Table of Contents. 580 Electronics

Size: px
Start display at page:

Download "Table of Contents. 580 Electronics"

Transcription

1 Table of Contents Ancre 580 Electronics Features and Benefits 06 DeviceNet 07 Ethernet/IP TM 09 Profibus-DP PROFINET EtherNet/IP TM DLR 5 IO-Link Class A & B 7 EMERSON CHARM 9 Dimensional Drawing Fieldbus Communication Assembly - ATEX Certification (50/50) How to Order Assembly Kit & 580 Electronics How to Order Complete 580 Manifold Assemblies 5..6 How to Order - Sandwich shut off block 7 0GB-07/R0 Fielbus Electronics - 05

2 FIELDBUS ELECTRONICS 580 Electronics (Series 50-50: M7 to /8 (G or NPT) or with push-in fittings Ø to mm) Series Fieldbus - Electronics Made Easy! Innovative Graphic Display is used for easy commissioning, visual status & diagnostics Commissioning Capabilities Set network address (including IP & Subnet mask for Ethernet) Set baud rate Set factory defaults Visual Diagnostics Shorted and open load detection Shorted sensor/cable detection Low & missing power detection Self-tests activation Log of network errors Graphic Display for configuration & diagnostics 580 Fieldbus Communications Electronics Why use Numatics Fieldbus communication electronics? Modular Reality... No internal wiring simplifies assembly Power connector allows output power to be removed while inputs and communication are left active IP65 protection Compact Electronic Module Supported Protocols DeviceNet Ethernet/IP PROFIBUS -DP PROFINET EtherNET/IP DLR IO-Link (Class A & Class B) CHARMs DeviceNet TM is a trademark of ODVA. PROFIBUS and PROFINET are registered trademarks of Profibus International Fielbus Electronics 0GB-07/R0

3 DeviceNet DeviceNet is an open bus fieldbus communication system developed by Allen-Bradley based on Controller Area Network (CAN) technology. The governing body for DeviceNet is the Open DeviceNet Vendors Association (ODVA). The ODVA controls the DeviceNet specification and oversees product conformance testing. Numatics 580 nodes for DeviceNet have an integrated graphic display. They have been tested and approved for conformance by the ODVA. More information about DeviceNet and the ODVA can be obtained from the following WEB site: Description DeviceNet communications module (node) ATEX - (GD) IP65X - (GD) IP5X (G) IP5X HOW TO ORDER Consult the online configurator - CAD files on: DeviceNet 5 COMMUNICATION MALE Pin = Shield Pin = V+ ( V DC) Pin = V- (Ground) Pin = CAN_H Pin 5 = CAN_L POWER MALE Pin = + V DC (node) Pin = + V DC (Valves) Pin = 0 V DC (node) Pin = 0 V DC (Valves) Technical Data Electrical Data Voltage Current Node Power at Max. Brightness V DC +/- 0% 0,070 A BUS Power -5 V DC Valves V DC +/- 0% 8 A Maximum Power Connector Single key pin M (male) Communication Connector Single key 5 pin M (male) LED's Module Status and Network Status 0GB-07/R0 Operating Data Temperature Range (ambient) -0ºC to +50ºC Humidity 95% relative humidity, non-condensing Vibration / Shock IEC , IEC Moisture Protection IP65 Configuration Data Graphic Display Display used for setting Node Address, Baud Rate, Fault / Idle Actions, and all other system settings. Maximum Valve-Solenoid Outputs 8 (50) / (50) Network Data Supported Baud Rates 5K Baud, 50K Baud, 500K Baud, with Auto-Baud detection Supported Connection Type Polled, Cyclic, Change of State (COS) and combination Message Capability Bus Connector Single key 5 pin M (male) Diagnostics Power, short, open load conditions are monitored Special Features Supports Auto-Device Replacement (ADR) and fail-safe device settings Weight DeviceNet Communication Module 5 g Fielbus Electronics - 07

4 DeviceNet bus connection the front panel of the communication module for DeviceNet is equipped with a 5 pin 7/8-6 UN male socket (E). The bus can be connected in the two following ways: directly to the module with a T-connector; with a straight connector, cable (max. length: m) and a DeviceNet distributor box. The modules on either side of the system must be provided with terminating resistors (L or L). Wiring with T-connector Connection with DeviceNet distributor box (X) K G F H K K K m max. L E K J G E BUS V DC power supply Accessories for DeviceNet The modules on either side of the system must be provided with terminating resistors H Accessory Description Order Code G M 90 5 Pin Female Field Wireable network Connector Spring Cage (A coded) PG9 cable gland M Straight 5 Pin Female Field Wireable network Connector Spring Cage PG9 cable gland TD05F V TC05F V H M Straight 5 Pin Male Field Wireable network Connector Spring Cage PG9 cable gland TA05F V F Way M T (T-connector M, 5 male / female / female pins) TC TT05000 L J (K) Cable to be ordered separately. Terminating resistor male plug TA05TR Terminating resistor female plug M 90 Pin Female Field Wireable Connector (PG 9 Cable Gland) ( pin elbow female cable connector 7/8 ) - V DC power supply M 90 Pin Female Single Ended Cable, Euro Color Code ( pin elbow female cable connector 90 with 0 m cable) V DC power supply BN (brown) WH (white) BU (blue) BK (black) TD0F TD00MAE GB-07/R Fielbus Electronics

5 Ethernet/IP TM Ethernet TM used throughout the world to network millions of PC s has now evolved into a viable industrial network. Ethernet TM is an open architecture high-level communication network that meets the demands of today s industrial applications requiring highspeed (0/00 Mbit/s), high-throughput and flexibility. Additionally, Ethernet TM technology can integrate an on-board Web server, which can make the node readily accessible for configuration, testing and even retrieval of technical documentation. Numatics 580 nodes for Ethernet TM have an integrated graphic display. The 580 Ethernet/IP TM nodes have been tested and approved for conformance by the ODVA. More information about Ethernet/IP TM and the ODVA can be obtained from the following WEB site: www. odva.org Description Ethernet/IP TM communications module (node) ATEX - (GD) IP65X - (GD) IP5X (G) IP5X HOW TO ORDER Consult the online configurator - CAD files on: Ethernet/IP Technical Data COMMUNICATION FEMALE Pin = TX+ Pin = RX+ Pin = TX- Pin = RX- POWER MALE Pin = + V DC (node) Pin = + V DC (Valves) Pin = 0 V DC (node) Pin = 0 V DC (Valves) Electrical Data Voltage Current Node Power at Max. Brightness VDC +/- 0% 0,09 A Valves VDC +/- 0% 8 A maximum Power Connector Single key pin M (male) Communication Connector D-coded 5 pin M (female) LED's Module Status, Network Status and Activity/Link 0GB-07/R0 Operating Data Temperature Range (ambient) -0ºC to +50ºC Humidity 95% relative humidity, non-condensing Vibration / Shock IEC , IEC Moisture Protection IP65 Configuration Data Graphic Display Display used for setting Subnet mask, Fault / Idle Actions, DHCP / BootP and all other system settings. Maximum Valve-Solenoid Outputs 8 (50) / (50) Network Data Supported Baud Rates 0 Mbit / 00 Mbit Bus Connector D-coded 5 pin M (female) Diagnostics Power, short, open load conditions and module health are monitored Special Features Integrated web server, fail-safe device settings, HTTP, FTP, and UNICAST (for EtherNet/IP) Weight Ethernet Communication Module 6 g Fielbus Electronics - 09

