Merlin Gerin LV switch-disconnectors Interpact 40 to 2500A
|
|
- Cora Lyons
- 6 years ago
- Views:
Transcription
1 erlin Gerin LV switch-disconnectors Interpact 40 to 2500A
2 2
3 LV switch-disconnectors Interpact from 40 to 2500 A 4 Typical low-voltage applications 6 Compact from 80 to 1250 A 7 asterpact from 800 to 6300 A 8 Product Panorama 9 Functions and characteristics 17 Installation and connection 47 Technical details 71 Product references 77 3
4 LV switch-disconnectors Interpact from 40 to 2500 A Interpact INS from 40 to 630A Circuit control and isolation. Industrial devices with modular profile from 40 to 160A. Industrial devices from 100 to 2500 A for installation in functional and universal switchboards. Front or lateral handle are available on the same device (up to INS250). Interpact INS switch-disconnector from 40 to 80 A Interpact INS switch-disconnector from 100 to 160 A Interpact INS250 switch-disconnector Interpact INS switch-disconnector from 400 to 630 A Interpact IN from 1000 to 2500 A Interpact IN1600 switch-disconnector 4
5 Compact from 80 to 1250 A (See Compact catalogue) Circuit control and isolation. Additional functions for safety, remote control and convenience: Earth-fault protection. N/X auxiliary releases. otor mechanism. Ammeter. Source changeover. Homogeneity with respect to Compact circuit breakers in the same switchboard. Compact switch-disconnector Compact switch-disconnector equipped with Vigi earth fault protection module Compact switch-disconnector with motor-mechanism N/X voltage release 5
6 LV switch-disconnectors Typical low-voltage applications source coupling switch-disconnector main power distribution board for commercial applications main power distribution board for industrial applications 1000 A ka 1600 A ka replacement source modular subdistribution board industrial distribution board automatic control panel 630 A ka 630 A 160 A : ka 400 A : ka source changeover system local isolation enclosure final distribution enclosure for commercial applications local isolation enclosure control panel local isolation enclosure 10 ka 25 ka ka 100 i 5 ka 5-15 ka 63 A 630 A 125 A N.B. adjacent to or built into the machine building utilities building final distribution continuous processes manufacturing processes and individual machines Legend asterpact Compact C Interpact INS Compact NS Vario Compact C Interpact IN Interpact INS ulti 9 6
7 Switch disconnectors for standby applications erlin Gerin asterpact, Compact C and Interpact IN switch-disconnectors. Current ratings: up to 6300A. Catalogue: asterpact, Compact C, Interpact (see following pages). ain power distribution boards for commercial and industrial applications erlin Gerin asterpact, Interpact INS/IN and Compact C switch-disconnectors. Current ratings: 400 to 1000 A for commercial applications and 400 to 1600 A for industrial applications. Catalogue: asterpact, Compact, Interpact (see following pages). asterbloc main power distribution board with asterpact switch-disconnectors Industrial switchboards and automatic-control panels erlin Gerin Interpact INS and Compact NS switch-disconnectors. Current ratings: up to 400A. Catalogue: Compact, Interpact (see following pages). Sub-distribution boards for modular products erlin Gerin Interpact INS and NG 125 switch-disconnectors. Current ratings: up to 160A. Standards: IEC BS EN , EN Catalogue: ulti 9, Interpact (see following pages). Local isolation enclosures erlin Gerin switch-disconnectors: Interpact INS and ulti 9 (low ratings). Interpact INS and Compact NS. Telemecanique switch-disconnectors (12 to 175A). Current ratings: up to 63 A (low ratings), up to 630A (industry). Catalogue: Compact, Interpact (see following pages), Telemecanique. Prisma P & G sub-distribution board with Interpact switch-disconnectors Small distribution enclosures for commercial applications erlin Gerin Interpact INS and ulti 9 switch-disconnectors. Current ratings: up to 63A Catalogue: ulti 9, Interpact (see following pages). Control panels Telemecanique Vario switch-disconnectors. Current ratings: up to 60/80A. Catalogue: Telemecanique. Local isolation enclosures (manufacturing processes and individual machines) Interpact INS and Telemecanique Vario switch-disconnectors. Current ratings: up to 63/80 A (Vario) and > 63/80 A (Interpact INS). Catalogue: Interpact (see following pages), Telemecanique. Isobar 4 final distribution boards using Interpact at 250Amp 7
8 LV switch-disconnectors asterpact from 800 to 6300A (See asterpact catalogue) Circuit control and isolation. High making capacity and electrodynamic withstand. Additional functions for safety and convenience: N/X auxiliary releases. XF closing release. otor mechanism. Source changeover. asterpact switch-disconnector 8
Catalogue G System Pack, wall mount and floor standing enclosures. Prisma Plus LV Switchboards Devised to save time
Catalogue G System Pack, wall mount and floor standing enclosures Prisma Plus LV Switchboards Devised to save time General contents Index 2 General presentation 8 Pack 10 17 General presentation Installation
More informationPrisma Plus System P Cubicles up to 4000 A
Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution
More informationLow voltage. NG to 160 A. Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation.
