system. NOTES To switch off any relay while operating, type in the relevant code then press the CLEAR button. To operate relays together, set the same code for each relay. If a wrong code is entered, the system will lock out for 5 seconds which will increase each time a wrong code is entered. The system will operate only when the correct code is entered. GENERAL DIRECTIS FOR INSTALLATI In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly keeping to the items indicated on each schematic and follow these General Directions for Installation: The system must be installed according to national rules in force, in any case the running of cables of any intercom unit must be carried out separately from the mains; All multipair cables should be compliant to CW308 specification (0.5mm twisted pair telephone cable.»» Cables for speech line and service should have a max resistance of 0Ω»» Lock release wires should be doubled up (Lock release wires and power supply wires should have a max resistance of 3Ω); The cable sizes above can be used for distances up to 50m. On distances above 50m the cable sizes should be increased to keep the overall resistance of the cable below the RESISTANCES indicated above; Double check the connections before power up; Power up the system then check all functions. LOCK RELEASE BACK EMF PROTECTI A varistor must be fitted across the terminals on AC lock release (Fig.A) and a diode must be fitted across the terminals on a DC lock release (Fig.B) to suppress back EMF voltages. Connect the components to the lock releases as shown in figures. VARISTOR (MOV) DIODE N400 V AC LOCK RELEASE V DC LOCK RELEASE Fig. A Fig. B EN - V 3.4-3/08/6
11 Art Art Digital codelock module RE-PROGRMMING GUIDE Press Enter (Red light will illuminate*) Press Enter Press Enter Press Enter YES Repeat steps for relay and relay 3*** ENTER THE ENGINEER S CODE RE-ENTER THE ENGINEER S CODE ENTER ACCESS CODE ENTER ACCESS TIME MORE DOORS? NO PRESS ENTER TWICE TO EXIT PROGRAMMING Alternatively enter a new engineer s code (4 to 8 digits) Relay code (4-8 digits) operate the door or gate.** Two digits (0-99 sec or 00 for remain open) Engineer s code Relay code Relay code Relay 3 code*** Relay time Relay time Relay 3 time*** Notes: * If the red light does not illuminate, the engineer s code is incorrect. Follow instructions to return system to preset engineer s factory code. ** On the first loop of the flow chart its relay, second loop is relay and third loop is relay 3. *** Only for Art ART TERMINALS SW Relay command signal (active low) SW Relay command signal (active low) NC Relay normally closed contact NO Relay normally open contact C Relay common contact NC Relay normally closed contact NO Relay normally open contact C Relay common contact Max 4Vac/dc ART TERMINALS NO3 Relay 3 normally open contact C3 Relay 3 common contact NC Relay normally closed contact NO Relay normally open contact C Relay common contact NC Relay normally closed contact NO Relay normally open contact C Relay common contact Max 4Vac/dc /+ /4Vac/dc power input / /+ /4Vac/dc power input / TECHNICAL SPECIFICATIS Power requirements: /4V AC/DC, VA Power Consumption: On AC On DC Stand-by: 8mA Stand-by:.5mA Operating: 5mA Operating: 35.0mA Working Temperature: C EN - V 3.4-3/08/6
12 8000 Series Surface and flush mounting door station installation INSTALLING A FLUSH MOUNTING DOOR STATI. Mount back box S (Fig. ) at 65 cm from ground level (Fig. );. If more than one flush box is needed, connect them by using the plastic spacers provided A (Fig. ); 3. If necessary finish and clean properly the module support fixing holes and all other holes B (Fig. ); 4. A rainshield D (Fig. 3 & 4) can be mounted using the fixing screws G (Fig. 4) to conceal possible wall finishing defects and protect against rain; In order to prevent water ingress we highly recommend using a silicon sealant between the wall and the back box and between the wall and the rainshield D (Fig.3); 5. Remove the fixing screws H (Fig. 5) and remove the plastic cover E (Fig. 5) of the module support; 6. Insert the modules F (Fig. 6) according the required configuration; 7. Insert the microphone of the door unit amplifier into the microphone hole X (Fig. 7); 8. Secure the modules by refitting the plastic cover E (Fig. 8) and using the screws H (Fig. 8); 9. Insert the hinge I (Fig. 9) and fix it with the two screws K (Fig. 9) provided; 0. Make all connections following accurately the wiring diagram provided. Check the installation and if necessary adjust speech levels using volume controls L (Fig. 9);. Lever the support R (Fig. 0) upwards and fix it to the back box with the screw M (Fig. ) using an alan key P (Fig. );. Conceal the screw using the plastic cover N (Fig. ) provided. INSTALLING A SURFACE MOUNTING DOOR STATI Fix the surface box on the wall at a distance of 65 cm between the top of the box and the ground (Fig. ). In order to prevent water ingress we highly recommend using a silicon sealant between the wall and the back box J (Fig.) and around all holes W (Fig.). To complete the installation follow the same steps described above for the flush box. Note: if additional holes are made in the box or rainshield, oxidation problems may appear unless the unprotected metal is coated with a protective paint. HOW TO REMOVE THE CARD NAME HOLDER To avoid damage to the module front plate, tape the side that will be in contact with the screwdriver blade; lnsert a flat screwdriver into the card-holder hole as shown in Fig. 3; Move the screwdriver to the left as shown in Fig. 4 to extract the card name holder; Edit the card name then replace it inside the holder and refit: insert the holder inside its housing from the left or right side then push the other side until it clips into place EN - V 3.4-3/08/6
