Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A

Size: px
Start display at page:

Download "Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A"

Transcription

1 erlin Gerin LV switch-disconnectors Interpact 40 to 2500A

2 2

3 LV switch-disconnectors Interpact from 40 to 2500 A 4 Typical low-voltage applications 6 Compact from 80 to 1250 A 7 asterpact from 800 to 6300 A 8 Product Panorama 9 Functions and characteristics 17 Installation and connection 47 Technical details 71 Product references 77 3

4 LV switch-disconnectors Interpact from 40 to 2500 A Interpact INS from 40 to 630A Circuit control and isolation. Industrial devices with modular profile from 40 to 160A. Industrial devices from 100 to 2500 A for installation in functional and universal switchboards. Front or lateral handle are available on the same device (up to INS250). Interpact INS switch-disconnector from 40 to 80 A Interpact INS switch-disconnector from 100 to 160 A Interpact INS250 switch-disconnector Interpact INS switch-disconnector from 400 to 630 A Interpact IN from 1000 to 2500 A Interpact IN1600 switch-disconnector 4

5 Compact from 80 to 1250 A (See Compact catalogue) Circuit control and isolation. Additional functions for safety, remote control and convenience: Earth-fault protection. N/X auxiliary releases. otor mechanism. Ammeter. Source changeover. Homogeneity with respect to Compact circuit breakers in the same switchboard. Compact switch-disconnector Compact switch-disconnector equipped with Vigi earth fault protection module Compact switch-disconnector with motor-mechanism N/X voltage release 5

6 LV switch-disconnectors Typical low-voltage applications source coupling switch-disconnector main power distribution board for commercial applications main power distribution board for industrial applications 1000 A ka 1600 A ka replacement source modular subdistribution board industrial distribution board automatic control panel 630 A ka 630 A 160 A : ka 400 A : ka source changeover system local isolation enclosure final distribution enclosure for commercial applications local isolation enclosure control panel local isolation enclosure 10 ka 25 ka ka 100 i 5 ka 5-15 ka 63 A 630 A 125 A N.B. adjacent to or built into the machine building utilities building final distribution continuous processes manufacturing processes and individual machines Legend asterpact Compact C Interpact INS Compact NS Vario Compact C Interpact IN Interpact INS ulti 9 6

7 Switch disconnectors for standby applications erlin Gerin asterpact, Compact C and Interpact IN switch-disconnectors. Current ratings: up to 6300A. Catalogue: asterpact, Compact C, Interpact (see following pages). ain power distribution boards for commercial and industrial applications erlin Gerin asterpact, Interpact INS/IN and Compact C switch-disconnectors. Current ratings: 400 to 1000 A for commercial applications and 400 to 1600 A for industrial applications. Catalogue: asterpact, Compact, Interpact (see following pages). asterbloc main power distribution board with asterpact switch-disconnectors Industrial switchboards and automatic-control panels erlin Gerin Interpact INS and Compact NS switch-disconnectors. Current ratings: up to 400A. Catalogue: Compact, Interpact (see following pages). Sub-distribution boards for modular products erlin Gerin Interpact INS and NG 125 switch-disconnectors. Current ratings: up to 160A. Standards: IEC BS EN , EN Catalogue: ulti 9, Interpact (see following pages). Local isolation enclosures erlin Gerin switch-disconnectors: Interpact INS and ulti 9 (low ratings). Interpact INS and Compact NS. Telemecanique switch-disconnectors (12 to 175A). Current ratings: up to 63 A (low ratings), up to 630A (industry). Catalogue: Compact, Interpact (see following pages), Telemecanique. Prisma P & G sub-distribution board with Interpact switch-disconnectors Small distribution enclosures for commercial applications erlin Gerin Interpact INS and ulti 9 switch-disconnectors. Current ratings: up to 63A Catalogue: ulti 9, Interpact (see following pages). Control panels Telemecanique Vario switch-disconnectors. Current ratings: up to 60/80A. Catalogue: Telemecanique. Local isolation enclosures (manufacturing processes and individual machines) Interpact INS and Telemecanique Vario switch-disconnectors. Current ratings: up to 63/80 A (Vario) and > 63/80 A (Interpact INS). Catalogue: Interpact (see following pages), Telemecanique. Isobar 4 final distribution boards using Interpact at 250Amp 7

8 LV switch-disconnectors asterpact from 800 to 6300A (See asterpact catalogue) Circuit control and isolation. High making capacity and electrodynamic withstand. Additional functions for safety and convenience: N/X auxiliary releases. XF closing release. otor mechanism. Source changeover. asterpact switch-disconnector 8

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time

Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation

More information

Prisma Plus System P Cubicles up to 4000 A

Prisma Plus System P Cubicles up to 4000 A Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution

More information

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.