6 Accessories for EtherNet/IP Accessory Description Order Code M Straight Pin Male D-Coded to Male RJ5 network Cable - Shielded 5 m QA005MK0VA m QA00MK0VA0000 M elbow Pin Male D-Coded Field Wireable network Connector PG 9 Cable Gland Screw Terminal QB0F N M 90 Pin Female Field Wireable Connector (PG 9 Cable Gland) ( pin elbow female cable connector 7/8 ) - V DC power supply TD0F M 90 Pin Female Single Ended Cable, Euro Color Code ( pin elbow female cable connector 90 with 0 m cable) V DC power supply BN (brown) WH (white) BU (blue) BK (black) TD00MAE GB-07/R0 0 - Fielbus Electronics

7 PROFIBUS-DP PROFIBUS-DP is a vendor-independent, open fieldbus protocol designed for communication between automation control systems and distributed I/O at the device level. Numatics 580 nodes for PROFIBUS-DP have an integrated graphic display. The 580 nodes for PROFIBUS-DP have been designed and tested to conform to the PROFIBUS standard EN5070. Certification has been done by the PROFIBUS Interface Center (PIC) according to the guidelines determined by the PROFIBUS Trade Organization (PTO). The Description certification process ensures interoperability for all PROFIBUS devices. More information regarding PROFIBUS can be obtained from the following WEB site: PROFIBUS-DP communications module DPV0/DPV ATEX - (GD) IP65X - (GD) IP5X (G) IP5X HOW TO ORDER Consult the online configurator - CAD files on: 5 PROFIBUS-DP 5 Technical Data COMMUNICATION FEMALE OUT Pin = +5V DC Pin = RxD/TxD-N / Data Line A Pin = DATA GROUND (0V DC) Pin = RxD/TxD-P / Data Line B Pin 5 = No Connected Thread = Shield COMMUNICATION MALE IN Pin = No Connected Pin = RxD/TxD-N / Data Line A Pin = No Connected Pin = RxD/TxD-P / Data Line B Pin 5 = No Connected Thread = Shield 5 POWER MALE Pin = + V DC (node) Pin = 0 V DC (Valves) Pin = 0 V DC (node) Pin = + V DC (Valves) Pin 5 = Earth Ground Electrical Data Voltage Current Node Power at Max. Brightness VDC +/- 0% 0,09 A Valves VDC +/- 0% A Maximum Power Connector Single key 5 pin M (male) Communication Connector Single reverse key (B-Coded) 5 pin M ( male and female) LED's Module Status and Network Status 0GB-07/R0 Operating Data Temperature Range (ambient) -0ºC to +50ºC Humidity 95% relative humidity, non-condensing Vibration / Shock IEC , IEC Moisture Protection IP65 Configuration Data Graphic Display Display used for setting Node Address, Baud Rate, Fault / Idle Actions, Diagnostics and all other system settings. Maximum Valve-Solenoid Outputs 8 (50) / (50) Network Data Supported Baud Rates Auto-Baud Bus Connector Single reverse key (B-coded) 5 pin M ( male and female) Diagnostics Power, short, open load conditions and module health are monitored Special Features Supports Auto-Device Replacement (ADR) and fail-safe device settings Weight PROFIBUS-DP Communication Module g Fielbus Electronics -

8 PROFIBUS-DP bus connection The front panel of the communication module for Profibus-DP is equipped with: - a 5 pin male 7/8 socket for power supply - a 5 pin male M-B socket or 5 pin female M-A socket for the bus cable (with a T-connector on integrated M COM-IN/ COM-OUT connector) Fieldbus connection Wiring with T-connector K FIELDBUS ELECTRONICS - SERIES 580 L H F J G K BUS V DC power supply Accessories for PROFIBUS-DP The modules on either side of the system must be provided with terminating resistors H Accessory Description Order Code F T-connector M-B, 5 female / male / male pins (Profibus Mb max) G M-B network connector, 5 female pins - for cable dia. 6-8 mm (Profibus Mb max) M 90 5 Pin Male & Female Field Wireable network Connectors, w/idc PG9 Cable Gland IDC FEMALE RD05F00P00007V M-B network connector, 5 male pins - for cable dia. 6-8 mm (Profibus Mb max) L M 90 5 Pin Male & Female Field Wireable network Connectors, w/idc PG9 Cable Gland IDC MALE RB05F00P00007V H Terminating resistor M-B - male plug J (K) Cable to be ordered separately. - Fielbus Electronics M 90 5 Pin Female Field Wireable Connector ( V DC supply, PG 9 Cable Gland) M 90 5 Pin Female Single Ended Cable, Euro Color Code (5 pin elbow female cable connector, V DC supply, with 0 m cable) 5 5 BN (brown) WH (white) BK (black) BU (blue) GN/YE (green/yellow) TD05F TD050MAE Dust cover - M female GB-07/R0

