97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

Size: px
Start display at page:

Download "97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT"

Transcription

1 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination DIN EN 6, DIN 33 and IEC 6 08 Valves for safety systems multi-channel up to SIL Crossover-free switching Add-on manual override Suited for outdoor use under critical environment conditions (see solenoid list) The solenoid valves are applicable in the protection classes Ex e mb, Ex d mb, Ex mb, Ex ia for zones & (gas), & (dust), ATEX cat. II GD International approvals: IEC Ex, FM, CSA others on request DIN EN 608 IEC 608 Approval depends on magnetic system, see pages, and 8! Technical features Medium: Filtered, non-lubricated and dried compressed air, instrument air, nitrogen and other non-flammable neutral, dry fluids Operation: Indirect solenoid operated spool valves Operating pressure:,... 8 bar with internal air supply bar with external air supply Orifice: DN 6 mm, DN 8 mm Port size: G/, / NPT, G/, / NPT Mounting position: Optional, impulse valves preferably horizontally Fluid/Ambient temperature: C (special NBR), C (HNBR) Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below + C. For outdoor installations must be protected all connections against the penetration of moisture and a solenoid with IP66 protection must be used! Materials: Body: aluminium 3.06 with surface treatment for rough environmantal conditions (condensate test with alternating temperatures in sulphuric environment, salt spray test with different sodium chloride solutions, tested in ammonia environment), brass.00 (Ms 8), stainless steel.0 ( L) Seals: special NBR or HNBR /3 00-8e N/en..8.0

2 70 Inline Technical data Valves with seals NBR C *3), housing: aluminium anodized 3 Test certificate IEC 608 *) Model *) G / 3/ Solenoid/spring,... 8 bar 0 x 0, 733 / NPT 3/ Solenoid/spring,... 8 bar 0 x 0, 73 G / 3/ Solenoid/spring,... 8 bar 600 0, 73 / NPT 3/ Solenoid/spring,... 8 bar 600 0, 7 G / / Solenoid/spring,... 8 bar 0 x 0, / NPT / Solenoid/spring,... 8 bar 0 x 0, G / / Solenoid/spring,... 8 bar 600 0,7 70 / NPT / Solenoid/spring,... 8 bar 600 0,7 706 G / / Solenoid/solenoid,... 8 bar 0 0,7 73 / NPT / Solenoid/solenoid,... 8 bar 0 0,7 7 G / /3 Solenoid/solenoid, APB,... 8 bar 0 0, / NPT /3 Solenoid/solenoid, APB,... 8 bar 0 0, Housing: brass 3 Test certificate IEC 608 *) Model *) G / 3/ Solenoid/spring,... 8 bar 0 x,0 73 / NPT 3/ Solenoid/spring,... 8 bar 0 x,0 7 G / 3/ Solenoid/spring,... 8 bar 600,0 7 / NPT 3/ Solenoid/spring,... 8 bar 600,0 76 G / / Solenoid/spring,... 8 bar 0 x, / NPT / Solenoid/spring,... 8 bar 0 x, G / / Solenoid/spring,... 8 bar 600,7 706 / NPT / Solenoid/spring,... 8 bar 600, G / / Solenoid/solenoid,... 8 bar 0,7 763 / NPT / Solenoid/solenoid,... 8 bar 0,7 76 Housing: stainless steel 3 Test certificate IEC 608 *) Model *) G / 3/ Solenoid/spring,... 8 bar 0 x, 7373 / NPT 3/ Solenoid/spring,... 8 bar 0 x, 737 G / 3/ Solenoid/spring,... 8 bar 600, 737 / NPT 3/ Solenoid/spring,... 8 bar 600, 7376 G / / Solenoid/spring,... 8 bar 0 x, / NPT / Solenoid/spring,... 8 bar 0 x, G / / Solenoid/spring,... 8 bar 600,8 707 / NPT / Solenoid/spring,... 8 bar 600, G / / Solenoid/solenoid,... 8 bar 0,8 773 / NPT / Solenoid/solenoid,... 8 bar 0,8 77 In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *) When ordering please indicate solenoid, voltage and current type (frequency) *) Since May 008, Date code A8 *3) For operation in plants according to IEC 6/ C see test certificate (on request) Valve function: APB = All Ports Blocked N/en e /3