Low voltage NG160 16 to 160 A Modular incoming circuit breakers and switch-disconnectors for DIN-panel installation Catalogue 2010 NG160 circuit breaker Ready to install NG160 General contents Presentation
More informationSPM Series Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More information4. CIRCUIT BREAKERS. Functional Emergency Switching
4. CIRCUIT BREAKERS The circuit breaker/disconnector fulfils all of the basic switchgear functions, while, by means of accessories, numerous other possibilities exist. As shown in table H2-19 the circuit
More informationC60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)
DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables
More informationAir-insulated medium-voltage secondary distribution switchgear
DISTRIBUTION SOLUTIONS Air-insulated medium-voltage secondary distribution switchgear Compact size Complete solution Factory tested Air-insulated medium-voltage secondary distribution switchgear The ABB
More informationLow voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016
Low voltage Acti 9 the efficiency you deserve Catalogue 03/2016 schneider-electric.com 1 and 2 LV surge s 1 and 2 LV surge s (cont.) The 1 range of surge s meets the normative withstand capability of wave
More informationSPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters
The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects of transient over voltages caused by
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationManual source-changeover systems Possible combinations
Manual source-changeoer systems Possile cominations A manual source-changeoer system can e installed on two or three manually-operated and mechanically interlocked circuit reakers or switch-disconnectors.
More information3 Design of the electrical installation protection system
J - Protection against voltage surges in LV 3 Design of the electrical To protect an electrical installation in a building, simple rules apply for the choice of b (s); b its protection system. 3.1 Design
More informationBuild electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A
Build electrical installations more efficiently Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Develop your business efficiency w Switchboards that are safe
More informationDisconnect Switches. Safe Switching and Disconnecting
IB105-UK_U1_U4_Pfade.indd 2-3 14.04.2005, 16:51:30 Disconnect Switches Safe Switching and Disconnecting Disconnect Switches from Salzer are hand-operated switchgear for main circuits and are offered as
More informationLow Voltage Catalogue Compact NS. Circuit breakers and switch-disconnectors from 630b to 3200 A
Low Voltage Catalogue 2013 Compact NS Circuit breakers and switch-disconnectors from 630b to 3200 A Compact NS Setting the standard, once again... The launch of Schneider Electric Compact NS in 1994 revolutionised
More informationRB60 RANGE. Miniature circuit breakers
RB60 RANGE Miniature circuit breakers POWER 2015 RB60 range Miniature circuit breakers Miniature circuit breakers for circuit protection The miniature circuit breakers RB60 are designed for the protection
More informationwww. ElectricalPartManuals. com
www ElectricalPartManuals com multi 9, systematically Terminal distribution applications are large: housing, service sector and industry, and the needs are constantly changing Reconciling security and
More informationSwitch Disconnectors, Main and EMERGENCY-STOP Switches
General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)
More informationSPM Series. Plug-in Surge Protection
SPM Series Plug-in Surge Protection The SPM series of modular surge protection devices provides protection of equipment connected to incoming low voltage AC power supplies against the damaging effects
More informationCompact NS 100/400 in the duct Interpact INS 250/400 in the duct Interpact INV 250/400 in the duct
push to trip Io Ir.8.9.9.93.7 1.88.95.63.85.98.5.8 1 Ir Im xin xio Ir Im a a.7.63.5.8.9 1 xin Io push to trip Ir.9.93.88.95.85.98.8 1 xio alarm 90 105 alarm 90 105 Im 5 6 4 7 3 8 2 10 xir Im 5 6 4 7 3
More informationMulti 9 switchgear NSA, INS, NG125
N interpact INS 125 5 8 I. ON Installation and connection in the switchboard Multi 9 switchgear NSA, INS, NG125 051279-70% Description of device number per row (modules = 9 mm) E37025(MGA+BT) Multi 9 switchgear
More informationNW08 to NW63 fixed circuit breakers Circuit breakers
fixed circuit breakers Circuit breakers DB404362.eps DB404363.eps A Masterpact fixed circuit breaker is described by 4 catalogue numbers corresponding to: b the basic circuit breaker b a control unit b
More informationRCDs RCBOs MCBs Isolating Switches Switchboards
RCDs RCBOs MCBs Isolating Switches Switchboards 1300 722 275 F: 1300 738 717 RCD 4 Pole 6KA RCDs monitors at all times the current flow and will cut the electrical supply in case of an imbalance. Suitable
More information////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)
////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world
More informationSiemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.