9 PROFINET PROFINET is the innovative open standard for Industrial Ethernet, development by Siemens and the Profibus User Organization (PNO). PROFINET complies to IEC 658 and IEC 678 standards. PROFINET products are certified by the PNO user organization, guaranteeing worldwide compatibility. Numatics 580 nodes for PROFINET IO (PROFINET RT) have an integrated graphic display. PROFINET is based on Ethernet and uses TCP/IP and IT standards and complements them with specific protocols and mechanisms to achieve Real Time performance. Additionally, the 580 node PROFINET can integrate an on-board Web server, which can make the node readily accessible for configuration, testing and even retrieval of technical documentation. More information regarding PROFINET can be obtained from the following WEB site: Remark: Compatibility with MRP functionnalities. Description PROFINET communications module (node) FIELDBUS ELECTRONICS - SERIES 580 ATEX COMMUNICATION FEMALE Pin = TD+ Pin = RD+ Pin = TD- Pin = RD- - (GD) IP65X - (GD) IP5X (G) IP5X HOW TO ORDER Consult the online configurator - CAD files on: PROFINET POWER MALE Pin = + V DC (node) Pin = 0 V DC (Valves) Pin = 0 V DC (node) Pin = + V DC (Valves) Pin 5 = Earth Ground 5 Technical Data COMMUNICATION FEMALE Pin = TD+ Pin = RD+ Pin = TD- Pin = RD- Electrical Data Voltage Current Node Power at Max. Brightness VDC +/- 0% Valves VDC +/- 0% A Maximum Power Connector Single key 5 pin M (male) Communication Connector Two D-coded pin M (female) LED's Module Status, Network Status and Activity/Link 0GB-07/R0 Operating Data Temperature Range (ambient) -0ºC to +50ºC Humidity 95% relative humidity, non-condensing Vibration / Shock IEC , IEC Moisture Protection IP65 Configuration Data Graphic Display Display used for setting IP Address, Subnet Mask, Fault / Idle Actions, Diagnostics and all other system settings. Maximum Valve-Solenoid Outputs 8 (50) / (50) Network Data Supported Baud Rates 0 Mbit / 00 Mbit Bus Connector Two D-coded pin M (-Female) Diagnostics Power, short, open load conditions and module health and configuration are monitored Special Features Integrated web server, Integrated port switch, fail-safe device settings Weight PROFINET Communication Module g Fielbus Electronics -

10 Accessories for PROFINET Accessory Description Order Code 5 m QA005MK0VA0000 M Straight Pin Male D-Coded to Male RJ5 network Cable - Shielded 0 m QA00MK0VA0000 M elbow Pin Male D-Coded Field Wireable network Connector PG 9 Cable Gland Screw Terminal QB0F N M 90 5 Pin Female Field Wireable Connector ( V DC supply, PG 9 Cable Gland) TD05F M 90 5 Pin Female Single Ended Cable, Euro Color Code (5 pin elbow female cable connector, V DC supply, with 0 m cable) BN (brown) WH (white) BK (black) TD050MAE BU (blue) 5 GN/YE (green/yellow) - Fielbus Electronics 0GB-07/R0

11 EtherNet/IP TM DLR EtherNet/IP TM used throughout the world to network millions of PC s has now evolved into a viable industry network. EtherNet/ IP is an open architecture high-level communication network that meets the demands of today s industrial applications requiring high-speed (0/00 Mbit/s), high-throughput and flexibility. Additionally, EtherNet/IP TM technology can integrate an on-board Web server, which can make the node readily accessible to any standard Web browser for configuration, testing and even retrieval of technical documentation. Numatics 580 EtherNet/IP TM DLR (Device Level Ring) node with integrated display, has an embedded switch which allows the unit to be used in simplified networks with linear topology configurations (daisy chain). Additionally, the DLR compatibility allows the node to be used in a fault tolerant ring network, when using appropriate EtherNet/IP TM DLR scanners. DLR configuration allows communication Description recovery from a single point failure on the network ring (e.g. failed network connection or cable). The 580 EtherNet/IP TM nodes have been tested and approved for conformance by the ODVA More information about EtherNet TM and the ODVA can be obtained from the following WEB site: Open Device Vendors Association (ODVA) EtherNet/IP TM DLR communications module (node) ATEX - (GD) IP65X - (GD) IP5X (G) IP5X HOW TO ORDER Consult the online configurator - CAD files on: Ethernet/IP DLR COMMUNICATION FEMALE Pin = TX+ Pin = RX+ Pin = TX- Pin = RX- POWER MALE Pin = + V DC (node) Pin = + V DC (Valves) Pin = 0 V DC (node) Pin = 0 V DC (Valves) Technical Data Electrical Data Voltage Current Node Power at Max. Brightness Valves Power Connector Communication Connector LED's VDC +/- 0% A Maximum Single key pin M (male) Two D-coded pin M (female) Module Status, Network Status and Activity / Link 0GB-07/R0 Operating Data Temperature Range Humidity -0ºC to +50ºC 95% relative humidity, non-condensing Vibration / Shock IEC , IEC Moisture Configuration Data Graphic Display IP65 Certified Maximum Valve Solenoid Outputs 8 (50) / (50) Network Data Supported Baud Rates Bus Connector Diagnostics Special Features Weight EtherCAT communications module Display used for setting IP address, Subnet Mask, Fault / Idle Actions, Diagnostics and all other system settings. 0 Mbit / 00 Mbit Two D-coded pin M (female) Power, short, open load conditions and module health and configuration are monitored Embedded two port switch, Device Level Ring (DLR) compatibility, fail-safe device settings, integrated web server, HTTP, TFTP, UNICAST g Fielbus Electronics - 5

12 Accessories for EtherNET/IP TM DLR Accessory Description Order Code M Straight Pin Male D-Coded to Male RJ5 network Cable - Shielded 5 m QA005MK0VA m QA00MK0VA0000 M elbow Pin Male D-Coded Field Wireable network Connector PG 9 Cable Gland Screw Terminal QB0F N M 90 Pin Female Field Wireable Connector (PG 9 Cable Gland) ( pin elbow female cable connector 7/8 ) - V DC power supply TD0F M 90 Pin Female Single Ended Cable, Euro Color Code ( pin elbow female cable connector 90 with 0 m cable) V DC power supply BN (brown) WH (white) BU (blue) BK (black) TD00MAE GB-07/R0 6 - Fielbus Electronics