Low voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation. Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation

More information

SPM Series Plug-in Surge Protection

SPM Series Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

4. CIRCUIT BREAKERS. Functional Emergency Switching

4. CIRCUIT BREAKERS. Functional Emergency Switching 4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

Air-insulated medium-voltage secondary distribution switchgear

Air-insulated medium-voltage secondary distribution switchgear DISTRIBUTION SOLUTIONS Air-insulated medium-voltage secondary distribution switchgear Compact size Complete solution Factory tested Air-insulated medium-voltage secondary distribution switchgear The ABB

More information

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016 Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave

More information

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by

More information

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage

More information

Manual source-changeover systems Possible combinations

Manual source-changeover systems Possible combinations Manual source-changeoer systems Possile cominations A manual source-changeoer system can e installed on two or three manually-operated and mechanically interlocked circuit reakers or switch-disconnectors.

More information

3 Design of the electrical installation protection system

3 Design of the electrical installation protection system J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design

More information

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Build electrical installations more efficiently Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Develop your business efficiency w Switchboards that are safe

More information

Disconnect Switches. Safe Switching and Disconnecting

Disconnect Switches. Safe Switching and Disconnecting IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as

More information

Low Voltage Catalogue Compact NS. Circuit breakers and switch-disconnectors from 630b to 3200 A

Low Voltage Catalogue Compact NS. Circuit breakers and switch-disconnectors from 630b to 3200 A Low Voltage Catalogue 2013 Compact NS Circuit breakers and switch-disconnectors from 630b to 3200 A Compact NS Setting the standard, once again... The launch of Schneider Electric Compact NS in 1994 revolutionised

More information

RB60 RANGE. Miniature circuit breakers

RB60 RANGE. Miniature circuit breakers RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com www ElectricalPartManuals com multi 9, systematically Terminal distribution applications are large: housing, service sector and industry, and the needs are constantly changing Reconciling security and

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

SPM Series. Plug-in Surge Protection

SPM Series. Plug-in Surge Protection SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects

More information

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct

Compact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct push to trip Io Ir.8.9.9.93.7 1.88.95.63.85.98.5.8 1 Ir Im xin xio Ir Im a a.7.63.5.8.9 1 xin Io push to trip Ir.9.93.88.95.85.98.8 1 xio alarm 90 105 alarm 90 105 Im 5 6 4 7 3 8 2 10 xir Im 5 6 4 7 3

More information

Multi 9 switchgear NSA, INS, NG125

Multi 9 switchgear NSA, INS, NG125 N interpact INS 125 5 8 I. ON Installation and connection in the switchboard Multi 9 switchgear NSA, INS, NG125 051279-70% Description of device number per row (modules = 9 mm) E37025(MGA+BT) Multi 9 switchgear

More information

NW08 to NW63 fixed circuit breakers Circuit breakers

NW08 to NW63 fixed circuit breakers Circuit breakers fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b

More information

RCDs RCBOs MCBs Isolating Switches Switchboards

RCDs RCBOs MCBs Isolating Switches Switchboards RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable

More information

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards) ////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world

More information

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities. KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA

More information

Coordination of Surge protection devices

Coordination of Surge protection devices Coordination of Surge protection devices Design guide Surge arresters for commercial and industrial buildings Surge protection devices: how to choose them? coordination How to choose surge protection devices?