13 8000 Series surface and flush mounting door station installation EXAMPLE: INSTALLING A TWO MODULE OUTDOOR STATI A S B B Fig. Fig. Fig. 3 D S F D E G Fig. 4 Fig. 5 H Fig. 6 X E I K L Fig. 7 Fig. 8 H Fig. 9 M J P N R W Fig. 0 Fig. Fig. Fig. 3 3 Fig EN - V 3.4-3/08/6
14 Art " hands free colour display digital videophone 7 mm 0 mm +V V V LB SB LD A 3A 4A M 8 mm DSW DSW PT PT3 PT SW VR Fig. Fig. DESCRIPTI Surface mount hands free videophone incorporating a 3.5 Hi-Res full colour active matrix LCD monitor designed specifically for the 6 wire videokit (VK4K, VRVK and VK8K range). Including 4 buttons: camera recall open door service and privacy. LED s* to indicate the privacy activated and open door. Programmable privacy duration and number of rings. Intercommunicating call and door call. Adjustments: call tone volume switch (3 levels), picture hue, contrast and brightness. * The operation of some LED s and the functions described may require additional cabling PUSH BUTTS (FIG. ) Service push button. Shorts the SB terminal to GROUND (open collector 4Vdc 00mA max) while the button remains pressed. Privacy -OFF button. When the system is in stand-by, the pressing of this button activates (LED switched on) or disables (LED switched off) the privacy service. The service is automatically disabled when the programmed privacy time expires. When the service is enabled the videophone does not receive calls. Door-open / intercommunicating call button. With the speech lines open to the entrance panel, press this button to open the door. If the terminal LD is properly connected the relevant LED remains switched until the door is closed. Intercommunication only works when the system is in the stand-by condition. Switch 4 of the SW dip-switch selects the type of intercommunication: OFF Intercommunication between two apartments - press the key button to call the videophone(s) in the other apartment. A busy tone will signal that the other videophone is in conversation with the door station and so cannot be called. Intercommunication between videophones in the same apartment - press the key button one, two, three or four times to call videophone with extension address,, 3 or 4 (Set on dip-switches &3 of SW). Any intercommunicating conversation is always interrupted by an external call (i.e. External calls take priority). Intercommunication push button. For an intercommunicating call, press as many times as the extension or address value to call (see SW3 Intercommunication Settings) EN - V 3.4-3/08/6
15 Art " hands free colour display digital videophone PUSH BUTTS (FIG. ) Answer push button. On an incoming call, pressing this button allows the user to answer and converse with the visitor. The relevant LED will illuminate. Switch off button. With the system switched on (monitor on), momentary operation of the button will switch the video monitor off. The videomonitor will also automatically switch off after a time delay if the button is not pressed. The relevant LED will switch off. Camera recall button. Press the button (Press once for door/gate, twice for and so on up to a maximum of 4 entrances): the relevant LED switches and the monitor switches on showing the video from the door panel. The speech is also live and the door can be opened by pressing. Simplex button. Pressing and holding the button for more than 3 seconds will switch the videomonitor into SIMPLEX speech mode. Press and hold the button to speak to the caller ( LED will flash rapidly), release the button to listen ( LED will flash slowly). If the button is not pressed for 0 seconds the videomonitor will switch off. The videomonitor will revert to duplex speech when another call is made. LEDS (FIG. ) Privacy on LED. LED It illuminates when the privacy service is enabled. Generic use LED. It is controlled from the terminals +DOL and LED -DOL. Normally used to signal the door status (open or closed). LED. LED It illuminates when the videophone is switched. CTROLS AND ADJUSTMENTS (FIG. AND FIG. ) PT PT3 PT SW VR Brightness control (sliding wheel). Speech volume control (3 levels). Call tone volume control (sliding wheel). Colour intensity control trimmer (rotate left to increase or right to decrease). Contrast control trimmer (rotate left to increase or right to decrease). SETTINGS (DIP-SWITCH) The videophone setup is carried out by the dip-switch banks. Switch Apartment Address OFF Switches,3 Extension Address OFF OFF OFF OFF 3 4 Switch 4 Intercommunication OFF Between videophones in another apartment Between videophones in the same apartment Switches 5,6 Number of rings OFF OFF OFF 4 OFF 6 8 Switches 7,8 Privacy duration time OFF OFF 5 minutes OFF hours OFF 4 hours 8 hours EN - V 3.4-3/08/6