13 IO-Link (Class A & Class B) IO-Link is a globally standardized IO technology (IEC 6-9) developed primarily for communication with smart sensors and actuators that can also be used with valves and other field devices. IO-Link is used to individually link field devices and resides below the I/O level. An IO-Link Master with a higher level fieldbus or Ethernet communication protocol is required. The IO-Link Consortium, which is a technical committee within PROFIBUS & PROFINET International (PI), oversees and manages IO-Link specifications. Numatics IO-Link communications node offers both event based as well as standard I/O mapped diagnostics, requires minimal commissioning, and is compatible with distributed modular I/O. Supports both Class A ( pin) and Class B (5 pin) with isolated ground) communication port types. More information regarding IO-Link can be obtained from the following website: Description IO-Link Class A ( pin) Communications Module (node) IO-Link Class B (5 pin) Communications Module (node) ATEX - (GD) IP65X - (GD) IP5X (G) IP5X - (GD) IP65X - (GD) IP5X (G) IP5X HOW TO ORDER Consult the online configurator - CAD files on: Technical Data IO-Link (Class A & Class B) The IO-Link (Port Type A) The IO-Link (Port Type B) connector is a single keyway pin connector is a single keyway 5 pin M male connector 5 M male connector Pin = + V DC PWR Pin = + V DC PWR Pin = + V DC (Valves) Pin = + V DC (Valves) Pin = 0 V DC PWR (Valves) Pin = 0 V DC PWR Pin = IO-Link COMM (C/Q) Pin = IO-Link COMM (C/Q) Pin 5 = NO CONNECT Pin 5 = 0 V DC (Valves) 5 Node Power VDC +/- 0% 0,00 A Valves VDC +/- 0% A Maximum Power and Communication Connector Class A: A-Coded pin M (male)/class B: A-Coded 5 pin M with isolated ground (male) LEDs Valve Power, Node Power, Communication Temperature Range (ambient) -0ºC to 50ºC Humidity 95% Relative Humidity, Non-condensing Vibration/Shock IEC , IEC Moisture IP65 Certified 09GB-07/R0 Maximum Valve Solenoid Outputs 8 (50) / (50) Supported Baud Rates COM : 8,K Diagnostics Special Features IO-Link Communications Module IO Link field wireable Power, short, open load conditions with both standard I/O mapped diagnostics and event based diagnostics Fail-safe device settings Class A: 98 g, Class B: 0 g M straight 5 pins Female A-Coded IO Link field wireable PG-9 Cable Gland TC05F M 90 Elbow 5 pins Female A-Coded IO Link field wireable PG-9 Cable Gland TD05F Fielbus Electronics - 7

14 Accessories for IO-Link (Class A & Class B) Accessory Description Order Code M Class A Compatible Cables M Straight Pin Male Single Ended Cable, Euro Color Code,5 m TA0E5MIE00007P 5 m TA005MIE00007P M 90 Pin Male Single Ended Cable, Euro Color Code,5 m TB0E5MIE00007P 5 m TB005MIE00007P M Straight Pin Male to Female Cable Extension,5 m TC0E5MIETA07P m TC00MIETA07P M Class B Compatible Cables 5 m TC0505MIE00007P M Straight 5 Pin Female Single Ended Cable - Unshielded 0 m TC050MIE00007P 5 m TC0505MIETA057P M Straight 5 Pin Female to Male Double Ended Cable - Unshielded 0 m TC050MIETA057P 5 m TD0505MIE00007P M 90 5 Pin Female Single Ended Cable - Unshielded 0 m TD050MIE00007P Molded Body/Insert TPU Polyamide Coupling Nut Nickel Plated Zinc Nickel Plated Zinc Cable Jacket Material PUR NA Cable O.D. 5mm Accepts 6,5 mm Voltage Rating 60 V 5 V Current Rating A A Degree of Protection IP65 (mated) IP65 (mated) Operating Temperature -5 C to 90 C -0 C to 00 C Conductor Gauge AWG 8 AWG Minimum Bend Radius 50 mm NA Wire Connection NA Screw Terminal 8 - Fielbus Electronics Female View 09GB-07/R0

15 580 CHARM Node The 580 CHARM node allows the pneumatic valve manifold to directly connect to the CHARM I/O Card (CIOC) baseplate and be controlled by DeltaV. The 580 CHARM node is connected via cables to the bottom baseplate extender of the (CIOC). This provides full redundancy to the pneumatic manifold. The 580 CHARM node is commissioned via the DeltaV explorer. Description 580 CHARM module (node) ATEX - (GD) IP65X - (GD) IP5X HOW TO ORDER Consult the online configurator - CAD files on: (G) IP5X CHARM 5 Technical Data Electrical Data Voltage Current Comm. Power (via baseplate extender) 6, V 00 ma Valve Power (via baseplate extender) V,07 A Power and Communication Connector LED's A-coded 5 Pin M (male) Module Status and Network Status COMMUNICATION MALE Pin = Shield Pin = V+ ( V DC) Pin = V- (Ground) Pin = CAN_H Pin 5 = CAN_L 09GB-07/R0 Operating Data Temperature Range (ambient) Humidity Vibration / Shock Moisture Protection Configuration Data Graphic Display -0ºC to +50ºC 95% relative humidity, non-condensing IEC , IEC IP65 Maximum Valve-Solenoid Outputs 8 (50 Series) / (série 50) Network Data Redundant Power and Comm. Connectors (Primary & Secondary) Diagnostics DeltaV version Weight CHARM Communication Node Display used for setting CHARM address and all other system settings. A-coded 5 Pin M (male) Power, short, open load conditions are monitored Compatible DeltaV series S ; FHX file integrated in v version ; download file for v and v versions 6 g Fielbus Electronics - 9

16 CHARM Communication & Power connection the front panel of the communication module is equipped with a 5 pin M. Address Plug CHARM Baseplate Address Plug CHARM Baseplate Primary Comm. & Power Secondary Comm. & Power Address Plug Address Plug CHARM Baseplate CHARM Baseplate Both Cables provide 6. V for Comm. and V for valve Power Accessories for CHARM Accessory Description Order Code - Cables with M and sub-d plug (,5 m) P599AF ,5 Meter Cable with M and Sub-D Connectors (Moulded version) P599AF ,5 Meter Cable with M and Sub-D Connectors (Moulded version) P599AF Valve Power Isolator M-Y P599AF Fielbus Electronics 09GB-07/R0

17 Dimensions (mm) Dimensional Drawing Fieldbus Manifold Assembly 50 Series Valve Manifold Assembly with 580 Electronics Configurator - CAD Files,5 97 (8,5 x ) [ 6 subbases],8 9, 97, , 7, 76,6 M7 x /8 Ø5,5 mm Ø5,5 mm WARNING : DO NOT CONNECT OR DISCONNECT PLUGS AND SOCKETS WHEN ENERGIZED WARNING : POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS 8, 0GB-07/R0 * - For valve manifold dimensions refer to Valve Series product catalogs Fielbus Electronics -