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

Reinforced discrimination

Reinforced discrimination Reinforced discrimination Compact NSX Additional characteristics Contents Presentation Functions and characteristics A- Installation recommendations B- Dimensions and connection C- Wiring diagrams D- Compact

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing

More information

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000

More information

Pan assemblies and installation accessories

Pan assemblies and installation accessories Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars

More information

Source-changeover systems Presentation

Source-changeover systems Presentation Functions and characteristics Source-changeover systems Presentation PB100843 Manual source-changeover system This is the most simple type. t is controlled manually y an operator and consequently the time

More information

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches. comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power

More information

Lightning and Surge Arresters

Lightning and Surge Arresters Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement

More information

Brochure. Official Distributor In Iraq

Brochure. Official Distributor In Iraq INANA Brochure SHOWROOM Official Distributor In Iraq 2006 Contents -1- Contents:- 1.Inana Showroom 1.1. Profile 1.2. Products 1.3. Management 2. 2.1. Profile 2.2. Markets 2.3. Offer 2.4. Brands 2.4.1.

More information

Common Departures Interconnecting Facilities Requirements

Common Departures Interconnecting Facilities Requirements Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low

More information

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct

More information

Control Panel Technical Guide. How to choose the circuit breaker and transfer switch for a generator set

Control Panel Technical Guide. How to choose the circuit breaker and transfer switch for a generator set Control Panel Technical Guide How to choose the circuit breaker and transfer switch for a generator set Standby power supply by generator set Everything has been planned so that this will not happen If

More information

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo Medium voltage switchgear With fixed pattern circuit breaker GenieEvo Simple and highly reliable switchgear for primary and secondary distribution GenieEvo is an indoor switchgear assembly circuit breaker

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Low Voltage electrical distribution Catalogue Prisma PH

Low Voltage electrical distribution Catalogue Prisma PH Low Voltage electrical distribution Catalogue 2014 Prisma PH Prisma PH Contents Index 2 Electrical switchboards... Up to 4000 A 4 Prisma PH functional system 6 Switchgears 7 Linergy LGYE 8 Horizontal

More information

CAPABILITY STATEMENT. A full list of our services.

CAPABILITY STATEMENT. A full list of our services. CAPABILITY STATEMENT A full list of our services. About Us MVLV Power Solutions Pty Ltd is a privately owned Western Australian based company, specialising in the Design and Manufacture of Electrical Switchboards

More information

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC

Interpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC 28901 2890 28905 28909 28911 2891 116 1167 1169 1171 117 1175 171 159 161 16 165 167 169 111 115 11 117 119 1151 115 1155 Load s Interpact Switch-disconnectors INS/INV0 to 2500 A The Interpact INS/INV

More information

SENTRON ATC Automatic Transfer Control Device

SENTRON ATC Automatic Transfer Control Device Siemens A 2010 SENTRON - SENTRON switching, protection and measuring devices The SENTRON, when equipped with two motor-driven circuit breakers, serves as a transfer system that automatically or manually

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

Merlin Gerin GenieEvo metalclad MV switchgear kV Selection guide

Merlin Gerin GenieEvo metalclad MV switchgear kV Selection guide Merlin Gerin GenieEvo metalclad MV switchgear 3.3-13.8kV Selection guide GenieEvo selection guide Contents Section one Product overview 5 Section two Introduction 15 Section three Network functions Summary

More information

DSE201, DSE201 M Compact design with enhanced protection

DSE201, DSE201 M Compact design with enhanced protection DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD. (INDIA) VT. LTD. 5. INCOMING SULY CONDUCTOR TERMINATIONS AND DEVICES FOR DISCONNECTING AND SWITCHING OFF 5.1 Incoming supply conductor terminations The electrical equipment of the machine shall have only

More information

THE SURGE PROTECTION SOLUTION

THE SURGE PROTECTION SOLUTION THE SOLUTION Unique product features and benefits never before offered in the surge protection industry POWER QUALITY INTERNATIONAL, LLC 2404 Merchant Ave., Odessa, Florida, USA 33556 (888) 539-7712 PowerQuality.net

More information

Adaptors Busplug Low Voltage Switchboard Equipment

Adaptors Busplug Low Voltage Switchboard Equipment Busplug Adaptors Low Voltage Switchboard Equipment Publication BA 2012 CONTENTS Descriptive Advantages of Busplugs 2 General Description 3 Use of Busplugs Adaptors 3 Construction 4 Technical Standards