KD Switch Disconnectors SENTRON Edition December 01 Answers for infrastructure and cities. Related catalogs Low-Voltage Power Distribution and LV 10 Electrical Installation Technology SENTRON SIVACON ALPHA
More informationCoordination of Surge protection devices
Coordination of Surge protection devices Design guide Surge arresters for commercial and industrial buildings Surge protection devices: how to choose them? coordination How to choose surge protection devices?
More informationMULTI 9 System Catalog UL Recognized C60N Supplementary Protectors
UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5
More informationReinforced discrimination
Reinforced discrimination Compact NSX Additional characteristics Contents Presentation Functions and characteristics A- Installation recommendations B- Dimensions and connection C- Wiring diagrams D- Compact
More informationMULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors
B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors
More informationPRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters
Type 1 and 2 LV surge s The Type 1 range of surge s meets the normative withstand capability of wave type 10/350 μs (8/20 μs for Type 2 surge s). It is suitable for use with, TN-C and 230 V IT earthing
More informationVarius SUMMARY OF MODELS OF HRC FUSE-LINKS
SUMMARY OF MODELS OF HRC FUSE-LINKS PNA000 PHNA000 PNA00 PHNA00 Rated current I n up to A up to 0 A up to A up to 0 A Rated voltage U n AC 00 V, 00 V 90 V 00 V 90 V DC 0 V 0 V 0 V 0 V Fuse-link size 000
More informationPan assemblies and installation accessories
Contents Section 10 Pan assemblies and installation accessories SP&N pan assemblies 124 SP&N door and cover 124 TP&N pan assemblies 125 TP&N door and cover 125 Multiclip busbar and Polybloc 126 Comb busbars
More informationSource-changeover systems Presentation
Functions and characteristics Source-changeover systems Presentation PB100843 Manual source-changeover system This is the most simple type. t is controlled manually y an operator and consequently the time
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationLightning and Surge Arresters
Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement
More informationBrochure. Official Distributor In Iraq
INANA Brochure SHOWROOM Official Distributor In Iraq 2006 Contents -1- Contents:- 1.Inana Showroom 1.1. Profile 1.2. Products 1.3. Management 2. 2.1. Profile 2.2. Markets 2.3. Offer 2.4. Brands 2.4.1.
More informationCommon Departures Interconnecting Facilities Requirements
Welcome to our e-rew Express. In our last issue, we discussed the common departures on metering installation requirements. This time, we would like to discuss the common departures on the customer low
More informationIDE Load break switches for machine control Remotely trippable switch from 32 to 160 A
The solution for Load break switches > Industry. > Non critical buildings. > Public Access Sites. > High Rise Buildings. ide_021_a_1_cat ide_022_a_1_cat IDE 4x40 A External operation IDE 4x40 A Direct
More informationControl Panel Technical Guide. How to choose the circuit breaker and transfer switch for a generator set
Control Panel Technical Guide How to choose the circuit breaker and transfer switch for a generator set Standby power supply by generator set Everything has been planned so that this will not happen If
More informationMedium voltage switchgear With fixed pattern circuit breaker GenieEvo
Medium voltage switchgear With fixed pattern circuit breaker GenieEvo Simple and highly reliable switchgear for primary and secondary distribution GenieEvo is an indoor switchgear assembly circuit breaker
More informationAThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.
www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer
More informationLow Voltage electrical distribution Catalogue Prisma PH
Low Voltage electrical distribution Catalogue 2014 Prisma PH Prisma PH Contents Index 2 Electrical switchboards... Up to 4000 A 4 Prisma PH functional system 6 Switchgears 7 Linergy LGYE 8 Horizontal
More informationCAPABILITY STATEMENT. A full list of our services.