3 70 Inline Valves with seals HNBR C *3), housing: aluminium anodized 3 Test certificate IEC 608 *) Model *) G / 3/ Solenoid/spring,... 8 bar 0 x 0, 733 / NPT 3/ Solenoid/spring,... 8 bar 0 x 0, 73 G / 3/ Solenoid/spring,... 8 bar 600 x 0, 73 / NPT 3/ Solenoid/spring,... 8 bar 600 x 0, 7 G / / Solenoid/spring,... 8 bar 0 x 0, / NPT / Solenoid/spring,... 8 bar 0 x 0, G / / Solenoid/spring,... 8 bar 600 x 0,7 70 / NPT / Solenoid/spring,... 8 bar 600 x 0,7 706 G / / Solenoid/solenoid,... 8 bar 0 0,7 73 / NPT / Solenoid/solenoid,... 8 bar 0 0,7 7 G / /3 Solenoid/solenoid, APB,... 8 bar 0 0, / NPT /3 Solenoid/solenoid, APB,... 8 bar 0 0, Housing: Brass 3 Test certificate IEC 608 *) Model *) G / 3/ Solenoid/spring,... 8 bar 0 x, / NPT 3/ Solenoid/spring,... 8 bar 0 x,0 733 G / 3/ Solenoid/spring,... 8 bar 600 x,0 733 / NPT 3/ Solenoid/spring,... 8 bar 600 x,0 73 G / / Solenoid/spring,... 8 bar 0 x, / NPT / Solenoid/spring,... 8 bar 0 x, G / / Solenoid/spring,... 8 bar 600 x,7 703 / NPT / Solenoid/spring,... 8 bar 600 x,7 70 G / / Solenoid/solenoid,... 8 bar 0,7 733 / NPT / Solenoid/solenoid,... 8 bar 0,7 73 Housing: Stainless steel 3 Test certificate IEC 608 *) Model *) G / 3/ Solenoid/spring,... 8 bar 0 x, 733 / NPT 3/ Solenoid/spring,... 8 bar 0 x, 73 G / 3/ Solenoid/spring,... 8 bar 600 x, 73 / NPT 3/ Solenoid/spring,... 8 bar 600 x, 7 G / / Solenoid/spring,... 8 bar 0 x, / NPT / Solenoid/spring,... 8 bar 0 x, G / / Solenoid/spring,... 8 bar 600 x,8 70 / NPT / Solenoid/spring,... 8 bar 600 x,8 706 G / / Solenoid/solenoid,... 8 bar 0,8 73 / NPT / Solenoid/solenoid,... 8 bar 0,8 7 In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *) When ordering please indicate solenoid, voltage and current type (frequency) *3) For operation in plants according to IEC 6/ C or C see test certificate (on request) Valve function: APB = All Ports Blocked /3 N/en..8.03

4 70 Inline Solenoid operators, standard voltages Stainless steel Power consumption V d.c. V a.c. (W) (VA) Rated current V d.c. V a.c. (m A) (m A),, *) 78 IP 6 (with connector) Connector DIN EN form A *), *6) 3,6 0 IIG IID,6 8 IIG IID 0,8 38 IIG IID,3 6 IIG IID 0,8 33 IIG IID 0,8 33 IIG IID,3 6 IIG IID,3 6 IIG IID 0,8 33 IIG IID,3 6 IIG IID Ex-Protection IP-Protection class (to EN 60) Ex-Protection (ATEX-Category) Ex mb IIC T Gb Ex mb IIIC T0 C Db IP 66 Ex mb IIC T Gb Ex mb IIIC T0 C Db IP 66 Ex e mb IIC T/T Gb Ex tb IIIC T C Db, Ex e mb IIC T/T Gb Ex tb IIIC T C Db, Ex d mb IIC T/T6 Gb Ex e mb IIC T/T6 Gb Ex tb IIIC T C Db Ex d mb IIC T/T6 Gb Ex e mb IIC T/T6 Gb Ex tb IIIC T C Db Ex d mb IIC T/T6 Gb Ex e mb IIC T/T6 Gb Ex tb IIIC T C Db Ex d mb IIC T/T6 Gb Ex e mb IIC T/T6 Gb Ex tb IIIC T C Db Ex mb d IIC T/T6 Gb Ex mb e II T/T6 Gb Ex td A T00 ) Ex mb d IIC T/T6 Gb Ex mb e II T/T6 Gb Ex td A T00 ), XP/DIP, Div. & Cl. I, Gr. A-D Cl. II / III, Gr. E-G T3 (60 C) NEMA, X, 6, 6P, 7, Temperature Ambient/Fluid Nr. Nr. 0,3 7 / Cable 3 m 0, Cable 3 m 0, T T T T T T T T T T T T T T T T Flying leads 0 mm M0 X, *6) 0, M0 X, *6) 0, / NPT *6) 0, M0 X, *6) 7 60 / NPT *6) 0, M0 X, *6) 0, M0 X, *6), 0 80 M0 X, *6), , Standard voltages (±0%) V d.c., V a.c., other voltages on request. Design according to VDE 080, EN 00/ % duty cycle. *) Required connector: type 0707 for d.c. and for a.c., to be ordered solenoid voltage 00 V d.c. *6) Connector cable gland not supplied, see table»accessories«attention: The protection class for coil series 6xx and 8xx is determined by the choice of cable gland. Example: if an ATEX-certified cable gland is used that has Ex d type of protection, the solenoid will have the protection class Ex d mb; if a cable gland with Ex e type of proteciton is used, the solenoid will have protection class Ex e mb. Approvals Model Approvals Datasheet ATEX IECEx FM 0x KEMA 0 ATEX 37 X N/en x, 38x CSA-LR N/en 7..7 xx KEMA 8 ATEX X IECEx KEM X N/en xx PTB 0 ATEX 08 X IECEx PTB.00X N/en xx PTB 06 ATEX 0 X IECEx PTB X N/en 7..0 ( C) Electrical connection Circuit diagram Model N/en e /3

5 70 Inline Solenoid actuators for intrinsically-safe circuits Nominal resistance RN coil (Ω) Cable gland is included in delivery Min. required switching current (ma) Resistance Rw 60 coil (Ω) Required voltage at terminal Rw 60 (V) IP-Protection class (to EN 60) Ex-Protection (ATEX-Category) Ex ia IIC T Ex ia IIC T Ex iad T80 C Ex iad T00 C Temperature Ambient/Fluid ( C) When selecting an intrinsically safe power supply, the permissible maximum values according to the Certificate of Conformity should be taken into account. Ui = V, Ii = 00 ma according to Tab. A., EN Pi =,0 W, Li and Ci can be ignored. Circuit diagram Model , , , , Approvals Model Approvals Datasheet ATEX IECEx FM 0x PTB 07 ATEX 0 IECEx PTB N/en 7..3 /3 N/en..8.0

6 70 Inline Valves, indirect solenoid operated using low-power pilot system in protection class Ex ia IIC T/T6, seals NBR C, housing: aluminium anodized, suitable solenoid operators see page 8 only 3 Model *) G / 3/ Solenoid/spring, , / NPT 3/ Solenoid/spring, , 7 73 G / 3/ Solenoid/spring, , 8 73 / NPT 3/ Solenoid/spring, , 8 7 G / / Solenoid/spring, ,7 703 / NPT / Solenoid/spring, ,7 70 G / / Solenoid/spring, , / NPT / Solenoid/spring, , G / / Solenoid/solenoid, ,7 73 / NPT / Solenoid/solenoid, ,7 7 G / /3 Solenoid/solenoid, APB, ,7 73 / NPT /3 Solenoid/solenoid, APB, ,7 7 3 Housing: Brass 3 Model *) G / 3/ Solenoid/spring,... 8 bar 0, / NPT 3/ Solenoid/spring,... 8 bar 0,0 7 7 G / 3/ Solenoid/spring,... 8 bar 600,0 8 7 / NPT 3/ Solenoid/spring,... 8 bar 600, G / / Solenoid/spring,... 8 bar 0, / NPT / Solenoid/spring,... 8 bar 0,7 706 G / / Solenoid/spring,... 8 bar 600, / NPT / Solenoid/spring,... 8 bar 600, G / / Solenoid/solenoid,... 8 bar 0,7 763 / NPT / Solenoid/solenoid,... 8 bar 0,7 76 Housing: Stainless steel 3 Model *) G / 3/ Solenoid/spring,... 8 bar 0, / NPT 3/ Solenoid/spring,... 8 bar 0, G / 3/ Solenoid/spring,... 8 bar 600, / NPT 3/ Solenoid/spring,... 8 bar 600, G / / Solenoid/spring,... 8 bar 0, / NPT / Solenoid/spring,... 8 bar 0,8 707 G / / Solenoid/spring,... 8 bar 600, / NPT / Solenoid/spring,... 8 bar 600, G / / Solenoid/solenoid,... 8 bar 0,8 773 / NPT / Solenoid/solenoid,... 8 bar 0,8 77 In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *) When ordering please indicate solenoid, voltage and electrical connection, see page 8 Valve function: APB = All Ports Blocked N/en e /3

7 70 Inline Valves, Indirect solenoid actuated using low-power pilot system in protection class Ex ia IIC T/T6, seals HNBR C, housing: aluminium anodized, suitable solenoid operators see page 8 only 3 Model *) G / 3/ Solenoid/spring, , / NPT 3/ Solenoid/spring, , 7 73 G / 3/ Solenoid/spring, , 8 73 / NPT 3/ Solenoid/spring, , 8 7 G / / Solenoid/spring, ,7 703 / NPT / Solenoid/spring, ,7 70 G / / Solenoid/spring, , / NPT / Solenoid/spring, , G / / Solenoid/solenoid, ,7 73 / NPT / Solenoid/solenoid, ,7 7 G / /3 Solenoid/solenoid, APB, ,7 73 / NPT /3 Solenoid/solenoid, APB, ,7 7 3 Housing: brass 3 Model *) G / 3/ Solenoid/spring,... 8 bar 0, / NPT 3/ Solenoid/spring,... 8 bar 0, G / 3/ Solenoid/spring,... 8 bar 600, / NPT 3/ Solenoid/spring,... 8 bar 600, G / / Solenoid/spring,... 8 bar 0, / NPT / Solenoid/spring,... 8 bar 0,7 703 G / / Solenoid/spring,... 8 bar 600, / NPT / Solenoid/spring,... 8 bar 600, G / / Solenoid/solenoid,... 8 bar 0,7 733 / NPT / Solenoid/solenoid,... 8 bar 0,7 73 Housing: stainless steel 3 Model *) G / 3/ Solenoid/spring,... 8 bar 0, / NPT 3/ Solenoid/spring,... 8 bar 0, 7 73 G / 3/ Solenoid/spring,... 8 bar 600, 8 73 / NPT 3/ Solenoid/spring,... 8 bar 600, 8 7 G / / Solenoid/spring,... 8 bar 0,8 703 / NPT / Solenoid/spring,... 8 bar 0,8 70 G / / Solenoid/spring,... 8 bar 600, / NPT / Solenoid/spring,... 8 bar 600, G / / Solenoid/solenoid,... 8 bar 0,8 73 / NPT / Solenoid/solenoid,... 8 bar 0,8 7 In order to ensure full flow and proper function make sure that sufficient pressure supply with feed pipe diameters according to the port size is available. *) When ordering please indicate solenoid, voltage and electrical connection, see page 8 Valve function: APB = All Ports Blocked /3 N/en..8.07

8 70 Inline Low-power pilot system in protection class Ex ia IIC T/T6 Suitable valves see page 6 and 7 only Power P (+0 C) Switch-on voltage U on (+0 C) Switch-on voltage U on (+80 C) Switch-off voltage U off (+0 C) Switch-off voltage U off (- C) Rated current I on Resistance coil R (+0 C) IP-Protection class (to EN 60) Ex-Protection (ATEX-Category) 6,3 mw,3 V, V, V, V, ma 800 Ω Ex ia IIC T IP 6 (with cable gland) 3, mw 6 V 6,8 V, V,7 V, ma 000 Ω Ex ia IIC T6 IP 6 (with cable gland) Temperature Ambient Circuit diagram Model C C 086 Max. values Ex i Ui (V) Ii (ma) Pi *) (mw) Air consumption: home position 60 l/h, operating position l/h *) Model 086 without Pi limiting. Ci and Li can be ignored. Ordering example Valve Pilot 6,3 mw Electrical connection 00 internal air supply Approvals 00 M6 x, cable gland 0Z external air supply Model Approvals Datasheet ATEX IECEx FM 08x PTB 06 ATEX 00U N/en 7..0 Option selector 7... Function Substitute / way valve with spring return 0 / way impuls /3 way valve with spring return (APB) 3/ way valve with spring return 3 Materials: Housing/Seals Substitute Aluminium/HNBR ( C)* Brass/HNBR ( C)* 3 Stainless steel/hnbr ( C)* Aluminium/NBR ( C)* Brass/NBR ( C)* 6 Stainless steel/nbr ( C)* 7 Port size Substitute G / 3 / NPT G / / NPT 6 Air supply Substitute Internal 0 External Z Voltage Substitute V d.c. 0.0 V a.c.. Solenoid Substitute See solenoid table Version Substitute Without manual override (retrofit) Semi automatic (on request) 7 low power pilot (see page 6 and 7) N/en e /3

9 70 Inline Accessories Cable gland Protection class Ex e, Ex d (ATEX), Nickel plated brass/ stainless steel Page Thread Cable Ø Material Protection class (ATEX) Model M 0x,,0...8,0 mm Nickel plated brass IIGD Ex e 0888 M 0x, 0... mm Nickel plated brass IIGD Ex d 0888 /--NPT 7,..., mm Nickel plated brass IIGD Ex d 088 M 0x,,0...3 mm Stainless steel.7 ( Ti) IIGD Ex e 0838 M 0x, 7,0... mm Stainless steel.0 ( L) IIGD Ex d 083 M 0x, 0... mm Stainless steel.0 ( L) IIGD Ex d Connector Silencer *) Exhaust guard *) Manual override) Page Page Page 0707 M/S (G/) 063 (G/, / NPT) (without detent) (with rectifier) C/S (/ NPT) 0633 (G/, / NPT) (with detent) M/S (G/) C/S (/ NPT) *) For indoors use only *) For outdoors use, opening pressure ~ 0, bar /3 N/en..8.0

10 70 Inline s Valves A A ~ 6 3 3, 3 ~ 0, ~78, 8, 3, 6,, , 3,, 3, 0,, ~8 3 63, 7 ~ , , A - A 0 Solenoid dimensions see page External control pressure connection G/8, /8 NPT 3 Working port G/, G/ or / NPT, / NPT Position of gasket internal pilot air 0 Position of gasket external pilot air N/en e /3

11 70 Inline A A 3 3 B, B A - A B - B 3 ~ , A - A B - B 0 ~ A A B B 0 70 Solenoid dimensions see page External control pressure connection G/8, /8 NPT 3 Working port G/, G/ or / NPT, / NPT Position of gasket internal pilot air 0 Position of gasket external pilot air /3 N/en..8.

12 70 Inline C C 3 3 3, 7 8, 3, 6, ~8 3, 3 3, 3, 3,, 3, 8 0,, , 7 c c 7, , 3, 3, 3 3 3, Electrical connection C-C 00 External control pressure connection G/8, /8 NPT int. P P ext. 3 Working port G/, G/ or / NPT, / NPT Electrical port M6x, 0 7 Position of gasket internal pilot air 0 Position of gasket external pilot air N/en e /3

13 70 Inline, C-C D-D 7 0 C C D D 3, 3 int. P 0 P ext. int. P P ext , C-C D-D ca C C ~ 3 3 D D 3 int. P 0 P ext. int. P P ext Electrical connection 00 External control pressure connection G/8, /8 NPT 3 Working port G/, G/ or / NPT, / NPT Electrical port M6x, 7 Position of gasket internal pilot air 0 Position of gasket external pilot air /3 N/en..8.3

14 70 Inline s Solenoid operators 3 3, 86, 0, / - NPT 0, , 6 3, 7 8, 8 M6 x, 8 33, 7 63, ,, 6, 7 0, 0, 3 M 0 x, Connector x 0 turnable Ø 3 (with spacer tube) 3 M0 x, or / - NPT Flying leads 0 mm long M0 x, 8 3 N/en e /3

15 70 Inline Circuit diagrams Silencer Model: M/S, M/S, C/S, C/S Exhaust guard Model: 063, 0633 C C G G ø D B ø D B B G C Ø D (g) Model G/ 7 3,,, M/S / NPT 7 3,,, C/S G/ 67 3, M/S / NPT 67 3, C/S B Suitable for G C Ø D (g) Model / G/, / NPT 0 6, 063 / G/, / NPT 33, 0633 Cable gland C B A D C B A D 088 only A B C ø D Model M0 x, M0 x, 6, 7, M0 x, /- NPT 8 7,..., 088 M0 x, M0 x, Manual override Model: Model: M0 x 0, Warning ~ These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in pneumatic systems and to provide adequate safeguards to prevent personal injury or damage to M0 x 0, ~ equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Functional safety (SIL): Suitable for certain applications can only be evaluated through examination of each safety-related overall system with regard to the requirements of IEC 608/6. /3 N/en..8.

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

Technical features. N/en

Technical features. N/en /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface For single and double operated actuators Exhaust air recirculation at way

More information

Technical features. 12/ f. N/en

Technical features. 12/ f. N/en /, / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT or flanged with NAMUR interface Main application: single and double operated actuators TÜV-approval based

More information

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves

97105 NAMUR, 3/2, 5/2 & 5/3 Indirect electromagnetic actuated spool valves 970 NAMUR, /, / & / > > Port size: / or / ISO G/NPT > > Main application: single and double operated actuators > > TÜV-approval based on type examination DIN EN, DIN 9 and IEC 08 > > Valves for safety

More information

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 975 Inline 3/-, 5/- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Closed crossover design Add-on manual override Rectified

More information

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7 90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators

More information

HERION SERIES Indirect solenoid actuated spool valves

HERION SERIES Indirect solenoid actuated spool valves HERION SERIES Indirect solenoid actuated spool valves for single and double acting actuators with NAMUR interface /2, /2, /, NC/APB, G/, G/2 Valves for safety systems up to SIL (IEC 08) Crossover-free

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / way spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple

More information

Operating pressure (bar)

Operating pressure (bar) / poppet valves electromagnetic actuated, directly controlled G /4, /4 NPT, G /, / NPT or flanged with NAMUR Interface Main application: single operated actuators for plants Valves for safety systems up

More information

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface

/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / way poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar

More information

Operating pressure. N/en/en

Operating pressure. N/en/en 660, 8007 NAMUR /, / & / spool valves electromagnetic actuated, indirectly controlled G / and NAMUR interface For single and double operated actuators Manual override with and without detent Simple design

More information

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to

More information

Flow. Flow. N/en

Flow. Flow. N/en / poppet valves electromagnetic actuated, directly controlled G /4 or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to, 0 - mbar For a.c. solenoid systems with integrated

More information

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT

97105 Inline direct pneumatically actuated 3/2 and 5/2 spool valves G 1/4.G1/2, 1/4 NPT 1/2 NPT direct pneumatically actuated 3/ and 5/ spool valves G /.G/, / NPT / NPT For single and double operated actuators Valves for safety systems up to SIL () Crossover-free switching, switch-over function guaranteed

More information

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Direct solenoid operated poppet valves Internal thread G /, / NPT or flanged with NAMUR interface Main application: single operated actuators for plants TÜV-approval based

More information

Material Seat seal. N/en

Material Seat seal. N/en 0 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR interface TÜV-approval based on IEC 6 8 Valves for safety systems up to SIL Standard NAMUR type - redundancy:

More information

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves

97105 Inline, 3/2 & 5/2 Direct pneumatically actuated spool valves 9705 Inline, 3/ & 5/ > > : /... / (ISO G/NPT) > > Main application: single and double operated actuators > > Valves for safety systems multi-channel up to SIL 3 > > Crossover-free switching > > TÜV-approval

More information

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve 9700 NAMUR series, / & / > > Port size: /4 (ISO G or NPT), NAMUR Interface > > Crossover-free switching > > Main application: Single and double acting actuators > > / way valve usable as / way valve >

More information

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface

3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface 9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V Valves for safety systems up to SIL Solenoid valve also

More information

80265 series, 3/2 Indirect solenoid actuated poppet valve

80265 series, 3/2 Indirect solenoid actuated poppet valve > > Port size: G/... G > > High flow rate > > Optionally air pilot operated > > High repeatability of switching time > > Variable valve solenoid combination Technical features Medium: Compressed air, filtered,

More information

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2. 66, 87 Inline / and 5/ directional control valves NG 6 and Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G /4 and G / For single and double operated actuators Manual

More information

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves

95100, 2/2 (stainless steel) Direct solenoid actuated poppet valves 9500, / (stainless steel) > > Port size: G/8, G/4, /4 NPT > > Working from 0 bar up > > Assembled free of oil and grease > > Suited for fine vacuum down to,33 0 - mbar > > For a.c. solenoid systems with

More information

21023, 21025, 2/2 Direct solenoid actuated poppet valves

21023, 21025, 2/2 Direct solenoid actuated poppet valves 03, 05, / > > Port size: G/4, G/ > > Working from 0 bar up > > Suitable for mediumhigh vacuum down to.33 0 - mbar l/s > > Compact design > > Valves and solenoids are ATEX approved. Additional international

More information

24011 series, 3/2 Direct solenoid actuated poppet valve

24011 series, 3/2 Direct solenoid actuated poppet valve 0 series, / > Port size: / (ISO G or NPT), NAMUR Interface > Add-on manual override or inductive limit switches on request > Main application: Single and double acting actuators > TÜV-approval based on

More information

Series 95000, 2/2 Direct solenoid actuated poppet valve

Series 95000, 2/2 Direct solenoid actuated poppet valve > Port size: /4 (ISO G or NPT), G/ > Working from 0 bar up > Short switching times > Suited for fine vacuum down to,33 x 0 - mbar > For a.c. solenoid systems with integrated rectifier (40... 60 Hz) > Variable

More information

Flow. (l/min) (ms) N/en

Flow. (l/min) (ms) N/en 66, 87 Inline / & / spool valves electromagnetic actuated, indirectly controlled G / & G / For single and double operated actuators Manual override with and without detent imple design of soft seal spool

More information

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

6215L Inline & NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve L Inline & NMUR series, / & / > Port size: / (ISO /NPT) or flanged with NMUR interface > Suited for outdoor use under critical environment conditions (see solenoid list) > Variable valve solenoid combination

More information

26360, NAMUR. Technical data

26360, NAMUR. Technical data 66, 87 NAMUR /-, /- and / directional control valves Operation: elektromagnetic Indirectly controlled soft seal spool valves Port size: G/ NAMUR-Interface For single and double operated actuators Manual

More information

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves

26360, 80207, 3/2, 5/2 & 5/3 Indirect solenoid actuated spool valves 66, 87, /, 5/ & 5/ > > Port size: G/ & G/ > > Compact design > > Easily interchangeable solenoid > > tandard manual override > > ll valves available with Ex protected coils (TEX or other international

More information

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V88 series Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil

More information

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V87 series - Redundant valve manifold systems - Semi modular 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V87 series - Redundant valve manifold systems - Semi modular oo Safety, oo Availability and oo Safety and Availability > > Semi modular design - Herion valves > > Stainless steel visual status indicators

More information

G 1/2 30,5 A Brass NBR 0,8 3,

G 1/2 30,5 A Brass NBR 0,8 3, 4/2 way poppet valves electromagnetic actuated, directly controlled /4 & /2 Working from 0 bar up Suitable for vacuum range down.33 0-2 mbar l/s Protection class : IP 65, Ex em, Ex d TEX approved (see

More information

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability

V88 series Redundant valve manifold systems - Semi modular 2oo2 Availability oo Availability > > Semi modular design - Maxseal valves > > Stainless steel visual indicators and exhaust guards as standard > > able terminations inside coil housing > > International approvals > > Stainless

More information

98015 series, 3/2 Direct solenoid actuated poppet valve

98015 series, 3/2 Direct solenoid actuated poppet valve 90 series, / > Port size: / & / (ISO G/NPT), NAMUR Interface > Main application: Single acting actuators > TÜV-approval based on type eamination DGRL 9//EG and IE 0, multichannel up to SIL > Optional add-on

More information

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated

ICO3S - 2/2, 3/2 or 5/2 poppet valves Electromagnetically actuated, direct solenoid operated ICOS - /, / or / poppet valves > > Port size: /... / (ISO G / NPT) Namur or manifold > > Control of pneumatic or hydraulic operated equipment > > Direct acting solenoid valve > > High flow > > bar inlet

More information

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve

SCVA08, SCVA10, SCVA20 & SCVA32, 3/2 Solenoid actuated safety valve SCV0, SCV0, SCV & SCV, / > > Port size: /4, /, /4 and (ISO G, NPT) > > Range of sizes - DN, 0, and > > Redundant valve assembly, pneumatic self monitoring with integrated safety silencer > > Ensures safe

More information

21D Allfluid pressure switch, electromechanically actuated

21D Allfluid pressure switch, electromechanically actuated D > > 0,... 0, bar (0,... psi), G/, / NPT > > High accuracy > > High number of switching cycles > > Microswitch approved by UL and CSA > > Fixed or adjustable hysteresis > > Shock and vibration tested

More information

SPCH/ Big bottle blowing block

SPCH/ Big bottle blowing block > > Blowing block for linear and rotating blow moulding machines > > Digital position indicator - counter with four decade from 000.0 to 00.0 > > Best suited for PET bottles from 5 up to 30 litres (up

More information

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR - ATEX version (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR - TX version (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder

More information

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves

ISO*STAR (SXE, SXP) 5/2 & 5/3 Solenoid and pilot actuated glandless spool valves *STR (SX, SXP) / & / > > Sub-base mounted, 99- s, or > > Specially coated glandless spool and sleeve for long trouble-free life > > Integral flow regulators available on and s for cylinder speed control

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2

26230, Inline 3/2, 5/2 and 5/3 way soft seal spool valves electromagnetic actuated, indirectly controlled G 1/4, G 1/2 /, / and / way soft seal spool valves electromagnetic actuated, indirectly controlled /, / traight-through flow, high v-factor tandard manual override ompact design asily interchangeable solenoid system

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled

ICO4S 2/2, 3/2 or 5/2 poppet valves electromagnetic actuated, directly controlled ICO4S /, / or 5/ poppet valves > > Port size: /4... /4 (ISO G/NPT) or manifold version > > Reliable and long life, ideal for a one time installation > > Direct acting solenoid valve for the control of

More information

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1. Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG 9 1610 and 1700 Nl/min (1.636 and 1.728 Cv) Order code Series and function 1) Plug socket see page

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof

More information

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application. DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4 Products 5/2 Directional-control valve, single valve, electrical connection M8 (4 poles) 5/3 Directional-control valve, single valve, electrical

More information

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Pneumatic Control Unit for the integrated mounting on process valves

Pneumatic Control Unit for the integrated mounting on process valves Pneumatic Control Unit for the integrated mounting on process valves Type 890 can be combined with Compact design Pilot valve with high air flow rate Internal control air channel Optical position indicator

More information

SideControl Positioner

SideControl Positioner SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC

More information

60 series, 2/2 or 3/2 Ball valve

60 series, 2/2 or 3/2 Ball valve >> Port size: Rp/..., /... >> Ideally suited for most general purpose applications >> Easy installation, simple operation and maintenance free >> -way ball valves with actuator interface conforming to

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process s Type 8694 can be combined with Automatic teach function Contact-free position sensor Compact stainless steel design AS-Interface

More information

V03, V04 and V05 Series

V03, V04 and V05 Series V03, V04 and V05 Series / and 3/ Poppet Valves Electrically Actuated G 1 8, G 1 4, CNOMO and Interface Extensive range of power and orifice size options Removable coil Manifold rail for 1 to 0 valves Operating

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Inductive sensor NI3-EG08K-Y1-H1341

Inductive sensor NI3-EG08K-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M8 x 1 Stainless steel, 1.4427 SO DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR)

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341 ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Control Head for the integrated mounting on process valves

Control Head for the integrated mounting on process valves Control Head for the integrated mounting on process valves Type can be combined with Compact stainless steel design Integrated analogue valve position registration (Teach function) Coloured illuminated

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic on/off valves in safety-instrumented systems.

More information

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Series 3731 Type Electropneumatic Ex d Positioner with HART communication Series 3731 Type 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening angle 24 to

More information

Data Sheet T EN

Data Sheet T EN Data Sheet T 8384-4 EN Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300

More information

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner Series 3731 TROVIS SAFE 3731-3 Electropneumatic Ex d Positioner with HART communication Application Single-acting or double-acting Ex d positioner for attachment to pneumatic on/off valves in safety-instrumented

More information

Load Disconnect Switches and Motor Switches

Load Disconnect Switches and Motor Switches Load Disconnect Switches and Motor Switches 594 Load Disconnect Switches and Motor Switches Contents Load Disconnect Switches and Motor Switches Safety Switches made of Resin 10, 12/16, 16, 20, 25, 40,

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Digital electropneumatic Positioner for the integrated mounting on process control valves

Digital electropneumatic Positioner for the integrated mounting on process control valves Digital electropneumatic Positioner for the integrated mounting on process control valves Type 8696 can be combined with Digital smart positioner Automatic teach function Contact-free position sensor Compact

More information

RM/28000/M, ISO cylinder Magnetic piston, single acting

RM/28000/M, ISO cylinder Magnetic piston, single acting > > Ø 0... 5 mm > > Standard magnetic piston for full control system versatility > > Nose mounting nut and piston rod locknut as standard > > Conforming to ISO > > Optional port arrangement for compact

More information

SMC Australia New Zealand IECEx & ATEX Compliant solenoid valves Rev 1.0

SMC Australia New Zealand IECEx & ATEX Compliant solenoid valves Rev 1.0 Eplosion Proof 3, 5 port solenoid valves IECEX compliant solenoid valves for Australia and New Zealand VF1/3/5000 Series XAR4001, XAR4002, XAR4003 VP3/5/700 Series XAR4010, XAR4011, XAR4012 VFN2000/200

More information

BSP & HOSE Fittings M5, 1/8... 1

BSP & HOSE Fittings M5, 1/8... 1 SP & HOS Fittings M5, 1/8... 1 Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage All taper threads pre-coated with non-ptf based sealant Straight Adaptors

More information

KINAX WT720 absolute, programmable angular postion transmitter

KINAX WT720 absolute, programmable angular postion transmitter For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

NELES ND7000 DIGITAL VALVE CONTROLLER

NELES ND7000 DIGITAL VALVE CONTROLLER NELES ND7000 DIGITAL VALVE CONTROLLER Metso's Neles ND7000 is a digital valve controller designed to operate on all control valve actuators and in all industry areas. ND7000 is a reliable and future-proof

More information

M/60100/M, Slide units Magnet piston, double acting

M/60100/M, Slide units Magnet piston, double acting M/000/M, Slide units > > Ø 0... 0 mm > > High quality sliding bearings ensure long durable life and high guidance performance > > Easy to install-reduces costly design time > > Double piston rod provides

More information

Variable Area Flowmeter DATASHEET

Variable Area Flowmeter DATASHEET Variable Area Flowmeter DATASHEET JUNHO 0 Data sheet DS/A6/6EN Rev. I Models A600 & A600 Purgemaster SNAP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Series 3731 Type 3731-5 Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication Application Positioners for attachment to pneumatic control valves Rated travels from 3.6 to 200 mm Opening

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting

R./57100/M, R./57300/M, Roundline cylinder Magnetic piston, single acting R./700/M, R./700/M, Roundline cylinder > >... 0 mm > > Saves 0% space over the basic length of a corresponding ISO/ VDM cylinder > > Standard magnetic piston for full control system versatility > > Low

More information

3/2 5/2 SERIES 362/562

3/2 5/2 SERIES 362/562 Manual and Pilot Operated Spool Valves 6L Stainless Steel and Brass Bodies /4" to " NPT / / 6/6 Features Ideal for valve automation for the oil and gas market Reliable, robust design with high flow performance

More information

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication

Series 3730 Type Electropneumatic Positioner with PROFIBUS-PA communication Series 3730 Type 3730-4 Electropneumatic Positioner with PROFIBUS-PA communication Application Positioners for attachment to pneumatic control valves Valve travel from 3.6 to 300 mm Opening angle 24 to

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Threaded thermocouple Miniature design Model TC10-D

Threaded thermocouple Miniature design Model TC10-D Temperature Threaded thermocouple Miniature design Model TC10-D WIKA data sheet TE 65.04 for further approvals see page 2 Applications Machine building, plant and vessel construction Propulsion technology

More information