18 Dimensions (mm/ Inches) Dimensional Drawing Fieldbus Manifold Assembly 50 Series Valve Manifold Assembly with 580 Electronics P [ 6 subbases] Q R /8 x /8 N K J M L H x Ø5,5 mm A C - Fielbus Electronics WARNING : POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS A C E F G H J K L M N P Q R ,95, 75,8 6 07, 9,5 87,8 9, 68,, * - For valve manifold dimensions refer to Valve Series product catalogs E WARNING : DO NOT CONNECT OR DISCONNECT PLUGS AND SOCKETS WHEN ENERGIZED F G 0GB-07/R0

19 ATEX CERTIFICATION ATEX Directive Apparatus suitable for use in ATEX Group II, Category, gas (G) or dust (D) environments Temperature class: T (gas), T85 C (dusts) Ingress protection: IP65 / IP5 Ambient temperature range: -0 C Ta +50 C (50/50) Marking: Gas and dusts: II G Ex na IIC T Gc IP5 X or IP65 X II D Ex tc IIIA or IIIB T85 C Dc IP5 X or Ex tc IIIC T85 C Dc IP65 X Dusts: II G Ex na IIC T Gc IP5 X SPECIAL CONDITIONS FOR SAFE USE The apparatus must be installed in a control cabinet with a protection degree of IP5 or IP65 in conformance with standards EN and EN (and EN for dust applications). WARNING LIVE PARTS: DO NOT DISCONNECT CONNECTORS FROM SOCKETS WHILE POWER IS ON The cross-section of the ground cable must be equal to the minimum cross-section of the supply cable. Provide for equipotential bonding between the apparatus and the control cabinet. Electrical connections must be made by qualified personnel to ensure reliable operation. The contact pressure of electrical connections must be maintained during regular operation. WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS Precautions shall be taken to guard against any effect due to the presence of circulating current caused by stray magnetic fields. Avoid all static charge build-up on the apparatus. No air movement inside the cabinet max. coils () max. coils () charms 8 () Do not exceed the max. number of pilot solenoid valves authorised. The internal temperature of the cabinet may not exceed the minimum and maximum tempreatures specified on the product. Do not disassemble any component of the device except when replacing spare parts. The specifications of IP5 or IP65 must be met when installing the device in the cabinet. ASSEMBLY IN ATEX Ex e COMPLIANT CONTROL CABINET 0GB-07/R0 Fieldbus V DC power supply 580 Series Pressure supply Output to actuators Fielbus Electronics -

20 50-50 How to Order Manifold assemblies kit (Electronic + End plate) 5-DIGIT PRODUCT CODE G 50 A V 8 B 0 0 V A6 Thread connection ATEX options G = ISO 8/ 8 = NPT (contact us) - (GD) IP65X - (GD) IP5X (G) IP5X K = Push-in connectors A6 = A00 () A = A00 () A = A00 () D6 = DRM () D = DRM () D = DRM () D8 = X () D = X () D = X () F6 = D () F8 = D () F9 = D () () Standard (no options) Product series () DIN Rail Mount 50 ( mm valve) () External pilot supply from port 50 (8 mm valve) () External pilot supply from port and DIN Rail Mount Revision letter A = Initial release Product type V = Valve Manifold Assembly Electronics End Plate Style V = Vertical 8 = 580 Fieldbus Electronics End Plate Port Size (--5) D = CHARMs Electronics 50: Used with the first digit «G» or «8»: = /8 (female thread only) Used with the first digit «K»: H = 6 x 8 mm (push-in connector) Number of Valve Stations 50: Used with the first digit «G» or «8» or «K»: B = L = V = * 7 = * A = NA/* H = 8/0* O = 5/7* V = * = 9* = /8 D = N = * X = * B = NA/* I = 9/* P = 6/8* W = * 5 = 0* (female thread or push-in connector) F = 6 P = 6* Z = 6* C = /5* J = 0/* Q = 7 X = * 6 = * Used with the first digit «K»: H = 8 R = 8* = 8* D = /6* K = /* R = 8 Y = 5* 7 = * K = 8 x 0 mm (push-in connector) J = 0 T = 0* 5 = 0* E = NA/7* L = /* S = 9* Z = 6* M = 0 x mm (push-in connector) F = 6/8* M = /5* T = 0* = 7* G = 7/9* N = /6* U = * = 8* 580 ATEX max. coils () CHARMs () Max. number of coil under voltage Fielbus Electronics * 580 CHARMs only. How to Order 580 Electronics 5-DIGIT PRODUCT CODE P 580 A E DN 0 0 7W Product series ATEX options 580 Fieldbus Electronics 7W = Standard (no options) Revision letter Connector Type A = Initial release = M Connector (push-in connector) Actuation Protocol E = Electronics DN = DeviceNet LM = IO-Link Class A ( pin) ED = EtherNet/IP DLR LM = IO-Link Class B (5 pin) EP = EtherNet/IP PN = PROFINET 50 PT = PROFIBUS-DP CH = CHARMs 50 0GB-07/R0

21 50 Thread connection R = Pad mount How to Order Valves 5-DIGIT PRODUCT CODE R 50 A B 0 M 7W F Configurator - CAD Files Voltage - class F = V DC - class F 50 Product series ATEX options 50 ( mm valve) 7W = With impulse manual operator 8L = With maintained manual operator 8A = Without manual operator Revision letter A = Initial release Actuation Electrical interface = Rubber packed M = Plug-in (with LED indicator / DC) Valve type B = Solenoid pilot Function A = x/ NO, dual -way D = x/ NC, dual -way N = 5/, Differential air return = 5/, spring return = 5/, solenoid air return 5 = 5/, W, open center to exhaust 6 = 5/, W, center closed 7 = 5/, W, open center to pressure 50 Thread connection R = Pad mount 5-DIGIT PRODUCT CODE R 50 A B 0 M 7W F Voltage - class F = V DC - class F 50 Product series ATEX options 50 (8 mm valve) 7W = With impulse manual operator () 8L = With maintained manual operator 8A = Without manual operator 0GB-07/R0 Revision letter A = Initial release Actuation = Rubber packed Valve type B = Solenoid pilot (With impulse manual operator) Function D = x/ NC, dual -way Electrical interface M = Plug-in (with LED indicator / DC) () Used external spool valves (internal/external supply configurated in the end plate kits). For internal piloting, contact us. Fielbus Electronics - 5

22 50 Thread connection H = Metric thread K = Push-in connectors How to Order Subbase 5-DIGIT PRODUCT CODE H 50 A M S B M 7W 0 Not use Interface = High flow 50 Product series ATEX options 50 ( mm valve) 7W = Standard (zone or zones -) Revision letter A = Initial release Product type M = Manifold base Z = Mid station supply F = + Solenoid Manifold Subbase Wiring option M = Plug-in Mounting S = Manifold base, stations, side port, single Z-Board M = Manifold base, stations, side port, double Z-Board Port connection B = M7 (female thread only) D =,7 x mm (5/) [push-in connector only] (Mid station supply not available) F = x 6 mm [push-in connector only] 50 5-DIGIT PRODUCT CODE G 50 A M M M 7W 0 Thread connection Not use G = ISO 8/ 8 = NPT (contact us) Interface K = Push-in connectors = Pneumatic high flow = ISO 507- (8 mm) 50 Product series ATEX options 50 (8 mm valve) 7W = Standard (zone or zones -) Revision letter A = Initial release Product type M = Manifold base Z = Mid station supply 6 - Fielbus Electronics Wiring option M = Plug-in Mounting Port connection (-) S = Manifold base, stations, side port, single Z-Board Used with the first digit «G» or «8»: M = Manifold base, stations, side port, double Z-Board = /8 (female thread only) Used with the first digit «K»: F = 6 x 8 mm [push-in connector only] H = 8 x 0 mm [push-in connector only] 0GB-07/R0

23 Sandwich shut off block (50-50 Series) Used to shut-off pressure to the valve which is mounted above it. Allows easy maintenance without the need to shut-off pressure to the whole manifold. (specified for x/ NC-NC valve) 50 Series ()()()() () (5)() 50 Series EB B P A XE () () () () EA (5) X ()()()() () (5)() XE () () EB B () P () A (5) X EA 6,5 D C 9,5,5 B 09, A! Usable only for internal pilot supply island! Pay attention to residual pressures! The valve(s) should not be energised during disassembly weight (kg) 50 0, 50 0,5 Dimensions (mm) A B C D 50 7, 50,5 7,5 8,5 0GB-07/R0 5-DIGIT PRODUCT CODE R50AY85000 Description Sandwich shut off block (double) HOW TO ORDER [ATEX options (zone or zones -)] Consult the online configurator - CAD files on: 5-DIGIT PRODUCT CODE 50 R50AY90900 Description High Flow - Sandwich shut off block Fielbus Electronics - 7

24 8 - Fielbus Electronics 0GB-07/R0

G3 displays its innovations!

G3 displays its innovations! G3 displays its innovations! ATEX Innovative Graphic Display is used for easy commissioning, visual status & diagnostics Commissioning Capabilities Set network address Set baud rate Set auto or manual

More information

501 Series Solenoid Pilot Actuated Valves

501 Series Solenoid Pilot Actuated Valves 501 Series Solenoid Pilot Actuated Valves www.numatics.com Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Our broad spectrum of standard, custom developed products

More information

501 Series Solenoid Pilot Actuated Valves

501 Series Solenoid Pilot Actuated Valves 501 Series Solenoid Pilot Actuated Valves www.numatics.com Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Our broad spectrum of standard, custom developed products

More information

G3 Electronic displays its innovations! Innovative Graphic Display is used for easy commissioning, visual status & diagnostics. ATEX G3 Electronics

G3 Electronic displays its innovations! Innovative Graphic Display is used for easy commissioning, visual status & diagnostics. ATEX G3 Electronics Features p1 ATEX G3 Electronic displays its innovations! Innovative Graphic Display is used for easy commissioning, visual status & diagnostics Commissioning Capatibilities Set network address Set baud

More information

G3 Series DeviceNet TM Technical Manual

G3 Series DeviceNet TM Technical Manual G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined

More information

503 Series Solenoid Pilot Actuated Valves

503 Series Solenoid Pilot Actuated Valves 503 Series Solenoid Pilot Actuated Valves www.numatics.com Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Our broad spectrum of standard, custom developed products

More information

Fieldbus Electronics. G3 Communication Node and I/O 580 Communication Node.

Fieldbus Electronics. G3 Communication Node and I/O 580 Communication Node. Fieldbus Electronics G Communication Node and I/O 0 Communication Node www.asco.com Table of Contents G Electronics Features and Benefits 2 G Platform Distribution Options 4 CANopen 6 CC-Link IE Field

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

Solenoid Pilot Actuated Valves

Solenoid Pilot Actuated Valves Solenoid Pilot Actuated Valves 503 Series Zoned Safety Manifold www.asco.com Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Our broad spectrum of standard,

More information

MPCR Series DeviceNet Technical Manual

MPCR Series DeviceNet Technical Manual MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as

More information

Table of Contents. Fieldbus Electronics and I/O G2-1 Electronics G2-2 Electronics Individual Base Node...

Table of Contents. Fieldbus Electronics and I/O G2-1 Electronics G2-2 Electronics Individual Base Node... Table of Contents Fieldbus Electronics and I/O............................... - G- Electronics..................................................................... - Features and Benefits..................................................................................

More information

2002 Series DeviceNet Technical Manual

2002 Series DeviceNet Technical Manual 2002 Series DeviceNet Technical Manual Table of Contents 2002 Series DeviceNet Technical Manual 2002 Introduction...4 Product Overview...4 About DeviceNet...5 Overview...5 2002 DeviceNet Features...5 Cabling

More information

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. I P MAC AD D RE S S Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with an integrated Numatics G2-2 Series EtherNet/IP communication node. 1)

More information

2005/2012 Series Profibus DP Technical Manual

2005/2012 Series Profibus DP Technical Manual 2005/2012 Series Profibus DP Technical Manual LT2005/2012PBTECH-1 04/02 www.numatics.com Table of Contents 2005/2012 Series Profibus DP Technical Manual PAGE About Profibus DP... 3 Overview... 3 G2-2 Profibus-DP

More information

G3 Series EtherNet/IP TM Technical Manual

G3 Series EtherNet/IP TM Technical Manual G3 Series EtherNet/IP TM Technical Manual Conditions for use of this product G3 Series EtherNet/IP Technical Manual () Numatics G3 Manifold ("the PRODUCT") shall be used in conditions; i) Where any problem,

More information

MPCR Series Profibus-DP Technical Manual

MPCR Series Profibus-DP Technical Manual MPCR Series Profibus-DP Technical Manual TDMPCRPBTECH-1 12/04 www.numatics.com Table of Contents MPCR Series Introduction...3 Product Overview...3 About Profibus...4 Overview...4 MPCR Profibus Features...4

More information

Table of Contents. Individual Base Node Direct to PLC Cables and Accessories

Table of Contents. Individual Base Node Direct to PLC Cables and Accessories Table of Contents Fieldbus Electronics and I/O...- G- Electronics....- Features and Benefits... Communication Protocols...-8 How to Order.... AKC Communication Module... 0 LH Mounting Cover Kit... 0 Fieldbus

More information

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language)

XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) XPSMCMx Fieldbus Expansion Modules EAV8283001 12/2014 XPSMCMx Fieldbus Expansion Modules Instruction Sheet (Original Language) 12/2014 EAV8283001.00 www.schneider-electric.com The information provided

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

Fieldbus Gateway Type ME43

Fieldbus Gateway Type ME43 Fieldbus Gateway Type ME43 Gateway for Industrial Ethernet and Fieldbus standards Up to 128 input and 128 output variables can be assigned Easy integration in the process control system ensured through

More information

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth. D460/D470 Series - ATEX certified position transmitter nnnn II 2 GD ITS 11 ATEX 17431X Ex d IIC T* Gb Tamb -*ºC to +*ºC Ex tb IIIC T* Db Tamb -*ºC to +*ºC IP6X Ambient variation -60 C to +110 C (T4/T130

More information

2005 / 2012 / 2035 Series

2005 / 2012 / 2035 Series Generail Information on Fieldbus Systems FEATURES Solenoid air operated valve manifolds for date exchange via fieldbus. Internal wiring by Z-Board plug-in system. Plug-together flexibility due to different

More information

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4

RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804 Digital Input Module with Time Stamp EP-12F4 GFK-2975C August 2016 Module Status LED Channel Status LEDs Digital Input Connector Ground 24 V DC FE Digital Input Module RSTI-EP Slice I/O Digital Input Modules EP-1214, EP-1218, EP-1318, EP-125F, EP-1804

More information

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.

Dual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed. 2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

G3 Series PROFIBUS DP Technical Manual

G3 Series PROFIBUS DP Technical Manual G3 Series PROFIBUS DP Technical Manual Table of Contents G3 Series PROFIBUS DP Technical Manual PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined

More information

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

FACTORY AUTOMATION QUICK START GUIDE IC-KP-* FACTORY AUTOMATION QUICK START GUIDE IC-KP-* IDENTControl units With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products

More information

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s

Electropneumatic miniature control valves Mounting Connectors Minisolenoid valves Indicators LED seals LED Valve modules Poppet 3/2 single pilot 4/2 s ElectroPneumatic Miniature Control Valves Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com /47 Electropneumatic miniature control valves Mounting Connectors Minisolenoid

More information

MGate 5111 Quick Installation Guide

MGate 5111 Quick Installation Guide MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 50 mm flush -wire DC S Technical Data specifications Switching function Normally open (NO) Output type PNP Rated operating distance s n 50 mm Installation flush Output polarity DC

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

MGate 5105-MB-EIP Quick Installation Guide

MGate 5105-MB-EIP Quick Installation Guide MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm

Fieldbus System. New. New. Series EX260 IP67. Drives up to 32 solenoids. Daisy-chain wiring communication. Compact 28mm Fieldbus System (Output device for driving port solenoid valves) Compact 8mm (Actual size) Space-saving Installation Daisy-chain wiring communication New IP67 For units with D-sub connector, and when connected

More information

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Digital electropneumatic Positioner for the integrated mounting on process

Digital electropneumatic Positioner for the integrated mounting on process Digital electropneumatic Positioner for the integrated mounting on process control valves Compact, robust stainless Steel design Easy start-up by automatic X-Tune function Contact-free position sensor

More information

Multipole and Fieldbus

Multipole and Fieldbus > Series 3 Plug-In valve islands Valve Islands > 016 Series 3 Plug-In valve islands, Multipole and Fieldbus New versions Plug-In system for Series 3 solenoid valves, G1/8 port. Valve functions: x3/, 5/

More information

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. Getting Started This is a brief document designed to quickly get you started setting up your 2002 Series valve manifold with integrated Numatics G2-1\2 Profibus-DP communication protocol. Please note that

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Thermocouple Elements BLCEN-8M12LT-4AI-TC-4AI-TC On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

Technical Data. General specifications. Output type Rated operating distance s n 8 mm Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone 2 and zone 22 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications

More information

11 PROFIBUS Fieldbus Connector

11 PROFIBUS Fieldbus Connector 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm 5 < 36,7mm < 372 mm < 54 mm < 36 mm / 42 in < 5-6 mm / 022 in < 0 mm / 0394 in The fieldbus connector links a PROFIBUS device

More information

G2-2 ControlNet 2005/2012 Series Technical Manual

G2-2 ControlNet 2005/2012 Series Technical Manual G2-2 ControlNet 2005/202 Series Technical Manual LT2005/202CNTECH- 0/03 www.numatics.com Table of Contents 2005/202 Series ControlNet Technical Manual PAGE About ControlNet... 3 Overview... 3 G2-2 ControlNet

More information

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications

Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Industrial Ethernet Panel-Mount Adaptors for PROFINET or EtherNet/IP Applications Type 0981 ENC 100 RJ45/M12 adaptor, female receptacle connector M12, D coding, chassis side thread PG 9, RJ45 female connector,

More information

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier. Getting Started This is a brief document designed to quickly get you started setting up your 200/2012 Series valve manifold with integrated Numatics G2-2 Profibus-DP communication protocol. Please note

More information

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling

01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling MATERIAL HANDLING MANIFOLDS WITH DeviceNet INTERFACE 01348(N or G) MH** -- Material Handling 01351(N or G) MH** -- Material Handling Note: N = NPT ports G = BSPP ports SOL 14 SOL 12 Station #3 SOL 14 SOL

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide...

Sensor Connectivity Introduction Global Plus Connector Cables Multi-Connector Blocks. Product Selection Guide... .0 Introduction Product Selection Guide.................................... Product Description....................................... Standards and Certifications................................ Product

More information

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017

RSTI-EP Slice I/O. PROFINET Scanner EPXPNS001. GFK-2965C November 2017 November 2017 Ethernet Ports PWR, SF, BF, MT, LINK 1, ACT 1, LINK 2, and ACT 2 LEDs Door for Micro USB Port PROFINET Scanner Power Supply LED RSTI-EP Slice I/O PROFINET Scanner The PROFINET Scanner is

More information

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Remote Process Actuation Control System AirLINE PHOENIX INLINE

Remote Process Actuation Control System AirLINE PHOENIX INLINE Remote Process Actuation Control System AirLINE PHOENIX INLINE Type 8644 can be combined with... Fully compatible with Phoenix Inline System Combination of Fieldbus, pilot valves and I/O modules High flexibility

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12

TM7NCOM16A CANopen interface block - IP67-16 I/O - M12 Characteristics CANopen interface block - IP67-16 I/O - M12 Main Range of product Product or component type Range compatibility Enclosure material Bus type [Ue] rated operational voltage Input/Output number

More information

PROFIBUS Fieldbus Connector 634

PROFIBUS Fieldbus Connector 634 750-960 PROFIBUS Fieldbus Connector 634 54 mm> < < 45mm < 36,7mm < 372 mm < 54 mm < 36 mm / 142 in < 5-6 mm / 022 in < 10 mm / 0394 in The fieldbus connector links a PROFIBUS

More information

SK CU4-EIP-C Part number:

SK CU4-EIP-C Part number: SK CU4-EIP-C Part number: 275 271 519 EtherNet/IP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

ACSI ACTUATOR CONTROL SOLUTIONS

ACSI ACTUATOR CONTROL SOLUTIONS ACSI ACTUATOR CONTROL SOLUTIONS INTEGRATED SERVO MOTOR / DRIVE / CONTROLLER LINEAR SOLUTIONS MADE EASY ACSI Motor/Drive/Controller WHAT IS THE ACSI? The ACSI is an extremely easy-to-use integrated servo

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8692 can be combined with Compact stainless steel design Graphic display with backlight Easy start-up Comprehensive

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps supported Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary

More information

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI

BL compact multiprotocol fieldbus station for Industrial Ethernet 8 Analog Inputs for Current or Voltage BLCEN-8M12LT-4AI-VI-4AI-VI On-machine Compact fieldbus I/O block EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet Switch 10 Mbps / 100 Mbps Two 4-pole M12, D-coded, connectors for fieldbus connection 2 rotary switches

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

Quick Start Manual G2-2 Series with Ethernet Interface

Quick Start Manual G2-2 Series with Ethernet Interface Getting Started This is a brief document designed to quickly get you started setting up your valve manifold with integrated G2-2 series EtherNet/IP communication protocol. 1) Initial Unpacking and Inspection

More information

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors

M8/M12 Connector. PCA/EX9/EX500 Series. Reduction in wiring time. Conforming to IEC Fieldwireable Connectors / Connector /EX9/EX00 Series Fieldwireable Connectors Reduction in wiring time The man-hours can be decreased because no exclusive tools (such as solder, crimped terminal) are required.also, the wire length

More information

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12 www.stahl.de > Fieldbus connection Industrial Ethernet PROFINET, Modbus TCP or EtherNet/IP with 100 MBit/s > Redundant Ethernet connection (Modbus TCP) is possible > Explosion protected, optical inherently

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

E1 Plus Electronic Overload Relay

E1 Plus Electronic Overload Relay ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION E1 Plus NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific installations

More information

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02 SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02 SPiiPlusEC Release Date: November2014 Copyright ACS Motion Control Ltd.2014. All rights reserved. Changes are periodically

More information

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings Features Multiturn SSI / Profibus / CANopen / DeviceNet / PROFINET Optical sensing method Singleturn 1 bit, multiturn 1 bit / 16 bit EURO-flange B10 / solid shaft ø11 mm Multiturn sensing with microgen

More information

S-series Electronic Marshalling

S-series Electronic Marshalling DeltaV Distributed Control System Product Data Sheet July 2017 S-series Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture

More information

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv)

Valve terminal RE-10 with Multi-pin, AS-Interface or bus connection 4 12 valve stations, 300 Nl/min (0.305 Cv) Type of connection = AS = B1 = B6 Order code RE-10/08-M-1-060 Series Number of stations Multi-pin: 4, 6, 8, 10, 12 Bus versions: 4, 8, 12 Electrical options M-1 = Multi-pin D-Sub plug AS3 = AS-Interface

More information

Digital electropneumatic Process Controller

Digital electropneumatic Process Controller Digital electropneumatic Process Controller Type 879 can be combined with Compact and robust design Easy Start-up using tune function of the Positioner and Process controller Integrated diagnostic functions

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications

New Product Bulletin. Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications New Product Bulletin PB 327 Lumberg Automation EtherNet/IP Modules for Industrial Automation Applications These 16 digital I/O channels with universal input/output functionality for direct connections

More information

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives

PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives PowerDRIVE-Box GEL 6505 Interface for controlling up to 5 positioning drives Technical information Version 208-05 GEL 6505A: Box for top hat rail mounting, IP 20 variant General The PowerDRIVE-Box GEL

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type 8695 can be combined with Compact stainless steel design Integrated analog valve position registration (Teach function) Coloured illuminated

More information

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

Valve island VM10 with EtherNet/IP Interface 8, 10, 12 or 16 stations. Operation & Service Manual

Valve island VM10 with EtherNet/IP Interface 8, 10, 12 or 16 stations. Operation & Service Manual Valve island VM10 with EtherNet/IP Interface 8, 10, 12 or 16 stations Operation & Service Manual Change history: The Change history reflects all changes of the, which were done after the initial release.

More information

Rotary Measuring Technology Absolute encoders, Multiturn, DeviceNet

Rotary Measuring Technology Absolute encoders, Multiturn, DeviceNet High IP High shaft load capacity Shock/vibration resistant Short-circuit proof Reverse polarity protection Compact and Rugged: Minimal installation depth High shock and vibration values Very compact (only

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled state Profibus

More information

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6 Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Control head for hygienic process valves

Control head for hygienic process valves for hygienic process valves Type can be combined with... Universal attachment for hygienic process valves Contactless position measurement system with 3 switching points (Teach-In function) Coloured status

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

Serial/Ethernet Converter

Serial/Ethernet Converter Serial/Ethernet Converter IE-CS-2TX-1RS232/485 IE-CST-2TX-1RS232/485 IE-CS-2TX-2RS232/485 IE-CST-2TX-2RS232/485 Hardware Installation Guide Second Edition, August 2016 1243440000/01/08.16 Please note:

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

CompactBlock Guard I/O EtherNet/IP Safety Modules

CompactBlock Guard I/O EtherNet/IP Safety Modules Installation Instructions CompactBlock Guard I/O EtherNet/IP Safety Modules Catalog Numbers 1791ES-IB8XOBV4, 1791ES-IB16 Topic Page Important User Information 2 North American Hazardous Location Approval

More information