CAPABILITY STATEMENT A full list of our services. About Us MVLV Power Solutions Pty Ltd is a privately owned Western Australian based company, specialising in the Design and Manufacture of Electrical Switchboards
More informationInterpact Switch-disconnectors INS/INV40 to 2500 A. INS/INV Standard version with black handle - Fixed /FC
28901 2890 28905 28909 28911 2891 116 1167 1169 1171 117 1175 171 159 161 16 165 167 169 111 115 11 117 119 1151 115 1155 Load s Interpact Switch-disconnectors INS/INV0 to 2500 A The Interpact INS/INV
More informationSENTRON ATC Automatic Transfer Control Device
Siemens A 2010 SENTRON - SENTRON switching, protection and measuring devices The SENTRON, when equipped with two motor-driven circuit breakers, serves as a transfer system that automatically or manually
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationMerlin Gerin GenieEvo metalclad MV switchgear kV Selection guide
Merlin Gerin GenieEvo metalclad MV switchgear 3.3-13.8kV Selection guide GenieEvo selection guide Contents Section one Product overview 5 Section two Introduction 15 Section three Network functions Summary
More informationDSE201, DSE201 M Compact design with enhanced protection
DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection
More informationMiniature Circuit-Breaker IEC Series 8562
> 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips
More informationINSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.
(INDIA) VT. LTD. 5. INCOMING SULY CONDUCTOR TERMINATIONS AND DEVICES FOR DISCONNECTING AND SWITCHING OFF 5.1 Incoming supply conductor terminations The electrical equipment of the machine shall have only
More informationTHE SURGE PROTECTION SOLUTION
THE SOLUTION Unique product features and benefits never before offered in the surge protection industry POWER QUALITY INTERNATIONAL, LLC 2404 Merchant Ave., Odessa, Florida, USA 33556 (888) 539-7712 PowerQuality.net
More informationAdaptors Busplug Low Voltage Switchboard Equipment
Busplug Adaptors Low Voltage Switchboard Equipment Publication BA 2012 CONTENTS Descriptive Advantages of Busplugs 2 General Description 3 Use of Busplugs Adaptors 3 Construction 4 Technical Standards
More informationMaximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches
Series 300 Power Transfer Switches Maximum Reliability & Excellent Value With a Series 300 Transfer Switch, you get a product backed by ASCO Power Technologies, the industry leader responsible for virtually
More informationSiemens AG 2017 SENTRON. 3LD Main Control and EMERGENCY-STOP Switches. Catalog Extract LV 10. Edition 10/2017. siemens.com/switching-devices
Siemens AG 201 SENTRON 3LD Main Control and EMERGENCY-STOP Switches Catalog Extract LV 10 Edition 10/201 siemens.com/switching-devices Siemens AG 201 Related catalogs Low-Voltage Power Distribution and
More informationLow Voltage Catalogue Prisma G. Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A
Low Voltage Catalogue 2013 Prisma G Wall-mounted and floor standing enclosures for Electrical Distribution up to 630 A Overview To respond to increasing building requirements Improve the continuity of
More informationSurge Protection Devices and Surge Protection Kit
Surge and Surge Kit SPD s protect electrical and electronic equipment against transients, originating from lightning, switching of transformers, lighting and motors 3. Main protection - class 3 To cut-down
More informationProtection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique
Protection and control epam range epam T Merlin Gerin quare D Telemecanique presentation contents page presentation connection characteristics installation ordering information epam T. on in in in in in
More informationMNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager
MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;
More informationDOCA0093EN-00 10/2015. ULP System. ULP (Universal Logic Plug) System User Guide 10/2015 DOCA0093EN-00.