More information

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually

More information

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices

Siemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and

More information

Low Voltage Catalogue Prisma G. Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A

Low Voltage Catalogue Prisma G. Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A Low Voltage Catalogue 2013 Prisma G Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A Overview To respond to increasing building requirements Improve the continuity of

More information

Surge Protection Devices and Surge Protection Kit

Surge Protection Devices and Surge Protection Kit Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down

More information

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique Protection and control epam range epam T Merlin Gerin quare D Telemecanique presentation contents page presentation connection characteristics installation ordering information epam T. on in in in in in

More information

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;

More information

DOCA0093EN-00 10/2015. ULP System. ULP (Universal Logic Plug) System User Guide 10/2015 DOCA0093EN-00.

DOCA0093EN-00 10/2015. ULP System. ULP (Universal Logic Plug) System User Guide 10/2015 DOCA0093EN-00. ULP System DOCA0093EN-00 10/2015 ULP System ULP (Universal Logic Plug) System User Guide DOCA0093EN-00 10/2015 www.schneider-electric.com The information provided in this documentation contains general

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection OVR Range FRSOX 0100 03 GB ABB Lightning Protection Group 1 Main causes of transient overvoltages The solution: ABB OVR Surge Protective Device Range Lightning strike A lightning

More information

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES

SOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:

More information

IEC & 2 standard. The reference for safe and reliable LV switchboards

IEC & 2 standard. The reference for safe and reliable LV switchboards IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC

More information

DC-Switch With G20S/G20. next

DC-Switch With G20S/G20.   next DC-Switch With knife contacts G2S/G2 www.krausnaimer.com next Content The most important technical data: G2S / G2... 3 Electrical data of ON/OFF-Swichtes: G2S / G2... 4 Electrical data of Change Over Switches:

More information

ic60n RCBO 30 ma IEC , IEC , AS/NZS

ic60n RCBO 30 ma IEC , IEC , AS/NZS ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of

More information

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A

MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,

More information

Medium Voltage Distribution Catalogue GenieEvo range. Air Insulated MV Switchgear kv

Medium Voltage Distribution Catalogue GenieEvo range. Air Insulated MV Switchgear kv Medium Voltage Distribution Catalogue 2015 GenieEvo range Air Insulated MV Switchgear 3.3-13.8 kv Medium Voltage Distribution GenieEvo Your requirements Peace of mind Energy availability Safety GenieEvo

More information

SIPROTEC 5 Application Note

SIPROTEC 5 Application Note www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-001: Properties and Functional Structure Answers for infrastructure and cities SIPROTEC 5 Properties SIPROTEC 5 - Application: SIP5-APN-001

More information

Remote contact signaling available. visual status indication

Remote contact signaling available. visual status indication Effective January 2016 Supersedes August 2013 BUSSMANN SERIES PV PRO three module photovoltaic surge protective devices for 600 and 1000Vdc systems Remote contact signaling available easyid local visual

More information

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits 01 Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv PM103255 Energy supply security is our permanent challenge. At Schneider Electric, we are constantly developing and improving our products

More information

NU-LEC. Loop Automation. Reclosers & Sectionalizers

NU-LEC. Loop Automation. Reclosers & Sectionalizers NU-LEC Loop Automation Reclosers & Sectionalizers 1 NU-LEC LLC NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd. Sales and service center for United States, Canada, and the Caribbean. Warehouse

More information

Modular switch disconnectors and modular change-over switches

Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability

More information

B60 Domestic Voltage Optimisation Unit. Installation Manual

B60 Domestic Voltage Optimisation Unit. Installation Manual Govna B60PVM Voltage Optimisation Unit Govna B60PVM Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Web: www.renewableenergyhub.co.uk Email: info@renewableenergyhub.co.uk Phone: 0845 862

More information

ETITEC - Lightning and Surge Arresters

ETITEC - Lightning and Surge Arresters ETITEC Lightning and Surge Arresters Overvoltage protection selection ETITEC selection Define system data: U max Uc > 1,2 x U max External lightning protection exist? NO Apply ETITEC C on string and on

More information

R3&A Limited, Cobourg, ON

R3&A Limited, Cobourg, ON R3&A imited, Cobourg, ON ightning and Surge Protection Devices for North America Easy Choice POWER SUPPY SYSTEMS Main distribution board (Category C) Class I ightning current arrester Subdistribution board

More information

Compact NSX communication

Compact NSX communication Functions and characteristics Compact NSX communication Communications modules All Compact NSX devices can be equipped with the communication function via a prewired connection system and a Modbus network

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

Surge & Filter Protection Addressing your industrial power quality needs.