16 Art " hands free colour display digital videophone WAY DIP-SWITCH (SW) The two way dip-switch adjusts the impedance of the video signal. The default setting is for both switches (75 Ohm): when there are more videophones in parallel connection (without video distributor) both switches must be only on the last videophone (looking at the connection order) while for all other videophones both switches must be set to OFF. SIGNALS CNECTI BOARD +V 0Vdc Input/Output (As input 6 0Vdc 0, as output 0Vdc 0, max) Ground reference for +V terminal. Speech line output from microphone and data signal (Approx. V in stand-by, 5V during a conversation) Speech line input toward the loudspeaker (Approx. V in stand- by, approx. 3V during a conversation) V Balanced video signal sync. V Balanced video signal sync.+ 4Vac A max power input LB SB LD A 3A 4A M Local call input (5V in standby, 0V to trigger) Service button (open collector) active low output. The button goes active when the button is pressed (Open Collector 4Vdc 00mA max) Vdc input for door-open LED Speech line input toward the loudspeaker of the parallel telephone (Approx. V in stand-by, 3V during a conversation) Output switched ground for parallel telephone Output call tone for parallel telephone Input for door-open command from parallel telephone Vdc power supply for Memory Board version TECHNICAL SPECIFICATI Power Supply: 4Vac in or 0Vdc in Power consumption: Stand-by: 50mA Max Operating: 50mA Max Working Temperature: C EN - V 3.4-3/08/6
17 6300 Series Wall mounting instructions C D B A E F 35cm B A C F Fig. Fig. Fig. 3 Fig. 4 Fig. 5 Fig. 6. In order to install the videophone, it is necessary to remove the cover, which contains all the electronics, from the base: press lightly on the bottom part of the videophone and simultaneously pulling outwards the upper part as shown in Fig... Put the base of the unit on the wall at approx 35cm from the finished floor to match the points for the fixing holes A (Fig. ) remembering that the wires D (Fig. 3) must be fed through the large hole E (Fig. 3). If you use the flush mounting box 503, embed it into the wall vertically at approx. 40cm from the finished floor and the base. 3. Following Fig. 3, make the holes A, insert the wall plugs B and fix the base with the screws C feeding the wires D through the hole E. If you have used the box 503, fix the base to the wall through the holes F using the screws C. 4. As shown in Fig. 4, connect the wires to the removable terminals following the provided installation diagram. Connect the terminal blocks to the electronics contained in the cover as shown in Fig. 5. Test system before closing. Contrast and hue trimmers can be adjusted only if the videophone is open. To activate the display and see changes use the Camera Recall function by pressing button. Note: while testing the system, it is advisable to hold the cover with your hand. 5. Once testing is complete and all the necessary adjustments are made, close the unit as shown in Fig. 6: first hook in the bottom and the then the top until you hear a click EN - V 3.4-3/08/6
18 Installation diagrams NOTES AND SUGGESTIS All diagrams refer to all kits versions: flush or surface, colour or black & white. Dashed connections refer to optional connections ( Local bell, Push to exit & Door monitor ). Some diagrams show how to connect a Vdc electric lock: these directions are suitable for all diagrams in this manual. Each time a setting is changed on a videophone (address, extension, number of rings etc.), the videophone must be disconnected from the relevant connection board then after a few seconds reconnected again to allow the recognizing of the new setting. All diagrams shown are valid for B&W or colour systems with surface or flush mount door station. DECLETI OF RESPSIBILITY This manual has been written and revised carefully. The instructions and the descriptions which are included in it are referred to VIDEX parts and are correct at the time of print. However, subsequent VIDEX parts and manuals, can be subject to changes without notice. VIDEX Electronics S.p.A. cannot be held responsible for damages caused directly or indirectly by errors, omissions or discrepancies between the VIDEX parts and the Manual. WE RECOMMEND This equipment is installed by a Competent Electrician, Security on Communications Engineer EN - V 3.4-3/08/6
19 Installation diagrams VIDEOKIT VK8K-/6358, VK8K-S/6358 Local Bell +V V _ SW SW V LB Art.6358 Address N. Ext. SB LD A 3A 4A M In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect Door Monitor Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Push to Exit Art Art Title: Titolo: Videx Electronics S.p.A. Notes: Via del Lavoro, 6300 Monte Giberto (AP) Phone: Fax Note: - info@videx.it Data creazione: Foglio 0//05 Data modifica: 0//05 Autore: Marco Rongoni Cod.File: / vk8k63h-00.dwg EN - V 3.4-3/08/6
20 Installation diagrams VIDEOKIT VK8K-/6358, VK8K-S/6358 Local Bell Local Bell In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Art Push to Exit Art V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. +V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. 0 0//05 0//05 Marco Rongoni vk8k63h-003.dwg EN - V 3.4-3/08/6
21 Installation diagrams VIDEOKIT VK8KC-/6358, VK8KC-S/6358 Local Bell +V V _ SW SW V LB Art.6358 Address N. Ext. SB LD A 3A 4A M Door Monitor In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect + Art.8800 Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Push to Exit Art Art Title: Titolo: Videx Electronics S.p.A. Notes: Via del Lavoro, Monte Giberto (FM) Phone: Fax Note: - info@videx.it Data creazione: Foglio 0//05 Data modifica: 0//05 Autore: Marco Rongoni Cod.File: / vk8k63h-004.dwg EN - V 3.4-3/08/6
22 Installation diagrams VIDEOKIT VK8KC-/6358, VK8KC-S/6358 Local Bell Local Bell In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect + Art.8800 Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Push to Exit Art Art V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. +V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. 0//05 0//05 Marco Rongoni vk8k63h-005.dwg EN - V 3.4-3/08/6
23 Installation diagrams VIDEOKIT VK8K-/6358, VK8K-S/6358 WITH ADDITIAL INTERCOM AND EXTENSI SOUNDER +V V _ SW SW V LB Art.6358 Address N. Ext. SB LD A 3A 4A Local Bell M Affinche qualsiasi modifica alle impostazioni dei dip switch del videocitofono o del posto esterno venga riconosciuta dal sistema, è necessario togliere l'alimentazione di rete all'impianto e restituirla. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting temporarily disconnect the system from the mains and reconnect YELLOW VOL.REG. BLACK RED 4 GREEN Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Push to Exit Art Art Title: Titolo: Videx Electronics S.p.A. Notes: Via del Lavoro, Monte Giberto (FM) Phone: Fax Note: - info@videx.it Data creazione: Foglio 0//05 Data modifica: 0//05 Autore: Marco Rongoni Cod.File: / vk8k63h-006.dwg EN - V 3.4-3/08/6
24 Installation diagrams VIDEOKIT VK8K-/6358, VK8K-S/6358 WITH ADDITIAL DOOR PANEL FOR ENTRANCES SYSTEM Local Bell In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. +V V _ SW SW V LB Art.6358 Address N. Ext. SB LD A 3A 4A M In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect 5 NO Push to Exit 4 3 Art.506N NC CO NO NC C0 Push to Exit Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Art ID: Art Art ID: Title: Titolo: Videx Electronics S.p.A. Notes: Via del Lavoro, Monte Giberto (FM) Phone: Fax Note: - info@videx.it Data creazione: Foglio 0//05 Data modifica: 0//05 Autore: Marco Rongoni Cod.File: / vk8k63h-007.dwg EN - V 3.4-3/08/6
25 Installation diagrams VIDEOKIT VK8KC-/6358, VK8KC-S/6358 WITH 3 ADDITIAL VIDEOPHES Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Art In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect Push to Exit + Art.8800 Art V _ SW SW V V LB SB LD A 3A 4A M +V _ SW SW V V 4A LB SB LD A 3A M +V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. Art.6358 Address N. Ext. Art.6358 Address N. Ext //05 0//05 Marco Rongoni vk8k63h-008.dwg EN - V 3.4-3/08/6
26 Installation diagrams VIDEOKIT VK8K-/ VK8K-S/6358 WITH ART. 36 Local Bell Local Bell In caso di modifica alle impostazioni dei dip switch del videocitofono o del posto esterno, togliere temporaneamente l'alimentazione di rete. In order to make the system recognize any modification of the videophone's and outdoor station's dip-switch setting, temporarily disconnect the system from the mains and reconnect Using Electric Lock Vdc 0.3A Max Con serratura elettrica Vdc 0.3A Max Art Push to Exit Art V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. +V _ SW SW V V LB SB LD A 3A 4A M Art.6358 Address N. Ext. 6 0//05 0//05 Marco Rongoni vk8k63h-00.dwg EN - V 3.4-3/08/6
27 Installation diagrams TWO ENTRANCES SYSTEM INSTALLATI V V GND +0V Art.506N NO NC CO NO NC C0 30V + - 8Vdc ART. 33/8 Push to Exit Push to Exit Art Art ID: Title: Titolo: Videx Electronics S.p.A. Notes: Via del Lavoro, Monte Giberto (FM) Phone: Fax Note: - info@videx.it 7 ID: Data creazione: 8/0/05 Data modifica: 8/0/05 Autore: Cod.File: Foglio Marco Rongoni / vk8k--00-e.dwg EN - V 3.4-3/08/6
28 MANUFACTURER VIDEX ELECTRICS S.P.A. Via del Lavoro, Monte Giberto (FM) Italy Tel (+39) Fax (+39) info@videx.it CUSTOMER SUPPORT All Countries: VIDEX ELECTRICS S.P.A. - technical@videx.it Tel: Fax: UK Customers: VIDEX SECURITY LTD Tech Line: Fax: Main UK office: VIDEX SECURITY LTD Osprey Trinity Park Trinity Way LD E4 8TD Phone: (+44) Fax: (+44) marketing@videx-security.com Northern UK office: VIDEX SECURITY LTD Unit 4-7 Chillingham Industrial Estate Chapman Street NEWCASTLE UP TYNE - NE6 XX Tech Line: (+44) Phone: (+44) Fax: (+44) Greece office: VIDEX HELLAS Electronics 48 Filolaou Str. 633 ATHENS Phone: (+30) (+30) Fax: (+30) videx@videx.gr Danish office: VIDEX DANMARK Hammershusgade 5 DK-00 COPENHAGEN Phone: (+45) Fax: (+45) videx@videx.dk Benelux office: NESTOR COMPANY NV E3 laan, 93 B-9800 Deinze Phone: (+3) Fax: (+3) info@videx.be Dutch office: NESTOR COMPANY BV Business Center Twente (BCT) Grotestraat, 64 NL-76 GM Borne info@videxintercom.nl The product is CE marked demonstrating its conformity and is for distribution within all member states of the EU with no restrictions. This product follows the provisions of the European Directives 04/30/EU (EMC); 04/35/EU (LVD); 0/65/EU (RoHS): CE marking 93/68/EEC.
VIDEOKIT VK8K/6256 SERIES 6 Wire bus one way, two way videokit VK8K VK8KC. Installation handbook. English
English VIDEOKIT VK8K/656 SERIES 6 Wire bus one way, two way videokit VK8K VK8KC 656 Installation handbook 6650865-EN V 3.4 3/08/6 We recommend This equipment is installed by a Competent Electrician, Security
More informationVIDEOKIT VK4K/3656 SERIES 6 Wire bus one way, two way videokit VK4K VK4KC. Installation handbook. English
English VIDEOKIT VK4K/3656 SERIES 6 Wire bus one way, two way videokit VK4K VK4KC 3656 Installation handbook 6650454-EN V 3.4. 5/09/6 We recommend This equipment is installed by a Competent Electrician,
More informationArt. 4KC/ G Audiokit with digital codelock
Art. 4KC/3011-3012-3111-3112-3102G Audiokit with digital codelock GENERAL DIRECTIONS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only
More informationArt. 8K-1/2-8K-1S/2S Audiokit
Art. 8K-1/2-8K-1S/2S Audiokit GENERAL DIRECTIONS FOR INSTALLATION In order to achieve the best results from the schematics described it is necessary to install only original VIDEX equipment, strictly keeping
More informationVIDEOKIT IPVK/6296 SERIES IPVKC/6296 SERIES IP one way, two way videokit
VIDEOKIT IPVK/6296 SERIES IPVKC/6296 SERIES IP one way, two way videokit Installation handbook We recommend This equipment is installed by a Competent Electrician, Security or Communications Engineer.
More informationArt. 316C VX RJ-45 A/V distribution box
ccessories rt. VX00 RJ /V distribution box ENG Fig. DESRIPTI Due to the popularity of T cable for use on video intercom system Videx have developed the rt., a way distribution box with RJ connections for
More informationArt. 4212V-4212RV Audio/video digital front panel
Art. 4212V-4212RV Audio/video digital front panel Wide angle colour camera Speaker Display Keyboard Art. 4212V Art. 4212RV Fig. 1 Front view Voice annunciation speech adjustment 12T GNDV V2/V V1 PTE TRD
More informationTECHNICAL MANUAL. 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1
TECHNICAL MANUAL 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1 INTRODUCTION The door entry kit has the following features: Electronic call tone - Upon a call being initiated, the
More informationTECHNICAL MANUAL EDITION 1.4 SENTRY TECHNICAL MANUAL
TECHNICAL MANUAL EDITION 1.4 SENTRY TECHNICAL MANUAL CONTENTS PAGE Manual Introduction 2 System Introduction 2 System Components 2 12 System Operation 13 Vandal Resistant Panel layout and sizes 14 Installation
More information2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM
2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM CONTENTS PAGE Manual Introduction 3 Product Overview 3 Operation and Connection 3 RS232 Connection 3-4 RS485 Connection 3-4 2214 PCB layout 5 RS485 Bus Terminal
More informationVIDEX have been UNI ISO 9001 certified since 2005.
GSM 2017 Founded in 1986, Videx designs and manufactures video/audio door entry systems and access control, standing among the leading companies in the field worldwide. The extensive range, quality, service,
More informationTECHNICAL MANUAL EDITION 1.6 VX2200 DIGITAL SYSTEM
TECHNICAL MANUAL EDITI 1.6 VX00 DIGITAL SYSTEM PAGE of 68 VX00 TECHNICAL MANUAL CTENTS PAGE Manual introduction 4 System introduction 4 Digital door panels 5-9 Digital door panel programming flow chart
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationPS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0
PS 230 DUAL CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...
More informationPS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0
PS 430 FOUR CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...
More informationProduct Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)
Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:
More informationPUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a
SECTION 3A (Rev. B) Download from www.urmet.com Technical Manuals area. SINTHESI 2 CAMERA MODULE AND DOOR UNIT WITH 2 BUTTONS...2 Features...2 Structure...2 Terminals pins description...3 Technical characteristics...3
More information8000 series Modular System
As a direct result of the overwhelming success of the 4000 Series, Videx have remodelled and improved the popular 800 Series and introduced, as its replacement the Videx 8000 Series. The Videx 8000 range
More information25H/SP/DDA/2W. Technical Manual VIDEX CALL. (1 Way 2 Wire DDA Audio Intercom Kit)
25H/SP/DDA/2W (1 Way 2 Wire DDA Audio Intercom Kit) SPEAK BUSY OPEN CALL Technical Manual 25H/SP/DDA/2W EN-UK V.1.2 04/01/16 WE RECOMMEND This equipment is installed by a Competent Electrician, Security
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationAudio & Video Kit Catalogue 2015/2016
Audio & Video Kit Catalogue 2015/2016 Audio & Video Kits Index Audio & Video Kit Catalogue 2015/2016 Audio range 8000 SERIES 8K Audiokit Digiphone Kit Interkit 4000 SERIES Audiokit Digiphone Kit Vproxphone
More informationVR GSM AUDIO INTERCOM KIT 4000 Series Vandal Resistant GSM Audio Intercom with Proximity Facility
ENG VR GSM AUDIO INTERCOM KIT 4000 Series Vandal Resistant GSM Audio Intercom with Proximity Facility GSMVRK GSMVRKC Technical Manual 66250675-EN V1.1-20/02/18 We recommend This equipment is installed
More informationGSM AUDIO INTERCOM KIT
ENG GSM AUDIO INTERCOM KIT 4000 Series GSM Audio Intercom with Proximity GSM4K GSM4KC Technical Manual 66250753-EN V1.6-20/02/18 We recommend This equipment is installed by a Competent Electrician, Security
More informationPS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016
PS 150 SINGLE CHANNEL TELEPHONE INTERFACE USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:
More informationFront-door station series for surface-mounting Profi-Economic PES Profi-Design PDS
Product information Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS PI_GB_PES_PDS_Art0015689_1v0.doc 2 10/2005 In Table of contents Scope of delivery...3 Safety notices...3
More informationInstallation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation
-V/AB & ABK V.5 (2 ) Important Notes: ) Before you install this equipment, please read this full manual. Installation Manual Wiring 8) Carefully follow the wiring instructions. 2) Before fully installing
More informationduplex communication (with handset) hands-free talking simplex communication can be activated standard 4 (up to 2 from front-door stations)
Page 1/6 home:packs for the one- and two-family house with comfort functions Types of packages PSC2110-0000 for the one-family house, duplex communication 1 x ISH3130-0140 1 x PAK (surface-mount) 1 x power
More informationMain menu. Camera/Door. Intercom. Playback. Do not disturb USER MANUAL VESTA2 GB2 MONITOR
Camera/Door Playback USER MANUAL VESTA2 GB2 MITOR https://alphacommunications.com AWD211 Rev 07/2018 VESTA2 GB2 MITOR 2 INTRODUCTI First and foremost we would like to thank you for purchasing this product.
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More informationDP2 DOOR PHONE. For Technical Assistance Please Phone: (07)
DP2 DOOR PHONE For Technical Assistance Please Phone: (07) 5596 5128 TABLE OF CONTENTS Description Page 3 Door Phone Dimensions Page 4 Door Phone Range Page 5 Door Phone Performance Page 6 Operation Summary
More informationPS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0
PS 630 SIX CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 REAR PANEL CONNECTORS...
More information1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815
95-10324_V2016-11-23 IF-812/IF-815 1 IF-812 or IF-815 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-812 or IF-815 terminal (slave), you have purchased a reliable device for capturing
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More information1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811
95-10326_V2016-10-20 IF-810/IF-811 1 IF-810 or IF-811 Terminal (Slave) Thank you for choosing an Interflex system. With an IF-810 or IF-811 terminal (slave), you have purchased a reliable device for capturing
More informationVideo kit with 1 hands-free internal unit, surface-mounting. Video kit with 2 hands-free internal units, surface-mounting
Access control 7 7.01-1 Access control Kits Video kit with 1 hands-free internal unit, surface-mounting This video kit contains: one surface-mounting compact aluminium external video unit with one bell
More informationZartek. CDP-808 Two Button Wireless Intercom Installers Manual
Zartek CDP-808 Two Button Wireless Intercom Installers Manual ZA-614 Two Button Gate station including power supply, relay board and external antenna ZA-613 Handsets with charger ZA-613-E Handsets with
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationAGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK
TARGHA 200 A/200N AGATA C200 UK Installation Manual AGATAKIT C 200 UK 24806770/28-05-2013 AGK200C03UK HPC/1 AGATA C200 UK AG2K200C03UK HPC/2 HA/200 HBP AG3K200C03UK HPC/3 A/200N AGK200C03HNA HPC/1+HNA
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationINSTALLATION INSTRUCTIONS Model 930 EntryCheck
SECURITY DOOR CONTROLS 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 Fax: (805) 494-8861 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS Model 930 EntryCheck
More informationSection A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment
April 2015 PRICE SCHEDULE A 2.0 Section A5 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. Prices and specifications subject to change without
More informationACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features
Audio Door Entry with Access Control ACTentry A5 Kit Audio Door Entry & Access Control Kit Each kit comprises a door entry panel intercom power supply unit ACTEntryA5ICOM-K ACTentry A5 Entry Panel Audio
More informationTrademark Generation II Series Intercom System Installation and Operation Reference Guide
Trademark Generation II Series Intercom System Installation and Operation Reference Guide www.escoservices.com Components: Desktop Controller, Digital Interface Box, -Speaker I/O Card, 9VDC Power Supply
More information8-wire Digital. Audio/Video Intercom Systems. Catalogue
8-wire Digital Audio/Video Intercom Systems Catalogue Quality Certification BTicino has always been aware of and attentive to the highest standards for production and management systems. BTicino has formalised
More informationINTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual
INTERQUARTZ Doorphone ID 201 Doorphone ID 202 Doorphone ID 204 User manual Contents 1 BASIC DESCRIPTION... 3 1.1 FEATURES... 3 1.2 SLIMDOORPHONE MODELS... 4 2 INSTALLATION... 4 2.1 OPENING, WIRING, WALL
More informationWALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2
SECTION G (Rev.E) 8 WALL MOUNTED PANEL 8 Download from www.urmet.com Technical Manuals area. SMYLE WALL-MOUNTED PANEL SECTION CONTENTS SPECIAL MODULES...8 TECHNICAL FEATURES... DOOR UNITS... Door phone
More informationTELEPHONE TECHNICAL SERVICES DS2 USER GUIDE
TELEPHONE TECHNICAL SERVICES DS2 USER GUIDE Manufactured in Australia for Telephone Technical Services PO BOX 675 SPRINGWOOD QLD 4127 TABLE OF CONTENTS Description Pages 3-4 Door Phone Options Page 5 Door
More informationOperating manual MVC-6650
1. Safety of use - Monitor connection should be made by a specially trained fitter. - Monitor should be connected to the system with power supply cut off. Power supply should be switched on after making
More informationV-9941A ONE ZONE HANDSFREE TALKBACK CONTROL UNIT
VSP- Issue 4 ONE ZONE HANDSFREE TALKBACK CONTROL UNIT INTRODUCTION The is a One Zone Handsfree Page Unit for use on an Electronic Key system line key position, a PABX loop start trunk port, a dedicated
More informationIndoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range
Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting
More informationMULTIWAY 2-12 WAY DOOR ENTRY SYSTEM
MULTIWAY 2-2 WAY DOOR ENTRY SYSTEM FTDEVM2-2 Instruction Rev0 CONTENTS Part. Product introduction. Panel(s) layout.2 Specification Part 2. Connection 2. Cable requirements 2.2 Cables and distance 2.3 Terminals
More informationJanuary 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control
January 2013 PRICE SCHEDULE A 2.0 Section A4 Date Page Comment 1 1 13 All January, 2013 Price Schedule update. 2 13 13 6 Removed 1812 092 from 1812 145 kit. Added 1812 092 to 1812 147 kit. 2 13 13 9 P/N
More information} Power ground. Mod ATLANTICO DOOR PHONES. ATLANTICO DOOR PHONES Mod Mod ATLANTICO DOOR PHONES TECHNICAL SPECIFICATIONS
Electronic call Atlantico door phones model 33 are suitable for use in 4+n and + system types. Characteristics of Atlantico door phones are: Innovative, simple, essential design by Michele De Lucchi. Telephone-like
More information5000 Series Audio Matrix
5000 Series Audio Matrix FOR TECHNICAL SUPPORT CALL 513-795-5332 For more complete system information see the document 5000 Series Audio/Video System Installation & Service Manual 08-316 (11/12/13) Matrix
More informationRemote units Hands free or telephone handset options available. Master to remote and remote to master calling
(ORB/L/RS16 LOOP WIRED) Remote units Hands free or telephone handset options available Master to remote and remote to master calling Fully monitored for open and short circuit cable failures. Remotes connected
More informationThe Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.
Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel
More informationAUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL
AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen
More informationApril 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control
Section A6 This Price Schedule is effective April 1, 2015. Date Page Comment 4-1-15 All April, 2015 Price Schedule update. 5-8-15 3 Removed model 1503. Added models 1509 / 1515 (Pg 15) to the TOC. 8-10-15
More informationInstallation instructions for Aluminium Pantel, Pancode and Pancam C & T Telephone door access control units
Installation instructions for Aluminium Pantel, Pancode and Pancam C & T Telephone door access control units This manual and the information it contains may not, in whole or in part, be reproduced, copied,
More informationSL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.
SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming
More informationCM-500 SK 500 USER CODES KEYPAD
CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage
More informationV-9939C MICROPHONE ADAPTER
Issue 2 INTRODUCTION These instructions provide identification, installation, connection, operation and maintenance information for the Microphone Adapter. The is a Microphone Adapter designed to be used
More informationSS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)
GAINWISE TECHNOLOGY MANUAL GSM DOOR PHONE SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM) For your protection, read these instructions completely And keep them for future reference. SS91A-M GSM Door Phone
More information8. Electric Lock Connection
6. Switches Settings Total 6 bits in the switches can be configured. The switches can be modified either before or after installation. 1 3 5 6 (1) OFF (0) = = Bit1,Bit and Bit 3 are used for door station
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationThank you for purchasing the Digital Wireless Gate Intercom System. Digital technology provides
Introduction Thank you for purchasing the Digital Wireless Gate Intercom System. Digital technology provides clear communication with many interactive features. The hassle of wiring is eliminated with
More informationDP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time
DP2 Door Phone For Technical Assistance call the Manufacturers direct ph 0800 530 8645 9AM - 5PM West Coast Pacific Time NATCOMM USA LLC Supplier Code : NC TABLE OF CONTENTS Description Page 3 Door Phone
More informationEntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation
The EntraGuard Bronze is a residential telephone keypad entry system which allows a homeowner to communicate directly with visitors and provide access by using any phone extension in the home. Because
More informationEN TECHNICAL MANUAL. Audio module Art and Art. 1622L
EN TECHNICAL MANUAL Audio module Art. 1622 and Art. 1622L Warning Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
More informationGSM HOME SECURITY SYSTEM
Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More information232iLM Keypad Installation and Programming Instructions
232iLM Keypad Installation and Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6 1 / 2
More information9. Settings and Adjustments Switch Setting Chart Speech Levels Trades Clock Parts List 13
CONTENTS 1. Introduction 2 2. Features List 3 3. System Layout 4 4. Cable Requirements 5 5. Connections and Colour codes 6 6. Main Connections 7 7. Handset Connections 8 8. Flashing Beacon Connections
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationHI SEC Integrated Systems
Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing
More informationQuick Start Installation Guide
apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building
More informationSTR QwikBus 2 wire Color Video Intercom System
STR QwikBus 2 wire Color Video Intercom System Installation, Programming, and User s Manual Copyright 2007-2008, Alpha Communications, All Rights Reserved AWD121 Rev. 1.1 12/2007 STR QwikBus 2 wire Color
More informationInstalling Keypad and Backplate
Installing Keypad and Backplate Fig.1 Positioning of Fixing Holes and Cable Outlet Cable Outlet, Drill Diameter 10mm for Cable Access Remove the back plate, which is fitted to rear of the keypad, using
More informationVX2200 GSM MODULE ART Technical Manual. GSM Interface Module for the VX2200 Digital System ENG
ENG VX2200 GSM MODULE GSM Interface Module for the VX2200 Digital System ART. 2270 Technical Manual 66251225-EN V1.0-08/01/18 We recommend This equipment is installed by a Competent Electrician, Security
More information605 D E C T G I n t e r c o m
Installation & User Manual For 605 D E C T + 2. 4 G I n t e r c o m Wireless Video Intercom System Models 605AB, 605ABK P a g e 1 Contents Overview of system.pg 3 Site Survey.Pg 3 Mounting the Transmitter.Pg
More informationTechnical manual for two-family Kit Art. KAE5062
EN TECHNICAL MANUAL Technical manual for two-family Kit Art. KAE506 Warning Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards
More informationN-8000 SERIES IP INTERCOM SYSTEM
N-8000 SERIES IP INTERCOM SYSTEM Cutting-edge TOA technology for greater versatility and improved sound quality IP Network-Compatible Intercom System with Packet Audio Technology The TOA N-8000 Packet
More informationEZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY
EZTAG PROXIMITY AND KEYPAD DOOR ENTRY USER MANUAL www.espuk.com EZTAG Manual_Layout.indd 8//06 5:8:0 System Components Proximity and Reader 0 x Proximity Tags x Hex Key x Plastic wall plug x Countersunk
More informationCall Origination: Speaker/Mic: Camera: Mounting: Construction: Directory: Camera Aperture: Dimensions: Architects and Engineers Specification
Engineering Data 100/1F5 SERIES STAINLESS STEEL ENTY PANESL The Elvox Galileo Series Panels are designed to be durable and aesthetically pleasing. The 100 + 1F5 allows for pushbutton operation in a digital
More informationAPPLICATION PROCEDURE HOUSING INSTALLATION AND EQUIPMENT LOCATION
NH208TVU Amplifier and Power Supply Installation and Use Instructions Used with the HT2006 Series Inside Handset Intercom Stations and 1 or more Door Stations APPLICATION The NH208TVU series intercom system
More information9212i INSTALLATION. Stand-Alone Keypad. Instructions
INSTALLATION 9212i Stand-Alone Keypad Instructions Features: 4 Independent Outputs 4 Independent Timers All Outputs Assignable by Code On board 5 Amp Form C Relay 120 Users Remote Triggering Input Keypad
More informationMODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS
MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS Model KP-100 is a self-contained digital keypad. This keypad is suitable for residential, industrial, and commercial installations. It
More informationSoundwebTM. Installation Guide
111 SoundwebTM Soundweb TM 9010 Installation Guide Soundweb TM Regulatory Information v1.0 PW/JMK 21st March 1999 An example of this equipment has been tested and found to comply with the following European
More informationIntercom Installation The b-red. KIT audio entry control systems AKW200/201
Intercom Installation The b-red KIT audio entry control systems AKW200/201 What is the b-red 2 wire system? The b-red is an entry level intercom system, It makes use of digital technology and as such communication
More informationNew one-family and two-family kits.
New one-family and two-family kits. 7 LCD touchscreen One-family and two-family video entryphone kits. For the needs of simple video entryphone systems, new one-family and two-family kits are now available
More informationACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox
standalone ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox ACT 5e prox 2R.indd 1 19/02/2016 17:05:06 ACTstandalone Robust and Reliable. 1 ACT 5e prox 2R.indd 2 19/02/2016
More informationRTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions
Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS
More informationVideo Display Eteris. Installation manual 01GF-28W10
349340 Video Display Eteris Installation manual 01GF-28W10 2 Video Display Eteris Contents 1 Introduction 4 1.1 Warnings and tips 4 1.2 Package content 4 Installation manual 2 Description 5 2.1 Main functions
More information05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual
05/16-01 PC 343100 Monobloc Audio Digital Entrance Panel Installer manual 2 Contents Monobloc Audio Digital Entrance Panel 1 Introduction 4 1.1 Warnings and recommendations 4 2 Description 5 2.1 Main functions
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationGSMSK. Programming Manual. GSM Audio Intercom (GSM4K, GSMVRK, Digital GSM and Art.2270 GSM Interface Module) PC Programming Software ENG
18/11/16 08:35 ENG GSMSK GSM Audio Intercom (GSM4K, GSMVRK, Digital GSM and Art.2270 GSM Interface Module) PC Programming Software Enter Number Or Search Programming Manual 66251720-EN V1.3-23/02/18 We
More informationGeneral Catalogue. intercoms videophones access control 2014/2015
General Catalogue intercoms videophones access control 2014/2015 GENERAL CATALOGUE 3 General Catalogue intercoms videophones access control 2014/2015 4 GENERAL CATALOGUE Index 3000 Series 8 8000 Series
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More informationSee instructions to download and install the latest version of LinkBoxMB and the user's manual at
Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any
More information232iLM Keypad Installation & Programming Instructions
232iLM Keypad Installation & Programming Instructions Note: This product is designed to be installed and serviced by security and lock industry professionals. Specifications Case Dimensions: 6-1/2 L x