ULP System DOCA0093EN-00 10/2015 ULP System ULP (Universal Logic Plug) System User Guide DOCA0093EN-00 10/2015 www.schneider-electric.com The information provided in this documentation contains general
More informationOvervoltage Protection
Overvoltage Protection OVR Range FRSOX 0100 03 GB ABB Lightning Protection Group 1 Main causes of transient overvoltages The solution: ABB OVR Surge Protective Device Range Lightning strike A lightning
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationIEC & 2 standard. The reference for safe and reliable LV switchboards
IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC
More informationDC-Switch With G20S/G20. next
DC-Switch With knife contacts G2S/G2 www.krausnaimer.com next Content The most important technical data: G2S / G2... 3 Electrical data of ON/OFF-Swichtes: G2S / G2... 4 Electrical data of Change Over Switches:
More informationic60n RCBO 30 ma IEC , IEC , AS/NZS
ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of
More informationMMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A
AUTOMATION MMLB 01/MMLB 02 Multi-finger Test Plug/ Single-finger Test Plug Technical Data MMLB_EN_TD_A GRID Note: The technical manual for this device gives instructions for its installation, commissioning,
More informationMedium Voltage Distribution Catalogue GenieEvo range. Air Insulated MV Switchgear kv
Medium Voltage Distribution Catalogue 2015 GenieEvo range Air Insulated MV Switchgear 3.3-13.8 kv Medium Voltage Distribution GenieEvo Your requirements Peace of mind Energy availability Safety GenieEvo
More informationLV power circuit breakers and switch-disconnectors. Masterpact NT and NW Merlin Gerin. << Back. Catalogue. Building a New Electric World
More information
SIPROTEC 5 Application Note
www.siemens.com/protection SIPROTEC 5 Application Note SIP5-APN-001: Properties and Functional Structure Answers for infrastructure and cities SIPROTEC 5 Properties SIPROTEC 5 - Application: SIP5-APN-001
More informationRemote contact signaling available. visual status indication
Effective January 2016 Supersedes August 2013 BUSSMANN SERIES PV PRO three module photovoltaic surge protective devices for 600 and 1000Vdc systems Remote contact signaling available easyid local visual
More informationGHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits
01 Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv PM103255 Energy supply security is our permanent challenge. At Schneider Electric, we are constantly developing and improving our products
More informationNU-LEC. Loop Automation. Reclosers & Sectionalizers
NU-LEC Loop Automation Reclosers & Sectionalizers 1 NU-LEC LLC NU-LEC LLC is a wholly unit of NU-LEC Industries, Pty, Ltd. Sales and service center for United States, Canada, and the Caribbean. Warehouse
More informationModular switch disconnectors and modular change-over switches
Modular switch disconnectors and modular change-over switches Modular switch disconnectors and modular change-over switches The new generation of modular switch disconnectors is guarantee of reliability
More informationB60 Domestic Voltage Optimisation Unit. Installation Manual
Govna B60PVM Voltage Optimisation Unit Govna B60PVM Voltage Optimisation Unit B60 Domestic Voltage Optimisation Unit Web: www.renewableenergyhub.co.uk Email: info@renewableenergyhub.co.uk Phone: 0845 862
More informationETITEC - Lightning and Surge Arresters
ETITEC Lightning and Surge Arresters Overvoltage protection selection ETITEC selection Define system data: U max Uc > 1,2 x U max External lightning protection exist? NO Apply ETITEC C on string and on
More informationR3&A Limited, Cobourg, ON
R3&A imited, Cobourg, ON ightning and Surge Protection Devices for North America Easy Choice POWER SUPPY SYSTEMS Main distribution board (Category C) Class I ightning current arrester Subdistribution board
More informationCompact NSX communication
Functions and characteristics Compact NSX communication Communications modules All Compact NSX devices can be equipped with the communication function via a prewired connection system and a Modbus network
More informationThe right solution for every home
Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building
More informationSurge & Filter Protection Addressing your industrial power quality needs.
Surge & Filter Protection Addressing your industrial power quality needs. BULLETIN 983 INTRODUCING SURGE & FILTER PROTECTION SURGE & FILTER PROTECTION Rockwell Automation is pleased to introduce the Bulletin
More informationOur Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium
Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Voltage Panels and Enclosures designed and built with
More informationHigh-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay
High-Tech Range IRI1-ES- Sensitive Earth Fault Current Relay IE ON RESET.5 X1 t IE X1.6%.2.4.8 1.6 X1.1s.2.4.8 1.6 X2 OFF ON S1 S2 IRI1-ES IRI1-ES C&S Electric Limited (Protection & Control Division) Contents
More informationIRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)
IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationSection 4 Ground-Fault Protection Devices
Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that
More informationReliable Switchgear from One Proven Supplier
Catalogue Industrial Switchgear 2007/2008 Reliable Switchgear from One Proven Supplier Xtra Combinations Xtra Combinations from Moeller offers a range of products and services, enabling the best possible
More informationCommunication COM option in Masterpact
CT CCM modbus CD CE Functions and characteristics Communication COM option in 056431 056401 The COM option is required for integration of the circuit breaker or switch-disconnector in a supervision system.
More informationBCM ULP Breaker Communication Module
DOCA0152EN-00 BCM ULP Breaker Communication Module Firmware Version 4.1.9 Release Note 05/2018 The information provided in this documentation contains general descriptions and/or technical characteristics
More informationDOC Electrical Installation Calculation and Dimensioning
Help ABB SACE A Division of ABB S.p.A., MK-TO, 2011 DOC Electrical Installation Calculation and Dimensioning February 14, 2011 Slide 1 Contents Use cases ABB Software Desktop February 14, 2011 Slide 2
More informationP Series PlexPower Distribution Panelboards Increased Safety
Applications The P Series PowerPlex panelboard provides indoor and outdoor protection and control of electrical circuits in hazardous environments such as: Petroleum plants Chemical plants Refineries Other
More informationKMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available
KMP A3 Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available High power switchgear systems For primary applications The name MediPower represents powerful medium voltage energy distribution
More informationB60 Domestic Voltage Optimisation Unit
B60 Domestic Voltage Optimisation Unit Installation Manual V1.2 Nov 2013 1 P a g e PRODUCT ADVISORY NOTICE This product must be installed by a competent person in accordance with the IEE Wiring Regulations,
More informationSafe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS
www.moeller.net Safe Isolation of Main Circuits with Switch-Disconnectors N or with Molded Case Switches NS Reliably and safely controlling, switching and managing power. In industry, in buildings and
More informationSolutions guide for commercial buildings, carports, and decentralised power plants. using Conext TL small three-phase PV inverters
Solutions guide for commercial buildings, carports, and decentralised power plants using Conext TL small three-phase PV inverters Schneider Electric, a bankable partner you can trust Table of contents
More informationMULTI 9 System Catalog
MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault
More informationBT300 HVAC Drives Electronic Bypass (E-Bypass) Options
BT300 HVAC Drives Electronic Bypass (E-Bypass) Options Description The BT300 Electronic Bypass (E-Bypass) Options are companion packages for the family of BT300 Variable Frequency Drives (VFDs). For information
More informationSentron 3VT circuit breakers Simply Smart: First choice for power distribution
s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case
More informationBuild electrical installations more efficiently. Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A
Build electrical installations more efficiently Prisma G Simple, functional systems for safe, upgradeable LV switchboards up to 630 A Develop your business efficiency wit Switchboards that are safe With
More information2 Principle of lightning protection
2 Principle of lightning protection The system for protecting a building against the effects of lightning must include: bprotection of structures against direct lightning strokes; bprotection of electrical
More informationREYROLLE 2RMLG. Operating Recommendations
2RMLG Operating Recommendations SAFETY The commissioning and maintenance of protection equipment should only be carried out by skilled personnel trained in protective relay operation and capable of observing
More informationHigh Safety low voltage switchgears For maximum requirements far beyond all standards.
High Safety low voltage switchgears For maximum requirements far beyond all standards. High Safety solutions From the specialist for arc fault protection For years, the names ModuPro and ModuCon have stood
More informationMMLG 01, 02, 03, 04 MMLB01
MMLG 01, 02, 03, 04 MMLB01 Technical Data Test Blocks and Test Plugs Publication Reference: MMLG_MMLB/EN/TD/B - ALSTOM 2015. All rights reserved. Information contained in this document is indicative only.
More informationSWITCH DISCONNECTORS 11
SWITCH DISCONNECTORS 16A to 1600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 850A 1000VDC in DC21B duty
More information