Surge & Filter Protection Addressing your industrial power quality needs. Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin

More information

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Voltage Panels and Enclosures designed and built with

More information

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay

High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay IE ON RESET.5 X1 t IE X1.6%.2.4.8 1.6 X1.1s.2.4.8 1.6 X2 OFF ON S1 S2 IRI1-ES IRI1-ES C&S Electric Limited (Protection & Control Division) Contents

More information

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A) IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Reliable Switchgear from One Proven Supplier

Reliable Switchgear from One Proven Supplier Catalogue Industrial Switchgear 2007/2008 Reliable Switchgear from One Proven Supplier Xtra Combinations Xtra Combinations from Moeller offers a range of products and services, enabling the best possible

More information

Communication COM option in Masterpact

Communication COM option in Masterpact CT CCM modbus CD CE Functions and characteristics Communication COM option in 056431 056401 The COM option is required for integration of the circuit breaker or switch-disconnector in a supervision system.

More information

BCM ULP Breaker Communication Module

BCM ULP Breaker Communication Module DOCA0152EN-00 BCM ULP Breaker Communication Module Firmware Version 4.1.9 Release Note 05/2018 The information provided in this documentation contains general descriptions and/or technical characteristics

More information

DOC Electrical Installation Calculation and Dimensioning

DOC Electrical Installation Calculation and Dimensioning Help ABB SACE A Division of ABB S.p.A., MK-TO, 2011 DOC Electrical Installation Calculation and Dimensioning February 14, 2011 Slide 1 Contents Use cases ABB Software Desktop February 14, 2011 Slide 2

More information

P Series PlexPower Distribution Panelboards Increased Safety

P Series PlexPower Distribution Panelboards Increased Safety Applications The P Series PowerPlex panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Other

More information

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available KMP A3 Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available High power switchgear systems For primary applications The name MediPower represents powerful medium voltage energy distribution

More information

B60 Domestic Voltage Optimisation Unit

B60 Domestic Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,

More information

Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS

Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS www.moeller.net Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Reliably and safely controlling, switching and managing power. In industry, in buildings and

More information

Solutions guide for commercial buildings, carports, and decentralised power plants. using Conext TL small three-phase PV inverters

Solutions guide for commercial buildings, carports, and decentralised power plants. using Conext TL small three-phase PV inverters Solutions guide for commercial buildings, carports, and decentralised power plants using Conext TL small three-phase PV inverters Schneider Electric, a bankable partner you can trust Table of contents

More information

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault

More information

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Build electrical installations more efficiently. Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A

Build electrical installations more efficiently. Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A Build electrical installations more efficiently Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A Develop your business efficiency wit Switchboards that are safe With

More information

2 Principle of lightning protection

2 Principle of lightning protection 2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical

More information

REYROLLE 2RMLG. Operating Recommendations

REYROLLE 2RMLG. Operating Recommendations 2RMLG Operating Recommendations SAFETY The commissioning and maintenance of protection equipment should only be carried out by skilled personnel trained in protective relay operation and capable of observing

More information

High Safety low voltage switchgears For maximum requirements far beyond all standards.

High Safety low voltage switchgears For maximum requirements far beyond all standards. High Safety low voltage switchgears For maximum requirements far beyond all standards. High Safety solutions From the specialist for arc fault protection For years, the names ModuPro and ModuCon have stood

More information

MMLG 01, 02, 03, 04 MMLB01

MMLG 01, 02, 03, 04 MMLB01 MMLG 01, 02, 03, 04 MMLB01 Technical Data Test Blocks and Test Plugs Publication Reference: MMLG_MMLB/EN/TD/B - ALSTOM 2015. All rights reserved. Information contained in this document is indicative only.

More information

SWITCH DISCONNECTORS 11

SWITCH DISCONNECTORS 11 SWITCH DISCONNECTORS 16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty